Nemko USA, Inc. 2210 Faraday Ave, Suite 150 Carlsbad, CA 92008 Phone (760) 444-3500 Fax (760) 444-3005 TEST REPORT PER RCTA/D0-160G FOR THE DS1921G-F5#, DS1922L-F5#, DS1925L-F5# DATA LOGGERS PREPARED FOR Maxim Integrated Products 14460 MAXIM DRIVE DALLAS, TX 75244 USA REVISION 1 PREPARED ON JULY 11, 2016 REPORT NUMBER 2016 07313140 RTCA R1 PROJECT NUMBER: 313140 QUOTE NUMBER: Q102104018

Upload: lynhu

Post on 19-Aug-2018

233 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

Nemko USA, Inc.

2210 Faraday Ave, Suite 150

Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

TEST REPORT

PER RCTA/D0-160G

FOR THE DS1921G-F5#, DS1922L-F5#, DS1925L-F5#

DATA LOGGERS

PREPARED FOR

Maxim Integrated Products

14460 MAXIM DRIVE

DALLAS, TX 75244 USA

REVISION 1

PREPARED ON JULY 11, 2016

REPORT NUMBER 2016 07313140 RTCA R1

PROJECT NUMBER: 313140

QUOTE NUMBER: Q102104018

Page 2: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 ii of 121

DOCUMENT HISTORY

REVISION DATE COMMENTS

0 July 11, 2016 Prepared By: Lan Sayasane

0 June 26, 2007 Released By: Jim Morris

1 July 19, 2007 Correct Model # Jim Morris

NOTE: Nemko USA, Inc. hereby makes the following statements so as to conform to the Requirements of EN

17025 "General Criteria For the Operation Of Test Laboratories":

The units described in this report were received at Nemko USA, Inc.'s facilities on July 8, 2016. Testing

was performed on July 11, 2016.

The Test Results reported herein apply only to the Unit actually tested, and to substantially identical Units.

This Report is the property of Nemko USA, Inc., and shall not be reproduced, except in full, without prior written

approval of Nemko USA, Inc. However, all ownership rights are hereby returned unconditionally to Independent

Testing Laboratories Inc., and approval is hereby granted to Independent Testing Laboratories Inc. and its employees

and agents to reproduce all or part of this report for any legitimate business purpose without further reference to

Nemko USA, Inc.

Page 3: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 iii of 121

TABLE OF CONTENTS

1. ADMINISTRATIVE DATA AND TEST SUMMARY ........................................................................................ 6

1.1 Administrative Data ....................................................................................................................................... 6

1.2 Test Summary ................................................................................................................................................ 7

1.3 Emissions Test Summary ............................................................................................................................... 7

2. SYSTEM CONFIGURATION .............................................................................................................................. 8

2.1 System Components and Power Cables ......................................................................................................... 8

2.2 Device Interconnection and I/O Cables ......................................................................................................... 8

2.3 Design Modifications for Compliance ........................................................................................................... 8

3. TEST SITE INFORMATION ................................................................................................................................ 9

3.1 Ground Plane ................................................................................................................................................. 9

3.2 Anechoic Chamber ......................................................................................................................................... 9

3.3 Detection System ........................................................................................................................................... 9

3.4 Test Equipment .............................................................................................................................................. 9

4. DESCRIPTION OF UUT SET-UP AND MODES OF OPERATION ............................................................. 11

4.1 Test Specifics ............................................................................................................................................... 11

4.2 Modes of Operation during EMC Testing ................................................................................................... 11

4.3 Figure and Picture of actual test Set-up ....................................................................................................... 12

5. BONDING AND EMISSION CONTROL .......................................................................................................... 13

5.1 Bonding Test ................................................................................................................................................ 13 5.1.1 Bonding Test Method 13

5.1.2 Bonding Data Sheets 13

5.1.3 Bonding Photographs 13

5.1.4 Bonding Equipment List 13

5.2 Radiated RF Emissions ................................................................................................................................ 14 5.2.1 Radiated RF Emissions Test Method 14

5.2.2 Radiated RF Emissions Test Data 16

5.2.3 Radiated RF Emissions Photographs 19

5.2.4 Radiated RF Emissions Test Equipment List 22

APPENDIX A – CALIBRATION PROGRAM ...................................................................................................... 23

