T/TE2 Thermostatic Expansion Valves. T/TE 2 Thermostatic Expansion Valves. The T2 thermostatic expansion valve family is the most universal and adaptable in the world : Wide capacity range Wide temperature range All new and old standard refrigerants With MOP and without MOP. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 1

Refrigeration andAir Conditioning

Expect morefrom us

T/TE2 Thermostatic Expansion Valves

Page 2: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 2

Refrigeration andAir Conditioning

Expect morefrom us

T/TE 2 Thermostatic Expansion Valves

The T2 thermostatic expansion valve family is the most universal and adaptable in the world:

• Wide capacity range• Wide temperature range• All new and old standard refrigerants• With MOP and without MOP

Page 3: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 3

Refrigeration andAir Conditioning

Expect morefrom us

Danfoss T&TE 2 Thermostatic Expansion Valves

forLiquid Injection into Evaporators

Type T/TE 2 from 0.2 to 4.5 TR nominal capacity with 8 orifices

Page 4: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 4

Refrigeration andAir Conditioning

Expect morefrom us

Multi room installation

Page 5: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 5

Refrigeration andAir Conditioning

Expect morefrom us

T2 system pipe diagram

Page 6: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 6

Refrigeration andAir Conditioning

Expect morefrom us

T/TE 2 Thermostatic Expansion Valve

The T/TE 2 will control and maintain the amount of refrigerant to beinjected into the Evaporator.

It does this by keeping the Superheat Constant where the sensor is mounted on the suction line(In a constant load scenario)

Page 7: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 7

Refrigeration andAir Conditioning

Expect morefrom us

T/TE 2 Body Types

T 2, Internal Equalizing, two connectionsInlet ¼” or 3/8” flare or solderOutlet ½” flare or solder

TE 2, External Equalizing, three connectionsInlet ¼” or 3/8” flare or solderOutlet ½” flare or solderEqualizing ¼” flare or solder

T/TE 2, All Normal Refrigerants

Page 8: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 8

Refrigeration andAir Conditioning

Expect morefrom us

Ranges:N, -40/+10°CN, -40/+10°C, MOP +15°CNM, -40/-5°C, MOP 0°CNL, -40/-15°C, MOP -10°CB, -60/-25°CB, -60/-25°C, MOP -20°C

Standard program:R22 R12R134a R502R404A/R507NOT: R410A

Special program:R23 + variousR407C

REFRIGERANTS & RANGES

Page 9: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 9

Refrigeration andAir Conditioning

Expect morefrom us

T/TE 2 THERMOSTATIC EXPANSION VALVES

Page 10: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 10

Refrigeration andAir Conditioning

Expect morefrom us

Type : T2 / TE2Refrigerants CFC / HCFC / HFCMedia temp. oC -40 - +10, Range N

-40 - -5, Range NM -40 - -15, Range NL -60 - -25, Range B

Max. bulb oC 100 installedMWP / PB bar 34Max. test pressure 37

TECHNICAL DATA

Page 11: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 11

Refrigeration andAir Conditioning

Expect morefrom us

T/TE 2 Cut-away Model

Page 12: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 12

Refrigeration andAir Conditioning

Expect morefrom us

Label

Page 13: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 13

Refrigeration andAir Conditioning

Expect morefrom us

Function of the T/TE 2

The TEV will try to keep a constant superheat at a constant load situationIf there is a change in load the TEV will open more at increasing load and open less at decreasing load, and again try to keep a constant superheatThe opening degree is decided by a balance between the opening force and the closing forces• Pressure in the Power element is the opening force (Sensor temperature)• Pressure from the refrigerant is a closing force• Pressure from the spring is the other closing force

Page 14: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 14

Refrigeration andAir Conditioning

Expect morefrom us

Compressor not running.TEV closed.

4.7 bar bulb pressure

0.7 bar spring

4.7 bar

4°C

4.7 bar

evaporator pressure

4.7

0.7 4.7

Valve in

equilibrium

4°C

4.7 bar

R22

Page 15: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 15

Refrigeration andAir Conditioning

Expect morefrom us

Thermostatic expansion valve is now operating at constant superheat.

