38
VINTAGE PARTS MARKETING PRODUCT LINE: CHTA - CA HERITAGE COMPANY: IR CONFIGURATION: Barrel - diffuser TYPICAL APPLICATION: Boiler Feed Pump VINTAGE: 1959 - current PRODUCT LIFESPAN: Undefined SUBJECT: Engineering Information The CA developed into the CHTA as the product line expanded. This product is still sold today. The CHTB and CHTC manufactured by KSB are very similar, since KSB licensed this product. NOTE: This information is intended for the use of Flowserve Employees. The information provided is based on standard catalogue / price book information. Details for specific units or serial numbers may be different as a result of non-standard construction, and parts, repairs and upgrades provided by Flowserve or third parties.

Upload: others

Post on 14-Mar-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

VINTAGE PARTS MARKETING PRODUCT LINE: CHTA - CA HERITAGE COMPANY: IR CONFIGURATION: Barrel - diffuser TYPICAL APPLICATION: Boiler Feed Pump VINTAGE: 1959 - current PRODUCT LIFESPAN: Undefined SUBJECT: Engineering Information The CA developed into the CHTA as the product line expanded. This product is still sold today. The CHTB and CHTC manufactured by KSB are very similar, since KSB licensed this product. NOTE: This information is intended for the use of Flowserve Employees. The information provided is based on standard catalogue / price book information. Details for specific units or serial numbers may be different as a result of non-standard construction, and parts, repairs and upgrades provided by Flowserve or third parties.

Pump Division

Feature Standard Optional Notes

CCW Rotation (Per HI) XForged Barrel XForged Discharge Nozzle XCast Suction Nozzle XForged Suction Nozzle X Subject to engineering review.Flanged Nozzle Connections XWeld-Prep Nozzle Connections X Welded discharge standard on supercritical.Standard Bolting XSuperbolts X Standard on 80CHTA and above for subcritical,

65CHTA and above for supercritical.1.25% Chrome Barrel See Notes Standard on 80CHTA and below. Not available

for larger sizes.Carbon Steel Barrel with Stainless Inlay See Notes Standard on 95CHTA and above, optional for

other sizes.Top-Top Nozzles XOther Nozzle Configuration XIntermediate Pressure Takeoff XPump Drain Connection w/Valve X Not required for bottom-bottom nozzles.Pump Vent Connectin w/Valve X Only required for bottom-bottom nozzles.Flanged Balance Line Connection X Bal. line piped upstream by customer.Gauge Connections X Not recommended for any supercritical

application. Not available for down-down nozzles.

Single Suction XDouble Suction XSuperstraight Shaft Material XKeyed & Shrink Fit Impellers XRingless Impellers X With serrated hubs.Casing Wear Rings XImpeller Rings X Not offered on high-speed applications.DLD of Impeller Hubs X As determined by engineering.Dynamically Balanced Impellers XDynamically Balanced Rotor XFlanged Drum Balance Device XStraight Drum Balance Device X Subject to engineering approval.DLD of Balance Device X As determined by engineering."Kicker" Stage XSleeve Radial Bearings (Tri-Land) XTilting-Pad Type Thrust Bearing X360-Degree Bearing Housing Bolting XMechanical Seals X Subject to application limitations.Controlled Leakage Labyrinth Seals XPlan 23 Seal Flush Piping See Notes Standard if Mechancial Seals are supplied.Seal Injection Control System See Notes Standard if Labyrinth Seals are supplied.Flexible Disc Spacer Coupling XFlexible Diaphragm Coupling X

Standard and Optional Construction - Model CHTA & CA

Feature Standard Optional Notes

Keyed Coupling XHydraulic Fit Coupling XCoupling Guard X By turbine supplier if oil-tight guard required.Lube Oil Piping X Scope to be determined by drive arrangement.Cooling Water Piping X Dependent on shaft seal & driver type.Provision for Proximity Probes XVibration Instrumentation XBearing RTDs XCasing Thermocouples X Required by Flowserve to monitor warming.Landing Bars X Mounting must be reviewed per inquiry.Steel Pedestals X Mounting must be reviewed per inquiry.Single Element Baseplate X Mounting must be reviewed per inquiry.Multiple Element Baseplate X Mounting must be reviewed per inquiry.Flowserve Standard Visual Inspection XNDE Per Customer Specification XNon-Witnessed Hydrostatic Test XNon-Wit. Reduced Speed Perf. Test X Shop ambient temperature water.NPSH Test X Shop ambient temperature water.Hot Performance/NPSH Test X Subject to test stand limitations.Full Speed Performance Test X Subject to test stand limitations.Witnessed Testing XLateral Critical Speed Analysis XTrain Torsional Analysis XOther Engineering Analysis XAcoustic/Thermal Insulation Blanket XWarming Orifice XDismantle Cradle & Special Tools X One cradle & set of tools per pump type.Dismantle Carriage XChemical Cleaning Plates X

VINTAGE PARTS MARKETING PRODUCT LINE: CHTA - CA HERITAGE COMPANY: IR CONFIGURATION: Barrel - diffuser TYPICAL APPLICATION: Boiler Feed Pump VINTAGE: 1959 - current PRODUCT LIFESPAN: Undefined SUBJECT: Other Pre-Engineered, BOM,

Interchangeability, etc. The CA developed into the CHTA as the product line expanded. This product is still sold today. The CHTB and CHTC manufactured by KSB are very similar, since KSB licensed this product. NOTE: This information is intended for the use of Flowserve Employees. The information provided is based on standard catalogue / price book information. Details for specific units or serial numbers may be different as a result of non-standard construction, and parts, repairs and upgrades provided by Flowserve or third parties.

Pump Division

Approximate Dimensions – Model CHTA & CA

B R PUMP SIZE

FIRST (1) STAGE TYPE

E F A C D G W

(FOR THREE STAGE PUMPS)

ADD FOR ADDITIONAL

STAGES

6 X 13 SS 29 36 41 25 10

42

76 13.125 70 6.125

DS 28 11.875

65 SS 32 40 40 26 10 45 78 13.875 72 6.125

DS 27.5 12.5

75 SS 33 42 41 26 11 51 80 14.5 76 6.375

DS 30.5 13.25

80 SS 40 44 45 31.5 12 56 86 19.125 83 6.750

DS 36 20

85 SS 40 44 50 30.5 12 56 86 14.75 83 6.500 DS 35 14.375

10 X 16 SS 40 44 48 30 12 57 86 16.5 85 7.250

DS 34.5 15

95 SS 44 48 53 31.5 12 61 90 16.375 85 7.375

DS 36 14.75

100 SS 44 48 48 31.5 13 64 92 16.625 85 7.250

DS 37.5 15.5

12 X 18 SS 47 52 59 36.5 13 73 104 16.5 97 7.375

120 DS 48 54 58 39.5 13 75 104 14.5 98 7.750

130 DS 44 56 60 43.5 13 77 108 25.375 116 9.375

Notes: 1) SS = Single Suction; DS = Double Suction 2) Dimensions not shown above must be obtained from proposed driver drawings. 3) A lube oil console sized for pump or pump & motor typically adds 48” to the baseplate length. 4) All dimensions above are inches.

