trimble fmx display kit installation manual · 1 introduction the trimble fmx display kit manual is...

14
Trimble FMX Display Kit Installation Manual 54VT-TB-FMX

Upload: others

Post on 26-Aug-2020

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

Trimble FMX Display Kit

Installation Manual 54VT-TB-FMX

Page 2: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

Printed in Canada Copyright 2015 by NORAC Systems International Inc. Reorder P/N: 54VT-TB-FMX-INST Rev B (Trimble FMX Display Kit)

NOTICE: NORAC Systems International Inc. reserves the right to improve products and their specifications without notice and without the requirement to update products sold previously. Every effort has been made to ensure the accuracy of the information contained in this manual. The technical information in this manual was reviewed at the time of approval for publication.

Page 3: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

1

Contents

1  INTRODUCTION ...................................................................................................... 2 

1.1  List of Parts ..........................................................................................................................................................................2 

1.2  Alternate Cabling ................................................................................................................................................................2 

2  INSTALLATION ........................................................................................................ 3 

2.1  Self-Propelled .......................................................................................................................................................................3 

2.2  Pull Type ...............................................................................................................................................................................4 

2.3  Switch Box Installation ......................................................................................................................................................7 

3  CABLE DRAWINGS .................................................................................................. 8 

3.1  ITEM C25: 44602-01 – Switch Remote Hand Control .............................................................................................8 

3.2  ITEM C26: 43240-26 – Cable UC5 Switch Box ..........................................................................................................9 

3.3  ITEM C40: 43260-30 – Cable UC5 Interface DTM 4 Pin 12in Stub .................................................................... 10 

3.4  ITEM C41: 43220-03 - Cable UC5 Network 14 AWG - 3M ............................................................................... 11 

Page 4: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

2

1 Introduction

The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray Height Control Installation Manual. This manual provides instructions to interface the UC5 Control Module to the Trimble FMX Display. For installation of the rest of the UC5 Spray Height Control System please refer to the sprayer specific manual provided with the kit.

1.1 List of Parts

Item Part Number Name Quantity

C25 44602-01 BOX SWITCH UC4 REMOTE HAND CONTROL VER.1 RMR 1

C26 43240-26 CABLE UC5 INTERFACE SWITCH BOX 1

C40 43260-30 CABLE UC5 INTERFACE DTM 4 PIN 12 IN STUB 1

C41 43220-03 CABLE UC5 NETWORK 14 AWG 3M 1

E12 43764 UC5 NETWORK COUPLER 2-WAY 1

M01 UC5-BC-MANUAL-ECHO-VT MANUAL UC5 OPERATORS - ECHO/VT 1

M04 54VT-TB-FMX-INST MANUAL UC5 DISPLAY KIT TRIMBLE FMX 1

Trimble FMX version must be 8.0 or higher.

Trimble part numbers are subject to change without notice.

1.2 Alternate Cabling

If the control module is mounted on the sprayer of a pull-type sprayer (non-ISOBUS ready tractor) (Section 2.2.3), cable C42 is required to replace C40. This cable can be ordered from NORAC.

Item Part Number Name Quantity

C42 43260-29 CABLE UC5 INTERFACE DT 4 PIN 12 IN STUB 1

Page 5: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

3

2 Installation

The following instructions are for installation on a self-propelled sprayer (Section 2.1) or pull type sprayer (Section 2.2).

2.1 Self-Propelled

1. Securely mount the control module (E01) inside the sprayer cab.

2. Tee the CANbus interface cable (C40) between the Trimble cable 75834 and the ISOBUS trunk cable that runs to the back of the sprayer.

3. Connect the 6 pin Deutsch plug on cable C40 to the end of the control module with only one Deutsch connector.

4. Connect cable C01 to the other CANbus connector and route the cable towards the rear of the sprayer.

Note: Not all cables listed in the List of Parts (Section 1.1) are used for this type of installation.

Figure 1: Self Propelled Sprayer Installation

Page 6: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

4

2.2 Pull Type

2.2.1 Control Module on Tractor (Non-ISOBUS Ready Tractor)

1. Securely mount the control module (E01) inside the tractor cab.

2. Tee the CANbus interface cable (C40) between Trimble cable 75834 and Trimble cable 77368.

3. Connect the 6 pin Deutsch plug on cable C40 to the end of the control module with only one Deutsch connector.

4. Connect cable C41 to the CANbus connector and route the cable to the hitch of the tractor. Connect the two-way coupler (E12) to the end of cable C41.

