88 HARRY ALTER CO. Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment TECUMSEH CONDENSING UNITS Suction Liquid Each AIR COOLED R-12 Condensing Units High Temperature Rated @ 45°F 20° 30° 40° 45° 50° 62520 AEA3414AXAXA 115 - 1 1/5 Normal 1,020 1,210 1,425 1,545 --- 3/8 SAE 3/8 SAE 30 $836.38 62530 AEA3417AXAXA 115 - 1 1/5 Normal 1,140 1,355 1,645 1,810 --- 3/8 SAE 3/8 SAE 33 $824.38 62532 AEA3425AXAXA 115 - 1 1/5 Normal 1,590 1,875 2,200 2,375 --- 3/8 SAE 3/8 SAE 36 $862.82 62551 AEA4430AXAXA 115 - 1 1/4 High 2,030 2,375 2,830 3,080 --- 3/8 SAE 3/8 SAE 37 $762.94 62553 AEA4430AXAXB 115 - 1 1/4 High 2,030 2,375 2,830 3,080 --- 3/8 SAE 1/4 SAE 43 $784.60 62555 AEA4430AXAXC 115 - 1 1/4 High 2,030 2,375 2,830 3,080 --- 3/8 SAE 1/4 SAE 46 $963.86 62583 AEA4440AXAXB 115 - 1 1/3 High 2,540 3,020 3,530 3,790 4,050 3/8 SAE 1/4 SAE 47 $858.60 62585 AEA4440AXAXC 115 - 1 1/3 High 2,540 3,020 3,530 3,790 4,050 3/8 SAE 1/4 SAE 50 $1,042.18 62582 AEA4440AXAXL 115 - 1 1/3 High 2,540 3,020 3,530 3,790 4,050 3/8 SAE 3/8 SAE 44 $836.96 62586 AEA4448AXAXC 115 - 1 1/3+ High 2,950 3,700 4,470 4,800 5,130 3/8 SAE 1/4 SAE 54 $1,123.00 62610 AJA4461AXAXB 115 - 1 1/2 High 3,800 4,525 5,300 5,675 --- 1/2 SAE 1/4 SAE 71 $1,440.36 62620 AJA4461AXAXC 115 - 1 1/2 High 3,800 4,525 5,300 5,675 --- 1/2 SAE 1/4 SAE 72 $1,447.82 62612 AJA4461AXDXC 208/230 - 1 1/2 High 3,800 4,525 5,300 5,675 --- 1/2 SAE 1/4 SAE 74 $1,449.08 62652 AJA4492AXAXC 115 - 1 3/4 High 5,800 6,950 8,200 8,800 9,500 5/8 SAE 3/8 SAE 92 $1,653.90 62653 AJA4492AXDXC 208/230 - 1 3/4 High 5,800 6,950 8,200 8,800 9,500 5/8 SAE 3/8 SAE 94 $1,637.60 62690 AJA4512AXDXC 208/230 - 1 1 High 7,400 8,900 10,780 11,780 12,780 5/8 SAE 3/8 SAE 95 $1,979.00 62730 AHA4518AXDXC 208/230 - 3 1 1/2 High 10,900 13,600 16,200 17,400 18,600 7/8 ODF 3/8 SAE 129 $2,465.46 R-12 Condensing Units Medium Temperature Rated @ 20°F -10° 10° 20° 30° 62622 AJA7441AXAXC 115 - 1 1/2 High --- 2,860 3,610 4,400 5,280 1/2 SAE 1/4 SAE 72 $1,443.54 62623 AJA7441AXDXC 208/230 - 1 1/2 High --- 2,860 3,610 4,400 5,280 1/2 SAE 1/4 SAE 72 $1,451.16 62650 AJA7465AXAXE 115 - 1 3/4 High --- 4,260 5,355 6,560 7,650 5/8 SAE 3/8 SAE 98 $1,926.56 62651 AJB7465AXDXE 208/230 - 1 3/4 High --- 4,260 5,355 6,560 7,650 5/8 SAE 3/8 SAE 99 $1,897.14 62691 AHA7480AXDXC 208/230 - 1 1 High 3,300 5,300 7,100 8,600 10,100 5/8 ODF 3/8 SAE 115 $2,358.02 62693 AHA7480AXFXC 208/230 - 3 1 3 PH 3,300 5,300 7,100 8,600 10,100 5/8 ODF 3/8 SAE 119 $2,741.40 90036 AHB7511AXDXC 208/230 - 1 1 1/2 High --- 8,300 10,400 12,800 14,750 7/8 ODF 3/8 SAE 130 $2,842.82 90037 AHA7511AXFXC 208/230 - 1 1 1/2 3 PH 6,200 8,300 10,400 12,800 15,790 7/8 ODF 3/8 SAE 128 $2,901.04 90046 AHA7514AXDXC 208/230 - 1 1 1/2 High 7,500 9,500 11,500 14,000 16,800 7/8 ODF 3/8 SAE 134 $2,859.38 R-12 Condensing Units Low Temperature Rated @ -10°F -30° -20° -10° 10° 62500 AEA1336AXAXA 115 - 1 1/5 Normal --- 320 450 590 740 3/8 SAE 3/8 SAE 28 $819.16 62531 AEA1360AXAXA 115 - 1 1/5 Normal --- 525 700 885 1,090 3/8 SAE 3/8 SAE 33 $835.64 62554 AEA2410AXAXA 115 - 1 1/4 High 625 900 1,250 1,600 2,000 3/8 SAE 1/4 SAE 48 $1,086.50 62584 AEA2415AABXC 115 - 1 1/3 High 980 1,380 1,800 2,200 2,600 3/8 SAE 1/4 SAE 51 $1,038.52 62614 AJA2425AXAXB 115 - 1 1/2 High 1,625 2,160 2,780 3,400 4,160 1/2 SAE 1/4 SAE 75 $1,459.54 62615 AJA2425AXAXC 115 - 1 1/2 High 1,625 2,160 2,780 3,400 4,160 1/2 SAE 1/4 SAE 74 $1,479.50 62616 AJA2425AXDXC 208/230 - 1 1/2 High 1,625 2,160 2,780 3,400 4,160 1/2 SAE 1/4 SAE 76 $1,423.48 62659 AJA2435AXDXC 208/230 - 1 1/2 High 2,050 3,050 4,100 5,200 6,300 5/8 ODF 3/8 ODF 121 $2,440.60 62696 AJA2445AXDXC 208/230 - 1 1 High 2,60 3,750 4,900 6,200 7,600 5/8 ODF 3/8 ODF 119 $2,393.80 90034 AJA2466AXDXC 208/230 - 1 1 1/2 High 3,600 5,200 6,900 8,800 10,950 7/8 ODF 3/8 ODF 140 $2,648.90 90035 AJA2466AXDXC 208/230 - 3 1 1/2 3 PH 3,600 5,200 6,900 8,800 10,950 7/8 ODF 3/8 SAE 133 $2,968.16 R-22 Condensing Units High Temperature Rated @ 45°F 20° 30° 40° 45° 50° --- AWG4516EXNXC 208/230 - 1 1 1/2 High 9,353 11,670 14,347 15,820 17,383 7/8 ODF 3/8 ODF 121 --- --- AWG4516EXTXC 208/230 - 3 1 1/2 3 PH 9,353 11,670 14,347 15,820 17,383 7/8 ODF 3/8 ODF 124 --- 62700 AWG4520EXNXC 208/230 - 1 1 1/2 High 11,771 14,607 17,587 19,131 20,711 7/8 ODF 3/8 ODF 122 $2,626.84 62701 AWG4520EXTXC 208/230 - 1 1 1/2 3 PH 11,771 14,607 17,587 19,131 20,711 7/8 ODF 3/8 ODF 123 $2,783.54 See next page for more R-22 High Temperature Rated Connection Size Wt (lbs) Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F) Starting Torque No. Model Number Volt / Ph HP TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com AE4440AB AK9446EC AJ7465BE Refrigeration

Upload: vuhanh

Post on 24-Mar-2018

363 views

Category:

Documents


9 download

TRANSCRIPT

Page 1: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

88 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TECUMSEH CONDENSING UNITS

Suction Liquid EachAIR COOLEDR-12 Condensing Units

High Temperature Rated @ 45°F 20° 30° 40° 45° 50°62520 AEA3414AXAXA 115 - 1 1/5 Normal 1,020 1,210 1,425 1,545 --- 3/8 SAE 3/8 SAE 30 $836.3862530 AEA3417AXAXA 115 - 1 1/5 Normal 1,140 1,355 1,645 1,810 --- 3/8 SAE 3/8 SAE 33 $824.3862532 AEA3425AXAXA 115 - 1 1/5 Normal 1,590 1,875 2,200 2,375 --- 3/8 SAE 3/8 SAE 36 $862.8262551 AEA4430AXAXA 115 - 1 1/4 High 2,030 2,375 2,830 3,080 --- 3/8 SAE 3/8 SAE 37 $762.9462553 AEA4430AXAXB 115 - 1 1/4 High 2,030 2,375 2,830 3,080 --- 3/8 SAE 1/4 SAE 43 $784.6062555 AEA4430AXAXC 115 - 1 1/4 High 2,030 2,375 2,830 3,080 --- 3/8 SAE 1/4 SAE 46 $963.8662583 AEA4440AXAXB 115 - 1 1/3 High 2,540 3,020 3,530 3,790 4,050 3/8 SAE 1/4 SAE 47 $858.6062585 AEA4440AXAXC 115 - 1 1/3 High 2,540 3,020 3,530 3,790 4,050 3/8 SAE 1/4 SAE 50 $1,042.1862582 AEA4440AXAXL 115 - 1 1/3 High 2,540 3,020 3,530 3,790 4,050 3/8 SAE 3/8 SAE 44 $836.9662586 AEA4448AXAXC 115 - 1 1/3+ High 2,950 3,700 4,470 4,800 5,130 3/8 SAE 1/4 SAE 54 $1,123.0062610 AJA4461AXAXB 115 - 1 1/2 High 3,800 4,525 5,300 5,675 --- 1/2 SAE 1/4 SAE 71 $1,440.3662620 AJA4461AXAXC 115 - 1 1/2 High 3,800 4,525 5,300 5,675 --- 1/2 SAE 1/4 SAE 72 $1,447.8262612 AJA4461AXDXC 208/230 - 1 1/2 High 3,800 4,525 5,300 5,675 --- 1/2 SAE 1/4 SAE 74 $1,449.0862652 AJA4492AXAXC 115 - 1 3/4 High 5,800 6,950 8,200 8,800 9,500 5/8 SAE 3/8 SAE 92 $1,653.9062653 AJA4492AXDXC 208/230 - 1 3/4 High 5,800 6,950 8,200 8,800 9,500 5/8 SAE 3/8 SAE 94 $1,637.6062690 AJA4512AXDXC 208/230 - 1 1 High 7,400 8,900 10,780 11,780 12,780 5/8 SAE 3/8 SAE 95 $1,979.0062730 AHA4518AXDXC 208/230 - 3 1 1/2 High 10,900 13,600 16,200 17,400 18,600 7/8 ODF 3/8 SAE 129 $2,465.46

R-12 Condensing UnitsMedium Temperature Rated @ 20°F -10° 0° 10° 20° 30°

62622 AJA7441AXAXC 115 - 1 1/2 High --- 2,860 3,610 4,400 5,280 1/2 SAE 1/4 SAE 72 $1,443.5462623 AJA7441AXDXC 208/230 - 1 1/2 High --- 2,860 3,610 4,400 5,280 1/2 SAE 1/4 SAE 72 $1,451.1662650 AJA7465AXAXE 115 - 1 3/4 High --- 4,260 5,355 6,560 7,650 5/8 SAE 3/8 SAE 98 $1,926.5662651 AJB7465AXDXE 208/230 - 1 3/4 High --- 4,260 5,355 6,560 7,650 5/8 SAE 3/8 SAE 99 $1,897.1462691 AHA7480AXDXC 208/230 - 1 1 High 3,300 5,300 7,100 8,600 10,100 5/8 ODF 3/8 SAE 115 $2,358.0262693 AHA7480AXFXC 208/230 - 3 1 3 PH 3,300 5,300 7,100 8,600 10,100 5/8 ODF 3/8 SAE 119 $2,741.4090036 AHB7511AXDXC 208/230 - 1 1 1/2 High --- 8,300 10,400 12,800 14,750 7/8 ODF 3/8 SAE 130 $2,842.8290037 AHA7511AXFXC 208/230 - 1 1 1/2 3 PH 6,200 8,300 10,400 12,800 15,790 7/8 ODF 3/8 SAE 128 $2,901.0490046 AHA7514AXDXC 208/230 - 1 1 1/2 High 7,500 9,500 11,500 14,000 16,800 7/8 ODF 3/8 SAE 134 $2,859.38

R-12 Condensing UnitsLow Temperature Rated @ -10°F -30° -20° -10° 0° 10°

62500 AEA1336AXAXA 115 - 1 1/5 Normal --- 320 450 590 740 3/8 SAE 3/8 SAE 28 $819.1662531 AEA1360AXAXA 115 - 1 1/5 Normal --- 525 700 885 1,090 3/8 SAE 3/8 SAE 33 $835.6462554 AEA2410AXAXA 115 - 1 1/4 High 625 900 1,250 1,600 2,000 3/8 SAE 1/4 SAE 48 $1,086.5062584 AEA2415AABXC 115 - 1 1/3 High 980 1,380 1,800 2,200 2,600 3/8 SAE 1/4 SAE 51 $1,038.5262614 AJA2425AXAXB 115 - 1 1/2 High 1,625 2,160 2,780 3,400 4,160 1/2 SAE 1/4 SAE 75 $1,459.5462615 AJA2425AXAXC 115 - 1 1/2 High 1,625 2,160 2,780 3,400 4,160 1/2 SAE 1/4 SAE 74 $1,479.5062616 AJA2425AXDXC 208/230 - 1 1/2 High 1,625 2,160 2,780 3,400 4,160 1/2 SAE 1/4 SAE 76 $1,423.4862659 AJA2435AXDXC 208/230 - 1 1/2 High 2,050 3,050 4,100 5,200 6,300 5/8 ODF 3/8 ODF 121 $2,440.6062696 AJA2445AXDXC 208/230 - 1 1 High 2,60 3,750 4,900 6,200 7,600 5/8 ODF 3/8 ODF 119 $2,393.8090034 AJA2466AXDXC 208/230 - 1 1 1/2 High 3,600 5,200 6,900 8,800 10,950 7/8 ODF 3/8 ODF 140 $2,648.9090035 AJA2466AXDXC 208/230 - 3 1 1/2 3 PH 3,600 5,200 6,900 8,800 10,950 7/8 ODF 3/8 SAE 133 $2,968.16

R-22 Condensing UnitsHigh Temperature Rated @ 45°F 20° 30° 40° 45° 50°

--- AWG4516EXNXC 208/230 - 1 1 1/2 High 9,353 11,670 14,347 15,820 17,383 7/8 ODF 3/8 ODF 121 ------ AWG4516EXTXC 208/230 - 3 1 1/2 3 PH 9,353 11,670 14,347 15,820 17,383 7/8 ODF 3/8 ODF 124 ---62700 AWG4520EXNXC 208/230 - 1 1 1/2 High 11,771 14,607 17,587 19,131 20,711 7/8 ODF 3/8 ODF 122 $2,626.8462701 AWG4520EXTXC 208/230 - 1 1 1/2 3 PH 11,771 14,607 17,587 19,131 20,711 7/8 ODF 3/8 ODF 123 $2,783.54See next page for more R-22 High Temperature Rated

Connection Size Wt(lbs)

Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F)

StartingTorqueNo. Model Number Volt / Ph HP

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

AE4440ABAK9446EC AJ7465BE

Ref

rig

erat

ion

Page 2: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

89HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

Suction Liquid EachAIR COOLEDR-22 Condensing Units

High Temperature Rated @ 45°F (continued) 20° 30° 40° 45° 50°62702 AWG4524EXNXM 208/230 - 1 2 High 14,683 18,207 22,102 24,189 26,368 7/8 ODF 3/8 ODF 187 $3,574.5262703 AWG4524EXTXM 208/230 - 3 2 3 PH 14,683 18,207 22,102 24,189 26,368 7/8 ODF 3/8 ODF 185 $3,876.8662704 AWG4530EXNXM 208/230 - 1 3 High 18,626 23,046 27,845 30,387 33,023 7/8 ODF 3/8 ODF 200 $3,900.7462705 AWG4530EXTXM 208/230 - 3 3 3 PH 18,626 23,046 27,845 30,387 33,023 7/8 ODF 3/8 ODF 196 $4,091.6662706 AVA4540EXNXM 208/230 - 1 3 High 24,901 30,467 36,337 39,386 42,512 7/8 ODF 3/8 ODF 223 $3,909.1862707 AVA4540EXTXM 208/230 - 3 3 3 PH 24,901 30,467 36,337 39,386 42,512 7/8 ODF 3/8 ODF 211 $4,273.08--- AGA4553EXNXM 208/230 - 1 4 High 35,000 41,500 49,200 53,000 56,000 7/8 ODF 1/2 SAE 315 ---62726 AGA4553EXTXM 208/230 - 3 4 3 PH 35,000 41,500 49,200 53,000 56,000 7/8 ODF 1/2 SAE 305 $5,228.7662727 AGA4563EXNXM 208/230 - 1 5 High 42,000 50,000 58,000 62,450 65,300 7/8 ODF 1/2 SAE 340 $5,761.6462728 AGA4563EXTXM 208/230 - 3 5 3 PH 42,000 50,000 58,000 62,450 65,300 7/8 ODF 1/2 SAE 320 $5,607.78--- AGA4572EXNXM 208/230 - 1 6 High 44,000 55,000 67,000 72,000 80,000 7/8 ODF 1/2 SAE 345 ------ AGA4572EXTXM 208/230 - 3 6 3 PH 44,000 55,000 67,000 72,000 80,000 7/8 ODF 1/2 SAE 325 ---