Pump Division

Approximate Pump Weights – Model CHTA & CA

PUMP ROTOR PUMP SUPPORT

ST SHOWN ST SHOWN BASEPLATE PEDESTALS PUMP -

STAGES SS DS

ADD ST

SS DS

ADD ST PUMP

ONLY ADDITIONAL

ELEMENT PUMP ONLY

6X13 - 4 12500 13500 960 2750 2950 500 5000 4000 65 - 4 16000 17800 1300 3400 3750 520 5000 4000 75 - 4 18500 19900 1330 3900 4200 800 5000 5000 2000 80 - 4 30000 33000 2350 5000 5500 1260 2000

80 (LS) - 4 33600 37300 2630 5600 6100 1300 2000 85 - 4 35300 38100 2740 5600 6100 1250 2000

10X16 - 4 35000 37800 2650 6300 6800 1300 2500 95 - 3 34750 37500 2700 4900 5400 1300 2500 100 - 3 36000 39400 5000 5100 5500 1640 2500

12X18 - 3 44000 48800 5400 5300 5800 1620 3000 120 - 3 52000 58300 6000 7650 8300 1650 3000 130 - 3 58800 6500 8500 1700

20X25 - 3

107000 14000

12300 2750

Notes: 1) All weights are in pounds. 2) The above data for sizes 6X13 through and including 100 is based on sub-critical boilers. For super-critical boilers add 25% or contact customer services.

VINTAGE PARTS MARKETING PRODUCT LINE: CHTA - CA HERITAGE COMPANY: IR CONFIGURATION: Barrel - diffuser TYPICAL APPLICATION: Boiler Feed Pump VINTAGE: 1959 - current PRODUCT LIFESPAN: Undefined SUBJECT: Installation Lists The CA developed into the CHTA as the product line expanded. This product is still sold today. The CHTB and CHTC manufactured by KSB are very similar, since KSB licensed this product. NOTE: This information is intended for the use of Flowserve Employees. The information provided is based on standard catalogue / price book information. Details for specific units or serial numbers may be different as a result of non-standard construction, and parts, repairs and upgrades provided by Flowserve or third parties.

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

1959Initec / Sevillana de

ElectricidadCadiz 2 370 2 40CHTA-7 1,215 6106 4,300 Motor driven

1959Initec / Hidroeléctrica del

CantábricoSoto Ribera 1 67.6 2 40CHTA-4 1,453 4,072 5,000 Motor driven

1962 Carolina P&L Co.Asheville SE Plant #1

(Skyland, NC)2 50CHTA-7 1,735 5,200 3,570

1962 Virgina Electric & Power Co.Chesterfield Power Station

#61 100CHTA-6 5,869 7,251 3,510

1962 Indiana & Michigan Electric Tanners Creek Unit #4 1 120CHTA-5 8,898 11,178 4,500

1962 Indiana & Michigan Electric Tanners Creek Unit #4 1 120CHTA-5 8,898 11,178 4,500

1963Pennsylvania Power & Light

Co.3 60CHTA-10 2,179 7,015 3,460

1963 Virginia Electric & Power Co.Mount Storm Power Station

#12 100CHTA-6 4,896 7,287 3,500

1963 Virginia Electric & Power Co.Mount Storm Power Station

#11 100CHTA-6 4,896 7,287 3,500

1963 Virginia Electric & Power Co.Mount Storm Power Station

#12 100CHTA-6 4,896 7,287 3,500

1963 Conn Edison Co. of New York Ravenswood Unit #3 1 125CHTA-6 8,000 7,720 3,500

POWER Generation and Desalination FLT

Page 1 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1963 Conn Edison Co. of New York Ravenswood Unit #4 1 125CHTA-6 8,000 7,720 3,500

1963 Southern California Edison Etiwanda Units #3 & #4 2 100CHTA-6 6,098 7,651 3,510

1963 Florida Power & Light Co. Cape Canaveral Plant #1 2 85CHTA-7 3,351 7,402 3,570

1963 Florida Power & Light Co.Port Everglades Station #3

and #42 85CHTA-7 3,351 7,402 3,570

1963 Hartford Elec. Light Co. 1 85CHTA-6 3,641 8,661 4,100

1963 Ohio Power Co. Cardianal Unit #1 & #2 2 120CHTA-5 9,497 11,601 4,630

1963 IR Austraila Ltd. 3 50CHTA-5 2,144 6,870 4,760

1964 Georgia Power Company 1 65CHTA-10 2,624 6,831 3,450

1964 Gulf States Utilities Co. Sabine Unit #3 1 85CHTA-8 3,650 7,201 3,470

1964 Georgia Power Co. 1 95CHTA-8 5,900 7,349 3,475

1964 Carolina Power & Light Co.Roxboro Steam Electric

Plant1 95CHTA-7 6,058 6,460 3,490

Page 2 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1964 Gulf States Utilities Co. Sabine Unit #3 1 85CHTA-8 3,800 7,201 3,600

1964 Damodar Valley Corporation Chandrapura Thermal 3 40CHTA-7 1,242 5,801 4,475

1964 Union Electric Co. of Missouri Sioux Power Mount Unit #1 1 120CHTA-5 8,449 11,880 4,590

1964 Damodar Valley Corporation Calcutta, India 3 40CHTA-7 1,303 6,152 4,660

1964 ECNSWMunmorah Power Station

Unit #12 85CHTA-4 5,500 7,110 4,855

1964 ECNSWMunmorah Power Station

Unit #22 85CHTA-4 5,500 7,110 4,855

1964 IR Austrailia Ltd.Munmorah Power Station

Unit #14 50CHTA-4 2,752 7,110 5,650

1964 IR Austrailia Ltd.Munmorah Power Station

Unit #24 50CHTA-4 2,752 7,110 5,650

1964 Union Electric Co. of Missouri Sioux #1 1 65CHTA-5 4,222 10,600 5,650

1964Initec / Hidroeléctrica del

CantábricoSoto Ribera 2 254 2 50CHTA-5 2,113 6,906 4,700 Motor driven

1964 Initec / Iberduero Pasajes 1 214 1 65CHTA-7 2,862 7,379 4,250 Turbine driven

Page 3 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1964 Initec / Iberduero Pasajes 1 214 2 40CHTA-7 1,220 6,217 4,450 Motor driven

1965 Long Island LightingNorht Port Power Station

Unit #11 100CHTA-6 6,287 7,300 3,500

1965 Long Island LightingNorht Port Power Station

Unit #21 100CHTA-6 6,287 7,300 3,500

1965 IR Canada Scott Maritimes Pulp Ltd. 1 50CHTA-4 1,471 3,081 3,580

1965 IR Canada Scott Maritimes Pulp Ltd. 1 50CHTA-4 1,471 3,081 3,570

1965 Iberduero Pasajes l 1 65CHTA-7 3,060 6,804 4,250

1965 Ontario Hydro Labton Generating Station 3 100CHTA-4 8,101 7,159 4,250

1965 Ontario Hydro Labton Generating Station 1 100CHTA-4 8,101 7,159 4,250

1965The Israel Electric Corportation

Ltd.Haifa Power Station Units

3&44 40CHTA-8 1,242 6,300 4,500

1965 Ohio Power Co. Musking River Plant Unit #5 1 120CHTA-5 9,497 11,601 4,560

1965 Union Electric Co. of Missouri Sioux Power Mount Unit #2 1 120CHTA-5 8,449 11,880 4,590

Page 4 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1965 Electrica de Viesgo Soto Ribera ll 2 50CHTA-5 2,100 5,771 4,696

