The Green StandardStandard 189.1-2011, Standard for the Design of High-Performance Green Buildings
![Page 2: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/2.jpg)
What is Standard 189.1?
ANSI standard developed in model code language
Provides minimum requirements for high-performance, green buildings
Applies to all buildings except low-rise residential (same as ASHRAE/IES Standard 90.1)
Optional compliance path to the International Green Construction Code
Not a design guide or a rating system
![Page 3: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/3.jpg)
Standard 189.1 Provides
Mandatory criteria in all topic areas Simple prescriptive compliance options Flexible performance compliance options Complement green building rating
programs
![Page 4: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/4.jpg)
Sponsors and Project Committee
Sponsor and co-sponsors:– ASHRAE– USGBC (U.S. Green Building Council)– IES (Illuminating Engineering Society)
Project committee: 35+ voting members; variety of disciplines, industries & organizations
![Page 5: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/5.jpg)
ASME
BIFMA
GreenSeal
CA DHSEHLBR-174
ASTM
Std90.1
Std62.1
Std55
Guideline0
Std180
USGBC IESNA USEPA
USDOE
Std189
Standard 189.1 Building Blocks
![Page 6: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/6.jpg)
Standard 189.1 Topic Areas
Sustainable Sites
Water Use Efficiency
Energy Efficiency
Indoor Environmental QualityBuilding’s Impact on the Atmosphere, Materials & ResourcesConstruction and Operations Plans
SS
WE
EE
IEQ
MR
CO
![Page 7: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/7.jpg)
Standard 189.1 Basic Structure
x.1: Scopex.2: Compliancex.3: Mandatory (required for all projects)x.4: Prescriptive path (simple option,
minimal choices, very few calculations)x.5: Performance path (more sophisticated,
flexibility, but more effort)
![Page 8: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/8.jpg)
Compliance Paths
Mandatory + Prescriptive Path
Performance PathMandatory +
(simple option, very few calculations)
(more options, but more effort)
![Page 9: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/9.jpg)
Sustainable Sites
![Page 10: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/10.jpg)
Sustainable Sites Highlights
Site Selection
Reduce heat island effect
Reduce light pollution
![Page 11: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/11.jpg)
Water
![Page 12: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/12.jpg)
Water Use Efficiency
Mandatory Provisions Site water use Building water use HVAC Systems, equipment Water consumption management
![Page 13: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/13.jpg)
Energy
![Page 14: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/14.jpg)
Energy Efficiency
Original Standard 189.1-2009 goal 30% lower than Standard 90.1-2007 INCLUDING PROCESS
Standard 189.1-2011 goal 5-15% lower than Standard 189.1-2009
Appendix G from Standard 90.1 is incorporated as a Normative Appendix
![Page 15: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/15.jpg)
Energy Efficiency
Mandatory requirements Renewable energy provisions Remote or automatic reading
meters criteria based on size Meters communicate to central
recording system Data storage for minimum 36
months
![Page 16: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/16.jpg)
Indoor Environmental Quality
![Page 17: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/17.jpg)
Indoor Environmental Quality
Highlights Outdoor airflow Tobacco smoke control Outdoor air monitoring Filtration and air cleaning Daylighting Thermal comfort Acoustics
![Page 18: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/18.jpg)
Building’s Impact on Atmosphere, Materials and Resources
![Page 19: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/19.jpg)
Building’s Impact on Atmosphere, Materials and
ResourcesMandatory: Construction waste management No CFC based refrigerants Recyclables storage areas
![Page 20: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/20.jpg)
Construction and Operation Plans
![Page 21: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/21.jpg)
Construction and Operation Highlights
Building acceptance testing/commissioning
IAQ construction management plan Plans for operation
- High performance building operation- Maintenance- Service Life- Transportation Management
![Page 22: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/22.jpg)
Why Consider Adopting Standard 189.1?
Minimum green building requirements developed using ANSI consensus process with balanced committee, consensus must be reached by materially affected parties
ASHRAE and USGBC offers training to code officials on detailed requirements of standard
![Page 23: The Green Standard Standard 189.1-2011, Standard for the Design of High-Performance Green Buildings](https://reader035.vdocuments.site/reader035/viewer/2022062223/551b56c4550346d41a8b62d7/html5/thumbnails/23.jpg)
Further Information
Standard 189.1: www.ashrae.org/greenstandard
International Green Construction Code: www.iccsafe.org/cs/IGCC
User Manual available to assist in understanding in how to apply the standard