thong so ky thuat dan lanh fxmq + lo mo tran

5
Dimensions ED34-862 248 FXMQ-P 3. Dimensions FXMQ20P / 25P / 32PVE Unit (mm) 8 2 × 65=130 3 × 150=450 2 × 150=300 22-φ 4.7 hole 10-8 × 12 oblong hole 9 10 16-φ 4.7 hole 7 4 11 12-8 × 12 oblong hole 6 5 2 1 3 12 40 550 (467 or less) Adjustable (Note. 4) 28 300 144 4 × 65=260 169 588 (Suspention bolt position) 700 or less 290 View 59 60 (All around) 2500 or more (A case without the ceiling) 300 or more (From the Air outlet) 631 or less 200 6 × 65=390 212 232 700 or more (Service space) 700 (Suspention bolt position) 450 or more (Service space) 3 × 65=195 167 355 Inspection hatch 450 or more Ceiling Air inlet Air inlet (Note. 2) Air outlet 277 150 475 (All around) 500 288 80 300 or less 247 150 Air outlet Floor surface 245 150 310 165 210 49 335 215 (All around) 27 (From the Air inlet) (All around) CASE 2), 3) 20 Ceiling Inspection hatch or more B Control box View B-2 Control box Control box Inspection hatch 1 (450mm × 450mm) or less 200 CASE 1) Control box Ceiling Inspection hatch Fig. A 850 or more 700 Inspection hatch 3 (SAME AS THE INDOOR UNIT SIZE +300 OR MORE) View B-1 Control box Inspection hatch 1 (450mm × 450mm) or more 700 or less 550 200 or more (SAME AS THE INDOOR UNIT SIZE OR MORE) Inspection hatch 2 or more Unit base Air outlet Air inlet or more 300 Notes) 1. Location of MANUFACTURE'S LABEL: Control box surface 2. Mount the air filter at the suction side. Select its colorimethod (gravity method) 50% or more. 3. Do not locate things should not be wet under the indoor unit. Dews may drop when humidity reaches over 80%, or a drain gets stuck, or air filters are not clean. 4. Space for Service Works 1) One inspection hatch (450 × 450) on the control box side and a space of 300mm or more under the unit. (Fig. A) 2) One inspection hatch (450 × 450) on the control box side and 2 (two) inspection hatches under the unit. (Arrow View B-1) 3) 3 (three) inspection hatches under the unit and the control box. (Arrow View B-2) According to any one of below 1)~3), secure a space for service works, such as, checking and maintenance of control box and drain pumps, etc. M4 For M10 1 2 3 4 5 6 7 8 9 10 11 12 Socket (For maintenance) REMARK Air suction flange Drain hose (Accessory) PART NAME O. D. φ 32 (Outlet) ITEM Hook φ 12.7 flale connection Interunit wiring connection Power supply connection Liquid pipe connection φ 6.4 flale connection Air discharge flange Control box (Inside) Drain pipe connection Ground terminal (Terminal in Control box) VP25 (O. D. φ 32, I. D. φ 25) VP25 (O. D. φ 32, I. D. φ 25) Gas pipe connection 3D062541A Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Upload: tiger1202

Post on 07-Nov-2014

1.001 views

Category:

Business


0 download

DESCRIPTION

 

TRANSCRIPT

Page 1: Thong so ky thuat dan lanh fxmq + lo mo tran

Dimensions ED34-862

248 FXMQ-P

3. Dimensions

FXMQ20P / 25P / 32PVEUnit (mm)

8

2 × 65=130

3 ×

150

=45

0

2 ×

150=

300

22-φ

4.7

hol

e

10-8

× 1

2 ob

long

hol

e

9

1016

-φ 4

.7 h

ole

74

1112

-8 ×

12

oblo

ng h

ole

65

21

3

12

40

550

(467 or less)Adjustable

(Note. 4)

28

300

144

4 × 65=260

169

588 (Suspention bolt position)

700 or less

290

Vie

w

59

60

(All

arou

nd)

2500 or more(A case withoutthe ceiling)

300 or more

(Fro

m th

e A

ir ou

tlet)

631

or less200

6 × 65=390

212

232

700

or m

ore

(Ser

vice

spa

ce)

700

(Sus

pent

ion

bolt

posi

tion)

450 or more(Service space)

3 × 65=195

167

355

Insp

ectio

n ha

tch

450

or m

ore

Cei

ling

Air

inle

t

Air

inle

t(N

ote.