1965 Enel / Italy La Spezia Units #1 & #2 2 95CHTA-5 8,929 11,529 5,460

1965 Union Electric Co. of Missouri Sioux Power Plant Unit #2 1 65CHTA-5 4,222 10,600 5,650

1965 Detroit Edison Company Trenton Channel Unit #9 2 65CHTA-4 4,500 6,591 5,750

1965 Commonwealth Edison Kincaid Station Unit #1 1 85CHTA-4 5,090 9,019 5,875

1965 Commonwealth Edison Kincaid Station Unit #1 1 85CHTA-4 5,090 9,019 5,875

1965 Commonwealth Edison Kincaid Station Unit #2 1 85CHTA-4 5,090 9,019 5,875

1965 Commonwealth Edison Kincaid Station Unit #2 1 85CHTA-4 5,090 9,019 5,875

1966 Virginia Electric & Power Co.Chesterfield Power Station

#61 100CHTA-6 5,543 6,529 3,500

1966 Initec / Iberduero Santurce 1 377 2 65CHTA-7 1,198 7,707 4,750 Turbine driven

1966 Initec / Iberduero Santurce 1 377 1 50CHTA-7 2,078 7,379 4,250 Motor driven

Page 5 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1966 United Illuminating Co.Bridgeport Harbor Station

Unit #31 65CHTA-8 1,810 6,631 3,570

1966 Taiwan Power Co. Lin Kou Unit #1 3 65CHTA-11 2,356 7,999 3,580

1966 United Illuminating Co.Bridgeport Harbor Station

Unit #31 100CHTA-6 6,340 7,530 3,620

1966 International General Electric Station Santurce l 1 65CHTA-7 2,778 7,549 4,750

1966 International General Electric Station Santurce l 1 65CHTA-7 2,778 7,549 4,750

1966 Americal Electric Power Co. Big Sandy Plant #2 1 130CHTA-4 12,548 11,300 4,840

1966 Klein, Schantglin & Rocket AGNiederaussen Power

Station2 85CHTA-4 4,707 9,334 4,900

1966 Detroit Edison Company St. Clair #7 1 95CHTA-4 9,299 6,601 4,990

1966 New England Power Brayton Point Station #3 1 95CHTA-5 9,259 11,460 5,500

1966 Consolidated Edison Co. of NY Arthur Kill Unit #3 2 65CHTA-4 4,500 6,591 5,750

1966 Gulf States Utilities Co. Roy S. Nelson Unit #4 2 85CHTA-4 4,760 11,325 5,775

Page 6 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1966 Carolina Power & Light Co.Roxboro Steam Electric

Plant #22 75CHTA-4 5,500 7,231 5,950

1967 Virginia Electric & Power Co.Chesterfield Power Station

#61 130CHTA-5 12,130 7,490 3,500

1967 American Electric Power Corp Mitchell Plant #1 1 130CHTA-4 12,548 7,490 4,840

1967 Tennessee Valley Authority Paradise Stream Plant #3 2 95CHTA-5 9,000 11,401 5,450

1967 Gulf States Utilities Co. Willow Glen Unit #3 2 85CHTA-5 4,760 11,325 5,775

1967 Florida Power Co. Crystal River Plant Unit #2 2 65CHTA-4 4,258 7,490 5,920

1967 Arkansas Power & Light Co.Lake Catherine Steam

Electric Station2 65CHTA-4 4,561 7,500 5,975

1968 American Electric Power Corp Mitchell Plant #2 1 130CHTA-4 12,548 11,300 4,840

1968 Louisiana Power & LightNinemile Pt Steam Electric

Station #42 80CHTA-6 6,569 11,300 5,600

1968 Tennessee Valley Authority Cumberland 1 & 2 4 12x18 CA 10,699 10,509 5,800

1968 Detroit Edison Co. Monroe Unit #1 2 80CHTA-6 6,261 12,500 5,800

Page 7 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1968 Detroit Edison Co. Monroe Unit #2 2 80CHTA-6 6,261 12,500 5,800

1968 Standard Oil Co. of California El Segundo Modern Project 1 80CHTA-6 1,792 6,578 5,850

1968 Standard Oil Co. of California El Segundo Modern Project 1 40CHTA-5 1,792 6,578 5,850

1968 Valley Plant Unit #3 1 75CHTA-4 6,200 6,050 5,900

1968 Kentucky Utilities Co. E.B. Brown Unit #3 2 65CHTA-4 4,310 8,789 5,920

1968 Standard Oil Co. of California El Segundo Modern Project 1 40CHTA-5 1,761 9,140 6,650

1968 Standard Oil Co. of California El Segundo Modern Project 1 40CHTA-5 1,761 9,140 6,650

1969 Carolina Power & Light Co. Asheville #2 Unit Project 2 50CHTA-7 1,515 5,200 3,580

1969 American Electric Power Corp John E. Amos Plant Unit 3 1 20x25CA-4 21,596 10,699 4,160

1969 Appalachian Electric Power John Amos Unit #3 1 20x25CA-4 21,596 10,699 4,160

1969 Indiana & Michigan Electric Gavin Unit #1 1 20x25CA-4 21,596 10,699 4,160

Page 8 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1969 Indiana & Michigan Electric Gavin Unit #2 1 20x25CA-4 21,596 10,699 4,160

1969 Tata EbascoDhuvaren Thermal Power

St. (India)4 40CHTA-6 1,339 5,541 4,775

1969 Tata EbascoDhuvaren Thermal Power

St. (India)2 50CHTA-6 1,339 5,541 4,775

1969 American Electric Power CorpJohn E. Amos Plant Unit 1

& 22 130CHTA-4 12,548 11,300 4,840

1970 Long Island Lighting Co. North Point Unit #3 1 100CHTA-6 6,287 7,300 3,500

1970 Virginia Electric & Power Co. Storm Power Station #3 1 100CHTA-6 5,068 7,460 3,500

1970 Virginia Electric & Power Co. Storm Power Station #2 2 100CHTA-6 5,160 7,395 3,550

1970 Iberduero Santurce Plant #2 1 65CHTA-7 2,642 7,500 4,236

1970 Delmarva P&L Co.Vienna Power Station Unit

#82 40CHTA-5 1,321 5,630 5,200

1970 Iberduero Santurce Plant #2 2 75CHTA-5 4,575 7,500 5,250

1970 Louisiana Power & Light Ninemile Pt #5 2 80CHTA-6 6,569 11,200 5,600

Page 9 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1970 New England Power Salem Harbor Station Unit 4 1 80CHTA-3 7,181 5,390 5,660

