tender for the furnishing of vijaya bank at …€¦ · web view2013-11-04 · providing table...
TRANSCRIPT
ISSUED TO M/S ______________________________
TENDER DOCUMENT
FOR
FURNISHING OF
E – LOBBY AT
ALLAHABAD BANK BRANCH, PHASE – 9, MOHALI.
OFFICE OF
ASSTT. GENERAL MANAGER
ALLAHABAD BANK ZONAL OFFICE,
LUDHIANA -141001; Phone-0161-2440035
)
TENDER F OR PROPOSED E-LOBBY AT ALLAHABAD BANK BRANCH , PHASE-9 , MOHALI.
1. Details of work to be done : Interior / furnishing & Allied Electrical Work
2. Form of Contract : Item wise rate
3. Period of contract / Time of completion : 30 Days
4. Last Date & time for receiving : 15.11.2013.
of sealed tender.
5. Liquidated damages for non : 1.0% of the contract value per week
Completion of work in time subject to a max of 10 % of the contract value
6. Defect Liability period : 12 months (twelve months) from the date
of virtual completion as certified by Architect / employer.
7. Retention amount for 12 months : 5% of the total bill.
8. Period of submitting of final bill. : 15 days from the date of completion.
9. Place and date of opening of : Zonal Office, Ludhiana at 3.00 p.m. in the office of the
Tenders Asstt. General Manager, Allahabad Bank Zonal Office,
Ludhiana..
ASSTT. GENERAL MANAGER
ALLAHABAD BANK
ZONAL OFFICE, LUDHIANA.
GENERAL CONDITIONS FOR TENDER OF ALLAHABAD BANK E-LOBBY AT PHASE-9 BRANCH , MOHALI.
1. Each page of this tender shall be signed by the contractor.
2. Payment to the Contractor Agency shall be made as per actual work done at site.
3. Quantities of work may increase or decrease at site as per requirement, which shall
not affect the rates quoted by the contractor.
4. Furnishing works including electrical works etc. shall be done to the complete
satisfaction of Bank and Architect –in – charge.
5. All Teak / Cedar wood / rubber wood to be used should be Knotless which is to be
polished with all background surface preparation coarses
Maintaining the visibility of wood grains.
6. The rates to be quoted shall include the cost of material, labour charges, carriage,
sales-tax, or any / all other taxes required.
7. The contractor agency shall keep particular vigil on his workers / carpenters / painters
etc. to maintain very good workmanship of all items, failing which no payment shall be
made and on claim of material / labour used shall be made to him in any case, and
the same work shall be executed by him again without charging any extra cost.
8. All rates shall be quoted in words & figures & any cutting, over writing shall be signed.
9. All items to be executed as per drawings. If any change is required, the same shall be
brought to the notice of Architect – in – Charge.
10. Any tender / quotation containing clerical or arithmetical mistakes shall be rejected.
11. Any addition, alteration or correction shall be signed and stamped properly.
12. Contractor agencies are advised (before quoting the rates) to inspect the site of the
proposed work. He must go through all drawings and specifications and documents.
13. The Bank reserves the right to accept / reject any tender / quotation without assigning
reason.
14. The Contractor agency should have already executed works of furnishing interiors &
exterior, civil works of very good workmanship.
15. Quality of material and workmanship rejected by the Architect / Concerned Authorities
shall be removed immediately by the contractor and rectified / replaced.
16. No advance payment shall be made to the Contractor on supply of any material
supplied at site for execution. Payment shall only be made on execution of any
concerned / particular item.
17. The rates shall include the cost of coat of anti termite treatment on all wooden frame
work and all commercial ply / board used for partitions and panelling, furniture etc.
The contractor /s shall have to dismantle & dispose the existing counters, tables &
partitions within the quoted cost of the total furnishing works.
18. Rates for partitions, paneling, wall cladding and false ceiling shall include cutting and
making good of necessary cut – outs / chiseling to be made for electrical conduits,
switch boards etc.
19. Bank shall not be responsible for any lose or damage to the contractor / labour due to
any natural calamity during the course of construction. Contractor is liable to make
good all the damages if any, till the work is completed and handed over to the Bank
authorities.
20. Any payment to the contractor on account of execution of work, whether it is running
payment or final, shall be verified by the Architect – in – Charge.