Page 4: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 iv of 121

LIST OF FIGURES

FIGURE 4.3-1 UUT TEST SETUP ................................................................................................................................... 12 FIGURE 5.1-1 TEST CONFIGURATION ............................................................................................................................ 15 FIGURE 5.1-2: 100 MHZ – 200 MHZ - VERTICAL ......................................................................................................... 16 FIGURE 5.1-3: 100 MHZ – 200 MHZ - HORIZONTAL ..................................................................................................... 16 FIGURE 5.1-4: 200 MHZ – 960 MHZ - VERTICAL ......................................................................................................... 17 FIGURE 5.1-5: 200 MHZ – 960 MHZ - HORIZONTAL ..................................................................................................... 17 FIGURE 5.1-6: 960 MHZ – 6000 MHZ - VERTICAL ....................................................................................................... 18 FIGURE 5.1-7: 960 MHZ – 6000 MHZ - HORIZONTAL ................................................................................................... 18 FIGURE 5.1-8: 100 MHZ TO 200 MHZ – VERTICAL....................................................................................................... 19 FIGURE 5.1-9: 100 MHZ TO 200 MHZ – HORIZONTAL .................................................................................................. 19 FIGURE 5.1-10: 200 MHZ TO 960 MHZ – VERTICAL..................................................................................................... 20 FIGURE 5.1-11: 200 MHZ TO 960 MHZ – HORIZONTAL ................................................................................................ 20 FIGURE 5.1-12: 960 MHZ TO 6000 MHZ – VERTICAL................................................................................................... 21 FIGURE 5.1-13: 960 MHZ TO 6000 MHZ – HORIZONTAL .............................................................................................. 21

Page 5: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 v of 121

CERTIFICATION

The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent

electromagnetic compatibility consulting and test laboratory. Testing was performed Per test methods described

in RCTA/DO-160G.

I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the

sample's immunity and emission characteristics, as of the test date(s), and for the design of the test sample utilized to

compile this report.

James Morris

EMC and Wireless Manager

Nemko USA, Inc., 2210 Faraday Avenue, Suite 150

Carlsbad, CA 92008, USA

Page 6: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 6 of 121

1. ADMINISTRATIVE DATA AND TEST SUMMARY

1.1 Administrative Data

CLIENT: Maxim Integrated Products

CONTACT: Stewart Merkel

DATE (S) OF TEST: July 11, 2016

EQUIPMENT UNDER TEST (): Data Loggers

Part Number: DS1921G-F5#, DS1922L-F5#, DS1925L-F5#

Serial Number 165EA5, 38C201, 008CFB

Condition Upon Receipt Acceptable

TEST SPECIFICATIONS: Radio Frequency Emissions and Electromagnetic Immunity tests

in accordance with the requirements of RCTA/DO-160G.

Emission Tests

Test

Method

Requirement Description Frequency Range Limit

21.5 RCTA/DO-160G Radiated RF Emissions 100 MHz – 6000 MHz Category H

Page 7: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 7 of 121

1.2 Test Summary

1.3 Emissions Test Summary

Specification Frequency Range Compliance Status

Section 21.5 100 MHz – 6000 MHz Compliant

Refer to the test results section for further details.

James Morris

EMC and Wireless Manager

Nemko USA, Inc., 2210 Faraday Avenue, Suite 150

Carlsbad, CA 92008, USA

Page 8: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 8 of 121

2. SYSTEM CONFIGURATION

2.1 System Components and Power Cables

None

2.2 Device Interconnection and I/O Cables

None

2.3 Design Modifications for Compliance

None

Page 9: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 9 of 121

3. TEST SITE INFORMATION

The test site is located at:

NEMKO USA, Inc.

2210 Faraday Ave., Suite 150

Carlsbad, CA 92008

NEMKO USA is NVLAP certified. The NVLAP Certification is included in Appendix C of this document.

The site is physically located 18 miles Northwest of downtown San Diego. The general area is a valley 1.5

miles east of the Pacific Ocean. The EMI testing was under the guidance of National Association of Radio and

Telecommunication Engineers (NARTE) personnel.

3.1 Ground Plane

The emissions and susceptibility portions of the testing was performed on a ground plane. The ground plane

consisted of a 8’ x 3’ x 1/8” thick copper plate mounted on a wooden bench and is connected to the ground rod

via a copper bus bar 2’ wide and 0.25" thick. The DC bonding resistance between the ground plane and ground

was less than 2.5m. The Unit Under Test (UUT) and LISNs were bonded to the ground plane.

