tricklestar, ins1125-1, manual, humidity controller, 601cc ... · humidity controller 601cc-us-w...

2
601CC-US-W www.tricklestar.com HUMIDITY CONTROLLER 601CC-US-W INSTRUCTIONS (ENGLISH) Introduction Thank you for purchasing this TrickleStar TM product. This product provides enhanced controls to reduce wasteful energy consumption of dehumidifying, humidifying and heating appliances, which do not include humidity controls. This product is suitable for the control of devices such as dehumidifiers, humidifiers and electrical heaters. LCD Display Factory Default Setting The factory default settings are: Dehumidify Mode and a humidity “SET POINT” of 40%. Status Indication Off Product is OFF Green Product is ON and Control Socket is ON Red Product is ON and Control Socket is OFF Application / Installation Plug the product into a wall outlet and plug an appliance to be controlled into the Control Socket. Select Dehumidify / Humidify Mode To switch between Dehumidify and Humidify Modes, switch the product OFF using the Button. Press the button and button simultaneously for 3 seconds to switch between Dehumidify and Humidify Mode. Dehumidifying Mode Setup 1. Select Dehumidify Mode. 2. Press button to switch product ON. 3. Press or button to adjust to the required humidity Set- point. Dehumidifying Mode Operation When room humidity is higher than the Target Set-point , the Status Indicator will illuminate GREEN and the Control Socket will switch ON within 3 min. When room humidity is lower than the Target Set-point , the Status Indicator will illuminate RED and the Control Socket will switch OFF within 3 minutes. Humidifying Mode Setup 1. Select Humidify Mode. 2. Press button to switch product ON. 3. Press or button to adjust the humidity Set-point. Humidifying Mode Operation When room humidity is lower than the Set-point , the Status Indicator will illuminate GREEN and the Control Socket will switch ON within 3 min. When room humidity is higher than the Set-point the Status Indicator will illuminate RED and the Control Socket will switch OFF within 3 minutes. Down Button On / Off Button Status Indicator Reset Button LCD Display Control Socket Up Button Humidity Sensor RM SET 80 Room Humidity De-Humidify Mode Humidify Mode Target Humidity Set-point Set Humidity Set-point Percentage % 88 8 . % SET De-Humidify Humidify SET SET SET SET

Upload: others

Post on 19-Aug-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TrickleStar, INS1125-1, Manual, Humidity Controller, 601CC ... · HUMIDITY CONTROLLER 601CC-US-W INSTRUCTIONS (ENGLISH) Introduction Thank you for purchasing this TrickleStarTM product

601CC-US-W

www.tricklestar.com

HUMIDITY CONTROLLER 601CC-US-W

INSTRUCTIONS (ENGLISH)

Introduction Thank you for purchasing this TrickleStarTM product. This product provides enhanced controls to reduce wasteful energy consumption of dehumidifying, humidifying and heating appliances, which do not include humidity controls. This product is suitable for the control of devices such as dehumidifiers, humidifiers and electrical heaters.

LCD Display

Factory Default Setting The factory default settings are: Dehumidify Mode and a humidity “SET POINT” of 40%.

Status Indication Off Product is OFF Green Product is ON and Control Socket is ON Red Product is ON and Control Socket is OFF

Application / Installation

Plug the product into a wall outlet and plug an appliance to be controlled into the Control Socket.

Select Dehumidify / Humidify Mode To switch between Dehumidify and Humidify Modes, switch the product OFF using the Button. Press the button and button simultaneously for 3 seconds to switch between Dehumidify and Humidify Mode.

Dehumidifying Mode Setup 1. Select Dehumidify Mode. 2. Press button to switch product ON. 3. Press or button to adjust to the required humidity Set-

point.

Dehumidifying Mode Operation When room humidity is higher than the Target Set-point

, the Status Indicator will illuminate GREEN and the Control Socket will switch ON within 3 min. When room humidity is lower than the Target Set-point , the Status Indicator will illuminate RED and the Control Socket will switch OFF within 3 minutes.

Humidifying Mode Setup 1. Select Humidify Mode. 2. Press button to switch product ON. 3. Press or button to adjust the humidity Set-point.

Humidifying Mode Operation When room humidity is lower than the Set-point , the Status Indicator will illuminate GREEN and the Control Socket will switch ON within 3 min. When room humidity is higher than the Set-point the Status Indicator will illuminate RED and the Control Socket will switch OFF within 3 minutes.

Down ButtonOn / Off Button

Status IndicatorReset ButtonLCD Display

Control Socket

Up Button

Humidity Sensor

RM SET

80

Room Humidity De-Humidify ModeHumidify Mode

Target HumiditySet-point

Set HumiditySet-point

Percentage%888. %

SETDe-HumidifyHumidify

SET

SET

SET

SET

Page 2: TrickleStar, INS1125-1, Manual, Humidity Controller, 601CC ... · HUMIDITY CONTROLLER 601CC-US-W INSTRUCTIONS (ENGLISH) Introduction Thank you for purchasing this TrickleStarTM product

601CC-US-W

www.tricklestar.com

Restore Factory Defaults Press the Reset Button for 2 seconds to restore factory defaults.

Battery The product contains a rechargeable battery to store settings if power is removed. If the battery level is low, a “LO” icon will flash in the display. Connect the product to a power outlet for 1 hour to recharge the battery. If the battery is fully discharged, the factory defaults will be restored.

Electrical and Environmental Specifications Voltage 125 VAC / 60Hz

Power Rating: 16A / 3680W – Resistive

Load 2A / 460W – Inductive Load

Humidity Control Range 10% - 90% N/C

Humidity Measuring Range 10% - 90% N/C

Measurement interval 10 sec.

Switching hysteresis Up to 3 minutes

Operating Temperature -10° to 40°C

Storage Temperature -10ºC to 70ºC

Storage Humidity 5 to 95% N/C

IMPORTANT SAFETY NOTICES • Fans or other appliances with exposed elements should not

be left unattended. • FOR INDOOR USE ONLY • SUITABLE FOR NON-CONDENSING ENVIRONMENTS

ONLY.

Approvals US ELECTRICAL & SAFETY OTHER

ETL 2002/95/EG (RoHs) 2002/96/EC (WEEE) 1999/5/EC (RTTE)

Warranty www.tricklestar.com/warranty

Copyright & Disclaimer © TrickleStar Ltd. All rights reserved. TrickleStarTM is a registered trademark of TrickleStar Ltd. Disclaimer: TrickleStar reserves the right to change specifications or designs described in this manual without notice and without obligation. Any typographical, clerical or other error or omission in this document or other documents or information issued by TrickleStar shall be subject to correction without any liability on the part of TrickleStar without notice. Conserving Energy. Improving Life. www.tricklestar.com