21. Unless, otherwise mentioned all materials to be used shall be I.S.I. marked. Failure to
do so, the work may be rejected and in that case contractor shall have to remove the
defective materials and replace / re-do the work for which no claim shall be
entertained.
22. The total work shall be supervised by the Architect –in – charge and he / she shall be
kept fully informed by the contractor regarding the progress of work.
23. Bank may award the work in part or whole to a single party or any other party.
24. It may please be noted that the Bank is not bound to allot the work to the lowest
party. And as such, the allotment of work shall be based on workability of rates
quoted by the contractor on account of quality work.
25. The bank reserves the right to reject any or all the tenders without assigning any
reason whatsoever.
26. The earnest money deposited shall not carry any interest and will be refunded to the
unsuccessful tenderers.
27. Earnest money paid by the contractor shall be forfeited by the Bank if contractor fails
to undertake the job if he is communicated about acceptance his rates / tender.
28. The contractor shall take all the necessary precautions while working and to safe
guard adjacent property, Bank’s Employees, and traffic persons.
29. All the rates quoted are inclusive of removal of rubbish / debris collected during the
progress of work, rejected materials etc.
30. The contractor shall not directly or indirectly sublet the work to other party without
written permission of the Bank.
31. The quantities mentioned in schedule are provisional and likely to increase / decrease
to any extent or may be omitted thus altering the aggregate value of the contract . No
claim for loss or profit / business shall be entertained on this account.
32. The Bank reserves the right to distribute the work for which quotations have been
called, among more than one parties, if found necessary .No claim in this respect
shall be considered and the contractor agrees to cooperate with other agencies
appointed by the Bank.
33. All the workers of the contractor must be properly covered by an insurance policy
under “ Workman’s Compensation act ” and “ Fatal Accidents Act “ .The contractor at
his own expenses arrange to effect and maintain until the virtual completion of the
work , and indemnify the bank from all the liabilities arising out of such events. In
Case of delay, contractor shall arrange to extend insurance policy till work is
Completed.
34. All the work should be completed within the specified period in the tender. If the work
is delayed due to the reasons beyond the control of the contractor, he should keep
intimating the Bank explaining, therein the reasons for such delays, immediatanBif in
the opinion Bank’s authorities the delay is justified, the contractor shall be granted
extension in time limit.
35. The contractor shall furnish well in time before work commencement at his own cost,
colour samples, samples of materials or workmanship that may be called by Bank’s
Architect / Engineer for approval. Rates quoted shall cover for such preliminary work.
36. All the glass panes, door handles / hinges, electric fitting, fans, furniture, records,
floors etc. are to be thoroughly cleaned after the work is completed.
37. The rates quoted by the contractor shall be firm throughout the duration of contract
(including extension of time if any granted) and will not be subject to any fluctuation
due to variation in cost of material and labour.
38. Conditional tenders are liable to be rejected.
39. The successful tenderer is bound to carry out any item of work necessary for the
completion of the job even those such items are not included in schedule of
quantities.
40. If in any case work is required to be abandoned , the contractor shall not be entitled
for any claims and he will be paid as per the actual work done till that period.
41. Decision of the Bank shall be final and binding on any matter connected with the
work. The matter of any dispute shall be decided after mutual discussions based on
the terms and conditions of this contract. However, if the matter can not be resolved
then the same shall be referred to the respected qualified person agreed to both the
parties and his opinion shall be binding on both the parties. However, this is
precourse to any legal action in this regard.
42. If at any stage during the progress of work , it is observed that the contractor is not
progressing the work with due diligence , care of lagging much behind the schedule
or fails to gear up the work despite instructions from Bank’s Architect ,the Employer
(Bank ) reserves the right to terminate the contract with 7 days notice .In such case
the contractor shall be liable to pay the Employer to pay any extra cost involved for
the completion of the said work and will not obstruct any way in completing the work
through other agency. After completion of entire work the contractor shall be paid for
the actual work executed by him at the quoted rates after deducting any claims ,
damages .In case of such termination the security deposit held by the Bank will be
forfeited.
43. Contractor shall follow all rules / regulations in force and should posses the license
for employing labour and also follow all safety measures , labour bye laws and shall
be responsible for any lapse.
44. At any stage i.e. during the execution of work, any kind of change reqd. whether it is
in design or specification the same has to be in – corporated by the contractor.
