template v1.0 last updated 01/09/14 … · system tread tack board top of ... general contractor...
TRANSCRIPT
Acoustic Ceiling Panel/Tile
Batt Insulation
Blocking
Concrete
Continuous Framing
Earth Compacted Fill
Glass
Gravel
Gypsum Board
Masonry, Brick
Masonry, CMU
Rigid Thermal Insulation
Sheathing
Steel
1A101
SIM
1A101
SIM
1A101
SIMBuilding SectionDetail No.
Sheet No.
Reference Label
Detail No.Sheet No.
Reference Label
Detail No.Sheet No.
Reference Label
Room No.Room Area
Door/Room No.
InsulationPartition Configuration
Partition Configuration
Key Note No.
ALIGN
Wall Section
Detail Section/Callout
Room Tag
Door Tag
Partition Tag
Key Note
Aligned Surfaces
Room Name101
150 SF
Room Name
101
AreaArea Tag
Area NameArea Name150 SF
F 1 a
Scope of ProjectProject Limit Line
Grid No.
Centerline
Column Grid Line
Spot Elevation
Elevation
Spot Elevation AFF
Level/Datum Elevation AFFLevel Marker
Level/Datum Name
Window Type Window Type Tag1t
CL
Highpoint @ Tail Slope Indicator
Change @ Head Material Change Indicator
Starting Point @ Center Dimension Crosshair
North Arrow
Reference LabelGraphic North
NameElevation
0
Xx.x
Xx.x
Sheet No.
Detail No.
168421 3 65 7 12109 11 1413 15
8421 3 65 7 12109 11 1413 15 16
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
Checked by
These drawings/specifications are the property of Oculus Inc. They are furnished as contract documents only. The seal(s) and
signature(s) apply only to the document to which they are affixed, and expressly disclaim any responsibility for all other plans,
specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the
architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any type of warranty or certification relating to the performance of products and materials
beyond those provided by their respective manufacturer. © 2016 Oculus Inc.
of
Drawn by
Issue Date
Project #
Scale
Client Approval
Temp
late
V1.0
Las
t Upd
ated
01/
09/1
4
ONE
SOUT
H ME
MORI
AL D
RIVE
| SUI
TE 15
00 | S
T.LO
UIS,
MO
6310
2(3
14)3
67-6
100
As indicated
1/4/20
17 12
:41:42
PM
MMP
MMP
01/04/2017
17516-OH23
A0.1
General ProjectInformation
Preliminary - Not ForConstruction
Piqu
a, OH
1260
Ash
Stre
et,Pi
qua,
OH 45
356
Piqu
a, OH
DES1
(Whi
tesp
ace)
Sheet Number Sheet Name Drawn By Checked ByCurrentRevision
CurrentRevision
Date
A0.1 General Project Information MMP MMPA2.1 Floor Plan MMP MMPA3.1 Reflected Ceiling Plan MMP MMPA6.1 Interior Elevations MMP MMPR1.1 Reference Plans MMP MMP
General Project Notes
Automatic Air VentAnchor BoltAboveAir ConditioningAccessAcousticalAcoustical PlasterAcoustical Ceiling Tile Acoustical Ceiling PanelAccess DoorAddendumAdhesiveAdjustableAdjacentAbove Finished FloorAir Handling UnitAlternateAluminumAluminumAnchor, AnchorageAnodizedAccess PanelApproximateArchitect (ural)AsbestosAsphaltAsphalt TileAuxiliaryBottom of DeckBath AccessoryBulletin BoardBoardBelowBetweenBeveledBituminousBuildingBlockBlockingBeamBottomBearingBearing PlateBrickBoth SidesBasementBuilt Up RoofingBoth WaysConduitCabinetCatch BasinChalkboardCenter to CenterClosed Circuit TelevisionCementCeramicCounter-flashingCorner GuardCircumferenceConstruction JointCalk (ing)CeilingClosetClear (ance)ClosureConcrete Masonry UnitClean OutCarpet (Ing)ColumnCompress (Ed),(Ion),(Ible)ConcreteConnectionConstructionContinuous or ContinueContract (or)CorridorCard ReaderCathode Ray TubeCeramic TileCounterCountersink
DeepDouble FacingDemolish, DemolitionDetailDepressedDrinking FountainDiameterDiagonalDimensionDivisionDead LoadDemountableDowDamp ProofingDamperDoorDownspoutDumbwaiterDrawingDrawerEachAcoustical Tile (Exist to Remain)Expansion BoltExisting Exposed ConstructionExterior GradeExpansion JointElevationElectric (al)ElevatorEmergencyElectrical Metallic TubingEnamelEntranceEqualEquipmentEstimateElectric Water CoolerExhaust FanExhaustExteriorExistingExposedFire AlarmFabricFasten, FastenerFurnished by OthersFoundationFace of ConcreteFloor DrainFinished Floor/FaceFactory FinishFace of FinishFire ExtinguisherFire Extinguisher CabinetFiberglassFire Hose CabinetFire Hose StationFlathead Machine ScrewFlathead Wood ScrewFinish (ed)FluorescentFlashingFlexibleFace of MasonryFireproofingFire ResistantFace of StudsFull SizeFeetFootingFurred (ing)Face of BrickGage, GaugeGalvanizedGrab BarGeneral Contractor (or)Ground Fault InterruptGlass, GlazingGravelGypsum Wall BoardGypsumGypsum Board
Hose BibbHollow CoreHardwareHook (s)Hollow MetalHorizontalHigh PointHandrailHeightHeatingHeating/Ventilating/ACHot Water HeaterInside DiameterInside FaceInclude (d), (ing)InformationInsulate (d), (ion)InteriorInvertJunction BoxJanitor's ClosetJointKeene's Cement PlasterKitchenKnockoutKick plateLongLaboratoryLaminate (d)LavatoryPoundLive LoadLow PointLightLouverMaintenanceMasonryMaterial (s)MaximumMetal Corner BeadMechanic (al)MediumMetalManufacture (er)MinimumMirrorMiscellaneousMasonry OpeningMullionNot ApplicableNot In ContractNominalNoise Reduction CoefficientNot To ScaleOverallOn Center (s)Opposite HandOutside DiameterOverheadOpeningOppositePaint (New)Prefabricate (d)Pre-finishedPlatePlastic LaminatePlasterPlywoodPressed MetalPanic BarPolishedPropertyPreservative TreatedPainted PartitionPaper Towel ReceptorPolyvinyl ChlorideQuarry Tile
RiserReturn AirRadiusResilient BaseRoof DrainRoof Drain ConductorReferenceReflect (ed),(ive),(or)ReinforcementRequiredRevision (s), RevisedRoofingRoomRough OpeningSinkScheduleStructural Clay TileSimilarStandardSectionSafety GlassSealantSquareStainless SteelStationStandardSeatingSteelStorageStructuralSuspendedSymmetry (ical)SystemTreadTack BoardTop of CurbTelephoneTerrazzoTongue And GrooveThresholdThick (ness)Tack StripTowel BarTop ofToleranceTop of SteelToilet Paper DispenserToilet PartitionTop of SlabTransparent Finish-StainedTelevisionTop of WallTypicalUnfinishedUnless Otherwise NotedUrinalVentVinyl BaseVinyl Composition TileVerticalVinylVapor BarrierVinyl TileVinyl Wall FabricWithWood BaseWater ClosetWoodWired GlassWindowWire Mesh PartitionWithoutWeatherproofWeatherproofingWorking PointWainscotWelded Wire MeshTransformer
AAVABABVACACCACOUSACPLACTACPADADDADHADJADJCAFFAHUALTALALUMANCANODAPAPPROXARCHASBASPHATAUXB/DBACCBBDBDBELBETBEVBITBLDGBLKBLKGBMBOTBRGBRG PLBRKBSBSMTBURBWCCABCA. BA.C.B.CCCCTVCEM.CERCFLCGCIRCCJCKCLGCLOSCLRCLSCMUCOCPTCOLCOMPCONCCONNCONSTCONTCONTRCORRC.R.CRTCTCTRCTSK
DDADEMDETDEPRDFDIADIAGDIMDIVDLDMTDNDPDPRDRDSDWDWGDWREAEACTEBEECEGEJELELECELEVEMERGEMTENAMENTEQEQUIPESTEWCEXFEXHEXTEXTG.EXPFAFABFASFBOFDNF/CONCFDFFFFHF/FINFEFECFGLFHCFHSFHMSFHWSFINFLFLASHFLXF/MASFPRFGFRFSFSZFTFTGFURRFoBGAGALVGBGCGFIGLGVLGWBGYPGYP.BD.
