H17958
Deployment Guide
VMware NSX-T Workload Domains on VxRail VMware Validated Design 5.1
VMware NSX-T 2.4.1
Abstract
This document provides guidance for the manual deployment of an NSX-T workload Domain in a VVD on VxRail environment.
October 2019
Revisions
2 VMware NSX-T Workload Domains on VxRail | H17958
Revisions Date Description
October 2019 Initial release
The information in this publication is provided “as is.” Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright © <pub date – rev date> Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. [10/8/2019] [Deployment Guide] [H17958]
Table of contents
3 VMware NSX-T Workload Domains on VxRail | H17958
Table of contents 1 About Deployment of VMware NSX-T Workload Domains .......................................................................................... 5
1.1 Intended audience .............................................................................................................................................. 5
1.2 Required software............................................................................................................................................... 5
1.3 Prerequisites ....................................................................................................................................................... 5
2 Preparing to Deploy a Workload Domain with NSX-T.................................................................................................. 6
2.1 Before you deploy a VI Workload Domain with NSX-T ...................................................................................... 6
2.2 Generate CA-signed certificates for the NSX-T Manager nodes ....................................................................... 8
3 Deploy and Configure the Shared Edge and Compute Cluster Components ............................................................ 11
3.1 Deploy the Compute vCenter Server instance for the Shared Edge and compute cluster .............................. 11
3.2 Replace the certificate of the Compute vCenter Server ................................................................................... 13
3.3 Set the SDDC deployment details on the Compute vCenter Server ................................................................ 14
3.4 Add and assign a license to the Compute vCenter Server .............................................................................. 15
3.5 Add the Compute vCenter Server to the virtual machine group for vCenter Server ........................................ 15
3.6 Exclude the Compute vCenter Server from the distributed firewall .................................................................. 15
3.7 Configure the Shared Edge and compute cluster ............................................................................................ 16
4 Perform the VxRail initialization to deploy the NSX-T Shared Edge and Compute Cluster ...................................... 18
4.1 Overview ........................................................................................................................................................... 18
4.2 Deploy the Shared Edge and Compute VxRail cluster .................................................................................... 20
4.3 Rename the VxRail assigned vCenter objects (optional) ................................................................................. 21
4.4 Modify vSphere HA on the Shared Edge and Compute Cluster ...................................................................... 22
4.5 Configure SSH advanced options on the ESXi hosts in the Shared Edge and Compute Cluster ................... 23
4.6 Configure syslog on the Shared Edge and Compute Cluster .......................................................................... 23
5 Deploy the NSX-T instance for the Shared Edge and Compute Cluster ................................................................... 25
5.1 Deploy the First NSX-T Manager Appliance .................................................................................................... 25
5.2 Import the CA-Signed Certificates for the NSX-T Manager Cluster ................................................................. 26
5.3 Replace the Certificate for the First NSX-T Manager Appliance ...................................................................... 27
5.4 Connect NSX-T Manager to the vCenter Server instances ............................................................................. 29
5.5 Deploy the Remaining Nodes of the NSX-T Manage Cluster .......................................................................... 30
5.6 Create an anti-affinity rule for the NSX-T Manager appliances ........................................................................ 31
5.7 Move the NSX-T Manager appliances to the NSX folder ................................................................................. 31
5.8 Replace the certificates for the remaining NSX-T Manager appliances........................................................... 32
5.9 Assign a virtual IP address and certificate to the NSX-T Manager cluster ...................................................... 33
5.10 Assign a Production License to NSX-T ............................................................................................................ 34
5.11 Create the transport zones for system and overlay traffic ................................................................................ 34
Table of contents
4 VMware NSX-T Workload Domains on VxRail | H17958
5.12 Create Uplink Profiles and the Network I/O Control Profile .............................................................................. 35
5.13 Create the NSX-T segments for system, uplink, and overlay traffic ................................................................. 37
5.14 Create a Transport Node Profile....................................................................................................................... 38
5.15 Configure the ESXi Host Transport Nodes ....................................................................................................... 38
6 Configure dynamic routing in the Shared Edge and Compute Cluster ...................................................................... 40
6.1 Create an NSX-T Edge Cluster Profile ............................................................................................................. 40
6.2 Deploy the NSX-T Edge appliances ................................................................................................................. 40
6.3 Join the NSX-T Edge Nodes to the management plane .................................................................................. 42
6.4 Create an anti-affinity rule for the NSX-T Edge nodes in the Shared Edge and Compute Cluster .................. 43
6.5 Add the NSX-T Edge Nodes to the transport zones......................................................................................... 44
6.6 Create an NSX-T Edge Cluster ........................................................................................................................ 45
6.7 Create and configure the Tier-0 gateway ......................................................................................................... 46
6.8 Create and configure the Tier-1 gateway ......................................................................................................... 47
6.9 Verify BGP peering and route redistribution ..................................................................................................... 49
7 Deploy a segment for a sample tenant workload ....................................................................................................... 50
8 Connect vRealize Log Insight to the NSX-T instance for the Shared Edge and Compute Cluster ........................... 51
8.1 Configure the NSX-T components to forward log events to vRealize Log Insight ........................................... 51
9 Back Up and Restore the NSX-T Instance for the Shared Edge and Compute Cluster ............................................ 52
9.1 Configure automatic backups of the NSX-T configuration ............................................................................... 52
9.2 Restore the NSX-T Manager Cluster................................................................................................................ 53
5 VMware NSX-T Workload Domains on VxRail | H17958
1 About Deployment of VMware NSX-T Workload Domains This document provides step-by-step instructions for extending a Standard SDDC with a VxRail virtual infrastructure workload domain that uses VMware NSX-T™ Data Center for software-defined networking.
1.1 Intended audience This document is intended for architects and administrators who want to deploy NSX-T in a virtual infrastructure workload domain for tenant workloads.
1.2 Required software This document is compliant and validated with certain product versions. See VMware Validated Design Release Notes for more information about the supported product versions.
• Software components for VMware Validated Design™ for Software-Defined Data Center 5.1 • NSX-T 2.4.1 • VxRail version 4.7.212 or later
1.3 Prerequisites Before you deploy VMware NSX-T workload domains, ensure the following:
• Your environment is a single region VVD deployment with a management workload domain, and optionally the initial virtual infrastructure workload domain.
• The deployment must align with the VMware Validated Design for Software-Defined Data Center on VxRail.
See the VVD 5.1 on Del EMC VxRail Appliance Version 4.7.2x Planning Guide on the Dell EMC support page.
6 VMware NSX-T Workload Domains on VxRail | H17958
2 Preparing to Deploy a Workload Domain with NSX-T Deployment of VMware NSX-T workload domains is based on VMware Validated Design™ for Software-Defined Data Center. Deploy the virtual network infrastructure on VMware NSX-T for a virtual infrastructure (VI) workload domain in a Shared Edge and compute cluster.
Deployment of VMware NSX-T Workload Domains adds an additional workload domain to VMware Validated Design.
2.1 Before you deploy a VI Workload Domain with NSX-T You must first deploy and configure the following components of the SDDC management cluster.
• VMware ESXi™ • VMware Platform Services Controller™ pair and Management vCenter Server® • VMware NSX® Data Center for vSphere® • VMware vRealize® Lifecycle Manager™ • vSphere® Update Manager™ • VMware vRealize® Operations Manager™ • VMware vRealize® Log Insight™ • VMware vRealize® Automation™ with embedded vRealize® Orchestrator™ • VMware vRealize® Business™ for Cloud
See the VVD 5.1 on Dell EMC VxRail Appliance Version 4.7.2x Planning Guide and the VVD 5.1 on Dell EMC VxRail for Region A Deployment Guide at https://www.dell.com/support.
If you follow the Standard VMware Validated Design guidance, a VI workload domain that uses NSX for vSphere as the solution for virtual networking is also deployed.
Before you deploy the NSX-T Shared Edge and compute cluster, verify that your environment satisfies the requirements listed in the following sections. You must allocate VLANs, host names and IP address in the SDDC network. The environment also must have a specific configuration of external services and virtual infrastructure.
2.1.1 IP addresses and host names Verify that the static IP addresses and FQDNs for all components are allocated on the DNS server and are available for deployment.
VLAN IDs and IP Subnets for the ESXi Hosts of the Workload Domain VLAN Function
VLAN ID Subnet Gateway
ESXi Management 1641 172.16.41.0/24 172.16.41.253 vSphere vMotion 1642 172.16.42.0/24 172.16.42.253 vSAN 1643 172.16.43.0/24 172.16.43.253 VxRail node discovery 3939 - -
NFS (optional) 1650 172.16.50.0/24 172.16.50.253 - - Host overlay 1644 172.16.44.0/24 172.16.44.253
Uplink01 1647 172.16.47.0/24 172.16.47.253 Uplink02 1648 172.16.48.0/24 172.16.48.253 Edge overlay 1649 172.16.49.0/24 172.16.49.253
7 VMware NSX-T Workload Domains on VxRail | H17958
FQDNs and IP Addresses for the ESXi Hosts of the Workload Domain ESXi Host FQDN Management IP Address NTP Server
sfo01w02esx01.sfo01.rainpole.local 172.16.41.101 ntp.sfo01.rainpole.local
sfo01w02esx02.sfo01.rainpole.local 172.16.41.102 ntp.sfo01.rainpole.local sfo01w02esx03.sfo01.rainpole.local 172.16.41.103 ntp.sfo01.rainpole.local sfo01w02esx04.sfo01.rainpole.local 172.16.41.104 ntp.sfo01.rainpole.local
FQDN and IP Address of the Compute vCenter Server vCenter Server FQDN IP Address
sfo01w02vc01.sfo01.rainpole.local 172.16.11.67
IP Addresses and Host Names for the NSX-T Components Role FQDN IP Address
NSX-T Manager instances sfo01wnsx01a.sfo01.rainpole.local 172.16.11.82 sfo01wnsx01b.sfo01.rainpole.local 172.16.11.83 sfo01wnsx01c.sfo01.rainpole.local 172.16.11.84 sfo01wnsx01.sfo01.rainpole.local (VIP) 172.16.11.81 Edge Services Gateway 01 sfo01wesg01.sfo01.rainpole.local 172.16.41.21 (Management) 172.16.49.21 (Overlay) 172.16.47.2 (Uplink 1) 172.16.48.2 (Uplink 2)
Edge Services Gateway 02 sfo01wesg02.sfo01.rainpole.local 172.16.41.22 (Management) 172.16.49.22 (Overlay) 172.16.47.3 (Uplink 1) 172.16.48.3 (Uplink 2)
Subnet mask - 255.255.255.0 DNS - 172.16.11.5 172.16.11.4 NTP Servers ntp.sfo01.rainpole.local 172.16.11.251 172.16.11.252
2.1.2 Deployment prerequisites Verify that your environment satisfies the following prerequisites for the deployment.
Deployment Prerequisites Prerequisite Value
Storage in the Management Cluster Virtual disk provisioning: Thin
Required storage per NSX-T Manager: • Initial storage: 200 GB • Initial storage aggregated for all NSX-T Managers: 600
GB Memory in the Management Cluster Required memory per NSX-T Manger node
• Required memory: 48 GB • Required memory aggregated for all NSX-T Manager
nodes: 144 GB
Network Connectivity Verify that routing is in place between the management IP subnets of the management cluster and the new workload domain.