1970 New England Power Brayton Point Station Unit 4 1 80CHTA-3 7,181 5,390 5,660

1970 Detroit Edison Co. Monroe Unit #3 2 80CHTA-6 6,261 12,500 5,800

1970 Detroit Edison Co. Monroe Unit #4 2 80CHTA-6 6,261 12,500 5,800

1970 Initec / Iberduero Santurce 2 542 2 75CHTA-5 4,570 7,635 5,250 Turbine driven

1970 Initec / Iberduero Santurce 2 542 1 65CHTA-7 2,783 7,743 4,250 Motor driven

1971 Virginia Electric & Power Co.Yorktown Power Station

Unit #31 130CHTA-5 13,099 7,520 3,500

1971 Virginia Electric & Power Co.Yorktown Power Station

Unit #31 100CHTA-6 5,500 7,550 3,500

1971 Sevillana de Electricidad Bahia de Algeciras ll 1 50CHTA-6 2,400 6,047 4,625

1971 Duke Power CompanyBelews Creek Station #1 &

#22 95CHTA-5 9,000 11,000 5,350

1971 Duke Power CompanyBelews Creek Station #1 &

#22 95CHTA-5 9,000 11,000 5,350

Page 10 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1971 Salt River Project Navejo Unit #1 2 80CHTA-6 6,900 10,525 5,550

1971 Salt River Project Navejo Unit #2 2 80CHTA-6 6,900 10,525 5,550

1971 Salt River Project Navejo Unit #3 2 80CHTA-6 6,900 10,525 5,550

1971 Bowlie Point Plant Unit #2 2 75CHTA-5 5,500 7,149 5,670

1971 Carolina Power & Light Co. Roxboro Station #3 2 80CHTA-4 6,701 7,871 5,750

1971Con Edison Co. of New York

Inc.Astoria Genration Station

Unit #62 80CHTA-4 7,947 7,021 5,825

1971 Mid ValleySabine Power Station Unit

#41 65CHTA-4 3,298 8,625 5,890

1971Public Service of New

HampshireNewington Station Unit #1 1 80CHTA-3 6,974 5,669 5,900

1971Initec / Sevillana de

ElectricidadBahía de Algeciras 2 533 2 65CHTA-4 4,447 7,379 5,800 Turbine driven

1971Initec / Sevillana de

ElectricidadBahía de Algeciras 2 533 1 50CHTA-6 2,400 6,217 4,625 Motor driven

1972 United Illuminating Co. Coke Works Unit 1 1 65CHTA-8 1,999 6,400 3,580

Page 11 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1972 Taunton Municipal Lighting Plant Unit 2-4 Element 2 40CHTA-6 1,299 5,200 4,685

1972 Boston Edison Mystic Unit #7 1 65CHTA-4 2,985 6,391 5,150

1972 Pennsylvania Power Co.Bruce Mansfield Plant Unit

#12 95CHTA-5 7,899 11,450 5,225

1972 Pennsylvania Power Co.Bruce Mansfield Plant Unit

#22 95CHTA-5 7,899 11,450 5,225

1972 Boston Edison Mystic Unit #7 1 95CHTA-4 10,241 7,694 5,325

1972 United Illuminating Co. Coke Works Unit 1 1 95CHTA-3 8,330 7,598 5,500

1972Bechtel / Union Electric

CompanyRush Island Plant Unit #1 2 75CHTA-5 5,500 7,201 5,600

1972Bechtel / Union Electric

CompanyRush Island Plant Unit #2 2 75CHTA-5 5,500 7,201 5,600

1972 Sevillana de Electricidad Bahia de Algeciras ll 2 65CHTA-4 4,451 6,946 5,750

1972 IR Austrailia Ltd. 6 40CHTA-5 1,633 6,814 5,785

1972Wisconsin Power & Light

CompanyColombia Generation

Station Unit #12 75CHTA-4 5,336 7,671 5,990

Page 12 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1973 Virgina Electric & Power Co.Possum Pt Power Station

Unit #51 130CHTA-5 13,099 7,520 3,500

1973 Virginia Electric & Power Co.Possum Pt Power Station

Unit #51 100CHTA-6 5,500 7,549 3,500

1973 Appalachian Electric Power Graham Station 1 20x25CA-4 21,596 10,699 4,160

1973 Buckeye Power Inc. Cardinal Plant Unit #3 1 130CHTA-4 10,897 11,900 4,850

1973 Tokyo Electric Power Sodegavra #3 2 95CHTA-5 8,418 10,968 5,250

1973 Florida Power & Light Co. Port Manatee Unit #1 2 80CHTA-4 6,798 7,385 5,625

1973 Florida Power & Light Co. Port Manatee Unit #2 2 80CHTA-4 6,798 7,385 5,625

1973 Carolina Power & Light Co. Roxboro Station #4 2 80CHTA-4 6,701 7,871 5,750

1973 Cincinnati Gas & Electric Miami Fort Station Unit #7 2 65CHTA-4 4,561 7,651 5,975

1974 Long Island Lighting Co. North Port Unit #4 1 100CHTA-6 6,287 7,300 3,500

1974 Kansas Power & LightJeffrey Energy Center Unit

#12 10x16CA-5 5,878 6,558 5,100

Page 13 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1974 Kansas Power & LightJeffrey Energy Center Unit

#22 10x16CA-5 5,878 6,558 5,100

1974 IR Australia Ltd.Electric Company South

Wales4 75CHTA-5 4,993 6,726 5,182

1972 IR Austrailia Ltd.Electric Company South

Wales2 40CHTA-5 1,409 6,322 5,530

1974 Florida Power & Light Co. Martin County Unit #1 2 80CHTA-4 6,798 7,385 5,625

1974 Florida Power & Light Co. Martin County Unit #2 2 80CHTA-4 6,798 7,385 5,625

1975 Indiana & Michigan Electric Rockport Plant #1 1 20x25CA-4 21,596 10,699 4,160

1975 Indiana & Michigan Electric Rockport Plant #2 1 20x25CA-4 21,596 10,699 4,160

1975 Pennsylvania Power Co.Bruce Mansfield Plant Unit

#32 95CHTA-5 7,899 7,201 5,225

1976 Basin Electric Power Larimie Unit #1 & #2 2 75CHTA-10 2,849 7,201 3,580

1976 Basin Electric Power Larimie Unit #1 & #2 4 75CHTA-5 5,077 7,861 5,600

1976 IR Austrailia Ltd. 6 65CHTA-4 3,012 7,480 5,853

Page 14 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1977 Appalachian Electric Power Mountaineer Plant 1 20x25CA-4 21,596 10,699 4,160

1977 Texas Municipal Gibbons Creek Station 2 65CHTA-5 3,967 6,926 5,250

1977 Initec / Eneco Puente Nuevo 3 313 3 6x13 CA-4 3,139 656 5,980 Motor driven

1978 Oklahoma Gas & Electric Muskogee Unit #6 2 75CHTA-5 4,764 7,516 5,400

1979 Central Louisiana Electric Co.Rodemacher Power Station

Unit #31 85CHTA-8 3,998 6,601 3,452

1979 Basin Electric Power Larimie Unit #3 1 75CHTA-10 2,849 7,201 3,580

1979 Central Louisiana Electric Co.Rodemacher Power Station

Unit #21 95CHTA-4 9,023 7,356 5,020

1979 Basin Electric Power Larimie Unit #3 2 75CHTA-5 5,077 7,861 5,600

1979 IR Australia Ltd. 1 65CHTA-4 3,927 7,694 5,750

1979 City of LakelandMcIntosh Power Plant Unit

#31 75CHTA-5 6,230 7,300 5,800

1979 Bechtel/Gulf States UtilitiesRoy S. Nelson Station Unit

#62 75CHTA-4 5,310 7,136 5,850

Page 15 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1979 Houston Light & Power Parrish Unit #7 2 75CHTA-4 5,310 7,136 5,850