HBHCHDREHKHMHORIZHPHRHTHTGHVACHWHIDIFINCLINFOINSULINTINVJBOXJCJTKCPLKITKOKPL LABLAMLAVLBLLLPLTLVRMAINTMASMATMAXMCBMECHMEDMTLMFRMIN MIRMISCMOMULLN/ANICNOMNRCNTSOAO.C.O.H.ODOHDOPNGOPPPPFBPFNPLPLAMPLASPLY.PMPNBPOLPROPPRTPTDPTNPTRPVCQT
RRARADRBRDRDCREFREFLREINFREQDREVRFGRMROSSCHSCTSIMSTDSECTSFGLSNTSQSSSTASTDSTGSTLSTOSTRUCTSUSPSYMSYSTTBTCTELTERRT>HTHKTKSTLBTOTOLT.O.S.TPDTPTNT/STSTVTWTYPUNFUONURVVBVCTVERTVINVPBVTVWFW/WBWCWDWGWINWMPW/OWPWPFWPTWSCTWWMXFMR
1) The Architect shall be notified immediately of any discrepancies between these documents and any applicable codes by the agent involved withthe governing agency having jurisdiction. It is understood that the "field inspector" for such agency has final authority to approve/disapproveproject construction and correctness of all code related items.
2) Each subcontractor is considered a specialist in their respective field or trade and shall notify, prior to performance of the work, the GeneralContractor and the Architect of any work called out in the drawings which cannot be fully guaranteed or constructed as designed or detailed.
3) The Contractor shall verify all site conditions and dimensions prior to commencing the work and immediately notify the Architect in writing of anydiscrepancies.
4) The Contractor shall verify all dimensions and locations of all openings, bases, and special provisions required for equipment, ducts, piping,conduits, finish hardware, etc. And immediately notify the Architect in writing of any discrepancies.
5) Do not scale drawings. All dimensions specified shall govern.6) Where construction details are not shown or noted for any part of the work, detailing shall be the same as for other similar first class work for the
trade involved. The Architect shall be notified immediately of any alternate non-standard or untested method(s) proposed.7) General Contractor shall coordinate architectural drawings with mechanical and electrical, plumbing, civil and landscape drawings.8) General Contractor shall maintain all existing fire ratings during demolition and construction.
Item
FurnishedBy Installed By
Exist
ing
CommentsGC Land
lord
AT&T
Deale
rGC La
ndlor
dAT
&TDe
aler
ArchitecturalCARPET ● ● Sales Floor onlyCEILING GRID ● ● Sales Floor onlyCEILING TILE ● ● Sales Floor onlyLIGHT FIXTURES ● ● Sales Floor onlyMUSIC ● ●QMI CABINET (ONE) ● ●SALES FIXTURES ● ●SHOPPERTRAK ● ●
CommunicationsAATV IT EQUIPMENT & WI-FI ● ●DSL OR T-1 SERVICE ● ●IT EQUIP. NOT LISTED ABOVE ● ●
SignageEXTERIOR SIGNAGE ● ●
AT&T STORE
Patricia [email protected]
Architect Design Consultant:Oculus Inc.One S. Memorial Dr. Suite 1500St. Louis, MO 63102
Morgan [email protected](314) 367-6100 phone(314) 367-1489 fax
Light Fixture Orders:GraingerAndrew Dodson(404) [email protected]
Carpet Orders:ShawMark Law(770) [email protected]
HVAC Ordering: (if applicable)Trane National AccountsEd Metzger(404) [email protected]
AT&T STORE
NOTE: THESE DOCUMENTS CONTAIN INFORMATION PERTAINING TO THE ARCHITECTURAL SCOPE OF WORK ONLY. FOR THIS PROJECT ENGINEERING DESIGN, DOCUMENT AND SPECIFICATION PREPARATION, AS REQUIRED FOR ALL OTHER DISCIPLINES, HAVE BEEN PREPARED BY OTHERS AND ARE NOT THE RESPONSIBILITY OF THE ARCHITECT/OCULUS INC. INFORMATION INDICATED ON THESE DRAWINGS/DOCUMENTS SHOWING OR REFERENCING MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION INFORMATION WHERE IT OCCURS HAS BEEN PROVIDED AS REFERENCE INFORMATION AND IS FOR DESIGN COORDINATION PURPOSES ONLY. THE ENGINEERING DESIGNERS, AS LICENSED AND QUALIFIED PROFESSIONALS, UNDER CONTRACT TO OTHERS, SHALL REMAIN SOLELY RESPONSIBLE FOR ALL DESIGN AND APPLICABLE CODE COMPLIANCE MATTERS RELATIVE TO THEIR RESPECTIVE DISCIPLINES. THIS SHALL INCLUDE ADDRESSING AND RESOLVING ANY PLAN REVIEW COMMENTS RELATIVE TO THEIR SPECIFIC SCOPE OF WORK. THE PROJECT ENGINEERING DESIGNERS SHALL ENDEAVOR TO BRING TO THE ATTENTION OF THE ARCHITECT/OCULUS INC. ANY DESIGN CHANGE OR CODE COMPLIANCE ITEMS IMPACTING THE ARCHITECTURAL SCOPE OF WORK AS EXPEDITIOUSLY AS POSSIBLE.