8 VMware NSX-T Workload Domains on VxRail | H17958
Software Features • Verify that the Management vCenter Server is operational.
• Verify that the management cluster has vSphere DRS and vSphere HA enabled.
• Verify that you have the Postman REST client installed in your Web browser.
Installation Packages • Download the .iso image for the vCenter Server
Appliance. • Download the .ova file for the NSX-T Unified Appliance
and NSX-T Edge Node.
Active Directory Verify that you have a parent Active Directory with the SDDC user roles configured for the rainpole.local domain.
Certificate Authority and Custom Signed Certificates
• Configure the root Active Directory domain controller as a certificate authority for the environment.
• Create a Certificate Template called VMware for use with the CerGen certificate scripts.
• Download the CertGenVVD-version.zip file of the Certificate Generation Utility for VMware Validated Design 5.0.1 and generate signed certificates for the NSX-T Manager instances. See VMware Knowledge Base article 2146215.
Access to the data center Provide a Microsoft Windows virtual machine or physical
server to provide connection to the data center and store software downloads. The host must be connected to the external network and to the ESXi management network.
2.2 Generate CA-signed certificates for the NSX-T Manager nodes Using the Certificate Generation Utility for VMware Validated Design 5.1 (CertGenVVD), generate certificates for the NSX-T Manager instances and cluster virtual IP that are signed by the Microsoft certificate authority. Use these certificates for trusted communication between the NSX-T nodes and the other management components of the SDDC.
2.2.1 Procedure Log in to the Windows Server host that you allocated for certificate generation. Download the CertGenVVD-3.4.zip file from VMware Knowledge Base article 2146215. and
extract the ZIP file to C:\CertGenVVD-3.4. In the C:\CertGenVVD-3.4 folder, open the default.txt file in a text editor. Verify that the following properties are configured. ORG=Rainpole Inc. OU=Rainpole.local LOC=SFO ST=CA CC=US CN=VMware_VVD keysize=2048
In the C:\CertGenVVD-3.4\ConfigFiles folder, create four text files named sfo01wnsx01a.txt, sfo01wnsx01b.txt, sfo01wnsx01c.txt, and sfo01wnsx01.txt with the following content.
9 VMware NSX-T Workload Domains on VxRail | H17958
Certificate Configuration Text Files File Name File Content
sfo01wnsx01a.txt [CERT]
NAME=default ORG=default OU=default LOC=SFO ST=default CC=default CN=sfo01wnsx01a.sfo01.rainpole.local keysize=default [SAN] sfo01wnsx01asfo01wnsx01a.sfo01.rainpole.local
sfo01wnsx01b.txt [CERT] NAME=default ORG=default OU=default LOC=SFO ST=default CC=default CN=sfo01wnsx01b.sfo01.rainpole.local keysize=default [SAN] sfo01wnsx01bsfo01wnsx01b.sfo01.rainpole.local
sfo01wnsx01c.txt [CERT] NAME=default ORG=default OU=default LOC=SFO ST=default CC=default CN=sfo01wnsx01b.sfo01.rainpole.local keysize=default [SAN] sfo01wnsx01csfo01wnsx01c.sfo01.rainpole.local
sfo01wnsx01.txt
[CERT] NAME=default ORG=default OU=default LOC=SFO ST=default CC=default CN=sfo01wnsx01.sfo01.rainpole.local keysize=default [SAN] sfo01wnsx01sfo01wnsx01.sfo01.rainpole.local
To open a Windows PowerShell terminal as administrator, click Start, right-click Windows
> PowerShell, and select More > Run as Administrator. Configure the PowerShell execution policy with the permissions required for running
commands. Set-ExecutionPolicy Unrestricted
Verify if the CertGenVVD utility is configured for the generation. cd c:\CertGenVVD-3.4 .\CertGenVVD-3.4.ps1 -validate
Generate the MCSA-signed certificate. .\CertGenVVD-3.4.ps1 -MSCASigned -attrib 'CertificateTemplate:VMware'
10 VMware NSX-T Workload Domains on VxRail | H17958
Navigate to the C:\CertGenVVD-version folder and verify that the SignedByMSCACerts folder contains the certificates for the NSX-T Manager nodes and for the virtual IP of the cluster.
11 VMware NSX-T Workload Domains on VxRail | H17958
3 Deploy and Configure the Shared Edge and Compute Cluster Components Note: If a Workload Domain was deployed as part of a standard VVD deployment, a workload vCenter server exists within the management cluster.
The NSX-T VxRail Cluster can join that vCenter, and NSX-T manager can be configured to manage the network resources within that cluster. If the vCenter does not exist, or you require an isolated vCenter instance, proceed with the deployment, otherwise you can skip to Section 3.7.
3.1 Deploy the Compute vCenter Server instance for the Shared Edge and compute cluster To manage and configure the ESXi hosts in the additional workload domain with NSX-T and to provision tenant workloads from a centralized node, you must install and configure vCenter Server on the management cluster of Region A. Connect this vCenter Server instance to the Platform Services Controller pair that is available in the region to join the single vCenter Single Sign-on domain configured on the pair.
3.1.1 Procedure 1. Open a web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui,
using the vSphere Client with username [email protected] and password vsphere_admin_password.
2. Start the vCenter Server Appliance Deployment wizard. a. Browse to the .iso file of the vCenter Server Appliance. b. Run the dvd-drive:\vcsa-ui-installer\win32\Installer.exe application file.
3. To perform the first stage of the installation, complete the vCenter Server Appliance Deployment wizard. a. Click Install. b. On the Introduction page, click Next . c. On the End user license agreement page, select the I accept the terms of the license
agreement check box and click Next. d. On the Select deployment type page, under External Platform Services Controller, select the
vCenter Server (Requires External Platform Services Controller) radio button and click Next.
e. On the Appliance deployment target page, enter the following settings and click Next.
Appliance Deployment Target Settings Setting Value
ESXi host or vCenter Server name sfo01m01vc01.sfo01.rainpole.local
HTTPS Port 443 User name [email protected] Password vsphere_admin_password
f. In the Certificate Warning dialog box, click Yes to accept the host certificate. g. On the Select folder page, select sfo01-m01fd-mgmt and click Next. h. On the Select compute resource page, select the sfo01m01esx01.sfo01.rainpole.local
host and click Next. i. On the Setup appliance VM page, enter the following settings, and click Next.
12 VMware NSX-T Workload Domains on VxRail | H17958
Appliance Setup Settings Setting Value
VM name sfo01w02vc01
Root password compvc_root_password Confirm root password compvc_root_password
j. On the Select deployment size page, select Large vCenter Server and click Next. k. On the Select datastore page, select the sfo01-m01-vsan01 datastore, select the Enable
Thin Disk Mode check box, and click Next. l. On the Configure network settings page, enter the following settings and click Next.
Network Configuration Settings Setting Value
Network sfo01-m01-vds01-management IP version IPv4
IP assignment static FQDN sfo01w02vc01.sfo01.rainpole.local IP Address 172.16.11.67 Subnet mask or prefix length 255.255.255.0 Default gateway 172.16.11.253 DNS servers 172.16.11.5,172.16.11.4 HTTP 80 HTTPS 443
m. On the Ready to complete stage 1 page, review the configuration and click Finish. The deployment starts.
n. After the deployment finishes, to proceed to the second stage of the installation, click Continue.
4. Complete the Install - Stage 2: Set Up vCenter Server Appliance wizard to complete the second stage of the installation. a. On the Introduction page, click Next. b. On the Appliance configuration page, enter the following settings and click Next.
Appliance Configuration Settings Setting Value
Time synchronization mode Synchronize time with NTP servers
NTP servers (comma-separated list) ntp.sfo01.rainpole.local SSH access
Enabled
c. On the SSO configuration page, enter the following settings and click Next.
SSO Configuration Settings Setting Value
Platform Services Controller sfo01psc01.sfo01.rainpole.local
HTTPS port 443 SSO domain name vsphere.local SSO password sso_password
13 VMware NSX-T Workload Domains on VxRail | H17958
d. On the Ready to complete page, review the configuration and click Finish. e. In the Warning dialog box, click OK. f. On the Complete page, click Close.
5. Enable lockdown mode on sfo01m01esx01.sfo01.rainpole.local. a. In the vSphere Client, expand the sfo01-m01-mgmt01 cluster. b. Select sfo01m01esx01.sfo01.rainpole.local and click the Configure tab. c. Under the System section, select Security Profile and click Edit . d. In the sfo01m01esx01.sfo01.rainpole.local-Lockdown Mode dialog box, select Normal and
click OK.
3.2 Replace the certificate of the Compute vCenter Server To establish a trusted connection to the other SDDC management components, replace the default SSL certificate on the vCenter Server instance in the workload domain with a custom certificate that is signed by the certificate authority (CA) on the parent Active Directory (AD) server.
Use the following certificate files to replace the certificate on the Compute vCenter Server:
Certificate Files vCenter Server FQDN Files for Certificate Replacement
sfo01w02vc01.sfo01.rainpole.local • sfo01w02vc01.1.key
• sfo01w02vc01.1.cer • Root64.cer
3.2.1 Procedure 1. Log in to vCenter Server by using Secure Shell (SSH) client.
a. Open an SSH connection to the sfo01w02vc01.sfo01.rainpole.local virtual machine. b. Log in with username root and password vcenter_server_root_password.
2. To enable secure copy (scp) connections for the root user, switch from the appliance shell to the Bash shell.
shell chsh -s "/bin/bash" root
3. Copy the certificates that you generated by using the CertGenVVD utility to the vCenter Server Appliance.
a. Run the following command to create a new temporary folder. mkdir -p /root/certs b. Using a utility such as WinSCP, copy the certificate files sfo01w02vc01.1.cer,
sfo01w02vc01.key, and Root64.cer to the /root/certs folder. 4. Replace the CA-signed certificate on the vCenter Server instance.
a. Run the vSphere Certificate Manager utility on the vCenter Server instance. /usr/lib/vmware-vmca/bin/certificate-manager b. Select Option 1 (Replace Machine SSL certificate with Custom Certificate), enter
the default vCenter Single Sign-On user name [email protected] and vsphere_admin_password.
c. When prompted for the Infrastructure Server IP, enter the VIP address of the Platform Services Controller pair in Region A.
Infrastructure Server IP Setting Value
Infrastructure server IP 172.16.11.71
14 VMware NSX-T Workload Domains on VxRail | H17958
d. Select Option 2 (Import custom certificate(s) and key(s) to replace existing Machine SSL certificate).
e. When prompted, provide the full path to the custom certificate, the root certificate file, and the key file that you copied over earlier, and confirm the import with Yes (Y).