R-22 Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AEA0417EXAXA 115 - 1 1/5 Normal 1,100 1,410 1,760 2,130 2,530 3/8 SAE 3/8 SAE 36 ------ AEA9417EXAXB 115 - 1 1/5 High 1,000 1,280 1,630 2,000 2,400 3/8 SAE 1/4 SAE 43 ------ AEA9417EXAXC 115 - 1 1/5 High 1,000 1,280 1,630 2,000 2,400 3/8 SAE 1/4 SAE 52 ------ AEA9417EXAXG 115 - 1 1/5 High 1,060 1,360 1,670 2,000 2,380 3/8 SAE 1/4 ODF 38 ---62100 AEA9423EXAXA 115 - 1 1/4 High 1,430 1,840 2,300 2,860 3,560 3/8 SAE 3/8 SAE 44 $960.14--- AEA9423EXAXA 115 - 1 1/4 High 1,430 1,840 2,300 2,860 3,560 3/8 SAE 3/8 SAE 44 ---62101 AEA9423EXAXB 115 - 1 1/4 High 1,430 1,840 2,300 2,860 3,560 3/8 SAE 3/8 SAE 46 $152.8062102 AEA9423EXAXC 115 - 1 1/4 High 1,430 1,840 2,300 2,860 3,560 3/8 SAE 1/4 SAE 50 $1,134.82--- AEA9423EXAXE 115 - 1 1/4 High 1,430 1,840 2,300 2,860 3,560 3/8 SAE 1/4 SAE 51 ------ AEA9423EXAXG 115 - 1 1/4 High 1,430 1,840 2,300 2,860 3,560 5/16 ODF 1/4 SAE 33 ---62103 AKA9433EXAXB 115 - 1 1/3 High 1,890 2,580 3,320 4,030 5,100 1/2 SAE 1/4 SAE 64 $1,135.44--- AKA9433EXAXC 115 - 1 1/3 High 1,890 2,580 3,320 4,030 5,100 1/2 SAE 1/4 SAE 66 ---62104 AKA9433EXAXC 115 - 1 1/3 High 1,890 2,580 3,320 4,030 5,100 1/2 SAE 1/4 SAE 67 $1,194.9062126 AKA9433EXDXC 208/230 - 1 1/3 High 1,890 2,580 3,320 4,030 5,100 1/2 SAE 1/4 SAE 66 $1,370.5662125 AKA9446EXAXC 115 - 1 1/2 High 2,600 3,500 4,600 5,700 6,900 1/2 SAE 1/4 SAE 74 $1,427.60--- AKA9446EXAXE 115 - 1 1/2 High 2,600 3,500 4,600 5,700 6,900 1/2 SAE 1/4 SAE 86 ---62127 AKA9446EXDXC 208/230 - 1 1/2 High 2,600 3,500 4,600 5,700 6,900 1/2 SAE 1/4 SAE 76 $1,427.60--- AKA9446EXDXE 208/230 - 1 1/2 High 2,600 3,500 4,600 5,700 6,900 1/2 SAE 1/4 SAE 84 ---62128 AKA9461EXDXC 208/230 - 1 3/4 High 3,500 4,700 6,100 7,700 9,300 1/2 SAE 3/8 SAE 88 $1,581.84--- AKA9461EXDXD 208/230 - 1 3/4 High 3,500 4,700 6,100 7,700 9,300 1/2 SAE 1/4 SAE 82 ------ AKA9461EXDXE 208/230 - 1 3/4 High 3,500 4,700 6,100 7,700 9,300 1/2 SAE 3/8 SAE 90 ---62129 AKA9470EXDXC 208/230 - 1 1 High 4,300 5,600 7,000 8,500 10,100 1/2 SAE 3/8 SAE 84 $1,637.20--- AKA9470EXDXD 208/230 - 1 1 High 4,300 5,600 7,000 8,500 10,100 1/2 SAE 1/4 SAE 82 ------ AKA9470EXDXE 208/230 - 1 1 High 4,300 5,600 7,000 8,500 10,100 1/2 SAE 3/8 SAE 89 ---62130 AJA9486EXDXC 208/230 - 1 1 High 5,100 6,800 8,600 10,400 12,400 5/8 SAE 3/8 SAE 103 $2,287.34--- AJA9486EXDXD 208/230 - 1 1 High 5,100 6,800 8,600 10,400 12,400 1/2 ODF 1/4 ODF 97 ------ AJA9486EXDXE 208/230 - 1 1 High 5,100 6,800 8,600 10,400 12,400 5/8 SAE 3/8 SAE 106 ---

R-134A Condensing UnitsHigh Temperature Rated @ 45°F 20° 30° 40° 45° 50°

--- AEA3414YXAXA 115 - 1 1/5 Normal 860 1,010 1,190 1,280 1,380 3/8 SAE 3/8 SAE 29 ---62529 AEA3417YXAXA 115 - 1 1/5 Normal 1,100 1,350 1,660 1,820 2,000 3/8 SAE 3/8 SAE 33 $709.6462533 AEA3425YXAXA 115 - 1 1/5 Normal 1,460 1,790 2,140 2,330 2,520 3/8 SAE 3/8 SAE 37 $709.02--- AEA3430YXAXA 115 - 1 1/3 Normal 1,710 2,200 2,600 2,820 3,070 3/8 SAE 3/8 SAE 38 ---62556 AEA4430YXAXA 115 - 1 1/4 High 1,740 2,140 2,590 2,820 3,050 3/8 SAE 3/8 SAE 37 $779.6662557 AEA4430YXAXB 115 - 1 1/4 High 1,740 2,140 2,590 2,820 3,050 3/8 SAE 1/4 SAE 43 $836.6462558 AEA4430YXAXC 115 - 1 1/4 High 1,740 2,140 2,590 2,820 3,050 3/8 SAE 1/4 SAE 46 $988.5262588 AEA4440YXAXB 115 - 1 1/3 High 2,320 2,810 3,350 3,620 3,910 3/8 SAE 1/4 SAE 46 $906.1262589 AEA4440YXAXC 115 - 1 1/3 High 2,320 2,810 3,350 3,620 3,910 3/8 SAE 1/4 SAE 50 $1,068.7062587 AEA4440YXAXL 115 - 1 1/3 High 2,320 2,810 3,350 3,620 3,910 3/8 SAE 3/8 SAE 44 $858.4462040 AEA4448YXAXC 115 - 1 1/3 High 2,890 3,460 4,080 4,400 4,750 3/8 SAE 1/4 SAE 54 $1,147.4862617 AKA4460YXAXB 115 - 1 3/4 High 3,570 4,450 5,390 5,880 6,370 1/2 SAE 1/4 SAE 65 $1,304.7062613 AKA4460YXAXC 115 - 1 3/4 High 3,570 4,450 5,390 5,880 6,370 1/2 SAE 1/4 SAE 68 $1,392.60See next page for more R-134A High Temperature Rated

Volt / Ph HPStartingTorqueNo. Model Number

Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F)

Connection Size (in) Wt(lbs)

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

TECUMSEH CONDENSING UNITS

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 3: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

90 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TECUMSEH CONDENSING UNITS

Suction Liquid EachAIR COOLEDR-134A Condensing Units

High Temperature Rated @ 45°F (continued) 20° 30° 40° 45° 50°62618 AKA4460YXDXC 208/230 - 1 3/4 High 3,570 4,450 5,390 5,880 6,370 1/2 SAE 1/4 ODF 68 $1,394.7662619 AKA4476YXAXC 115 - 1 3/4 High 4,400 5,400 6,500 7,100 7,700 1/2 SAE 1/4 SAE 83 $1,622.5062621 AKA4476YXDXC 208/230 - 1 3/4 High 4,400 5,400 6,500 7,100 7,700 1/2 SAE 1/4 SAE 82 $1,682.7862654 AJA4492YXAXC 115 - 1 3/4 High 5,120 6,270 7,480 8,070 8,780 5/8 SAE 3/8 SAE 92 $1,718.2462655 AJA4492YXDXC 208/230 - 1 3/4 High 5,120 6,270 7,480 8,070 8,780 5/8 SAE 3/8 SAE 91 $1,697.9462692 AJA4512YXDXC 208/230 - 1 1 High 7,250 9,100 11,100 12,200 13,300 5/8 SAE 3/8 SAE 98 $1,994.88

R-134A Condensing Units Medium Temperature Rated @ 20°F -10° 0° 10° 20° 30°

--- AKA7437YXAXC 115 - 1 1/2 High 1,650 2,250 3,000 3,800 4,700 1/2 SAE 1/4 SAE 67 ---62656 AJA7465YXAXE 115 - 1 3/4 High 2,330 3,450 4,650 5,920 7,270 5/8 SAE 3/8 SAE 103 $1,931.4862661 AJA7465YXDXE 208/230 - 1 3/4 High 2,330 3,450 4,650 5,920 7,270 5/8 SAE 3/8 SAE 100 $1,899.28

R-134A Condensing UnitsLow Temperature Rated @ -10°F -30° -20° -10° 0° 10°

--- AEA1360YXAXA 115 - 1 1/5 Normal 285 390 505 625 750 3/8 SAE 3/8 SAE 35 ------ AEA2413YXAXC 115 - 1 1/3 High 657 965 1,315 1,707 2,140 3/8 SAE 1/4 SAE 52 ---

R-404A Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AEA9415ZXAXA 115 - 1 1/5 High 1,000 1,240 1,480 1,750 2,020 3/8 SAE 3/8 SAE 47 ------ AEA9415ZXAXB 115 - 1 1/5 High 1,000 1,240 1,480 1,750 2,020 3/8 SAE 1/4 SAE 47 ------ AEA9415ZXAXC 115 - 1 1/5 High 1,000 1,240 1,480 1,750 2,020 3/8 SAE 3/8 SAE 46 ------ AEA9422ZXAXA 115 - 1 1/4 High 1,540 1,860 2,200 2,570 2,980 3/8 SAE 3/8 SAE 44 ------ AEA9422ZXAXB 115 - 1 1/4 High 1,540 1,860 2,200 2,570 2,980 3/8 SAE 3/8 SAE 45 ------ AEA9422ZXAXC 115 - 1 1/4 High 1,540 1,860 2,200 2,570 2,980 3/8 SAE 3/8 SAE 50 ------ AKA9429ZXAXC 115 - 1 1/3 High 1,610 2,230 2,850 3,470 4,090 1/2 SAE 1/4 SAE 67 ------ AKA9440ZXDXC 208/230 - 1 1/2 High 2,375 3,200 4,050 5,000 6,050 1/2 SAE 1/4 SAE 71 ------ AKA9460ZXDXC 208/230 - 1 3/4 High 3,936 4,930 4,930 7,257 8,590 1/2 SAE 3/8 SAE 87 ------ AKA9463ZXDC 208/230 - 1 3/4 High 4,200 5,230 6,280 7,650 8,900 1/2 SAE 3/8 SAE 84 ------ VSA9510ZTBXC 200/230 - 3 1 3 PH 7,050 9,000 11,240 13,080 15,680 5/8 ODF 3/8 ODF 155 ------ AWA9511ZXNXC 208/230 - 1 1 High 6,619 8,759 11,392 14,517 18,135 7/8 ODF 3/8 ODF 122 ------ AWA9511ZXTXC 200/230 - 3 1 3 PH 6,619 8,759 11,392 14,517 18,135 7/8 ODF 3/8 ODF 122 ------ AWA9514ZXNXM 208/230 - 1 1 1/2 High 8,533 11,068 14,053 17,489 21,375 7/8 ODF 3/8 ODF 121 ------ AWA9514ZXTXM 200/230 - 3 1 1/2 3 PH 8,533 11,068 14,053 17,489 21,375 7/8 ODF 3/8 ODF 121 ------ VSA9515ZNAXM 208/230 - 1 2 High 9,650 12,500 15,900 18,600 22,600 5/8 ODF 3/8 ODF 290 ------ VSA9515ZTBXM 200/230 - 3 2 3 PH 9,650 12,500 15,900 18,600 22,600 5/8 ODF 3/8 ODF 290 ------ AWA9518ZXNXM 208/230 - 1 2 High 11,392 14,642 18,409 22,694 27,495 7/8 ODF 3/8 ODF 192 ------ AWA9518ZXTXM 200/230 - 3 2 3 PH 11,392 14,642 18,409 22,694 27,495 7/8 ODF 3/8 ODF 189 ------ VSA9518ZNAXM 208/230 - 1 2 High 14,527 17,446 20,957 25,222 30,077 5/8 ODF 3/8 ODF 295 ------ VSA9518ZTBXM 200/230 - 3 2 3 PH 14,527 17,446 20,957 25,222 30,077 5/8 ODF 3/8 ODF 295 ------ VSA9522ZTBXM 200/230 - 3 3 3 PH 15,727 19,044 22,799 26,284 30,207 5/8 ODF 3/8 ODF 305 ------ AVA9523ZXGXM 208/230 - 1 3 High 14,013 17,997 22,505 27,538 33,095 7/8 ODF 3/8 ODF 212 ------ AVA9523ZXTXM 200/230 - 3 3 3 PH 14,013 17,997 22,505 27,538 33,095 7/8 ODF 3/8 ODF 212 ------ AVA9525ZXGXM 460 - 3 3 High 15,777 19,874 24,517 29,707 35,443 7/8 ODF 3/8 ODF 150 ------ AVA9525ZXTXM 200/230 - 3 3 3 PH 15,777 19,874 24,517 29,707 35,443 7/8 ODF 3/8 ODF 212 ------ VSA9526ZTBXM 200/230 - 3 3 3 PH 18,370 23,240 28,830 33,410 39,910 7/8 ODF 1/2 ODF 220 ------ AVA9529ZXTXM 200/230 - 3 3.5 3 PH 19,274 23,892 28,918 34,442 40,435 7/8 ODF 3/8 ODF 212 ------ VSA9530ZXTXM 200/230 - 3 4 3 PH 20,924 25,275 30,155 36,217 42,810 7/8 ODF 1/2 ODF 235 ---

R-404A Condensing Units Medium Temperature Rated @ 20°F -10° 0° 10° 20° 30°

--- AJA7480ZXDXC 208/230 - 1 1 High 4,330 5,500 6,700 7,980 9,520 5/8 SAE 3/8 SAE 102 ------ AWA7512ZXDXC 208/230 - 1 1 High 5,910 7,686 9,694 11,934 14,407 7/8 ODF 3/8 ODF 130 ------ AWA7512ZXTXC 200/230 - 3 1 3 PH 5,910 7,686 9,694 11,934 14,407 7/8 ODF 3/8 ODF 124 ------ AWA7515ZXDXC 208/230 - 1 2 High 7,940 9,890 12,044 14,400 16,959 7/8 ODF 3/8 ODF 129 ------ AWA7515ZXTXC 200/230 - 3 2 3 PH 7,940 9,890 12,044 14,400 16,959 7/8 ODF 3/8 ODF 129 ------ AVA7523ZXNXC 208/230 - 1 3 High 11,958 15,360 18,971 22,792 26,823 7/8 ODF 3/8 ODF 212 ---90053 AVA7523ZXTXC 200/230 - 3 3 3 PH 11,958 15,360 18,971 22,792 26,823 7/8 ODF 3/8 ODF 196 $4,641.50

StartingTorque

Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F)

Connection Size (in)No. Model Number Volt / Ph HP

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

Wt(lbs)