AT&T Contact:CBRE Construction Manager
# Description Date
FOR DESIGN INTENT
REFERENCE ONLY
BUILDING KEY PLAN (NTS)MATERIALS LEGEND (NTS)LIST OF COMMON ABBREVIATIONS
RESPONSIBILITY SCHEDULE DRAWING INDEXSYMBOLS LEGEND (NTS)
LOCATION MAP (NTS)PROJECT DIRECTORY
FOR DESIG
N INTENT O
NLY
Rotate carpet tile pattern direction 90 degrees from adjacent as indicated,
TYP.
PROJECT LIMIT LINE
PROJ
ECT
LIMIT
LINE
L14A2.1
L14A2.1
MW
U-D
AATV
-IL4
AATVBENCH
MWU-GRAPHICMWU-GRAPHICMWU-GRAPHICMWU-GRAPHICMWU-GRAPHICWINB
WINB
IP-DMWU-D MWU-D
ACC-12'MWU-D MWU-D MWU-D
MPOS
ADA-MPOS
LT-S
LN-TBL
LT-S
LT-S
LN-TBL
LT-S
CT-OM FSLS
7' - 4" 7' - 7" 5' - 0" 6" 5' - 0" 1" 2' - 0" 5' - 0" 1' - 0" 5' - 0" 2' - 7" 5' - 0" 4' - 11"
15' -
9 3/4"
5' - 1
0 5/8"
7' - 3
7/8"
1' - 7" 4' - 10" 1' - 0" 5' - 0" 1' - 0" 5' - 0" 1' - 0" 6' - 1" 6' - 1" 1' - 0" 5' - 0" 1' - 0" 5' - 0" 1' - 0" 5' - 0" 1' - 5" 7' - 4 7/8"
7' - 1
0 1/2"
3' - 0
"3 3
/8"4'
- 7 7/
8"4'
- 7 7/
8"1'
- 0"
5' - 0
"2'
- 6 5/
8"
iPhone iPad SP&T2 PROT PERS POWER
SP&T1 SP&T3 SP&T4 ACC-VALU
VALU
DL/
WH
P
LT-S-ADA
ADA-LN-TBL
LT-S-ADA
6' - 8"
705 SF
Work/Break Area102
35 SF
Hallway104
50 SF
Restroom103
1492 SF
Sales Floor101
CPT-1
CPT-3
6' - 0" 6' - 0"
7' - 9
"
0707
4' - 0"
6' - 0
"25' - 6" 25' - 6"
51' - 0" 28' - 0 1/4" VIF
5' - 4
7/8"
7' - 1
0 3/4"
09
08 08
08
08080808
08
090909
64
7' - 0" 7' - 0"
CL
CL
01
32
32
35 35 35
45
45
A6.1
C1
F1
J1
F7
103
102101
102A
Existing Wall to Remain
Existing Wall to Remove (Demo)
New Construction Wall
Existing Door to Remain
Existing Door Relocated
Existing Door to Remove (Demo)
New Construction Door
AFlush Door
KICKPLATE
F1: 2" HEAD
HOLLOW METAL KNOCK DOWN FRAME
ACP-1 USG Frost ClimaplusSize: 2' x 2'Number: #414Edge: SLBTile Color: Silvertone #052Grid: Donn DX 15/16"800-950-3839
CPT-1 ShawStyle: #4546VAT&T High Speed SquareColor: M5556 - Blue StreakConstruction: Pattern LoopInstallation: Quarter Turn770-241-1345
P-1E* Benjamin Moore"Wedding Veil"#2125-70ALT: SW 7006 "Extra White"Eggshell Finish
(White walls)
P-2E* Benjamin Moore"Sweet Innocence"#2125-50ALT: SW 6239 "Upward"Eggshell Finish(Light grey walls/sales floor column)
RB-1** ShawSize: 4"Style Number: #336VSColor: Gunmetal
P-1S* Benjamin Moore"Wedding Veil"#2125-70ALT: SW 7006 "Extra White"Semigloss Finish(White doors/frames)
P-4E* Benjamin Moore"Orange Burst"#2015-20ALT: SW 6886 "Invigorate"Eggshell Finish
CPT-3 ShawStyle: CO149 AT&T EntryColor: JB210 Jet Black24"x24" Multilevel LoopInstallation: Quarter TurnMark Law770-241-1345
P-4S* Benjamin Moore"Orange Burst"#2015-20ALT: SW 6886 "Invigorate"Semigloss Finish(Orange doors/frames)
NOTES: * Use ALT Sherwin Williams paint when Benjamin Moore paints are not available.** RB-1 is also available through Grainger, and Dealer can source directly from Grainger as needed. Contact Andy Dodson, 404-806-8263, [email protected]. Please copy [email protected]
HOLLOW METAL FRAME
JAMB ANCHOR CLIP (4 MIN. PER JAMB)
MTL. STUD - PROVIDE DBL STUDS AT OPENINGS W/ DOORS GREATER THAN
OR EQUAL TO 42" AND ALL TENANT ENTRY DOORS.
REFER TO PARTITION TYPE
HOLLOW METAL FRAME
DOOR AS SCHEDULED
1/2"
5/8"
2"
BOX BEAM HEADER
WALL FRAMING. REFERENCE PLAN FOR PARTITION TYPES.
Dimension Point
Top of Concrete
VCT Floor
Vinyl Edge Strip - Johnsonite CE-XX-A, Color: 63-Burnt Umber
Glue-down Carpet
Johnsonite MTC-00-A
Center on door where occurs
BCW AATV
ACCMWU
RB-1
RB-1
RB-1 RB-1
RB-1
RB-1
RUBBER BASE NOTES:
1. CONTRACTOR TO PROVIDE AND INSTALL CONTINUOUS RUBBER BASE, RB-1, ON ALL EXPOSED WALLS AND GYPSUM BOARD COLUMN SURROUNDS.
2. THE ONLY SALES AREA FIXTURES THAT RECEIVE RUBBER BASE, RB-1, ARE ACCESSORY WALL (ACC), BACKWRAP (BCW), AND AATV FIXTURES.