3.2 Anechoic Chamber

The radiated and conducted emissions tests were conducted inside a semi anechoic chamber which measures 20'

x 12' x 10'. Carbon-loaded cones provide RF dissipation. Radiated susceptibility tests were conducted inside a

semi anechoic chamber which measures 20' x 12' x 10’. Power capability of the chamber includes 50 amps at

100VDC, 30 amps per phase of 120 VAC at 400 Hz, and 50 amps of up to 250 VAC at up to 60 Hz.

3.3 Detection System

The automated detection system used in emission testing consist of a spectrum Analyzer controlled by a

computer. Preamplifiers used where necessary and where they are used an appropriate notation is made in the

relevant section of the report. Commercially available EMI measurement software Total Integrated Laboratory

Environment (TILE) was used in the performance of these measurements. In this software package, the

bandwidths and measurement times are user-selectable, and the bandwidths and sweep times were per the

requirements of RTCA/DO-160G.

3.4 Test Equipment

NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in order to ensure the validity of all

test data. NEMKO USA’s Periodic Calibration Program is fully compliant to the requirements of NVLAP

Policy Guide PG-1-1988, ANSI/NCSL Z540-1 (1994), ISO 10012-1 (1993-05-01), ISO Standard 17025, ISO-

9000 and EN 45001. NEMKO USA, Inc.’s calibration program therefore meets or exceeds the US national

commercial and military requirements [N.B. ANSI/NCSL Z540-1 (1994) replaces MIL-STD-45662A].

Page 10: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 10 of 121

Specifically, all of NEMKO USA’s primary reference standard devices (e.g. vector voltmeters, multimeters,

attenuators and terminations, RF power meters and their detector heads, oscilloscope mainframes and plug-ins,

spectrum analyzers, RF preselectors, quasi-peak adapters, interference analyzers, impulse generators, signal

generators and pulse/function generators, field-strength meters and their detector heads, etc.) and certain

secondary standard devices are periodically recalibrated by:

A NEMKO USA-approved independent (third party) metrology laboratory that uses NIST-traceable

standards and that is ISO Standard 17025-accredited as a calibration laboratories by NIST; or,

A NEMKO USA-approved independent (third party) metrology laboratory that uses NIST-traceable

standards and that is ISO Standard 17025-accredited as a calibration laboratory by another accreditation

body (such as A2LA) that is mutually recognized by NIST; or,

A manufacturer of Measurement and Test Equipment (M&TE), if the manufacturer uses NIST-traceable

standards and is ISO Standard 17025-accredited as calibration laboratory either by NIST or by another

accreditation body (such as A2LA) that is mutually recognized by NIST; or

A manufacturer of M&TE (or by a NEMKO USA-approved independent third party metrology laboratory)

that is not ISO Standard 17025-accredited. (In these cases, NEMKO USA conducts an annual audit of the

manufacturer or metrology laboratory for the purposes of proving traceability to NIST, ensuring that

adequate and repeatable calibration procedures are being applied, and verifying conformity with the other

requirements of ISO Standard 17025).

In all cases, the entity performing the Calibration is required to furnish NEMKO USA with a calibration test

report and/or certificate of calibration, and a “calibration sticker” on each item of M&TE that is successfully

calibrated.

Calibration intervals are normally one year, except when the manufacture advises a shorter interval or if US

Government directives or client requirements demand a shorter interval. Items of instrumentation/related

equipment which fail during routine use, or which suffer visible mechanical damage (during use or while in

transit), are sidelined pending repair and recalibration. (Repairs are carried out either in-house [if minor] or by a

NEMKO USA-approved independent [third party] metrology laboratory, or by the manufacturer of the item of

M&TE).

Each antenna used for radiated emissions testing is calibrated annually by either a NIST (or A2LA) ISO

Standard 17025-Accredited third-party Antenna Calibration Laboratory or by the antenna’s OEM if the OEM is

NIST or A2LA ISO Standard 17025-accredited as an antenna calibration laboratory.

Page 11: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 11 of 121

4. Description of UUT Set-up and Modes of Operation

4.1 Test Specifics

The equipment lists for each EMI/EMC test is contained in the EMI test Sections 5.2.4. Serial numbers,

calibration due dates, and equipment used were recorded at test time. Instrumentation calibrations are traceable

to the National Institute of Standards and Technology.

A PC computer external to the test room was used in conjunction with the RTS version A for testing. The PC

used to simulate actual communications was used to also verify the signal integrity during the evaluation.

Functional performance tests on the UUT were performed prior to each test performed. These established the

base line parameters and verified the proper UUT operation. During the actual testing the communications was

monitored to verify normal UUT operation.