Ref

rig

erat

ion

frig

erat

ion

Ref

rig

erat

ion

Page 4: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

91HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

Suction Liquid EachAIR COOLEDR-404A Condensing Units

Low Temperature Rated @ -10°F -30° -20° -10° 0° 10°62559 AEA2410ZXAXC 115 - 1 1/4 High 580 770 1,000 1,240 1,500 3/8 SAE 1/4 SAE 55 $1,067.70--- AEA2413ZXAXA 115 - 1 1/3 High 850 1,080 1,340 1,610 1,870 3/8 SAE 3/8 SAE 55 ---62581 AEA2413ZXAXC 115 - 1 1/3 High 850 1,080 1,340 1,610 1,870 3/8 SAE 1/4 SAE 48 $1,076.2662637 AJA2422ZXAXB 115 - 1 1/2 High 1,290 1,710 2,180 2,660 3,160 1/2 SAE 1/4 SAE 87 $1,502.8862639 AJA2422ZXAXC 115 - 1 1/2 High 1,290 1,710 2,180 2,660 3,160 1/2 SAE 1/4 SAE 79 $1,536.7862007 AJA2429ZXAXA 115 - 1 1/2 High 1,400 2,130 2,890 3,700 4,520 1/2 SAE 3/8 SAE 89 $1,657.0662006 AJA2429ZXAXB 115 - 1 1/2 High 1,400 2,130 2,890 3,700 4,520 1/2 SAE 3/8 SAE 94 $1,785.9262010 AWA2448ZXDXC 208/230 - 1 1 High 2,418 3,568 4,838 6,227 7,736 5/8 ODF 3/8 ODF 119 $2,195.8262014 AWA2448ZXTXC 200/230 - 3 1 3 PH 2,418 3,568 4,838 6,227 7,736 5/8 ODF 3/8 ODF 119 $2,337.84--- AJB2450ZXDXC 208/230 - 1 1 High 3,114 4,040 5,022 6,060 7,154 3/8 ODF 1/4 ODF 119 ------ AWA2457ZXDXC 208/230 - 1 1 High 3,098 4,365 5,738 7,219 8,807 7/8 ODF 3/8 ODF 120 ------ AWA2457ZXTXC 200/230 - 3 1 3 PH 3,098 4,365 5,738 7,219 8,807 7/8 ODF 3/8 ODF 120 ---90056 AWA2464ZXDXC 208/230 - 1 1 1/2 High 3,810 5,102 6,450 7,854 9,313 7/8 ODF 3/8 ODF 130 $2,640.2690057 AWA2464ZXTXC 200/230 - 3 1 1/2 3 PH 3,810 5,102 6,450 7,854 9,313 7/8 ODF 3/8 ODF 130 $3,186.8490038 AWA2479ZXDXC 208/230 - 1 2 High 4,080 5,925 7,871 9,918 12,067 7/8 ODF 3/8 ODF 119 $2,920.8090039 AWA2479ZXTXC 200/230 - 3 2 3 PH 4,080 5,925 7,871 9,918 12,067 7/8 ODF 3/8 ODF 119 $3,322.92--- AWA2490ZXDXC 208/230 - 1 2 High 4,098 5,365 8,790 11,372 14,112 5/8 ODF 3/8 ODF 119 ------ AWA2490ZXTXC 200/230 - 3 2 3 PH 4,098 5,365 8,790 11,372 14,112 5/8 ODF 3/8 ODF 119 ---90044 AVA2510ZXNXC 208/230 - 1 2 High 5,751 7,887 9,999 12,088 14,153 7/8 ODF 3/8 ODF 150 $1,582.9290045 AVA2510ZXTXC 200/230 - 3 2 3 PH 5,751 7,887 9,999 12,088 14,153 7/8 ODF 3/8 ODF 138 $3,354.3490054 AVA2512ZXNXM 208/230 - 1 3 High 6,531 9,102 11,851 14,778 17,884 7/8 ODF 3/8 ODF 220 $3,931.1290055 AVA2512ZXTXM 200/230 - 3 3 3 PH 6,531 9,102 11,851 14,778 17,884 7/8 ODF 3/8 ODF 220 $4,145.74--- AVA2515ZXGXC 460 - 3 3 3 PH 7,791 10,905 14,475 18,500 22,980 7/8 SAE 3/8 ODF 220 ------ AVA2515ZXNXC 208/230 - 1 3 High 7,791 10,905 14,475 18,500 22,980 7/8 ODF 3/8 ODF 222 ---90050 AVA2515ZXTXC 200/230 - 3 3 3 PH 7,791 10,905 14,475 18,500 22,980 7/8 ODF 3/8 ODF 204 $4,472.50

AIR COOLED – Celseon® R-12 Condensing Units

High Temperature Rated @ 45°F 20° 30° 40° 45° 50°--- AEA3414AXASS 115 - 1 1/6 Normal 1,090 1,300 1,540 1,670 1,800 3/8 ODF 1/4 ODF 42 --- --- AEA4430AXASK 115 - 1 1/4 High 1,970 2,490 3,010 3,270 3,540 5/16 ODF 1/4 ODF 42 ------ AEA4430AXASC 115 - 1 1/4 High 1,970 2,490 3,010 3,270 3,540 3/8 ODF 1/4 ODF 42 ------ AEA4440AXASC 115 - 1 1/3 High 2,450 2,970 3,500 3,780 4,070 3/8 ODF 1/4 ODF 42 ------ AEA4440AXASS 115 - 1 1/3 High 2,450 2,970 3,500 3,780 4,070 3/8 ODF 1/4 ODF 42 ---

R-12 Condensing UnitsLow Temperature Rated @ -10°F -30° -20° -10° 0° 10°

--- AEA2415AABSC 115 - 1 1/3 High 920 1,290 1,720 2,190 2,710 3/8 ODF 1/4 ODF 42 ---

R-22 Condensing Units Commercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AEA9415EXASB 115 - 1 1/4 High 1,070 1,350 1,690 2,090 2,550 5/16 ODF 1/4 ODF 42 ------ AEA9415EXASC 115 - 1 1/4 High 1,070 1,350 1,690 2,090 2,550 5/16 ODF 1/4 ODF 42 ------ AEA9415EXASK 115 - 1 1/4 High 1,070 1,350 1,690 2,090 2,550 5/16 ODF 1/4 ODF 42 ------ AEA9415EXASS 115 - 1 1/4 High 1,070 1,350 1,690 2,090 2,550 5/16 ODF 1/4 ODF 42 ------ AEA9422EXASB 115 - 1 1/3 High 1,120 1,850 2,440 2,890 3,200 5/16 ODF 1/4 ODF 42 ------ AEA9422EXASC 115 - 1 1/3 High 1,120 1,850 2,440 2,890 3,200 5/16 ODF 1/4 ODF 42 ------ AEA9422EXASK 115 - 1 1/3 High 1,120 1,850 2,440 2,890 3,200 5/16 ODF 1/4 ODF 42 ------ AEA9422EXASS 115 - 1 1/3 High 1,120 1,850 2,440 2,890 3,200 5/16 ODF 1/4 ODF 42 ---

R-134A Condensing UnitsHigh Temperature Rated @ 45°F 20° 30° 40° 45° 50°

--- AEB3414YXASB 115 - 1 1/6 Normal 880 1,080 1,320 1,460 1,610 5/16 ODF 1/4 ODF 42 ------ AEB3414YXASC 115 - 1 1/6 Normal 880 1,080 1,320 1,460 1,610 5/16 ODF 1/4 ODF 42 ------ AEB3414YXASK 115 - 1 1/6 Normal 880 1,080 1,320 1,460 1,610 5/16 ODF 1/4 ODF 42 ------ AEB3414YXASS 115 - 1 1/6 Normal 880 1,080 1,320 1,460 1,610 5/16 ODF 1/4 ODF 42 ------ AEB3417YXASB 115 - 1 1/5 Normal 1,170 1,400 1,700 1,860 2,050 5/16 ODF 1/4 ODF 42 ------ AEB3417YXASC 115 - 1 1/5 Normal 1,170 1,400 1,700 1,860 2,050 5/16 ODF 1/4 ODF 42 ---See next page for more R-134A High Temperature Rated

Wt(lbs)No. Model Number Volt / Ph HP

StartingTorque

Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F)

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

Connection Size (in)

6246062461624816248262462

62468

6247062450

6247162451

6247462454

62475

$702.68$773.42$855.56$883.98$861.72

$893.94

$868.26$774.00

$946.72$852.46

$699.48$605.20

$739.12

TECUMSEH CONDENSING UNITS

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 5: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

92 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TECUMSEH CONDENSING UNITS

Suction Liquid EachAIR COOLED – Celseon® R-134A Condensing Units

High Temperature Rated @ 45°F (continued) 20° 30° 40° 45° 50°--- AEB3417YXASK 115 - 1 1/5 Normal 1,170 1,400 1,700 1,860 2,050 5/16 ODF 1/4 ODF 42 ------ AEB3417YXASS 115 - 1 1/5 Normal 1,170 1,400 1,700 1,860 2,050 5/16 ODF 1/4 ODF 42 ------ AEB3425YXASB 115 - 1 1/5 Normal 1,460 1,840 2,250 2,460 2,680 5/16 ODF 1/4 ODF 42 ------ AEB3425YXASC 115 - 1 1/5 Normal 1,460 1,840 2,250 2,460 2,680 5/16 ODF 1/4 ODF 42 ------ AEB3425YXASK 115 - 1 1/5 Normal 1,460 1,840 2,250 2,460 2,680 5/16 ODF 1/4 ODF 42 ------ AEB3425YXASS 115 - 1 1/5 Normal 1,460 1,840 2,250 2,460 2,680 5/16 ODF 1/4 ODF 42 ------ AEA4430YXASB 115 - 1 1/4 High 1,800 2,260 2,730 2,970 3,210 5/16 ODF 1/4 ODF 42 ------ AEA4430YXASC 115 - 1 1/4 High 1,800 2,260 2,730 2,970 3,210 5/16 ODF 1/4 ODF 42 ------ AEA4430YXASK 115 - 1 1/4 High 1,800 2,260 2,730 2,970 3,210 5/16 ODF 1/4 ODF 42 ------ AEA4430YXASS 115 - 1 1/4 High 1,800 2,260 2,730 2,970 3,210 5/16 ODF 1/4 ODF 42 ------ AEA4440YXASB 115 - 1 1/3 High 2,340 2,890 3,470 3,770 4,090 5/16 ODF 1/4 ODF 42 ------ AEA4440YXASC 115 - 1 1/3 High 2,340 2,890 3,470 3,770 4,090 5/16 ODF 1/4 ODF 42 ------ AEA4440YXASK 115 - 1 1/3 High 2,340 2,890 3,470 3,770 4,090 5/16 ODF 1/4 ODF 42 ------ AEA4440YXASS 115 - 1 1/3 High 2,340 2,890 3,470 3,770 4,090 5/16 ODF 1/4 ODF 42 ------ AEA4448YXASB 115 - 1 1/3+ High 2,770 3,350 3,950 4,250 4,550 5/16 ODF 1/4 ODF 42 ------ AEA4448YXASC 115 - 1 1/3+ High 2,770 3,350 3,950 4,250 4,550 5/16 ODF 1/4 ODF 42 ------ AEA4448YXASK 115 - 1 1/3+ High 2,770 3,350 3,950 4,250 4,550 5/16 ODF 1/4 ODF 42 ------ AEA4448YXASS 115 - 1 1/3+ High 2,770 3,350 3,950 4,250 4,550 5/16 ODF 1/4 ODF 42 ---

R-134A Condensing UnitsLow Temperature Rated @ -10°F -30° -20° -10° 0° 10°

--- AEA1360YXASK 115 - 1 1/5 Normal 390 470 610 820 1,080 5/16 ODF 1/4 ODF 42 ------ AEA1360YXASS 115 - 1 1/5 Normal 390 470 610 820 1,080 5/16 ODF 1/4 ODF 42 ------ AEA2410YXASB 115 - 1 1/4 High 390 800 1,180 1,520 1,830 5/16 ODF 1/4 ODF 42 ------ AEA2410YXASC 115 - 1 1/4 High 390 800 1,180 1,520 1,830 5/16 ODF 1/4 ODF 42 ------ AEA2410YXASK 115 - 1 1/4 High 390 800 1,180 1,520 1,830 5/16 ODF 1/4 ODF 42 ------ AEA2410YXASS 115 - 1 1/4 High 390 800 1,180 1,520 1,830 5/16 ODF 1/4 ODF 42 ------ AEA2413YXASB 115 - 1 1/3 High 620 1,080 1,480 1,830 2,120 5/16 ODF 1/4 ODF 42 ------ AEA2413YXASC 115 - 1 1/3 High 620 1,080 1,480 1,830 2,120 5/16 ODF 1/4 ODF 42 ------ AEA2413YXASK 115 - 1 1/3 High 620 1,080 1,480 1,830 2,120 5/16 ODF 1/4 ODF 42 ------ AEA2413YXASS 115 - 1 1/3 High 620 1,080 1,480 1,830 2,120 5/16 ODF 1/4 ODF 42 ---

R-404A Condensing UnitsLow Temperatue Rated @ -10°F -30° -20° -10° 0° 10°

--- AEA2380ZXASB 115 - 1 1/4 High 610 810 1,030 1,280 1,570 5/16 ODF 1/4 ODF 42 ------ AEA2380ZXASC 115 - 1 1/4 High 610 810 1,030 1,280 1,570 5/16 ODF 1/4 ODF 42 ------ AEA2380ZXASK 115 - 1 1/3 High 610 810 1,030 1,280 1,570 5/16 ODF 1/4 ODF 42 ------ AEA2380ZXASS 115 - 1 1/3 High 610 810 1,030 1,280 1,570 5/16 ODF 1/4 ODF 42 ------ AEA2411ZXASB 115 - 1 1/3 High 790 1,060 1,340 1,630 1,940 5/16 ODF 1/4 ODF 42 ------ AEA2411ZXASC 115 - 1 1/3 High 790 1,060 1,340 1,630 1,940 5/16 ODF 1/4 ODF 42 ------ AEA2411ZXASK 115 - 1 1/3 High 790 1,060 1,340 1,630 1,940 5/16 ODF 1/4 ODF 42 ------ AEA2411ZXASS 115 - 1 1/3 High 790 1,060 1,340 1,630 1,940 5/16 ODF 1/4 ODF 42 ---

EVAP CONDENSATER-22 Condensing Units

Commercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°--- AEA9415EXAGK 115 - 1 1/5 High 950 1,216 1,653 1,976 2,352 5/16 ODF 1/4 ODF 40 ------ AEA9422EXAGB 115 - 1 1/3 High 1,406 1,800 2,376 2,925 3,481 5/16 ODF 1/4 ODF 40 ---62534 AEA9422EXAGK 115 - 1 1/3 High 1,406 1,800 2,376 2,925 3,481 5/16 ODF 1/4 ODF 40 $819.64

No. Model Number Volt / Ph HPStartingTorque

Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F)

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

Connection Size (in) Wt(lbs)

R-404A Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

62472 AEA9415ZXASC 115 - 1 1/4 High 1,070 1,300 1,530 1,740 1,950 5/16 ODF 1/4 ODF 42 $944.7062452 AEA9415ZXASK 116 - 1 1/4 High 1,070 1,300 1,530 1,740 1,950 5/16 ODF 1/4 ODF 41 $850.4062473 AEA9422ZXASC 115 - 1 1/3 High 1,400 1,820 2,280 2,790 3,340 3/8 ODF 1/4 ODF 42 $995.4862453 AEA9422ZXASK 116 - 1 1/3 High 1,070 1,300 1,530 1,740 1,950 3/8 ODF 1/4 ODF 41 $901.18

62455

6247662456

6247762457

6247862458

6247962459

6246562485

6248662466

6248762467

6248362463

6248462464

$1,016.48$922.62

$992.70$898.44

$982.08$887.76

$894.16$799.88

$748.96$806.62

$1,135.82$1,041.56

$866.18$771.92

$823.92$729.64

$738.52$644.26

$644.82

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 6: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

93HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

Suction Liquid EachEVAP CONDENSATER-134A Condensing Units

High Temperature Rated @ 45°F 20° 30° 40° 45° 50°

--- AEA4430YXAGB 115 - 1 1/4 High 1,716 2,080 2,475 2,682 2,898 5/16 ODF 1/4 ODF 40 ------ AEA4430YXAGC 115 - 1 1/4 High 1,716 2,080 2,475 2,682 2,898 5/16 ODF 1/4 ODF 41 ---62515 AEA4430YXAGK 115 - 1 1/4 High 1,716 2,080 2,475 2,682 2,898 5/16 ODF 1/4 ODF 40 $731.04--- AEA4430YXAGL 115 - 1 1/4 High 1,716 2,080 2,475 2,682 2,898 5/16 ODF 1/4 ODF 40 ------ AEA4430YXDGB 208/230 - 1 1/4 High 1,751 2,125 2,531 2,743 2,966 5/16 ODF 1/4 ODF 40 ------ AEA3440YXAGK 115 - 1 1/3 Normal 2,397 2,870 3,382 3,634 --- 5/16 ODF 1/4 ODF 40 ---

R-134A Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AEA4440YXAGB 115 - 1 1/3 High 2,397 2,870 3,382 3,634 --- 5/16 ODF 1/4 ODF 40 ------ AEA4440YXAGC 115 - 1 1/3 High 2,397 2,870 3,382 3,634 --- 5/16 ODF 1/4 ODF 41 ---62518 AEA4440YXAGK 115 - 1 1/3 High 2,397 2,870 3,382 3,634 --- 5/16 ODF 1/4 ODF 40 $731.04--- AEA4440YXAGL 115 - 1 1/3 High 2,397 2,870 3,382 3,634 --- 5/16 ODF 1/4 ODF 40 ------ AEA4440YXDGK 208/230 - 1 1/3 High 2,452 2,918 3,431 3,687 --- 5/16 ODF 1/4 ODF 40 ------ AKA4460YXAEE 115 - 1 1/2 High 3,570 4,450 5,390 5,880 --- 1/2 SAE 1/4 SAE 63 ------ AKA4476YXAED 115 - 1 1/2 High 4,400 5,400 6,500 7,110 7,700 1/2 SAE 3/8 SAE 70 ------ AKA9426YXAEC 115 - 1 1/3 High 1,500 2,050 2,600 --- --- 1/2 SAE 1/4 SAE 64 ---