3. RUBBER BASE, RB-1, IS TO EXTEND CONTINUOUSLY BEHIND ACC, BCW, AND AATV FIXTURES.
168421 3 65 7 12109 11 1413 15
8421 3 65 7 12109 11 1413 15 16
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
Checked by
These drawings/specifications are the property of Oculus Inc. They are furnished as contract documents only. The seal(s) and
signature(s) apply only to the document to which they are affixed, and expressly disclaim any responsibility for all other plans,
specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the
architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any type of warranty or certification relating to the performance of products and materials
beyond those provided by their respective manufacturer. © 2016 Oculus Inc.
of
Drawn by
Issue Date
Project #
Scale
Client Approval
Temp
late
V1.0
Las
t Upd
ated
01/
09/1
4
ONE
SOUT
H ME
MORI
AL D
RIVE
| SUI
TE 15
00 | S
T.LO
UIS,
MO
6310
2(3
14) 3
67-6
100
As indicated
1/4/20
17 12
:41:49
PM
MMP
MMP
01/04/2017
17516-OH23
A2.1
Floor Plan
Preliminary - Not ForConstruction
Piqu
a, OH
1260
Ash
Stre
et,Pi
qua,
OH 45
356
Piqu
a, OH
DES1
(Whi
tesp
ace)
Sheet Notes
1/4" = 1'-0"L1 Floor Plan
AL-SFCOCGFF (D)FACTFGFR 45GGL-1HOHWMFRNCOOPPPNLPRPSPTPVCSSTLSTL-CCSTL-KDSTL-WTTCTSWDWD-HCWD-SC
ALUMINUM STOREFRONTCASED OPENINGCOILING GRILLEFLUSHFLUSH (DUTCH)FACTORYFULL GLASSFIRE RATING LABEL IN MINUTESGLASSGLAZING TYPEHOLD-OPENHARDWAREMANUFACTURER'S STANDARDNON-CASED OPENINGOPPOSITEPANELPAIRPOCKET SLIDEPAINTPOLYVINYL CHLORIDESMOKE CONTROL "S" LABELSTEELSTEEL COMPOSITE CORESTEEL KNOCK-DOWNSTEEL WELDEDTEMPERATURE RISE LABEL - DOORTRANSPARENT FINISH - CLEARTRANSPARENT FINISH - STAINEDWOODWOOD HOLLOW COREWOOD SOLID CORE
Key # Keynote Text01 All issues regarding the BOH facilities, including ADA, building codes,
materials, finishes, construction and engineering are the responsibility of thedealer and are outside the scope of work of these drawings.
07 Centerlines are used to layout store, including ceiling, Power/Data, Fixtures,etc. and must be marked and varified prior to start of construction. Contactarchitect immediately if there are dimensional discrepancies.
08 GC to paint wall P-4E to 8' - 0" AFF. Paint wall P-1E above 8' - 0" AFF. Seeelevation and finish legend for more information.
09 GC to paint wall P-1E. See elevation and finish legend for more information.32 Promotional poster rails provided by Fixture Vendor, promotional poster
provided by others.35 Light fixture above - see RCP for location and additional information45 GC to install rubber base (RB-1) @ bottom of fixture after being installed by
vendor. The front and sides of the backwrap fixture (BCW) shall receiveRB-1, and the front and sides of the AATV wall fixture (AATV) shall receiveRB-1.
64 Preferred location for main lighting switch bank. All interior lights to terminatehere. Dealer to verify & coordinate final location.
MarkDoor Frame
CommentsWidth Height Thickness Type Material Head Jamb Material Type101 6' - 0" 8' - 6" 1 3/4" Existing Existing Existing Existing Existing Existing102 3' - 0" 7' - 0" 1 3/4" A WD-SC S12/A2.1 S9/A2.1 STL-KD F1102A 4' - 0" 7' - 0" 1 3/4" Existing Existing Existing Existing Existing Existing103 3' - 0" 7' - 0" 1 3/4" A WD-SC S12/A2.1 S9/A2.1 STL-KD F1
• GC to install fire retardant blocking as required for all casework, shelving, countertops, & owner provided equipment.
• Patch concrete slab as required to repair conduit installation. See electrical for extend of slab trenching
• All dimensions are finish to finish unless noted otherwise.• Maintain existing fire ratings at tenant separation walls during demo/construction
activities.• See Interior Elevations on sheet A6.1 for all walls where no finish or base is
indicated.• Paint all Back of House (BOH) and Sales Floor doors and frames (aluminum
storefront not included) to match adjacent wall color, using a semi-gloss finish UON.
• All GWB columns, if applicable, are to be painted P-1E ("Wedding Veil" - eggshell finish).
• GC to provide rubber base as scheduled around the base of the AATV, Cashwrap, and Backwrap fixtures after they have been installed. Coordinate installation with Fixture Vendor.
• GC to coordinate all BOH work, including restrooms, finishes, power/data requirements, etc, with tenant prior to bid completion and is not included with this scope of work.
QTY Plan ID DescriptionFOIO1 AATV
BENCHAATV Bench
1 AATV-IL4 Inline 4 AATV Wall1 ADA-LN-TBL DES1 ADA Learning Table - NOT SUPPLIED BY FIXT. VENDOR1 ADA-MPOS Manager's Point of Sale (ADA)1 CT-OM Community Table with Opus Mobile1 IP-D 60" iPhone Fixture2 LN-TBL DES1 Learning Table - NOT SUPPLIED BY FIXT. VENDOR4 LT-S LT Stool - NOT SUPPLIED BY FIXT. VENDOR2 LT-S-ADA LT Stool ADA - NOT SUPPLIED BY FIXT. VENDOR1 MPOS Manager Point of Sale6 MWU-D Merchandise Wall Unit5 MWU-GRAP
HICMerchandise unit with graphic back
2 WINB Window Banner
Room # Room Name Area Perimeter Floor Base Wall Ceiling Comments
101 Sales Floor 1492 SF 164' - 4" See Finish Plan RB-1 See Finish Plan & Interior Elevations See Ceiling Plan104 Hallway 35 SF 24' - 0" See Finish Plan RB-1 P-4E / FRP-1 See Ceiling Plan
3" = 1'-0"S9 Detail @ Typical Door Jamb 3" = 1'-0"S12 Detail @ Typical Door Head
1 1/2" = 1'-0"L14 Transition @ VCT & Carpet
# Description Date
FOR DESIGN INTENT
REFERENCE ONLY
SHEET NOTES
KEY NOTES
LEGEND & ABBREVIATIONSFRAME TYPESDOOR TYPESDOOR SCHEDULE
FINISH SCHEDULE
FINISH LEGENDFIXTURE SCHEDULE
1/2" = 1'-0"D9 RUBBER BASE PLAN @ FIXTURES
FOR DESIG
N INTENT O
NLY
PROJECT LIMIT LINE
PROJ
ECT
LIMIT
LINE
S11A3.1
S1A3.1
2' - 0" 2' - 0"
EQEQ
4' - 6
"
3' - 0"
3' - 0
"
2' - 0
"2'
- 0"
3' - 0" 3' - 0"
F4A
F4A
F4A
F4A
F4A
F4A
F4AF4A
F4A F4A
F4A
F4A
F12 F12 F12
ACP-111' - 0"A.F.F.