45. Retention money i.e. 5% from final bill shall be retained for one year from the date of
completion of furnishing work.
46. Contractors should note that under no circumstances, the final amount of work should
exceed the sanctioned amount. Any additional expenditure over and above the
sanctioned work or any deviation of work will not be sanctioned.
47. Contractors should give an undertaking to the bank that work will be carried out as
per the specifications and quality of work; workmanship and material used shall be of
best quality.
48. Part payment of running bill shall be made in stages after inspection of work by
architect and concerned branch manager.
49. Final payment shall be released only after getting the clearance from the head office,
Allahabad bank.
50. Applicable TDS shall be deducted from the payments as per the govt. rules.
51. The contractors shall execute the work in co ordination with the architect and
concerned branch manager.
52. The successful contractor shall submit three sets of stamp papers to our consulting
architects M/S ATWAL & ASSOCIATES, Chandigarh for entering into an agreement
with our branch manager……….
CONTRACTOR ARCHITECT ALLAHABAD BANK
TENDER FOR ALLAHABAD BANK E- LOBBY AT PHASE -9 BRANCH, MOHALI .
SPECIFICATIONS / BRANDS / MAKE OF ITEMS TO BE USED.
DESCRIPTION BRANDa) Board / Ply : Commercial Board,
b) Laminate 1mm th. : Archidlam, Decolam, Formica, Greenlam
Century, URO. Sundek, Viagro
(As per approved shade)
c) Door Closer / Floor spring : Everite, Doorking, Sandhu ISI Marked.
d) Drawer & keyboard, Slide : Earl Bihari, Ebco Rails
e) Glue for fixing commercial : Fevicol (pidilite) Board / Laminate
f) Glass : Modi Float, Saint Gobain
g) Mortice Latch & Lock : Godrej, Harrison, Plaza
h) Vertical Blinds : Vista Levolor / Mac.
i) Tapestry / leather foam : Harmony, Vimal, Bhor
j) Aluminium Sections : Jindal / Mahavir / Hindalco
k) False Ceiling : Gypsum marked “Gypsteel “
l) Synthetic Enamel : Asian, Nerolac, ICI
m) Emulsion paint /Plastic paint : Asian, Nerolac, ICI
n) MCBs : MDS make only
o) DB’s : MDS make only
p) Switch & Socket : MDS / North-West (Modular)
q) Pipe (PVC) : Uniplast, DiPlast, AKG
r) Telephone Cable : Delton
s) Wires : Havells, R.R.Kabels, Plaza, Bonton
t) Cables : Grandley, ICC, R.R.Kabels Bonton
u) Fans : Khaitan, Orient, Havells
v) Mirror Optics : Philips, C & S, Wipro
w) Spot light & light fittings : Philips, C & S, Wipro
CONTRACTOR ARCHITECT ALLAHABAD BANK
TENDER OF BILL OF QUANTITIES FOR ALLAHABAD BANK E-LOBBY AT PHASE-9 BRANCH , MOHALI.
Sr.
No.
Description of Item Qty Rate Amount
1). Dismantling the existing brickwork along with other item if any & disposing of the debris at the place earmarked by local authorities after stacking useable material as directed including all incidentals etc. complete.
105 Cu.ft.
2). Providing & constructing 9” thk. Brick work using class 75 designation bricks in CM (1:6) for walls including all incidentals etc. complete.
130 Cu.ft.
3.) Providing & applying cement plaster to brick walls CM (1:6) to match with the existing all incidentals etc. complete.
345 Sq.ft.
4.) Providing & laying RCC ( 1:1.5 : 3 ) for lintel over main entrance door of ATM center at 7’ feet level with reinforcement of 12 mm dia tor steel /TMT bars ( four on bottom & two on top ) & stirrups of 8 mm dia 6” C / C including all incidentals etc. complete. ( lintel beam size 230 mm X 150 mm )
1 Cu.ft.
5.) Providing & applying Plaster of Paris (Maximum 1.5 mm thick) on plastered walls facing branch to provide smooth surface including all incidentals etc. Complete.