R-134A Condensing UnitsMedium Temperature Rated @ 20°F -10° 0° 10° 20° 30°

--- AKA7437YXAEC 115 - 1 1/2 High 1,650 2,250 3,000 3,800 4,700 1/2 SAE 1/4 SAE 65 ------ AKA7437YXAED 115 - 1 1/2 High 1,650 2,250 3,000 3,800 4,700 1/2 SAE 1/4 SAE 65 ---

R-134A Condensing Units Low Temperature Rated @ -10°F -30° -20° -10° 0° 10°

--- AEA1360YXAGK 115 - 1 1/5 Normal 310 391 476 610 816 5/16 ODF 1/4 ODF 40 ------ AEA1410YXAGK 115 - 1 1/4 Normal 675 973 1,222 1,419 1,563 5/16 ODF 1/4 ODF 40 ------ AEA2410YXAGB 115 - 1 1/4 High 692 998 1,254 1,456 1,603 3/8 ODF 1/4 ODF 40 ------ AEA2410YXAGK 115 - 1 1/4 High 692 998 1,254 1,456 1,603 3/8 ODF 1/4 ODF 40 ------ AEA2410YXAGL 115 - 1 1/4 High 692 998 1,254 1,456 1,603 3/8 ODF 1/4 ODF 40 ---

R-404A Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AEA9415ZXAGB 115 - 1 1/5 High 1,024 1,239 1,481 1,750 2,045 5/16 ODF 1/4 ODF 40 ------ AEA9415ZXAGK 115 - 1 1/5 High 1,024 1,239 1,481 1,750 2,045 5/16 ODF 1/4 ODF 40 ------ AEA9422ZXAEC 115 - 1 1/4 High 1,406 1,800 2,376 2,925 3,481 5/16 ODF 1/4 ODF 41 ------ AEA9422ZXAGB 115 - 1 1/3 High 1,538 1,858 2,202 2,569 2,959 5/16 ODF 1/4 ODF 40 ------ AEA9422ZXAGK 115 - 1 1/3 High 1,538 1,858 2,202 2,569 2,959 5/16 ODF 1/4 ODF 40 ------ AKA9429ZXAEC 115 - 1 1/3 High 1,610 2,230 2,850 3,470 4,400 1/2 SAE 1/4 SAE 70 ---

R-404A Condensing Units Low Temperature Rated @ -10°F -30° -20° -10° 0° 10°

--- AEA2380ZXAGB 115 - 1 1/4 High 612 814 1,049 1,318 1,620 5/16 ODF 1/4 ODF 40 ------ AEA2380ZXAGK 115 - 1 1/4 High 612 814 1,049 1,318 1,620 5/16 ODF 1/4 ODF 40 ------ AEA2380ZXAGL 115 - 1 1/4 High 612 814 1,049 1,318 1,620 5/16 ODF 1/4 ODF 40 ------ AEA2411ZXAGB 115 - 1 1/3 High 851 1,101 1,381 1,691 2,032 5/16 ODF 1/4 ODF 40 ------ AEA2411ZXAGC 115 - 1 1/3 High 851 1,101 1,381 1,691 2,032 5/16 ODF 1/4 ODF 41 ------ AEA2411ZXAGK 115 - 1 1/3 High 851 1,101 1,381 1,691 2,032 5/16 ODF 1/4 ODF 40 ------ AEA2411ZXAGL 115 - 1 1/3 High 851 1,101 1,381 1,691 2,032 5/16 ODF 1/4 ODF 40 ------ AJA2422ZXAEC 115 - 1 1/2 High 1,290 1,710 2,180 2,660 3,160 1/2 SAE 1/4 SAE 99 ---

StartingTorque

Capacity (Btu/h) at 90°F Ambient Evaporator Temperature (°F)

Connection Size (in) Wt(lbs)No. Model Number Volt / Ph HP

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

Harry Alter Co. is your reliable source for refrigeration, repair, and replacement parts

800-373-4226

--- AEA3414YXAGK 115 - 1 1/6 Normal 870 1,100 1,342 1,467 1,614 5/16 ODF 1/4 ODF 40 ------ AEB3414YXAGC 115 - 1 1/6 Normal 870 1,100 1,342 1,467 1,614 5/16 ODF 1/4 ODF 41 ------ AEA3417YXAGK 115 - 1 1/5 Normal 1,016 1,271 1,562 1,718 1,885 5/16 ODF 1/4 ODF 40 ------ AEB3417YXAGB 115 - 1 1/5 Normal 1,016 1,271 1,562 1,718 1,885 5/16 ODF 1/4 ODF 40 ------ AEA3425YXAGK 115 - 1 1/5 Normal 1,468 1,822 2,193 2,382 2,575 5/16 ODF 1/4 ODF 40 ------ AEA3430YXAGK 115 - 1 1/4 Normal 1,716 2,080 2,475 2,682 2,898 5/16 ODF 1/4 ODF 40 ---

TECUMSEH CONDENSING UNITS

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 7: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

94 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TECUMSEH CONDENSING UNITS

Suction Liquid EachOUTDOOR CONDENSING UNITR-22 Condensing Units

High Temperature Rated @ 45°F 20° 30° 40° 45° 50°--- AWG4518EXNHG 208/230 - 1 1 1/2 High 10,292 12,938 15,753 17,224 18,737 5/8 ODF 3/8 ODF 206 ------ AWG4518EXNHG 208/230 - 1 1 1/2 High 10,292 12,938 15,753 17,224 18,737 5/8 ODF 3/8 ODF 350 ------ AWG4520EXTHG 200/230 - 3 1 1/2 3 PH 11,819 14,604 17,566 19,114 20,707 5/8 ODF 3/8 ODF 209 ------ AWG4520EXTHG 200/230 - 3 1 1/2 3 PH 11,819 14,604 17,566 19,114 20,707 5/8 ODF 3/8 ODF 350 ---62699 AWG4520EXNHL 208/230 - 1 1 1/2 High 11,789 14,626 17,582 20,658 5/8 ODF 3/8 ODF 200 $3,991.42--- AWG4520EXTHL 200/230 - 3 1 1/2 High 11,789 14,626 17,582 20,658 5/8 ODF 3/8 ODF 200 ------ AWG4523EXNHG 208/230 - 1 2 High 13,946 17,430 21,188 23,169 25,218 7/8 ODF 3/8 ODF 385 ------ AWG4523EXNHG 200/230 - 3 2 High 13,946 17,430 21,188 23,169 25,218 7/8 ODF 3/8 ODF 260 ------ AWG4523EXTHG 200/230 - 3 2 3 PH 13,946 17,430 21,188 23,169 25,218 7/8 ODF 3/8 ODF 266 ------ AWG4525EXNHG 208/230 - 1 2 High 13,946 17,430 21,188 23,169 25,218 7/8 ODF 3/8 ODF 262 ------ AWG4524EXNHN 208/230 - 3 2 High 13,900 17,400 21,200 23,200 25,200 5/8 ODF 3/8 ODF 300 ------ AWG4524EXTHN 200/230 - 3 2 3 PH 13,900 17,400 21,200 23,200 25,200 5/8 ODF 3/8 ODF 300 ------ AWG4525EXTHG 200/230 - 3 2 3 PH 14,793 18,617 22,847 25,114 27,482 7/8 ODF 3/8 ODF 385 ------ AWG4530EXNHN 208/230 - 1 2 1/2 High 17,900 22,100 26,800 29,300 31,900 5/8 ODF 3/8 ODF 300 ------ AWG4530EXTHN 200/230 - 3 2 1/2 3 PH 17,900 22,100 26,800 29,300 31,900 5/8 ODF 3/8 ODF 300 ------ AWG4530EXNHG 208/230 - 1 2 1/2 High 18,601 22,950 27,793 30,400 33,129 7/8 ODF 3/8 ODF 253 ------ AWG4530EXNHG 208/230 - 1 2 1/2 High 18,601 22,950 27,793 30,400 33,129 7/8 ODF 3/8 ODF 385 ------ AWG4530EXTHG 200/230 - 3 2 1/2 3 PH 18,601 22,950 27,793 30,400 33,129 7/8 ODF 3/8 ODF 385 ------ AWG4530EXTHG 200/230 - 3 2 1/2 3 PH 18,601 22,950 27,793 30,400 33,129 7/8 ODF 3/8 ODF 385 ------ AVA4540EXNHN 208/230 - 1 3 High 23,600 29,000 34,700 37,600 40,600 7/8 ODF 1/2 ODF 280 ------ AVA4540EXTHN 200/230 - 3 3 3 PH 23,600 29,000 34,700 37,600 40,600 7/8 ODF 1/2 ODF 280 ------ AVA4544EXNHG 208/230 - 1 3 1/2 High 26,383 32,690 39,729 43,522 47,497 7/8 ODF 3/8 ODF 287 ------ AVA4544EXTHG 200/230 - 3 3 1/2 3 PH 26,383 32,690 39,729 43,522 47,497 7/8 ODF 3/8 ODF 283 ------ AVA4547EXNHG 208/230 - 1 3 1/2 High 26,383 32,690 39,729 43,522 47,497 7/8 ODF 1/2 ODF 379 ------ AVA4547EXTHG 200/230 - 3 3 1/2 3 PH 26,383 32,690 39,729 43,522 47,497 7/8 ODF 1/2 ODF 369 ------ AGA4553EXNHM 208/230 - 1 4 High 33,600 40,400 47,400 50,900 54,500 7/8 ODF 1/2 ODF 500 ------ AGA4553EXTHM 200/230 - 3 4 3 PH 33,600 40,400 47,400 50,900 54,500 7/8 ODF 1/2 ODF 500 ------ AGA4551EXNHG 208/230 - 1 4 High 33,550 40,025 47,600 51,325 54,250 7/8 ODF 1/2 ODF 419 ------ AGA4551EXTHG 200/230 - 3 4 3 PH 33,550 40,025 47,600 51,325 54,250 7/8 ODF 1/2 ODF 463 ------ AGA4563EXNHM 208/230 - 1 5 High 39,700 48,100 56,100 60,000 63,800 7/8 ODF 1/2 ODF 500 ------ AGA4563EXTHM 200/230 - 3 5 3 PH 39,700 48,100 56,100 60,000 63,800 7/8 ODF 1/2 ODF 500 ------ AGA4560EXNHG 208/230 - 1 5 High 39,800 47,750 56,050 60,475 63,375 7/8 ODF 1/2 ODF 463 ------ AGA4560EXTHG 200/230 - 3 5 3 PH 39,800 47,750 56,050 60,475 63,375 7/8 ODF 1/2 ODF 414 ------ AGA4572EXNHM 208/230 - 1 6 High 41,700 52,500 64,300 70,600 77,200 7/8 ODF 1/2 ODF 500 ------ AGA4572EXTHM 200/230 - 3 6 3 PH 41,700 52,500 64,300 70,600 77,200 7/8 ODF 1/2 ODF 500 ------ AGA4572EXNHG 208/230 - 1 6 High 44,000 55,000 67,000 72,000 80,000 7/8 ODF 1/2 ODF 436 ------ AGA4572EXTHG 200/230 - 3 6 3 PH 44,000 55,000 67,000 72,000 80,000 7/8 ODF 1/2 ODF 463 ---

R-22 Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AKA9446EXDHG 208/230 - 1 1/2 High 2,496 3,432 4,524 5,642 6,890 3/8 ODF 1/4 ODF 325 ------ AKA9459EXDHG 208/230 - 1 3/4 High 3,400 4,550 4,900 7,450 9,000 3/8 ODF 1/4 ODF 325 ------ AKA9475EXDHG 208/230 - 1 1 High 5,424 6,943 8,650 10,543 3/8 ODF 1/4 ODF 170 ------ AJA9484EXDHG 208/230 - 1 1 High 6,307 7,981 9,842 11,890 5/8 ODF 1/4 ODF 192 ---

R-404A Condensing UnitsCommercial Temperature Rated @ 20°F 0° 10° 20° 30° 40°

--- AKA9464ZXDHG 208/230 - 1 3/4 High 3,816 4,991 6,395 8,027 9,886 5/8 ODF 1/4 ODF 325 ------ VSA9510ZTBHG 200/230 - 3 1 3 PH 6,650 8,527 10,678 12,457 14,953 7/8 ODF 1/2 ODF 400 ------ AWA9511ZXNHG 208/230 - 1 1 High 6,113 8,205 10,731 13,691 17,084 5/8 ODF 3/8 ODF 385 ------ AWA9511ZXTHG 200/230 - 3 1 3 PH 6,113 8,205 10,731 13,691 17,084 5/8 ODF 3/8 ODF 272 ------ AWA9511ZXNHL 208/230 - 1 1 1/4 High 6,585 8,529 10,750 13,248 16,021 5/8 ODF 3/8 ODF 200 ------ AWA9511ZXTHL 200/230 - 3 1 1/4 3 PH 6,585 8,529 10,750 13,248 16,021 5/8 ODF 3/8 ODF 200 ------ AWA9512ZXNHG 208/230 - 1 1 1/2 High 6,523 8,879 11,659 14,628 17,675 5/8 ODF 3/8 ODF 262 ------ AWA9514ZXNHN 208/230 - 1 1 1/2 High 7,800 10,300 13,100 16,400 20,100 5/8 ODF 3/8 ODF 300 ------ AWA9514ZXTHN 200/230 - 3 1 1/2 3 PH 7,800 10,300 13,100 16,400 20,100 5/8 ODF 3/8 ODF 300 ------ AWA9513ZXNHG 208/230 - 1 1 1/2 High 7,861 10,294 13,150 16,429 20,130 5/8 ODF 3/8 ODF 385 ------ AWA9513ZXNHG 208/230 - 1 1 1/2 High 7,861 10,294 13,150 16,429 20,130 5/8 ODF 3/8 ODF 385 ---See next page for more R-404A Commercial Temperature Rated

Volt / Ph HPStartingTorque

Capacity (Btu/h) at 95°F Ambient Evaporator Temperature (°F)No. Model Number

Connection Size Wt(lbs)

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 8: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

95HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

Suction Liquid EachOUTDOOR CONDENSING UNITR-404A Condensing Units

Commercial Temperature Rated @ 20°F (continued) 0° 10° 20° 30° 40°--- AWA9513ZXTHG 200/230 - 3 1 1/2 3 PH 7,861 10,294 13,150 16,429 20,130 5/8 ODF 3/8 ODF 247 ------ AWA9513ZXTHG 200/230 - 3 1 1/2 3 PH 7,861 10,294 13,150 16,429 20,130 5/8 ODF 3/8 ODF 385 ------ AWA9514ZXNHL 208/230 - 1 1 3/4 High 8,533 11,068 14,053 17,489 21,375 5/8 ODF 3/8 ODF 320 ------ AWA9514ZXTHL 200/230 - 3 1 3/4 3 PH 8,533 11,068 14,053 17,489 21,375 5/8 ODF 3/8 ODF 320 ------ VSA9515ZNAHG 208/230 - 1 2 High 10,086 12,258 14,990 18,307 22,150 7/8 ODF 1/2 ODF 281 ------ VSA9515ZTBHG 200/230 - 3 2 3 PH 10,086 12,258 14,990 18,307 22,150 7/8 ODF 1/2 ODF 415 ------ AWA9518ZXNHN 208/230 - 1 2 1/4 High 10,600 13,700 17,300 21,400 28,400 5/8 ODF 3/8 ODF 320 ------ AWA9518ZXTHN 200/230 - 3 2 1/4 3 PH 10,600 13,700 17,300 21,400 28,400 5/8 ODF 3/8 ODF 320 ------ VSA9518ZNAHG 208/230 - 1 2 1/2 High 14,179 17,034 20,380 24,485 29,082 7/8 ODF 1/2 ODF 281 ------ VSA9518ZTBHG 200/230 - 3 2 1/2 3 PH 14,179 17,034 20,380 24,485 29,082 7/8 ODF 1/2 ODF 415 ------ AVA9523ZXNHN 208/230 - 1 3 High 13,000 16,800 21,100 26,000 31,300 7/8 ODF 1/2 ODF 280 ------ AVA9523ZXTHN 200/230 - 3 3 3 PH 13,000 16,800 21,100 26,000 31,300 7/8 ODF 1/2 ODF 280 ------ AVA9522ZXNHG 208/230 - 1 3 High 12,641 17,769 22,397 28,605 35,418 7/8 ODF 3/8 ODF 385 ------ AVA9522ZXTHG 200/230 - 3 3 3 PH 12,641 17,769 22,397 28,605 35,418 7/8 ODF 3/8 ODF 385 ------ AVA9525ZXNHN 208/230 - 1 3 1/4 High 14,600 18,600 23,100 28,100 33,600 7/8 ODF 1/2 ODF 280 ------ AVA9525ZXTHN 200/230 - 3 3 1/4 3 PH 14,600 18,600 23,100 28,100 33,600 7/8 ODF 1/2 ODF 280 ------ VSA9522ZTBHG 200/230 - 3 3 1/4 3 PH 14,870 18,600 23,500 27,200 32,600 7/8 ODF 1/2 ODF 430 ------ AVA9529ZXNHN 208/230 - 1 3 1/2 High 18,000 22,300 27,200 32,600 38,600 7/8 ODF 1/2 ODF 280 ------ AVA9529ZXTHN 200/230 - 3 3 1/2 3 PH 18,000 22,300 27,200 32,600 38,600 7/8 ODF 1/2 ODF 280 ------ VSA9526ZTBHG 200/230 - 3 3 1/2 3 PH 17,403 22,089 27,467 31,891 38,169 7/8 ODF 1/2 ODF 470 ------ VSA9530ZXTHG 200/230 - 3 4 3 PH 20,069 24,303 29,132 34,973 41,411 7/8 ODF 1/2 ODF 480 ------ AVA9532ZXNHG 208/230 - 1 4 High 19,957 25,542 32,118 39,684 48,240 7/8 ODF 1/2 ODF 400 ------ AVA9532ZXTHG 200/230 - 3 4 3 PH 19,957 25,542 32,118 39,684 48,240 7/8 ODF 1/2 ODF 400 ------ AGA9538ZXNHM 208/230 - 1 4.5 High 21,300 27,900 35,600 44,500 54,500 7/8 ODF 1/2 ODF 500 ------ AGA9538ZXTHM 200/230 - 3 4.5 3 PH 21,300 27,900 35,600 44,500 54,500 7/8 ODF 1/2 ODF 500 ------ AGA9542ZXNHM 208/230 - 1 5 High 23,700 30,800 39,000 48,200 58,500 7/8 ODF 1/2 ODF 500 ------ AGA9542ZXTHM 200/230 - 3 5 3 PH 23,700 30,800 39,000 48,200 58,500 7/8 ODF 1/2 ODF 500 ------ AGA9539ZXNHG 208/230 - 1 5 High 23,788 30,981 39,216 48,495 58,817 7/8 ODF 1/2 ODF 400 ------ AGA9539ZXTHG 200/230 - 3 5 3 PH 23,788 30,981 39,216 48,495 58,817 7/8 ODF 1/2 ODF 400 ---