Path to Custom Certificate Setting Value
Custom certificate for Machine SSL /root/certs/sfo01w02vc01.1.cer
Custom key for Machine SSL /root/certs/sfo01w02vc01.key Signing certificate of the Machine SSL certificate /root/certs/Root64.cer
5. After the status is 100% Completed, wait several minutes until all vCenter Server services are restarted.
6. Restart the vami-lighttp service to update the certificate on the virtual appliance management interface (VAMI) and to remove the certificate files.
service vami-lighttp restart cd /root/certs/ rm sfo01w02vc01.1.cer sfo01w02vc01.key Root64.cer
3.3 Set the SDDC deployment details on the Compute vCenter Server
Update the identity of your SDDC deployment on the Compute vCenter Server in the workload domain. You can use this identity as a label in tools for automated SDDC deployment.
3.3.1 Procedure 1. In a Web browser, log in to vCenter Server by using the vSphere Client. 2. In the Hosts and Clusters inventory, select the sfo01m01vc01.sfo01.rainpole.local vCenter
Server object and click the Configure tab. 3. Under the Settings section, select Advanced Settings. 4. Locate the config.SDDC.Deployed.InstanceId setting and write down its value. 5. In the Hosts and Clusters inventory, select the sfo01w02vc01.sfo01.rainpole.local vCenter Server
object and click the Configure tab. 6. Under the Settings section, select Advanced Settings and click Edit. 7. In the Edit Advanced vCenter Server Settings dialog box, set the following value pairs one by
one, clicking Add after each entry, and click OK.
Advanced vCenter Server Settings Name Value
config.SDDC.Deployed.Type VVD
config.SDDC.Deployed.Flavor Standard
config.SDDC.Deployed.Version 5.1
config.SDDC.Deployed.WorkloadDomain SharedEdgeAndCompute
config.SDDC.Deployed.Method DIY
config.SDDC.Deployed.InstanceId Value obtained in Step 4
15 VMware NSX-T Workload Domains on VxRail | H17958
3.4 Add and assign a license to the Compute vCenter Server Assign a license key to the Compute vCenter Server for the workload domain to use its features in production. If the capacity of the licenses for vCenter Server and ESXi is insufficient to license the new instances, add new licenses to the inventory of the License Service.
3.4.1 Procedure 1. Open a Web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui,
using the vSphere Client with username [email protected] and password vsphere_admin_password.
2. From the menu, select Administration. 3. On the Administration page, select Licenses. 4. If the capacity of the available licenses is not sufficient to license the nodes of the workload
domain, add the licenses to the inventory of the License Service. 5. On the Licenses tab, click Add New Licenses. 6. On the Enter license keys page, enter the license keys for vCenter Server and ESXi on separate
lines, and click Next. 7. On the Edit license name page, enter a descriptive name for the license key, and click Next. 8. On the Ready to complete page, review your entries, and click Finish.
a. Assign the license to the Compute vCenter Server for the workload domain. b. Click the Assets tab and click vCenter Server systems. c. Select the sfo01w02vc01.sfo01.rainpole.local vCenter Server instance, and click the
Assign License icon. d. Select the license for the Compute vCenter Server and click OK.
3.5 Add the Compute vCenter Server to the virtual machine group for vCenter Server The Compute vCenter Server for the workload domain must be a member of the virtual machine group so that it is powered on, in a group with the other vCenter Server instances, after the Platform Services Controller pair. In this way, the services of the Platform Services Controller nodes are available to the Compute vCenter Server after a vSphere HA migration occurs.
3.5.1 Procedure 1. Open a Web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui,
using the vSphere Client with username [email protected] and password vsphere_admin_password.
2. In the Hosts and clusters inventory, expand the sfo01m01vc01.sfo01.rainpole.local tree and expand the sfo01-m01dc data center.
3. Select the sfo01-m01-mgmt01 cluster and click the Configure tab. 4. On the Configure page, click VM/Host Groups. 5. On the VM/Host Groups page, under Configuration, select the vCenter Servers VM Group. 6. In the vCenter Servers Group Members pane, click Add. 7. In the Add Group Member dialog box, select sfo01w02vc01 and click OK.
3.6 Exclude the Compute vCenter Server from the distributed firewall To allow network access to the Compute vCenter Server for the workload domain, exclude it from all distributed firewall rules.
16 VMware NSX-T Workload Domains on VxRail | H17958
3.6.1 Procedure 1. Open a Web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui,
using the vSphere Client with username [email protected] and password vsphere_admin_password.
2. In the Networking and security inventory, click Firewall settings. 3. Click the Exclusion list tab, and, from the NSX Manager drop-down menu, select 172.16.11.65. 4. Click the Add button. 5. The Select VMs to exclude dialog box opens. 6. From the Available objects section, select sfo01w02vc01, add it to the Selected objects section,
and click OK.
3.7 Configure the Shared Edge and compute cluster After you deploy the Compute vCenter Server, you must create and configure the Shared Edge and compute cluster for high availability of and resource usage policy for virtual machines, and for central user management using Active Directory. To create and configure the Shared Edge and compute cluster, perform the following tasks:
Add the ESXi hosts to the Active Directory domain. Create resource pools for the NSX-T edge devices and for the tenant workloads. Create folders for the virtual appliances of the NSX-T Edge devices for inbound and
outbound network traffic in the workload domain.
3.7.1 Procedure
1. Open a Web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
2. Assign Host Licenses 3. Select all ESXi hosts, right-click, select Assign license, select the ESXi license from the
inventory of the License Service, and click OK. 4. Add an ESXi host to the Active Directory domain
a. In the inventory tree, expand the entire sfo01w02vc01.sfo01.rainpole.local tree. b. Select the sfo01w02esx01.sfo01.rainpole.local host. c. On the Configure tab, under System, select Authentication services. d. On the Authentication services page, click the Join Domain button. e. In the Join Domain dialog box, enter the following settings and click OK.
Join Domain Settings Name Value
Domain sfo01.rainpole.local
User Name [email protected]
Password svc-domain-join_password
5. Set the Active Directory service to start and stop with host.
a. On the Configure tab for the host, under System, select Services. b. Select the Active Directory service and click Edit startup policy. c. In the Edit startup policy dialog box, select Start and stop with host and click OK.
6. Create the resource pools for the Shared Edge and compute cluster. Create resource pools for the following components:
17 VMware NSX-T Workload Domains on VxRail | H17958
• NSX-T Edge devices that control the network traffic in and out of the workload domain
• Tenant workloads in the workload domain • NSX-T Edge devices that provide networking services to the tenant workloads in
the workload domain a. Right-click the sfo01-w02-shared01 cluster and select New resource pool. b. In the New resource pool dialog box, enter the values for the sfo01-w02rp-sddc-edge
resource pool and click OK.
Resource Pool Settings Setting Resource Pool 1 Resource Pool 2 Resource Pool 3
Name sfo01-w02rp-sddc-edge
sfo01-w02rp-user-edge sfo01-w02rp-user-vm
CPU-Shares High Normal Normal
CPU-Reservation 0 0 0
CPU-Reservation Type Expandable Selected Expandable Selected Expandable Selected
CPU-Limit Unlimited Unlimited Unlimited
Memory-Shares Normal Normal Normal
Memory-Reservation 32GB 0 0
Memory-Reservation Type Expandable Selected Expandable Selected Expandable Selected
Memory-Limit Unlimited Unlimited Unlimited
c. Repeat the step to add the remaining resource pools.
7. Create a folder for the virtual machines of the NSX-T Edge devices for the inbound and outbound traffic in the workload domain.
a. In the VMs and templates inventory, expand the sfo01w02vc01.sfo01.rainpole.local tree.
b. Right-click the sfo01-w02dc data center and select New folder > New VM and template folder.
c. In the New folder dialog box, enter sfo01-w02fd-nsx and click OK.
18 VMware NSX-T Workload Domains on VxRail | H17958
4 Perform the VxRail initialization to deploy the NSX-T Shared Edge and Compute Cluster
4.1 Overview The NSX-T cluster is deployed through the VxRail initialization wizard. The cluster bring up follows the standard VxRail deployment in which the Management, vSAN, and vMotion networks are deployed along with the ESXi hosts and the defined Cluster.
The VxRail cluster will be joined to the Workload Domain vCenter server that resides in the management domain and provide the platform for the tenant workloads that use the software-defined networking capabilities of NSX-T.
This section provides details for deploying the VxRail cluster for the N-VDS Shared Edge and Compute domain.
The VxRail cluster deployed for NSX-T has different requirements than the Management Domain which is deployed with NSX-V.
The primary difference is the network, and the ability to support NSX-T alongside the vDS that is being deployed for the VxRail cluster. These two constructs must be independent which means that we require additional pNICs for the N-VDS deployment.
In a standard VxRail deployment, a VDS is deployed with VLAN backed port groups for Management, vMotion, and VSAN networks. Additional port groups are added for the NSX-V as shown in Figure 1.
nic0 nic1
VLAN NFS
VLAN vMotion
VLAN vSAN
VxRail ESXi Shared Edge and Compute Host
sfo01-vds01
VLAN ESXi Management
VLAN Trunking Uplink01
VLAN Trunking Uplink02
VXLAN (VTEP)
19 VMware NSX-T Workload Domains on VxRail | H17958
Figure 1 VxRail vDS Network Design
In an N-VDS deployment, the pNICs cannot be shared, so the physical host configuration is designed a bit differently as shown in Figure 2.
Figure 2 VxRail vDS Network Design
This diagram illustrates a couple of points that highlight the difference between NSX-V and NSX-T.
• The first item is that there are now two distributed switches. The vDS provides the network services for the VxRail network services, and the N-VDS provides the network services for the overlay network. The current NSX-T architecture does not permit sharing of the pNICs that support the N-VDS. You must create an additional distributed switch, and N-VDS.
• The second is the number of pNICs has doubled. As an extension to the bullet above the N-VDS
deployment requires a separate set of pNICS for the deployment.
Each VxRail node that will be used as a transport node, must include 4 pNICs which can be either 4 x 10 NDC, or a combination of NDC and PCIe. The first run VxRail Initialization process will deploy a vDS to support the management, vMotion, and VSAN services. The N-VDS will be deployed manually after the VxRail cluster has been deployed.
• The third item is the distribution of port groups for the NSX Overlay. In the NSX-T environment
four VLAN-backed port groups are required for the overlay services. The N-VDS deployed for VVD leverages the host overlay port group for the ESXi or Host Transport zone. The uplink port groups to provide the North-South data paths and an Edge-Overlay port group provides a network for the Edge Services gateways. With the exception of the Edge Overlay, this is consistent with the VLAN requirements for the NSX-V that were used for the Management domain.
20 VMware NSX-T Workload Domains on VxRail | H17958
4.2 Deploy the Shared Edge and Compute VxRail cluster When the vCenter deployment is complete, prepare the vCenter permissions and datacenter for VxRail external vCenter deployment, then perform the deployment of the VxRail Shared Edge and Compute Cluster. The full procedure is listed in the VxRail deployment with external vCenter SolVe procedure.