3.85 bar bulb pressure

0.7 bar spring

3.8 bar

-1,05°C

3.1 bar

evaporator pressure

Valve constant opening degree

-6°C

3.1 bar

R22

3.8

0.7 3.1

Page 16: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 16

Refrigeration andAir Conditioning

Expect morefrom us

Thermostatic expansion valve operating at slightly reduced load.

3.79 bar bulb pressure

0.7 bar spring

3.79 bar

-1.1°C

3.1 bar

evaporator pressure

Valve closing little

-6°C

3.1 bar

R22

3.79

0.7 3.1

Page 17: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 17

Refrigeration andAir Conditioning

Expect morefrom us

Thermostatic expansion valve operating at increased load.

3.85 bar bulb pressure

0.7 bar spring

3.85 bar

-0.73°C

3.1 bar

evaporator pressure

Valve opening

-6°C

3.1 bar

R22

3.85

0.7 3.1

Page 18: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 18

Refrigeration andAir Conditioning

Expect morefrom us

The compressor is stopped,TEV positively closed.

4.7 bar bulb pressure

0.7 bar spring

4.7 bar

4°C

4.7 bar

evaporator pressure

Valve closed during standstill

4°C

4.7 bar

R22

4.7

0.7 4.7

Page 19: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 19

Refrigeration andAir Conditioning

Expect morefrom us

Superheat

Valve Capacity

Reserve Capacity

Rated Capacity

Full Open Capacity

SS OS

OPS

Capacity / superheat relationship

Page 20: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 20

Refrigeration andAir Conditioning

Expect morefrom us

Adjusting the T/TE 2

In most cases it is not necessary to adjust the T/TE 2

If you have the experience, to improve the system performance by adjusting the valve, please do so

Page 21: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 21

Refrigeration andAir Conditioning

Expect morefrom us

Adjusting the TEV

Page 22: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 22

Refrigeration andAir Conditioning

Expect morefrom us

Adjusting the TEV

Page 23: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 23

Refrigeration andAir Conditioning

Expect morefrom us

Changing the Orifice

Page 24: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 24

Refrigeration andAir Conditioning

Expect morefrom us

Changing the Orifice, solder version

Page 25: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 25

Refrigeration andAir Conditioning

Expect morefrom us

Using the T/TE 2

Why ?When ?How ?Where ?Recommendations !

Page 26: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 26

Refrigeration andAir Conditioning

Expect morefrom us

WHY ?

To be able to accurately injectthe amount of refrigerant requiredinto the evaporator.

Page 27: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 27

Refrigeration andAir Conditioning

Expect morefrom us

WHEN ?

Every time there is a refrigeration system there should be one TEV for each evaporator (If not another means of throttle device is used)

Page 28: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 28

Refrigeration andAir Conditioning

Expect morefrom us

HOW ?

By mounting the TEV in the refrigeration circuit with any necessary adjustment

Page 29: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 29

Refrigeration andAir Conditioning

Expect morefrom us

Where ?

Always at the inlet of the evaporator

Page 30: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 30

Refrigeration andAir Conditioning

Expect morefrom us

Adjust if you want to optimize evaporator performance

Adjust if the TEV is hunting

Recommendations !

Page 31: T/TE2  Thermostatic Expansion Valves

Refrigeration andAir Conditioning

Expect morefrom us

T-TE 2 Product Presentation - 2001.07.23, JBM page 31

SIZING THE T/TE2

The Catalogue WayThe Electronic Way

Page 32: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 32

Refrigeration andAir Conditioning

Expect morefrom us

The Sales Features

• Hot Stamped Brass Body• Metal to metal push pin/guide• Stainless steel bulb• Stainless steel capillary• Stainless steel capsule and diaphragm• Laser welding• Laser engraving• Double contact bulb• Eight interchangeable orifices• Stainless steel seat and cone• Generous inlet filter• Six charge versions (Range/MOP)• Automated production (ISO 9002)

Page 33: T/TE2  Thermostatic Expansion Valves

T-TE 2 Product Presentation - 2001.07.23, JBM page 33

Refrigeration andAir Conditioning

Expect morefrom us

The Competition

• Primary :- Alco TI(E) (T2 Copy)- Egelhof TEW (T2 Copy)- Flica TMV (T2 Copy)- Sporlan Q

• Secondary :- FAS (T2 Copy)- Parker- Saginomiya- Fuji Koki- Teddington TED (T2 Copy)