R-404A Condensing UnitsMedium Temperature Rated @ 20°F -10° 0° 10° 20° 30°

--- AWA7512ZXDHL 208/230 - 1 1 1/2 High 5,910 7,686 9,694 11,934 14,407 5/8 ODF 3/8 ODF 200 ------ AWA7512ZXTHL 200/230 - 3 1 1/2 3 PH 5,910 7,686 9,694 11,934 14,407 5/8 ODF 3/8 ODF 200 ------ AWA7515ZXDHL 208/230 - 1 1 3/4 High 7,940 9,890 12,044 14,400 16,959 5/8 ODF 3/8 ODF 200 ------ AWA7515ZXTHL 200/230 - 3 1 3/4 3 PH 7,940 9,890 12,044 14,400 16,959 5/8 ODF 3/8 ODF 200 ------ AVA7523ZXNHN 208/230 - 1 3 High 11,958 15,360 18,971 22,792 26,828 7/8 ODF 1/2 ODF 200 ------ AVA7523ZXTHN 200/230 - 3 3 3 PH 11,958 15,360 18,971 22,792 26,828 7/8 ODF 1/2 ODF 200 ---

R-404A Condensing Units Low Temperature Rated @ -10°F -30° -20° -10° 0° 10°

--- AJA2423ZXDHG 208/230 - 1 1/2 High 1,155 1,705 2,305 2,979 3,728 3/8 ODF 1/4 ODF 335 ------ AJA2423ZXDHG 208/230 - 1 1/2 High 1,155 1,705 2,305 2,979 3,728 3/8 ODF 1/4 ODF 335 ------ AJA2436ZXDHG 208/230 - 1 1/2 High 1,490 2,403 3,378 4,414 5,513 3/8 ODF 1/4 ODF 335 ------ AJA2436ZXDHG 208/230 - 1 3/4 High 1,490 2,403 3,378 4,414 5,513 3/8 ODF 1/4 ODF 335 ------ AWA2444ZXDHG 208/230 - 1 1 High 2,140 3,245 4,445 5,738 7,126 5/8 ODF 3/8 ODF 350 ------ AWA2444ZXDHG 208/230 - 1 1 High 2,140 3,245 4,445 5,738 7,126 5/8 ODF 3/8 ODF 350 ------ AWA2444ZXTHG 200/230 - 3 1 3 PH 2,140 3,245 4,445 5,738 7,126 5/8 ODF 3/8 ODF 350 ------ AWA2444ZXTHG 200/230 - 3 1 3 PH 2,140 3,245 4,445 5,738 7,126 5/8 ODF 3/8 ODF 350 ------ AWA2448ZXDHL 208/230 - 1 1 1/4 High 2,418 3,568 4,838 6,227 7,736 5/8 ODF 3/8 ODF 200 ------ AWA2448ZXTHL 200/230 - 3 1 1/4 3 PH 2,418 3,568 4,838 6,227 7,736 5/8 ODF 3/8 ODF 200 ------ AWA2457ZXDHL 208/230 - 1 1 1/2 High 3,100 4,400 5,700 7,200 8,800 5/8 ODF 3/8 ODF 200 ------ AWA2457ZXTHL 200/230 - 3 1 1/2 3 PH 3,100 4,400 5,700 7,200 8,800 5/8 ODF 3/8 ODF 200 ------ AWA2464ZXDHG 208/230 - 1 1 1/2 High 3,810 5,102 6,450 7,854 9,313 5/8 ODF 3/8 ODF 200 ------ AWA2464ZXDHG 208/230 - 1 1 1/2 High 3,810 5,102 6,450 7,854 9,313 5/8 ODF 3/8 ODF 200 ------ AWA2464ZXDHL 208/230 - 1 1 1/2 High 3,810 5,102 6,450 7,854 9,313 5/8 ODF 3/8 ODF 200 ------ AWA2464ZXTHG 200/230 - 3 1 1/2 3 PH 3,810 5,102 6,450 7,854 9,313 5/8 ODF 3/8 ODF 385 ------ AWA2464ZXTHG 200/230 - 3 1 1/2 3 PH 3,810 5,102 6,450 7,854 9,313 5/8 ODF 3/8 ODF 200 ---See next page for more R-404A Low Temperature Rated

Wt(lbs)No. Model Number Volt / Ph HP

StartingTorque

Capacity (Btu/h) at 95°F Ambient Evaporator Temperature (°F)

Connection Size

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

TECUMSEH CONDENSING UNITS

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 9: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

96 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TECUMSEH CONDENSING UNITS / PARTS

Suction Liquid EachOUTDOOR CONDENSING UNITR-404A Condensing Units

Low Temperature Rated @ -10°F (continued) -30° -20° -10° 0° 10°--- AWA2464ZXTHL 200/230 - 3 1 1/2 3 PH 3,810 5,102 6,450 7,854 9,313 5/8 ODF 3/8 ODF 200 ------ AWA2479ZXDHG 208/230 - 1 2 High 4,080 5,925 7,871 9,918 12,067 5/8 ODF 3/8 ODF 385 ------ AWA2479ZXDHG 208/230 - 1 2 High 4,080 5,925 7,871 9,918 12,067 5/8 ODF 3/8 ODF 385 ------ AWA2479ZXDHL 208/230 - 1 2 High 4,080 5,925 7,871 9,918 12,067 5/8 ODF 3/8 ODF 200 ------ AWA2479ZXTHG 200/230 - 3 2 3 PH 4,080 5,925 7,871 9,918 12,067 5/8 ODF 3/8 ODF 385 ------ AWA2479ZXTHG 200/230 - 3 2 3 PH 4,080 5,925 7,871 9,918 12,067 5/8 ODF 3/8 ODF 385 ------ AWA2479ZXTHL 200/230 - 3 2 3 PH 4,080 5,925 7,871 9,918 12,067 5/8 ODF 3/8 ODF 200 ------ AWA2481ZXDHG 208/230 - 1 2 High 3,832 5,855 8,093 10,546 13,215 5/8 ODF 3/8 ODF 385 ------ AWA2481ZXDHG 208/230 - 1 2 High 3,832 5,855 8,093 10,546 13,215 5/8 ODF 3/8 ODF 264 ------ AWA2481ZXTHG 200/230 - 3 2 3 PH 3,832 5,855 8,093 10,546 13,215 5/8 ODF 3/8 ODF 385 ------ AWA2481ZXTHG 200/230 - 3 2 3 PH 3,832 5,855 8,093 10,546 13,215 5/8 ODF 3/8 ODF 385 ------ AWA2490ZXDHN 208/230 - 1 2 High 3,900 5,900 8,100 10,500 13,200 5/8 ODF 3/8 ODF 320 ------ AWA2490ZXTHN 200/230 - 3 2 3 PH 3,900 5,900 8,100 10,500 13,200 5/8 ODF 3/8 ODF 320 ------ AVA2510ZXNHG 208/230 - 1 2 1/4 High 5,268 7,267 9,234 11,172 13,078 7/8 ODF 3/8 ODF 400 ------ AVA2510ZXNHG 208/230 - 1 2 1/4 High 5,268 7,267 9,234 11,172 13,078 7/8 ODF 3/8 ODF 400 ------ AVA2510ZXTHG 200/230 - 3 2 1/4 3 PH 5,268 7,267 9,234 11,172 13,078 7/8 ODF 3/8 ODF 400 ------ AVA2510ZXTHG 200/230 - 3 2 1/4 3 PH 5,268 7,267 9,234 11,172 13,078 7/8 ODF 3/8 ODF 400 ------ AVA2510ZXNHL 208/230 - 1 2 1/2 High 5,751 7,887 9,999 12,088 7/8 ODF 3/8 ODF 250 ------ AVA2510ZXTHL 200/230 - 3 2 1/2 3 PH 5,751 7,887 9,999 12,088 7/8 ODF 3/8 ODF 250 ------ AVA2512ZXNHN 208/230 - 1 2 3/4 High 5,900 8,300 10,900 13,700 16,700 7/8 ODF 1/2 ODF 280 ------ AVA2512ZXTHN 200/230 - 3 2 3/4 3 PH 5,900 8,300 10,900 13,700 16,700 7/8 ODF 1/2 ODF 280 ------ AVA2511ZXNHG 208/230 - 1 2 3/4 High 5,959 8,396 11,001 13,775 16,718 7/8 ODF 3/8 ODF 400 ------ AVA2511ZXNHG 208/230 - 1 2 3/4 High 5,959 8,396 11,001 13,775 16,718 7/8 ODF 3/8 ODF 400 ------ AVA2511ZXTHG 200/230 - 3 2 3/4 3 PH 5,959 8,396 11,001 13,775 16,718 7/8 ODF 3/8 ODF 400 ------ AVA2511ZXTHG 200/230 - 3 2 3/4 3 PH 5,959 8,396 11,001 13,775 16,718 7/8 ODF 3/8 ODF 270 ------ AVA2514ZXNHG 208/230 - 1 3 1/2 High 7,001 10,075 13,468 17,181 21,212 7/8 ODF 3/8 ODF 400 ------ AVA2514ZXNHG 208/230 - 1 3 1/2 High 7,001 10,075 13,468 17,181 21,212 7/8 ODF 3/8 ODF 279 ------ AVA2514ZXTHG 200/230 - 3 3 1/2 3 PH 7,001 10,075 13,468 17,181 21,212 7/8 ODF 3/8 ODF 400 ------ AVA2514ZXTHG 200/230 - 3 3 1/2 3 PH 7,001 10,075 13,468 17,181 21,212 7/8 ODF 3/8 ODF 280 ------ AVA2515ZXNHN 208/230 - 1 3 1/2 High 7,100 10,200 13,500 17,200 21,200 7/8 ODF 1/2 ODF 280 ------ AVA2515ZXTHN 200-230 - 3 3 1/2 3 PH 7,100 10,200 13,500 17,200 21,200 7/8 ODF 1/2 ODF 280 ---

Condensor Fan BladesNo. Dia. (in) Hub Bore Rotation Blades Pitch Each

18 Yes 1/2 CW 3 2318 Yes 1/2 CW 3 1914 Yes 5/16 CW 3 16

10.75 No 1/4 CW 4 3451568 14 Yes 5/16 CW 3 18

7.75 No 1/4 CW 5 3351563 12 Yes 5/16 CW 5 24

9 No 1/4 CW 5 3051566 6 No 1/4 CW 5 29

8.75 No 1/4 CW 5 2618 Yes 1/2 CW 4 23

Condensor Fan MotorsNote: All motors are CW rotation opposite shaft end

Rating Volts RPM Shft Price4 watt 115 1500 Thrd

6 watt 115 1500 Thrd

9 watt 115 1500 Thrd

9 watt 230 1500 Thrd

25 MHP 115 1500 5/16

35 MHP 230 1500 5/16

35 Watt 115 1500 Thrd

35 watt 230 1500 Thrd

1/20 HP 230 1500 5/16

1/15 HP 230 1500 5/16

1/4 HP 230 1625 1/2

Connection Size Wt(lbs)No. Model Number Volt / Ph HP

TFM1862

TFM191

TFM262

TFM351

TFM352

TFM372

TFM502

5151824A02

No.

51564-1

51567

TFM91

TFM92

TFM41

TFM61

51561-1

51533-2

51528-251529-2

51541-1

TECUMSEH Compressors those not found refer to Tecumseh full line catalog or www.tecumseh.com

StartingTorque

Capacity (Btu/h) at 95°F Ambient Evaporator Temperature (°F)

                

      

                    

$54.82$54.82$43.48$19.28$85.12$16.40$40.28$9.78$18.72$9.56$84.60

--$94.26$67.18

--$154.14$312.58$209.82$206.30$279.60$314.84$458.78

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 10: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

97HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

HWLHWL62006 AJA2429ZXAXB 21.4 13.9 12.9 62656 AJA7465YXAXE 21.4 13.9 12.962007 AJA2429ZXAXA 21.4 13.9 12.9 62659 AJA2435AXDXC 24 17 14.362010 AWA2448ZXDXC 24 17.8 15.4 62661 AJA7465YXDXE 21.4 13.9 12.962014 AWA2448ZXTXC 24 17.8 15.4 62690 AJA4512AXDXC 24.1 17.8 13.462040 AEA4448YXAXC 17.2 14 9 62691 AHA7480AXDXC 24 17.8 15.362100 AEA9423EXAXA 17.9 13 8.9 62692 AJA4512YXDXC 24.3 17.9 13.462101 AEA9423EXAXB 17.4 13 8.9 62693 AHA7480AXFXC 24 17.8 15.362102 AEA9423EXAXC 19.4 13 8.8 62696 AJA2445AXDXC 24 17.8 15.362103 AKA9433EXAXB 17.4 14 10.9 62699 AWG4520EXNHL 3'1 1/2 32.5 26.862104 AKA9433EXAXC 17.4 14 10.9 62700 AWG4520EXNXC 24 19.4 16.262125 AKA9446EXAXC 20.6 13.9 13.2 62701 AWG4520EXTXC 24 19.4 16.262126 AKA9433EXDXC 17.4 14 10.9 62702 AWG4524EXNXM 33.5 25 19.562127 AKA9446EXDXC 20.6 13.9 13.2 62703 AWG4524EXTXM 33.5 25 19.562128 AKA9461EXDXC 24.3 18 14 62704 AWG4530EXNXM 33.5 25 19.562129 AKA9470EXDXC 24.3 18 14 62705 AWG4530EXTXM 33.5 25 19.562130 AJA9486EXDXC 24 17.8 13.4 62706 AVA4540EXNXM 33.7 25 19.562500 AEA1336AXAXA 11.7 1'1 1/2 9.8 62707 AVA4540EXTXM 33.7 25 19.562515 AEA4430YXAGK 19 8.7 10.3 62726 AGA4553EXTXM 44.9 28.6 26.962518 AEA4440YXAGK 19 8.7 10.3 62727 AGA4563EXNXM 44.9 28.6 26.962520 AEA3414AXAXA 11.7 11.5 9.8 62728 AGA4563EXTXM 44.9 28.6 26.962529 AEA3417YXAXA 12.8 11.2 10.1 62730 AHA4518AXDXC 24 19.4 16.262530 AEA3417AXAXA 12.8 11.2 10.1 90034 AJA2466AXDXC 24 19.4 16.262531 AEA1360AXAXA 12.8 11.2 10.1 90035 AJA2466AXDXC 24 19.4 16.262532 AEA3425AXAXA 12.8 11.3 9.9 90036 AHB7511AXDXC 24 19.4 16.262533 AEA3425YXAXA 12.8 11.3 9.9 90037 AHA7511AXFXC 24 19.4 16.262534 AEA9422EXAGK 19 8.7 10.3 90038 AWA2479ZXDXC 24 19.4 16.262551 AEA4430AXAXA 13.4 11.7 9.9 90039 AWA2479ZXTXC 24 19.4 16.262553 AEA4430AXAXB 16.2 13 9 90044 AVA2510ZXNXC 24 19.4 16.262554 AEA2410AXAXA 18.4 13 8.9 90045 AVA2510ZXTXC 24 19.4 16.262555 AEA4430AXAXC 18.4 13 8.8 90046 AHA7514AXDXC 24 19.4 16.262556 AEA4430YXAXA 13.4 11.7 9.9 90050 AVA2515ZXTXC 25 33.5 19.562557 AEA4430YXAXB 16.2 13 8.8 90053 AVA7523ZXTXC 25 33.6 19.562558 AEA4430YXAXC 16.2 13 8.8 90054 AVA2512ZXNXM 25 33.5 19.562559 AEA2410ZXAXC 18.5 13 8.9 90055 AVA2512ZXTXM 25 33.5 19.562581 AEA2413ZXAXC 18.5 13 8.9 90056 AWA2464ZXDXC 24 17.8 15.462582 AEA4440AXAXL 17.2 13 9 90057 AWA2464ZXTXC 24 17.8 16.462583 AEA4440AXAXB 17.2 13 962584 AEA2415AABXC 19.4 13 8.8 Outdoor Condensing Unit Covers62585 AEA4440AXAXC 19.4 13 8.862586 AEA4448AXAXC 17.2 14 10.962587 AEA4440YXAXL 17.2 13 962588 AEA4440YXAXB 17.2 13 962589 AEA4440YXAXC 19.5 13 962610 AJA4461AXAXB 16.3 13.9 1262612 AJA4461AXDXC 16.4 14 11.662613 AKA4460YXAXC 17.4 14 10.962614 AJA2425AXAXB 16.3 13.9 1262615 AJA2425AXAXC 16.4 14 11.662616 AJA2425AXDXC 16.4 14 11.662617 AKA4460YXAXB 17.4 14 10.962618 AKA4460YXDXC 17.4 14 10.962619 AKA4476YXAXC 21.4 13.9 13.262620 AJA4461AXAXC 16.4 14 11.662621 AKA4476YXDXC 21.4 13.9 13.262622 AJA7441AXAXC 16.4 14 11.662623 AJA7441AXDXC 16.4 14 11.662637 AJA2422ZXAXB 16.4 14 11.662639 AJA2422ZXAXC 16.4 14 11.662650 AJA7465AXAXE 21.4 13.9 12.762651 AJB7465AXDXE 21.4 13.9 12.7 86.546$D181PT62652 AJA4492AXAXC 21.4 13.9 12.9 07.917$D102PT62653 AJA4492AXDXC 21.4 13.9 12.9 28.111,1$D142PT62654 AJA4492YXAXC 21.4 13.9 12.7 25.865,1$D113PT62655 AJA4492YXDXC 21.4 13.9 12.9 03.237,1$D104PT 33.5 x 48.5 x 45