2)

Air

outle

t

277

150

475

(All

arou

nd)

500

288

80

300

or le

ss

247

150

Air

outle

t

Flo

or s

urfa

ce245

150

310

165

210

49

335

215

(All

arou

nd)

27

(Fro

m th

e A

ir in

let)

(All

arou

nd)

CA

SE

2),

3)

20

Cei

ling

Insp

ectio

n ha

tchor more

BCon

trol

box

Vie

w B

-2

Con

trol

box

Con

trol

box

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

or less200

CA

SE

1) C

ontr

ol b

ox

Cei

ling

Insp

ectio

n ha

tch

Fig

. A

850

or m

ore

700

Insp

ectio

n ha

tch

3(S

AME

AS T

HE IN

DOOR

UNIT

SIZ

E +3

00 O

R M

ORE)

Vie

w B

-1

Con

trol

box

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

or m

ore

700

or less550200

or more

(SA

ME

AS

TH

E IN

DO

OR

UN

IT S

IZE

OR

MO

RE

)

Insp

ectio

n ha

tch

2

or more

Uni

t bas

eA

irou

tlet

Air

inle

t

or more300

Not

es)

1. L

ocat

ion

of M

AN

UF

AC

TU

RE

'S L

AB

EL:

Con

trol

box

sur

face

2. M

ount

the

air

filte

r at

the

suct

ion

side

.S

elec

t its

col

orim

etho

d (g

ravi

ty m

etho

d)50

% o

r m

ore.

3. D

o no

t loc

ate

thin

gs s

houl

d no

t be

wet

un

der

the

indo

or u

nit.

Dew

s m

ay d

rop

whe

n hu

mid

ity r

each

es

over

80%

, or

a dr

ain

gets

stu

ck, o

r ai

r fil

ters

are

not

cle

an.

4. S

pace

for

Ser

vice

Wor

ks

1) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

a s

pace

of 3

00m

m o

r m

ore

unde

r th

e un

it.

(Fig

. A)

2) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

2 (

two)

insp

ectio

n ha

tche

s un

der

the

unit.

(A

rrow

Vie

w B

-1)

3) 3

(th

ree)

insp

ectio

n ha

tche

s un

der

the

unit

and

the

cont

rol b

ox. (

Arr

ow V

iew

B-2

)

Acc

ordi

ng to

any

one

of b

elow

1)~

3), s

ecur

e a

spac

e fo

r se

rvic

e w

orks

, suc

h as

, che

ckin

g an

d m

aint

enan

ce

of c

ontr

ol b

ox a

nd d

rain

pum

ps, e

tc.

M4

For

M10

123456789101112S

ocke

t (F

or m

aint

enan

ce)

RE

MA

RK

Air

suct

ion

flang

e

Dra

in h

ose

(Acc

esso

ry)

PA

RT

NA

ME

O. D

. φ 3

2 (O

utle

t)

ITE

M

Hoo

k

φ 12.

7 fla

le c

onne

ctio

n

Inte

runi

t wiri

ng c

onne

ctio

n

Pow

er s

uppl

y co

nnec

tion

Liqu

id p

ipe

conn

ectio

6.4

flale

con

nect

ion

Air

disc

harg

e fla

nge

Con

trol

box

(In

side

)

Dra

in p

ipe

conn

ectio

n

Gro

und

term

inal

(Ter

min

al in

Con

trol b

ox)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

Gas

pip

e co

nnec

tion

3D06

2541

A

Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Page 2: Thong so ky thuat dan lanh fxmq + lo mo tran

ED34-862 Dimensions

FXMQ-P 249

7

FXMQ40PVEUnit (mm)

3 ×

150

=45

0

12-8

× 1

2 ob

long

hol

e

89

10

74

11

65

21

3

12

14-8

× 1

2 ob

long

hol

e

212

28

300

(All

arou

nd)

(All

arou

nd)

40

or less

650

300 or more

26-φ

4.7

hol

e

485

8 × 65=520

(Sus

pent

ion

bolt

posi

tion)

300

or le

ss

245

631

700

or m

ore

6 × 65=390

165

60

(Note. 4)2500 or more

4 ×

150

=60

0

(Fro

m th

e A

ir ou

tlet)

200

700

700 or less

150

49

(Ser

vice

spa

ce)

167

2 × 65=130

169 29

0

505

363

738 (Suspention bolt position)

144

277

247

450 or more

625

150

(467 or less)

Vie

w

(A case withoutthe ceiling)

Adjustable

460

232

80

(Service space)

59

3 × 65=195

215

150

700

Air

outle

t

Air

outle

t

(All

arou

nd)

Flo

or s

urfa

ce

Air

inle

t28

5

(Fro

m th

e A

ir in

let)

27

Air

inle

t(N

ote.