1980Plains Electric Generation And

Trans.Plains Escalante Unit #1 1 65CHTA-3 2,276 5,066 4,920

1980 Kansas Power & LightJeffrey Energy Center Unit

#32 10x16CA-5 6,160 6,558 5,720

1980Plains Electric Generation And

Trans.Plains Escalante Unit #1 1 65CHTA-3 3,998 5,929 5,720

1980 NIPSCO Schafer Station #17 3 65CHTA-5 3,615 7,530 5,900

1981 Deseret Generation & Trans.Moonlight Generation

Station1 50CHTA-8 1,400 6,322 3,580

1981 Initec/Endesa Almería 1 550 2 65CHTA-4 5,292 8,143 5,995 Turbine driven

1981 Initec/Endesa Almería 1 550 1 6x13 CA-5 2,862 8,179 5,375 Motor driven

1981 Endesa Almeria ll 2 65CHTA-4 4,324 6,732 5,300

1981BBC - Switzerland / U.

ElectricaNarcea 3 350 1 75CHTA-5 5,292 8,471 5,485 Turbine driven

1981BBC - Switzerland / U.

ElectricaNarcea 3 350 2 6x13 CA-5 2,003 6,906 4,700 Motor driven

Page 16 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1981Siemens KWU - Germany/U.

ElectricaLa Robla 2 350 1 75CHTA-5 5,151 8,507 5,480 Turbine driven

1981Siemens KWU - Germany/U.

ElectricaLa Robla 2 350 2 6x13 CA-5 1,695 8,507 4,800 Motor driven

1981Initec / Hidroeléctrica del

CantábricoAboño 2 543 3 75CHTA-6 4,271 6,834 4,650 Motor driven

1981E. Agrupados / Hidroeléctrica

del CantábricoSoto Ribera 3 350 1 75CHTA-4 5,724 7,451 5,800 Turbine driven

1981E. Agrupados / Hidroeléctrica

del CantábricoSoto Ribera 3 350 2 6x13 CA-4 2,862 679 5,820 Motor driven

1981E. Agrupados / Sevillana de

ElectricidadLos Barrios 1 550 2 65CHTA-4 4,711 7,162 5,500 Turbine driven

1981E. Agrupados / Sevillana de

ElectricidadLos Barrios 1 550 1 6x13 CA-4 2,831 7,379 5,770 Motor driven

1981 Initec / Iberduero Velilla 2 350 1 80CHTA-5 6,530 7,014 4,950 Turbine driven

1981 Initec / Iberduero Velilla 2 350 2 6x13 CA-4 3,263 7,090 6,000 Motor driven

1982 Big River Electric Corp. D.B. Wilson Station #1 1 65CHTA-9 2,501 6,749 3,465

1982 Big River Electric Corp. D.B. Wilson Station #1 2 65CHTA-4 4,350 7,251 4,350

Page 17 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1982 Deseret Generation & Trans. Deseret Generation Station 2 80CHTA-4 7,582 7,418 5,800

1982 Terminor C.T. Velilla 1 80CHTA-5 5,680 6,391 4,550

1983 Pacific Gas & Electric Moss Landing #6 and #7 2 75CHTA-6 5,002 11,000 5,850

1984MAGUE / Brown Boveri -

Portugal / SwitzerlandSines 3 300 1 80CHTA-4 5,609 8,980 5,660 Turbine driven

1984MAGUE / Brown Boveri -

Portugal / SwitzerlandSines 3 300 2 6x13 CA-5 2,805 6,906 5,740 Motor driven

1984 Babcock & Wilcox - Canada Suralaya 3 400 3 65CHTA-5 3,500 7,707 4,925 Motor driven

1984 Babcock & Wilcox - Canada Suralaya 4 400 3 65CHTA-5 3,500 7,707 4,925 Motor driven

1984 Alberta Power 1 75CHTA-4 5,512 6,432 5,280

1984Mague / Brown Boveri and

CompanySines lll 1 80CHTA-4 5,583 7,621 5,582

1984 Orlando Utilities Comm. 1 65CHTA-4 3,324 6,650 5,850

1985 Salt River 2 65CHTA-5 3,826 7,510 5,150

Page 18 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1986MAGUE / Brown Boveri -

Portugal / SwitzerlandSines 3 300 1 80CHTA-4 5,609 8,980 5,660 Turbine driven

1986MAGUE / Brown Boveri -

Portugal / SwitzerlandSines 3 300 2 6x13 CA-5 2,805 6,906 5,740 Motor driven

1986Mague / Brown Boveri and

CompanySines IV 1 80CHTA-4 5,050 7,621 5,140

1988 Louisiana Power & Light Ninemile Point 1 65CHTA-5 3,698 8,947 6,150

1989 Westinghouse Electric - U.S.A. Old Dominion 1 350 3 65CHTA-4 DS 4,183 7,999 5,900 Motor driven

1989 Hamon Sobelco Paiton Power 6 65CHTA-5 3,425 7,795 5,000

1989 Westinghoust / Old Dominion Old Dominion #1 2 65CHTA-4 4,359 7,799 5,825

1989 Westinghouse / Old Dominion Old Dominion #1 1 65CHTA-4 2,237 7,001 5,900

1990 Cincinnati Gas & Electric Simmer 1 20x25CA-4 21,596 10,699 4,160

1990 Westinghouse / Old Dominion Old Dominion #2 2 65CHTA-4 4,359 7,799 5,825

1990 Westinghouse / Old Dominion Old Dominion #2 1 65CHTA-4 2,237 7,001 5,900

Page 19 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1990 Hamon Sobelco - Belgium Paiton 1 400 3 65CHTA-5 3,465 7,743 5,000 Motor driven

1990 Hamon Sobelco - Belgium Paiton 2 400 3 65CHTA-5 3,465 7,743 5,000 Motor driven

1991 Philadelphia Electric Eddystone #1 2 65CHTA-4 3,012 2,834 3,580

1991 Bechtel Carney's Point 3 75CHTA-9 2,809 6,512 3,580

1991 Ultrasystems Roanoke Valley 3 65CHTA-10 1,576 7,169 3,580

1991 Northwest Utlities Middletown No. 3 1 65CHTA-9 1,999 7,251 3,580

1991 Taiwan Power Co. Talin No. 6 1 65CHTA-9 2,426 7,362 3,580

1991 Taiwan Power Co. Talin No. 6 2 75CHTA-4 4,517 6,870 5,300

1991 Philadelphia Electric Eddystone #2 2 65CHTA-4 3,003 5,712 4,700

1991 Westinghouse Electric - U.S.A. Old Dominion 2 350 3 65CHTA-4 DS 4,183 7,999 5,900 Motor driven

1991 Mecánica de la Peña - Spain Carbon II 3 350 3 65CHTA-6 3,003 7,743 5,480 Motor driven

Page 20 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1991 Mecánica de la Peña - Spain Carbon II 4 350 3 65CHTA-6 3,003 7,743 5,480 Motor driven

