vs1 - اصلی
TRANSCRIPT
VESSEL SUPPORT FOR
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
5151
VS1
IPS-D-PI-130
2"(DN50) ~ 18"(DN450)VERTICAL PIPES
X
(TYP.)
EXISTING REINF. PAD
C V
ESSE
L
PIPE SIZE
NPS DN2"
3"
4"
6"
8"
10"
12" 300
250
200
80
50
A B C
510
455
405
(TYP.)X
150 330
255100 50
65
75
90
90
25
45
180
230
L
ANGLE
50X50X9
65X65X9
75X75X10
CLIP ANGLES FIELDWELD TO PIPE ONLY
16"
14"
300
350 90
100 610
535
18" 300 100 66090X90X11
355
285
320
230
265
70
110
150
190
90
D
470
420
370
285
335
75
125
180
230
100
B
L
75(TYP.)
D
C
STIFFENER
PLAN FOR TYPE "2","3" & "4"
MAX. LOAD (kg)
L=300 L=400 L=500TYPE 2
L=500L=400L=300TYPE 3
L=500L=400L=300TYPE 4
40
NOTE "3"BOLT CENTER
1000 800 600
1500 1200 1000 1900 1600 1300
10(TYP
.)
2-FOR SIZES AND LOADS LARGER THAN THOSEGIVEN IN THE TABLE, SPECIAL SUPPORTS SHALL BE USED.
DIMENSIONS & LOADS TABLE(NOTE "2")
A
PLATE
E ENOTE "5"
CLIP PLATE (TYP.)
F
F
45
85
75
85
75
80
55
65
80
55
X
PLAN FOR TYPE "1"
EXISTING REINF. PAD
300
X
25x25x6
150x70x6
T-100x11
20
MAX.M20 BOLT & NUTS.
3-BOLT HOLES DIA. SHALL BE 21mm , FOR
4-"L" DIMENSIONS OF 300mm ARE PREFERRED.
5-MINIMUM OF DIMENSION "E" IS 10mm.
X
(TYP.)
VESSEL SUPPORT FOR
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
5051
VS1
IPS-D-PI-130
2"(DN50) ~ 18"(DN450)VERTICAL PIPES
X
T-100x11
FOR 1/2"(DN15) ~ 1 1/2"(DN40)
TYPE "2"
4040
150
230
X
305
7575
4075
40
TYPE "3"
X
TYPE "1"
2550
2550
CLIP ANGLES FIELDWELD TO PIPE ONLY
40
150
40
150
CLIP ANGLES FIELDWELD TO PIPE ONLY
150
150
150
225
2-ALL PLATES SHALL BE 10mm THIKNESS,
NUT : ASTM A-563 BOLT : ASTM A-307 ANGLE : ASTM A-36 PLATE : ASTM A-283 GR.C
3-MATERIAL SHALL BE AS FOLLOWS:
150
TYPE "4"
40
150
380
4075
75150 280
40
X
2550
X
150x70x6
25x25x6
70
20X
NOTE "4"
NOTE "4"NOTE "4"
T : ASTM A-36
EXCEPT FOR SUPPORT TYPE "1" WHICH ARE SHOWN ON ITS DRAWING.
4-FOR LOADS TABLE SEE SHEET No. 51.
WELD TO PIPE ONLYCLIP ANGLES FIELD
X
X
X
FOR VERTICAL PIPES
5149
VG2
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
NOTES
IPS-D-PI-130
VESSEL GUIDE
VESS
EL
1 (TYP.)X
MIN. 350MAX. 500
CHANNEL
150x10
150x6
FLAT
330
278
172
92
ØD
50
80
100
150
200
250
30012"
10"
8"
6"
4"
3"
2"
DNNPS
PIPE SIZE
C L
X3
2
BOLT 2
EXISTING REINFORCING PAD
D/
NUT
T
HOLE DIA.1 GG
1/
5050
FLAT 1
PART 1 DETAILPIPE CLIP
PART 3 DETAIL
30
50
PART 2 DETAIL
P G S
18
24
36
30
30
24
24
15
20
40
30
30
20
20
165
315
62 105
118
245
224
390
475
190
1/
300
385
475
575
700
260
175
8
8
10
15
20
8
5
T DEVEL.LENGTH
BOLT 1
DIA.1HOLESIZE
M12x50
M24x130
M20x100
M20x90
M16x70
14
28
24
24
18
1
M12x250
M10x140
SIZE SIZE
BOLT 2
14
12
HOLEDIA.2 R
60
120FROM 2"(DN50)~12"(DN300)
P
F
1005030
0
400
HOLE DIA.2
HOLE DIA.2
60
80
100
140
200
240
400
MAX. LOADON GUIDE
(KG)
DISTANCE PIECE
E
SEE DETAIL "A"
EXIST. VESSEL
EXIST.
LOCK NUT
SBOLT 1
REINFORCING PAD
CHANNEL
LOCK NUT
SLIDING SECTION2
FIXED PLATEWASHER
DETAIL "A"
NUT
E
64
84
104
124
80
100
LMAX.MIN.366
368
372
372
366
362
360
216
218
222
222
216
212
210
ASTM A-283 GR.CASTM A-563ASTM A-307ASTM A-36ASTM A-283 GR.CASTM A-283 GR.C
::::::
WASHER NUT BOLT CHANNEL
RUN.3-PIPE SHALL BE FREE TO SLIDE IN VERTICAL
COORDINATED WITH VESSEL MANUFACTURER. MATERIAL OF REINFORCING PADS SHALL BE
2-DIMENSIONS, LOCATIONS AND TYPE OF
FLAT PLATE
4-MATERIALS SHALL BE AS FOLLOWS:
1-FOR GENERAL NOTES SEE SHEET No. 4.
F
100
: ASTM A-500DISTANCE PIECE
==
L
R
36
94
185
154
122
67
54
VESSEL GUIDE SUPPORT
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
4851
5-MATERIALS SHALL BE AS FOLLOWS: U-BOLT FLAT
VG1
IPS-D-PI-130
FOR VERTICAL PIPESFROM 2"(DN50)~12"(DN300)
10
U-BOLT(NOTE "2")
(NOTE "4")
Ød1
MAX. 500MIN. 350
X
X(TYP.)
(TYP.)
X
32
1
EXIST. VESSELEXISTING
10
C V
ESSE
L
L
QPQ
S
HOLE DIA.Ød2
ANGLE
PART 1 DETAIL
PART 2 DETAIL
MAX. 480MIN. 330
CHANNEL
B
PART 3 DETAIL
FLAT
2-FOR U-BOLT DETAILS REFER TO SHEET No. 47 TYPE "B".
3-DIMENSIONS, LOCATIONS AND TYPE OF MATERIAL OF REINFORCING PADS SHALL BE COORDINATED WITH VESSEL MANUFACTURER.
4-PIPE SHALL BE FREE TO SLIDE IN VERTICALRUN.
CHANNEL ANGLE NUT WASHER
PIPE SIZE
NPS DN
2"
3"
4"
6"
8"
10"
12" 300
250
200
150
100
80
50
Ød1
6
10
12
16
ANGLE
SIZE L
50x5
70x7
254
372
474
580
694
200
140
Ød2
19
14
12
8
S P Q
70
100
344
290
234
182
124
35
50
175
145
120
95
65
30
40
FLAT
LENGTHSIZE B
50x6
100x10
100
200
CHANNEL
50
100
MAX. LOADON GUIDE(Kg)
210
350
550
900
1400
100
80
REINFORCING PAD
40
EXIST. REINFORCING PAD
EXIST. VESSEL
NOTE "3"
::::::
ASTM A-36ASTM A-283 GR.CASTM A-36ASTM A-36ASTM A-563ASTM A-283 GR.C
L
E
E
50
100
U-BOLTS FOR CARBON STEEL PIPES
IPS-D-PI-130
1/2"(DN15)~24"(DN600)
NOTES
4751
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
U
d1
DIMENSIONS TABLE
3-MATERIALS SHALL BE AS FOLLOWS:
1-FOR GENERAL NOTES SEE SHEET No. 4.
2-"H" AND "L" HAVE BEEN CALCULATED BASED ON PLATE THICKNESS UP TO 10mm.
PIPESIZE
NPSLHR d2 K
H
L
TIGHTENED
SEE DETAIL
R
U-BOLT DETAIL TYPE "A" TYPE "B"
K
FREE TO SLIDE
K
Ø d2HOLE
MIN. MIN.
Ø d2HOLE
3"
2"
1/2"
3/4"
1"
11/2"
10"
8"
6"
4"
12"
14"
16"
18"
20"24"
100
150
200
40
25
20
15
50
80
600500
450
400
350
300
250 12
16
20
24
6
10
139
164
180
207
233
259
310
47
32
12
15
19
26
112
86
59
50
40
80
75
60
55
95
130
155
65
60
55
50
70
80
380
330
295
275
235
220
190 835
980
1060
1231
1353
1511
1771
317
245
147
167
189
221
677
546
385
190
220
236
267
293
321
372
85
70
50
55
60
65
155
130
95
d1DEVELO
P.
18.5
28
24
14
7
12
DN LENGTH
EXIST. STRUCTURE
WASHER(TYP.)
ROUND BAR : ASTM-A36NUTS : ASTM-A563
4-TYPE "A" U-BOLT IS REQUIRED WHEREIT IS NECESSARY TO HOLD THE PIPE IN ALLDIRECTIONNS.
5-TYPE "B" U-BOLT IS REQUIRED WHEREIT IS UNDESIRABLE TO RESTRICT LONGITUDINALMOVEMENT.
NOT TO GRIP PIPETO GRIP PIPENOTE "4" NOTE "5"
NUT
M6
M10
M12
M16
M24
M20
NUTLOCK NUT
ROUND BAR
6-EXIST. STRUCTURE THICKNESS TO BE CHECKEDFOR SUITABILITY PRIOR TO FIXING U-BOLT.
NOTE "6"
FULL THREA
DED
SLIDE SHOE FOR COLD INSULATION
IPS-D-PI-130
3"(DN80)~24"(DN600)
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
HORIZONTAL PIPES
S3
1-FOR GENERAL NOTES SEE SHEET No. 4.
INSULATIONMETAL COVER SHEET
OVER LAPPING OFTHE METAL COVERSHEET TO BE SEALD
1/2"(DN15)~2"(DN50)
SHEETMETAL COVER
PAD
OVER LAPPING OFTHE METAL COVERSHEET TOBE SEALD
INSULATION 2-THE SHOE LENGTH "L" DIM. SHALL BE DECIDED
45
100
LNOTE "2"
POLYURETHANE THK.HIGH DENSITY
SAME AS INSULATION THK.
PAD15
30
40
NOTE "2"L
STEEL PLATE DETAIL
Ø 5 HOLE WITH Ø 8 CONTERSUNK FOR 4X20 FLAT HEAD SELF TAPPING SCREW
NOTE "4"
5040
LSUPP. C
R
0
t
DETAIL OF PAD
Ø 5 HOLE
DEPENDING ON WIDTH OF SUPPORT.
FIXING OF PAD TO POLYURETHANE BEFOR3-ADHESIVE SHALL BE USED FOR TEMPORARY
FASTENING SCREWS.
4-BY SIX No. SCREWS FOR 1/2"(DN15) ~2"(DN50) AND WITH MIN. EIGHT SCREWS FORLARGER PIPE SIZE. PLATE TO BE FIXED ON HIGH DENSITY POLYURETANE SHOE.
5-PLATE MATERIAL ASTM A-283 GR C.
NOTE "3"
4651
ADHESIVE
ADHESIVENOTE "3"
NPS 4"2"1/2"~1 1/2"
DN 50PIPE SIZE
8" 10" 12"
MAX. LOAD (kg)t 4
500
PAD
SHEET TOBE SEALDTHE METAL COVEROVER LAPPING OF
THE METAL COVERSHEET TOBE SEALD
OVER LAPPING OF
SAME AS INSULATION THK.POLYURETHANE THK.HIGH DENSITY
ROD Ø10 MIN.
ROD Ø20 MIN.
3" 6"
80 100 15015~40 200 250 300
14" 16"
400350 600
24"
500450
18" 20"
6 8
900 1300 1700 2500 3200 4000 4800 5300 6000 6800 7500 9000
LOADS TABLE(NOTE "6")
POLYURETANE.STRENGTH 15kg/cm FOR HIGH DENSITYARE CALCULATED BASED ON THE COMPRESSION
6-ALL MAXIMUM LOAD & PLATE THICKNESS (t),
2
3
EXISTING SUPPORT
EXISTING SUPPORT
SLIDE SHOE H-150
IPS-D-PI-130
1/2"(DN15)~6"(DN150)
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
8"(DN200)~18"(DN450)
CS-PWHT,ALLOY & STAINLESS STEEL
S2
b
E
25 N
10
c
6(TYP.)
