THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 [email protected] The Guardian is the only IP66 rated 4 way outdoor power board of its size available in Australia Designed & tested for construction sites H Class Complies to AS/NZ 3190, 3112 & 3012 Sale for indoor & outdoor use

Upload: others

Post on 12-Jun-2020

11 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

THE GUARDIAN OUTDOOR POWER BOARD

User Guide

1800 338 [email protected]

The Guardian is the only IP66 rated 4 way outdoor power board of its size available in Australia

• Designed & tested for construction sites• H Class• Complies to AS/NZ 3190, 3112 & 3012• Sale for indoor & outdoor use

Page 2: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Introduction

Congratulations on your purchase of a Guardian RCD protected portable

power outlet board. These units offer unsurpassed protection against

electric shock and overload in a wide range of applications.

The unit has been built tough for use by professional tradesmen who are

working in the field; or in the workshop.

This portable outlet board has been designed specifically with safety in

mind by utilizing AUTOSWITCHED outlets. These double pole outlets

allow power onto the plug only after the plug is inserted.

RCD/MCB (RCBO) – This device is a combination MCB and RCD. The

MCB protects against electrical overload. Should the connected load

exceed the maximum current operation of the MCB, the MCB will trip.

The RCD protects against electrocution or electrical shorts from active

circuits to earth.

• 1 x 10kA RCDBO per unit

• IP66 rated

• Class H compliant device

• Lockable RCD cover

• Press to TEST RCBO button

• Built tough to survive harsh working environments

• Status flags to show RCBO trip condition

• Auto switched outlets for added safety

(Outlets will not switch on until a plug is inserted)

Page 3: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Operating Instructions:

1. Fully uncoil the lead

2. Plug the unit into a mains connected socket outlet and turn on the

power switch at the socket

3. Undo the clear plastic window retaining screw, lift the cover and

switch the unit on by operating the toggle switch.

4. TEST THE RCBO before each and every use by depressing the

test button. This will immediately cause the unit to trip and shut off

the power to the socket outlets. If the RCBO fails to switch OFF

after depressing the test button then the unit should be immediately

taken out of service, tagged appropriately and not be used until

repaired by a qualified electrician or returned to Powersafe for

repairs.

5. Reset the toggle switch to the on position.

6. Repeat the process for the second RCBO fitted to the unit.

7. The unit is now ready for operation. Plug in your 240 volt appliance

and use as per the manufacturers operating instructions. No

electrical device should be operated or plugged in prior to checking

for physical damage and testing of the RCBO.

IMPORTANT

If this portable appliance is used in weather conditions (i.e. rain) then to ensure it

retains its IP rating, only use leads or appliances fitted with IP66 or similar type

plugs to maintain the IP rating required.

IP rated plugs are easily recognized by the screw thread on the plug which will

thread on the socket forming a seal against dust and water entry.

IP rated plugs are not required for operation, but if they are not used then the

unit does not maintain its IP rating and should not be used in adverse conditions

and only used where weather, water or dust will not cause failure to the unit and

or the possibility of electrocution.

Using the power board in adverse conditions, causing damage to the outlet due

to water or dust entry will void the warranty of the product.

Page 4: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Important Notes:

• In some applications this unit may require regular testing and tagging

to be compliant with state or national codes. Ensure you are familiar

with the regulations regarding uses of PSOA and if required, have

the unit regularly tested to ensure compliance. This is the

responsibility of the owner and/or user.

• Electricity is dangerous and the use of this product cannot be

regarded as a substitute for basic electrical safety precautions.

Ensuring the use of this product is within local or national electrical

codes is the responsibility of the owner and/or user.

• Unplug any equipment from power prior to inspection or repair.

• If the unit continually trips, or if trips at any time, you may be

operating a faulty appliance. Your appliance should be inspected by

a qualified electrician.

• A portable power outlet should never be plugged into a extension

lead (socket end). The unit should only be plugged into a power

outlet (power point) only. Extension leads (plug end) can then be run

from the portable power outlet.

