the ultimate co 2 refrigeration system for every food retail store format
DESCRIPTION
The Ultimate CO 2 Refrigeration System for every food retail store format. Market developments in Commercial Refrigeration RAC Question Time November 29th 2011, London Speakers: Christoph Brouwers . MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATION T he last two decades. - PowerPoint PPT PresentationTRANSCRIPT
Market developments in Commercial Refrigeration
RAC Question Time November 29th 2011, London
Speakers: Christoph Brouwers
The Ultimate CO2 Refrigeration System for every
food retail store format
2
MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATIONThe last two decades
Significant GWP of HFC refrigerants demanded efforts to reduce the greenhouse gas effect resulting from these substances
refrigerant charges reduced
system tightness improved
Situation better but no real long term way forward
numerous supermarket refrigeration systems with different natural refrigerants, some with secondary refrigerant- / waste heat circuit, realised
3
climate protection: EU F-gas regulation, national regulations
economic aspects: Raising energy and F-gas cost
energy efficiency: EU legislation (ErP) coming into play
MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATION
Market drivers
4
Based on collected experiences CO2 DX emerged as state of the art solution in food retail stores today
MARKET DEVELOPMENTS IN COMMERCIAL REFRIGERATION
0
50
100
150
200
250
300
350
400
2004 2005 2006 2007 2008 2009 2010 2011 LE
STORES IN OPERATIONOctober 2011
Denmark (43)
Switzerland (72)
Germany (137)
Luxembourg (1)
Austria (2)
United Kingdom (6)
Norway (16)
Netherlands (8)
Sweden (9)
Czech Republic (10)
Poland (2)
First CO2OLtec Installation in Switzerland in 2004
Finnland (2)
Slovakia (2)
Italy (1)
YTD October 2011313 Stores in operation (181 YTD PY)34,6 MW MT capacity (21,5 MW PY)4,5 million operating hours (509 Years)
Pilot Stores SeriesHungary (2)
R404A CO2
166.000
84.700
-49%
CO2 equivalent(tons) Cumulated reduction of CO2 emissions
81.300 tons or*
24.100 X
Environmental Impact
* Average car using 0,12Kg CO2/km; run time 15.000 km per year
STORES IN OPERATIONOctober 2011
Denmark (43)
Switzerland (72)
Germany (137)
Luxembourg (1)
Austria (2)
United Kingdom (6)
Norway (16)
Hungary (2)
Netherlands (8)
Sweden (9)
Czech Republic (10)
Poland (2)
Finnland (2)
Slovakia (2)
Italy (1)
YTD October 2011313 Stores in operation (181 YTD PY)34,6 MW MT capacity (21,5 MW PY)4,5 million operating hours (509 Years)
CO2 DX-REFRIGERATING SYSTEMSGeography
Lyon 12°C
Berlin 9°C
Barcelona 15°C
Madrid 14°C
Marseille
14°C
Milano 13°C
Rom 16°C
Budapest 11°C
Athen 18°C
Prag 8°C
Porto 14°C
Valencia 17°C
Florenz 15°C
Tirana 16°C
Belgrad 12°C
Thessaloniki 16°C
Triest 14°C
Bordeaux 12°C
Málaga 18°C
Sofia 11°C
Oslo 5°CCO2 DX systems today
Attractive energy performance at average annual temperatures up to +15 °C in line with EPEE statement and energy data recording
Lyon 12°C
Berlin 9°C
Barcelona 15°C
Madrid 14°C
Marseille
14°C
Milano 13°C
Rom 16°C
Budapest 11°C
Athen 18°C
Prag 8°C
Porto 14°C
Valencia 17°C
Florenz 15°C
Tirana 16°C
Belgrad 12°C
Thessaloniki 16°C
Triest 14°C
Bordeaux 12°C
Málaga 18°C
Sofia 11°C
Oslo 5°CCO2 DX systems today
CO2 DX-REFRIGERATING SYSTEMSGeography
Attractive energy performance at average annual temperatures up to +15 °C in line with EPEE statement and energy data recording
Lyon 12°C
Berlin 9°C
Barcelona 15°C
Madrid 14°C
Marseille
14°C
Milano 13°C
Rom 16°C
Budapest 11°C
Athen 18°C
Prag 8°C
Porto 14°C
Valencia 17°C
Florenz 15°C
Tirana 16°C
Belgrad 12°C
Thessaloniki 16°C
Triest 14°C
Bordeaux 12°C
Málaga 18°C
Sofia 11°C
Oslo 5°C
CO2 DX systems next
generation
CO2 DX-REFRIGERATING SYSTEMSGeography
Attractive energy performance across Europe
Company restricted information 10
Thank you for your attention!
Carrier has the right refrigerant for every application, but every application will not have the same refrigerant solution.