Use of microscopesprepared by

Jennifer GoseDDDI Project Coordinator

Consortium for Internet Imaging and Database SystemsCollege of Agricultural and Environmental Sciences

The University of Georgia

Page 2: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Using microscopes to capture images for diagnosing agricultural problems requires:

- appropriate specimen preparation

- proper microscope setup

- correct use of microscopes

- proper camera use

Specimen preparation is a very important aspect of capturing microscope images, and varies greatly with subjects. Although specific microscopes vary in features and operation, principles of setup and manipulation are usually similar. Video cameras require a different approach to image capture than hand-held still-picture cameras, but again, principles of using cameras are similar.

Page 3: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Setting up a trinocular dissectingmicroscope for best viewing

Page 4: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Ocular tube for mounting a camera

Oculars for viewing by eye

“Trinocular” means three oculars or eyepieces

Page 5: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Two independent lens systems

A stereo “dissecting” scope has two complete lens systems, producing two separate images which are combined in the mind of the observer to produce a three-dimensional image that allows

easier manipulation of specimens.

Page 6: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Upper illuminator for “incident light” viewing

Lower illuminator for “transmitted light” viewing

Specimens can be illuminated from two light sources; one below and one above, depending on needs of viewing a

particular specimen

Page 7: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Dimmer switch for lights

Light source selection switch

Illuminating specimens from below provides for “transmitted” light viewing and from above for “incident” light viewing. One control switch selects the light source and the other varies light intensity. To preserve bulb life, IT IS IMPORTANT

to reduce current surge by turning the dimmer all the way down before operating the light-selection switch.

Page 8: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Magnification zoom-control

Focus control

Focus and magnification can be varied to produce the best view of a specimen

Page 9: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Light-colored stage for dark specimens and dark-colored stage for light ones

Specimens for incident-light viewing can be placed against various backgrounds to improve contrast and feature

identification

Page 10: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

As with any images used for diagnoses, relative size is extremely important.

Whenever possible, a comparative scale should be included with an image, or at least the approximate magnification indicated.

cm.

approx. 100X

Page 11: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

To send an image from the dissecting scope to the ocular tube for mounting a camera, a diverter prism is moved out of the field of view on one lens system. This process eliminates the image from one of the viewing eyepieces, and may require repositioning the specimen for best viewing.

For viewing through eyepiece

For capturing with camera

Page 12: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

A stereo dissecting microscope is normally used to view relatively large specimens at

magnifications from about 5X to about 50X.

The scope provides a very large range of adjustment to accommodate a variety of

specimen sizes and to allow many options for specimen illumination.

Page 13: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

To accommodate large specimens, the entire focusing head of the scope can be raised on the support column.

Small specimens can be accommodated by lowering the focusing head on the support column. The illuminator can be

moved to provide light as needed for best viewing.

Support column

Focusing head

Page 14: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Adjust the microscope eyepieces so you can comfortably see a well-focused image through both.

Space eyepieces so you can comfortably see through both at the same time.If one eyepiece tube is fixed focus, close the opposite eye and, using the microscope focusing knob, carefully focus an image of the sample for the open eye. (If both eyepiece tubes are variable focus, either one will do.) Now close the other eye and use the variable focus eyepiece tube to bring the image into focus for the open eye.

Page 15: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Focus on the specimen at the lowest Zoom setting and be sure the feature of interest is in the center of the field of view. There will be a much larger field of view but much less detail

visible than at higher Zoom settings.

Page 16: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Zoom to the desired magnification level and refocus if necessary. The field of view will be much reduced, but the

feature of interest will be much magnified.

Page 17: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

When the microscope has been adjusted to produce the best image of a specimen, it is

ready for capturing with the camera. Now the diverter-prism must be pulled into position to

direct light up the third ocular tube to the camera mounted on it.

REMEMBERWhat you see in the camera or on the image-

capture viewer is what will be saved to a digital file. NOT NECESSARILY what you see by eye through the eyepieces. BE SURE a final focus is made in the camera viewer or on the image-

capture viewer.

Page 18: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

REVIEW1) Be sure illuminator dimmer is turned all the way down before

selecting a light source on the scope.

2) Once the light source is selected, turn dimmer control up slowly

3) Move focusing head to a position on the support column that allows appropriate focusing

4) Focus on specimen at desired magnification

5) Adjust eyepieces for best viewing

6) Adjust illuminator for best lighting

7) “Zoom” to a different magnification if desired, refocus and readjust light

8) Divert image to camera, reposition specimen and fine focus on camera or image-capture viewer.

9) Capture desired image

Page 19: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Setting up a trinocular compoundmicroscope for best viewing

Page 20: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

“Trinocular” means three oculars, or eyepieces

Ocular tube for mounting a camera

Oculars for viewing by eye

Page 21: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

“Compound” means having multiple objective (lower) lenses mounted on

a rotating turret (lens holder)

Rotating turret to hold objective lenses

Objective lenses

Page 22: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Focusing the microscope on specimen slides can be accomplished with a coarse adjustment control for rapid adjustment, and a fine control for small adjustments, particularly

necessary at high magnification levels.

Coarse control

Fine control

Page 23: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

The “mechanical stage” holds specimen slides and allows them to be moved precisely under objective

lenses to focus on any area of interest.

Stage positioning

controls

Page 24: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

The microscope illuminator, or light source, provides light for transmission through the specimen for viewing its structure. The amount of light is modified with a

IlluminatorDiaphragm control

shutter or diaphragm using acontrol knob to open or close itfor more or less light.