29.5 x 37 x 27.5

No.Dimensions (in)

rebmuN ledoM.oNrebmuN ledoMDimensions (in)

33.5 x 48.5 x 35.5

26 x 20 x 16

Part No.Interior Dimensions

PriceL x W x H

27 x 24.5 x 22

       

TP-181D & 201D

TP-241D

TP-311D & 401D

TECUMSEH CONDENSING UNITS DIMENSIONS / COVERS

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 11: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

98 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TECUMSEH REPLACEMENT PARTS

sroticapaC nuRsroticapaC tratSNo. Tecumseh No. MFD Volts

48106 85PS110D20 88-108 110 lauD buSdnuoR

48111 85PS110C90 145-175 110 No. Tecumseh No. MFD Volts Substitute

48113 85PS110C91 189-227 110 --- 85PR220F12 15 220 --

--- 85PS110C76 243-292 110 --- 85PR240F37 35 240 49807

48118 85PS110C92 270-324 110 --- 85PR370E36 15 370 p2911553rs

48120 85704* 340-408 110 --- 85PR370E35 20 370 --

--- 85PR370F20 25 370 49802

No. Tecumseh No. MFD Volts --- 85PR370F23 30 370 49804

48121 85PS125D59 378-440 125 --- 85PR370F17 35 370 49807

48147 85PS165C27 270-324 165 --- 85PR370E63 40 370 49821

48191 85PS165C77 378-440 165 --- 85PR370F21 45 370 49822

48139 --- 88-108 165

48143 85PS165C96 161-193 165 No. Tecumseh No. MFD Volts Substitute

48146 85PS165C98 233-280 165 --- 85PR440F24 15 440 p2911554rs

48147 85PS165C99 270-324 165 --- 85PR440F19 20 440 --

48142 85PS165D21 145-175 165 --- 85PR440F22 25 440 p2912554rs

--- 85PR440F27 30 440 49808

No. Tecumseh No. MFD Volts --- 85PR440F18 35 440 49825

48180 --- 53-64 220 --- 85PR440F28 40 440 49811

48162 85PS220D02 72-88 220 49970 85PR440E65 45 440 49813

48163 --- 88-108 220 49971 --- 50 440 49815

48178** 85PS250D05 47-56 250 49972 85PR440E90 55 440 49817--- 85PS250D07 64-77 250 --- 85PR440F90 65 440 --

48162 85PS250C30 72-88 250

48163 85PS250D09 88-108 250 Tecumseh OEM Replacement Parts

48179 85PS250D19 124-149 250

--- 85PS250D10 130-156 250

48168 --- 161-193 250 Compressor Adapter Bases48174 85PS250A58 196-236 250 hcaE.oN48170 85PS250B87 216-259 250 K20-3

K20-5No. Tecumseh No. MFD Volts K26-2

48190 --- 216-260 320 K21-148175** 85PS330C20 25-30 330 KS35-148178** 85PS250D24 43-52 330 K35-248180** 85PS250D06 53-72 330

48183 85PS330C23 88-108 330

48182 85PS330D12 72-86 330 AK and AE air conditioning compressor bases48184 85PS330D14 108-130 330 (Not included with compressor)48185 85PS330D15 124-149 330 hcaEseloH.oN traP 48186 85PS330D16 130-156 330 41-896K48187 85PS330D17 145-175 330 33-896K

48189** 85PS330C84 189-227 330 32-896K48189** 85PS330D18 189-227 330 34-896K48188 85PS330D23 161-193 330 35-896K

** Closest replacement 26070

Extended Warranty for 2nd thru 5th yearPart No.

37074 No. Wire size Each

37075 T-110 8-12

37076 T-111 12-18

37077 T-112 12-18

37078

37080

37081 Rotolock Spud Adapter Kits

37082 No. Used on Models Each

6-03K38073 AG sweat to thread 1/2 ID 5/8 ID

8-03K48073 AG sweat to thread 1/2 ID n/a

AT to AE

AT to AE

Replacement Models

S,C,B, to AE and AJ

AN to SF

P to AE

8 x 6.125 Rt

8 x 6.125 Ctr

Mtg Clip for base

Horsepower Range Compressor Terminal Adapter Pak's

Mtg Centers

8 x 4.8

8.25 x 4.5

8 x 6.125 Lt

1/2 hp, 3/4 hp AH models

1 hp thru 1 3/4 hp AE, AK , AJ

1/8 hp, 1/6 hp, 1/5 hp Model

1/4 hp, 1/3 hp AH40

Size

7 1/2 hp thru 10 hp

12 hp and above

2 hp thru 2 3/4 hp

3 hp thru 3 3/4

4 hp thru 5 hp

5 1/2 hp

$76.32

$44.14

--

$9.48

$30.68

$24.64

$10.02

--

$20.06

$24.78

$20.06

$4.48

$6.64

$3.06

$6.06

$131.98

$38.96

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 12: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

99HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

REFRIGERATION PARTS & HEATERS

Refrigeration Parts and Heaters

No. Mfg. No. Mfg Description Wire Open Close Mount Each60321 4572 Peerless Fan Delay / Defrost Termination 3 50 25 Flange $119.0660330 4571 Peerless Heater Temperature Limit Control 2 75 40 Flange $106.8860374 5521R Bohn Defrost Control 2 ---- ---- Flange $92.3260375 5507S Bohn Fan Control Opens 2 39 29 Flange $87.4064821 13079003 Russell Heater Safety / Fan Delay 2 75 ---- Flange $131.0464822 13079002 Russell Fan Delay / Defrost Termination 3 50 25 Tube $145.3030527 F25-107 Ranco Fan Delay / Defrost Termination Adjustable Termination 45 to 75 deg (3 Wire) SPDT $145.94

No. Mfg. No. Mfg Description Each60326 4105 Peerless Thumb Screw $3.58

No. Mfg. No. Mfg Description Each60322 3246 Peerless Grill for MJ / LS / TM $12.0860402 3254 Peerless Grill for LS360 to LS540E, SF105 to SF235, PM85 and PM120, P103 and 104 $39.4260484 3275 Peerless Grill for PLP380 to PLP3000 $47.94

No. Mfg. No. Mfg Description Each60301 3550 Peerless Motor for MJ & LS50 to LS180 $107.3860302 3555 Peerless Motor for LS210 + and SF $78.3260323 3494 Peerless 230 Volt Skelton Motor $66.9660400 3543 Peerless 115 volt Motor for PLP $238.68

No. Mfg. No. Mfg Description Each60324 2997 Peerless Blade for MJ, LS50 to LS180 and TM100 to TM180 $90.1660403 3006 Peerless Blade for LS360 + and SF105 $24.0060404 3023 Peerless Blade for PLP $75.80

No. Mfg. No. Mfg Description Each60422 5101B Bohn Blade for Bohn Motor $6.36

Heatrex Tubular Straight Length Heaters

Molded moisture proof terminals with 24" pigtail leads. Made of1/4" incoloy annealed steel tubing to permit bending to fit. May bebent with a tube bender on 3/4" redius to space the tubes on 1"centers. Overall length figured without leads.

Overall No. Watts Volts Length Each61430 300 120 45" $82.1061431 450 120 68" $88.8661432 675 120 91" $95.9861434 850 120 105" $102.7061433 675 240 91" $95.9861435 850 240 105" $102.7061436 1000 240 118" $125.5261437 1250 240 188" $128.3661438 1350 240 150" $120.1461439 1500 240 216" $144.72

Door Heaters(Mullion & Dew Point)

For commercial refrigeration application to prevent moisture andeliminate frost build-up on door and cabinet fronts.

No. Model Length Watts / Ft. Volts Each60598 SH-281 36-1/2 ft 3 120 $34.0060599 SH-282 18 ft 3 120 $25.94

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 13: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

100 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

Midgette (MJ) Medium Temperature STANDARD 115/60/1 (OPTIONAL 230/1/60)

HACOP/N

60443604406044560441

MODELNO.

MJ-40MJ-70MJ-90MJ-120

BTU/HR10" TD

4007009001200

FANDIA5-1/45-1/45-1/4

5-1/4 (2)

APPROX.SHIP WT.

781015

EACH$371.20$402.30$428.04$597.42

H7777

D8899

CFM125125125250

W13-5/813-5/813-5/820-5/8

DIMENSIONSLIQ

3/8 OD3/8 OD3/8 OD3/8 OD

DRAIN1/2 OD1/2 OD1/2 OD1/2 OD

CONNECTIONS

Slope Front (SF) Medium Temperature STANDARD 115/60/1 (OPTIONAL 230/1/60)

HACOP/N

6031960460604616046260463

MODELNO.

SF-105SF-135SF-175SF-235SF-305

BTU/HR10" TD10501340175023503050

FANDIA

888810

APPROX.SHIP WT.

1416182227

EACH$575.98$598.90$610.24$720.68$975.82

H999

9-7/811

D1414141516

CFM300300300300300

W11-3/814-3/817-3/820-3/820-3/8

DIMENSIONSLIQ

1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD

DRAIN1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD

CONNECTIONS

Lo-Slope (LS) Medium Temperature STANDARD 115/60/1 (OPTIONAL 230/60/1)

HACOP/N

60451604526045360454604956045560459

MODELNO.

LS-55LS-105LS-135LS-180LS-240LS-310LS-400

BTU/HR10" TD

550105013501800240031004000

FANDIA5-1/45-1/4

2(5-1/4)2(5-1/4)

810

2(8)

APPROX.SHIP WT.

9121617233644

EACH$443.00$490.22$631.70$720.68$870.76

$1,094.84$1,405.72

H5555

6-3/88

7-1/2

D14141415

16-1/220-5/818-1/4

CFM125125225225300400600

W10

16-1/220-1/224-1/2

2430-5/8

38

DIMENSIONSLIQ

1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD

DRAIN1/2OD1/2OD1/2OD1/2OD1/2OD5/8OD5/8OD

SUCT1/2OD1/2OD1/2OD1/2OD1/2OD5/8OD5/8OD

CONNECTIONS

Lo-Slope (LS-E) Low TemperatureHACO

P/N6048560437604386048660439604876048860489

MODELNO.

LS-50E1LS-95E1LS-125E1LS-150E1LS-210E1LS210E2LS-280E1LS-280E2LS-360E2LS-54032

BTU/HR10" TD

50095012501600210021002600260036005400

FANDIA5-1/25-1/2

2(5-1/2)2(5-1/2)

871010

2(8)3(8)

APPROX.SHIP WT.

101317192424383847145

EACH$716.60$771.10$881.50

$1,046.62$1,167.10$1,524.74$1,504.36$1,760.58

H5555

6-5/86-5/8

88

7-1/27-1/2

D14141415

16-1/216-1/220-5/820-5/818-1/418-1/4

CFM125125200225300399400400600600

W10

16-1/220-1/224-1/2

2424

30-5/830-5/8

3850

DIMENSIONSLIQ

1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD1/2 OD

DRAIN1/2OD1/2OD1/2OD1/2OD1/2OD1/2OD5/8OD5/8OD5/8OD5/8OD

SUCT1/2OD1/2OD1/2OD1/2OD1/2OD1/2OD5/8OD5/8OD5/8OD5/8OD

CONNECTIONSAMPS1.803.304.315.057.523.739.804.906.108.00

WATTS2154804955808657791125112514001850

HEATERS

Twin Power Pack (TP) Medium Temperature STANDARD 115/60/1 (OPTIONAL 230/60/1)

HACOP/N

60480604816048260483

MODELNO.

TP-82DTP-83DTP-84DTP-103D

BTU/HR10" TD1500200025003000

FANDIA2(8)2(8)2(8)2(10)

APPROX.SHIP WT.

18202426

EACH$722.84$807.50$850.38$933.72

H9-1/29-1/29-1/211-1/2

D9-1/29-1/29-1/211-1/2

CFM300300400400

W16182018

DIMENSIONSLIQ

1/2 OD1/2 OD1/2 OD1/2 OD

DRAIN1/2 OD1/2 OD1/2 OD1/2 OD

SUCT3/8 OD3/8 OD3/8 OD3/8 OD

SUCT3/8 OD3/8 OD3/8 OD1/2 OD1/2 OD

SUCT3/8 OD3/8 OD3/8 OD3/8 OD

CONNECTIONS

E1 Models 115/60/1 E2 Models 230/60/1 (Order timer separately.)

EVAPORATOR COILSR

efri

ger

atio

nR

efri

ger

atio

n

Page 14: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

101HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

EVAPORATOR COILS

PP Series DPP Series TM Series PLP Series

Power Pack (P) Medium Temperature Standard 115/60/1 (230/60/1 Optional)

MODELNO.

P-82SP-83SP-103SP-104S

BTU/HR10" TD

850120013501600

FANDIA.

881010

WT

791214

EACH

$428.04$463.38$569.52$681.04

D41⁄251⁄251⁄261⁄2

CFM150150200200

W87⁄8

87⁄8

107⁄8107⁄8

H87⁄887⁄8

107⁄8107⁄8

DIMENSIONSLIQ

3⁄8 OD3⁄8 OD3⁄8 OD3⁄8 OD

DRAIN––

––

––

––

SUCT3⁄8 OD3⁄8 OD3⁄8 OD3⁄8 OD

CONNECTIONS

Two Way (TM) Medium Temperature Standard 115/60/1 (230/60/1 Optional)

MODELNO.

TM-100TM-135TM-180TM-250

BTU/HR10" TD

1000135018002500

WT

11151516

EACH

$554.52$744.30$807.50$843.98

D16161616

CFM150250250300

W203⁄8

203⁄8

203⁄8

203⁄8

H51⁄451⁄4

51⁄4

61⁄4

DIMENSIONSLIQ

3⁄8 OD3⁄8 OD3⁄8 OD3⁄8 OD

DRAIN1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD

SUCT3⁄8 OD3⁄8 OD3⁄8 OD3⁄8 OD

CONNECTIONS

Deluxe Power Pack (P) Medium Temperature Standard 115/60/1 (230/60/1 Optional)

MODELNO.

P-82DP-83DP-103DP-104D

BTU/HR10" TD

850110013501600

FANDIA.

881010

FANDIA.

51⁄42 (51⁄4)2 (51⁄4)

8

Lo-Profile (PLP) Medium Temperature Standard 115/60/1 (230/60/1 Optional)

MODELNO.

PLP-380PLP-500PLP-600PLP-750PLP-1000PLP-1500PLP-2000PLP-2500PLP-3000

BTU/HR10" TD

3800500060007500

1000015000200002500030000

WT

353846556790120155180

EACH

$775.64$600.72

$1,024.24$1,302.50$1,339.38$2,192.10$2,490.94$3,121.20$3,618.44

D121⁄4121⁄4121⁄4121⁄4121⁄4121⁄4121⁄4121⁄4121⁄4

CFM600600600120012001800240030003600

W221⁄2

27333845638199117

H131⁄2131⁄2

131⁄2

131⁄2131⁄2131⁄2131⁄2131⁄2131⁄2

DIMENSIONSLIQ

1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD

DRAIN1 FPT1 FPT1 FPT1 FPT1 FPT1 FPT1 FPT1 FPT1 FPT

SUCT5⁄8 OD5⁄8 OD7⁄8 OD7⁄8 OD7⁄8 OD7⁄8 OD11⁄8 OD11⁄8 OD11⁄8 OD

CONNECTIONSFANDIA.