1992 S&L/EGAT Khanom 1 x 660 3 65CHTA-8 1,964 4,501 2,985 Motor driven

1992 Philadelphia Electric Eddystone #1 2 65CHTA-4 3,012 2,244 3,580

1992 Philadelphia Electric Eddystone #2 2 12x18 CA 3,100 6,572 3,580

1992 Bechtel Keystone Project 2 x 140 3 65CHTA-11 1,942 7,021 3,580 Motor driven

1992 Philadelphia Electric Eddystone #2 2 65CHTA-4 2,999 5,712 4,700

1992 Philadelphia Electric Eddystone #1 2 65CHTA-4 2,902 7,011 5,180

1992 KEPCO Taean #1 & #2 4 75CHTA-6 4,800 11,000 5,800 Turbine driven

1992 Initec / Unelco Granadilla 1 80 2 65CHTA-11 1,387 6,726 3,525 Motor driven

1992 Initec / Unelco Granadilla 2 80 2 65CHTA-11 1,387 6,726 3,525 Motor driven

1993 Bechtel Indiantown 2 75CHTA-11 3,201 7,165 3,580

Page 21 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1993 Bechtel / Clover County Clover County 2 65CHTA-11 1,933 7,549 3,580 Motor driven

1993 Bechtel / US Generation Northampton County 2 x 140 2 65CHTA-11 1,933 7,549 3,580 Motor driven

1993 Initec / Unelco Tirajana 1 80 2 65CHTA-11 1,387 6,726 3,525 Motor driven

1993 Initec / Unelco Tirajana 2 80 2 65CHTA-11 1,387 6,726 3,525 Motor driven

1993SIEMENS KWU - Germany /

ElcogasPuertollano IGCC 320 2 65CHTA-11 1,915 6,362 2,915 Motor driven

1993Sargent & Lundy - U.S.A. /

EGATKhanom 600 3 65CHTA-8 1,999 4,364 2,970 Motor driven

1994 Southern California Edison Huntington Beach 1 & 2 4 65CHTA-8 2,017 6,400 3,480 FG

1994 Initec / Gesa Alcudia 3 130 3 65CHTA-11 DS 1,325 7,270 3,600 Motor driven

1994 Initec / Gesa Alcudia 4 130 3 65CHTA-11 DS 1,325 7,270 3,600 Motor driven

1995 Eneco Puente Nuevo 3 313 1 75CHTA-4 4,676 6,906 5,100 Motor driven

1995Westinghouse Electric - U.S.A.

/ Jiangsu Electric PowerYangzhou 1 600 2 75CHTA-4 5,781 9,196 5,600 Turbine driven

Page 22 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1995Westinghouse Electric - U.S.A.

/ Jiangsu Electric PowerYangzhou 1 600 1 65CHTA-4 3,470 9,488 5,900 Motor driven

1995Westinghouse Electric - U.S.A.

/ Jiangsu Electric PowerYangzhou 2 600 2 75CHTA-4 5,781 9,196 5,600 Turbine driven

1995Westinghouse Electric - U.S.A.

/ Jiangsu Electric PowerYangzhou 2 600 1 65CHTA-4 3,470 9,488 5,900 Motor driven

1996 Hitachi / Tuas Tuas 2x600 4 6x14CSB-4 5,700 Motor - Gear

Driven

1996 Hitachi / Tuas Tuas 2x600 4 75CHTA-5 5,300 Turbine driven

1996 Westinghouse / Dandong 2x350 4 6x14CSB-4 3,302 7,031 5,680 Turbine driven

1996 Westinghouse / Dandong 2x350 4 4x12CSB-6 1,982 7,126 5,150 Motor - Gear

Driven

1996 Westinghouse / Dalian 2x350 4 6x14CSB-4 3,302 7,031 5,680 Turbine driven

1996 Westinghouse / Dalian 2x350 4 4x12CSB-6 1,982 7,126 5,150 Motor - Gear

Driven

1996Raytheon / Jindal Tractebel

PowerToranagallu 130 6 3x10CSB-7 1,100 5,568 5,613

Motor - Gear Driven

1997 Black & Veatch / PLN Paiton 2 660 4 75CHTA-4 3,465 7,591 5,750 Turbine driven

Page 23 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1997 Black & Veatch / PLN Paiton 2 660 2 6x14CSB-5 4,187 7,315 5,600 Motor - Gear