4.2.1 Before you begin Ensure that the following tasks are complete:
• The Shared Edge and Compute vCenter Server is deployed in Region A. • Network and top-of-rack switches are configured with the required VLANs and BGP peer
interfaces. • A Windows host exists that has access to VxRail Manager within your data center. • (Optional) VxRail deployment JSON file exists.
4.2.2 Procedure Download the VxRail Installation with External vCenter procedure from SolVe Online using
the selections shown in the following figure.
Figure 4 Installation Guide Selections
The SolVe Tool produces the deployment guide with the detailed instructions and dependencies for deploying the VxRail external cluster.
Follow the procedures in the SolVe deployment documentation to complete the Shared Edge and Compute VxRail cluster deployment.
Refer to the information in the following tables for the manual VxRail deployment.
VxRail Manager, vCenter, and Platform Services Controller Details FQDN IP address VLAN ID Default gateway
sfo01w01vxm01.sfo01.rainpole.local 172.16.11.69 1611 172.16.11.253
sfo01m01psc01.sfo01.rainpole.local 172.16.11.63 1611 172.16.11.253
sfo01w01vc01.sfo01.rainpole.local 172.16.11.64 1611 172.16.11.253
21 VMware NSX-T Workload Domains on VxRail | H17958
Management Cluster Hosts FQDN IP address VLAN ID Default
gateway
sfo01w01esx01 … sfo01w01esx04 172.16.31.101 … 172.16.31.104
1631 172.16.31.253
Table 15 vSAN Host Configuration FQDN IP address VLAN ID Default
gateway
sfo01w01esx01 … sfo01w01esx04 172.16.33.101 … 172.16.33.104
1633 172.16.33.253
Table 16 vMotion Host Configuration FQDN IP address VLAN ID Default
gateway
sfo01w01esx01 … sfo01w01esx04 172.16.32.101 … 172.16.32.104
1632 172.16.32.253
After completion of the VxRail Manager deployment, connect to VxRail Manager and confirm the health of the system.
4.3 Rename the VxRail assigned vCenter objects (optional) The VxRail deployment assigns dynamic names to various vCenter components including the Cluster, Network Port Groups, and VSAN Datastore. VxRail allows certain objects to be renamed. This optional task renames the objects to more user-friendly names to support the ease of deployment and use within the SDDC environment.
Log in to the Management vCenter server (entire sfo01w01vc01.sfo01.rainpole.local) Rename the vSAN datastore.
a. In the Navigation pane, click Storage and expand the entire sfo01w01vc01.sfo01.rainpole.local tree.
b. Select the NSX-T workload domain cluster. c. Select vsanDatastore<hex id> and select Actions > Rename. d. In the Datastore - Rename dialog box, enter sfo01-w02-vsan01 as the datastore
name and click OK. Rename the vDS Switch
a. In the navigator, click Networking and expand the sfow01vc01.sfo01.rainpole.local tree.
b. Select the sfo01-w02dc datacenter, and select Networking to display the virtual distributed switch.
c. Right-click the vDS deployed by VxRail. Right-click and select rename. d. On the Name and location page, enter sfo01-w02-vds01 as the name and click Ok.
Rename the VxRail-defined port groups in the sfo01-w02-vds01 distributed switch. a. Select the vDS for the Compute Domain vCenter in Region A. b. Locate each port group that was deployed by VxRail Manager.
c. Right-click the port group and rename using the following table for reference.
22 VMware NSX-T Workload Domains on VxRail | H17958
Port Group Names
Original Group Name New Port Group Name
sfo01-w02-vds01-management-8791111a… sfo01-w02-vds01-management-vxrail sfo01-w02-vds01-vmotion-8791111a… sfo01-w02-vds01-vmotion sfo01-m02-vds01-vsan-8791111a… sfo01-w02-vds01-vsan sfo01-w02-vds01-vcenter server network -8791111a… sfo01-w02-vds01-management sfo01-w02-vds01-VxRail-Manager-8791111a… sfo01-w02-vds01-management-internal
Change the vcenter Server Network binding to ephemeral.
a. Migrate the existing VM NIC of the VxRail manager and other VMs from the vCenter Network port group to the Management Port group.
b. Select the sfo01-w02-vds01-management and right-click Edit Settings. c. Set the Port Binding to Ephemeral. d. Select the Management Network VMs. e. For each VM that was migrated, highlight the VM Edit Settings to set the Network
Adapter back to the vCenter Network port group.
Note: The vCenter Network port group is the recommended management interface for all VMs deployed in the environment.
Enable jumbo frames on the sfo01-w02-vds01 distributed switch. a. Right-click the sfo01-w02-vds01 distributed switch and select Settings > Edit
Settings. b. On the Advanced page, enter 9000 as MTU (Bytes) value and click OK.
Configure the MTU of the ESXi host vMotion VMkernel adapter.
a. Select the vMotion VMkernel adapter and click Edit Settings. b. Click the NIC Settings page. c. Enter 9000 for the MTU value and click OK. d. Repeat this task for each ESXi host.
Set the default gateway for the vMotion Interface a. Select the vMotion VMkernel adapter and click Edit Settings. b. Click the IPv4 Settings page. c. Select the override default gateway for this adapter setting. d. Enter the gateway address for the configured network and click OK. e. Repeat this task for each ESXi host.
4.4 Modify vSphere HA on the Shared Edge and Compute Cluster Modify the vSphere High Availability settings on the cluster.
4.4.1 Procedure
Open a Web browser and log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
In the Navigator, click Host and Clusters and expand the sfo01m01vc01.sfo01.rainpole.local tree.
Select the sfo01-m01-mgmt01 cluster. Click the Configure tab and click vSphere Availability. Click Edit. Click Failures and Responses, modify the following property:
23 VMware NSX-T Workload Domains on VxRail | H17958
vSphere VM Availability Settings
Setting Value
VM Monitoring VM Monitoring Only Click OK.
4.5 Configure SSH advanced options on the ESXi hosts in the Shared Edge and Compute Cluster Enable SSH on all ESXi Hosts to support remote access. To achieve greater levels of security, change the default ESX Admins group and remove a known administrative access point.
4.5.1 Procedure Open a Web browser and log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
Enable SSH. a. In the Hosts and Clusters inventory, expand the sfo01w02vc01.sfo01.rainpole.local
tree. b. Select the sfo01w02esx01.sfo01.rainpole.local host. c. On the Configure tab, select System > Services. d. Select SSH and click the Start button. e. Click the Edit Startup Policy button, select Start and stop with host, and click OK.
Change the default ESX Admins group. a. On the Configure tab, select System > Advanced System Settings. b. Click Edit. c. In the Filter text box, enter esxAdmins. d. Change the value of Config.HostAgent.plugins.hostsvc.esxAdminsGroup to SDDC-Admins.
Disable the SSH warning banner. a. In the Filter text box, enter ssh. b. Change the value of UserVars.SuppressShellWarning to 1 and click OK.
4.6 Configure syslog on the Shared Edge and Compute Cluster To maintain centralized logging, enable the syslog service on the ESXi hosts in the Shared Edge and compute cluster. The syslog service provides a standard mechanism for logging messages from the VMkernel and other system components.
4.6.1 Procedure Open a Web browser and log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui https://sfo01vrli01.sfo01.rainpole.local, using with username admin and the vrli_admin_password
Click the configuration drop-down menu icon and select Administration. Under Integration, click vSphere. In the vCenter Servers pane, enter the connection settings for the vCenter Server instance.
a. Enter the host name, user credentials, and collection options for the vCenter Server instance, and click Test Connection.
24 VMware NSX-T Workload Domains on VxRail | H17958
vCenter Server Connection Settings vCenter Server Option Value
Hostname sfo01w02vc01.sfo01.rainpole.local Username [email protected] Password svc-vrli-vsphere_user_password Collect vCenter Server events, tasks and alarms Selected Configure ESXi hosts to send logs to Log Insight Selected Target sfo01vrli01.sfo01.rainpole.local
b. To verify that you connected to the Compute vCenter Server for the additional workload domain, click Advanced Options and examine the list of ESXi hosts that are connected to the vCenter Server instance.
c. In the Advanced Options configuration window, select Configure all ESXi hosts, select UDP under Syslog protocol, and click OK.
25 VMware NSX-T Workload Domains on VxRail | H17958
5 Deploy the NSX-T instance for the Shared Edge and Compute Cluster
NSX-T Manager implements both the management and central control planes in an NSX-T system. For dynamic routing between the tenant workloads in the domain, deploy a pair of NSX-T Edge nodes. NSX-T Manager also provides the user interface and REST APIs for creating, configuring, and monitoring NSX-T components in a workload domain, such as segments, gateways, and security policies. For high availability of the management and control planes, deploy a cluster of three NSX-T Manager nodes.
5.1 Deploy the First NSX-T Manager Appliance To create a cluster of NSX-T Manager nodes, deploy one NSX-T Manager appliance and configure it. After you complete the configuration of the first node, add the other two nodes of the cluster.
5.1.1 Procedure Open a Web browser and log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
In the Hosts and clusters inventory, expand the sfo01m01vc01.sfo01.rainpole.local tree and expand the sfo01-m01dc data center.
Right-click the sfo01-m01-mgmt01 cluster and click Deploy OVF Template. On the Select template page, navigate to the .ova file of the NSX-T unified appliance, and
click Next. On the Select name and location page, enter the following settings and click Next.
Name and Location Settings
Setting Value
Name sfo01wnsx01a Folder or data center sfo01-m01fd-nsx
On the Select a resource page, select the sfo01-m01-mgmt01 cluster and click Next. On the Review details page, review the extra configuration option message and click Next. On the Select Configuration page, select Large and click Next. On the Select storage page, enter the following settings and click Next.
Storage Settings
Setting Value
Select virtual disk format Thin
VM Storage Policy vSAN Default Storage Policy
Datastore Wld02-vSAN
On the Select networks page, select sfo01-m01-vds01-management as the Destination Network and click Next.
On the Customize template page, enter the following settings, and click Next.
26 VMware NSX-T Workload Domains on VxRail | H17958
Customize Template Settings
Setting Value
System Root User Password / Confirm Password nsx_t_root_password CLI "admin" User Password / Confirm Password nsx_t_admin_password CLI "audit" User Password / Confirm Password nsx_t_audit_password
First NSX Manager Network Details
Setting Value
Host name sfo01wnsx01a.sfo01.rainpole.local Role name nsx-manager nsx-controller Default IPv4 Gateway 172.16.11.253 Management Network IP Address 172.16.11.82 Management Network Netmask 255.255.255.0
NSX Manager Configuration Details
Setting Value
DNS Server List 172.16.11.5 172.16.11.4
Domain Search List sfo01.rainpole.local
NTP Server List ntp.sfo01.rainpole.local
Enable SSH Selected
Allow root SSH login Deselected
On the Ready to complete page, click Finish. After the deployment is complete, power on the NSX-T Manager appliance. a. In the VMs and Templates inventory, expand the sfo01m01vc01.sfo01.rainpole.local
tree. b. Expand the sfo01-m01fd-nsx folder. c. Right-click the sfo01wnsx01a virtual machine, and select Power > Power On.
