trenton sweet sales rep

36
Trenton Sweet Sales Rep Office 303-651-5500 X-8115 Aqua-Hot Contact Information

Upload: others

Post on 22-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Trenton Sweet Sales Rep

Trenton Sweet

Sales Rep

Office 303-651-5500 X-8115

Aqua-Hot Contact Information

Page 2: Trenton Sweet Sales Rep

Aqua-Hot Contact Information

Aqua-Hot Heating Systems Inc.

7501 Miller Drive | Frederick, CO 80504

P: 303-651-5500 | TF: 800-685-4298

[email protected]

www.aquahot.com

Page 3: Trenton Sweet Sales Rep

Aqua-Hot

Four Systems in One

Interior Heating System

Hot Water System

Bay Heating System

Engine Pre-Heating System*

* Not included on 400D, 400P or 250

Systems

Page 4: Trenton Sweet Sales Rep

What is Hydronic Heating?

is heatingusing liquid

Page 5: Trenton Sweet Sales Rep

General Layout

Aqua-Hot

KitchenBathroom

Engine Preheating

Page 6: Trenton Sweet Sales Rep

TribridHot™

Technology

(N/A on 400D /LP or 250

Systems

Three Heat

Sources

Page 7: Trenton Sweet Sales Rep

Interior Heating

Page 8: Trenton Sweet Sales Rep

Interior

Heating

2 or 3

Circulation

Zones

Up to 5

Temperature

Zones

Page 9: Trenton Sweet Sales Rep

Continuous On-Demand Hot

Water

Page 10: Trenton Sweet Sales Rep

Engine Pre-Heating

Aqua-Hot’s pump circulates the engine’s coolant

with the engine off.

(N/A on 400D and 400LP)

Page 11: Trenton Sweet Sales Rep

TribridHot™

Three Sources of Heat

Page 12: Trenton Sweet Sales Rep

Cut-A-Way

Interior Heating Zone

Circulation

Pumps

Domestic Hot Water LoopBoiler Tank

Engine Preheating

LoopElectrical Element

Diesel Burner

Heating Zone

Outlets

Heating Zone Returns450D

Page 13: Trenton Sweet Sales Rep

COMFORT

Aqua-Hot Forced Air

Even heat distribution Uneven Heat Distribution

No cold or hot spots Hot and Cold Spots

5⁰ temperature difference from

floor to ceiling

30⁰ temperature difference from

floor

to ceiling.

Heats bay area keeping pipes

and tanks from freezing

Auxiliary heat needed to keep

bay warm in cold climates

Does not super-heat air Super heats the air

No loss of humidity40% drop in humidity from

outside to inside coach

Moist, comfortableCauses discomfort:

dry skin, eyes, nose and sinuses

Page 14: Trenton Sweet Sales Rep

COMFORT

Aqua-Hot Forced Air

Super quiet Very Loud

Low speed

quiet fansHigh speed fans

Burner in bay area Burner in living area

No need to turn up the TV or radio

every time the heater comes on

Difficult to hear.