F4A
F4A
F4A
F4AF4AF4AF4AF4AF4AF4AF4AF4A
S1A3.1
2' - 0
"2'
- 0"
F16F16F16EMF16
F16
F16EM F16 F16 F16 F16
EM
F4A
F4A
25' - 6" 25' - 6"
15' -
9 3/4"
13' -
2 1/2"
1492 SF
Sales Floor101
50 SF
Restroom103
35 SF
Hallway104
705 SF
Work/Break Area102
64
Exit
Exit
5959595959
59
595959595959
58
58
5050500707
55
61
61
32
62
4"1' - 2"
1' - 2
"4"
32
01
Recessed Can Light Fixture
Recessed Can Wall Washer (arrow indicates direction)
Recessed Troffer Light Fixture (2x2, 2x4, etc.)
Emergency Exit Light (filled region indicates graphics face)
Sprinkler (filled dot within a circle): VikingVK462. Color: In white ceilings, White (Part #13504MC/SW1004). In grey ceilings, Brushed Chrome (Part # 13504FC/B)
Return Diffuser: Titus PAR 24"x24" Square steel air diffuser. Color: In white ceilings paint to match P-1E. In grey ceilings paint to match P-2E
Supply Diffuser: Titus OMNI 24"x24" Square steel air diffuser. Color: In white ceilings paint to match P-1E. In grey ceilings paint to match P-2E
6" 6" 1' - 2" 4"
ACP CEILING SYSTEMBANNER RAILS BY FIXTURE SUPPLIER
LIGHT FIXTURE SEE RCP
EXISTING EXTERIOR WALL
EXISTING STOREFRONT
F12 LIGHT FIXTURE
INDEPENDANT LIGHT FIXTURE SUPPORT WIRE PER CODE
INDEPENDANT SUPPORT CLIP W/ THREADED STUD & NUT ATTACHMENT ERICO PART NO. IDS OR EQUIVALENT. MIN 4 PER FIXTURE
NOTE: CONTRACTOR TO INSTALL LIGHT FIXTURE FOLLOWING MANUFACTURER’S INSTALLATION INSTRUCTIONS. MANUFACTURER-PROVIDED SPACERS TO BE USED ON ANY CEILING PANELS WHERE THE FACE OF THE CEILING PANEL IS BELOW THE GRID (SLB EDGE). SPACERS NOT TO BE USED ON ANY CEILING TILE THAT IS FLUSH (OR ABOVE) THE CEILING GRID.
168421 3 65 7 12109 11 1413 15
8421 3 65 7 12109 11 1413 15 16
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
Checked by
These drawings/specifications are the property of Oculus Inc. They are furnished as contract documents only. The seal(s) and
signature(s) apply only to the document to which they are affixed, and expressly disclaim any responsibility for all other plans,
specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the
architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any type of warranty or certification relating to the performance of products and materials
beyond those provided by their respective manufacturer. © 2016 Oculus Inc.
of
Drawn by
Issue Date
Project #
Scale
Client Approval
Temp
late
V1.0
Las
t Upd
ated
01/
09/1
4
ONE
SOUT
H ME
MORI
AL D
RIVE
| SUI
TE 15
00 | S
T.LO
UIS,
MO
6310
2(3
14) 3
67-6
100
As indicated
1/4/20
17 12
:41:50
PM
MMP
MMP
01/04/2017
17516-OH23
A3.1
Reflected CeilingPlan
Preliminary - Not ForConstruction
Piqu
a, OH
1260
Ash
Stre
et,Pi
qua,
OH 45
356
Piqu
a, OH
DES1
(Whi
tesp
ace)
1/4" = 1'-0"L5 Reflected Ceiling Plan
NOT TO SCALEMEP/HVAC Drawings shall Govern
QTY Mark Manufacturer Model Lamp Description
2 Exit Lithonia #EDG 1 120 ELN Edge-lit exit sign with battery backup27 F4A AMERLUX HORNET-HP-21-LED-E-ST-C-120-FL-2700 - Silver Finish FURNISHED WITH FIXTURE Canopy mounted LED monopoint accent light, die-cast housing, electronic constant current LED driver, canopy mount, silver texture, 28" flood, 2700K, 85 CRI, 1058 lumens3 F12 Lite Energy/ Lightolier LE/CS-44120-4XF25T8-120 (4) GE F25T8/SPX35/ECO 48" diameter large scale surface mounted luminaire with white acrylic diffuser, 20 guage dieformed steel housing, electronic ballast(s), polyester powder coat matte white finish7 F16 Cooper Lighting Metalux GC332-UNV-EB81-U-1X4-MILK WHITE LENS FGW080 (3) GE F32W/T8/SPX35 1' X 4' recessed fluorescent direct light, high reflectance white powder coat paint finish, textured front glaze acrylic lens, standard flange design works with most lay in ceilings3 F16
EMCooper Lighting Metalux GC332-120-FBP24H-EB81-U-1X4-MILK WHITE LENS
FGW080(3) GE F32W/T8/SPX35 1' X 4' recessed fluorescent direct light, high reflectance white powder coat paint finish, textured front glaze acrylic lens, standard flange design works with most lay in ceilings, back-up battery pack
NOTE: THESE DOCUMENTS CONTAIN INFORMATION PERTAINING TO THE ARCHITECTURAL SCOPE OF WORK ONLY. FOR THIS PROJECT ENGINEERING DESIGN, DOCUMENT AND SPECIFICATION PREPARATION, AS REQUIRED FOR ALL OTHER DISCIPLINES, HAVE BEEN PREPARED BY OTHERS AND ARE NOT THE RESPONSIBILITY OF THE ARCHITECT/OCULUS INC. INFORMATION INDICATED ON THESE DRAWINGS/DOCUMENTS SHOWING OR REFERENCING MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION INFORMATION WHERE IT OCCURS HAS BEEN PROVIDED AS REFERENCE INFORMATION AND IS FOR DESIGN COORDINATION PURPOSES ONLY. THE ENGINEERING DESIGNERS, AS LICENSED AND QUALIFIED PROFESSIONALS, UNDER CONTRACT TO OTHERS, SHALL REMAIN SOLELY RESPONSIBLE FOR ALL DESIGN AND APPLICABLE CODE COMPLIANCE MATTERS RELATIVE TO THEIR RESPECTIVE DISCIPLINES. THIS SHALL INCLUDE ADDRESSING AND RESOLVING ANY PLAN REVIEW COMMENTS RELATIVE TO THEIR SPECIFIC SCOPE OF WORK. THE PROJECT ENGINEERING DESIGNERS SHALL ENDEAVOR TO BRING TO THE ATTENTION OF THE ARCHITECT/OCULUS INC. ANY DESIGN CHANGE OR CODE COMPLIANCE ITEMS IMPACTING THE ARCHITECTURAL SCOPE OF WORK AS EXPEDITIOUSLY AS POSSIBLE.
1 1/2" = 1'-0"S11 Detail @ Promotional Poster 1 1/2" = 1'-0"S1 Section @ F12 Light Fixture
Key # Keynote Text01 All issues regarding the BOH facilities, including ADA, building codes,
materials, finishes, construction and engineering are the responsibility of thedealer and are outside the scope of work of these drawings.