350 Sq.ft.
6.) Providing, fabricating & fixing in position fully glazed partition (front side) in 150 mm X 50 mm size teak wood frame all around with 12mm thick clear glass (Modi / Saint Gobin) with itching as directed including fixing the frame to brick Wall/ RCC/ wooden surfaces with necessary fasteners to have proper fixity including all incidentals etc. complete & providing polishing for teakwood surfaces to give nice finish.
30 Sq.ft.
7.) Providing , fabricating & fixing in position fully glazed single shutter ATM entrance door made out of teak wood rail size of 100 X 50 mm for top rail 125 X 50 mm for side rails ( two nos. ) and bottom rail of 150 mm X 50 mm with 12mm clear glass ( Modi/ Saint Gobin make ) with necessary itching as directed . Glass to fix in the grooves of the teak wood frame with necessary materials /beading etc. The job also includes cost of providing & fixing heavy duty hydraulic floor spring ( ISI mark ) in the floor fixing the door on heavy duty hydraulic floor spring & necessary fixing materials on the lintel bottom , handles, bolts , locks etc. of approved design including all incidentals etc. complete to have smooth functioning with the card reader . The exposed teak wood surfaces to be polished to give a nice finish.
NIL( Existing door to be retained )
8.) Providing, fabricating & fixing access card reader pillar box of size 9” X9” in 19 mm thick phenol formaldehyde bonded ply with 1 mm laminate finish of approved shade / finish as per the colour scheme including all incidentals etc. complete. Quoted rates shall include all necessary materials, accessories & labour and also allow provisions for electrical/ telephone / computer wiring /conduits & switch boxes etc (materials for wiring / conduits & switch boxes shall be separately paid for).
NIL( Existing pillar to be retained )
9.) Providing, fabricating & fixing in position full ht. Partition for UPS room made out of 2” X2” first class partal wood frame work at 2’ c/c in both directions properly fixed to walls , floor & ceiling & 6 mm thick phenol
35 Sq.ft.
formaldehyde bonded ply to both faces of frame in the pattern as directed . The area on the UPS room side to the finished with two coats of plastic paint of approved make / shade over a coat of primer to give an even finish and the surface on the customer lobby side to be fixed with 1 mm laminate finish of approved make /shade as per the colour scheme including all incidentals etc. complete as directed . Allow for 100 mm high 6mm thick beach wood skirting . The fixing of ply and laminate to be as per the pattern approved by bank . Quoted rates shall include all necessary materials , accessories & labour and also allow provisions for electrical / telephone / computer wiring conduits and switch boxes etc ( materials for wiring / conduits & switch boxes shall be separately paid for ).Provision to be made for shelves for placing UPS , batteries , VSAT indoor unit etc. complete in all respects .
10.) Providing & fixing powder coated louvered supply air grills 150 mm deep in the above partition for allowing air – conditioned air to the back room from the customer lobby including all incidentals etc. complete.
6 Rft.
11 )
Providing , fabricating & fixing in position matching door shutter of size 2’-6” X 7’ in the above partition made out of first class hardwood/partal wood shutter rails with top rail ,middle rail , bottom rail & side rail of sizes 150mm X 25 mm duly painted with anti-termite treatment and covered with 6 mm thick phenol formaldehyde bonded ply with paint & laminate as per the pattern / details in the ( partition ) including the brass hinges , mortise lock . Aluminum handles etc including all incidentals etc complete. Rate to include of providing suitable frame for the above door for proper fixity of the door shutter.
18 Sq.ft.
12 ) LOW HT. WOODEN PARTITIONS :-Providing and fixing wooden partitions of height 4’-6” , made of 2” X 2” partal wood frame @ 2’0” c/c vertically & horizontally .The bottom member shall be of partal wood of size 2” x 4” . The partal wood frame should be fixed rigidly at floor level. The frame work to be cladded with 6 mm thick ( I.S.I Marked ) phenol bonded boiling water proof commercial ply & then with 1 mm thk. Laminate with horizontal pin grooves. The rate of partition shall include complete hardware required. 5mm glass with etching design is fitted as per drg. /design. All exposed surface to be laminate finished. All
30 Sq.ft.
exposed edges shall be finished with teakwood beading. Size :- Length X Ht.
