the goniometers

22
THE GONIOMETERS Yury Gavrikov 25/03/2009 1

Upload: thuy

Post on 12-Jan-2016

30 views

Category:

Documents


0 download

DESCRIPTION

The Goniometers. Yury Gavrikov 25/03/2009. Looking back. 1 year ago…. I met with two very nice g… oniometers. Because we decided to adapt their for a new experiment. The idea of mechanics Linear movement. Engine DC-servo motor. Gear box Belt drive + “virtual” screw. Carriage - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: The  Goniometers

1

THE GONIOMETERS

Yury Gavrikov25/03/2009

Page 2: The  Goniometers

2

Looking back

Page 3: The  Goniometers

1 year ago… I met with two very nice g…oniometers

3

Because we decided to adapt their for a new experiment

Page 4: The  Goniometers

The idea of mechanicsLinear movement

Gear boxBelt drive + “virtual”

screw

Engine DC-servo motor

Carriage slides on the 2 guides

4

Page 5: The  Goniometers

Linear motion

(full range = 90mm)(full range = 90mm)

Inside of beam

Outside of beam

5

Page 6: The  Goniometers

The idea of mechanics Angular

movement

1mm~

63m

m

AxisAxis

PusherPusher

Angle Stepper motor

&Belt driveMicroscrew

6

Page 7: The  Goniometers

ModernizationUnificated solution for angular & linear

motion:

• Stepper motor for driving

• LVDT for position measurement

• Common Control system for all devices

It was needed the mashining of original parts

7

Page 8: The  Goniometers

Mechanical revision

After modernization during last month before installation :

- 4 revisions and full disassembling- A lot of motion tests and measurements- Fixing of sources of the problems

8

Page 9: The  Goniometers

9

Measurement & Calibration

Page 10: The  Goniometers

Angle measurement Digital Autocollimator specially

designed for the experiment

Range: ~ 8000 mrad (horizontal)~ 6500 mrad (vertical)

Resolution: < 0.5mrad10

Page 11: The  Goniometers

Angle measurement

The general Idea of angle measurement

Mirror

11

Page 12: The  Goniometers

Angle calibration The Idea of crystal angle calibration

Reference mirror

Crystal

12

Page 13: The  Goniometers

Angle calibration Angle vs. LVDT position

-50000 0 50000

-7500

-5000

-2500

0

2500

5000

7500

An

gle

, u

rad

LVDT, uV

Goniometer 2Goniometer 1

-50000 0 50000

-7500

-5000

-2500

0

2500

5000

7500

Ang

le, u

rad

LVDT, uV

13

Page 14: The  Goniometers

Nonlinearity of goniometers

Periodical structure corresponds to the motor revolutionNonlinearity : about +/- 50mrad

-30000 -20000 -10000 0 10000 20000 30000-50

-40

-30

-20

-10

0

10

20

30

40

Non

linea

rity,

ura

d

LVDT, V

-30000 -20000 -10000 0 10000 20000-60

-50

-40

-30

-20

-10

0

10

20

30

No

nlin

ear

ity,

rad

LVDT, V

14

Page 15: The  Goniometers

Stability

15

The goniometers are very SENSITIVE to any mechanical disturbance

The design is SOFT. “Don’t touch” should be placed everywhere

We can move it only in work direction to avoid all gaps

Mechanical stability

Page 16: The  Goniometers

16

Stability Stability of LVDT during 14 hours looks quite good (*)

Gonio2, LVDT

3-5 mrad

(*) with averaging to reduce the noise

Page 17: The  Goniometers

Repeatability Preliminary estimation for angular motion

17

-30000 -20000 -10000 0 10000 20000 30000

-70-60-50-40-30-20-10

0102030405060708090

No

nlin

ea

rity

, ra

d

LVDT, V

Page 18: The  Goniometers

18

Alignment system

Page 19: The  Goniometers

Crystal align andAngle measurement on the tank

T ank

D i g i tal Auto c o l l i m ato r

P e ntapr i zm 1

P e ntapr i zm 2

C r ys tal 1 C r ys tal 2

R e fe r e nc e m i r r o r

19

Crystal 1

Crystal 2

Ref. mirror

Page 20: The  Goniometers

Photos of alignment system

Digital autocollimator

Reference mirror

Laser

20

Penta prizm

Viewport

Page 21: The  Goniometers

Sources of uncertainty• Initial orientation of the alignment rail to

the tank geometry +/- 350mrad• Nonlinearity of goniometers +/- 50 mrad

21

Page 22: The  Goniometers

Conclusions

We can use this goniometers with some magic gestures right now

BUT

To reach better results in the future we have to develop a new goniometer

22