Driven

1997 Raytheon / Zhuai Zhuai Power Station 700 4 75CHTA-4 6,758 6,938 5,200 Turbine driven

1997 Raytheon / Zhuai Zhuai Power Station 700 4 6x14CSB-4 3,070 6,152 5,250 Motor - Hydraulic Coupling Driven

1998Duke/Fluor Daniel / Occidental

ChemicalIngleside Cogen 600 4 6x14CSB-9 2,267 5,471 3,580 Turbine driven

1998 Formosa Petrochemical 600 2 75CHTA-6 5,100 12,179 5,650 Turbine driven

1998 Formosa Petrochemical 600 1 6x14CSB-6 2,910 12,327 6,050 Motor - Hydraulic Coupling Driven

1998 Mai Lao Power Corporation Mai Lao 600 2 75CHTA-6 5,100 12,178 5,650 Turbine driven

1998 Mai Lao Power Corporation Mai Lao 600 1 6x14CSB-6 2,910 12,327 6,050 Motor - Hydraulic Coupling Driven

1998 ABB / Morocco Jorf Lasfar 2x300 6 4x12CSB-4 2,422 6,706 6,300 Motor - Hydraulic Coupling Driven

1998 Duke / Fluor Daniel Hidalgo 500 2 4x12CSB-8/9 810 5,185 3,580 Motor driven

1998 Duke / Fluor Daniel Maine Independence 500 2 4x12CSB-8/9 810 5,185 3,580 Motor driven

Page 24 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

1998Siemens KWU - Germany / Scottish Hydro-Electric Plc

Peterhead Repowering Project

792 3 6x14CSB-6 2,734 6,506 4,450 Motor Driven

1999Duke/Fluor Daniel / Panda

EnergyErcot 2 5 4x12CSB-10 1,462 5,273 3,580 Motor driven

1999Duke/Fluor Daniel / Panda

EnergyErcot 1 5 4x12CSB-10 1,462 5,273 3,580 Motor driven

1999 Formosa Petrochemical Corp Mai Liao 600 4 75CHTA-6 5,099 11,923 5,650 Turbine Driven

1999 Formosa Petrochemical Corp Mai Liao 600 2 6x14CSB-6 2,910 11,887 6,050 Motor Driven

1999 Babcock Wilcox Espanola Meliti Achlada 3 65CHTA-8 3,166 9,252 4,770

1999 Babcock Wilcox - Spain / PPC Florina Power Station 3 65CHTA-8 3,166 3,527 4,771 Motor Driven

2000 Raytheon / Sithe Mystic Unit #7 1500 6 6x14CSB-9 1,603 7,004 3,580 Motor driven

2000 Duke Fluor Daniel - U.S.A. Bastrop 4 6x14CSB-8 1,413 515 3,580

2001 Hua Yang Elec. Co.Zhanghou Housi Power

Plant600 4 75CHTA-4 5,253 1,109 5,650 Motor Driven

2001 Hua Yang Elec. Co.Zhanghou Housi Power

Plant600 2 6x14CSB-6 2,924 1,211 6,050 Motor Driven

Page 25 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

2001General Electric / Dominion

Energy Possum Point CCP 4 6x14CSB-9 1,783 561 3,445 Motor Driven

2001General Electric / Dominion

Energy Dresden CCP 4 6x14CSB-9 1,783 561 3,445 Motor Driven

2001Duke Fluor Daniel - U.S.A. /

Reliant EnergySeward 2 75CHTA-4 4,451 597 5,540 Motor Driven

2002AELSA / Comisión Federal

ElectricidadEl Sauz 4 4x12CSB-12 1,096 4,890 3,580 Motor Driven

2003 Santee Cooper Cross Generating Station 600 2 80CHTA-6 5,301 7,710 4,750 Motor Driven

2004Black & Veatch / Wisconsin

Public Service Corp.Weston 4 500 3 65CHTA-6 4,403 11,975 5,800 Motor Driven

2004 Nevada Power Company Reid Gardner 300 3 65CHTA-10 2,642 7,612 3,570 Motor Driven

2004Foster Wheeler Italiana / SET

S.r.l.Teverola 400 2 6x14CSB-8 2,025 6,391 3,580 Motor Driven

2004 Siemens PG / CS Energy Kogan Creek 750 2 80CHTA-6 6,177 11,417 5,644Motor - Fluid

Coupling Driven

2004General Electric / Widows

Creek Unit 7TVA-Widows Creek 7 2 10 CHTA-3 4,002 7,500 6,600 Turbine Driven

2005 Santee Cooper Cross GS Unit 4 600 2 80CHTA-6 5,292 7,710 4,750 Turbine Driven

Page 26 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

2005 Fluor Enterprises Newmont TS-Power Plant 200 3 6x14 CSB-10 1,748 7,001 3,490Motor - Fluid

Coupling Driven

2005Bechtel Power Corp. /

Wisconsin Electric Power Co Inc

Elm Road Generating Station

600 4 75CHTA-6 5,169 10,988 5,873 Turbine driven

2005Nebraska City Power Partners / Omaha Public Power District

Nebraska City Station Unit 2

660 2 75CHTA-4 5,733 6,775 5,520Motor - Fluid

Coupling Driven

2006Calpine Corporation / Calpine

Greenfield LTDGreenfield 280 3 65CHTA-8 1,959 6,378 3,493

Motor - Fluid Coupling Driven

2006Shaw Stone & Webster /

CLECO Power LLCRodemacher #3 660 1 95CHTA-4 10,127 7,218 4,970 Turbine driven

2006Shaw Stone & Webster /

CLECO Power LLCRodemacher #3 660 1 75CHTA-4 5,081 5,217 5,650

Motor - Fluid Coupling Driven

2006Black & Veatch / Plum Point

Power PartnersPlum Point 600 2 75CHTA-4 5,922 6,988 5,660

Motor - Fluid Coupling Driven

2006 SRP / Salt River Project Springerville 4 300 3 65CHTA-4 3,809 6,923 5,570Motor - Fluid

Coupling Driven

2006Fluor Enterprises Inc. / Oak

Grove SesOak Grove 870 2 80CHTA-6 7,142 12,598 5,930 Turbine driven

2007 Worley Parsons PeeDee 600 2 80CHTA-6 5,440 10,630 5,500 Turbine driven

2007 Worley Parsons PeeDee 600 1 4x12CSB-12 1,200 6,400 3,580 Motor driven

Page 27 of 28 Print date : 3/25/2008

FLOWSERVE CORPORATION

HORIZONTAL MULTISTAGE BARREL PUMPSRadially Split Design

Plant Size Flow TDH

Year Customer/Location Name MW Qty Pump (gpm) (feet) RPM Driver

POWER Generation and Desalination FLT

2007 Stone & Webster AEP / Turk 600 1 130CHTA-5 9,973 11,197 4,605 Turbine driven

2007 City Utilities Springfield 300 2 6x14CSB-9 2,560 7,185 3,480Motor - Fluid

Coupling Driven

2007 Stone & Webster Cliffside 800 2 95CHTA-6 7,200 11,675 4,760 Turbine driven

2008Shaw Stone & Webster /

DominionVirginia City Hybrid Energy

Center585 3 80CHTA-5 5,170 7,260 4,850

Motor - Fluid Coupling Driven

Total sold to date : 607

Page 28 of 28 Print date : 3/25/2008

VINTAGE PARTS MARKETING PRODUCT LINE: CHTA - CA HERITAGE COMPANY: IR CONFIGURATION: Barrel - diffuser TYPICAL APPLICATION: Boiler Feed Pump VINTAGE: 1959 - current PRODUCT LIFESPAN: Undefined SUBJECT: Material Codes The CA developed into the CHTA as the product line expanded. This product is still sold today. The CHTB and CHTC manufactured by KSB are very similar, since KSB licensed this product. NOTE: This information is intended for the use of Flowserve Employees. The information provided is based on standard catalogue / price book information. Details for specific units or serial numbers may be different as a result of non-standard construction, and parts, repairs and upgrades provided by Flowserve or third parties.

3 IMPELLER 805 (1) (2) 12% Chrome ASTM A487 Gr CA-6NM (BHN - 248)

6 CASING RING 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

8 SHAFT SLEEVE (Labyrinth seals only) 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

10 SHAFT 1056 12% Chrome Bar ASTM A276 Type 410 Cond.T

56 DIFFUSOR 805 12% Chrome ASTM A487 Gr CA-6NM

59 BALANCING SLEEVE 829X400 Forged 12% Chrome ASTM A743Type 416 HT (BHN - 352/444)

60 CHANNEL RING 805 12% Chrome ASTM A487 Gr CA-6NM

61 BALANCING DRUM 829X300 Forged 12% Chrome ASTM A743 Type 416 HT (BHN - 262/302)

88 LABYRINTH SEAL (Not used with Mech. Seal) 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

109 RING - RETAINING (Drum) 65H 12% Chrome AISI 410 HT

127 SHAFT SLEEVE NUT (Labyrinth seals only) 20H 13% Chrome AISI Type 416 HT

138 BEARING LINING 142 Tin-Base Babbitt ASTM B23 Alloy Grade No. 2BEARING LINING BACKING 17 Carbon Steel ASTM A29

178 MAIN PRESSURE BOLTING 314 4140 HT ASTM A193 Gr. B7

179 MAIN PRESSURE NUTS 377 Carbon Steel ASTM A194 Gr. 2H

199/200 BEARING HOUSING (Body & Cap) 102 Carbon Steel ASTM A216 Gr. WCB

252 RING - SPLIT (Drum) 65H 12% Chrome AISI 410 HT

257 SHIM 669 Austenitic SS AISI Type 304 SS

264 STUFFING BOX EXTENSION 534 Forged 1 1/4 Chrome ASTM A336 Class F11

269 SUCTION RING NA/805 (4) 12% Chrome ASTM A240 Type 410/ASTM A487 Gr CA-6NM

294 SLEEVE- LABYRINTH (At Bearings) 641 Aluminum Alloy ASTM B308 Gr 6061 T6

357 CHANNEL RING BUSHING 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

359 BARREL 534 Forged 1 1/4 Chrome ASTM A336 Class F11BEARING BRACKET 240/102 (4) Carbon Steel ASTM A36/ASTM A216 Gr. WCBBARREL FEET 240 Carbon Steel ASTM A36