13.) Providing, fabricating & fixing wall paneling in customer lobby by 50 mm X 25 mm first class hard wood/partal wood frame work at 600mm c/c both ways with anti- termite treatment for the wood work with 6 mm thick phenol formaldehyde bonded ply covered with 1 mm laminate finish of approved shade / finish as per the colour scheme including all incidentals etc complete as directed. Allow for 100 mm high 6 mm thick steam beach wood skirting. The fixing of ply & laminate to be as per the pattern approved by bank. Quoted rates shall include all necessary materials, accessories & labour & also allow provisions for electrical /telephone / computer wiring conduits & switch boxes etc. (materials for wiring / conduits & switch boxes shall be separately paid for).
270 Sqft.
14.) Providing, fabricating & erecting suspended false ceiling using GI frame work & 12.5 mm thick gypsum board & painting with two coats of plastic emulsion paint over a coat of plastic emulsion paint over a coat of primer including making necessary cut outs etc. for light fitting etc. complete .The details of the job shall be as per manufactures specification i.e. , of M/S Gypsum board . Their specification no. GS- MFSC - 4.1 is applicable for the job.
140 Sqft.
15.) Providing & fixing polished steam beach wood moulding (out of 65 X 65 mm sections) at junctions of false ceiling including polishing etc. complete.
65 Rft.
16.) Providing & laying ( min .) 8 mm thick vitrified ceramic tiles of approved size & design / shade in customer lobby , entrance steps & backroom, fixed on the existing floor with chemical adhesive “ Fevimate “ of pidilite or similar approved adhesive of adequate thickness to suit the required level including preparing the existing surface as necessary with necessary incidental requisite materials all complete as per direction.
150 Sq.ft.
17.) Providing table for V-sat IDU of size 850mmX600mm X 750mm size made out of 19mm phenol formaldehyde bonded ply with three drawer & laminate finish & fitting such as knobs, handles ,locks etc. & other incidentals etc. complete .
NIL ( To be accommodated in UPS area )
18.) Providing & erecting 19mm thick granite cladding of approved shade for the outside walls upto lintel level in CM mortar 1:3
80 Sq.ft
backing & cement slurry & other fixing materials etc. & finishing the joints with necessary matching pigments etc. & all other incidentals etc. complete.
19) Supplying & fixing rolling shutter of approved make made out of 80 X 1.25 mm size MS laths interlocked together their length & jointed together at the end by end locks mounted on specially designed pipe shaft with brackets , side guides & arrangement for inside & outside locking with push & pull operation complete including the cost of providing & fixing necessary 27.5 cm long wire spring grade no 2 & ms top cover of required thickness for rolling shutter & all incidental material etc. complete.
55 Sq.ft
20) Providing, fabricating & fixing wooden cover box to cover the rolling shutter box using 12 mm phenol formaldehyde bonded & water proof ply with necessary first class partal wood frame work in 50mm X 50 mm for the bottom & two sides of the shutter box duly treated with anti-termite paint & finished with plastic emulsion paint of two coats to give a nice finish over a coat of primer. Rate to include making provision of fixing spot light & also openable bottom shutter with hinges for servicing the rolling shutter shaft & all other necessary materials as required etc. complete.
17 Sq.ft.( Only Front area to be measured for payment )
21 ) Providing & applying two coats of plastic emulsion paint on walls facing branch of approved ,make & shade over a coat of primer after necessary surface preparation etc. complete
170 Sq.ft.
22 ) STEEL DOOR :- Supply , fabrication & fixing of M.S. door using 35 mm X 35 mm X 5 angle frame & 25 mm X 25 mm X 3 angle members including bracings with 16 gauge M.S. sheet stitch welded to door shutter frame complete including painting with 2 coats of red-oxide primer two coats of synthetic enamel paint , handle , stay arrangement , tower bolt , aldrop locking system on both sides etc. Including making provision in the wall for door fixing, complete job.
21 Sq.ft.
TOTAL COST OF FURNISHING
ELECTRICALSr. No.
Description of Item Qty Rate Amount
1.) Supply & fixing of 63 A switch fuse unit with rewirable fuse in sheet steel enclosure on MS angle frame /legs on wall at a suitable location as directed with interconnection
1 No.
mending good damages to original finish painting etc. As required including all incidentals etc. Complete.
