vasgamme hall
TRANSCRIPT
-
7/31/2019 Vasgamme Hall
1/12
Current & Voltage Transducer
Open Loop CT
Closed Loop CT & VT
Magnetic Components
1 / 12 Rev. No. 2.0 / 03.12.2008
-
7/31/2019 Vasgamme Hall
2/12
Technical Information
A Current Transducer is a device for measuring AC and DC currents based on the Hall-Effect technology.
The general functionality is described in the following diagram:
Figure 1: General concept of the Current Transducer function
BFi OPTiLAS provides Current Transducer using the following two technologies:
1) Open Loop Technology: 2) Closed Loop Technology:
Figure 2: Functional diagramm of the Open Loop Technology
Advantages: Advantages:
A current carrying conductor positioned through theaperture of the sensor creates a magnetic field that is
proportionate to the current.This field is concentrated by the core and sensed by
the Hall Effect element that is mounted in the air gap
of the core.The Hall generator is connected to the input of theamplifier who amplified the voltage.
The output is an output voltage.
- Very good accuracy and linearity
- Wide bandwidth
- Low gain drift
BFi OPTiLAS A well known partner for customized Chokes and Transformers who has an excellent reputationfor high quality & customer orientated support.Starting from simple Current Transformer designs and due to growing demand, we are now able to offeradvanced current and voltage measurement like complex signal shapes and high frequencies with high accuracy.We offer support in nearly all markets of Industrial, Automotive, Automation and Renewable Energies.To date, we are proud to provide you with more than 70 various designs.
Figure 3: Functional diagramm of the Open Loop Technology
- Smaller construction (size)
Open Loop Transducers use the simplestimplementation of the Hall-Effect.
Closed Loop Transducers have a compensationcircuit that improves the performance.
- Low power consumption
The Advantages are giving the best solution for costeffective current measurement!
The primary current lp produces a magnetic flux.
This magnetic flux is aligned by a complementary
flux produced by driving a current through thesecondary windings.
A hall device and associated electronic circuitgenerate the compensating current that is used for theoutput.
The conversion of the output current to an output
voltage is easily done by adding a measurementresistor, RM, in series with the secondary coil.
- Light in weight
The Advantages are giving the best solution foraccurate current measurement!
- Fast response time
Primary Current
IpConversion
B to UH
Intermediate:
Flux Density
B
Intermediate: Hall
Voltage
UH
Output
Voltage/Current
Vout / IoutConversion
Ip to B
Conversion
UH to Vout / Iout
1
Input - Current
Carrying Conductor
Softmagnetic Core Hall-Effect Sensor Electronic Circuit & Output
Magnetic Components
2 / 12 Rev. No. 2.0 / 03.12.2008
-
7/31/2019 Vasgamme Hall
3/12
Overview - Current & Voltage Transducer
Current TransducerClosed Loop
Primary
nominal
r.m.s current
IPN [A]
PCB - PCB Through Hole -
PCB
Through Hole -
Connector
< 100 X X X
100 ... < 500 X X X
500 X
Open Loop
Primary
nominal
r.m.s current
IPN [A]
PCB - PCB Through Hole -
PCB
Through Hole -
Connector
< 100 X X
100 ... < 500 X
500 X
Voltage TransducerClosed Loop
Primarynominal
r.m.s current
IPN [A]
PCB - PCB Through Hole -
PCB
Through Hole -
Connector
< 100 X
100 ... < 500
500
Magnetic Components
1) Customer Solutions are possible 3 / 12 Rev. No. 2.0 / 03.12.2008
-
7/31/2019 Vasgamme Hall
4/12
Current Transducer - Closed Loop
Picture Type Primary
nominal
r.m.s
current
IPN [A]
Primary current,
measuring
range
IP,range [A]
Supply
voltage
@
IPN,
VC [V]
Secondary
nominal
r.m.s
current
ISN [mA]
Mechanical
dimensions
(L x W x H)
[mm]
Window
size
[mm]
PCB - PCBG00K25B00A01 25/12/8/6/5 0...36/18/12/9/7 15 25 26 x 15 x 30 -
G00K25B00A02 25 0 ... 50 12...15 25 33.3 x 12.5 x 20.5 -
G00K25B00A10 25 / 12 / 8 0... 55 / 27 / 18 12...15 25 33.3 x 15 x 21 -
Through Hole - PCBG00K25B02A07 25 0 ... 50 12...15 25 36 x 14,5 x 32,5 15 x 10,4
G00K50B02A01 50 0 ... 80 12...15 50 36 x 14,5 x 32,5 15 x 10,4
G00K50B02A02 50 0 ... 100 12...15 25 36 x 14,5 x 32,5 15 x 10,4
G00K25B04A01 25 0 ... 50 12...15 25 33 x 14,5 x 25 7,6
G00K50B04A01 50 0 ... 80 12...15 50 33 x 14,5 x 25 7,6
Through Hole - ConnectorG00K50B12A01 50 0 ... 100 12...15 50 51,4 x 33,5 x 57,9
G00K50B16A01 50 0 ... 100 12...15 50 48,8 x 26 x 51,63 15,5 x 15,5