Log in to the user interface of the first NSX-T Manager appliance https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password
Accept the end-user license agreement and click Continue. Join the VMware Customer Experience Program and click Save. Close the alert stating the management cluster is degraded.
5.2 Import the CA-Signed Certificates for the NSX-T Manager Cluster
After you deploy the first NSX-T Manager appliance and generate the certificates for each NSX-T Manager node and for the virtual IP address of the cluster, import the certificates in to the appliance by using the NSX-T Manager user interface. Later, replace the certificate on each node.
27 VMware NSX-T Workload Domains on VxRail | H17958
Certificate Settings Setting Value for
sfo01wnsx01a Value for sfo01wnsx01b
Value for sfo01wnsx01c
Value for the Cluster Virtual IP
Value for the CA Certificate
Name sfo01wnsx01a sfo01wnsx01b sfo01wnsx01c sfo01wnsx01 Rainpole Root CA
Certificate Contents
sfo01wnsx01a.1.cer sfo01wnsx01b.1.cer sfo01wnsx01c.1.cer sfo01wnsx01.1.cer Root64.cer
Private Key
sfo01wnsx01a.key sfo01wnsx01b.key sfo01wnsx01c.key sfo01wnsx01.key N/A
Password cert_password cert_password cert_password cert_password cert_password
Confirm Password
cert_password cert_password cert_password cert_password cert_password
Service Certificate
No No No No No
5.2.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Import the certificates for the NSX-T Manager appliances and for the virtual IP address of the cluster, and the CA certificate. a. In the Navigator, click System > Certificates. b. Click Import > Import Certificate or Import > Import CA Certificate according to the
type of certificate being imported. c. Enter the values for sfo01wnsx01a from Table 30 and click Import. d. Repeat this step to import all NSX-T Manager and CA Certificates.
On the main navigation bar, click System. In the navigation pane, select Certificates. Select Import > Import Certificate and import the certificate for the first NSX-T Manager
appliance. Repeat the step to import the certificates for the other NSX-T Manager appliances and for
the virtual IP of the cluster. Select Import > Import CA Certificate and import the certificate of the CA on the Active
Directory domain.
5.3 Replace the Certificate for the First NSX-T Manager Appliance
After you deploy the first NSX-T Manager appliance, replace its default certificate to establish a trusted connection with the management components in the SDDC. Replace the existing certificates by using the REST API of NSX-T Manager.
28 VMware NSX-T Workload Domains on VxRail | H17958
5.3.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Retrieve the ID of the certificate. On the main navigation bar, click System. In the navigation pane, select Certificates. Click the ID value of the sfo01wnsx01a certificate and copy it from the text box. Log in to the host that has access to your data center. Replace the default certificate on the NSX-T Manager appliance with the CA-signed
certificate. Start the Postman application in your web browser and log in. On the Authorization tab, enter the following settings and click Update Request.
Authorization Settings Setting Value
Type Basic Auth
User name Admin
Password nsx_admin_password
a. On the Headers tab, add a key by using the following details.
Key Settings Setting Value
Key Content-Type
Key Value Application/xml
b. In the request pane at the top, send the following HTTP request.
HTTP Request Settings Setting Value
HTTP request method
POST
URL https://sfo01wnsx01a.sfo01.rainpole.local/api/v1/node/services/http? action=apply_certificate&certificate_id=sfo01wnsx01a_certificate_ID
After the NSX-T Manager sends a response back, on the Body tab, you see a 202 Accepted
status. Open a Web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
Restart the NSX-T Manager appliance. In the VMs and Templates inventory, expand the sfo01m01vc01.sfo01.rainpole.local > sfo01-m01dc > sfo01-m01fd-nsx tree.
Right-click the sfo01wnsx01a virtual machine, and select Power > Restart Guest OS.
29 VMware NSX-T Workload Domains on VxRail | H17958
5.4 Connect NSX-T Manager to the vCenter Server instances Connect the first NSX-T Manager appliance to the Compute vCenter Server for the workload domain so that tenant workloads can use NSX-T networking components. Connect the first NSX-T to the Management vCenter Server so that you can place the remaining NSX-T Manager nodes on the management cluster later.
vCenter Server Settings Setting Value for the Compute vCenter
Server for the Workload Domain
Value for the Management vCenter Server
Name sfo01w02vc01 sfo01m01vc01
Domain Name or IP Address sfo01w02vc01.sfo01.rainpole sfo01m01vc01.sfo01.rainpole.local
Compute Manager Type vCenter vCenter
User Name [email protected] [email protected]
Password svc-nsxmanager_password svc-nsxmanager_password
5.4.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Add the Compute vCenter Server for the workload domain to NSX-T Manager. On the main navigation bar, click System. In the navigation pane, select Fabric > Compute Managers. Click Add, enter the following values, and click Add.
Compute vCenter Server Settings Setting Value
Name sfo01w02vc01
Domain Name/IP Address sfo01w02vc01.sfo01.rainpole.local
Type vCenter
User name [email protected]
Password svc-nsxmanager_password
To establish a trusted connection to the Compute vCenter Server, verify the thumbprint of the vCenter Server certificate and click Add.
After the connection to the Compute vCenter Server is established, the Compute Managers page shows the following status.
Compute Managers Status Setting Value
Registration Status Registered
Connection Status Up
Repeat the previous step to connect the first NSX-T Manager node to the Management vCenter Server.
30 VMware NSX-T Workload Domains on VxRail | H17958
5.5 Deploy the Remaining Nodes of the NSX-T Manage Cluster Implement high availability of NSX-T Manager by deploying the remaining two nodes of the NSX-T Manager cluster on the management cluster.
5.5.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Overview and click Add Nodes.
The Add Nodes wizard appears. On the Common Attributes page, enter the following settings and click Next.
Common Attributes Settings Setting Value
Compute Manager sfo01m01vc01
Enable SSH Yes
Enable Root Access No
CLI Password / Confirm CLI Password nsx_cli_password
Root Password / Confirm Root nsx_root_password
DNS Servers 172.16.11.5 172.16.11.4
NTP Servers ntp.sfo01.rainpole.local
Form Factor Large
On the Nodes page, enter the following settings to create the sfo01wnsx01b NSX-T Manager node.
NSX-T Node 2 Settings Setting Value
Name sfo01wnsx01b
Cluster sfo01-m01-mgmt01
Datastore sfo01-m01-vsan01
Network sfo01-m01-vds01-management
IP Assignment Type Static
Management IP/Netmask 172.16.11.83/24
Management Gateway 172.16.11.253
To create sfo01wnsx01c, on the Add Node page of the wizard, click Add Node, enter the following settings, and click Finish.
31 VMware NSX-T Workload Domains on VxRail | H17958
NSX-T Node 3 Settings
Setting Value
Name sfo01wnsx01b
Cluster sfo01-m01-mgmt01
Datastore sfo01-m01-vsan01
Network sfo01-m01-vds01-management
IP Assignment Type Static
Management IP/Netmask 172.16.11.84/24
Management Gateway 172.16.11.253
Each NSX-T Manager nodes has a Repository Status equal to Sync Complete, and the status of the management cluster is Stable.
5.6 Create an anti-affinity rule for the NSX-T Manager appliances Create a VM-Host anti-affinity rule to ensure that the NSX-T Manager virtual machines run on different ESXi hosts. If an ESXi host is unavailable, the NSX-T Manager virtual machines on the other hosts continue to provide support for the NSX-T management and control planes.
5.6.1 Procedure Open a Web browser, log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
In the Hosts and clusters inventory, expand the sfo01m01vc01.sfo01.rainpole.local tree and expand the sfo01-m01dc data center.
Select the sfo01-m01-mgmt01 cluster and click the Configure tab. Under the Configuration section, select VM/Host Rules and click Add. In the Create VM/Host Rule dialog box, enter the rule settings and click Add.
Affinity Rule Settings
Setting Value
Name anti-affinity-rule-sfo01wnsx01
Enable rule Selected
Type Separate Virtual Machine
In the Add Rule Member dialog box, select the three NSX-T Manager virtual machines and click OK.
sfo01wnsx01a sfo01wnsx01b sfo01wnsx01c
In the Create VM/Host Rule dialog box, click OK.
5.7 Move the NSX-T Manager appliances to the NSX folder After you deploy the remaining appliances of the NSX-T Manager cluster, move them to the virtual machine folder for NSX and NSX-T.
32 VMware NSX-T Workload Domains on VxRail | H17958
5.7.1 Procedure Open a Web browser, log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
In the VMs and Templates inventory tree, expand the sfo01m01vc01.sfo01.rainpole.local tree.
Drag sfo01wnsx01b and drop it in the sfo01-m01fd-nsx folder. Drag sfo01wnsx01c and drop it in the sfo01-m01fd-nsx folder.
5.8 Replace the certificates for the remaining NSX-T Manager appliances After you deploy the remaining NSX-T Manager appliances, replace the default certificate for them to establish a trusted connection with the management components in the SDDC. To replace the certificate for an NSX-T Manager instance, import the certificates through the NSX-T Manager user interface and replace the existing certificates using a REST API client. Use the CertGenVVD utility to generate a certificate that is signed by a certificate authority (CA) on the parent Active Directory server.
NSX-T Manager Certificate Replacement REST API NSX-T Manager Appliance POST URL for Certificate Replacement
sfo01wnsx01b https://sfo01wnsx01b.sfo01.rainpole.local/api/v1/node/services/http? action=apply_certificate&certificate_id=sfo01wnsx01b_certificate_ID
sfo01wnsx01c https://sfo01wnsx01c.sfo01.rainpole.local/api/v1/node/services/http? action=apply_certificate&certificate_id=sfo01wnsx01c_certificate_ID
5.8.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Retrieve the ID of the certificate for the NSX-T Manager node. a. On the main navigation bar, click System. b. In the navigation pane, select Certificates. c. Click the ID value of the sfo01wnsx01b certificate and copy its value from the text box
that appears. Log in to the host that has access to your data center. Replace the default certificate for the NSX-T Manager appliance with the CA-signed
certificate. a. Start the Postman application in your Web browser and log in. b. On the Authorization tab, configure these settings and click Update Request.
REST API Authorization Settings Setting Value
Type Basic Auth
User name admin
Password nsx_admin_password
33 VMware NSX-T Workload Domains on VxRail | H17958
c. On the Headers tab, enter the header details.
REST API Header Settings Setting Value
Key Content-Type
Key Value Application/xml
d. In the request pane at the top, send the URL query.
REST API URL Settings Setting Value
HTTP request method POST
URL https://sfo01wnsx01b.sfo01.rainpole.local/api/v1/node/services/http? action=apply_certificate&certificate_id=sfo01wnsx01b_certificate_ID
After the NSX-T Manager appliance sends a response back, on the Body tab, you see a 202
Accepted status.
To upload the CA-signed certificate on the sfo01wnsx01c NSX-T Manager appliance, repeat Step 2 to Step 4.
