vertical load design
DESCRIPTION
vertical loadsTRANSCRIPT
Vertical - SummaryVertical Loading CalculationsComponentDead LoadExterior Roof Load at Prefabricated Trusses:Sheet Metal Roof System2.20Plywood Sheathing - 1/2"1.50Miscellaneous (Lighting, Mechanical, etc.)3.30Prefabricated Trusses:1.50Top Chord DL(2x6 Top Chords @ 24" O.C.)7.00(psf)(w/out Self Weight)R-19 Batt Insulation2.00Gyp Board Ceiling5.00Prefabricated Trusses:1.50(2x6 Bot Chords @ 24" O.C.)Bot Chord DLMiscellaneous (Lighting, Mechanical, etc.)3.0010.00(psf)(w/out Self Weight)Dead Load =20.00(psf)Live Load =20.00(psf)Exterior TrellisHSS 6 x 12 x 1/2"5.006x8 Joists @ 30" O.C.5.00Miscellaneous2Dead Load =12.00(psf)Live Load =20.00(psf)Interior Roof Load with Ceiling:Flooring4.202x8 Joist @16" O.C.2.00Plywood Sheathing - 1/2"1.50R-19 Batt Insulation2.00Gyp Board Ceiling5.00Miscellaneous (Lighting, Mechanical, etc.)5.30Dead Load =20.00(psf)Live Load =20.00(psf)Exterior Roof Load with Ceiling:Sheet Metal Roof System2.20Plywood Sheathing - 1/2"1.502x8 Joist @16" O.C.2.00R-19 Batt Insulation2.00Gyp Board Ceiling5.00Miscellaneous (Lighting, Mechanical, etc.)5.3Dead Load =18.00(psf)Live Load =20.00(psf)Wood Frame Walls:Stucco / Siding10.00Plywood Sheathing - 1/2"1.502x6 Studs @16" O.C.1.40R-19 Batt Insulation2.00Gyp Board5.00Misc3.10Dead Load =23.00(psf)Masonry Walls:6" Thick58.00(psf)8" Thick78.00(psf)12" Thick124.00(psf)