07 Centerlines are used to layout store, including ceiling, Power/Data, Fixtures,etc. and must be marked and varified prior to start of construction. Contactarchitect immediately if there are dimensional discrepancies.
32 Promotional poster rails provided by Fixture Vendor, promotional posterprovided by others.
50 Surface mounted light fixture55 GC to set ceiling grid off centerlines as shown.58 GC to aim center light fixture toward the center display track on AATV wall
shelf.59 Light to be centered on fixture below. GC to aim light on center shelf of
MWU (if applicable).61 Light to be centered in ceiling tile as indicated on plan. GC to aim light to
shine on the center of the Community Table counter surface. Not switched.62 Light fixture to be connected to exterior signage circuit, or to be hot at all
times. Ref Electrical if applicable.64 Preferred location for main lighting switch bank. All interior lights to terminate
here. Dealer to verify & coordinate final location.
• Light fixtures are to be centered on ceiling Panels UON.• All Sales Floor light fixtures are to be ordered through Grainger per national
agreement.• Mechanical diffusers are to meet AT&T design requirements. Reference the
legend below for all new mechanical diffusers & return air grilles specification.• Not all light fixtures may be used on this project. GC to verify light quantities and
fixtures with quantities listed on drawings• Provide 100 lumen battery backups in emergency fixtures where indicated on
drawings.• Quantity of emergency fixtures (F16-EM) are to be determined by a qualified
engineer. Quantity shown may vary.• GC to coordinate all new BOH lighting with tenant prior to bid completion, and is
not included within this scope of work.
# Description Date
FOR DESIGN INTENT
REFERENCE ONLY
SHEET NOTES
KEY NOTES
LIGHTING & CEILING LEGENDLIGHT FIXTURE SCHEDULE
FOR DESIG
N INTENT O
NLY
Finish Floor0"
Sales Floor Ceiling11' - 0"
Paint Line8' - 0"
MWU-GRAPHIC MWU-GRAPHIC MWU-GRAPHIC MWU-GRAPHIC MWU-GRAPHIC
WINB
RB-1 RB-1 RB-1 RB-1
P-4E P-4E
P-1EP-1E
Finish Floor0"
Sales Floor Ceiling11' - 0"
WINB
RB-1RB-1
12P-1E P-1E
Finish Floor0"
Sales Floor Ceiling11' - 0"
Paint Line8' - 0"
IP-DMWU-D MWU-D ACC-12' MWU-D MWU-D MWU-D
RB-1 RB-1
45
Finish Floor0"
Sales Floor Ceiling11' - 0"
Paint Line8' - 0"
AATV-IL4 MWU-DOPEN
RB-1 RB-1
P-4E P-4E
P-1E
45
168421 3 65 7 12109 11 1413 15
8421 3 65 7 12109 11 1413 15 16
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
Checked by
These drawings/specifications are the property of Oculus Inc. They are furnished as contract documents only. The seal(s) and
signature(s) apply only to the document to which they are affixed, and expressly disclaim any responsibility for all other plans,
specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the
architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any type of warranty or certification relating to the performance of products and materials
beyond those provided by their respective manufacturer. © 2016 Oculus Inc.
of
Drawn by
Issue Date
Project #
Scale
Client Approval
Temp
late
V1.0
Las
t Upd
ated
01/
09/1
4
ONE
SOUT
H ME
MORI
AL D
RIVE
| SUI
TE 15
00 | S
T.LO
UIS,
MO
6310
2(3
14) 3
67-6
100
1/4" = 1'-0"
1/4/20
17 12
:41:51
PM
MMP
MMP
01/04/2017
17516-OH23
A6.1
Interior Elevations
Preliminary - Not ForConstruction
Piqu
a, OH
1260
Ash
Stre
et,Pi
qua,
OH 45
356
Piqu
a, OH
DES1
(Whi
tesp
ace)
• Provide fire retardant treated backing/blocking in wall as required. GC to coordinate backing/blocking for all Fixture Vendor-provided items.
• For additional fixture information, see A2.1• Refer to Finish Legend on A2.1 for finish designations.• GC to verify existing storefront heights as applicable.
Key # Keynote Text1245 GC to install rubber base (RB-1) @ bottom of fixture after being installed by
vendor. The front and sides of the backwrap fixture (BCW) shall receiveRB-1, and the front and sides of the AATV wall fixture (AATV) shall receiveRB-1.
# Description Date
FOR DESIGN INTENT
REFERENCE ONLY
SHEET NOTES
KEY NOTES
1/4" = 1'-0"C1 Sales Floor Elevation- East
1/4" = 1'-0"F1 Sales Floor Elevation- South
1/4" = 1'-0"J1 Sales Floor Elevation- West
1/4" = 1'-0"F7 Sales Floor Elevation- North
FOR DESIG
N INTENT O
NLY
(4D)
2D20
"C20
"2D
20"
C20"
18"
18"18" 2D18" 18" 18"
2D 2D 2D
18"
(2D)
CONV
CONV
2D 2D2D 18"
(6D)
(2D)
J40"
40"
Ded.
40"
40"
Ded.
40"
C40"
40"
40"
40"
T
PROJECT LIMIT LINE
PROJ
ECT
LIMIT
LINE
9 7/8" 2' - 8 5/8" 8' - 0 3/8" 6' - 0" 7' - 11" 11' - 3" 6' - 0" 6' - 0" 2' - 2 7/8"
14' -
0"2'
- 0"
2' - 0
"7'
- 9 7/
8"2'
- 3 3/
8"1'
- 1 1/
4"
6' - 8"
7' - 9
"
R1.15
3' - 7"CL
92
89
93 93 93 93 93 93 93
92
96 96 96
6' - 0" 6' - 0"
R1.1S4
0707
6"
6"
104
104
32
32
7' - 1 1/4" 6' - 8 1/2"
7' - 6
"4'
- 0"
TYP10"
96
96
96
92
92
92
15' - 8 7/8" 5' - 6" 4' - 3" 2' - 10" 6' - 0" 7' - 7" 9' - 0 7/8"
107 107 107 107 107
105
109
1492 SF
Sales Floor101
50 SF
Restroom103
35 SF
Hallway104
705 SF
Work/Break Area102
01
64
100
Data OutletDuplex Outlet
Quad Outlet
Quad OutletDedicated
Voice Outlet
Voice/Data Outlet
Duplex OutletDedicated
A "+" Indicates that the associated fixture is to be installed so that the bottom of the cover plate is 1" above the countertop backsplash.