2.) POINT WIRING Point wiring with 1100 V grade 3 nos. single core 1.5 Sqmm. ( 1 for phase . 1 for common neutral – black colour & 1 – green colour for common earth by looping method ) PVC insulated flexible FRLS copper conductor cable through suitable size rigid PVC pipe complete with junction box , circular box, elbows , bends ,couplers & other accessories on surface , above false ceiling or concealed by chase cutting on wall from light & fan switch board to light . Light & 6 A socket outlet on the same switch board or separately mounted switch board.The work includes supply & fixing of all material such as north west /MK India / Woods or equivalent make modular type 6A switch, 3 plate ceiling rose / angle or batten holder etc as required. Rate for the point wiring also include circuit wiring with 1100 V grade 2 nos. Single core 2.5 Sqmm ( 1 for phase & 1 ( black colour for neutral )+ 1 no. 1.5 Sqmm ( green colour for earth) PVC insulated FRLS copper conductor cable through suitable rigid PVC pipe as described above from DB to switch board , interconnection, mending good all damages to original finish, painting etc. as required to be completed all respects .
a) Light points ( All Types ) 6 Nos.b) Wall bracket point with supply & fixing 6 A
sockets near fan & controlling switch at light / fan switch board.
__
c) 1 X 6 A 3 pin socket with switch on separate switch board other than light switch board.
2 Nos.
d) Same as in C but on switch board itself. 2 Nos.3) AC POWER POINT WIRING
A.C. Power Point wiring from lighting / power DB with 1100 volt grade 2 Nos. Single core 4 Sqmm. + 1 no. 2.5 Sqmm ( green colour for earthing ) PVC insulated flexible FRLS copper conductor cable through suitable size rigid PVC conduits complete with junction box , circular box, elbows , bends , couplers & other accessories on surface , above false ceiling or concealed by chase cutting on wall surfaces complete with north west / woods/MK – India or equivalent modular type 25 A socket , 25 A starter, indicator, mounting box & front plate, interconnection , mending good old damages to original finish painting etc as required , including all incidentals etc. complete.
2 Nos.
4.) Same as above in AC point wiring but with 6 A / 16 A switch & socket outlet & indicators etc. instead of starter for vacuum cleaner point, sign board point & ATM machine raw power including all incidental materials etc. complete.
__
5.)a) Same as above in item no. 4 for ATM / other machine points , Switch / Hub, VSAT IDU , ACCESS LOCK , SIGN BOARD ETC. ( wiring to provided from ATM / UPS Switch board)
8 Nos.
b) Point wiring for one light in customer lobby + one tube light in signboard to be controlled by one switch (emergency light point). Wiring as per specifications in item no. 2 but power supply shall be from UPS DB.
2 No.
6.) INDUSTRIAL TYPE SOCKET / PLUG Supply , installation , testing & commission of 32 A 3 pin socket with matching plug & 32 A SP controlling MCB for incoming & outgoing power supply connection of UPS with MS enclosure as supplied by manufacturers & including all incidentals etc. complete.( to be installed only if required after confirmation from manager )
2 Set
7.) ATM / UPS DISTRIBUTION BOARD ( FOR UPS POWER SUPPLY ) Supply , installation , testing & commissioning approved make distribution board with MCB having breaking capacity of 10 KA or RCBO of 300 ma sensitivity complete with bus bar interconnection , painting , mounted on flat iron frame on wall/ flushed with finished wall by chase cutting , mending good to original finish painting etc. as required . RCBO should have overload, short circuit & earth leakage protection.SPN 8 way consumer unit MCB DB with bus bar & the following RCBO / MCBS:INCOMING:! no. 240 V 32 A DP RCBO/ ELCB ( 300 ma sensitivity )OUTGOING : 8 no. 240 V 10 A / 16A /32 A MCB.
Nil( Branch Distribution Board to be used )
8.) LIGHTING / POWER DISTRIBUTION BOARD :- specifications same as in item 7 above except the item of incoming MCB which is to be 32 A DP MCB instead of RCCB/ ELCB
1 no
9) Providing & laying Sub main wiring from main switch to lighting / power & ATM / UPS Distribution boards with 1100 V grade single core 2 nos. 10 Sqmm ( phase & neutral ) + 4 Sqmm ( earth ) PVC insulated FRLS copper wire through suitable size rigid PVC conduit
80 R.ft.
pipe with junction box , elbows ,bends & other accessories on surface , above false ceiling or concealed by chase cutting on wall as per site condition , mending all damages to original finish interconnection, painting etc as required to be completed in all respects including all incidentals etc. complete. Wiring to connect Branch Distribution Board to E- Lobby Distribution board
10 Supply, installation, testing & commissioning of light fitting of Wipro make model no. WCP 64236 fusion –recess mounted direct indirect down light luminar with 2X 36 W CFL lamps or equivalent of reputed brand in customer lobby with connection etc complete including all incidental etc complete.