101010

2 (10)2 (10)3 (10)4 (10)5 (10)6 (10)

Lo-Profile (PLP) Low Temperature Standard 230/60/1

MODELNO.

PLP-430EPLP-640EPLP-860EPLP-1290EPLP-1720EPLP-2150EPLP-2580E

WT

38556790120155180

EACH

$1,370.82$1,685.02$1,970.56$2,503.82$3,328.24$4,200.64$4,478.82

CFM600120012001800240030003600

-10°440066008800

13200176002200026400

-20°430064008600

12900172002150025800

-30°39505920790011850158001975023700

+20°50007500

1000015000200002500030000

BTU/HR 10° T.D.DIMENSIONSEVAPORATOR SUCTION TEMP. °7

LIQUID1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD

H131⁄2131⁄2131⁄2131⁄2131⁄2131⁄2131⁄2

W273845638199117

D121⁄4121⁄4121⁄4121⁄4121⁄4121⁄4121⁄4

HEATERSAMPS4.486.247.2412.3516.4118.8421.20

WATTS1030143516652840377543304875

DRAIN1 FPT1 FPT1 FPT1 FPT1 FPT1 FPT1 FPT

SUCTION5⁄8 OD7⁄8 OD7⁄8 OD7⁄8 OD

11⁄8 OD11⁄8 OD11⁄8 OD

CONNECTIONSFANDIA.10

2 (10)2 (10)3 (10)4 (10)5 (10)6 (10)

WT9101315

EACH

$484.82$512.74$625.26$698.16

D81⁄281⁄281⁄281⁄2

CFM150150200200

W10101212

H10101212

DIMENSIONSLIQ

3⁄8 OD3⁄8 OD3⁄8 OD3⁄8 OD

DRAIN1⁄2 OD1⁄2 OD1⁄2 OD1⁄2 OD

SUCT3⁄8 OD3⁄8 OD3⁄8 OD3⁄8 OD

CONNECTIONS

Ref

rig

erat

ion

HACOP/N

60442604466044760448

HACOP/N

60300604566045760458

HACOP/N

60304603056030660307

HACOP/N

604646046560466604676046860308603096031060311

HACOP/N

60312603136031560316603176031860320

Page 15: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

102 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

REFRIGERATION ACCESSORIES

Steel rotalock valves can be rotated to make theconnection in the best position. Use the Teflonseal to make a leakproof seal.

A HORIZONTAL ROTALOCK VALVEConnectionFem

No. RL Line Teflon Spud Each24450 3/4 3/8 SAE 24446 24456 $42.3224451 1 1/2 SAE 24447 24457 $61.5424452 1 5/8 SAE 24447 24457 $46.1624453 1 5/8 IDS 24447 24457 $46.1624454 1-1/4 7/8 IDS 24448 24458 $115.4024455 1-1/4 1-1/8 IDS 24448 24458 $107.70

B VERTICAL ROTALOCK VALVEConnectionFem

No. RL Line Teflon Spud Each24440 3/4 3/8 SAE 24446 24456 $50.0024441 1 1/2 SAE 24447 24457 $46.1624442 1 5/8 SAE 24447 24457 $46.1624444 1-1/4 7/8 IDS 24448 24458 $103.8624445 1-1/4 1-1/8 IDS 24448 24458 $107.70

C BRASS ROTALOCK SPUDMale

No. RL Connection Each24456 3/4 3/8 IDS / 1/2 ODS $38.2824457 1 1/2 IDS / 5/8 ODS $42.3224458 1-1/4 7/8 IDS / 1-1/8 ODS $57.70

TEFLON SEALS FOR ROTALOCKNo. Use with Description Each24446 3/4 Teflon seal $2.5024447 1 Teflon seal $2.7024448 1-1/4 Teflon seal $3.86

Diam Pump Inlet ValveNo. Long Down SAE SAE Each29410 3.5"x10" 3 lbs. 1/4" 1/4" $97.9429411 4"x10" 4 lbs. 1/4" 1/4" $101.5429412 5"x10" 6 lbs 1/4" 1/4" $126.7029413 6"x12" 10 lbs. 3/8" 3/8" $229.3229414 6"x18" 16 lbs. 3/8" 1/2" $296.74

Small receiver has valveswith SAE connections andbottom mounting stud. Inlet isSAE fitting. Each receiver has362°F fusible plug. Pumpdown for R-22 use 90% andfor R-12 use 110% of listing inpounds.

Refrigeration Research Vertical ReceiverWith Valves

Nom Ton FittingNo. Capacity OD Length OD Each29420 5 2" 7-7/16" 5/8" $54.2829421 7-1/2x10 3" 9" 7/8" $94.5429422 10-15 3" 9-1/4" 1-1/8" $86.5029423 15-25 3" 13-3/4" 1-3/8" $100.4829424 25-50 4" 16" 1-5/8" $178.50

Designed to smooth out pulsation and reduce vi-brations

Refrigeration Research Discharge Mufflers

OverallNo. Fig. HP Long Wide High Each29622 A 1 17 7-1/4 3-1/2 $269.5229623 A 1-1/2 17 7-5/8 5-1/8 $338.5429624 A 2 17 7-5/8 6-1/8 $414.5829625 A 3 17 7-5/8 8-3/4 $550.60

29633 B 3/4 10-3/4 9-3/4 3-3/4 $211.0429634 B 1 10-3/4 9-/34 4-5/8 $261.4229635 B 1-1/2 11 10 7-1/4 $431.5829636 B 2 11 10 10 $386.9629637 B 3 13 12 9-1/2 $764.92

29639 C 1 12 12-1/2 2 $232.0829641 C 2 15-3/8 15-3/4 2-1/4 $328.6829642 C 3 15-3/8 15-3/4 2-1/2 $403.84

Refrigerant WaterH.P. Connection Connection3/4, & 1 HP 3/8" ID 1/2" OD1-1/2 and 2 HP 3/8" ID 5/8" OD3 HP 3/8" ID 3/4" OD7-1/2 HP 5/8" OD 1-1/8" OD

Max. Lbs Suction

No. Diam. Lgth. Cap R-12 OD Each29400 4" 6-5/8" 2.3 5/8" $80.4429401 4" 10-5/8" 4.4 5/8" $85.0829402 4" 10-5/8" 4.4 3/4" $91.4029403 5" 13" 7.7 7/8" $137.3229404 6" 15" 12.8 1-1/8" $206.7429405 6" 20-1/4" 17.6 1-3/8" $276.2429406 6" 24-3/4" 22.5 1-5/8" $362.86

Recommended Tons of Refrigerant

Evap R-22 R-12 R-502No. Temp Max Min Max Min Max Min29400 +20°F 1.25 .05 .60 .05 1.0 .0529401 +20°F .55 .05 .25 .05 .45 .0529402 +20°F 2.1 .18 1.15 .12 2.0 .18

–20°F 1.1 .13 .48 .09 .83 .1329403 +20°F 3.0 .45 1.75 .31 3.0 .45

–20°F 1.5 .33 .70 .21 1.25 .3329404 +20°F 6.2 .65 3.2 .44 6.0 .65

–20°F 2.75 .47 1.4 .3 2.5 .4729405 +20°F 11.0 1.9 6.0 1.22 10.0 1.9

–20°F 5.0 1.3 2.4 .85 4.5 1.329406 +20°F 19.0 1.9 9.0 1.22 8.0 1.9

–20°F 8.0 1.3 3.9 .85 7.2 1.3

The suction line accumulator tem-porarily holds the excessive amountsof refrigerant and/or oil that oftenbuild up in the suction line during theoff cycle before they enter the com-pressor. This protects the compressorfrom getting large amounts of liquidon start up and prevents damage. A small hole inthe return tube to the compressor meters the re-turn of liquid, oil, or gas. Hydrogen brazed all steelconstruction. Accumulators should be sized withinlimits of maximum ton based on pressure drop andmin. ton based in oil return and should be able tohold nearly one half the refrigerant charge in thesystem. For vertical mounting with 3/8" stud at thebottom. Refrigerant capacity for R-12 is shown R-22 capacity about 9% and R-502 about 4% less.

Refrigeration ResearchSuction Accumulator

Edwards Counterflow Co-Axial WaterCooled Condensers

A B CA

B C

Switching Relays with operating coils are designedfor standard commercial voltages. Screw terminals.SPNO relay or one pole normally open and onepole normally closed.

FLA 120V 10 amp; 240V 5 amp; 480V 4 amp

Temperature range –40 to 130 degrees F

RBM CoilNo. Steveco Volts Each48333 90-105 24 SPNO $100.46

Switching Relay

No. Mars Each38503 27003 $20.3838505 27005 $19.8038506 27006 $19.8038507 27007 $19.8038509 27009 $19.80

Mars Relay

Cont. P/U Volt. MaxNo. Mars Volt Min. Max. Drop Out Each38563 63 200 139 153 55 $56.7438564 64 432 259 265 129 $77.1238565 65 332 168 182 90 $74.2438566 66 432 215 225 129 $72.7638567 67 457 295 315 125 $77.1238568 68 502 325 345 135 $67.8638569 69 375 180 195 105 $66.6838570 70 253 285 305 77 $58.8238571 71 420 212 232 120 $80.04

Motor Starting Relays

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 16: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

103HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

DEFROST TIMERS

Grasslin Defrost Timer

The DTMV is used in compressor shutdown (air defrost) ap-plications where the space temperature is above freezing(above 32° F, 0° C). It may also be used on electric or hotgas defrost applications where the defrost is terminatedwhen the coil is frost free, as sensed by a temperature orpressure switch, even though the programmed defrost termi-nation time has not been reached.

Defrost Frequency Defrost Minimum DurationNo. Voltage Timer No. / Day Duration Intervals EachDTMV40 120, 208/240 Synchronous 1 to 24 15 to 180 minutes 15 minutes $311.98

DTMV40 replaces the following from Paragon and Precision:Paragon Precision

8141-00 8143-00 8145-008041-00 8043-00 8045-008046-00 8047-00 8141-208143-20 8145-20 8041-208043-20 8045-20 8046-208047-20 8245-20 8243-208247-20

Grasslin Commercial Time Controls

The GM1 and GMD units are universal commercial time switchesthat are field selectable for 120, 208/240, and 277 Volts.

Features:• 30 A, 2 HP @ 240 V switch.• Captive trippers with interval of 15

minutes on 24-hour model.• Easy to set clock face timer.• Optional clear cover allows viewing

timer clock face without opening cover.• One timer replaces 17 competitive models.• No trippers to lose.

• Easy to set — easy to change.

No. Voltage Switch Amps EachGM1STIMV 120, 208/240, 277 SPDT 40 $123.98GM40 120, 208/240, 278 DPDT 40 $170.06

Specifications:• Switch rating:30 A resistive @ 208-250 VAC.2 HP @ 208-250 VAC; 1 HP @ 125 VAC.690 VA pilot duty @ 125-250 VAC.“F” Terminal:10 A Resistive @ 208-250 VAC.1 HP @ 208-250 VAC; 1/2 HP @ 125 VAC.

• Operating temperature range: –40° F to 131° F (–40° C to 55° C).• Operating humidity: 0 to 95% non-condensing.• Dimensions: 10 in. x 6.5 in. x 3.75 in. deep.• Universal replacement.*4 models replace 30 competitive models mounts in existingenclosures standard wiring.

• Defrost times settable on quarter hour.• NEMA 3R outdoor enclosure.• 30 Amp, 2 HP rating.• Electromechanical or electronic.• LED indication of defrost.• Selectable electric/compressor shutdown orhot gas defrost modes.

• U.L. Listed

6141-00 6143-00 6145-006041-00 6043-00 6045-006047-00 6141-20 6143-206145-20 6041-20 6043-206045-20 6047-20 6245-206243-20 6247-20

GMDSTIMV replaces the following:Intermatic Tork ParagonT101 1101 P103T102 1102 P104T103 1103 4003-00T104 1104 4004-71T105 10115-00RS

GM1STIMV replaces the following:Intermatic Tork ParagonT101 1101 P101T101(B) 1102 4001-00T102 8001 4002-71T102(B) 8004 4005-00T105 1015-00RST185T1905T1906

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 17: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

104 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TEMPERATURE & PRESSURE CONTROLS

RANCOAdaptable Ice HarvestControl For Ice Machines

Adaptable replacement for ice machine applica-tions. Low temperature range of-19 to 22 deg F. Differential. Parts and instruc-tions included for easy installation.SPDT switch.

SEE CHART FOR APPLICATION

No. Ranco Each30904 A22-4506 $108.44

RANCODirect ReplacementIce Bin Level Control

Provides narrow 6 deg Fdifferential for accuratecontrol of ice bin level.35 to 51 deg F, with 48"capillary. SPDT switch.

No. Ranco Each30905 A22-1129 $105.20

RANCOCapillary Forming Tool

Makes 3/16" twisted coils 3/8"OD coils and1" OD coils to match coils on control being re-placed so the new control will have the sameoperating characteristics as the old controlbeing replaced 6-5/8" long overall.

No. Each25083 $22.52

RANCOFan Delay Defrost

Termination Control

Prevents Condensationafter defrost cycle.Terminates defrost cycleand delays evaporatorfan operation cycle.This helps prevent condensation being dis-charged into the refrigeration space.Fan On temperature 20 deg Fixed.Defrost: 40 to 75 Adjustable 60" capillary with3/8" x 4" bulb. SPDT.

No. Ranco Each30527 F25-107 $145.94

RANCOTemperature Control forCommercial Applications

General range temperaturecontrols. These controls offera wide selection for suchproducts as self-containedrefrigerators, freezers, cool-ers, walk-in units and refrig-eration display cases.

Universal mounting and compact design.Constant Cut-in settings.

Low Range - SPST (freezer)

Range CapNo. Ranco F Dif F Style Each20708 010-1408 -15 to 40 3 to 20 72" $129.44

w/ bulb

Medium Range - SPST (Refrigeration)Opens Low

Range CapNo. Ranco F Dif F Style Each20711 010-1416 0 to 55 3 to 20 72" $133.26

Cap20714 010-1418 0 to 55 3 to 20 Air $133.26

Coil20709 010-1409 0 to 55 3 to 20 72" $123.22

w/ bulb

Medium Range - SPST (Refrigeration)Opens High or Low

Range CapNo. Ranco F Dif F Style Each30515 016-104 0 to 55 3 to 20 72" $138.98

w/ bulb

High Range - SPST(Cooling & Condenser Fans)Opens Low

Range CapNo. Ranco F Dif F Style Each20710 010-1410 25 to 75 3 to 20 72" $130.88

w/ bulb

RANCO ElectronicTemperature Control

RANCO ETC is an elec-tronic temperature controldesigned to provide on/offcontrolfor commercial heating,cooling, air conditioning,and refrigeration applica-tions.With its wide temperaturerange, selectable heat-ing/cooling modes andmulti-voltage input.

Temperature setpoint range -30F to 220F. Dif-ferential range 1F to 30F. Input poweris 120 or 208/240VAC (24VAC optional).Sensor is 2" long x 1/4" dia. with 8ft cable.

No. Ranco Switch Each20713 ETC-111000-000 SPDT $116.04

RANCOWide Range Control

RANCO Wide RangeControl offers the ulti-mate in expanded widerange temperature con-trol. It features a gas-filled, non-positionssensitive cross ambientbulb. It is virtually unaf-fected by ambient tem-perature and sensesfrom the bulb only.

Suitable for return air or space temperaturesensing, defrost termination, fan delay, andevaporator coil sensing. Can also be used formost heating and industrial equipment applica-tions. SPDT switch.

No. Ranco Range F Dif F Cap Each20777 060-100 -35 to 95 4 to 50 96" $118.64

20778 060-101 -35 to 95 5 to 50 Air $136.70Coil

RANCOCommercial Controlwith Constant Differential

OEM equivalent cold controls for vending ma-chines, beverage coolers, freezers, and othercommercial applications. SPST with off posi-tion. Cap 48"

No. Ranco Range F Dif F Each30900 A30-323 -11 to 10.5 10 $110.4230901 A30-2209 35 to 46 8 $102.2030902 A30-2210 30 to 42 8 $83.0430903 A30-2211 -10.5 to 17.5 10 $83.80

Refrigeration Controlwith 8 foot Element

No. Range Each73671 -30 F to 90 F $100.20

Remote mounting refrigeration temperaturecontrol with a -30 deg F to90 deg F temperature range and 3-1/2" to 12deg F adjustable differential' with SPDT microswitch rated at8 Amp 120V or 5.1 Amp 240V. Used to controleither on temperature rise or temperature fallfor units as different as ducts, tanks, freezers,or coolers. Model T6031A1029

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 18: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

105HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

AIR CONDITIONING CONTROLS

Self-RegulatingCrankcase Heater

FreezGard self-regulatingcrankcase heaters providereliable peak heating dur-ing cold periods and re-duce there heat oncecompressor starts up orair temperature rises.