4.2 Modes of Operation during EMC Testing

During the EMI/EMC evaluation the unit will continuously operate for 12 hours. The configuration were set

according: DS1921G -> Every 1 minute (Max Rate), DS1922L -> Every 11 seconds, Resolution 0.0625 (4096

samples up to 12.5 hours), DS1925L -> Every 300 seconds, Resolution 0.0625 (Datasheet sheet recommended

lower limit is every 5 minutes or 300 seconds).

Page 12: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 12 of 121

4.3 Figure and Picture of actual test Set-up

Figure 4.3-1 UUT Test Setup

Page 13: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 13 of 121

5. Bonding and Emission Control

5.1 Bonding Test

5.1.1 Bonding Test Method

Per RTCA/DO-160G the bonding between the UUT, LISN’s and ground plane were measured and verified to be

less than 2.5 milli ohms.

Test Dates: July 11, 2016

Test Results: Passed

5.1.2 Bonding Data Sheets

Customer: Maxim Integrated Products

Job order: 313140

Test Engineer: Lan Sayasane

Date: July 11, 2016

Standard: RTCA/DO-160G

Remarks: Section 21.5 – Radiated RF Emissions

From

Location

To

Location

Measured

mΩ Limit

Pass

(√ )

Remarks

Table Ground Plane Ground Strap 0.02 2.5 √

5.1.3 Bonding Photographs

5.1.4 Bonding Equipment List

Asset No.: Description: Company: Model Number: Serial Number: Date Cal: Cal Due Date:

D1851 Milliohm Meter Extech 380560 DA4017 12/30/2015 12/30/2016

Page 14: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 14 of 121

5.2 Radiated RF Emissions

5.2.1 Radiated RF Emissions Test Method

The purpose of this test was to measure the electric field radiated emissions produced by the UUT and

associated cabling and to determine whether these emissions are in compliance with the requirements of

RTCA/DO-160G.

The UUT configured as shown in Figure 4.3.1 inside the anechoic chamber. The field-measuring antenna was

placed inside the chamber and connected via coaxial cable through the bulkhead panel to the detection system

located outside the chamber. The detection system consisted of a Spectrum Analyzer controlled by a Computer.

A number of antennas were used to cover the frequency range required in this test.

The operation of the UUT was verified. Measurements were then performed of the radiated electric field

emissions produced by the UUT. The data was reduced and plotted together with the applicable limit. The

Limit is per RTCA/DO-160G, Figure 21-9: Maximum Level of Radiated RF Interference – Category H.

Test Results: The UUT passed the radiated emissions testing as demonstrated in the plots below.