2)

Cei

ling

(All

arou

nd)

20-φ

4.7

hol

e

Insp

ectio

n ha

tch

450

or m

ore

CA

SE

2),

3)

200

Con

trol

box

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

or less

CA

SE

1)

Vie

w B

-2

Con

trol

box

Insp

ectio

n ha

tch

20

Con

trol

box

Cei

ling

B

or more

Con

trol

box

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

Vie

w B

-1

1000

(SAM

E AS

THE

INDO

ORUN

IT S

IZE

+300

OR

MOR

E)

Insp

ectio

n ha

tch

3

700

or mo

re

Insp

ectio

n ha

tch

Con

trol

box

Cei

ling

Fig

. A

Uni

t bas

eA

irou

tlet

Air

inle

t

300or more

or more

or mo

re70

0

(SA

ME

AS

TH

E IN

DO

OR

UN

IT S

IZE

OR

MO

RE

)

Insp

ectio

n ha

tch

2

or less or more200 700

Not

es)

1. L

ocat

ion

of M

AN

UF

AC

TU

RE

'S L

AB

EL:

Con

trol

box

sur

face

2. M

ount

the

air

filte

r at

the

suct

ion

side

.S

elec

t its

col

orim

etho

d (g

ravi

ty m

etho

d)50

% o

r m

ore.

3. D

o no

t loc

ate

thin

gs s

houl

d no

t be

wet

un

der

the

indo

or u

nit.

Dew

s m

ay d

rop

whe

n hu

mid

ity r

each

es

over

80%

, or

a dr

ain

gets

stu

ck, o

r ai

r fil

ters

are

not

cle

an.

4. S

pace

for

Ser

vice

Wor

ks

1) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

a s

pace

of 3

00m

m o

r m

ore

unde

r th

e un

it.

(Fig

. A)

2) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

2 (

two)

insp

ectio

n ha

tche

s un

der

the

unit.

(A

rrow

Vie

w B

-1)

3) 3

(th

ree)

insp

ectio

n ha

tche

s un

der

the

unit

and

the

cont

rol b

ox. (

Arr

ow V

iew

B-2

)

Acc

ordi

ng to

any

one

of b

elow

1)~

3), s

ecur

e a

spac

e fo

r se

rvic

e w

orks

, suc

h as

, che

ckin

g an

d m

aint

enan

ce

of c

ontr

ol b

ox a

nd d

rain

pum

ps, e

tc.

M4

For

M10

123456789101112S

ocke

t (F

or m

aint

enan

ce)

RE

MA

RK

Air

suct

ion

flang

e

Dra

in h

ose

(Acc

esso

ry)

PA

RT

NA

ME

O. D

. φ 3

2 (O

utle

t)

ITE

M

Hoo

k

φ 12.

7 fla

le c

onne

ctio

n

Inte

runi

t wiri

ng c

onne

ctio

n

Pow

er s

uppl

y co

nnec

tion

Liqu

id p

ipe

conn

ectio

6.4

flale

con

nect

ion

Air

disc

harg

e fla

nge

Con

trol

box

(In

side

)

Dra

in p

ipe

conn

ectio

n

Gro

und

term

inal

(Ter

min

al in

Con

trol b

ox)

VP25

(O. D

. φ 3

2, I. D

. φ 2

5)

VP25

(O. D

. φ 3

2, I. D

. φ 2

5)

Gas

pip

e co

nnec

tion

3D06

0160

E

Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Page 3: Thong so ky thuat dan lanh fxmq + lo mo tran

Dimensions ED34-862

250 FXMQ-P

FXMQ50PVEUnit (mm)

49

M4

For

M10

5 ×

150

=75

0

16-8

× 1

2 ob

long

hol

e

18-8

× 1

2 ob

long

hol

e

30-φ

4.7

hol

e

74

11

65

21

3

12

9

8

10

123456789101112

(467 or less)

1000

60

(A case withoutthe ceiling)

Soc

ket (

For

mai

nten

ance

)

513

13 × 65=845

RE

MA

RK

Air

suct

ion

flang

e

277

925

Dra

in h

ose

(Acc

esso

ry)

(Ser

vice

spa

ce)

700

or m

ore

27 (Service space)

40

PA

RT

NA

ME

245

or less

O. D

. φ 3

2 (O

utle

t)

950

150

167

ITE

M

631

785

Hoo

k

φ 12.