10
(TYP.)6
b
6
L
6
M
M=100:1/2"(DN15)~2"(DN50)
10
a
c
E
25 N
10
PAD
(TYP.)6
NOTE "3"
6
RIBSEE DETAIL
20"(DN500)~24"(DN600)
hDETAIL OF RIB
6
DETAIL OF PAD
t
0
R
Ø 6 HOLE
10
140X10
M=150:3"(DN75)~6"(DN150)
RIB SEE DETAIL
150
50 FOR 300 LONG SHOE
10
10150
b
25TYP.TYP.
TYP.
150
NOTE "5"
100 FOR 500 LONG SHOEL
NOTE "5"
100 FOR 500 LONG SHOE50 FOR 300 LONG SHOE L
NOTE "5"
3-PAD CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
4-"E"HAVE BEEN CALCULATED BASED ON PAD THK. "t", WHERE THICKNESS IS OVER THAN "t", ADJUST "E".
1-FOR GENERAL NOTES SEE SHEET No. 4.
2-ALL PIECES DIRECTLY WELDED TO PIPINGSHALL BE IN THE SAME MATERIAL OF PIPING.
6
PADNOTE "3"
25TYP.
a
a
PIPESIZE
DIM.
N
14"
(DN350)
12"
(DN300)
10"
(DN250)
h
(DN200)
8"
MATERIAL
RUN PIPEDES.
TEMP.
MEMBER
a
b
c
a
0TO
350
c
c
c
c
420TO
350
A 283 GR. C
MATERIAL TABLE
b
cA 283 GR. C
159- 155 154E
16"
(DN400)(DN450)
18"
(DN500)
20"
(DN600)
24"
152 156 171 167
180 280
110
203 229 254 305R
t
0
-
-
3
110 137
156
162
6
150
178
90
10
SEE NOTE "2"
SEE NOTE "2"
2"~6"
NOTE 6
120
(DN50~150)(DN50~150)
1/2"~11/2"
OF
6-PAD THICKNESS SHALL BE SAME AS PIPE THICKNESS MIN. 3.
SEE NOTE "2"
A 283 GR. Cc
b420TO
760
c
c
a
TYP.
C.S.,ALLOY &STAINLESS STEEL
SAME MAT.AS PIPE
TYP.
FOR 16"(DN400)AND 18"(DN450)
TYP.
TYP.
X
25TYP.
NOTE "3"
30~8411~24
4551
5-THE SHOE LENGHT "L" SHALL BE DEPENDEDON MAX. THERMAL DISPLACEMENT AS FOLLOWS:
510
L330
200+-100
MAX. THERMAL DISP.
-+
(TYP.)
(TYP.)
(TYP.)6
60 30
SLIDE SHOE H-100
IPS-D-PI-130
1/2"(DN15)~6"(DN150)
PIPESIZE
DIM.
N
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
8"(DN200)~18"(DN450)
14"
(DN350)
12"
(DN300)
10"
(DN250)
h
(DN200)
8"
CS-PWHT,ALLOY & STAINLESS STEEL
MATERIAL
PIPE
C.S.,ALLOY &
DES.TEMP.
MEMBER
a
b
c
a
0TO
350
c
c
c
c
420TO
350
A 283 GR. C
MATERIAL TABLE
S2
b
E
25 N
10
c
6
10
a
L
6
3-PAD CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
4-"E"HAVE BEEN CALCULATED BASED ON PAD THK. "t", WHERE THICKNESS IS OVER THAN "t", ADJUST "E".
1-FOR GENERAL NOTES SEE SHEET No. 4.
2-ALL PIECES DIRECTLY WELDED TO PIPINGSHALL BE IN THE SAME MATERIAL OF PIPING.
b
cA 283 GR. C
CUT FROM "T" ASTM A-36
100- 105 104E
16"
(DN400)(DN450)
18"
(DN500)
20"
(DN600)
24"
102 106 120 117
180 280
60
203 229 254 305R
t
0
10
a
c
E
25 N
10
PAD
(TYP.)6
NOTE "3"
6
RIBSEE DETAIL
20"(DN500)~24"(DN600)
hDETAIL OF RIB
6
DETAIL OF PAD
t
0
R
Ø 6 HOLE
SHAPE T-100X11
RIB SEE DETAIL
10010
10100
b
25TYP.TYP.
TYP.
-
11~24
3
100
110
-
137
106
162
6
150
178
90
10
SEE NOTE "2"
SEE NOTE "2"
100
NOTE "5"
FOR 16"(DN400)AND 18"(DN450)
NOTE "5"
L==
= =L
NOTE "5"
25TYP.
b
PADNOTE "3"
6
a
25TYP.
2"~6"
NOTE 6
120
30~84
(DN50~150)(DN50~150)
1/2"~11/2"
RUN
6-PAD THICKNESS SHALL BE SAME AS PIPE THICKNESS MIN. 3.
SEE NOTE "2"
A 283 GR. Cc
b SAME MAT.420TO
760
c
c
a
STAINLESS STEEL
AS PIPE
(TYP.)6
NOTE "3"
4451
OF
5-THE SHOE LENGHT "L" SHALL BE DEPENDEDON MAX. THERMAL DISPLACEMENT AS FOLLOWS:
510
L330
200+-100
MAX. THERMAL DISP.
-+
(TYP.) (TYP.)6
(TYP.)
(TYP.)6
60 30
SLIDE SHOE H-150
IPS-D-PI-130
1/2"(DN15)~6"(DN150)
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
8"(DN200)~18"(DN450)
CS-WITHOUT PWHT
S1
b
E
25 N
10
c
6(TYP.)
10
(TYP.)6
a
b
6
L
6
M
M=100:1/2"(DN15)~2"(DN50)
10
a
c
(TYP.)6
E
25 N
10
PADNOTE "3"
6(TYP.)
RIBSEE DETAIL
20"(DN500)~24"(DN600)
h
DETAIL OF RIB
6
DETAIL OF PAD
t
0
R
Ø 6 HOLE
10
140X10
M=150:3"(DN80)~6"(DN150)
RIB SEE DETAIL
150
50 FOR 300 LONG SHOE
10
10150
b
25TYP.TYP.
TYP.
150
NOTE "5"
100 FOR 500 LONG SHOEL
NOTE "5"
100 FOR 500 LONG SHOE50 FOR 300 LONG SHOE L
NOTE "5"
3-PAD CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
4-"E"HAVE BEEN CALCULATED BASED ON PAD THK. "t", WHERE THICKNESS IS OVER THAN "t", ADJUST "E".
1-FOR GENERAL NOTES SEE SHEET No. 4.
2-ALL PIECES DIRECTLY WELDED TO PIPINGSHALL BE IN THE SAME MATERIAL OF PIPING.
ON MAX. THERMAL DISPLACEMENT AS FOLLOWS:5-THE SHOE LENGHT "L" SHALL BE DEPENDED
+-
+-
PIPESIZE
DIM.
N
14"
(DN350)
12"
(DN300)
10"
(DN250)
h
(DN200)
8"MATERIAL
RUN PIPE
CARBONSTEELDES.
TEMP.
MEMBER
a
b
c
a
0TO
350
c
c
c
c
420TO
350
A 283 GR. C
A 283 GR. C
MATERIAL TABLE
b
c
159 155 154E
16"
(DN400)(DN450)
18"
(DN500)
20"
(DN600)
24"
152 156 171 167
180 280
120 110
254 305R
t
0
157
-
150
90
10
SEE NOTE 2
SEE NOTE 2
1/2"~6"
-
-
-
(DN15~150) OF
-
-
FOR 16"(DN400)AND 18"(DN450)
TYP.
TYP.
TYP.
TYP.
4351
(TYP.)6
L MAX. THERMAL DISP.330510 200
100
60 30 3060
SLIDE SHOE H-100
IPS-D-PI-130
1/2"(DN15)~6"(DN150)
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
8"(DN200)~18"(DN450)
CS-WITHOUT PWHT
S1
b
E
25 N
10
c
6(TYP.)
10
(TYP.)6
L
63-PAD CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
4-"E"HAVE BEEN CALCULATED BASED ON PAD THK. "t", WHERE THICKNESS IS OVER THAN "t", ADJUST "E".
1-FOR GENERAL NOTES SEE SHEET No. 4.
2-ALL PIECES DIRECTLY WELDED TO PIPINGSHALL BE IN THE SAME MATERIAL OF PIPING.
CUT FROM T-100x11
3060
10
a
c
(TYP.)6
E
25 N
10
PAD
(TYP.)6
NOTE "3"
6
RIBSEE DETAIL
20"(DN500)~24"(DN600)
h
DETAIL OF RIB
6
DETAIL OF PAD
t
0
R
Ø 6 HOLE
(ASTM A-36)
RIB SEE DETAIL
10010
10100
b
25TYP.TYP.
TYP.
100
NOTE "5"
FOR 16"(DN400)AND 18"(DN450)
NOTE "5"
L
==
= =L
NOTE "5"
PIPESIZE
DIM.
N
14"
(DN350)
12"
(DN300)
10"
(DN250)
h
(DN200)
8"MATERIAL
RUN PIPE
CARBONSTEELDES.
TEMP.
MEMBER
a
b
c
a
0TO
350
c
c
c
c
420TO
350
A 283 GR. C
MATERIAL TABLE
b
cA 283 GR. C
100 105 104E
16"
(DN400)(DN450)
18"
(DN500)
20"
(DN600)
24"
102 106 121 117
180 280
70 60
203 229 254 305R
t
0
100
110 137
107
-
162
150
178
90
10
SEE NOTE 2
SEE NOTE 2
1/2"~6"
-
-
-
(DN15~150) OF
-
-
4251
(TYP.)
ON MAX. THERMAL DISPLACEMENT AS FOLLOWS:5-THE SHOE LENGHT "L" SHALL BE DEPENDED
+-
+-
L MAX. THERMAL DISP.330510 200
100
60 30
PICK UP SUPPORT
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
PU1
1-FOR NOTES SEE SHEET No's. 4 & 40.
4151
(FABRICATION DETAILS)FOR HORIZONTAL PIPES
D
H
SECTION
SECTION
DETAILS OF PART 1
DETAILS OF PART 2
FLAT 50x6
A
A
FLAT 50x6
SECTION A-A
A D H FLAT50x6LEN.MAX.MAX.
MAX. LOAD (kg)
NPS DNSECTION
LOAD BEARINGPIPE SIZE
L=600 L=800 L=1000
1250
- -3" 80
L-40x4 20695
404"
6"
8"
10"
12"
14"
16"
18"
20"
24"
100
150
200
250
300
350
400
450
500
600
L-50x5
L-60x6
L-70x7
L-80x8
L-100x10
50
100
170
260
500
50
30 20 100
60 40 100
70110
180
380
150
150
200
120
300
698
1155
1160
1165
1218
1220
1225
1228
1283
1288
50
60
100
70
80
710
1160
LOAD & DIMENSIONS TABLE
60
T-100x11
SECTION
1200
644
542
486
434
376
344
290
234
182
124
100
372
321
293
267
236
220
195
167
141
112
100
P K
B
B
SECTION B-B
==
200= =
P
K
PICK UP SUPPORT
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
PU1
1-FOR GENERAL NOTES SEE SHEET No. 4.
4051
3-FOR FABRICATION DETAILS SEE SHEET No. 41.
(ASSEMBLY)FOR HORIZONTAL PIPES
c) T : ASTM A-36
a) ANGLE : ASTM A-36 2-MATERIAL SHALL BE AS FOLLOWS:
LOAD BEARING PIPE SUPPORTED PIPEMAX. LOAD
L A
b) FLAT : ASTM A-283 GR-C
A L
X
LOAD BEARING PIPE
SUPPORTED PIPE
MAX. LOAD
L AA L
SHOE
X
SECTION
X
TYPE "A"FROM ADJACENT UNINSULATED PIPE
TYPE "B"FROM ADJACENT INSULATED PIPE
MAX. LOAD
MAX. LOAD
1
SECTION
2
(TYP.)
100
X
4-TO AVOID ROTATION OF SUPPORT, A TACKWELD BETWEEN LOAD BEARING PIPE AND
U-BOLT
T-100x11
(NOTES "4 & 5")
5-FOR U-BOLT DETAILS SEE SHEET No. 47TYPE "A".
U-BOLT SHALL BE USED.
ELEVATED PIPE SUPPORT
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
39
MISC.6(E.PS)
L
X
+150 FROM
S BY CIVILBY PIPING
H
EXIST. PAVING OR FOUNDATION
LOADING TABLE
ANCHOR BOLT (TYP.)(SHALL BE SUPPLIED BY CIVIL)
IPS-D-PI-130
800
1000 6000
600
400
TYPE
A
B
C
D
40150
200
NPS DNSCH.
