the texas wake up and breathe quality improvement initiative: data collection activities terri...

34
The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake Up and Breathe Initiative 1

Upload: sharleen-french

Post on 27-Dec-2015

221 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

The TEXAS Wake Up and Breathe Quality Improvement Initiative:

Data Collection Activities

Terri Conner, PhDNybeck AnalyticsProject Manager Texas Wake Up and Breathe Initiative

1

Page 2: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Overall Initiative Purpose

Improve care for ventilated patients

– Improve sedative weaning

– Speed extubation

2

Page 3: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Results of Observation Studies

Audits from across the country show that Spontaneous awakening trials (SATs) and

Spontaneous breathing trials (SBTs) are only initiated 50% of the time

SBTs not coordinated with SATs

3

Page 4: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Benefits of coupled SATs and SBTs

time on ventilation up to 3 days time in hospital up to 4 days

4

Page 5: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Texas Wake Up and Breathe Collaborative Structure

Designate champion

Baseline survey

– Please complete this at your earliest convenience and

return to Terri Conner at [email protected]

Monthly data submission and surveys

Monthly calls with our group

5

Page 6: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Three tools

Monthly survey Daily data collection tool Monthly data submission

Page 7: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Monthly SurveyAll Teach, All Learn

Aim

Tests conducted

Outcomes

Lessons learned

Barriers / breakthroughs

Plans for next month

7

Page 8: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Data Collection Efforts

Track performance Measure impact on outcomes

– LOS– Mortality– Antibiotic usage– VAC, IVAC, VAP rates

8

Page 9: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

SAT/SBT Performance Documentation

Clinical champions should oversee SAT/SBT documentation

Integrate into existing processes– Daily care plans– Checklists

Develop your own process

9

Page 10: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data Elements

Excel spreadsheet tool Automatic calculation

– VAC– IVAC

Possible and probable VAP

10

Page 11: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Outcome Definitions

VAC– Significant respiratory deterioration after >2 days

of stability

IVAC– VAC– abnormal temp or WBC count– >4 days of new antibiotics

11

Page 12: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Outcome Definitions

Possible VAP– IVAC– Either purulent sputum OR + sputum/BAL culture

Probable VAP– IVAC– Both purulent sputum AND + sputum/BAL culture

12

Page 13: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionVAC Status

Patient Date PEEPmin FiO2min VAC

1 1-Apr-12 10 100

1 2-Apr-12 5 60

1 3-Apr-12 5 40

1 4-Apr-12 8 50

13

Page 14: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionVAC Status

Patient Date PEEPmin FiO2min VAC

1 1-Apr-12 10 100

1 2-Apr-12 5 60

1 3-Apr-12 9 50 VAC

14

Page 15: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionIVAC Status

Tmin, Tmax, WBCmin, WBCmax

– Enter for a total of 5 days

– Start 2 days prior to VAC onset

15

Page 16: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionIVAC Status

Pt Date Tmin

Tmax

WBCmin

WBCmax

QAD SigTemp

SigWBC

QADFlag

IVAC

1 1-Apr 37 37.5 6 8

1 2-Apr 37.5 37.8 6 8

1 3-Apr 37 38.3 6 14

1 4-Apr

1 5-Apr

16

Page 17: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionIVAC Status

Pt Date Tmin

Tmax

WBCmin

WBCmax

QAD SigTemp

SigWBC

QADFlag

1 3-Apr

37 38.3 6 14 Yes

17

Page 18: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionQAD Determination

QAD

– New antibiotic prescribed or continued– Includes days between doses at extended

intervals (> q 24 h)– Data are entered for up 10 days (4 days before

VAC, on the VAC dx day, and 5 days after VAC)

18

Page 19: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Antibiotic WorksheetQAD Determination

Dose hour

-4 -3 -2 -1 VAC day 0

1 2 3 4 5

Levo 24 Y Y

Vanc Y Y

Vanclevel

Y

19

Page 20: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Antibiotic WorksheetQAD Determination