7 fla

le c

onne

ctio

n

Inte

runi

t wiri

ng c

onne

ctio

n

Pow

er s

uppl

y co

nnec

tion

Liqu

id p

ipe

conn

ectio

6.4

flale

con

nect

ion

450 or more

247

Air

disc

harg

e fla

nge

(Sus

pent

ion

bolt

posi

tion)

290

(All

arou

nd)

232

Con

trol

box

(In

side

)

1038 (Suspention bolt position)

Adjustable

144

300 or more

28

200

150

212

Dra

in p

ipe

conn

ectio

n

Gro

und

term

inal

(Ter

min

al in

Con

trol b

ox)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

(All

arou

nd)

80

150

(Note. 4)

300

Vie

w

(All

arou

nd)

300

or le

ss

700 or less

169

6 ×

150

=90

0

165

805

VP25

(O. D

. φ 32

, I. D

. φ 25

)

760

(Fro

m th

e A

ir ou

tlet)

11 × 65=715

59

3 × 65=195

215

700

2 × 65=130

Gas

pip

e co

nnec

tion

Flo

or s

urfa

ce

435

(All

arou

nd)

Cei

ling

36-φ

4.7

hol

e

Insp

ectio

n ha

tch

450

or m

ore

Air

inle

t(N

ote.

2)

Air

outle

t

Air

outle

tA

ir in

let

(Fro

m th

e A

ir in

let)

CA

SE

1)

Con

trol

box

200

Insp

ectio

n ha

tch

1 (4

50m

m ×

450

mm

)

or less

Vie

w B

-2

Con

trol

box

CA

SE

2),

3)

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

Con

trol

box

Vie

w B

-1

20

Con

trol

box

B

or more

Cei

ling

Insp

ectio

n ha

tch

1300

(SAM

E AS

THE

INDO

ORUN

IT S

IZE

+300

OR

MOR

E)

Insp

ectio

n ha

tch

3

700

or mo

re

Fig

. A

Insp

ectio

n ha

tch

Cei

ling

Con

trol

box

or more300

Uni

t bas

eA

irin

let

Air

outle

t

or more

or mo

re70

0In

spec

tion

hatc

h 2

(SA

ME

AS

TH

E IN

DO

OR

UN

IT S

IZE

OR

MO

RE

)

200or moreor less

1000

Not

es)

1. L

ocat

ion

of M

AN

UF

AC

TU

RE

'S L

AB

EL:

Con

trol

box

sur

face

2. M

ount

the

air

filte

r at

the

suct

ion

side

.S

elec

t its

col

orim

etho

d (g

ravi

ty m

etho

d)50

% o

r m

ore.

3. D

o no

t loc

ate

thin

gs s

houl

d no

t be

wet

un

der

the

indo

or u

nit.

Dew

s m

ay d

rop

whe

n hu

mid

ity r

each

es

over

80%

, or

a dr

ain

gets

stu

ck, o

r ai

r fil

ters

are

not

cle

an.

4. S

pace

for

Ser

vice

Wor

ks

1) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

a s

pace

of 3

00m

m o

r m

ore

unde

r th

e un

it.

(Fig

. A)

2) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

2 (

two)

insp

ectio

n ha

tche

s un

der

the

unit.

(A

rrow

Vie

w B

-1)

3) 3

(th

ree)

insp

ectio

n ha

tche

s un

der

the

unit

and

the

cont

rol b

ox. (

Arr

ow V

iew

B-2

)

Acc

ordi

ng to

any

one

of b

elow

1)~

3), s

ecur

e a

spac

e fo

r se

rvic

e w

orks

, suc

h as

, che

ckin

g an

d m

aint

enan

ce

of c

ontr

ol b

ox a

nd d

rain

pum

ps, e

tc.

2500 or more

3D06

0159

D

Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Page 4: Thong so ky thuat dan lanh fxmq + lo mo tran

ED34-862 Dimensions

FXMQ-P 251

7

FXMQ63P / 80PVEUnit (mm)

6 ×

150

=90

0

513

18-8

× 1

2 ob

long

hol

e

16-8

× 1

2 ob

long

hol

e

36-φ

4.7

hol

e

30-φ

4.7

hol

e

9

8

10

74

11

65

13

12

2829

0

(All

arou

nd)

2763

1

1038 (Suspention bolt position)212

150

700

300

or le

ss

80

3001000

150

2500 or more(A case withoutthe ceiling)

805

950

5 ×

150

=75

0

785

760

2

169

40

Vie

w

925

49

277

232

300 or more

(All

arou

nd)

(Note. 4)

150

247

11 × 65=715

3 × 65=195

(Ser

vice

spa

ce)

700

or m

ore

(Fro

m th

e A

ir ou

tlet)

(All

arou

nd)

165

13 × 65=845

700 or less

2 × 65=130

65

59

167

215

245

200or less

(Sus

pent

ion

bolt

posi

tion)

144

(467 or less)Adjustable

Air

inle

t(N

ote.

