unparalleled guidew ire redirection optionsstingray lp™ pro x nx3™ nhancer rx™ recross™ 210...

2

Upload: others

Post on 21-Dec-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: UNPARALLELED GUIDEW IRE REDIRECTION OPTIONSStingray LP™ Pro X NX3™ NHancer Rx™ ReCross™ 210 220 230 240 250 260 270 2 80 223 274 265 p

Usable length: 140 cm

Hydrophilic coated

Radiopaquea-traumatic tip

Exit port stylet lumen

Exit port tip lumenReinforced shaft

Exit marker at95 cm and 105 cm

Hub stylet lumen

Hub tip lumen

Removable stylet

TRUE DISTAL END VISIBILITY

SOFT RADIOPAQUE TIP &EXIT PORT MARKERS

1.5F

8 mm

12 mm

OVAL DISTAL SHAFT

MINIMIZES PROFILEIMPROVES TRACKABILITY

2.3F

Ø 0.48 mm

3.3F

UNIQUE GUIDEWIREREDIRECTION POSSIBILITIES

2 PROXIMAL EXIT PORTSIN OPPOSITE DIRECTIONS

RC1414025 2.3F/3.3F5F 2.6F/3.4F 0.014” 140 cm

MODELGUIDE CATHETERCOMPATIBILITY

DISTAL SHAFTPROFILE

PROXIMAL SHAFTPROFILE

GUIDEWIRECOMPATIBILITY

USABLELENGTH

SCAN CODE FORINSTRUCTION VIDEOS

Please see the Instructions for Use for a complete listing of the indications,contraindications, warnings and precautions.Caution: Federal Law (U.S.) restricts this device to sale by or on the order of a physician.In-vitro test data on file at IMDSBench test data may not be indicative of clinical performance.ReCross™ is a trademark of IMDS.

© IMDS 2020 ITM200184 R1.0

Ceintuurbaan Noord 1509301 NZ RodenThe [email protected]

Phone +31(0)50 8200230Fax +31(0)50 8200231

MADE IN

EU0344

UNPARALLELED GUIDEWIRE

REDIRECTION OPTIONS

WWW.IMDS.NL

Page 2: UNPARALLELED GUIDEW IRE REDIRECTION OPTIONSStingray LP™ Pro X NX3™ NHancer Rx™ ReCross™ 210 220 230 240 250 260 270 2 80 223 274 265 p

Stingray LP™

Pro X NX3™

NHancer Rx™

ReCross™

0.66

0.34

0.62

0.62

Distal crossing surface (mm2)

OVAL DISTAL SHAFTMINIMIZING CROSSING PROFILE

6F GUIDING CATHETERCOMPATIBILITY

Stingray LP™ Pro X NX3™ NHancer Rx™ ReCross™

210

220

230

240

250

260

270

280

274 265223

p<0.001

225

p<0.001

Catheter crossing depth (mm)

Stingray LP™ Pro X NX3™ NHancer Rx™ ReCross™

4

6

8

10

12

14

16

18

6.8 16.6 16.1 16.6

p<0.001

Catheter tip penetration force (gf)

STRONG FRONTLINE CROSSING ANDPENETRATION WHEN NEEDED

Stingray LP™ Pro X NX3™ NHancer Rx™NHancer Rx™+ Stylet

ReCross™ReCross™+ Stylet

80

0

60

100

120

140

160

180

200

Force transferred (gf)

p<0.001

p<0.001

p<0.001

82 178 118 191 151 193

REMOVABLE STYLETPROVIDES SIGNIFICANT PUSHABILITY IMPROVEMENT

360̊ CIRCUMFERENTIAL ACCESS DUAL LUMENENABLES UNIQUE & EFFECTIVE PROCEDURES

UNPARALLELED GUIDEWIRE REDIRECTION OPTIONS

VERSATILITY FOR EVERYDAY EFFICIENCYANTEGRADEDUAL ACCESS (ADA)

SUBINTIMAL GUIDEWIREREDIRECTION (SGR)

PRECISE TARGETING OF SIDE BRANCHOCCLUSION

HEMATOMADECOMPRESSION