6"
8"
10" 250
4" 100
MAX. VERTICALMAX. MAX.
(TYP.)
(TYP.)X
X(TYP.)
Ø6 WEEP HOLEPIPE
1800
2000
2100
H
51
6
W W1 2
L
135
185
235
295
180
230
280
335
W
W
1
2
Ø15 WEEP HOLE
MAX. LOAD
AA
FOR TYPE "D"HOLES ONLY CENTRE BOLT
HOLE DIA. Ø
Y Y
X
X
BASE PLATE DETAIL
A
A
= =
==
B
B
(TYP.)SEE DET. "E"
10
FOR TYPES "A","B" & "C"SECTION A-A
30°
30°
50
DETAIL "E"
(TYP.)SEE DET. "E"
10
FOR TYPE "D"
= =
60
250
SECTION A-A
28
22
18
DIA.TYPE
A
B
C
D
10
15
20
30
35
A B S
300
350
400 40 25
250
ANCHOR BOLT
M16x160
M16x185
M24x260
FABRICATION TABLELOAD(Kg)
3000
5000
6000
900
50
X
(SECTION AND DETAILS)
END CAP
PIPELOAD(Kg)
MAX. AXIAL
PAVING
200
140
100Ø
HOLE
(NOTE "3")
20
INCREASE SUPPORT LOAD CARRYING CAPACITY.
3-ALL MAXIMUM LOADS ARE CALCULATED BASEDON THE MAXIMUM DIMENSIONS "H" AND "L" GIVEN IN THE TABLE, SO A REDUCTION IN EACH OF THE ABOVE DIMENSIONS WILL
PLATE : ASTM A283-GR.CPIPE : API 5L-GR.B
2-MATERIAL SHALL BE AS FOLLOWS:
(TYP.)
(TYP.)
ELEVATED PIPE SUPPORT
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
38
MISC.6(E.PS)
L
X+150 FROM PAVING
S BY CIVILBY PIPING
H
EXIST. PAVING OR FOUNDATION
LOADING TABLE FOR TYPE "I"
ANCHOR BOLT (TYP.)(SHALL BE SUPPLIED BY CIVIL)
IPS-D-PI-130
6000
4000
3000
2000
L=1000TYPE
A
B
C
D
40150
200
NPS DNSCH.
6"
8"
10" 250
4" 100
MAX. VERTICAL LOAD(Kg)L=2000MAX.
150
(TYP.)
(TYP.)X
X(TYP.)
Ø15 WEEP HOLE
PIPE
2600
7500
10000
14000
H
7500
5200
3000
1000
51
PLAN
L
6mm.THICK.END CAP (TYP.)
2-FOR FABRICATION DETAILS SEE SHEET No.39.
MAX. LOAD
SIDE VIEW
3-FOR TYPE "II" THE MAXIMUM LOADS SHALL BE DOUBLED.
NOTE "3"
ENOTE "4"
4-DIMENSION "E" SHALL BE CALCULATED BYENGINEER DUE TO TEMPERATURE AND EXPANSION COEFFICIENT OF PIPELINE.
PIPE
SIDE VIEW
TYPE "I"
TYPE "II"
PIPE MAX. AXIALLOAD (kg)
5-MATERIAL SHALL BE AS FOLLOWS:PIPE : API 5L-GR.B
(TYP.)X
PLATE : ASTM A283-GR.C
800
500
1150
(NOTE "6")
EACH OF THE ABOVE DIMENSIONS WILL GIVEN IN THE TABLE, SO A REDUCTION IN ON THE MAXIMUM DIMENSIONS "H" AND "L"
6-ALL MAXIMUM LOADS ARE CALCULATED BASED
INCREASE SUPPORT LOAD CARRYING CAPACITY.
20
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
37
CONCRETE PIPE SUPPORT
5025
0TO CHANNEL AT 200 c/c
SECTION "B-B"
SUPPORT TYPE "B"
SECTION "A-A"
PLAN
MIN. 320
T-70 WITH Ø12mm HOLES200 C/C FOR Ø6mm STIRRUPS
Ø12 REINFORCING BARS
40(TYP.)
2001:2:4 CONC.
MIN. 20
0
LIFTING HOLES ONE AT EACHEND FROM 2" SCRAP PIPE"A"
"A"
1-FOR GENERAL NOTES SEE SHEET No. 4.
==
300
300
300
150
150
MAX. 1800
ELEVATION
MIN. 20
0
MAX. 1500 4040
MIN. 32
0
ELEVATION
90 75
"B"
"B"
275
LIFTING HOLES ONE AT EACH END FROMØ 2" SCRAP PIPE
Ø 10 STIRRUPS TO BE WELDED-100 CHANNEL
REINFORCING BARS Ø 12
(TYP.)
MISC.5(C.PS)
2-CONCRETE TO BE OF 1:2:4 MIX WITH MINIMUM CUBE OF 210 Kg/cm3 CRUSHING STRENGTH AT 28 DAYS.
3-THE SHAPES OF REFERED MK ARE AS FOLLOWS:
MKa
MKb
MKa
MKb
51
SUPPORT TYPE "A"
PLAN
300
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
3651
2-MATERIAL SHALL BE AS FOLLOWS:a) SECTION : ASTM A-36b) PLATE : ASTM A-283 GR.C c) NUT : ASTM A-563
B
B
==
==
A
A
SECTION A-A
L
SECTIONREINFORCING PLATE
(TYP.)
X
LOCK NUT
NUT
+150 FROM
S
TYPE SECTION
A
B
C
D
IPE-100
HEA-100
HEA-140
HEA-200
1810
15
20
30
35
A B S
250
350
450 40 25
200 30
HOLEDIA.
22
28
28
REINF.PLATETHK.
6
6
8
10
ANCHOR BOLT
M16x160
M18x185
M24x260
M24x260
BY CIVILBY PIPING
X
X
YY
HOLE DIA.
MAX. LOAD
PIPING SUPPORT DESIGNER.
MAX.800
X
CENTRE BOLT HOLESONLY FOR TYPE "D"
H
EXIST. PAVING OR COLUMN
ANCHOR BOLT (TYP.)(SHALL BE SUPPLIED BY CIVIL)
IPS-D-PI-130
(TYP.)
(TYP.)
A A
FIXED ENDED "T" POST
KMAX.800
(TYP.)
X
MISC.4(P1)
H=1000TYPE SECTION
A
B
C
IPE-100
HEA-100
HEA-140
D HEA-200
H=2000 H=3000 H=4000 H=5000
200
1000
2000
4500
100
500
1000
2500 1700
720
350
- -
260
550
1200
-
-
1000
400
FABRICATION TABLE
LOADING TABLEMAX. LOAD (Kg)
(Kgm)MAX.Mx My
MAX.(Kgm)
300
700
1500
3800
60
300
600
1100
COEFFICIENT IS 0.3.MOMENT ON AXIS "Y" AND FRICTION
(NOTE "4")
E
55
100
140
200
50
6 E
DETAIL "1"
X(TYP.)
SEE DETAIL "1"FLAT 50x6
PAVING
4-SPECIFIED LOAD ARE BASED ON LIMIT OF
3-DIMENSIONS "L" & "K" TO BE DEFINED BY
TYPEPIPE SIZE
"F" "L" "X" "Y"
400
450
285
311
300
310
580
600
"B"
"C" 200
200
200
"C"
"C"
"B"
"B"
"B"
500
600
650
700
750
320
375
394
419
441
320
330
340
340
350
610
640
650
660
680
130
130
130
130
"C"
490
510
520
550
560
570
590
TABLE-1
DN
2
CLC
TYP.
25 25
R.=32
R.=13
73 79
4687
133
X
64Y
152
PLAN
STUD BOLT
90 90
M27 0
M27x3 COARSE THREAD
R.=13
29Ø
6
IDENTIFICATION LETTER
25
R.=13
B
RAISED IDENTIFICATION LETTERFOR TYPE "B" OR "C"
SEE END DETAILFOR TYPE "B" AND "C"
B
38
SECTION C-C (TYPICAL) END VIEW
WEDGES AND STUD-TYPE "B"AND"C"
CL BOLT HOLE
FOR PULSATING COMPRESSOR PIPING
5135
MISC.3(DDS)
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
NOTES
IPS-D-PI-130
DROPDOWN SUPPORT-TYPE "B" & "C"
1-FOR NOTES SEE SHEET No's. 4 & 33.
C
(FABRICATION DETAILS)
NPS
30"
28"
26"
24"
20"
18"
16"
DN
TABLE-1
370
360
350
340
320
310
"C"
440
430
420
410
390
380
230
230
220
220
210
200
219
206
184
159
140
114
350
300
250
200
100
"A"
"A"
"A"
"A"
"A"
"A"
"X""L""F"PIPE SIZE
TYPE
150
PULSATING COMPRESSOR PIPING
5134
MISC.3(DDS)
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
NOTES
IPS-D-PI-130
DROPDOWN SUPPORT-TYPE "A" FOR
1-FOR NOTES SEE SHEET No's. 4 & 33.
86
8489
54
52
3
44
7070
M20x2.5 COARSE THREAD
M20 0 STUD BOLT
2525
67117 44
3
AA
220
45
11
272
C BOLT HOLEL
R.=22
220
38
27
LETTER
2
88
11
FOR TYPE "A"SEE TYP. END DETAIL
RAISED IDENTIFICATION LETTER
PLAN
RAISED IDENTIFICATION LETTER
SEE TYP. END DETAILFOR TYPE "A"
SECTION A-A
TYPICAL END DETAILWEDGES AND STUD-TYPE "A"
SECTION B-B
X
64
127
5275
8984
CL
VIEW "A"
BA
IDENTIFICATION IDENTIFICATIONLETTER
A B
3 3
NPS
6"
4"
8"
10"
12"
14"
(FABRICATION DETAILS)
C BOLT HOLEL"A" "A"
PULSATING COMPRESSOR PIPING
5133
MISC.3(DDS)
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
NOTES
IPS-D-PI-130
DROPDOWN SUPPORT FORADJUSTABLE WEDGES
LC OF PIPE
FDN.
USE TYPE "1C" FOR SIZES 26"(DN650) THRU 30"(DN750) PIPESUSE TYPE "1B" FOR SIZES 16"(DN400) THRU 24"(DN600) PIPESUSE TYPE "1A" FOR SIZES 4"(DN100) THRU14"( DN350) PIPESADJUSTING WEDGE SEE DETAIL ON SHEET No's. 34 & 35.
B
C
WITH WEDGE IN PLACEWITH BASE PLATE)WELD FLAT BAR GUIDE(FURNISHED
13
FBASE PLATE
TYPICAL WEDGE INSTALLATION
LC ELEVATION
L(MIN.)
TO BASE PLATEANCHOR BOLTS WELDED
OF PIPECL
LC
3(TYP.)CLEARANCE
(TYP.)
FOR TYPE"1B"
FOR TYPE"1C"
FOR TYPE"1A"
FRONT VIEW SIDE VIEW
123
136
206
AS PART OF THIS SHEET).GROUTING, BASE PLATE,ETC.)WILL NOT BE FURNISHED
5- ITEMS SHOWN IN PHANTOM LINE (ANCHOR BOLTS,
WITH THE IDENTIFICATION LETTERS STAMPED ON IT.4.3- WEDGES MAY BE CAST STEEL OR MILD STEEL
4.2- NUTS: ASTM. A-194 GRADE 2H.CLASS 3B FIT.
4.1- BOLTS: ASTM. A-193 GRADE B7.CLASS 3A THREAD.
4- FABRICATION NOTES:
TYPE "HD-1" GUIDE HOLDDOWNS AS SHOWN ON 3- FOR PIPING SIZES 3"(DN80) AND UNDER USE
CYLINDER, SEE SHEET No. 31.
4"(DN100) THRU 30"(DN750), IF THERMAL EXPANSION USED AS ANCHORS ON PIPE OR BOTTLES FOR SIZES TEMPERATURE. TYPE "HD" HOLDDOWN GUIDES MAY BE TO BE MADE WHEN THE LINE REACHES OPERATING
4"(DN100) THRU 30"(DN750) FINAL ADJUSTMENT SUPPORT AS SHOWN IN TABLE-1&2 FOR PIPE SIZES
CYLINDER USE WEDGE TYPE "1A","1B" OR "1C" DAMPENERS DIRECTLY BELOW THE COMPRESSOR 2- FOR LINES VOLUME BOTTLES OR PULSATION
EFFECTS WILL NOT DAMAGE THE COMPRESSOR
FOR GENERAL NOTES SEE SHEET No. 4.1-
SHEET No. 31.
6- FOR FABRICATION DETAILS SEE SHEET No's. 34 & 35.