2)

Air

outle

t

Flo

or s

urfa

ce

Insp

ectio

n ha

tch

450

or m

ore

Air

inle

t

(All

arou

nd)

(Fro

m th

e A

ir in

let)

Cei

ling

435

Air

outle

t

Vie

w B

-1

Con

trol

box

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

or less

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

200

Con

trol

box

CA

SE

1)

Insp

ectio

n ha

tch

Cei

ling

Con

trol

box

Fig

. A

Vie

w B

-2

Con

trol

box

CA

SE

2),

3)

or m

ore

700

or more

or more

1000200or less

Insp

ectio

n ha

tch

2(S

AM

E A

S T

HE

IND

OO

RU

NIT

SIZ

E O

R M

OR

E)

B

20

Cei

ling

Con

trol

box

Insp

ectio

n ha

tch

(SAM

E AS

THE

INDO

ORUN

IT S

IZE

+300

OR

MOR

E)

Insp

ectio

n ha

tch

3

1300

700

or m

ore

Air

outle

tA

irin

let

Uni

t bas

e

or more300

(Service space)450 or more

or more

Not

es)

1. L

ocat

ion

of M

AN

UF

AC

TU

RE

'S L

AB

EL:

Con

trol

box

sur

face

2. M

ount

the

air

filte

r at

the

suct

ion

side

.S

elec

t its

col

orim

etho

d (g

ravi

ty m

etho

d)50

% o

r m

ore.

3. D

o no

t loc

ate

thin

gs s

houl

d no

t be

wet

un

der

the

indo

or u

nit.

Dew

s m

ay d

rop

whe

n hu

mid

ity r

each

es

over

80%

, or

a dr

ain

gets

stu

ck, o

r ai

r fil

ters

are

not

cle

an.

4. S

pace

for

Ser

vice

Wor

ks

1) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

a s

pace

of 3

00m

m o

r m

ore

unde

r th

e un

it.

(Fig

. A)

2) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

2 (

two)

insp

ectio

n ha

tche

s un

der

the

unit.

(A

rrow

Vie

w B

-1)

3) 3

(th

ree)

insp

ectio

n ha

tche

s un

der

the

unit

and

the

cont

rol b

ox. (

Arr

ow V

iew

B-2

)

Acc

ordi

ng to

any

one

of b

elow

1)~

3), s

ecur

e a

spac

e fo

r se

rvic

e w

orks

, suc

h as

, che

ckin

g an

d m

aint

enan

ce

of c

ontr

ol b

ox a

nd d

rain

pum

ps, e

tc.

M4

For

M10

123456789101112S

ocke

t (F

or m

aint

enan

ce)

RE

MA

RK

Air

suct

ion

flang

e

Dra

in h

ose

(Acc

esso

ry)

PA

RT

NA

ME

O. D

. φ 3

2 (O

utle

t)

ITE

M

Hoo

k

φ 15.

9 fla

le c

onne

ctio

n

Inte

runi

t wiri

ng c

onne

ctio

n

Pow

er s

uppl

y co

nnec

tion

Liqu

id p

ipe

conn

ectio

9.5

flale

con

nect

ion

Air

disc

harg

e fla

nge

Con

trol

box

(In

side

)

Dra

in p

ipe

conn

ectio

n

Gro

und

term

inal

(Ter

min

al in

Con

trol b

ox)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

Gas

pip

e co

nnec

tion

3D06

0161

E

Please purchase PDF Split-Merge on www.verypdf.com to remove this watermark.