3 Nos.
11 Supply, installation, testing & commissioning of WIPRO make Galaxy recessed CFL down lighter with satin finish reflector model no. WCP 42118 with 1X18 W CFL lamp in UPS Room (1 Nos.) & rolling shutter box (2 Nos.) or equivalent of reputed brand including all incidentals complete.
3 Nos
12 Supply ,installation, testing & commissioning of WIPRO make light fitting model no.WCF 16120 Optima – slim channel with 1X36/40 W tube light ( surface mounted fitting) with lamp directly on wall / ceiling including 2 nos. wooden round block properly polished & necessary interconnection between light points & fitting with 1.5 sqmm copper PVC insulated copper wire etc complete.
2 Nos.
13.) Supply & fixing on wall / furniture / partition recessed type telephone socket outlet ( RJ 11) with mounting box & front plate with chase cutting mending good etc. as required complete .
2 Nos.
14 ) Supply & fixing on wall / furniture / partition recessed type computer data socket outlet ( RJ 45) with mounting box & front plate with chase cutting mending good etc. as required complete including data cable from branch to each outlet for plugging various machines .
7 Nos.
15 ) Supply & laying 25 mm dia heavy duty rigid PVC conduit complete with junction box , circular box , elbows, bends , couplers & other accessories as required by chase cutting on wall through partition or over false ceiling making good to all damages to original finish, painting etc. as required .
30 Rft.
16 ) Earthing ( one each for ATM machine & UPS )Earthing the installation as per I.E. rules conforming to IS: 3043 or its latest amendment by making earth station with
2 nos.
600mm X600mm X 3mm thick copper plate which is to be installed such as its top edge shall be at minimum depth of 3 m below ground level after preparation of pit with charcoal & salt & 50 mm dia partly perforated GI pipe with funnel for watering arrangement all incidental material etc complete. The earthing installation should be provided with 300mm x 300mm X 300mm masonry inspection pit with CI hinged cover having locking arrangement etc. complete. The earth installation should be tested after commissioning the system & the same should be well within the standard limits.
17) Providing & fixing 25mm X 6mm copper earth lead in strip with PVC sleeved / insulated on wall surfaces with tinned copper bar saddles / clamps at 300 mm including incidental material s etc. complete.
40 Rft.
C. AIR -CONDITIONER
18) ROOM AIR CONDITIONER Supply, standard installation including hardwood frame work etc testing & commissioning of window air conditioner with inbuilt timer including all incidentals etc. complete. AC must be of latest technology & reputed brand having good local set up for providing best post installation maintenance services. Rate quoted to include all kinds of taxes etc complete.
a. 1.00 TR window A.C.b. 1.5 TR window A.C.
Nil
19) Providing & fixing MS cage for the above air-conditioning machines in 12 mm square bars at 150 mm c/c both ways including two coats of enamel painting over a coat of primer etc. including all incidentals etc. complete.
Nil
20 ) SPLIT AIR CONDITIONERSupply , standard installation, testing & commissioning of split air – conditioner of 1.5 ton with inbuilt timer standard accessories such as drain pipe ( 5M) , refrigerant copper pipe 5m, interconnecting electrical cables , MS bracket duly painted for compressor / outdoor unit & connected civil works & including all incidental etc. complete. AC must be of latest technology & reputed brand having good local set up for providing post installation maintenance services. Rate quoted to include all kinds of taxes etc complete.
2 Nos.
21 ) Providing & fixing MS cage for outdoor unit of the above air conditioning machines in 12 mm square bars at 150mm c/c both ways
2 Nos.
including two coats of enamel painting over a coat of primer etc. including all incidentals etc. complete & locking arrangement for the cage.TOTAL ( ELECTRICAL WORKS )
In Words:-Cost of Furnishing : - Rs.
Cost of Electrical work : - Rs.
GRAND TOTAL : - Rs.
Address of contractor Signature of contractor