Page 25: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

The condenser focuses light from the illuminator onto the specimen slide to provide the best lighting for viewing. It can be raised or lowered and centered for precise focusing as necessary.

It has its own shutter diaphragm too, for varying the amount of light reaching the specimen slide.

Focusing knobs

Centering controls

Diaphragm control

Page 26: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

To send light from the microscope to a camera mounted on the third ocular tube, a diverter-prism is moved into the field of view by pulling out its control arm.

Page 27: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Setting up a microscope for best viewing involves adjusting the parts of the scope to the viewer, focusing the

scope on the specimen slide and adjusting the illuminator or light source

to the slide being viewed.

Page 28: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Turn on microscope illuminator by rotating dimmer knob slowly clockwise. Fast turn-on shortens bulb life.

Dimmer knob

Page 29: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Place a sample slide on the microscope stage under the lowest power objective lens.

Page 30: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Adjust the microscope eyepieces so you can comfortably see a well-focused image through both

Space eyepieces so you can comfortably see through both at the same time.

If one eyepiece tube is fixed focus, close the opposite eye and, using the microscope focusing knob, carefully focus an image of the sample for the open eye. (If both eyepiece tubes are variable focus, either one will do.) Now close the other eye and use the variable focus eyepiece tube to bring the image into focus for the open eye.

Page 31: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

4X 40X

Focus on the specimen slide (e.g. these wood cells from a piece of paper). Using the 4X objective lens, there will be a much larger field of view but much less detail visible than

with the 40X lens.

Page 32: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

4X 40X

Rotate the illuminator diaphragm control until the diaphragm is closed all the way. Using the focusing knob on the condenser, bring the diaphragm image into as sharp focus as possible. Using the centering controls, be sure the diaphragm image is positioned in the center of the field of view.

Page 33: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Adjust the condenser diaphragm so that the specimen features are as clearly visible as desired.

Condenser diaphragm wide open

Condenser diaphragm closed down to provide correct contrast for clear viewing

Page 34: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

The nature of light and lenses results in a plane of focus which becomes thinner as magnification increases. That means for a particular specimen slide, it becomes possible to focus through

the thickness of a specimen. Some parts will be in focus while others will not, as in these wood cells focused at different “depths” through the slide.

Compare

Page 35: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

As with any images used for diagnoses, relative size is extremely important. Whenever possible, a comparative scale should be included with an image, or at least the approximate magnification indicated.

cm.

approx. 100X

Page 36: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

When the microscope has been adjusted to produce the best image of a specimen, it is

ready for capturing with the camera. Now the diverter-prism must be pulled into position to

direct light up the third ocular tube to the camera mounted on it.

REMEMBER

What you see in the camera or on the image-capture viewer is what will be saved to a digital file. NOT NECESSARILY what you see by eye

through the eyepieces. BE SURE a final focus is made in the camera viewer or on the image-

capture viewer.

Page 37: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

REVIEW

1)Turn on microscope illuminator slowly.

2) Place specimen slide on mechanical stage

3) Focus on specimen at desired magnification

4) Adjust eyepieces for best viewing

5) Adjust condenser for best lighting

6) Adjust condenser diaphragm for best contrast

7) Refine focus for depth of field

8) Refine focus for image capture

9) Capture image

Page 38: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Capturing Microscope Images

An analog video camera can be adapted to a microscope and individual video frames captured and converted to digital image files. Images at least 640x480 pixels in size are best, saved as JPG files. (Digital video cameras are now available too, with USB output.)

Page 39: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Capturing Microscope Images

(continued)

The same camera may be used on compound as well as dissecting scopes with the proper adapter. The system can be adjusted so that the viewed image is par focal on either scope.

Page 40: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

An image-capture device is required when using an analog camera.

Capturing Microscope Images (continued)

Page 41: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

Capturing Microscope Images (continued)

Many hand-held digital cameras can be adapted to capture images from microscopes. Very high resolution images produce unnecessarily large image files, so the camera should be set to a lower resolution and to JPG file type for this process.

Page 42: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

REVIEW

1)A video camera can be used to capture images from microscopes

2) With the proper adapter, the same camera can be used on more than one microscope

3) When using an analog video camera, an image-capture device must be used to get an image into the computer

4) Many hand-held digital cameras can be adapted to capture images from microscopes too

5) A final fine focus must be made on the image- capture screen before capturing and image

Page 43: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

“Wireless” digitally assisted diagnosesFor certain virulent diseases or for especially valuable crops, time may be of the essence. In such cases it may be safer or more cost effective to transmit information and images of problem symptoms from thefield. Wireless connectivity is now possible, although transmission is slow and expensive and coverage is often poor and/or inconsistent. Also portable equip- ment for microscopic images is expensive.

Page 44: Use of microscopes prepared by Jennifer Gose DDDI Project Coordinator Consortium for Internet Imaging and Database Systems College of Agricultural and

REVIEW

1) Wireless transmission of information and images may be important in certain circumstances

2) Wireless Internet connectivity is becoming more consistent, but still relatively slow and expensive

3) Slow transmission speeds make short Web forms and small image sizes necessary for wireless digitally assisted diagnoses

4) Portable microscope equipment is often expensive and less capable then desktop equivalents

5) Specimen preparation in the field is difficult

6) On-call diagnostic support is required