Page 5: Thong so ky thuat dan lanh fxmq + lo mo tran

Dimensions ED34-862

252 FXMQ-P

FXMQ100P / 125PVEUnit (mm)

20-8

× 1

2 ob

long

hol

e

20-8

× 1

2 ob

long

hol

e9

8

10

74

11

65

21

3

12

8 ×

150

=12

00

713

1400

2 × 65=130

212

1205

300 or more

2500 or more

(All

arou

nd)

Vie

w

40

169

700

59

(Fro

m th

e A

ir ou

tlet)

165

1325

(All

arou

nd)

1350

290

232(467 or less)Adjustable

65

150

28

7 ×

150

=10

50

19 × 65=1235

49150

1438 (Suspention bolt position)

245

277

300

or le

ss

144

700

or m

ore

(Ser

vice

spa

ce)

700 or more27

80

150

or less200

215

631

(Sus

pent

ion

bolt

posi

tion)

167

(Note. 4)

(Service space)450 or more16 × 65=1040

1185

1160

3 × 65=195

247

(SA

ME

AS

TH

E IN

DO

OR

UN

IT S

IZE

OR

MO

RE

)

(All

arou

nd)

300

(A case withoutthe ceiling)

Flo

or s

urfa

ce

Air

outle

t

(All

arou

nd)

Air

outle

t

(Not

e.2)

Air

inle

t

635

48-φ

4.7

hol

e

Cei

ling

Air

inle

t

Vie

w B

-1

Con

trol

box

or less

Con

trol

box

or m

ore

200

700

1400or more

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)

Insp

ectio

n ha

tch

450

or m

ore

Fig

. A

or less Uni

t bas

e

200

Insp

ectio

n ha

tch

1(4

50m

m ×

450

mm

)C

ontr

ol b

ox

Air

outle

tA

irin

let

CA

SE

1) C

ontr

ol b

ox

Insp

ectio

n ha

tch

or more

Cei

ling

Insp

ectio

n ha

tch

2(S

AM

E A

S T

HE

IND

OO

RU

NIT

SIZ

E O

R M

OR

E)

or more1700

or m

ore

700

Vie

w B

-2

Insp

ectio

n ha

tch

3(S

AME A

S THE

INDO

ORUN

IT SIZ

E +30

0 OR

MORE

)

CA

SE

2),

3)

Cei

ling

B

Insp

ectio

n ha

tch

20or more

Con

trol

box

300

(Fro

m th

e A

ir in

let)

40-φ

4.7

hol

e

Not

es)

1. L

ocat

ion

of M

AN

UF

AC

TU

RE

'S L

AB

EL:

Con

trol

box

sur

face

2. M

ount

the

air

filte

r at

the

suct

ion

side

.S

elec

t its

col

orim

etho

d (g

ravi

ty m

etho

d)50

% o

r m

ore.

3. D

o no

t loc

ate

thin

gs s

houl

d no

t be

wet

un

der

the

indo

or u

nit.

Dew

s m

ay d

rop

whe

n hu

mid

ity r

each

es

over

80%

, or

a dr

ain

gets

stu

ck, o

r ai

r fil

ters

are

not

cle

an.

4. S

pace

for

Ser

vice

Wor

ks

1) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

a s

pace

of 3

00m

m o

r m

ore

unde

r th

e un

it.

(Fig

. A)

2) O

ne in

spec

tion

hatc

h (4

50 ×

450

) on

the

cont

rol b

ox

side

and

2 (

two)

insp

ectio

n ha

tche

s un

der

the

unit.

(A

rrow

Vie

w B

-1)

3) 3

(th

ree)

insp

ectio

n ha

tche

s un

der

the

unit

and

the

cont

rol b

ox. (

Arr

ow V

iew

B-2

)

Acc

ordi

ng to

any

one

of b

elow

1)~

3), s

ecur

e a

spac

e fo

r se

rvic

e w

orks

, suc

h as

, che

ckin

g an

d m

aint

enan

ce

of c

ontr

ol b

ox a

nd d

rain

pum

ps, e

tc.

M4

For

M10

123456789101112S

ocke

t (F

or m

aint

enan

ce)

RE

MA

RK

Air

suct

ion

flang

e

Dra

in h

ose

(Acc

esso

ry)

PA

RT

NA

ME

O. D

. φ 3

2 (O

utle

t)

ITE

M

Hoo

k

φ 15.

9 fla

le c

onne

ctio

n

Inte

runi

t wiri

ng c

onne

ctio

n

Pow

er s

uppl

y co

nnec

tion

Liqu

id p

ipe

conn

ectio

9.5

flale

con

nect

ion

Air

disc

harg

e fla

nge

Con

trol

box

(In

side

)

Dra

in p

ipe

conn

ectio

n

Grou

nd te

rmina

l (Te

rmina

l in C

ontro

l box

)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

VP25

(O. D

. φ 32

, I. D

. φ 25

)

Gas

pip

e co

nnec

tion

3D06

0162

D