• Do not use the product in flammable area.

• Do not use or store the equipment in adverse conditions.

• Do not immerse the product in water or liquids.

• Do not allow the product to come into contact with petroleum

products, alkaline detergents, industrial cleaners or any product that

can cause damage to the unit.

• Storage and use in adverse conditions may effect performance.

• Use of IP rated plugs is strongly recommended for prevention of dust

or moisture ingress of the unit.

• Test the operation of each RCBO before each and every use by

pressing the “Test” button. Failure to trip the RCBO requires the unit

to be repaired prior to use.

• Visually inspect the unit prior to every use. If there is any damage to

the unit then the unit should be taken out of operation until corrected.

Page 5: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Technical Specifications:

AUSTRALIAN APPROVAL NUMBER TO AS/NZS 3190: TUV15056EA

Operating Voltage 230 – 240 – AC – 50 HZ

Operating temperature

range-10◦c to + 60◦c (celsius)

Protective Device RCB / MCB (RCBO combination)

MCB tripping

characteristic10 or 15 amp

Plug type IP66 3 pin Australian Standard 10 amp

RCD tripping

characteristic

30mA C10 or C16A

C Curve

Socket outlet type Double Pole Autoswitched Outlet – 10 or 15 amp

Socket model Powersafe PSASo-10 or PSASO-15

Lead type 2.5mm heavy duty flex, earth screened

Lead length 1.75 m

International

Protective RangeIP66

Class Class H (suitable for construction sites)

Compliant Standards AS/NZS 3190

The unit is fitted with 2.5mm heavy duty earth screened cable to offer

the best available protection of earthed environment safety

standards.

User/ Owners responsibility: it is required the RCBO/s are tested

prior to every use and where required by law, to ensure the unit is

regularly tested and tagged. Regular checking of the unit by a

qualified person is mandatory to the safe operation of the unit.

Powersafe recommends 3 monthly intervals for inspections.

Inspections may be required more frequently in more adverse

operating environments or under Australian Standards or Law.

Page 6: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Problem Possible Cause Suggestions to correct

No power available

at outlets

Unit not plugged in or power

point not switched onPlug into power point and turn on

RCD tripped or MCB tripped Reset the RCD toggle lever under the clear flap on the side of the unit to the on position

RCD does not trip

when testedRCD malfunction

Return to place of purchase for service. Proof of purchase will be required for warranty repairs/

replacement.

RCD continually

trips

One or more faulty appliance(s)

are connected to the Power

board

Disconnect all appliances from the power boards. Check RCD operation by depressing the test

button. The RCD should function normally.

Isolate the offending appliance and/ or consult an electrician to service the faulty item. Do not

continue to use the faulty appliance.

RCD/MCB malfunction Do not use the device. Return to place of purchase for repair/ replacement.

Excessive earth leakage current

from accumulation of a number

of appliances plugged into the

power board.

Disconnect one or more offending appliances to reduce total earth leakage current – Appliance

should be checked by a licensed electrician before proceeding.

Troubleshooting:

Page 7: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Purpose and Operation:

NEVER USE A MEGA METER ON CIRCUITS WITH AN RCD, OR DAMAGE TO THE RCD MAY OCCUR

– VOIDING WARRANTY

RCD’s are designed to prevent electrocution by detecting the leakage

current, which can be far smaller than the currents needed to operate

conventional circuit breakers or uses. RCD’s are intended to operate

within 50 milliseconds, before electric shock can drive the heart into

ventricular fibrillation the most common cause of death through electric

shock.

The “Guardian” is fitted with an RCD combination that is designed to trip

at 30 milliamps. RCD’s operate by measuring the current balance

between two conductors using a differential current transformer.

This measures the difference between the current flowing out the live

conductor and that returning through the neutral conductor. If these do

not sum to zero, there is a leakage of current to somewhere else (to

earth/ground, or to another circuit), and the device will open its contacts.