Page 15: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 15 of 121

Figure 5.1-1 Test Configuration

Page 16: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 16 of 121

5.2.2 Radiated RF Emissions Test Data

Figure 5.1-2: 100 MHz – 200 MHz - Vertical

Nemko USA

RTCA/DO-160G Section 21.5 - Radiated Emissions

Biconical - 100 MHz - 200 MHz - Operational - Vertical

100.0M 200.0M

Frequency

-50.0

-40.0

-30.0

-20.0

-10.0

0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

Am

pli

tud

e d

Bu

V/m

01:11:52 PM, Monday, July 11, 2016

Operator: LS

Company - Maxim Integrated Products

Test Item - Data Loggers

Model No - DS1921G-F5#, DS1922L-F5# & DS1925L-F5#

SpecLimit

E_BiconV_F

Figure 5.1-3: 100 MHz – 200 MHz - Horizontal

Nemko USA

RTCA/DO-160G Section 21.5 - Radiated Emissions

Biconical - 100 MHz - 200 MHz - Operational - Horizontal

100.0M 200.0M

Frequency

-50.0

-40.0

-30.0

-20.0

-10.0

0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

Am

pli

tud

e d

Bu

V/m

01:14:41 PM, Monday, July 11, 2016

Operator: LS

Company - Maxim Integrated Products

Test Item - Data Loggers

Model No - DS1921G-F5#, DS1922L-F5# & DS1925L-F5#

E_BiconH_F

SpecLimit

Page 17: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 17 of 121

Figure 5.1-4: 200 MHz – 960 MHz - Vertical

Nemko USA

RTCA/DO-160G Section 21.5 - Radiated Emissions

Double Ridge Horn-Low - 200 MHz - 960 MHz - Operational - Vertical

200.0M 960.0M

Frequency

-50.0

-40.0

-30.0

-20.0

-10.0

0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

Am

pli

tud

e d

Bu

V/m

01:04:11 PM, Monday, July 11, 2016

Operator: LS

Company - Maxim Integrated Products

Test Item - Data Loggers

Model No - DS1921G-F5#, DS1922L-F5# & DS1925L-F5#

SpecLimit

E_DRGloV_F

E_DRGloV_F1

Figure 5.1-5: 200 MHz – 960 MHz - Horizontal

Nemko USA

RTCA/DO-160G Section 21.5 - Radiated Emissions

Double Ridge Horn-Low - 200 MHz - 960 MHz - Operational - Horizontal

200.0M 960.0M

Frequency

-50.0

-40.0

-30.0

-20.0

-10.0

0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

Am

pli

tud

e d

Bu

V/m

12:51:50 PM, Monday, July 11, 2016

Operator: LS

Company - Maxim Integrated Products

Test Item - Data Loggers

Model No - DS1921G-F5#, DS1922L-F5# & DS1925L-F5#

SpecLimit

E_DRGloH_F

E_DRGloH_F1

Page 18: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 18 of 121

Figure 5.1-6: 960 MHz – 6000 MHz - Vertical

Nemko USA

RTCA/DO-160G Section 21.5 - Radiated Emissions

Double Ridge Horn-High - 960 MHz - 6 GHz - Operational - Vertical

960.0M 6.0G

Frequency

-10.0

0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

100.0

Am

pli

tud

e d

Bu

V/m

11:57:48 AM, Monday, July 11, 2016

Operator: LS

Company - Maxim Integrated Products

Test Item - Data Loggers

Model No - DS1921G-F5#, DS1922L-F5# & DS1925L-F5#

SpecLimitE_1_4VDRG_FE_4_8VDRG_FE_8_12VDRG_FE_12_18VDRG_F

Figure 5.1-7: 960 MHz – 6000 MHz - Horizontal

Nemko USA

RTCA/DO-160G Section 21.5 - Radiated Emissions

Double Ridge Horn-High - 960 MHz - 6 GHz - Operational - Horizontal

960.0M 6.0G

Frequency

-10.0

0

10.0

20.0

30.0

40.0

50.0

60.0

70.0

80.0

90.0

100.0

Am

pli

tud

e d

Bu

V/m

11:41:51 AM, Monday, July 11, 2016

Operator: LS

Company - Maxim Integrated Products

Test Item - Data Loggers

Model No - DS1921G-F5#, DS1922L-F5# & DS1925L-F5#

SpecLimitE_1_4HDRG_FE_4_8HDRG_FE_8_12HDRG_FE_12_18HDRG_F

Page 19: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 19 of 121

5.2.3 Radiated RF Emissions Photographs

Figure 5.1-8: 100 MHz to 200 MHz – Vertical

Figure 5.1-9: 100 MHz to 200 MHz – Horizontal

Page 20: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 20 of 121

Figure 5.1-10: 200 MHz to 960 MHz – Vertical

Figure 5.1-11: 200 MHz to 960 MHz – Horizontal

Page 21: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 21 of 121

Figure 5.1-12: 960 MHz to 6000 MHz – Vertical

Figure 5.1-13: 960 MHz to 6000 MHz – Horizontal

Page 22: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 22 of 121

5.2.4 Radiated RF Emissions Test Equipment List

Asset No.: Description: Company: Model Number: Serial Number: Last Cal. Cal due

E1064 Spectrum Analyzer Agilent E4440A US42221762 2/15/2016 2/15/2017

E1029 Pre-amplifier A.H. Systems, Inc. PAM-0118 343 9/9/2016 9/9/2016

827 Pre-amplifier Com-Power PA-103 161032 3/8/2016 3/8/2017

117 Antenna, Biconical Electro-Metrics BIA-25 2611 3/22/2016 3/22/2017

E1014 Antenna, Dual Ridge A.H.Systems, Inc. SAS-570 174 12/12/2015 12/12/2016

752 Antenna, DRG Horn EMCO 3115 9609-4943 4/5/2016 4/5/2017

Page 23: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 23 of 121

APPENDIX A – Calibration Program

Nemko USA, Inc.’s Test Equipment & Facilities Calibration Program

Nemko USA, Inc. operates a comprehensive Periodic Calibration Program in order to ensure the validity of all test

data. Nemko USA’s Periodic Calibration Program is fully compliant to the requirements of NVLAP Policy Guide

PG-1-1988, ANSI/NCSL Z540-1 (1994), ISO 10012-1 (1993-05-01), ISO Standard 17025, ISO-9000 and EN

45001. Nemko USA, Inc.’s calibrations program therefore meets or exceed the US national commercial and military

requirements [N.B. ANSI/NCSL Z540-1 (1994) replaces MIL-STD-45662A].