Floor Duplex Outlet
Floor Data Outlet
Coaxial Cable Outlet
Junction Box
Thermostat
1' - 3
"
GC TO TINSTALL 2" LONG SHELF NEAR TOP OF PLYWOOD BACKBOARD FOR AT&T WI-FI AND MUSIC EQUIPMENT; 1 DATA JACK TO TERMINAT AT MUSIC EQUIPMENT
NEW QUAD ELECTRICAL OUTLET, WITH DEDICATED 20 AMP CIRCUIT JUST BELOW OR NEXT TO TELCO BOARD
4'x4'x3/4" PLYWOOD TELCO BACKBOARD, LOCATED AT TELCO DEMARCATION POINT WITH SPACE
ALL CABLING TO TERMINATE WITH THE 48 PORT PATCH PANEL, TO BE LOCATED WITH TELCO BOARD
TELEPHONE SERVICE ENTRACE CONDUIT AND CABLES ROUTE FROM ABOVE OR BELOW AS REQUIRED BY THE PARTICULAR INSTALLATION
1 4
3
5
2
1
2
3
4
5
2" CONDUIT TO TERMINATE NEAR DATA RACK6
LL TO SUPPLY 2" CONDUIT AND WEATHERHEAD AT ROOF WITH PULL STRING
7
6
7
3/4" CONDUIT FOR POWER
1" CONDUIT FOR DATA
FLOOR TRENCHNOTE: RECEPTACLES @ ACC ANDLEARNING TABLE TO BE ON A SINGLE 20AMP DEDICATED CIRCUIT. DO NOT ADDOTHER RECEPTACLES TO CIRC.
WIREMOLD BRAND 881RC4ATCBK
NOTE: WIREMOLD RFB4E FLOOR BOX W/2HUB ACCESSORY CAN BE USED INPLACE OF THE 881RC4ATCBK IF BOX ISAVAILABLE. IF USED, CONDUIT WOULDTERMINATE AT BOX, AND NOT STUB-UPTHROUGH FLOOR.ACC
(2D)
18"
REF.
DRA
WIN
GS
REF. DRAWINGS REF. DRAWINGS
(2D) (2D)
BeldenAX102652
BeldenAX102652
2"3"
1"
1"
2"
CHASE ALL LOWVOLTAGE STRANDSTHRU LEFT HAND CUTOUT
CHASE ALL PLUGSTRIP POWER CORDSTHRU RIGHT HAND CUTOUT 2"
CSS PRINTER
FINISH FLOORING
POWER/DATA FORTABLE TOP DEVICES
168421 3 65 7 12109 11 1413 15
8421 3 65 7 12109 11 1413 15 16
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
a
b
c
d
e
f
g
h
j
k
l
m
n
p
r
s
Checked by
These drawings/specifications are the property of Oculus Inc. They are furnished as contract documents only. The seal(s) and
signature(s) apply only to the document to which they are affixed, and expressly disclaim any responsibility for all other plans,
specifications, estimates, reports or other documents or instruments relating to or intended to be used for any part or parts of the
architectural or engineering project. Additionally these drawings and seal(s) shall in no way convey or imply any type of warranty or certification relating to the performance of products and materials
beyond those provided by their respective manufacturer. © 2016 Oculus Inc.
of
Drawn by
Issue Date
Project #
Scale
Client Approval
Temp
late
V1.0
Las
t Upd
ated
01/
09/1
4
ONE
SOUT
H ME
MORI
AL D
RIVE
| SUI
TE 15
00 | S
T.LO
UIS,
MO
6310
2(3
14) 3
67-6
100
As indicated
1/4/20
17 12
:41:52
PM
MMP
MMP
01/04/2017
17516-OH23
R1.1
Reference Plans
Preliminary - Not ForConstruction
Piqu
a, OH
1260
Ash
Stre
et,Pi
qua,
OH 45
356
Piqu
a, OH
DES1
(Whi
tesp
ace)
FOR DESIGN INTENT
REFERENCE ONLY
1/4" = 1'-0"J1 Power/Communications Reference Plan
NOTE: THESE DOCUMENTS CONTAIN INFORMATION PERTAINING TO THE ARCHITECTURAL SCOPE OF WORK ONLY. FOR THIS PROJECT ENGINEERING DESIGN, DOCUMENT AND SPECIFICATION PREPARATION, AS REQUIRED FOR ALL OTHER DISCIPLINES, HAVE BEEN PREPARED BY OTHERS AND ARE NOT THE RESPONSIBILITY OF THE ARCHITECT/OCULUS INC. INFORMATION INDICATED ON THESE DRAWINGS/DOCUMENTS SHOWING OR REFERENCING MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION INFORMATION WHERE IT OCCURS HAS BEEN PROVIDED AS REFERENCE INFORMATION AND IS FOR DESIGN COORDINATION PURPOSES ONLY. THE ENGINEERING DESIGNERS, AS LICENSED AND QUALIFIED PROFESSIONALS, UNDER CONTRACT TO OTHERS, SHALL REMAIN SOLELY RESPONSIBLE FOR ALL DESIGN AND APPLICABLE CODE COMPLIANCE MATTERS RELATIVE TO THEIR RESPECTIVE DISCIPLINES. THIS SHALL INCLUDE ADDRESSING AND RESOLVING ANY PLAN REVIEW COMMENTS RELATIVE TO THEIR SPECIFIC SCOPE OF WORK. THE PROJECT ENGINEERING DESIGNERS SHALL ENDEAVOR TO BRING TO THE ATTENTION OF THE ARCHITECT/OCULUS INC. ANY DESIGN CHANGE OR CODE COMPLIANCE ITEMS IMPACTING THE ARCHITECTURAL SCOPE OF WORK AS EXPEDITIOUSLY AS POSSIBLE.
MEP/HVAC Drawings shall Govern
• GC to provide all wiring in full compliance with the most current AT&T IT Standards, RFP V2.5 or later.
• Electrical and data information shown for reference only. Reference Electrical drawings (if applicable) for engineering design information.
• Provide pull strings in all voice/data outlet conduit.• Grommit locations to be coordinated through GC with Owner.• Sawcut and remove exist. slab shown for new MEP work. Coordinate locations
on fixture and MEP drawings. Patch and repair flooring as noted. GC to coordinate with Landlord's on-site representative prior to cutting or drilling existing slab.
• If Electrical Contractor not providing data/voice cabling, then install pull-string within each conduit for later installation by Cabling Vendor.
• All unused existing electrical outlets and/or junction boxes to be removed back to source. Patch wall as required to meet level 5 finish on Sales Floor.
• GC to coordinate with tenant for all new BOH receptacles prior to bid completion, not included in this scope of work
• Dealer to have available duplex electrical outlet in BOH area for Wi-Fi equipment - coordinate location with Wi-Fi vendor.
• Dealer to mark location of jack on ceiling to help Wi-Fi technician locate. Dealer to provide ladder for Wi-Fi technician's use.
• NO SUBSTITUTIONS ALLOWED FOR FLOOR BOXES.
3/4" = 1'-0"S9 Telco Backboard
Key # Keynote Text01 All issues regarding the BOH facilities, including ADA, building codes,
materials, finishes, construction and engineering are the responsibility of thedealer and are outside the scope of work of these drawings.