PRINCIPLE OF OPERATION

1. Principle of operation

2. Electromagnet with help electronics

3. Current transformer secondary winding

4. Transformer core

5. Test switch

Page 8: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Our product range includes large

industrial distribution boards

and cable covers

Page 9: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Earth screened extension leads and mountable

boards for generators and

workshop walls

Page 10: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Warranty:

The manufacturer warrants that the product complies with the applicable

technical specifications and is free from any defect in workmanship and

materials for a period of 5 years Pro Rata. Effective from the date of

purchase of the product and any claim under this warranty must be made

within that time period. To make a claim under warranty, ensure you

have proof of purchase; return the product to the store of purchase, or

alternatively contact Powersafe Products. The consumer is responsible

for costs to return to Powersafe and/or the store of purchase.

Powersafe undertakes to repair or replace at its option the defective

product or part thereof with a comparable product or part at least

equivalent as to the performances and functionality. The replacement

product or parts, which may be new or reconditioned, are warranted for a

period expiring either simultaneously with the initial warranty of the

concerned product or part thereof three (3) months after delivery of such

repaired product or part, whichever is later. Moreover, upon proof

evidence, the initial warranty period may be extended for the period you

have not been able to use the product due to repair. Warranty evaluation

by the manufacturer must occur prior to repair/replacement of any

product or part. All product or parts that are replaced become the

property of the manufacturer.

THIS WARRANTY DOES NOT COVER DAMAGE CAUSED BY:

• Non-compliance with the instructions for use, installation or

maintenance of the product, in particular regarding the power supply

and climatic conditions.

• Improper maintenance of energy sources and of the general

electrical installation.

• Acts of vandalism, lighting, fire, humidity, bad weather.

• Use of the product in combination with, or integration of the product

into equipment not supplied by the manufacturer, unless such

combination or integration has been expressly approved in writing by

the manufacturer.

• Use of the product for a purpose other than that for which it is

intended.

• Faults and deterioration caused by normal wear and tear, a shock or

a fall.

• Product malfunctioning due to external causes (eg radio-electric

interference produced by other equipment, variation in voltage of the

mains supply).

• Changes made to the product, including mandatory changes.

• Product from or on which the brand or serial numbers have been

removed or altered.

Page 11: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

Warranty:

• Defects as a result of other goods and services being connected to

the product which disturb or affect the predicted level of service.

Powersafe may pay reasonable direct expenses of claiming under this

warranty. You may submit details and proof of your expenses claim to

Powersafe for consideration if the failure is deemed as a warranty claim.

This warranty is provided in addition to other rights or remedies you have

under Australian Law. Our goods come with guarantees, which cannot

be excluded under Australian Consumer Law. You are entitled to

replacement, refund, or goods repaired if the goods are defective and

failure does not amount to a major failure.

UNLESS OTHERWISE STIPULATED BY LAW, ANY AND ALL

WARANTY PROVISION OTHER THAN THOSE MENTIONED HERIN

ARE EXPRESSLY EXCLUDED:

You are covered by a legal warranty for this product and for all

information concerning this warranty, please call on 1800 338 979 or

alternatively view the website and send an email directly to customer

service.

Warranty does not cover cost of freight to return the item to us and we do

not supply replacement boards until the warranty item has been

inspected by Powersafe. All warranty repairs must be carried out by

Powersafe or a company appointed by Powersafe. Any repairs carried

out prior to our approval or without our approval will not be covered

under warranty.

Ph: 1800 338 979

www.powersafe.net.au“Electrical safety us no accident”

Page 12: THE GUARDIAN OUTDOOR POWER BOARD · THE GUARDIAN OUTDOOR POWER BOARD User Guide 1800 338 979 sales@powersafe.net.au The Guardian is the only IP66 rated 4 way outdoor power board of

[email protected] 1800 338 979 www.powersafe.net.au

• Industrial Portable Power Distribution Boards• Mountable Power Distribution Boards for Generators & Workshops• Small Outdoor Power Boards• Braided Extension Leads• 3 Phase Extension Leads• Cable Covers• Lead Stands• Industrial Switchgear