Specifically, all of Nemko USA’s primary reference standard devices (e.g. vector voltmeters, multimeters,

attenuators and terminations, RF power meters and their detector heads, oscilloscope mainframes and plug-ins,

spectrum analyzers, RF preselectors, quasi-peak adapters, interference analyzers, impulse generators, signal

generators and pulse/function generators, field-strength meters and their detector heads, etc.) and certain secondary

standard devices (e.g. RF Preamplifiers used in CISPR 11/22 and FCC Part 15/18 tests) are periodically recalibrated

by:

A Nemko USA-approved independent (third party) metrology laboratory that uses NIST-traceable standards and

that is ISO Standard 17025-accredited as a calibration laboratories by NIST; or,

A Nemko USA-approved independent (third party) metrology laboratory that uses NIST-traceable standards and

that is ISO Standard 17025-accredited as a calibration laboratory by another accreditation body (such as A2LA)

that is mutually recognized by NIST; or,

A manufacturer of Measurement and Test Equipment (M&TE), if the manufacturer uses NIST-traceable

standards and is ISO Standard 17025-accredited as calibration laboratory either by NIST or by another

accreditation body (such as A2LA) that is mutually recognized by NIST; or

A manufacturer of M&TE (or by a Nemko USA-approved independent third party metrology laboratory) that is

not ISO Standard 17025-accredited. (In these cases, Nemko USA conducts an annual audit of the manufacturer

or metrology laboratory for the purposes of proving traceability to NIST, ensuring that adequate and repeatable

calibration procedures are being applied, and verifying conformity with the other requirements of ISO Standard

17025).

In all cases, the entity performing the Calibration is required to furnish Nemko USA with a calibration test report

and/or certificate of calibration, and a “calibration sticker” on each item of M&TE that is successfully calibrated.

Page 24: TEST REPORT - Maxim Integrated - Analog, linear, & … · requirements of RTCA/DO-160G. 3.4 Test Equipment NEMKO USA, Inc. operates a comprehensive Periodic Calibration Program in

NemkoSD USA, Inc. 2210 Faraday Ave., Suite 150, Carlsbad, CA 92008

Phone (760) 444-3500 Fax (760) 444-3005

REVISION DATE DOCUMENT NAME DOCUMENT # PAGE

0 July 11, 2016 MAXIM INTEGRATED PRODUCTS, DATA LOGGERS 2016 07313140 RTCA R1 24 of 121

Calibration intervals are normally one year, except when the manufacture advises a shorter interval (e.g. the HP

8568B Spectrum Analyzer is recalibrated every six months) or if US Government directives or client requirements

demand a shorter interval. Items of instrumentation/related equipment which fail during routine use, or which suffer

visible mechanical damage (during use or while in transit), are sidelined pending repair and recalibration. (Repairs

are carried out either in-house [if minor] or by a Nemko USA-approved independent [third party] metrology

laboratory, or by the manufacturer of the item of M&TE).

Each antenna used for CISPR 11 and CISPR 22 and FCC Part 15 and Part 18 radiated emissions testing (and for

testing to the equivalent European Norms) is calibrated annually by either a NIST (or A2LA) ISO Standard 17025-

Accredited third-party Antenna Calibration Laboratory or by the antenna’s OEM if the OEM is NIST or A2LA ISO

Standard 17025-accredited as an antenna calibration laboratory. The antenna calibrations are performed using the

methods specified in Annex G.5 of CISPR 16-1(1993) or ANSI C63.5-1991, including the “Three-Antenna

Method”. Certain other kinds of antennas (e.g. magnetic-shielded loop antennas) are calibrated annually by either a

NIST (or A2LA) ISO Standard 17025-accredited third-party antenna calibration laboratory, or by the antenna’s

OEM if the OEM is NIST or A2LA ISO Standard 17025-accredited as an antenna calibration laboratory using the

procedures specified in the latest version of SAE ARP-958.

In accordance with FCC and other regulations, Nemko USA recalibrates its suite of antennas used for radiated

emissions tests on an annual basis. These calibrations are performed as a precursor to the FCC-required annual

revalidation of the Normalized Site Attenuation properties of Nemko USA’s Open Area Test Site. Nemko USA, Inc.

uses the procedures given in both Subclause 16.6 and Annex G.2 of CISPR 16-1 (1993), and, ANSI C63.4-1992

when performing the normalized site attenuation measurements.