SEE DETAIL
(ASSEMBLY)
7- FOR DIMENSIONS "C","F" & "L"SEE SHEET No'S. 34 & 35.
X
1- FOR NOTES SEE SHEET No's. 4 & 31.
PULSATING COMPRESSOR PIPING
5132
MISC.2(HD)
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
NOTES
IPS-D-PI-130
HOLD-DOWNS TYPE "3 & 4"FOR
*
SEE NOTE 6
SEE NOTE 6
SPECIAL HOLD-DOWN FOR
USE ONLY WITH APPROVAL
COLD INSULATION
A
120A
CRADLE
FLAT WASHER COMPRESSION WASHERS AND
FLAT WASHER
TEMPERATURE RANGE : 40 C TO 340 C
" "TYPE HD.3 PIPE 12"(DN300) THRU 18"(DN450)
SIDE VIEW
PIER
CL
[ 180
COMPRESSIONWASHERS
DN550 580 630 680 300 350 400 450
A
SIZEPIPE
FRONT VIEW
1/2 IPB 260
WASHERCOMPRESSION
TEMPERATURE RANGE : 40 C TO 340 C
" "TYPE HD.4 PIPE 20"(DN500) THRU 36"(DN900)
SIDE VIEWFRONT VIEW
FLAT WASHER
*
*
PIPE SEE INSTALLATION AND WEAR PLATE FOR THIN WALL
DNPIPESIZE
A500 600 750 900 740 880 910 1070
FABRICATION DETAILS
COLD INSULATED LINES
NPS 12" 14" 16" 18"
NPS 20" 24" 30" 36"
LC
NOTE "7"
[ 100(TYP.)
[ 100(TYP.)
100
100(TYP.)
NOTE "7"
L 340 370 420 470 K 40
M12STUD BOLTSIZE
L 530 635 K 40
STUD BOLT M12SIZE
1020 1170
PIER
STUD BOLT DETAIL
L
KK
SHEET No.31
SHEET No. 31
X(TYP.)
(TYP.)X
1- FOR GENERAL NOTES SEE SHEET No. 4.
1/2
CIVIL ENGINEER.6- ANCHORE BAR REQUIRMENT SHALL BE SPECIFIED BY
SEE NOTE 6
SEE NOTE 6
A
USE TYPE HD.3 HOLD-DOWN (168)+(2x76)+(2x3)=326 mm. EXAMPLE:6"(DN 150) PIPE, 76 IC,3 CRADLE = (PIPE OD.)+(2xIC THK.)+(2xCRADELE THK.) HOLD-DOWN SIZE=
A
1/4300 900 503
177 40 80
AT WASHERS (kg)ACTUAL LOAD
NO.TURNSLINE SIZE
5- SIZING COLD INSULATED PIPE HOLD-DOWN:
ADDITIONAL NUMBER OF TURNS INDICATED IN CHART4.3 TURN NUT AT COMPRESSION WASHERS THE
4.2 TIGHTEN ALL NUTS BY HAND (FINGER TIGHT)
4.1 FOR ALL INSULATED AND UNINSULATED LINES.
4- FIELD PROCEDURE FOR TIGHTENING BOLTS:
SPECIAL DETAIL SHALL BE GIVEN FOR INDIVIDUAL 3.3 STEAM OR ELECTRIC TRACED LINES:
SEE SPECIAL HOLD-DOWN ON SHEET No. 32.3.2 COLD INSULATION:
(INSULATOR WILL NOT INSULATE THIS AREA). HOLD-DOWN SHALL BE INSTALLED ON BARE PIPE 3.1 HOT AND SAFTEY INSULATION:
BE AS FOLLOWS:3- HOLD-DOWN APPLICATION FOR INSULATED LINES SHALL
PIPING AT GRADE ON CONCRETE SLEEPERS. HOLD- DOWNS FOR RECIPROCATING COMPRESSOR2- THIS DRAWING SPECIFIES TYPE AND APPLICATION OF
WASHERSCOMPRESSION
[ 180
LC
PIER
" "
SIDE VIEW
TEMPERATURE RANGE : 40 C TO 340 C
TYPE HD.2 PIPE 4"(DN100) THRU 10"(DN250)
FRONT VIEW
FLAT WASHER
PIPESIZE
A100 150 200 250 310 360 410 450
DN
DN
USE ONLY WITH APPROVAL FROM STRESSTEMPERATURE RANGE : 40 C TO 340 C
" "TYPE HD.1 PIPE 3/4"(DN20) THRU 3"(DN80)
SIDE VIEWFRONT VIEW
130 130 150 160 19020 25 40 50 80
A
SIZEPIPE
PIER
L 75x75x7 (TYP.)
WASHERCOMPRESSION
FLAT WASHER
FOR PULSATING COMPRESSOR PIPING
5131
MISC.2(HD)
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
NOTES
IPS-D-PI-130
HOLD-DOWNS TYPE "1 & 2"
HD.2 4"(DN100)
4"(DN
100)
EXAMPLE TYPICAL DRAWING SYMBOLS
ARRANGEMENT DRAWING SPOOL DRAWING
HD.2 4"(DN 100)
(EXAMPLE) (EXAMPLE)
CL
3/4" 1" 1 /2" 2" 3"NPS
4" 6" 8" 10" NPS
NPS DN
1/2" 3"
12" 36"
4" 10" 100 250 1/4 252
1
.-.
.-.
.-.
.-.
.-.
.-.
1
PROJECT.
7-ACCORDING TO HEIGHT OF COMPRESSION WASHERS, THE THREAD LENGTH (K) AND STUD LENGTH (L) SHALL BE CORRECTED.
NOTE "7"
L 80 85 100 110 140
K 25
M6STUD BOLTSIZE
NOTE "7"
100
[ 80(TYP.)
L 125 180 230 285 K
STUD BOLTSIZE M10
35
STUD BOLT DETAIL
L
KK
X
X(TYP.)
50
LINE OR VOLUME BOTTLE
E
DC
MIN.MIN.= =
B
MIN.MIN.A
SPRING COMPRESSEDINSTALLATION AS REQD.
DIMENSIONS
A B C D E
LINE OR BOTTLESIZE
DN
160 165 115 180 43
160 205 135 210 45
160 290 200 275 60
240
240
240
330 215 290 60
380 240 370 64
445 270 64395
240 495 290 420 64
3-FABRICATION DRAWINGS, ( INCLUDING
RATE, STUD DIAMETER ETC.) SHOULD BE
13mm. SQUARE BARS AND BASE PLATEFURNISHED WITH FOUNDATION
2-USE ADJUSTABLE SPRING WEDGES WHERE
PULSATING LINES, VOLUME BOTTLES AND
150 ~ 200
50 ~ 100
250 ~ 350
400 ~ 500
600 ~ 800
850 ~ 1150
1200 ~ 1500
1-FOR GENERAL NOTES SEE SHEET No. 4.
PREPARED AT DETAIL DESIGN STAGE.
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IPS-D-PI-13051
30
NOTES
ADJUSTABLE SPRING WEDGESFOR PULSATING PIPING
REQUIRED BY VIBRATION ANALYSIS ON
PUMPS AND COMPRESSORS. PULSATION DAMPENERS AT RECIPROCATING
ADDITIONAL INFORMATION SUCH AS SPRING
4-FIGURES RELATED TO "MIN." SHALL CONFORM TO THOSE SPECIFIED IN PROJECT SPEC.
NOTE "5"
TO LINE CONDITION.5-DIMENSION "D" MAY BE ADJUSTED ACCORDING
MIN.
NPS
48"~60"
34"~46"
24"~32"
16"~20"
10"~14"
6"~8"
2"~4"
2
MISC.1(ASW)
(TYP.)
X(TYP.)
DATE SHEET REV.
DATEREV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
LINE STOP FOR HORIZ. HOT INSULATED PIPES
NOTES
1-FOR GENERAL NOTES SEE SHEET No. 4.
IPS-D-PI-130
LS2
29
51
(FABRICATION DETAILS)
T : ASTM-A36PLATE : ASTM-A283 GR.C
2-MATERIAL SHALL BE AS FOLLOWS:
MAX.
1400
1300
1200
1100
1000
FABRICATION TABLE OF DETAIL "F" & "G"
16212" 300 171 26350
14"
16"
18"
20"
24" 179
164
158
191
179
600
450
500
305
228
254
400
350
203
178
520
420
450
36
37
41
420
380
25
27
10"
8"
6"
4"
NPS
PIPE SIZEA
122
136
147
160
84150
250
200
136
110
100
DN
57
R
26210
300
260
24
26
160
B
24
C D
10
DETAIL "G"
10
10
10
8 159
8
8
144
138
10
10
8 171
8
8
159
151
S1D
D
10
=
DETAIL "F"
1126 8
8
8
8 138
8 125
6
S
6 98
1S 1D
== =
=
THICKNESS
CS 1=
S
A
10mm
R
= = =
=
= =
=
B
(TYP.)
1=
S C
X
70 FOR 2
"(DN50
)~3"(DN80
) 40
FOR 1/2"(DN15)~
1/2"(DN40
)
900
DETAIL "A"
= =
10
=
1
DATE SHEET REV.
DATEREV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
INSULATED PIPESLINE STOP FOR HORIZONTAL HOT
1/2"(DN15)~24"(DN600)
NOTES
IPS-D-PI-130
LS2
28
1-FOR GENERAL NOTES SEE SHEET No. 4.
51
2-MATERIAL OF PAD SHALL BE SAME AS PIPEMATERIAL. IT ALSO CAN BE MADE OF PIPESEGMENT INSTEAD OF PLATE.
SECTION
X
X 150
X
X
x
1/2"(DN15~3"(DN80)
PADNOTE "2"
4"(DN100)~24"(DN600)
(TYP.)
T-60x7 FOR 1/2"(DN15)~1 1/2"(DN40) T-100x11 FOR 2"(DN50)~3"(DN80)
PIPE SIZELOAD TABLE
NPS DN
1/2"~11/2" 15 ~ 40
1004"
6" 150
200 ~ 3008"~12"
350 ~ 45014"~18"
20" 500
MAX. AXIALLOAD (Kg)
10000
6000
3000
2000
200
24" 600
803"
2" 50T-100x11
HEA-100
HEA-140
HEA-200
HEA-240
HEA-260
T-60x7
250
==
SECTION EXIST. STRUCTURE
EXIST. STRUCTURE
SECTION
4-THE GAP BETWEEN STOP AND STRUCTURE
PADNOTE "2"
SHALL BE DETERMINED BY STRESS ANALYST.
STOP SECTION
NOTE "5"
NOTE "5"
X
x
(TYP.)
(TYP.)
SHEET No. 27.5-FOR PAD DETAIL AND DIMENSION TABLE SEE
NOTE "4"
NOTE "4"
3-MATERIAL SHALL BE AS FOLLOWS:PLATE : ASTM-A283 GR.CT : ASTM-A36
SEE DETAIL "A"
SEE DETAIL "G"
SEE DETAIL "F"
6-FOR FABRICATION DETAILS SEE SHEET No. 29.
50
5050
50
8000
800
LINE STOP FOR HORIZONTAL BARE PIPES
IPS-D-PI-130
NOTES
27
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
LS1
1-FOR GENERAL NOTES SEE SHEET No. 4.
DN
NPS PIPE SIZE
57
°
RS
DETAIL OF PAD
TABLE OF PAD
R
S
1/2"
15
3/4"
20 25
1"
401/2"
50
2"
80
3"1 4"
100
6"
150
8"
200
10"
250
12"
300
14"
350 400
16"
450
18"
500
20"
600
24"
84
5
110 136.5
150
6
162 178
8
203
10
228.6
120120
30 4511 13 17 24
3 4
254 305(FABRICATION DETAILS)
2
3-PLATE MATERIAL SHALL BE :ASTM-A283 GR.C
2
Ø6 VENT HOLE
51
2-THE LENGTH "E" SHALL BE SELECTEDDEPENDING ON WIDTH OF BEAM.
PIPE SIZE
450
500
600
20"
24"
18"
254
305
228
350
300
400
14"
16"
12"
203
178
162
27
26
25
41
37184
155
144
64
79
58
225
261
147
119
131
91
79
71
210
190
175
10
8
FABRICATION TABLE OF DETAIL "F" PIPE SIZE
6"
250
200
150
10"
8"
136
110
84
100
DN
4"
NPS
57
R
72
87
10460
47
36
150
128
103
5522
A B
80
C
8
24
6
D S
6
S1
C
B
SA
D 1S
R
3 3
600
500
450
20"
24"
18"
250
400
300
35014"
16"
12" 200
37450
522
41
25
26
27
420
380
350
10
250x8
100x10
250x10
8
DETAIL "G"
FABRICATION TABLE OF DETAIL "G"
6" 150
200
25010"
8"
100
DN
4"
NPS
150
F
24
300
256
206
8
160
H M
6
S2 III
250x6
250x6
100x6
100x8
250x8
6
3S I II
NOTE "2"
2 2
=
II
I
=
100
IIIM
250
DETAIL "F"
SF
C
B
S
SS M
H
E
S1 D SA
LINE STOP FOR
IPS-D-PI-130
1/2"(DN15)~24"(DN600)
NOTES
26
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
LS1
MATERIAL, IT ALSO CAN BE MADE OF PIPE2-MATERIAL OF PAD SHALL BE SAME AS PIPE
1-FOR GENERAL NOTES SEE SHEET No. 4.