Open a Web browser, log in to vCenter Server, https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
Restart the NSX-T Manager appliances. a. In the VMs and Templates inventory, expand the sfo01m01vc01.sfo01.rainpole.local
> sfo01-m01dc > sfo01-m01fd-nsx tree. b. Right-click the sfo01wnsx01b virtual machine, and select Power > Restart Guest OS. c. Right-click the sfo01wnsx01c virtual machine, and select Power > Restart Guest OS.
In the user interface of NSX-T Manager, verify that the Repository Status for each NSX-T Manager appliance is Sync Complete, and that the status of the management cluster is Stable.
5.9 Assign a virtual IP address and certificate to the NSX-T Manager cluster After you deploy all three NSX-T Manager nodes, assign the virtual IP (VIP) address of the NSX-T Manager cluster and assign a certificate for the VIP address for trusted access to the user interface and API.
5.9.1 Procedure
Log in to the user interface of the first NSX-T Manager appliance https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Assign the virtual IP address to the NSX-T Manager cluster. a. In the Navigator, click System > Overview. b. Click Edit next to Virtual IP, enter 172.16.11.81, and click Save. c. When prompted click Refresh.
Retrieve the ID of the certificate for the NSX-T Manager node. a. On the main navigation bar, click System.
34 VMware NSX-T Workload Domains on VxRail | H17958
b. In the navigation pane, select Certificates. c. Click the ID value of the sfo01wnsx01 certificate and copy its value from the text box
that appears. Log in to the host that has access to your data center. Assign a certificate to the NSX-T Manager cluster.
a. Start the Postman application in your Web browser and log in. b. On the Authorization tab, configure these settings and click Update Request.
Authorization Settings
Setting Value
Type Basic Auth
User name Admin
Password Nsx_admin_password
c. On the Headers tab, enter the header details.
Header Settings
Setting Value
Key Content-Type
Key Value Application/xml
d. In the request pane at the top, from the drop-down menu that contains the HTTP request methods, select POST, and in the URL text box, send the URL query.
Post Settings Setting Value
Key Content-Type
Key Value https://sfo01wnsx01b.sfo01.rainpole.local/api/v1/node/services/http? action=set_cluster_certificate&certificate_id=sfo01wnsx01_certificate_ID
After the NSX-T Manager appliance sends a response back, on the Body tab, you see a 202 Accepted status.
5.10 Assign a Production License to NSX-T Use the user interface of NSX-T Manager to replace the evaluation license for NSX-T with a production one.
5.10.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Licenses. Click Add, enter the license key, and click Add.
5.11 Create the transport zones for system and overlay traffic After you deploy the NSX-T Manager cluster, configure the NSX-T logical networks by creating the
35 VMware NSX-T Workload Domains on VxRail | H17958
transport zones for ESXi management, uplink, and overlay traffic.
NSX-T Logical Network Settings Name N-VDS Name N-VDS Mode Traffic Type
sfo01-w02-uplink01 sfo01-w02-uplink01 Standard VLAN
sfo01-w02-uplink02 sfo01-w02-uplink02 Standard VLAN
sfo01-esxi-vlan sfo01-w02-nvds01 Standard VLAN
sfo01-w02-overlay sfo01-w02-nvds01 Standard Overlay
5.11.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. Navigate to Fabric > Transport Zones and click Add. On the New Transport Zone page, enter the following settings for the first transport zone
and click Add.
Transport Zone Settings Setting Value
Name sfo01-w02-uplink01 N-VDS Name sfo01-w02-uplink01 N-VDS Mode Standard Traffic Type VLAN
Repeat the previous step to create the remaining transport zones.
5.12 Create Uplink Profiles and the Network I/O Control Profile Uplink profiles define the policies for the links from ESXi hosts to NSX-T segments or from NSX Edge nodes to top of rack switches. During network contention, Network I/O Control allocates bandwidth to a system traffic type according to the priority of the traffic.
5.12.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Fabric > Profiles. To define policies for the links between the ESXi hosts and segments and between NSX-T
Edge nodes and top of rack switches, create uplink profiles. a. On the Profiles page, click the Uplink Profiles tab and click Add. b. On the New Uplink Profile page, enter the following values and click Add.
36 VMware NSX-T Workload Domains on VxRail | H17958
Uplink Profile Settings Name Teaming – Teaming
Policy Teamin – Active Uplinks
Transport VLAN
MTU
esxi-w02-uplink-profile Load Balance Source uplink-1,uplink-2 1644 9000
sfo01-w02-overlay-profile Failover Order uplink-1 1649 9000
sfo01-w02-uplink01-profile Failover Order uplink-1 1647 9000
sfo01-w02-uplink02-profile Failover Order uplink-1 1648 9000
In the esxi-w02-uplink-profile profile, create two teaming policies for ECMP uplinks.
a. On the Uplink Profiles tab, select the esxi-w02-uplink-profile profile and click Edit. b. In the Edit Uplink Profile dialog box, under Teamings, click the Add button, enter the
following information, and click Save.
Teaming Policy Settings Name Teaming Policy Active Uplinks
Uplink01 Failover Order Uplink-1
Uplnk02 Failover Order Uplink-2
Include the new teaming policies in the transport zone. a. Navigate to Fabric > Transport Zones, select sfo01-esxi-vlan and click Edit. b. In the Edit Transport Zone dialog box, add Uplink01 and Uplink02 to Uplink Teaming
Policy Names and click Save. Create a Network I/O Control profile for allocating network bandwidth to system traffic and
virtual machine traffic in the workload domains. a. On the Profiles page, click the NIOC Profiles tab and click Add. b. On the New NIOC Profile page, enter the following values.
NOIC Profile Settings Setting Value
Name sfo01-w02-nioc-profile Status Enabled
c. Modify the Host Infra Traffic Resource shares and click Add.
Host Infra Traffic Settings Traffic Type Traffic Name Shares
Fault Tolerance (FT) Traffic 25 vSphere Replication (VR) Traffic 25 iSCSI Traffic 25 Management Traffic 50 NFS Traffic 25 vSphere Data Protection Backup Traffic 25 Virtual Machine Traffic 100 vMotion Traffic 25 vSAN Traffic 100
37 VMware NSX-T Workload Domains on VxRail | H17958
5.13 Create the NSX-T segments for system, uplink, and overlay traffic Create the segments to connect nodes that send VLAN and overlay traffic. Perform this procedure for each segment.
NSX-T Segments Segment Name Uplink & Type Transport Zone VLAN
sfo01-w02-nvds01-uplink01 None sfo01-esxi-vlan 0-4094
sfo01-w02-nvds01-uplink02 None sfo01-esxi-vlan 0-4094
sfo01-w02-uplink01 None sfo01-w02-uplink01 1647
sfo01-w02-uplink02 None sfo01-w02-uplink01 1648
sfo01-w02-overlay None sfo01-esxi-vlan 0-4094
sfo01-w02-ubuntu-01 None sfo01-esxi-vlan 1649
Note: Certain network segments for VxRail are not configured in the NSX-T environment. Those networks for Management, vMotion and VSAN will remain on the vDS network deployed during the VxRail initialization.
5.13.1 Procedure Open a Web browser, log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
On the main navigation bar, click Networking. In the navigation pane, select Segments. On the Segments tab, click Add Segment. Enter the following values for the sfo01-w02-nvds01-uplink01 segment and click Save.
Segment Settings Setting Value
Name sfo01-w02-nvds01-uplink01
Uplink & Type None
Transport Zone sfo01-esxi-vlan
VLAN 0-4094
Repeat this procedure to create the remaining segments. On the main navigation bar, click Advanced Networking and Security. Under Networking, click Switching. Change the teaming policy for sfo01-w02-nvds01-uplink01 and sfo01-w02-nvds01-
uplink02. a. Select sfo01-w02-nvds01-uplink01 and click Edit. b. In the Edit dialog box, select Uplink01 from the Uplink Teaming Policy Name drop-
down menu and click Save. c. Select sfo01-w02-nvds01-uplink02 and click Edit. d. In the Edit dialog box, select Uplink02 from the Uplink Teaming Policy Name drop-
down menu and click Save.
38 VMware NSX-T Workload Domains on VxRail | H17958
5.14 Create a Transport Node Profile Create a transport node profile for the ESXi management and overlay traffic to and from the ESXi hosts in the workload domain. By using this profile, all hosts in the domain have the same transport node configuration.
5.14.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Fabric > Profiles. On the Profiles page, click the Transport Node Profiles tab and click Add. On the General tab of the Add Transport Node Profile dialog box, enter the following
settings.
Transport Node Profile settings Setting Value
Name sfo01-w02-shared01-profile
Transport Zones sfo01-esxi-vlan sfo01-w02-overlay
On the N-VDS tab, under New Node Switch, enter the following settings.
Node Switch Settings
Setting Value
N-VDS Name sfo01-w02-nvds01
NIOC Profile sfo01-w02-nioc-profile
Uplink Profile esxi-w02-uplink-profile
LLDP Profile LLDP [Send Packet Enabled]
IP Assignment Use DHCP
Physical NICs vmnic2 > uplink-1 vmnic3> uplink-2
Click Add to save the profile.
5.15 Configure the ESXi Host Transport Nodes To use NSX-T, configure the ESXi hosts in the Shared Edge and compute cluster as transport nodes. The NSX-T Manager then installs the NSX-T kernel modules on the hosts as VIB files. The NSX-T kernel modules provide services such as distributed routing and distributed firewall.
5.15.1 Procedure Log into the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System.
39 VMware NSX-T Workload Domains on VxRail | H17958
In the navigation pane, select Fabric > Nodes. On the Host Transport Nodes tab, from the Managed by drop-down menu, select
sfo01w02vc01. Select the sfo01-w02-shared01 cluster and click Configure NSX. Select the sfo01-w02-shared01-profile transport node profile and click Save.
Each ESXi host has the following transport node configuration.
Transport Node Settings Setting Value
NSX Configuration Configured
Configuration State Success
Node State Up
Transport Zones sfo01-esxi-vlan sfo01-w02-overlay
NSX Version 2.4.1
N-VDS 1
40 VMware NSX-T Workload Domains on VxRail | H17958
6 Configure dynamic routing in the Shared Edge and Compute Cluster
To support the communication between tenant workloads by using application virtual networks in NSX-T and to connect tenant workloads to the external network, configure dynamic routing in the Shared Edge and compute cluster. Routing occurs in both the North-South and East-West directions. • North-South traffic leaving or entering the workload domain, for example, a virtual machine on
an overlay network communicating with an end-user device on the corporate network. • East-West traffic remains in the workload domain, for example, two virtual machines on the
same or different segments communicating with each other.
6.1 Create an NSX-T Edge Cluster Profile For availability of the routing services and connectivity to the external network, you create a multi-node cluster of NSX-T Edge nodes. To define a common configuration for both NSX-T Edge nodes, you create an edge cluster profile.
6.1.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Fabric > Profiles. On the Edge Cluster Profiles tab, click Add. On the New Edge Cluster Profile page, enter the following values and click Add.