5. Connect cable C01 to the coupler (E12) and route towards the rear of the sprayer. The two-way coupler (E12) will provide the hitch disconnect.

Figure 2: Pull Type with Control Module on Non-ISOBUS Ready Tractor Installation

Page 7: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

5

2.2.2 Control Module on Tractor (ISOBUS Ready Tractor)

1. Securely mount the control module (E01) inside the tractor cab.

2. Tee the CANbus interface cable (C40) between Trimble cable 75407 and Trimble cable 92752.

3. Connect the 6 pin Deutsch plug on cable C40 to the end of the control module with only one Deutsch connector.

4. Connect cable C41 to the CANbus connector and route the cable to the hitch of the tractor. Connect the two-way coupler (E12) to the end of cable C41.

5. Connect cable C01 to the coupler (E12) and route towards the rear of the sprayer. The two-way coupler (E12) will provide the hitch disconnect.

Figure 3: Pull Type with Control Module on ISOBUS Ready Tractor Installation

Page 8: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

6

2.2.3 Control Module on Sprayer (Non-ISOBUS Ready Tractor)

Cable C42 is required for this type of installation. Please order the following cable from NORAC:

Item Part Number Name Quantity

C42 43260-29 CABLE UC5 INTERFACE DT 4 PIN 12 IN STUB 1

1. Securely mount the control module (E01) on the sprayer near the CANbus connection.

2. Tee the CANbus interface cable (C42) between Trimble cable 77368 and the IBRC connector.

3. Connect the 6 pin Deutsch plug on cable C42 to the end of the control module with only one Deutsch connector.

4. Connect cable C01 to the other CANbus connector and route the cable towards the rear of the sprayer.

Note: Not all cables listed in the List of Parts (Section 1.1) are used for this type of installation.

Figure 4: Pull Type with Control Module on Sprayer (Non-ISOBUS Ready Tractor) Installation

Page 9: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

7

2.3 Switch Box Installation

The switch box is an optional component to make the operation of the UC5 easier. An extra label is provided if the operator would like to remove the switches from the box and mount them in another location.

1. Disconnect cable C20 (Thru 2 connector) from the Input Module (E03). Remove the wedge from the face of the 12 pin Deutsch plug.

2. Insert the Roll CW pin from C26 into position 3 of the 12 pin plug on C20. Insert the Roll CCW pin from C26 into position 4 of the 12 pin plug on C20. Insert the wedge back into the plug. Connect C20 to the Thru 2 connector on the Input Module.

3. Connect the 12 pin Deutsch plug on C26 to the OEM 3 connector on the input module. Route the other end of the cable to the hitch of the sprayer (pull type) or to the cab (self propelled).

4. Attach the switch box (C25) inside the cab and connect it to cable C26. An extra label is provided with the switch box if you prefer to remove the switches from the housing and mount them in the existing sprayer switch panel.

* Some sprayer types may not use all the switch functions.

Figure 5: Switch Box Installation

Page 10: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

8

3 Cable Drawings

3.1 ITEM C25: 44602-01 – Switch Remote Hand Control

Page 11: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

9

3.2 ITEM C26: 43240-26 – Cable UC5 Switch Box

Page 12: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

10

3.3 ITEM C40: 43260-30 – Cable UC5 Interface DTM 4 Pin 12in Stub

Page 13: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

11

3.4 ITEM C41: 43220-03 - Cable UC5 Network 14 AWG - 3M

Page 14: Trimble FMX Display Kit Installation Manual · 1 Introduction The Trimble FMX Display Kit Manual is intended to be used in conjunction with the UC5 Spray ... If the control module

Canada NORAC Systems International Inc.

Phone: (+1) 306 664 6711 Toll Free: 1 800 667 3921

Shipping Address: 3702 Kinnear Place

Saskatoon, SK S7P 0A6

United States NORAC, Inc.

Phone: (+1) 952 224 4142 Toll Free: 1 866 306 6722

Shipping Address: 6667 West Old Shakopee Road, Suite 111

Bloomington, MN 55438

Europe NORAC Europe

Phone: (+33) (0)4 26 47 04 42 Shipping Address:

Rue de l’hermitage 01090 GUEREINS

France

www.norac.ca