twinset manifolds
DESCRIPTION
Twinset Manifolds. KIT SET UP BEFORE DIVING. 1 st stage. regs. Right post. Left post. isolator. knob. knob. Gas always flows. cylinder. cylinder. GASES OFF. NORMAL DIVING. Breathing off right hand regulator. 1 st stage. regs. Right post. Left post. Isolator open. Knob open. - PowerPoint PPT PresentationTRANSCRIPT
Right post Left post
knob knob
isolator
Gas always flows
cylindercylinder
KIT SET UP BEFORE DIVING
1st stageregs
GASES OFF
Right post Left post
Knobopen
Knobopen
Isolator open
cylindercylinder
NORMAL DIVING
1st stageregs
Breathing off right hand regulator
Right post Left post
Knobopen
Knobopen
Isolator open
cylindercylinder
RIGHT REG STARTS TO FREE FLOW
1st stageregs
Right post Left post
KnobCLOSED
Knobopen
Isolator open
cylindercylinder
RIGHT REG FREE FLOW
1st stageregs
SWITCH TO LEFT REG
Right post Left post
Knobopen
Knobopen
Isolator open
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
Right post Left post
Knobopen
Knobopen
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
CHECK SPG ON LEFT FIRST STAGE
If it decreases rapidly the leak is somewhere on the left sideIf it remains constant the leak is on the right side
Right post Left post
Knobopen
Knobopen
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
CHECK SPG ON LEFT FIRST STAGE
It falls rapidly
Right post Left post
Knobopen
KnobCLOSED
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
TURN LEFT OFF
Right post Left post
Knobopen
KnobCLOSED
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
LEAK STOPS
Right post Left post
Knobopen
KnobCLOSED
Isolator OPEN
cylindercylinder
UNKNOWN GAS RELEASE
regs
Breathing off right hand regulatorLeak must have been1st stage on left side
Right post Left post
Knobopen
KnobCLOSED
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
LEFT CYLINDER WILL EMPTY
Leak must be left side ofisolator valve on where pillarvalve screws into cylinder
Right post Left post
Knobopen
Knobopen
Isolator open
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
Right post Left post
Knobopen
Knobopen
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
CHECK SPG ON LEFT FIRST STAGE
If it decreases rapidly the leak is somewhere on the left sideIf it remains constant the leak is on the right side
Right post Left post
Knobopen
Knobopen
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
1st stageregs
Breathing off right hand regulator
CHECK SPG ON LEFT FIRST STAGE
No movement
Right post Left post
KnobCLOSED
Knobopen
Isolator CLOSED
cylindercylinder
UNKNOWN GAS RELEASE
regs
Switch to left hand regulator
Breathing off LEFT cylinder only
Right post Left post
KnobCLOSED
Knobopen
Isolator OPEN
cylindercylinder
UNKNOWN GAS RELEASE
regs
Breathe off left hand regulator
Breathing off BOTH cylinders
Right post Left post
KnobCLOSED
Knobopen
Isolator OPEN
cylindercylinder
UNKNOWN GAS RELEASE
regs
Breathe off left hand regulator
Breathing off BOTH cylinders
Leak must have been1st stage on right side
Right post Left post
knob knob
isolator
Gas always flows
cylindercylinder
KIT SET UP BEFORE DIVING
1st stageregs
GASES OFF
Right post Left post
knob knob
Isolator OFF
cylindercylinder
1st stageregs
GASES OFF
RIGHT CYLINDER WILL EMPTY YOU’VE SAVED THE LEFT
WORSE STILL – YOU BREAK THE MIDDLE
Somebody carries the twinset by the manifoldYou bump the manifold inside a wreck
Right post Left post
knob knob
isolator
cylindercylinder
1st stageregs
Doesn’t matter if isolator valve isOPEN or SHUT
YOU LOSE ALL GASES FROM BOTH CYLINDERS