Edge Cluster Profile Settings Setting Value
Name sfo01-w02-edge-cluster01-profile
BFD Probe 1000
BFD Declare Dead Multiple 3
6.2 Deploy the NSX-T Edge appliances To provide tenant workloads with routing services and connectivity to networks that are external to the workload domain, deploy two NSX-T Edge nodes.
NSX-T Edge Node Settings Setting Value for sfo01wesg01 Value for sfo01wesg01 Value for sfo01wesg02
Name sfo01wesg01 sfo01wesg01 sfo01wesg01 sfo01wesg02
Port Groups sfo01-w02vds01-management sfo01-w02vds01-management
Primary IP Address 172.16.41.21 172.16.41.22
41 VMware NSX-T Workload Domains on VxRail | H17958
The following figure illustrates the logical deployment of an Edge Virtual Machine deployed within a VVD on VxRail environment.
There is no management port group within the N-VDS. The management interface for the Edge VM must be assigned to the management network defined for the VxRail cluster.
NSX-T Edge Virtual Machine
fp-eth0 (overlay)
sfo01-w02-uplink01(VLAN)
fp-eth1 (uplink 1)
fp-eth2 (uplink 2)
eth0 (management)
VxRail ESXi Node
sfo01-w02-nvds01sfo01-w02-nvds01
(Overlay)
sfo01-w02-uplink02(VLAN)
sfo01-w02-nvds01-uplink01(VLAN Trunking)
sfo01-w02-overlay(VLAN Trunking)
sfo01-w02-nvds01-uplink02(VLAN Trunking)
sfo01-w02-vds01-management(VLAN 1641)
vmnic0
vmnic1
vmnic2
vmnic3
sfo01-w02-vds01
Figure 3 Edge Virtual Machine logical network design.
6.2.1 Procedure Open a Web browser, log in to vCenter Server,
https://sfo01m01vc01.sfo01.rainpole.local/ui, using the vSphere Client with username [email protected] and password vsphere_admin_password.
In the Hosts and Clusters inventory, expand the sfo01w02vc01.sfo01.rainpole.local tree and expand the sfo01-w02dc tree.
Expand the sfo01-w02-shared01 cluster. Right-click the sfo01-w02rp-sddc-edge resource pool and select Deploy OVF Template. On the Deploy OVF Template page, navigate to the .ova file of the NSX-T Edge appliance
and click Next. On the Select name and location page, enter the following settings and click Next.
Name and Location Settings Setting Value
Name sfo01wesg01
Folder or data center sfo01-w02fd-nsx
On the Select a resource page, select the sfo01-w02rp-sddc-edge resource pool and click Next.
On the Select storage page, select the shared_edge_datastore and click Next. On the Select networks page enter the following and click Next.
42 VMware NSX-T Workload Domains on VxRail | H17958
Network Settings
Source Network Destination Network
Network 3 sfo01-w02-nvds01-uplink02
Network 2 sfo01-w02-nvds01-uplink01
Network 1 sfo01-w02-overlay
Network 0 sfo01-w02-vds01-management* *This port group resides on the workload cluster vDS.
On the Customize template page, expand the setting groups, enter the following settings, and click Next.
User/Password Settings Setting Value
System Root User Password / Confirm Password
nsx_edge_root_password
CLI "admin" User Password / Confirm Password
nsx_edge_admin_password
CLI "audit" User Password / Confirm Password
nsx_edge_audit_password
Need table title Setting Value
Hostname sfo01wesg01.sfo01.rainpole.local
Default IPv4 Gateway 172.16.41.253
Management Network IPv4 Address 172.16.41.21
Management Network Netmask 255.255.255.0
DNS Server 172.16.11.5 172.16.11.4
Domain Search List sfo01.rainpole.local
NTP Server List ntp.sfo01.rainpole.local
Enable SSH Selected
Allow root SSH login Deselected
On the Ready to complete page, click Finish. After the deployment finishes, power on the NSX-T Edge appliance. a. In the VMs and Templates inventory, expand the sfo01w02vc01.sfo01.rainpole.local
tree. b. Expand the sfo01-w02fd-nsx folder, right-click the sfo01wesg01 virtual machine, and
select Power > Power On. Repeat this procedure to deploy the sfo01wesg02 NSX-T Edge appliance.
6.3 Join the NSX-T Edge Nodes to the management plane After you deploy the NSX-T Edge appliances in the Shared Edge and compute cluster, connect them to the NSX-T Manager cluster by joining them to the management plane.
43 VMware NSX-T Workload Domains on VxRail | H17958
Port Group Settings Setting Value for sfo01wesg01 Value for sfo01wesg02
Name sfo01wesg01 sfo01wesg02
Port Groups sfo01-w02-vds01-management* sfo01-w02-vds01-management*
Primary IP Address 172.16.41.21 172.16.41.22
*This port group resides on the workload cluster vDS.
6.3.1 Procedure Log in to the NSX-T Manager cluster Open a Web browser, log in to the NSX-T Manager
cluster https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Retrieve the thumbprint ID of the certificate for the NSX-T Manager cluster by running and copying the output from the command get certificate cluster thumbprint
Log in to the first NSX-T Edge node by using Secure Shell (SSH) client with the following values.
Log in Credentials Setting Value
FQDN sfo01wesg01.sfo01.rainpole.local
User name admin
Password edge_admin_password
Join the NSX-T Edge node to the management plane by running the following command: join management-plane sfo01wnsx01.sfo01.rainpole.local thumbprint thumbprintid username
Enter the password for the admin account. Repeat Step 3 to Step 5 on the sfo01wesg02.sfo01.rainpole.local NSX-T Edge appliance.
6.4 Create an anti-affinity rule for the NSX-T Edge nodes in the Shared Edge and Compute Cluster To ensure that the two NSX-Т Edge appliances run on different ESXi hosts, create a DRS VM-host anti-affinity rule. If a failure occurs on one of the hosts, the appliance on the other host continues providing routing services.
6.4.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with user name admin and password nsx_admin_password.
In the Hosts and Clusters inventory, expand the sfo01w02vc01.sfo01.rainpole.local tree and expand the sfo01-w02dc tree.
Select the sfo01-w02-shared01 cluster and click the Configure tab. Under Configuration, select VM/Host Rules and click Add. In the sfo01-w02-shared01- Create VM/Host Rule dialog box, enter the following settings
and click Add.
44 VMware NSX-T Workload Domains on VxRail | H17958
Anti-Affinity Rule Settings
Setting Value
Name anti-affinity-rule-ecmpedges
Enable rule Selected
Type Separate Virtual Machines In the Add Rule Member dialog box, select the check boxes next to sfo01wesg01 and
sfo01wesg02, and click OK. In the sfo01-w02-shared01- Create VM/Host Rule dialog box, click OK.
6.5 Add the NSX-T Edge Nodes to the transport zones After you deploy the NSX-T Edge nodes and join them to the management plane, connect the nodes to the workload domain by adding them to the transport zones for uplink and overlay traffic, and configure the NVDS switches on each edge node.
6.5.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Fabric > Nodes > Edge Transport Nodes. Select the sfo01wesg01 edge node and click Configure NSX. Under Edit Transport Node - sfo01wesg01, click the General tab. Under Transport Zones, move the following transport zones to the Selected list and click
Add.
Transport Zone Settings Setting Value for sfo01wesg01 Value for sfo01wesg02
Transport Zones sfo01-w02-uplink01(VLAN) sfo01-w02-uplnk02(VLAN) sfo01-w02-overlay (Overlay)
sfo01-w02-uplink01(VLAN) sfo01-w02-uplnk02(VLAN) sfo01-w02-overlay (Overlay)
Under Edit Transport Node - sfo01wesg01, click the N-VDS tab. Under New Node Switch, enter the switch configuration.
New Node Switch Configuration Settings Setting Value for sfo01wesg01 Value for sfo01wesg02
Edge Switch Name sfo01-w02-nvds01 sfo01-w02-nvds01
Uplink Profile sfo01-w02-overlay-profile sfo01-w02-overlay-profile
IP Assignment Use Static IP List Use Static IP List
Static IP List 172.16.49.21 172.16.49.22
Gateway 172.16.49.253 172.16.49.253
Subnet Mask 255.255.255.0 255.255.255.0
Virtual NICs fp-eth0 uplink01 fp-eth0 uplink01
Click Add N-VDS, enter the switch configuration values.
45 VMware NSX-T Workload Domains on VxRail | H17958
N-VDS Switch Configuration Settings
Setting Value for sfo01wesg01 Value for sfo01wesg02
Edge Switch Name sfo01-w02-nvds01-uplink01 sfo01-w02-nvds01-uplink01
Uplink Profile sfo01-w02-uplink01-profile sfo01-w02-uplink01-profile
IP Assignment Greyed Out Greyed Out
Virtual NICs fp-eth0 uplink01 fp-eth0 uplink01
Click Add N-VDS, enter the values, and click Save.
N-VDS Settings Setting Value for sfo01wesg01 Value for sfo01wesg02
Edge Switch Name sfo01-w02-nvds01-uplink02 sfo01-w02-nvds01-uplink02
Uplink Profile sfo01-w02-uplink02-profile sfo01-w02-uplink02-profile
IP Assignment Greyed Out Greyed Out
Virtual NICs fp-eth0 uplink01 fp-eth0 uplink01
Repeat the step on sfo01wesg02. The edge transport nodes have the following configuration:
Edge Transport Node Settings Setting Value for sfo01wesg01 Value for sfo01wesg02
Edge sfo01wesg01 sfo01wesg02
Management IP 172.16.41.21 172.16.41.22
Configuration State Success Success
Node Status Up Up
Transport Zones • sfo01-w02-overlay • sfo01-w02-uplink01 • sfo01-w02-uplink02
• sfo01-w02-overlay • sfo01-w02-uplink01 • sfo01-w02-uplink02
N-VDS 3 3
6.6 Create an NSX-T Edge Cluster Adding multiple NSX-T Edge nodes to a cluster increases the availability of networking services. An NSXT Edge cluster is necessary to support the Tier-0 and Tier-1 gateways in the workload domain.
6.6.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation pane, select Fabric > Nodes. On the Edge Clusters tab, click Add.
46 VMware NSX-T Workload Domains on VxRail | H17958
In the Add Edge Cluster dialog box, configure the following settings.
Edge Cluster Settings Setting Value
Name sfo01-w02-edge-cluster01
Edge Cluster Profile sfo01-w02-edge-cluster01-profile
From the Member Type drop-down menu, select Edge Node. Move the sfo01wesg01.sfo01.rainpole.local and sfo01wesg02.sfo01.rainpole.local nodes to
the selected list. Click OK and click Add.
6.7 Create and configure the Tier-0 gateway The Tier-0 gateway in the NSX-T Edge cluster provides a gateway service between the logical and physical network. The NSX-T Edge cluster can back multiple Tier-0 gateways.
6.7.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Create the Tier-0 gateway. a. On the main navigation bar, click Networking. b. Select Tier-0 Gateways and click Add Tier-0 Gateway. c. Enter the following values and click Save.