HORIZONTAL BARE PIPES
3-PLATE MATERIAL SHALL BE :ASTM-A283 GR.C
51
100(TYP.)
X
1/2"(DN15)~3"(DN 80)
4"(DN100)~24"(DN600)
50
(TYP.)
X
6
150
X
(TYP.)X
150
EXISTING STRUCTURE
50
X
(TYP.)
EXISTING STRUCTURE
R=25
PADNOTE "2"
NOTE "2"PAD
X
X
X
(TYP.)
SEE DETAIL "G"
SEE DETAIL "F"NOTE "5"
NOTE "5"
X
500502"
3" 80
450 ~ 60018"~24"
150
2000
5000
6000
7000
LOAD (Kg)MAX. AXIAL
300 ~ 40012"~16"
10" 250
8" 200
1506"
4" 100
15 ~ 401/2"~11/2"
DNNPS
LOAD TABLE PIPE SIZE
4-THE GAP BETWEEN STOP AND STRUCTURESHALL BE DETERMINED BY STRESS ANALYST.
NOTE "4"
NOTE "4"
5-FOR FABRICATION DETAILS SEE SHEET No. 27.
SEGMENT INSTEAD OF PLATE.5050
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
2551
TYPE "B"FOR INSULATED PIPES
1- FOR GENERAL NOTES SEE SHEET No. 4.
2- MINIMUM LENGTH OF THREAD ENGAGEMENT EQUALS TO DIAMETER OF ROD.
HR2
PIPE CLIP
EYE NUT
EYE NUT
ROD
UPPER PIPELC
CL LOWER PIPE
SUPPORTED PIPE
PIPE CLIP
LOAD BEARING PIPE
MAX. LOAD
LOCK NUT(TYP.)
DISTANCE PIECE
3- TACK WELD OF ROD TO EYENUT SHALL BE DONE AFTER PIPE ELEVATION ADJUSTMENT IN OPERATION.
4- FOR FABRICATION DETAILS OF PIPE CLIP,EYE NUT AND ROD SEE SHEET No. 24.
6- LOAD BEARING PIPE (UPPER PIPE) SHALL BE CHECKED FOR ALLOWABLE STRESSES AND DEFLECTION.
HANGER SUPPORTPIPE TO PIPE
FOR UNINSULATED PIPES TYPE "A"
H
(TYP.)
3"(DN80) ~ 24"(DN600)
5- USE OF THESE SUPPORTS SHALL BE RESTRICTED TO SPECIAL CASES WHERE THE USE OF OTHER TYPES ARE IMPRACTICAL.
7- TYPE "B" SHALL ALSO BE USED FOR BARE PIPES ABOVE 100 °C.
MAX. LOAD
C
(TYP.)DISTANCE PIECE
LOWER PIPE
EYE NUT
PIPE CLIP
LC
H
ROD
PIPE CLIP
EYE NUT
UPPER PIPEL
LOCK NUT(TYP.)
LOAD BEARING PIPE
SUPPORTED PIPE
HANGER SUPPORT
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
HR1
1-FOR NOTES SEE SHEET No's. 4 & 23.
2451
FOR HORIZONTAL PIPES
PIPE SIZEID
PQ
G
DIMENSIONS TABLE
GG
P
B
ID
T
LOCK NUT
r=1.5T MIN.
BOLT
DISTANCE PIECE
CLIP DETAIL TYPE "A"
H2
HOLE DIA.
r=1.5T (TYP.)
H2
DISTANCE PIECE
BOLT
r=1.5T MIN.
LOCK NUT
T
ID
NUT
GP
GQ
r=1.5T (TYP.)
B
HOLE DIA.
CLIP DETAIL TYPE "B"
(TYP.)
DISTANCE PIECE
NPS DN TYPE"B"
TYPE"A"
B x T
TYPE TYPE"B""A"
TYPE"B"
TYPE"A"
H2
TYPE TYPE"B""A"
TYPE"A"
TYPE"B"
BOLT HOLE DIA.
TYPE"B""A"
TYPE
CLIP DIM.DEVELOPEDLENGTH
1/2"
1"
2"
3/4"
1 /2"1
3"
4"
6"
8"
10"
12"
14"
16"
18"
20"
24"
40
25
20
15
450
400
350
300
250
200
150
100
80
50
500
600 618
516
62
92
118
172
224
278
330
362
412
464
23
28
36
50
35x5
35x8
35x8
35x8
35x5
35x5
35x5
35x5
110x25
90x25
60x10
55x15
55x15
65x20
80x20
100x35
100x30
55x15
65x20
65x20
90x25
90x25
45x10
175
260
300
385
115
120
155
105
1280
1090
575
700
780
905
985
475 590
1090
975
880
790
685
1195
1415
175
240
190
180
480
395
355
250
70
75
95
65
80
95
95
95
70
70
85
70
90
115
95
54
45
45
36
30
54
63
15
18
15
15
24
24
24
18
30
12
15
15
15
10
10
12
10
33
29
17
20
24
24
29
17
830
715
190
245
305
365
455
500
575
635 660
600
525
475
390
315
740
880
105
165
24
12
15
12
12
19
19
19
15
42
35
35
28
24
42
48
80
M10x45
M12x50
M10x45
M10x45
M16x65
M16x65
M16x65
M12x50
140
130
120
100
150
170
M20x
M24x
M30x
M30x
M36x
M36x
M42x M42x
M36x
M36x
M30x
M30x
M24x
M20xM20x80
180
160
110
130
140
150
90
(CLIPS FABRICATION DETAILS)
FOR UNINSULATED PIPES FOR INSULATED PIPES
(TYP.)
(NOTE "3")
(NOTE "2" &"4")
(TYP.)
(NOTE "3")
(NOTE "2")
SIZE
(TYP.) (TYP.)
CLIPS
COLD FORMED CLIPS OF THK. 10 AND OVER.THE NEED TO CARRY OUT HEAT TREATMENT ONCOLD BUT CONSIDERATION SHALL BE GIVEN TO
2-PIPE CLIPS MAY BE FORMED EITHER HOT OR
CLIP BOLT WITH ENDS CUT SQUARE.SUITABLE BORE TO BE A FREE FIT ON THE BE MANUFACTURED FROM STEEL TUBE OF
3-DISTANCE PIECES FOR USE IN PIPE CLIPS SHALL
4-TYPE "B" SHALL ALSO BE USED FOR BAREPIPES ABOVE 100°C.
5-FOR ASSEMBLY DETAIL SEE SHEET No. 23.
HANGER SUPPORT
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
HR1
1-FOR GENERAL NOTES SEE SHEET No. 4.
2351
FOR HORIZONTAL PIPES
ROD : ASTM-A36 : ASTM-A283 Gr. C
5-MATERIAL SHALL BE AS FOLLOWS:
: ASTM-A668
A
RODFDIA. B1 C D1 E G1 H1 K
10
12
16
20
24
30
36
42 30
26
21
17
14
12
9
7
80
70
50
45
38
32
100
75
40
30
25
46
40
34
28
24
20
16
14
45
38
28
25
18
16
180
146
124
102
73
64
200
165
120
115
85
75
100
80
55
50
95
90
85
75
70
60
40
46
39
33
26
22
18
14
12
L DIA.BOLT
M10x70
M12x80
M16x110
M20x130
M24x150
M30x170
M36x200
M42x220
SIZE
FLAT SIZENxT1 LENGTH
DEVEL.
120x20
100x16
100x12
75x12
75x10
50x6 200
240
250
320
340
440
510
2-MINIMUM LENGTH OF THREAD ENGAGEMENT EQUALSDIAMETER OF ROD.
3-THE PIPE CLIPS SHALL REMAIN EXPOSED ANDSHALL NOT BE COVERED.
4-TACK WELD OF ROD TO EYE NUT SHALL BE DONEAFTER PIPE ELEVATION ADJUSTMENT IN OPERATION.
: ASTM-A307 : ASTM-A563
: ASTM-A283 Gr. C : ASTM-A500
DIMENSIONS TABLEL1
S MIN. MAX.
1500
26
30
38
46
54
66
78
96 280
230
200
160
140
110
90
80
ØA
L1
S S
ROD DETAIL
K
H1
L T1 N
EXISTING STRUCTURE
r=1.5T MIN.
LOCK NUT
FLAT
HOLE DIA.ØM
E
D1
ØC
ØA
F
G1
HANGER LUG DETAILEYE NUT DETAIL
MIN.
ØB1
HOLE
120
FLATEYE NUTBOLTNUTCLIPDISTANCE PIECE
NUT
ROD
EYE NUT
HANGER LUG
EYE NUT
CLIP
TACK WELD(TYP.)
EXISTING STRUCTURE
X
ASSEMBLYTYP. FOR TYPE A & B
BOLT
(NOTE "3")
NOTE "2"
NOTE "4"
MAX. LOAD
H
X
10
10
10
8
8
8
6
6
H
MIN. MAX.NPS DN
PIPE SIZE
1520
25405080100150
1/2"3/4"
1"1 /2"2"3"4"6"
270
275310315360375400
1600
1700
1
8"10"
200250
510540
12" 300 665
14" 350 760
2000
1800
80040016"
20" 500 90586545018"
109060024"
1/2"(DN15) ~ 24"(DN600)
NOTE "6"
6-FOR CLIP FABRICATION DETAILS SEE SHEETNo. 24.
DIA.ROD
10
12
16
20
24
30
36
42
(kg)LOADMAX.
5900
13501800
2250270036004500
450
900
280
IPS-D-PI-130
3"(DN80)~24"(DN600)
1/2"(DN15)~24"(DN600)
NOTES
22
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
G3
1-FOR GENERAL NOTES SEE SHEET No. 4.
INSULATIONMETALE COVER SHEET
OVER LAPPING OF THE METALCOVER SHEET
1/2"(DN15)~2"(DN50)
SHEETMETALE COVER
PAD
OVER LAPING OF THE METALCOVER SHEETTO BE SEALED
TO BE SEALED
2
GUIDE(TYP.)
INSULATION
1/2"~2"PIPESIZE
MARK
GUIDE L-50x5 L-60x6
(DN15~DN50) (DN80~DN150)3"~6" 16"~24"8"~14"
L-100x10 L-120x12
X
X(TYP.)
X
GUIDE(TYP.)
X
(DN200~DN350) (DN400~DN600)
2 TYP.
TYP.
2
GUIDE DETAIL
GUIDE SUPPORT FORHORIZONTAL COLD INSULATED PIPES
51
2-ANGLE MATERIAL : ASTM-A36.
(TYP.)
L
L
L
60 80 100
GUIDE SUPPORT
IPS-D-PI-130
1/2"(DN15)~6"(DN150)
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
8"(DN200)~24"(DN600)
FOR HORIZONTAL HOT INSULATED PIPES
G2
=
X
2-ANGLE MATERIAL : ASTM-A36 Gr. C.
1-FOR GENERAL NOTES SEE SHEET No. 4.
2151
(TYP.)
FREE TO SLIDENOTE "3"
= = =
SECTION
==
LL
= =
FREE TO SLIDENOTE "3"
(TYP.)X
PIPESIZE
SECTION
X
(DN150)~(DN450)6"~18"
L30x3
3 5 7
L50x5 L70x7
1/2"~4"(DN15~DN100)
20"(DN500) (DN600)
24"
SECTION
L 100
DETERMINED BY STRESS ANALYST.3-THE GAP BETWEEN SHOE & GUIDE SHALL BE
MAX.
LOAD (kg)
60
600 1500 2500LATERAL
GUIDE SUPPORT
IPS-D-PI-130
1/2"(DN15)~14"(DN350)
1/2"(DN15)~24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
16"(DN400)~24"(DN600)
G1
H
X
NOTE "3"
1-FOR GENERAL NOTES SEE SHEET No. 4.
2051
FREE TO SLIDE
FOR HORIZONTAL BARE PIPES
X
(TYP.)
X(TYP.)
FREE TO SLIDENOTE "3"
(TYP.)