07 Centerlines are used to layout store, including ceiling, Power/Data, Fixtures,etc. and must be marked and varified prior to start of construction. Contactarchitect immediately if there are dimensional discrepancies.
32 Promotional poster rails provided by Fixture Vendor, promotional posterprovided by others.
64 Preferred location for main lighting switch bank. All interior lights to terminatehere. Dealer to verify & coordinate final location.
89 Conduit stub-up. (2) Fourplexes with insulated ground. All jacks to be insingle faceplate; use cat5e level 6 cable. Provide (1)1” conduit or (2)3/4”conduits for data and telecommunications. Provide (1)3/4” conduit for power.
92 Floor saw cutting, concrete removal, installation of dowels & wire meshreinforcing, repouring 4" concrete slab shall be by the G.C. Trenching,installation of conduits, backfilling & compaction of backfill by E.C. 4"concrete slab shall by dowelled into existing slab with #5 dowels, 6" intoexisting slab and extend 1'-0" into new slab pour. The new slab wire meshreinforcement to 1'-0" section or dowel sticking out of exisitng slab.Reference Sheet R1.1 for floor box/stub-up locations.
93 Provide dual branch circuit fourplex receptacle; 2 outlets switched (controlfixture lighting), 2 outlets hot - Provide black adhesive label with 1/4" letteringindicating "SWITCHED FOR LTG." Adhered to the half of the fourplexproviding power to switched lighting.
96 Provide Wiremold brand 881RC4ATCBK floor box, locate as indicated onplan. SUBSTITUTIONS NOT ALLOWED.
100 GC to coordinate location of Telco Equipment shelf with Tenant prior toconstruction.
104 Provide one outlet centered on display element (window banner). Mount toceiling above display element or to adjacent wall above storefront windowsas needed (see reference plans). Add additional outlets as required percode.
105 Data port in ceiling, including the RJ45 end connector, by GC forShoppertrak. Center over entry door.
107 Location of floor box for graphic backed MWU at window - must locate inorder to accomodate power at freestanding MWU fixture. Provide dualbranch circuit fouplex; 2 outlets switched (control fixture ligthing), 2 outletshot. -Provide black adhesive label with 1/4" lettering indicating "SWITCHEDFOR LTG.: Adhered to the half of the fourplex providing power to theswitched lighting. Provide Wiremold brand 881RC4ATCBK floor box, locateas indicated on plan. SUBSTITUTIONS NOT ALLOWED.
109 Data port in ceiling, including the RJ45 end connector, for WIFI access point.Dealer to have available duplex electrical outlet in “back of house” area forWi-FI equipment; Dealer to mark location of jack on ceiling to help Wi-Fitechnician locate; Dealer to provide ladder for Wi-Fi technician’s use.
# Description Date
1/4" = 1'-0"S4 Power/Data Enlarged Plan @ ACC - 3 Tables
1/2" = 1'-0"5 Detail @ Small Community Table w/ FSLS
SHEET NOTES
KEY NOTES
POWER & COMMUNICATIONS LEGEND
FOR DESIG
N INTENT O
NLY
Parki
ng
Adjacent Tenant
Land
scap
ing / L
oadin
g Zon
e
PROJECT LIMIT LINE
PROJ
ECT
LIMIT
LINE
SP&T1
SP&T2
SP&T3
iPhone iPad PERS POWER
SP&T4 VALU
PROT
1
DL/W
HP
ACC
Landscaping / Existing Parking16
' - 0"
13' -
2 1/2"
29' -
2 1/2"
11' -
4 1/8"
9' - 3
3/4"
1' - 0
"5'
- 0"
2' - 6
5/8"
1' - 7" 4' - 10" 1' - 0" 5' - 0" 1' - 0" 5' - 0" 1' - 0" 6' - 1" 6' - 1" 1' - 0" 5' - 0" 1' - 0" 5' - 0" 1' - 0" 5' - 0" 1' - 5"
IP-D MWU-D MWU-D ACC-12' MWU-D MWU-D MWU-D
AATV
BEN
CH
AATV
-IL4
MW
U-D
LT-S
LN-TBL
LT-SLT-S
LN-TBL
LT-SLT-S-ADA
ADA-LN-TBL
LT-S-ADA
14' - 0" 14' - 0"
14' - 11" 5' - 0" 6" 5' - 0" 2' - 1" 5' - 0" 1' - 0" 5' - 0" 2' - 7" 5' - 0" 4' - 11"25' - 6" 25' - 6"
51' - 0"
MWU-GRAPHICMWU-GRAPHICMWU-GRAPHICMWU-GRAPHICMWU-GRAPHIC
ADA-
MPO
S
MPOS
CT-OM
FSLS
1492 SF
Sales Floor101
705 SF
Work/Break Area102
50 SF
Restroom103
35 SF
Hallway104
2
3
4 4 4 4
4 4 4 4
5
WINB
WIN
B
No Existing Ceiling11'-0" Preferred
1' - 6
"
Existing Wall to RemainNew Construction Wall
Existing Door to Remain
New Construction Door
Storefront Glazing (Window)
Store Stats:
Description:
AT&T Uverse TV: (yes or no)
Sales Floor Size:
Total Usable SqFt:
29'-2 1/2" x 51'-0"Vertical Endcap
DTV Location: (yes or no)
Wall LegendFixture Quantities
General Notes
Keyed Notes + Red Flags
Revisions Log
1492 SF790 SF2282 SF
AATV BENCH 1AATV-IL4 1ADA-LN-TBL 1ADA-MPOS 1CT-OM 1IP-D 1LN-TBL 2LT-S 4LT-S-ADA 2MPOS 1MWU-D 6MWU-GRAPHIC 5WINB 2
AT&T Uverse Internet: (yes or no)In-Footprint: (yes or no)H.I.T. Location: (yes or no)
Sales Level + Grade:
Sales Area:BOH Area:
Floor Plan (NTS)
PRELIMINARY DESIGN - NOT FOR CONSTRUCTIONOne South Memorial Dr., Suite 1500St. Louis, MO 63102314-367-6100
AT&T - Dealer Test Fit
Piqua, OH
10/20/2016
17516-OH23 TF1
1260 Ash Street,Piqua, OH 45356
DES1 (Whitespace)
Version 1 R2
1 Coordinate exact location of restroomsand electrical panels with landlord
2 Need to verify ADA compliant drinkingfountain with landlord
1 No existing electrical panel location2 Proposed BOH wall / Restroom
location3 No existing ceiling, 11'-0" Preferred4 Existing columns to remian5 Apply Blackout Film on windows
Version # Rev. # Date1 - 09/09/20161 1 10/10/20161 2 10/20/2016
YESNOYESYESUNKNOWN
Digital Life: (yes or no) YES
Dealer: Custom Cellular, Inc.