the inclined plane (ip) – a helpful non-compliance device (a case presentation)

13
Dr. Noeke, Meschede, Germany 2012 The Inclined Plane (IP) – a helpful non-compliance device (a case presentation) American Association of Orthodontists 112th Annual Session Honolulu, Hawaii – May 4-8, 2012

Upload: ghada

Post on 09-Feb-2016

27 views

Category:

Documents


0 download

DESCRIPTION

American Association of Orthodontists 112th Annual Session Honolulu, Hawaii – May 4-8, 2012. The Inclined Plane (IP) – a helpful non-compliance device (a case presentation). American Association of Orthodontists 112th Annual Session Honolulu, Hawaii – May 4-8, 2012. Authors: - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

The Inclined Plane (IP) – a helpful non-compliance device

(a case presentation)

American Association of Orthodontists 112th Annual Session Honolulu, Hawaii –

May 4-8, 2012

Page 2: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Authors:

Raphael Hoehr

Werner Noeke – private office, Meschede, Germany

Tim Noeke – University of Muenster, Germany

Kathrin Weyer – University of Frankfurt, Germany

American Association of Orthodontists 112th Annual Session Honolulu, Hawaii –

May 4-8, 2012

Page 3: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Purpose:

Persistency of deciduous upper incisors or primary shortage of space can lead to an reclination of permanent teeth or to pseudoprognathism with a class III relationship of the front teeth.

14.09.2011 14.09.2011 14.09.2011

Page 4: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Patient:

Fabian S., 7 years, reclination of 11, pseudoprognathism

30.05.2011 30.05.2011 30.05.2011

Page 5: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Material/Methods:

The acrylic inclined plane is easy to produce and fixed on the lower incisors with GIC as a semi-permanent non-compliance device. The retrusive and inclined upper incisor gets in contact to the IP when the patient starts the chewing process and slides down and forward. The angle of the inclined plane should be about 65° - 75 ° to the occlusal plane. Due to the protrusion of the incisor, the upper edge of the plane has to be adjusted when it gets in contact to the palatal tissue.

14.09.201114.09.2011 14.09.2011

Page 6: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

14 days after incooperation, tooth 11 is unlocked.

28.09.2011 28.09.2011

28.09.2011

Page 7: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Directly after removing the inclined plane.

28.09.2011 28.09.2011

28.09.2011

Page 8: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

For retention a removable retainer with protrusion springs for the upper incisors and Eschler-arch for the lower incisors is used.

06.10.2011 06.10.2011

06.10.2011

Page 9: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

4 months later: The result has improved.

30.01.2012

30.01.2012 30.01.2012

Page 10: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Results:

Generally a malocclusion is unlocked in an average treatment time of 1-3 weeks. In this case the treatment time was 14 days and there was e.g. a significant change of SNA, upper incisor-angle and upper lip profile.

For retention a removable retainer with protrusion springs for the upper incisors and Eschler-arch for the lower incisors is used.

30.01.1214.09.11 14.09.11

Page 11: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Initial findings Final findings

30.05.11 30.01.12 Norm

SNA 79.8° 81.4° 82°Facial Convexity 1.9 mm 2.7 mm 2 mmInterizisalwinkel 145.6° 133.4° 130°OK 1er/ SPP 93.2° 106° 109°

30.05.11 30.01.12 Upper lip profile has improved

Page 12: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

Conclusion:

These malocclusions can be corrected speedily in an easy way. Using the IP in early treatment is a very save, quick, cheap, robust and intermediate device without any wires, braces or occlusal bite-planes. The IP causes no trauma and is usually well accepted by the young patient.

30.01.2012 30.01.2012 30.01.2012

Page 13: The Inclined Plane (IP) – a helpful non-compliance device (a case presentation)

Dr. Noeke, Meschede, Germany 2012

For more Information:

Werner Noeke, Raphael HoehrOesterweg 5

59872 Meschede, Germanyphone: +49 291 7098

www.drwernernoeke.dee-mail: [email protected]

This presentation is kindly supported by:

Scheu Dental, Iserlohn Germany, www.scheu-dental.comKaniedenta, Herford Germany, www.kaniedenta.de