X
PIPESIZE
H
SECTION
X
12"
(DN300)
10"
(DN250)
8"
(DN200)(DN150)
6"
L30x3
2"~4"
(DN350)
14"
3 5 7 8 4~5 4~6
L50x5 L70x7 L80x8 IPE 80 IPE 100
20015010050 350250
1/2"~11/2"
(DN15~DN40)
16"
(DN400)
18"
(DN450)
20"
(DN500)
LOAD (Kg)
MAX.200 400 600 800
(DN50~DN100) (DN600)
24"
1000
H
2-MATERIAL FOR SECTIONS SHALL BE ASTM-A36. SECTIONSECTION
MAX. LATERAL LOADMAX. LATERAL LOAD
3-THE GAP BETWEEN PIPE & GUIDE SHALL BEDETERMINED BY STRESS ANALYST.
LATERAL
1-FOR GENERAL NOTES SEE SHEET No. 4.
NOTES
AS PIPE MATERIAL, IT ALSO CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
2-MATERIAL OF REINFORCING PAD SHALL BE SAME
FROM STEEL STRUCTURE FIELD SUPPORT FOR VERTICAL PIPES
IPS-D-PI-130
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
FS5
1951
2"(DN 50)~24"(DN600)
1
X
X
1
300 550
250 400
350200
3.91
5.49
7.11
6.35
3390
2750
2280
860
430
130
TLOAD (Kg)MAX.
60024"
50020"
45018"
40016"
35014"
30012"
25010"
2008"
1506"
PIPE SIZE
100
80
50
DN2"
3"
4"
NPS A B
T
CLOSE END USING
BHOLE DIA. 10 50
10PIPE
DETAILS FOR PART 2(REINFORCING PAD)
DETAILS FOR PART 1
t
0 R
Ø 6 HOLE
r
r=25
L
NOTE "2"NOTE "3"
THK.6
a) PIPE : API 5L-Gr. B.4-MATERIAL SHALL BE AS FOLLOWES:
b) PLATE : ASTM-A283 Gr. C.
DNNPS
400
300
250
150
80
502"
3"
6"
10"
12"
16"
PART 2
(TYP.)
EXIST. STRUCTURE
LOADMAX.
LOADMAX.
LOADMAX.
(TYP.)22
(Lxt) R
305
254
228
203
178
162
136
110
84
57
45
30 105
120
115
120
115
105
85
95
95
85
100
110
350x5
350x6
350x8
500x10
600
450
350
350
300
250
250
230
180
120
100
60
0DEVELOP.LENGTH
X
B BB
A
2
PART 1
MAX.MAX.
OR ALLOY AND STAINLESS STEEL PIPES.3-REINFORCING PAD SHALL BE USED FOR CS-PWHT
NOTE "2 & 3"NOTE "2 & 3"
DETAILS FOR PART
OR +150 FROM PAVINGEXIST. STRUCTURE
2-FOR U-BOLT SEE SHEET No. 47.
1-FOR GENERAL NOTES SEE SHEET No. 4.
NOTES
1/2"(DN 15)~1 1/2"(DN40)
5118
FS4
210
DESCRIPTION
DRAWING No.
IRANIAN PETROLEUM STANDARDS REV. DATE
DATE SHEET REV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IPS-D-PI-130
FIELD SUPPORT FOR PIPES
MAX. 150
0
6
L-50x5
P
30 20
25 25
100
1001
TYPE "A"
MAX. 140
0
X
1
HOLE DIA. 7
U-BOLT
X
X
ASSEMIBLY FOR HORIZONTAL PIPES
X
EXIST. STRUCTUREOR +150 FROM PAVING
X X
==
C OF PIPEL
2
U-BOLTNOTE "2"
PIPES ASSEMIBLY FOR VERTICAL
TYPE "B"
100
100
25
25
6
HOLE DIA. 7
L-50x5
2DETAILS FOR PARTNOTE "2 & 4"NOTE "2 & 4"
SECTION C-C
TYPE "C"(ASSEMIBLY FOR VERTICAL PIPES ADJACENT TO STEEL STRUCTURE)
50
150X
EXIST. STRUCTURE
FLAT 50x6 NOTE "3"
3-BASE MATERIAL OF FLAT SHALL BE SAME AS PIPE MATERIAL.
CC
MAX. 120
0
4-MATERIAL SHALL BE AS FOLLOWS: a) ANGLE : ASTM-A36 b) PLATE : ASTM-A283 Gr. C
NOTE"2"
MAX. 120
0
MAX. 210
K
K
100
1/2" 30 65
3/4" 36 68
1" 44 72
11/2" 58 7940
25
20
15
NPS P KPIPE SIZE
DN
X
20
30
K
P
FIELD SUPPORT FOR VERTICAL ELBOW
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
FS3
DIMENSION TABLE
1-FOR GENERAL NOTES SEE SHEET No. 4.
NPS
4"
3"
2"
DN
MAX. H
EIGHT
A
DETAILS FOR PART 1
50
80
100
1751
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
MAX. A
5000
2500
400 830
1160
100
200
200
MAX.MIN.HEIGHT
X
X
EXIST. STRUCTUREOR +150 FROM PAVING
SUPPORT ASSEMBLY
1
2
MATERIAL OF ELBOW . WELDING OF NECK TO ELBOW SHALL BE DONE IN ACCORDANCE WITH
2-MATERIAL OF NECK SHALL BE SAME AS BASE
2"(DN 50)~24"(DN600)
LOAD (Kg)
X
MIN.
dt
50
L1 "A"
d
VIEW "A"
d
DNNPS
150910700
L1 t
3"
10"
6"
2"
80
250
150
50
210
755
520
155
4" 100
2008"
145
190
320
350
500
610
630
780
PIPING WELDING PROCEDURE.
SEE NOTE "2"
1160
(NOTE "3")
3-FOR DETAILS OF PART 2 SEE SHEET No. 13.
ACC. TO
PIPING P
ROJECT SP
ECIFICATION
EMBEDED PLATE
SUPPORT WILL INCREASE ITS LOAD-CARRYINGTABLE, SO A REDUCTION IN THE HEIGHT OFON THE MAXIMUM HEIGHT GIVEN IN THE
4-ALL MAXIMUM LOADS ARE CALCULATED BASED
CAPACITY.
(NOTE "4")
(BY CIVIL)
FIELD SUPPORT FOR HORIZONTAL PIPES
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
FS2
1-FOR GENERAL NOTES SEE SHEET No. 4.
16
1250
2900
4300
MAX.
60024"
50020"
45018"
40016"
35014"
30012"
25010"
2008"
1506"
PIPE SIZE
100
80
50
DN2"
3"
4"
NPS
OR +150 FROM PAVINGEXIST. STRUCTURE
AS PIPE MATERIAL , IT ALSO CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
3-MATERIAL OF REINFORCING PAD SHALL BE SAME
4-FOR FABRICATION DETAILS SEE SHEET No. 12.
2"(DN 50)~24"(DN600)(ASSEMBLY)
LOAD TABLE5
3
2X
MIN. 150
MAX. 100
0X
1
X
X
LOAD (Kg)
51
5
3
X
NOTE "2 & 3"
WELDING DETAIL
WILL INCREASE ITS LOAD-CARRYING CAPACITY.A REDUCTION IN THE HEIGHT OF SUPPORT ON THE MAXIMUM HEIGHT OF 1000 MM, SO
6-ALL MAXIMUM LOADS ARE CALCULATED BASED
(NOTE "6")
SHEET No. 19.5-FOR FABRICATION DETAIL OF PART 1 SEE
EMBEDED PLATE(BY CIVIL)
OR ALLOY AND STAINLESS STEEL PIPES.2-REINFORCING PAD SHALL BE USED FOR CS-PWHT
FIELD SUPPORT FOR VERTICAL PIPES
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
FS1
LOAD TABLE
1-FOR GENERAL NOTES SEE SHEET No. 4.
NPS
4"
3"
2"
DN50
80
100
1551
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
MAX. A
700
600
200 800
1400
2000
100
150
MAX.MIN.HEIGHT
OR +150 FROM PAVINGEXIST. STRUCTURE
X
50
A
MAX. H
EIGHT
X
3
1
AS PIPE MATERIAL, IT ALSO CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
3-MATERIAL OF REINFORCING PAD SHALL BE SAME
4-FOR FABRICATION DETAIL OF PART 3 SEE
2"(DN 50)~24"(DN600)NEAR ELBOW (ASSEMBLY)
X LOAD (Kg)
SHEET No. 10.
PART 3 .6-WELD SHALL BE GROUND IN CONTACT WITH
EMBEDED PLATE
MIN.
(NOTE "7")
1000500
ON THE MAXIMUM HEIGHT GIVEN IN THE7-ALL MAXIMUM LOADS ARE CALCULATED BASED
TABLE, SO A REDUCTION IN THE HEIGHT OFSUPPORT WILL INCREASE ITS LOAD-CARRYINGCAPACITY.
NOTE "2 & 3"
SHEET No. 19.5-FOR FABRICATION DETAIL OF PART 1 SEE
NOTE "6"
(BY CIVIL)
OR ALLOY AND STAINLESS STEEL PIPES.2-REINFORCING PAD SHALL BE USED FOR CS-PWHT
DUMMY SUPPORT FOR ELBOWS
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
DS1
DIMENSION TABLE
1-FOR GENERAL NOTES SEE SHEET No. 4.
NPS
4"
3"
2"
DN
50
50
80
100
1451
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
dt2t1
t12
1
MATERIAL OF ELBOW. WELDING OF NECK TO
a) PIPE : API 5L-Gr.B 3-MATERIAL SHALL BE AS FOLLOWS:
ELBOW SHALL BE DONE IN ACCORDANCE WITH
2-MATERIAL OF NECK SHALL BE SAME AS BASE
1/2"(DN 15)~24"(DN600)
L1
L
t2 EXIST.
NECK
SUPPORT
TYPE "B"
50
t1
TYPE "C"
21
(VERTICAL OR HORIZONTAL
L
t2 EXIST.
NECK
SUPPORT
50
L
21
EXIST.SUPPORT
NECK
t1
t2
200 200
ELBOW WITH COAXIAL NECK)(VERTICAL ELBOW WITH COMMON B.O.P.)(VERTICAL ELBOW WITH COMMON B.O.P.)
TYPE "A"
200
4011/2"
25
20
151/2"
3/4"
1"
DNNPS
1"
3/4"
1/2" 15
20
25
11/2" 40
1270
1065
965
865
760
670
570
465
365
260
210
155 155
145
190
210
320
350
500
520
610
630
755
780600
615
500
430
425
265
160
155 2"
3"
6"
10"
12"
16" 400
300
250
150
80
50 3.9
5.5
7.1
6.4
3.7
3.9
4.5
5.1
120 120 120
"A"TYPETYPE
"B"TYPE"C"
ACCORDING TO P
ROJECT PIPING S
PEC
IFICATION
L1
d
t1
(SEE NOTES "2" & "4")
DETAILS FOR PART 1
MAX. 2600
t2
d
50Ø 10 HOLE
10
t2
PLATE 6 THK.PIPE
DETAILS FOR PART 2(SEE NOTES "3" & "4")
NECK
PIPING WELDING PROCEDURE.
b) PLATE : ASTM-A283 Gr.C
MAX.L
1500
2000
2500
4-DIMENSION OF BEVEL END SHALL BE AS PERANSI B16.25.
BASE ANCHOR FOR VERTICAL ELBOW
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BA3
TYPE "A"
1351
(ON CONCRETE)
2"(DN 50)~24"(DN600)
HOLE DIA.
ANCHOR BOLT
HS
SECTION
MIN.
X
6
X
A
MAX. H
EIGHT
X
ANCHOR BOLT
MAX. H
EIGHT
A
X
6
X
MIN.
X
2
1
2
1
(ON STEEL STRUCTURE)
TYPE "B"
DETAILS FOR PART 2
PIPING WELDING PROCEDURE.
2-MATERIAL OF NECK SHALL BE SAME AS BASE
ELBOW SHALL BE DONE IN ACCORDANCE WITH MATERIAL OF ELBOW . WELDING OF NECK TO
1-FOR GENERAL NOTES SEE SHEET No. 4.
E
24
60
40
20880
1300
1000
6
12
10
25
50
30
L-50X5
L-100x10
L-150x15
L-60x6
HS
900 910 150
CSECTIONHEIGHT MIN.MAX.
200
100
1160
830600
2950
5000
AMAX.
60024"
50020"
45018"
40016"
35014"
30012"
25010"
2008"
1506"
PIPE SIZE
100
80
50
DN2"
3"
4"
NPS
DIMENSION TABLE
LOAD (Kg)VERT.HORIZ.
LOAD (Kg)
MAX.
