Method PubertyAdenovirus quantification CZE method implementation challenges
Lars Geurink and Ewoud van Tricht
Janssen Vaccines and Prevention, the Netherlands
Melinda, Goddess of HealingMelinda’s artwork reflects her journey living with HIV.
R&D of vaccines against: Ebola, RSV, HIV, polio, influenza
2
Why?
Cell and VirusBank
Bioreactor
Cell lysis
DNA removal
Clarification Dia-filtration
Sterile filtration
Filling
Process hold
150 MDa
90 – 100 nm
dsDNA
AEX-filtration
3 days 3 h?
3.5 min
3
Why?
Cell and VirusBank
Bioreactor
Cell lysis
DNA removal
Clarification Dia-filtration
Sterile filtration
Filling
Process hold
150 MDa
90 – 100 nm
dsDNA
AEX-filtration
3 h
3.5 minTalanta, Volume 166, 1 May 2017, Pages 8–14
4
Method transfer sites
-Process development
-Process Development-Analytical testing nonQC-QC
5
Puberty?
Method life time
Met
ho
d p
erf
orm
ance
Met
ho
d c
on
tro
l
6
Method transfer preparation
Mother natureMachine
Method installation
Material
Measurement
Men Methods
Controls
Chemicals
Consumables
Operators
Training
Skills
Knowledge
Co-validation
System suitability control
Capillary electrophoresis
Glassware
Analytical balance
Sonification bath
BSL II lab
Internet connection
Pressurized nitrogen
Temperature controlled
Trending
Issue log
Recurrent meetings
Intensive care
New Scopes
7
Method transfer preparation
8
Training
Trouble-shooting
CE practice
Method practice
Software practice
CE
theory
CE best practices
Instrument theory
Set up best practices
Software theory
Trending - Critical method performance parameter
System suitability test based on risk assessment
9
CMP Potential failure effect
Potential failure mode I P D RPN Mitigation I P D RPN
Reference material storage
Accuracy The RM degrades. Test articles are overestimated because the RM has contains less of the component than determined resulting in a lower signal.
9 6 9 486 Store RM at <-65 °C controlled freezer
9 2 9 162
Reference material storage
Accuracy The RM degrades. Test articles are overestimated because the RM has contains less of the component than determined resulting in a lower signal.
9 6 9 486 Trend peak area
9 6 3 162
Sum 9 2 3 54
DevelopmentImplementation
Trending – example
10
External pipetting training
Internal pipetting alignment training
Changed to P1000Instead of P200
Changed back to use the P200
Instrument preparation
Solution preparation
Sample preparation
System suitability
testing
Sample testing
Data interpretation
Reporting
Issue log
11
Any error, delay, obstacle on the way Log issue
KPIsCI
Problem solving
FMEA
12
Cumulative method down time
0
2
4
6
8
10
12
14
16
18
Tota
l do
wn
tim
e [
h]
Solution
Problem solving
Capillary quality
Bad cut
Breakdown before first run
Heat and condense in summer
Environment lab repeatability
Missing vials stop sequence
Pressure systems
1) Cleaning
2) Reinstallation pre-puncher electrodes
3) Replacement of pressure lines
4) Handling of pressurelines during cleaning
Instrument badly manufactured (1y)
Problem solving
13
Performance
14
0
5
10
15
20
25
30
35
0
200
400
600
800
1000
1200
1400
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7
2015 2016 2017 2018
Nu
mb
er o
f ru
ns
Nu
mb
er o
f sa
mp
les
Samples
Runs
0
2
4
6
8
10
12
14
16
0
2
4
6
8
10
12
14
16
18
20
1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 1 2 3 4 5 6 7
2015 2016 2017 2018
Nu
mn
er o
f is
sues
Do
wn
tim
e [h
]
Date
Downtime (h)
Issues
DS/DP QC
New purposes? – Poster 108
15
IPC AEX eluate
DB interaction
IPC BCH IPC QC
DS/DP
Serotypes
DS/DP stability
DS/DP routine
Higher sensitivity
CrudeCrude routine Seed release QC
New purposes
16
CZE adenovirus
GMP
IPCGMP
DS/DP R&S
GMP
Virus seed R
IPC
Process development
support
Formulation development
supportDSP/DP characterization
New serotypes
Stability of process
intermediates
Clogging of AEX filtration
Adenovirus Domipheninteraction
Triton X-100 replacement
QC
Development support
Investigation
New purpose installation
17
Investigation
Explorative question
Just do it
Development
support
Test feasibility
Optimize method
Test performance
Adjust procedure
Train operators
QC
Use development support knowledge
Change control
Train operators
Qualify method
18
Method installation preparation
19
Implementation statistics (3 years)
20 operators
8 instruments
2 software packages
7 application
5 investigations
6 locations
2 invalids
500 $ saved per analysis
3 h instead of 3 days
15000 samples
20
Future
> +10 operators
Any instruments
All on Empower
3 locations
No recurrent issues
Continuous improvement culture
Safe, effective vaccines
▪ Special thanks to Ewoud van Tricht and Cari Sänger - van de Griend
Acknowledgement
21
Talanta, Volume 166, 1 May 2017, Pages 8–14
Ph.D. supervisors
▪ Cari Sänger – van de Griend
▪ Martijn Schenning
▪ Curt Patterson
Analytical Development
▪ Harold Backus
▪ AA group
▪ Process support (PDS)
▪ QC (QCD)
PD department
Statistics
Prepare for method puberty
22