May wake people from sleep

Aqua-Hot Water Heater/Furnace

TribridHot™

Pulls heat from one or a combination

of heat sources. Single fuel source

Uses fuel only when necessary

Always uses propane when heating

regardless of operating environment

Page 15: Trenton Sweet Sales Rep

COMFORT

Aqua-Hot Water Heater

Continuous hot water Limited to 6 – 16 gallons

Tankless system Tank

Zero recovery time 30 – 60 minutes

Consistent temperature Inconsistent temperature

Page 16: Trenton Sweet Sales Rep

Aqua-Hot Water Heater/Furnace

TribridHot™

Pulls heat from one or a

combination of heat sources. Single fuel source

Uses fuel only when

necessary

Always uses propane when

heating regardless of

operating environment

COMFORT

Page 17: Trenton Sweet Sales Rep

COMFORT

Aqua-Hot Block Heater

Preheats diesel engine in

one hour 30⁰ to 90⁰

12 Hours

No engine wear

Cold engine starting causes

70% of all engine wear

Aqua-Hot Idling

Less than ¼ Gallon/Hr 1 to 2 Gallon/Hr

No Engine Wear Causes more engine wear

than cold starting

Page 18: Trenton Sweet Sales Rep

Aqua-Hot Product

Specifications

Interior Heating 450D 400D *Provides Interior Heat Yes Yes

Separate Thermostatic Heating Zones Up to 5 Up to 5

Zone Heating Circulation Loops 2 2

Maximum Number of Aqua-Hot Cozy Heat Exchangers 8 8

Heating BTUs 65,600 65,600

Hot WaterDomestic Hot Water Supply Continuous Continuous

Domestic Water Temp/Flow Rate 120⁰ 1.5GPM 120⁰ 1.5GPM

Gallons per Hour (Continuous) 90 90

Recovery Time None None

Engine PreheatingPreheats Diesel Engine Yes No

Time Required to Preheat

Engine 30⁰f - 90⁰f 1 Hour N/A

Number of Engine Preheat Pumps 1 0

Page 19: Trenton Sweet Sales Rep

Aqua-Hot Product

Specifications

Power Sources 450D 400D *Number of Power Sources 3 3

Fuel Diesel Diesel

Maximum Fuel Usage (Running Continuously) .41 Gal/Hr .41 Gal/Hr

Fuel Usage (Average per day Dry Camping) 2-4 Gal 2-4

Fuel Usage /Day (When Elec is available) 1-2 Gal 1-2

Fuel Usage (When Driving) None .5-2

Shore Power (Low and High Settings) No No

Electric Heating Element(s) 1-120V, 1650W

Shore Power Operating Requirements

120V AC

30 Amps

120V AC

30 Amps

Engine's Surplus Heat (When Driving) Yes No

Page 20: Trenton Sweet Sales Rep

COMFORT

Page 21: Trenton Sweet Sales Rep

AquaHot.com

Page 22: Trenton Sweet Sales Rep

www.aquahot.com Library Page

• Owners Manuals• Installation Manuals• Service Manuals• Parts Manuals

Page 23: Trenton Sweet Sales Rep

www.aquahot.com Library Page

Page 24: Trenton Sweet Sales Rep

www.aquahot.com Service Help Page

Page 25: Trenton Sweet Sales Rep

www.aquahot.com Service Help Page

• Find a Service Center• Service Center Map• Warranty Registration• Service Contact Info

Page 26: Trenton Sweet Sales Rep

Aqua-Hot Electronic Controls

Aqua-Hot Electronic Control Board

Aqua-Hot 4” Touch Screen

“The Reporter”

Page 27: Trenton Sweet Sales Rep

AquaHot Reporter- your place for Aqua-Hot information

Page 28: Trenton Sweet Sales Rep

Aqua Hot Reporter- Your place for Aqua-Hot information

Click here for extensive information on the Aqua Hot Reporter

Page 29: Trenton Sweet Sales Rep

Monthly Preventive Maintenance

Continuous hot water .8 gpm at 120 degrees F

• Keeps the check valves from sticking in the heating zones

• Keeps the nozzle from clogging

• Turn Diesel Burner on

• Turn Thermostat to heat

• Set thermostat high enough for the heat to come on

• Wait 5 minutes and make sure you feel heat at the heat exchanger

Exercise the Aqua-Hot Monthly

Why?

Page 30: Trenton Sweet Sales Rep

Exercise Mixer Valve

Mixer

Valve

Mixer Valve mixes hot & cold

water

Page 31: Trenton Sweet Sales Rep

Winterizing your Aqua-Hot

Continuous hot water .8 gpm at 120 degrees F

Domestic Hot Water Loop

• When the motorhome is stored where

freezing temperatures may be

experienced, exposing the system to

freezing temperatures, the domestic

hot water system must be winterized.

• The Aqua-Hot can still be used for

interior zone heating once the

domestic hot water system is

winterized.

• If the system is not winterized the

copper coil could freeze and burst.

• The Domestic Hot Water loop can only be

winterized by ruining RV wintering fluid thru

the Hot water lines in the RV. NOT blowing

them out with air.

Page 32: Trenton Sweet Sales Rep

Annual Preventive Maintenance

Continuous hot water .8 gpm at 120 degrees F

• Replace the nozzle on the burner• Replace the fuel filter• * Not Required Propane models

• Check for proper fill

level (when hot)

• Check % Propylene

Glycol (when cold)

using a refractometer

Page 33: Trenton Sweet Sales Rep

Recommended Boiler Antifreeze

Continuous hot water .8 gpm at 120 degrees F

Century

1 Gallon Boiler Antifreeze

37% Propylene Glycol

Century

1 Quart Boiler Antifreeze

97% Propylene Glycol

Aqua-Hot

Recommends

35%-50%

Propylene Glycol to

Distilled Water Mixture

Page 34: Trenton Sweet Sales Rep

Annual Service Kits

https://secure.aquahot.com/ProductInfo/MSE-ASK-GRN.aspx

Everything you need for an Annual Service

Page 35: Trenton Sweet Sales Rep

Annual Service Kits

Fuel Filter

Diesel Nozzle

Electrode Adjustment

Tool

Refractometer

Burner Gasket

Century

1 Quart Boiler Antifreeze

97% Propylene Glycol

Page 36: Trenton Sweet Sales Rep

QUESTIONS?