800
150
40
80
B
170
320
280
140
(SHALL BE SUPPLIED BY CIVIL)
ANCHORBOLT
M16x140
M20x165
NOTE "3"
HOLEDIA.
22
18
3-DRILLING OF PLATE SHALL BE DONE ONLY FOR
+150 FROM PAVING EXIST. STRUCTURE
(NOTE "3")
==
NOTE "4"
(NOTE "5")
4-FOR DETAILS OF PART 1 SEE SHEET No.17.
5-MATERIAL SHALL BE AS FOLLOWS:a)CHANNEL :ASTM-A36b)PLATE :ASTM-A283 GR.C
ANCHOR TYPE "A".
EMBEDED PLATE
==
B
B
SUPPORT WILL INCREASE ITS LOAD-CARRYING TABLE, SO A REDUCTION IN THE HEIGHT OF ON THE MAXIMUM HEIGHT GIVEN IN THE
6-ALL MAXIMUM LOADS ARE CALCULATED BASED
(NOTE "6")
CAPACITY.
NOTE "4"
(BY CIVIL)
C CE
X X
X
FABRICATION DETAILS
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BA2
1-FOR GENERAL NOTES SEE SHEET No. 4.
12
[-50
[-100
[-140
ASECTION
350
250
150
60024"
50020"
45018"
40016"
35014"
30012"
25010"
2008"
1506"
PIPE SIZE
100
80
50DN
2"
3"
4"
NPS
2"(DN 50)~24"(DN600)
TABLE"2" & "3"
A
DETAILS FOR PART 2
TABLE"4" & "5"
NPS
4"
3"
2"
DN50
80
100
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
SECTION
[-200
[-160
[-100
10
12
16
18
20
140
200
240
160
170
180
SECB
DETAILS FOR PART 4
==
= =B
SECTION
C
BASE ANCHOR FOR HORIZONTAL PIPES
E
650
S
SECTION
DETAILS FOR PART 3
460
M20x165
M16x140
BOLT
51
F
HOLE DIA.
"A"
B==
C=
=
E
SECTION
DETAILS FOR PART 5
F
35
30
ANCHORHOLEDIA.
22
18
VIEW "A"
665
0
(NOTE "2")
SECTION
: ASTM-A36.
2-MATERIAL SHALL BE AS FOLLOWS:
b) CHANNEL a) PLATE : ASTM-A283 Gr. C.
PART 4 PART 5
150
130
100XXX
F
BASE ANCHOR FOR HORIZONTAL PIPES
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BA2
LOAD TABLE
1-FOR GENERAL NOTES SEE SHEET No. 4.
NPS
4"
3"
2"
DN
MAX. 100
0
MIN. 150
TYPE "B"
50
80
100
11
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
MAX.
4500
2800
1150
X
X
+150 FROM PAVING
TYPE "A"
EXIST. STRUCTURE
2
(ON STEEL STRUCTURE)
2-FOR FABRICATION DETAILS SEE SHEET No. 12.
2"(DN 50)~24"(DN600)(ASSEMBLY)
(ON CONCRETE)
3
4 5
3
2X
MIN. 150
MAX. 100
0
X
X X
LOAD (Kg)
51
X
(SHALL BE SUPPLIED BY CIVIL)ANCHOR BOLT
X
VERT.LOAD (Kg)
HORIZ.MAX.
60
170
290
X
4-FOR WELDING DETAIL SEE SHEET No. 16.
1
X X
1
NOTE "4"
EMBEDED PLATE
(NOTE "5")
ON THE MAXIMUM HEIGHT OF 1000 MM, SO 5-ALL MAXIMUM LOADS ARE CALCULATED BASED
A REDUCTION IN THE HEIGHT OF SUPPORT WILL INCREASE ITS LOAD-CARRYING CAPACITY.
NOTE "6 & 7"
SHEET No. 19.3-FOR FABRICATION DETAIL OF PART 1 SEE
7-MATERIAL OF REINFORCING PAD SHALL BE SAMEAS PIPE MATERIAL, IT ALSO CAN BE MADE OF PIPE SEGMENT INSTEAD OF PLATE.
NOTE "6 & 7"
(BY CIVIL)
OR ALLOY AND STAINLESS STEEL PIPES.6-REINFORCING PAD SHALL BE USED FOR CS-PWHT
FABRICATION DETAILS
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BA1
1-FOR GENERAL NOTES SEE SHEET No. 4.
1051
2"(DN 50)~24"(DN600)
TABLE "2" & "3"
NPS
4"
3"
2"DN50
80
100
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
800
1400
2000
SECTION H
[-200
[-140
[-50
10
14
18
100
180
130
180
SEDCMAX.
DETAILS FOR PART 2
==
==
SECTION
D
BASE ANCHOR FOR VERTICAL PIPES
E
DETAILS FOR PART 3
F
35
25
HOLEDIA.
ANCHORBOLT
M16x140
M20x165
18
22
S S
E
D
= =
==
SECTION
C
"A"
HOLE DIA.
F
NOTE "2"NOTE "2"
VIEW "A"
C
: ASTM-A36.
2-MATERIAL SHALL BE AS FOLLOWS:
b) CHANNEL a) PLATE : ASTM-A283 Gr. C.
H H
PART 2 PART 3
120
80
F
(SHALL BE SUPPLIED BY CIVIL)ANCHOR BOLT
XX X
[-100 800 160 140100 16 30
150 240 20 12
BASE ANCHOR FOR VERTICAL PIPES
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BA1
LOAD TABLE
1-FOR GENERAL NOTES SEE SHEET No. 4.
NPS
4"
3"
2"
DN
MAX. H
EIGHT
A
TYPE "B"
50
80
100
951
PIPE SIZE
6" 150
8" 200
10" 250
12" 300
14" 350
16" 400
18" 450
20" 500
24" 600
MAX. A
2900
1700
700 60
140
170
100
150
MIN.
50
X
+150 FROM PAVING
TYPE "A"
EXIST. STRUCTURE
X
A
MAX. H
EIGHT2 3
(ON STEEL STRUCTURE)
2-FOR FABRICATION DETAILS SEE SHEET No. 10.
2"(DN 50)~24"(DN600)NEAR ELBOW (ASSEMBLY)
(ON CONCRETE)
LOAD (Kg)
X
ANCHOR BOLT
VERT.LOAD (Kg)HORIZ.MAX.
MAX.HEIGHT
2000
1400
800
X
(SHALL BE SUPPLIED BY CIVIL)
X
X 1
50
1X
X
X
EMBEDED PLATE
1501400 1000
MIN.
MIN.
(NOTE "4")
SUPPORT WILL INCREASE ITS LOAD-CARRYING TABLE, SO A REDUCTION IN THE HEIGHT OF ON THE MAXIMUM HEIGHT GIVEN IN THE
4-ALL MAXIMUM LOADS ARE CALCULATED BASEDNOTE "5 & 6"
3-FOR FABRICATION DETAIL OF PART 1 SEESHEET No. 19.
CAPACITY.
OR ALLOY AND STAINLESS STEEL PIPES.5-REINFORCING PAD SHALL BE USED FOR CS-PWHT
(BY CIVIL)
NOTE "5 & 6"
6-MATERIAL OF REINFORCING PAD SHALL BE SAME
PIPE SEGMENT INSTEAD OF PLATE.AS PIPE MATERIAL, IT ALSO CAN BE MADE OF
NOTE "7" NOTE "7"
7-WELD SHALL BE GROUND IN CONTACT WITHPART 2 .
END WELDED BRACED CANTILEVER
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
1-FOR GENERAL NOTES SEE SHEET No. 4.
8
2-MATERIALS SHALL BE AS FOLLOWS:a) SECTION : ASTM A-36b) PLATE : ASTM A-283 GR.C
B3
SECTION A-A
L
EXIST. STRUCTURE
TYPE SECTION
A
B
C
D
AMAX. LOAD (Kg)
IPE-80
IPE-100
IPE-120
IPE-160
200 2940
250 4300
5840
10500
REINF.PLATETHK.
6
8
8
10
MAX. LOAD X
(FOR HORIZONTAL PIPES)
LOAD TABLE FOR TYPE I & II
L=500 L=750 L=1000 L=1500
45°
TYPE I
A
45°
MAX. LOADL
TYPE II(FOR VERTICAL PIPES)
E
F
HEA-100
HEA-140
250
300
250
300
L=2000
4830
3290
1970
3600
2090
1110
6910
40208370
9780 8900
7070
11700 10270
1650
2270
4420
8550
10
10
X
X
X
200
SECTION
REINFORCING PLATE
EXIST. STRUCTURE X
X
50X
X
50
50
A
A
10
50x50x10
X
ANGLE
IPS-D-PI-130
-
-
-
-
-
BRACKET
(TYP.)
K K
3-ANGLE SIZE & DIMENSION "K" TO BE DEFINED BY PIPING SUPPORT DESIGNER.
51
X
MAX. LOAD(TYP.)
(TYP.)
(TYP.)
LONGITUDINALLY WELDED PLAIN CANTILEVER
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BRACKET
1-FOR GENERAL NOTES SEE SHEET No. 4.
E
L
[ 180250
100
1501880
2800
3470
520
330
190
100
780
1210
7290
5860
4590 1850
3060
1360
1100
720
2170
2830
3580
570
310
30
70
130
210
1610
1300
850
2640
3410
4310
690
390
40
90
160
260
1960
1580
1040
SECTION
X
X
L1
MAX. LOAD
TYPE "A" TYPE "B"
L 80x8
L 40x4
L 50x5
L 60x6
L 70x7
[ 160
[ 120
[ 200
3350
4310
5420
860
520
60
120
220
350
2500
2020
1340
170
100
40
-
260
460
2410 1860
260
180
-
20
50
100
500
840
1040
2370
1420 930
1570
610
370
210
40
-
-
-
70
110
1230
170
110
-
-
30
60
320
570
850
1930
1510
1160
7
B2
20 20 L
MAX. LOAD
L1
X
[ 100
[ 80
[ 140200
FLAT 50x6SEE DETAIL "1"
(TYP.)
X2-MATERIAL SHALL BE AS FOLLOWS:
MAX. LOAD (Kg) L=1000 L=1250L=800L=600L=300 L=400 L=500L=200
a) SECTION : ASTM-A36b) FLAT : ASTM-A283 Gr. C
DETAIL "1"
E6
50
L1
80
70
60
50
40
45
50
55
60
65
75
70
A A
AMIN.
160
180
140
120
100
80
40
50
60
SECTION
EXIST. STRUCTUREEXIST. STRUCTURE
SECTION
TYPE
A
B
LOAD TABLE
51
XX
END WELDED PLAIN CANTILEVER
IPS-D-PI-130
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
BRACKET
1-FOR GENERAL NOTES SEE SHEET No. 4.
2-MATERIAL SHALL BE AS FOLLOWS:
MAX. LOAD (Kg) E
L
[ 140
50
64
55
70
60
50
40
8046
55
75
60
1770
1960
2690
520
320
180
90
780
1080
5440
4040
3080 1020
1810
890
650
590
1230
1610
2170
430
310
20
60
130
200
1070
780
700
1540
2020
2720
540
390
40
90
160
260
1340
980
880
SECTION
L1
XMAX. LOAD
EXIST. STRUCTURE
MAX. LOAD
TYPE "A" TYPE "B"
IPE 80
L 80X8
L 40X4
L 50X5
L 60X6
L 70X7
[ 120
IPE 120
[ 100
[ 160
IPE 100
2050
2690
3620
720
520
60
120
210
340
1790
1300
1180
170
100
40
-
260
350
1340 1010
200
180
-
20
50
100
410
490
670
1360
770 370
870
320
200
170
40
-
-
-
70
80
610
120
110
-
-
30
60
260
320
500
1080
800
570
L=1000 L=1250L=800L=600L=300 L=400 L=500L=200
a) SECTION :ASTM-A36b) FLAT :ASTM-A283 Gr. C
6
B1
FLAT 50x6SEE DETAIL "1"
X
L1L
(TYP.)
DETAIL "1"
E6
50
150
100
200
L1TYPE
A
B
SECTION SECTION
SECTION
X
L L1
MAX. LOAD
TYPE "C"
C
L=250SECTIONTYPE
C
MAX. LOAD (Kg) S
L=500 L=750 L=1000
L-40L
L-80L
L-120L
L-160L
6
8
8
10 7420
4470
2000
500
3710
2240
1000
190
2480
1490
630
85
1860
1000
350
-
L1
200
PLAIN CANTILEVER FORSPRING SUPPORT
S A
B
SECTION A-A
A
A
X 160
120
80
40
BC
30
30
40
50 180
150
120
100
A
LOAD TABLE FOR TYPE "C"
LOAD TABLE FOR TYPE "A" & "B"
X
51
X
ANCHOR FOR HORIZONTAL
IPS-D-PI-130
3"(DN80)~6"(DN150)
3"(DN80) ~ 24"(DN600)
NOTES
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
REV. SHEET DATE
DATE REV.