Tier-0 Gateway Settings Setting Value
Name sfo01-w02-tier-0-01
High Availability Mode Active-Active
Edge Cluster sfo01-w02-edge-cluster01
Confirm that you want to continue configuring the Tier-0 gateway. Configure route redistribution.
a. Expand Route Re-Distribution and click Set. b. Select all sources and click Apply.
Add the uplink interfaces to the NSX-T Edge nodes. a. Expand Interfaces and click Set. b. In the Set Interfaces dialog box, click Add Interface and enter the settings of the uplink
User Interface Settings Name Type IP Address / Mask Connected To
(segment) Edge Node MTU
sfo01wesg01-Uplink01 External 172.16.47.2/24 sfo01-w02-uplink01 sfo01wesg01 9000
sfo01wesg01-Uplink02 External 172.16.48.2/24 sfo01-w02-uplink02 sfo01wesg01 9000
sfo02wesg01-Uplink01 External 172.16.47.3/24 sfo01-w02-uplink01 sfo01wesg02 9000
sfo02wesg01-Uplink02 External 172.16.48.3/24 sfo01-w02-uplink02 sfo01wesg02 9000
47 VMware NSX-T Workload Domains on VxRail | H17958
c. Click Save. d. Repeat this step for the other interfaces and click Close.
Configure BGP. a. Expand BGP, enter the following settings, and click Save.
BGP Settings Setting Value
Local AS 65000
BGP On
Graceful Restart Off
Inter SR iBGP On
ECMP On
Multipath Relax on
b. Click Set for BGP Neighbors. c. In the Set BGP Neighbors dialog box, click Add BGP Neighbor and enter the following
settings for the first Layer 3 device.
Layer 3 Device Settings IP address BFD Remote
AS Hold down Time
Keep Alive Time
Password
172.16.47.1 Disabled 65001 12 4 bgp_password
172.16.48.1 Disabled 65001 12 4 Bgp_password
Note: Enable BFD only if the network supports and is configured for BFD.
Repeat for the other neighbor, click Save and click Close. Click Close Editing.
6.7.2 Generate a BGP summary for the Tier-0 gateway. 6.7.2.1 Procedure
In the main navigation bar, click Advanced Networking & Security. Select Routers and select sfo01-w02-tier-0-01. Select Actions > Generate BGP Summary. Verify the Connection Status of each transport node is Established.
6.8 Create and configure the Tier-1 gateway Create and configure the Tier-1 gateway to re-distribute routes to the Tier-0 gateway and to provide routing between tenant workloads.
Tier-1 gateways have downlink ports to connect to NSX-T segments and uplink ports to connect to NSX-T Tier-0 gateways.
48 VMware NSX-T Workload Domains on VxRail | H17958
6.8.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
Create the Tier-1 gateway. a. On the main navigation bar, click Networking. b. Select Tier-1 Gateways and click Add Tier-1 Gateway. c. Enter the configuration of the Tier-1 gateway.
Tier-1 Gateway Configuration Settings Setting Value
Name sfo01-w02-tier-1-01
Linked Tier-0 Gateway sfo01-w02-tier0-01
Failover Preemptive
Edge Cluster sfo01-w02-edge-cluster-01
d. Next to Edges, click Set. e. In the Select Edges dialog box, click Add Edge. f. Add the sfo01wesg01 and sfo01wesg02 edge nodes and click Apply.
Confirm that you want to continue configuring the Tier-1 gateway. Expand Route Advertisement, enable all types, and click Save. Verify the connection between the Tier-1 and Tier-0 gateways.
a. On the main navigation bar, click Advanced Networking & Security. b. Select Routers. c. Select the sfo01-w02-tier-1-01 gateway. d. Select Configuration > Router Ports and verify that the existing Linked Port has the
following settings.
Linked Port Settings Setting Expected Value
Logical Router LinkedPort_sfo01-w02tier-0-01
Type Linked Port
IP Address/mask x.x.x.x/31
Connected To sfo01-w02-tier-0-01
Transport Node • sfo01wesg01, • sfo01wesg02
e. Select the sfo01-w02-tier-0-01 gateway. f. Select Configuration > Router Ports, and verify that the existing Linked Port has the
following settings.
49 VMware NSX-T Workload Domains on VxRail | H17958
Router Port Settings Setting Expected Value
Logical Router LinkedPort_sfo01-w02-tier-0-01
Type Linked Port
IP Address/mask x.x.x.x/31
Connected To sfo01-w02-tier-0-01
Transport Node -
6.9 Verify BGP peering and route redistribution The Tier-0 gateway must establish a connection to each of the upstream Layer 3 devices before BGP updates can be exchanged. Verify that the NSX-T Edge nodes are successfully peering and that BGP routing is established.
6.9.1 Procedure Log in to sfo01wesg01 by using a Secure Shell (SSH) client and the following settings.
Log in Credentials
Setting Value
FQDN sfo01wesg01
User name admin
Password nsx_edge_admin_password
Get information about the Tier-0 and Tier-1 service routers and distributed router using the following command: get logical-router. For example, the output of the command might contain the following configuration:
Command Output Example UUID VRF LR-ID Name Type Ports
sample_uuid 0 0 TUNNEL 3
Type 1 5 SR-tier0-01 SERVICE_ROUTER_TIER0 6
IP Address/ mask 2 2 DR-tier1-01 DISTRIBUTED_ROUTER_TIER1 5
Connected To 3 3 DR-tier0-01 DISTRIBUTED_ROUTER_TIER1 4
Transport Node 4 11 SR-tier1-01 SERVICE_ROUTER_TIER0 5
Use the VRF value for SERVICE_ROUTER_TIER0 to connect to the service router for Tier 0. vrf 1 The prompt changes to hostname (tier0_sr)>. All commands are associated with this object.
Verify the BGP connections to the neighbors of the service router for Tier 0. get bgp neighbor
The BGP State for each neighbor appears as Established, up for hh:mm:ss. Verify that you are receiving routes by using BGP and that multiple routes to BGP-learned
networks exist using the following command: get route Repeat this procedure on sfo01wesg02.
50 VMware NSX-T Workload Domains on VxRail | H17958
7 Deploy a segment for a sample tenant workload Create logical segments and connect them to the Tier-1 gateway for your tenant workloads. For example, you can create a segment for Ubuntu workloads and connect it to the Tier-1 gateway.
7.1.1 Procedure Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with username admin and password nsx_admin_password.
On the main navigation bar, click Networking. In the navigation pane, select Segments. On the Segments tab, next to the sfo01-w02-ubuntu-01 segment, click the vertical ellipsis
icon and click Edit. Change the Uplink & Type from Isolated - Flexible to sfo01-w02-tier1-01 | Tier 1. Assign a subnet to the segment.
a. Click Set Subnets. b. In the Set Subnets dialog box, click Add Subnet, enter 192.168.200.1/24, click Add,
and click Apply. In the segment pane, click Save.
7.1.2 What to do next After you place workloads on the new segment by connecting them to the segment port group in vSphere, configure 192.168.200.1 as the default gateway for the workloads.
51 VMware NSX-T Workload Domains on VxRail | H17958
8 Connect vRealize Log Insight to the NSX-T instance for the Shared Edge and Compute Cluster
After you deploy the NSX-T components in the new workload domain, connect vRealize Log Insight to the NSX-T instance to start collecting log information.
8.1 Configure the NSX-T components to forward log events to vRealize Log Insight Configure the NSX-T Manager and NSX-T Edge nodes to send audit logs and system events to vRealize Log Insight.
Repeat this procedure for the following NSX-T components.
NSX-T Components NSX-T Component Hostname
Managers sfo01wnsx01a.sfo01.rainpole.local sfo01wnsx01b.sfo01.rainpole.local sfo01wnsx01c.sfo01.rainpole.local
Edges sfo01wesg01.sfo01.rainpole.local sfo01wesg02.sfo01.rainpole.local
8.1.1 Procedure Open an SSH connection to the first NSX-T Manager appliance. Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with user name admin and password nsx_admin_password.
To set up log forwarding to vRealize Log Insight, run the following command. set logging-server 192.168.31.10 proto udp level info
Тo verify that log forwarding is configured, run the following command. get logging-servers
Repeat the procedure for all NSX-T Manager and NSX-T Edge nodes.
52 VMware NSX-T Workload Domains on VxRail | H17958
9 Back Up and Restore the NSX-T Instance for the Shared Edge and Compute Cluster Back up the NSX-T Manager cluster so that you can restore its operation and modify the NSX-T configuration in the workload domain after failures. The NSX-T Manager cluster stores the configured state of the segments. If the NSX-T Manager appliances become unavailable, the network traffic in the data plane is intact, but you cannot make any configuration changes.
9.1 Configure automatic backups of the NSX-T configuration Configure NSX-T Manager to store daily configuration backups to a Secure File Transfer Protocol (SFTP) server. The NSX-T configuration backup contains the NSX-T Manager nodes backup, cluster backup, and inventory backup.
9.1.1 Procedure In a Web browser, log in to the user interface of NSX-T Manager. Log in to the user interface of the first NSX-T Manager appliance
https://sfo01wnsx01a.sfo01.rainpole.local with user name admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation page, select Backup & Restore. On the Backup tab, click Edit. On the File Server page, enter the following values and click Save.
Backup and Restore Settings Setting Value
Automatic Backup Enabled
IP/Host nsx_backup_server Port 22 Protocol SFTP User name sftp_username Password sftp_password Destination Directory backup_directory Backup encryption passphrase password_for_backups SSH fingerprint Leave blank to fetch fingerprint automatically.
.
On Schedule tab, configure the following settings and click Save.
53 VMware NSX-T Workload Domains on VxRail | H17958
Schedule Settings Setting Value
Automatic Backup Enabled
Frequency Weekly Days All days
Time 22:00 Detect NSX configuration change Enabled Update Interval 5 min
9.2 Restore the NSX-T Manager Cluster If the NSX-T Manager cluster for the workload domain becomes unavailable, deploy another NSX-T Manager cluster and use a backup to import the configuration. Restore the following configuration:
• State of the network • Configuration that is maintained by the NSX-T Manager cluster
After you restore the NSX-T Manager cluster, you must apply again the changes, such as adding or deleting nodes, made to the fabric after the backup is taken.
Important! Do not change the configuration of the NSX-T Manager cluster while the restore process is in progress.
9.2.1 Procedure Power off the original NSX-T Manager appliances and deploy a new NSX-T Manager
cluster. The new and original NSX-T Manager cluster appliances must have the same product version and the management IP addresses.
Log in to the user interface of the first NSX-T Manager appliance https://sfo01wnsx01a.sfo01.rainpole.local with user name admin and password nsx_admin_password.
On the main navigation bar, click System. In the navigation page, select Backup & Restore. On the Restore tab, click Edit. On the File Server page, enter the following values and click Save.
Restore Settings Setting Value
IP/Host nsx_backup_server
Port 22 Protocol SFTP User name sftp_username Password sftp_password Destination Directory backup_directory Backup encryption passphrase password_for_backups SSH fingerprint Leave blank to fetch fingerprint automatically.