361 DISCHARGE HEAD 534 Forged 1 1/4 Chrome ASTM A336 F11

363EGASKET DISCHARGE HEAD TO BARREL S-316-9 316L SS Flexitallic/S-316-9

438 WARMUP ORIFICE - MULTI-PLATE SHELL 755L 304L S.S. Pipe ASTM A312 Type 304L PLATES & SPACERS 407L 304L SS Bar ASTM A 276 Type 304L Cond. A

453 DISCHARGE NOZZLE 534 Forged 1 1/4 Chrome ASTM A336 F11

454 SUCTION NOZZLE 580 1 1/4 Chrome ASTM A217 Gr. WC6

GLANDS STUDS 314 4140 HT ASTM A193 Gr. B7

GLAND NUTS 377 Carbon Steel ASTM A194 Gr. 2H

NOTES: (1) IR HERITAGE MATERIAL 638 (ASTM A217 Grade CA-15) MAY BE PROVIDED AT FLOWSERVE OPTION. (2) TYPICALLY IMPELLERS ARE RINGLESS. IF IMPELLERS WITH WEAR RINGS ARE PROVIDED THE RING MATERIALS ARE:

4 RING - IMPELLER 20H 13% Chrome AISI Type 416 HT (BHN - 262/302)5 BUSHING RING - IMPELLER 20H 13% Chrome AISI Type 416 HT (BHN - 262/302)

(3) ASTM EQUIVALENT FOR CHEMICAL AND MECHANICAL PROPERTIES. FLOWSERVE CROSS-REFERENCES ASTM AND FLOWSERVE MATERIAL FOR CONVIENCE IN SELECTION WORK; THERE ARE DEVIATIONS BETWEEN THE FLOWSERVE STANDARD MATERIALS AND THE ASTM REQUIREMENTS. IN MOST CASES, THESE ARE UPGRADES, HOWEVER ALL DEVIATIONS MUST BE NOTED IN OUR PROPOSAL. (4) FLOWSERVE OPTIONMaterials for Boiler Feed Service Rev I.xls

Materials for Boiler Feed Service - Model CHTA, CA, & CSB1.25% Chrome Barrel

SIMILAR INDUSTRIAL DESIGNATION (3)GENERIC

DESCRIPTIONPART NAME

PART NO.

FLOWSERVE MATERIAL (IR

HERITAGE)

3 IMPELLER 805 (1) (2) 12% Chrome ASTM A487 Gr CA-6NM (BHN - 248)

6 CASING RING 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

8 SHAFT SLEEVE (Labyrinth seals only) 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

10 SHAFT 1056 12% Chrome Bar ASTM A276 Type 410 Cond.T

56 DIFFUSOR 805 12% Chrome ASTM A487 Gr CA-6NM

59 BALANCING SLEEVE 829X400 Forged 12% Chrome ASTM A743Type 416 HT (BHN - 352/444)

60 CHANNEL RING 805 12% Chrome ASTM A487 Gr CA-6NM

61 BALANCING DRUM 829X300 Forged 12% Chrome ASTM A743 Type 416 HT (BHN - 262/302)

88 LABYRINTH SEAL (Not used with mech. Seal) 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

109 RING - RETAINING (Drum) 65H 12% Chrome AISI 410 HT

127 SHAFT SLEEVE NUT (Labyrinth seals only) 20H 13% Chrome AISI Type 416 HT

138 BEARING LINING 142 Tin-Base Babbitt ASTM B23 Alloy Grade No. 2BEARING LINING BACKING 17 Carbon Steel ASTM A29

178 MAIN PRESSURE BOLTING 314 4140 HT ASTM A193 Gr. B7

179 MAIN PRESSURE NUTS 377 Carbon Steel ASTM A194 Gr. 2H

199/200 BEARING HOUSING (Body & Cap) 102 Carbon Steel ASTM A216 Gr. WCB

252 RING - SPLIT (Drum) 65H 12% Chrome AISI 410 HT

257 SHIM 669 Austenitic SS AISI Type 304 SS

264 STUFFING BOX EXTENSION 534 Forged 1 1/4 Chrome ASTM A336 Class F11

269 SUCTION RING NA/805 (4) 12% Chrome ASTM A240 Type 410/ASTM A487 Gr CA-6NM

294 SLEEVE- LABYRINTH (At Bearings) 641 Aluminum Alloy ASTM B308 Gr 6061 T6

357 CHANNEL RING BUSHING 20K 13% Chrome AISI Type 416 HT (BHN - 353/415)

359 BARREL 556-2 Forged Carbon Steel ASTM A266 Class 2BARREL INLAY 309 SS 309 SSBEARING BRACKET 240/102 (4) Carbon Steel ASTM A36/ASTM A216 Gr. WCBBARREL FEET 240 Carbon Steel ASTM A36

361 DISCHARGE HEAD 556-2 Forged Carbon Steel ASTM A266 Class 2

363EGASKET DISCHARGE HEAD TO BARREL S-316-9 316L SS Flexitallic/S-316-9

438 WARMUP ORIFICE - MULTI-PLATE SHELL 755L 304L S.S. Pipe ASTM A312 Type 304L PLATES & SPACERS 407L 304L SS Bar ASTM A 276 Type 304L Cond. A

453 DISCHARGE NOZZLE 556-2 Forged Carbon Steel ASTM A266 Class 2

454 SUCTION NOZZLE 102 Carbon Steel A216 Gr. WCB

GLANDS STUDS 314 4140 HT ASTM A193 Gr. B7

GLAND NUTS 377 Carbon Steel ASTM A194 Gr. 2H

NOTES: (1) IR HERITAGE MATERIAL 638 (ASTM A217 Grade CA-15) MAY BE PROVIDED AT FLOWSERVE OPTION. (2) TYPICALLY IMPELLERS ARE RINGLESS. IF IMPELLERS WITH WEAR RINGS ARE PROVIDED THE RING MATERIALS ARE:

4 RING - IMPELLER 20H 13% Chrome AISI Type 416 HT (BHN - 262/302)5 BUSHING RING - IMPELLER 20H 13% Chrome AISI Type 416 HT (BHN - 262/302)

(3) ASTM EQUIVALENT FOR CHEMICAL AND MECHANICAL PROPERTIES. FLOWSERVE CROSS-REFERENCES ASTM AND FLOWSERVE MATERIAL FOR CONVIENCE IN SELECTION WORK; THERE ARE DEVIATIONS BETWEEN THE FLOWSERVE STANDARD MATERIALS AND THE ASTM REQUIREMENTS. IN MOST CASES, THESE ARE UPGRADES, HOWEVER ALL DEVIATIONS MUST BE NOTED IN OUR PROPOSAL. (4) FLOWSERVE OPTIONMaterials for Boiler Feed Service Rev I.xls

Materials for Boiler Feed Service - Model CHTA, CA, & CSBCarbon Steel Barrel w/Inlay

SIMILAR INDUSTRIAL DESIGNATION (3)GENERIC

DESCRIPTIONPART NAME

PART NO.

FLOWSERVE MATERIAL (IR

HERITAGE)