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
8"(DN200)~18"(DN450)
A1
X
X
X
X
20"(DN500)~24"(DN600)
EXISTING
1-FOR GENERAL NOTES SEE SHEET No. 4.
3-FOR SHOES DETAILS SEE SHEET No.
PIPE SIZE MAX. LATERAL
551
STRUCTURE
X
NPS DN
3"~6"
8"
10"
12"~14"
16"
18"
80~150
200
250
400
450
20" 500
60024"
300~350
FORCE(Kg)
MAX. BENDINGMOMENT(Kg-m)
MOMENTMAX. TORSIONAL
(Kg-m)(Kg)FORCE
MAX. AXIAL
350
900
1000
1000
2260
120
200
60
110
3000
400
300
350
140
210
280
310
350
420
HOT INSULATED PIPES
2-LOADS AND MOMENTS SHOWN IN THE TABLE, ARE VALID FOR MINIMUM 300mm.SHOE'S LENGTH. FOR LESSER LENGTH IT SHALL BE
300MIN.MIN.
300
300MIN.
SEE NOTE "2"
X
STRUCTUREEXISTING
SEE NOTE "3"SEE NOTE "3"
SEE NOTE "3"
X
EXISTINGSTRUCTURE
X
CALCULATED.
42 TO 45.
X
(TYP.)
DATE SHEET REV.
DATEREV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
IPS-D-PI-130
GENERAL NOTES
WHERE "t" IS THE PLATE OR SECTION THICKNESS.
XX
2-SYMBOL DENOTES "FIELD WELD".
1-ALL THICKNESS VALUES AND DIMENSIONS ARE IN mm.
t > 6 X=6 t < 6 X=t3-THE THICKNESS "X" (WELD LEG) SHALL BE AS FOLLOWS:
SYMBOL DENOTES "SHOP WELD".
10-THE STRENGTH OF MATERIALS USED IN THE CONSTRUCTION OFSUPPORTS MUST COMPLY WITH THE IPS-E-PI-240.
6-ALL THREADS SHALL COMPLY WITH THE REQUIREMENTS OF
7-DIMENSIONS OF NUTS & LOCK NUTS SHALL BE IN ACCORDANCEWITH ANSI B18.2.2.
8-FOR LOADS OTHER THAN THOSE LISTED IN THE TABLES, MORE CALCULATINOS SHALL BE PERFORMED IN ORDER TO SPECIFY THE SIZES OF STRUCTURAL SECTIONS.
9-IN CASE WHEN THE SUPPORT IS ATTACHED TO THE EXISTINGSTRUCTURE, THE EXISTING STRUCTURE SHOULD BE CHECKED FORTHE APPLIED LOADS.
4-UNLESS OTHERWISE SPECIFIED ON DRAWINGS, ALL PIECES DIRECTLYWELDED TO PIPING SHALL BE THE SAME MATERIAL AS OF PIPE.
5-WELDING OPERATIONS SHALL BE DONE IN ACCORDANCE WITH RELATEDWELDING PROJECT SPECIFICATIONS.
11-THE MATERIAL USED FOR FABRICATION OF SUPPORTS MUST BE AS PER NOTES ON EACH STANDARD SUPPORT DRAWING SHEET. EQUIVALENT MATERIALS MAY BE USED SUBJECT TO ENGINEER'SAPPROVAL.
12-IN CASE OF SUPPORTS RESTING ON OR ANCHORED TO THE PAVING,THE PAVING MUST BE CHECKED FOR THE APPLIED FORCES ANDMOMENTS.
13-IF IT IS NECESSARY THAT THE WELD BETWEEN A PIPE AND SADDLEMUST UNDERGO HEAT TREATMENT AND IF SUPPORT ERECTION STANDARDS LAY DOWN THAT THE SADDLE SHOULD BE WELDED TO THE REST OF THE SUPPORT AT THE PREASSEMBLY STAGE, THE LATTER MUST BE IGNORED AND THE SUPPORT MUST BEWELDED TO THE PLATE AFTER HEAT TREATMENT.
14-SUPPORTS RESTING ON OR ANCHORED TO THE PAVING OR TO PREFABRICATED BASE PLATES SHALL BE ADJUSTED USING A MAXIMUMGROUT THICKNESS OF 25mm.
ANSI B1.20.1.
51
15-ALL BOLTS SHALL BE OF MACHINE TYPE.
STANDARD PIPE SUPPORTS16-DIMENSIONS OF STRUCTURAL STEEL SECTIONS ARE BASED ON
DIN STANDARDS.
EVALUATED BY STRESS ENGINEER.17-THE EFFECT OF SUPPORT'S LOADS & MOMENTS ON PIPE, SHALL BE
4
18-PIPE SUPPORT SYMBOLS ARE AS FOLLOWS:TYPE OF SUPPORT PIPING ARRANGEMENT DWG. ISOMETRIC DWG.
ANCHOR
BRACKET
BASE ANCHOR
DUMMY SUPPORT
HANGER,HOLD DOWNS,FIELD SUPPORT,SHOES
FIELD SUPPORT FOR
LINE STOP
LINE STOP & GUIDE
ELEVATED SUPPORTOR T-POST
PICK-UP
VERTICAL ELBOW
FIELD SUPPORT FOR
NEAR ELBOWVERTICAL PIPE
GUIDE
FIELD SUPPORT FORVERTICAL PIPEFROM STRUCTURE
~ ~
~ ~
~
B
DS
~
FS
~
FS
FS
~ ~
~ ~
~ ~
~ ~
~ PU ~
~ ~
~
BA
~
~
~
~
~
~
~~
~
~
~
~
~
~
~
~~
~
~
~
~
~
~
~
~
~
~~~ ~
~
~
~
~
DATE SHEET REV.
DATEREV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
INDEXSTANDARD PIPE SUPPORTS
IPS-D-PI-130 3
FIGURE SUPPORTNO. TITLENO.
SHEET SHEETNO. TITLENO.
SUPPORTFIGURE SHEETNO. TITLENO.
SUPPORTFIGURE
31
32
33
41
42
43
34
35
36
44
45
46
37
38
39
47
48
49
5040 60
59
58
57
56
55
54
53
52
51HOLD DOWNSFOR PULSATING
COMPRESSOR PIPING
DROPDOWN SUPPORT
FIXED ENDED "T" POST
PU1
HOLD DOWNSFOR PULSATING
COMPRESSOR PIPING
FOR PULSATINGCOMPRESSOR PIPING
(ASSEMBLY)
(FABRICATION DETAILS)
FOR PULSATINGCOMPRESSOR PIPING
DROPDOWN SUPPORT
DROPDOWN SUPPORT
COMPRESSOR PIPINGFOR PULSATING
(FABRICATION DETAILS)
HORIZONTAL PIPES(ASSEMBLY)
PICK UP SUPPORT FOR
(HD)
(HD)
MISC.2
MISC.2
MISC.3(DDS)
(DDS)MISC.3
(DDS)MISC.3
MISC.4(P1)
MISC.5(C.PS)
CONCRETE PIPE
MISC.6(E.PS)
MISC.6(E.PS)
ELEVATED PIPE
ELEVATED PIPE
SUPPORT
SUPPORT
SUPPORT
51
(SECTION AND DETAILS)
PU1PICK UP SUPPORT FORHORIZONTAL PIPES
(FABRICATION DETAILS)
S1SLIDE SHOE H-100CS-WITHOUT PWHT
1/2"(DN15)~24"(DN600)
S2
S2
S1
SLIDE SHOE H-100
1/2"(DN15)~24"(DN600)
CS-PWHT,ALLOY &STAINLESS STEEL
SLIDE SHOE H-150
1/2"(DN15)~24"(DN600)
CS-PWHT,ALLOY &STAINLESS STEEL
SLIDE SHOE H-150CS-WITHOUT PWHT
1/2"(DN15)~24"(DN600)
VG1
VG2
U
S3
FOR VERTICAL PIPES
FOR VERTICAL PIPESVESSEL GUIDE SUPPORT
2"(DN50)~12"(DN300)
2"(DN50)~12"(DN300)
VESSEL GUIDE SUPPORT
1/2"(DN15)~24"(DN600)CARBON STEEL PIPES
1/2"(DN15)~24"(DN600)
U-BOLT FOR
COLD INSULATION SLIDE SHOE FOR
HORIZONTAL PIPES
2"(DN50)~18"(DN450)
VESSEL SUPPORTFOR VERTICAL PIPESVS1
FOR VERTICAL PIPES VESSEL SUPPORT
2"(DN50)~18"(DN450)VS1
DATE SHEET REV.
DATEREV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
INDEXSTANDARD PIPE SUPPORTS
IPS-D-PI-130 2
FIGURE SUPPORTNO. TITLENO.
SHEET SHEETNO. TITLENO.
SUPPORTFIGURE SHEETNO. TITLENO.
SUPPORTFIGURE
STANDARD PIPE SUPPORTS
INDEXSTANDARD PIPE SUPPORTS
1
2
3 STANDARD PIPE SUPPORTSINDEX
11
12
13
4
5
6
14
15
16
7
8
9
17
18
19
2010 30
29
28
27
26
25
24
23
22
21
B2
B3
BA1
B1BRACKET
END WELDED PLAINCANTILEVER
LONGITUDINALLY WELDEDBRACKET
PLAIN CANTILEVER
END WELDED BRACEDBRACKET
CANTILEVER
2"(DN50)~24"(DN600)
VERTICAL PIPES BASE ANCHOR FOR
NEAR ELBOW(ASSEMBLY)
(FABRICATION DETAILS)
BASE ANCHOR FORVERTICAL PIPES
2"(DN50)~24"(DN600)BA1
BA2
BA22"(DN50)~24"(DN600)
HORIZONTAL PIPES BASE ANCHOR FOR
(FABRICATION DETAILS)
(ASSEMBLY)
BASE ANCHOR FORHORIZONTAL PIPES
2"(DN50)~24"(DN600)
BASE ANCHOR FORVERTICAL ELBOWS
2"(DN50)~24"(DN600)BA3
DS11/2"(DN15)~24"(DN600)
FOR ELBOWSDUMMY SUPPORT
NEAR ELBOW(ASSEMBLY)
FIELD SUPPORT FORVERTICAL PIPES
2"(DN50)~24"(DN600)FS1
2"(DN50)~24"(DN600)
HORIZONTAL PIPES FIELD SUPOORT FOR
(ASSEMBLY)FS2
FS32"(DN50)~24"(DN600)VERTICAL ELBOWS FIELD SUPPORT FOR
1
FIELD SUPPORTFOR PIPES
1/2"(DN15)~1/2"(DN40)FS4
FS5 STEEL STRUCTURE2"(DN50)~24"(DN600)
VERTICAL PIPES FROMFIELD SUPPORT FOR
COVER SHEET
GUIDE SUPPORT FORHORIZONTAL BARE PIPES 1/2"(DN15)~24"(DN600)
G1
ANCHOR FOR HORIZ. HOT INSULATED PIPES 3"(DN80)~24"(DN600)
A1
GENERAL NOTES
51
G21/2"(DN15)~24"(DN600)HORIZ. INSULATED PIPES GUIDE SUPPORT FOR
INSULATION PIPES
GUIDE SUPPORT FORHORIZONTAL COLD
1/2"(DN15)~24"(DN600)G3
STANDARD PIPE SUPPORTS
MISC.1(ASW)
LS2
LS2
ADJUSTABLE SPRING
PULSATING PIPINGWEDGES FOR
HOT INSULATED PIPES LINE STOP FOR HORIZ.
1/2"(DN15)~24"(DN600)HOT INSULATED PIPESLINE STOP FOR HORIZ.
LS1
LS1
HR2
HR1
HR1
HORIZ. BARE PIPES 1/2"(DN15)~24"(DN600)
HORIZONTAL BARE PIPES LINE STOP FOR
LINE STOP FOR
HANGER SUPPORT
3"(DN80)~24"(DN600)
HORIZ. PIPES (CLIPSHANGER SUPPORT FOR
FABRICATION DETAILS)
PIPE TO PIPE
1/2"(DN15)~24"(DN600)
HANGER SUPPORT FORHORIZ.INSULATED PIPES
(FABRICATION DETAILS)
(FABRICATION DETAILS)
1
DATE SHEET REV.
DATEREV.
NO REVISION PERMITTED UNLESS APPROVED BY STANDARD ORGANIZATION
IRANIAN PETROLEUM STANDARDS
DRAWING No.
DESCRIPTION012
STANDARD PIPE SUPPORTS
IPS-D-PI-130
STANDARD PIPE SUPPORTS
51