Pt Dose hour

-4 -3 -2 -1 VAC day

0

1 2 3 4 5

Levo 24 Y Y

Vanc Y Y Y

Vanclevel

Y

QAD X X X X X X X

20

Page 21: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionIVAC Status

Pt Tmin

Tmax

WBCmin

WBCmax

QAD SigTemp

SigWBC

QADFlag

IVAC

1 37 38.3 6 14 Yes 1 1 3 IVAC

21

Page 22: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Enter sputum/BAL gram stain and culture results

– Polys

– Epis

– Culture

– Growth > Threshold

22

Page 23: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Patient Date Polys Epis Culture Growth > Threshold

1 1-Apr-12 3 1

1 2-Apr-12 2 2 Enterococcus

1 3-Apr-12 2 1 Klebsiella Yes

23

Page 24: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

POLYS– Sputum or BAL gram stain polymorphonucleated

cells, neutrophils, or white blood cells– Enter 0 to 4

0: none 1: few, rare, <10 cells/lpf 2: moderate, >25 cells/lpf 3: many 4: abundant

24

Page 25: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

EPIS– Sputum or BAL gram stain epithelial cells or

squamous cells– Enter 0 to 4

0: none 1: few, rare, <10 cells/lpf 2: moderate, >25 cells/lpf 3: many 4: abundant

25

Page 26: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Patient Date Polys Epis Culture Growth > Threshold

1 1-Apr-12 3 1

1 2-Apr-12 2 2 Enterococcus

1 3-Apr-12 2 1 Klebsiella Yes

26

Page 27: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Patient Date Polys Epis Culture Growth > Threshold

1 1-Apr-12 3 1

1 2-Apr-12 2 2

1 3-Apr-12 2 1

27

Page 28: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

CULTURE– Enter the culture result

Growth > Threshold– Yes

> 105 CFU/mL for endotracheal aspirate > 104 CFU/mL for BAL > 103 CFU/mL for protected specimen brush Semi-quantitative equivalents also acceptable

28

Page 29: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Patient Date Polys Epis Culture Growth > Threshold

1 1-Apr-12 3 1

1 2-Apr-12 2 2 Enterococcus

1 3-Apr-12 2 1 Klebsiella Yes

29

Page 30: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Patient Date Polys Epis Culture Growth > Threshold

1 1-Apr-12 3 1

1 2-Apr-12 2 2 Enterococcus

1 3-Apr-12 2 1 Klebsiella Yes

30

Page 31: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Daily Data CollectionPossible/Probable VAP Status

Patient Date Possible VAP

Probable VAP

Final Determination

1 1-Apr-12

1 2-Apr-12

1 3-Apr-12 Probable VAP

Probable VAP

31

Page 32: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Monthly Data Report

Hospital LOS ICU LOS Hospital discharge status Ventilator days SAT days – ‘real time’ data collection SBT days - ‘real time’ data collection Self-extubated / re-intubated (optional) Outcomes (VAC,IVAC, poss/prob VAP)

32

Page 33: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Monthly Data Report

33

Main Street Hospital 1 20 8 A 5 4 2 n n y y y nMain Street Hospital 2 6 4 A 4 4 2 n n n n n nMain Street Hospital 3 13 9 A 7 6 6 n n y y n n

VAP -Possible

VAP -Probable

SAT days

SBT days

Self-Extubated (optional)

Re-Intubated (optional)

VAC IVACHosp

Discharge Status

Vent Days

Hospital IDPt

NumberHosp LOS

ICU LOS

Page 34: The TEXAS Wake Up and Breathe Quality Improvement Initiative: Data Collection Activities Terri Conner, PhD Nybeck Analytics Project Manager Texas Wake

Questions?

Repeat webinar on July 16th, 9am CT Please feel free to contact Terri at

[email protected] or Rachel at [email protected]

34