The heaters can be over-lapped and closely spacedwithout burning out.

One size fits all hermetic compressors upto 40" in circumference.32 watts at 50 deg F and 50 watts at 0 deg F.

No. Volt Watt Circumference Each28160 120 60 40" Max $115.2828161 240 60 40" Max $135.84

Crankcase Heater

These crankcase heaters are for air conditioningand refrigeration. Completely moisture proof.Installs quickly and easily.

Used on Compressor Models:65254 & 50: Tec-AH, AG, AV

Cope-VR, Y, YRBR8-H20A

65251: Tec-AJ,BRS-H10C, H20C-H22C

65252: Tec-AB, AWCope-RR, SRBRS-H20B-H22B

CircumferenceNo. Volt Watt Min Max Each65254 120 54 27-7/16" 34-1/4" $40.9065250 240 54 27-7/16" 34-1/4" $4.6665251 240 60 25-3/4" 32-9/16" $38.6465252 240 45 24-3/4" 31-9/16" $38.64

RANCOAir ConditionerLow Ambient Thermostat

Prevents thecompressor

from operating when outside temperatures arelow.

Prevents damage from possible liquidreturn in suction lines.

5" Differential,50 to 65 deg F cut out range.24" Cap.

No. Ranco Each30538 A30-X204 $108.50

RANCO4-Way Reversing Valve

These solenoid coil-operated reversingvalves are slide type,4-way with a 4-wayvalve and operateunder the full pressureof a heat pump sys-tem. These valves areused on unitary, split system,and window-type heat pump applications.

Cap.(Tons) Tube Tube

No. Ranco R22 Outlet Inlet Each24993 V6-2101 1 to 5.5 3/4" 1/2" $238.5624994 V10-2500 3 to 8.5 7/8" 1/2" $337.26

Solenoid CoilsLDK Solenoid Coils(For Reversing Valves)

Type LDK solenoid coils are designed for use

with current production ('Generation 4") V0, V1,V2, V3, V6, V10 and V12 RANCO Heat PumpReversing Valves.

No. Ranco Voltage Each73758 LDK-110000-070 24 V $78.5673759 LDK-310000-070 120 V $79.1073757 LDK-410000-070 208/240 V $76.92

Solenoid CoilsL30 Solenoid Coils(For Reversing Valves)

No. Ranco Voltage Each24985 L30-0024 24 V $63.3824987 L30-0240 208/240 V $62.24

Single and Two Stage Controlsfor Packaged Terminal Room andThrough the Wall Heat/Cool Units

24990 has 26" capillary with 8-9/16" x 3/8" bulb.

No. Ranco Range Switch Each24990 C17-100 71-101 Clg (2) SPDT $154.10

64-94 Htg

RANCOAdaptable ReplacementCycling Controls forRoom Air Conditioners

Adaptable control to re-place OEM controls whichgovern the on/off com-pressor function.

Includes break-offshaft, dial knob,mounting bracket, andinstallation instructions.

Cooling - SPST Switch

No. Ranco Cap Each18" Air

25080 A30-X450 Coil Bulb $66.14

36"25081 A30-X451 Straight $66.14

39"25082 A30-X452 Bulb $72.60

Cooling Switch - SPDT

No. Ranco Cap Each27"

30598 A22-2451 Straight $99.82

39"30599 A22-2453 Bulb $122.00

Oil Pressure Safety Control

No. Alco Press Time201000A FD113-ZUK 4-65 PSID 20 to 150

sec.Voltage Conn Each24 to 240 (2) 36" Cap $412.46V AC/DC with flare nut

White-Rodgers HydraulicAction Temperature Control

The element providesclose-differential control,positive accuracy at anytemperature in the dial range.Calibrated evenly andaccurately in F deg, it can bemounted in any position or anyangle. quickly and easilyadjusted with a screwdriver. Has range of 30deg F to 90 deg F with adjustable differentialof 3 deg F to25 deg F with 5 ft. tube and5-3/4" x 3/8" bulb.

No. Model Each21303 1609-101 $86.92

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 19: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

106 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

TEMPERATURE / PRESSURE CONTROLS

RANCOConstant Cut-in ControlOff-Cycle Defrost

This constant cut-in design is used to providean off-cycle defrost. When the control cyclesoff the contacts remain open until the evapora-tor is cleared of any frost that may have accu-mulated from the previous on cycle. Forvending machines, beverage dispensers andreach-in coolers.

No. Ranco Range F Cut In Cap Each30596 A12-700 11 to 27 37 84" $101.8030597 A12-701 15 to 31 41 84" $104.2020629 A12-1506 9 to 22 38 30" x 3/8" $105.9825000 A12-1560 19 to 29 39 76" $101.00

RANCOCommercial Direct ReplacementOEM Controls

These direct replacement controls are for commercial refrigerators,freezers, ice machines, vending machines and beverage coolers. A wide selection of temperature ranges, differentials and capillary length.Break off shafts are included with installation instruction for easy fast in-stallations. Control has an off position except where noted with (*) haveNO off position. SPST.

Refrigerator Controls

No. Ranco Range F Dif. F Cap Each25064 A30-180 -4 to 38 13 42" $79.6025061 A30-181 -4 to 41 13 84" $103.0025065 A30-182 -6 to 44 17 42" $97.5825063 A30-183 -6 to 44 17 84" $103.6625062 A30-184 -7 to 40 19 42" $64.5425060 A30-185 -15 to 36 16 42" $94.8230906* A22-1112 25 to 44 5 72" $98.8030907* A22-391 11 to 51 8 66" $121.4830908* A22-392 14 to 62 24 48" $132.38

Refrigerator/Freezer Controls

No. Ranco Range F Dif. F Cap Each25070 A30-301 -24 to 20 8 84" $41.1925072 A30-304 -21 to 19 15 84" $80.3230909 A30-310 -24 to 23 20 36" $80.3230910 A30-311 -22 to 23 14 42" $99.1430912 A30-313 -20 to 21 8 42" $84.44

RANCODual Function Pressure Control

These dual function pressure controls offera tailored variety of ranges and options forrefrigerants. Low and High pressure func-tions are combined into a single control with one switch.

Dual FunctionSPST - Automatic Reset

Lo/Hi Lo/Hi Range Diff. Conn.

No. Ranco (PSIG) (PSIG) Style Each20723 012-1505 12" to 50 5 to 35 Male Flare $234.50

100 to 250 50 Fix20602 012-1506 12" to 50 5 to 35 36" Cap $248.58

100 to 250 50 Fix30544 012-1502 12" to 50 5 to 35 36" Cap $248.52

150 to 450 70 Fix20676 012-1549 10" to 100 10 to 40 36" Cap $234.68

150 to 450 70 Fix

Convertible ResetAllows for manual reset, auto high pressure reset, or auto low pressurereset.

Lo/Hi Lo/Hi Range Diff. Conn.

No. Ranco (PSIG) (PSIG) Style Each25007 022-7702 12" to 50 5 to 35 36" Cap $314.12

100 to 250 50 Fix20771 012-4833 12" to 50 5 to 35 48" Cap $241.94

100 to 250 70 Fix20772 012-4834 10" to 100 10 to 40 48" Cap $229.94

150 to 450 70 Fix25008 022-7706 10" to 100 10 to 40 36" Cap $316.12

150 to 450 60 Fix

RANCOControl for Beverageand Water Coolers

No. Ranco Range Dif. Cap Each25066 A30-260 .5 to 30 6 72" $89.0025067 A30-261 32 to 61 6 84" $77.0825069 A30-263 .5 to 47 22 84" $82.82

Dual Pressure Control

Low Low High Low No. Alco Press Diff Press Press201020A PS2-Y7K 24 to 42 3 to 30 90 to 450 60 Fixed

LP Switch HP Switch Conn EachLP SPDT Auto reset HP SPDT Convertible (2) 48" Cap with $323.14

1/4" Flare nuts

Ref

rig

erat

ion

Page 20: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

107HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

PRESSURE CONTROLS

RANCOMini Encapsulated Pressure ControlsLow & High Pressure

Mini Pressure fixed setting controls are used on refrigeration and air condi-tioning systems. 48", 18 AWG leads with 1/4" SAE female flare fitting withvalve core depression. 10 amps at 120 volt, 5 amps at 240 volts

Low PressureNo. Model No. Switch Cut-Out Cut-In Each21620 MPL-7011 SPST 10 25 $44.2421621 3100-051 SPST 25 80 $42.5221622 MPL-7014 SPST 40 80 $42.52

High PressureNo. Model No. Switch Cut-Out Cut-In Each21637 3100-080 SPST 210 275 $42.7621630 3100-150 SPST 350 250 $44.2421631 3100-151 SPST 400 300 $44.2421633 3100-100 SPST 425 325 $44.2421638 MPH-7110 SPDT 410 Manual $58.24

RANCOSingle Pressure Controls forCommercial Applications

Ranco "O" type controls feature lazer-welded steel bellows for long life.Its rugged construction includes a heavy steel frame, precision groundsprings and tempered steel mechanisms, industry-standard mountingand compact design. Mounting bracket included.

SPST - Opens LowNo. Ranco Range (PSIG) Diff (PSIG) Conn. Style Each20715 010-1401 12 to 50 5 to 35 Male Flare $111.8820716 010-1402 12 to 50 5 to 35 36" Cap $123.3820675 010-1483 10 to 100 10 to 40 36" Cap $129.8624949 010-1894 100 to 400 40 to 150 Male Flare $112.9625009* 010-2054 100 to 400 40 to 150 36" Cap $124.46* Can be used as Fan Cycling

12 to 50 Low Pressure for R-12, R-134A10 to 100 Low Pressure for R-22, R-502

SPST - Opens HighNo. Ranco Range (PSIG) Diff (PSIG) Conn. Style Each20770 011-3099 10 to 100 10 to 40 36" $134.2220672 011-1711 150 to 450 50 to 100 36" $139.44

SPDT - Opens High or Low

No. Ranco Range (PSIG) Diff (PSIG) Conn. Style Each20696 016-107 10 to 100 10 to 40 Male Flare $129.9430520 016-527 10 to 100 10 to 40 36" Cap $148.2620698* 016-108 100 to 400 40 to 150 36" Cap $135.6425096 016-200 150 to 450 Man. Reset 48" Cap $147.26* Can be used as Fan Cycling

12 to 50 Low Pressure for R-12, R-134A10 to 100 Low Pressure for R-22, R-502

RANCOHigh-Low Pressure Cycling Control

Cut-Out DiffNo. Ranco (PSIG) (PSIG) Reset Each30602 G20-4050 7 to 27 12 Fix Auto $92.7030603 G20-4051 7 to 77 19 to 70 Auto $98.0230605 G20-4412 7 to 70 17 Fix Manual* $64.2230604 G20-5052 150 to 450 50 to 150 Auto $105.2630606 G20-5253 150 to 450 105 Fix Manual** $105.26* Locks on pressure decrease** Locks on pressure increase

These controls protect against compres-sor failure due to freeze-up from refriger-ant loss.It can also be used to provide pressurebuild-up wen required or desired.Type G20 — Protects against loss ofcharge or evaporator freeze-up.Type G23 — Provides high head pres-sure protection.SPDT

High Pressure Controls

No. Alco Press Diff Switch Conn Each201015A PS1-X5K 90 to 450 30 to SPDT 36" Cap $171.90

220 Auto reset with 1/4'Flare nut

Low Pressure Control

No. Alco Press Diff Switch Conn Each201005A PS1-X3K 15 to 100 7 to 70 SPDT 36" Cap $171.90

Auto reset with 1/4'Flare Nut

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 21: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

108 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

HARDWARE

58 SafeGuard Latches

No. Kason Description Each

17131 58L-5021 Handle $214.5817132 59-5001 -1/8 to 1/4" stk $75.7417133 59-5002 3/4 to 1-1/2" stk $72.1217134 481C600 Push Rod $32.66

This safety latch features a radial tonguewhich rolls securely into closed position.

Combine this easy-operating latch with an in-side release to provide necessaryemployee protection.

3 pound spring pressure.

Pacesetter Handle and Hinges

No. Kason Description Each

17123 1239CV-05 Handle Assb $262.48

The economical Pacesetter handle offers a newconcept in walk-in hardware design.

It releases from the outside with minimum pull.

Handle comes complete with insidesafety release.

930 Surface Mount Latch

533D Edgemount Mechanical Latch

No. Kason Description Each

17129 174-04 Latch with strike $97.24Offset Adj 13/32 to 23/32

Latch body with adjustment plate and strike.

No. Kason Description Each

17117 931-016 Latch $350.6617118 931-024 7/8 to 1-1/2" Strike $80.00

Similar to above but an enlarged version forlarge reach-in doors.

56 SafeGuard Latch

No. Kason Description Each

17120 56L5020 Latch $373.4817121 56-5003 -1/2 to 1/4 stk $117.7017122 5605002 3/4 to 1-1/2 stk $133.5017124 481A600 Push Rod $30.82

Kason SafeGuard latch has an inside releasewhich will open the door even when latchis locked, padlocked or cylinder locked.

27 pound spring pressure.

55 SafeGuard Latch

No. Kason Description Each

17125 55-028 Latch $1,026.3217126 55-112 -1/2 to 1-5/8" str $353.7817128 483-04 Push Rod $45.40

Latch completely equipped with a surfacemounted paddle style inside release leverthe 55 easy style latch releases for insideor outside with minimum pressure or pull.

For Other Kason

Hardware Contact

One of Our

Harry Alter Co.

Store Locations

No. Kason Description Each

17105 533D-04 Latch $119.90

Powerful smooth operating latch with two waymicro turn strike.

A turn of the strike insert adjusts tension whenthe gasket becomes worn.

The serrated adjustment plate allows up or downadjustment to correct door sag.

174 Edgemount Mechanical Latch

The 930 dependable trigger action latchesinstall on right or left hand opening doors.

Microturn strike for fine adjustments.

No. Kason Description Each

17114 930C-20 Latch $194.2017116 930C-08 3/4 to 1-1/4" Strike $142.36

Latch

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 22: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

109HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

HARDWARE

1070 Surface Mount Hinges

No. Kason Offset Each17166 1070-04 Flush $72.74

212, 217, 218 Edgemount Hinge

No. Kason Offset Each17148 212-08 1-1/8 $36.3217150 217-08 1-1/3 $59.32

This edgemount adjustable hinge for right orleft opening door.Easily adjustable to take up play in door.

Food Grade Silicone

No. Color Temperature EachCaulk Clear Clear -50 to 450 deg F $5.88Caulk Red Red -65 to 650 deg F $9.94

Silicone adhesive sealant forFood Service air cures to a tough flexi-ble solid in 24 hours, tack freein 15 minutes.

Cylinder fits in standard caulking guns.

Thermal Flex Strip Curtains

No. Curtain Size Each96852 38x84x6 $277.5096853 46x90x6 $509.74

1094 Hydraulic Door Closer

No. Kason Door Closer Each17184 1094-03 Exposed Mt. $284.6617183 1094-13 Concealed Mt. $299.8617185 1094-25 Hook Flush $23.9817186 1094-29 Hook 1-18 $31.90

1245 and 1248 Cam-Rise Hinges

No. Kason Offset Each17160 1245-28 Flush $264.0017161 1245-40 1-1/8 $178.2017162 1245-44 1-1/4 $119.98

No. Kason Offset Each17163 1248-04 Flush $196.36

You can count

on us for

Totaline Factory

Authorized Parts.

No. Kason Offset Each17152 218-08 1-1/8 $111.82

Similar to above with adj. springIdeal for use with self-closing refrigerator doors.Features powerful spring tension that adjustseasily to provide required closing forces.Offsets easily adjusted. 1092 Hydraulic Door Closer

No. Kason Door Closer Each720960 1092-08 1-1/8 Offset $210.50720865 1092-04 Flush $180.82

1097 Heavy Duty Door Closer

No. Kason Door Closer Each17187 1097-04 Door closer $1,054.20

Specifications:6" inch wide .060 GaugeTemperature Range -20 to 140 deg. F.

General Applications:Walk-in coolers and freezers, refrigerated truckbodies within temperature range. Industrial en-closures, dust or noise control for machinery.Room divisions.

Instructions:Measure width and height of opening.Add minimum 4 inches to the width and 6inches to the height to determine curtain size.

This heavy duty high tension door closer attachesto the door frames.

Recommended only for doors exceeding 200 lbs.

Recommended mounting is just abovelower hinge.

This hydraulic closer brakes movement, shutsdoor silently and keeps it closed.

Will reclose doors which may have popped openas a result of temperature-pressure buildup.

Solid, heavy duty construction with the bend proofhook.

Sure closing and self correctingto overcome alignment problems.

Reversible cam rise hinges.Recommended Allowable Load.

100 lb. door up to 72" wide.200 lb. door up to 39" wide.300 lb. door up to 24" wide.

Recommended allowable load.20 lb. door up to 72" wide.40 lb. door up to 33" wide.

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 23: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

110 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

Ref

rig

erat

ion

DuPont Refrigerants developed the DuPont Refrigerants P/T Calc App as a way to help contractors and end users move from the P/T chart of yesterday to the technology of today with this easy to use app. The app is available to download on the iPhone, iPad and iPod Touch.

The app includes P/T data for the entire family of DuPont refrigerants products. Information available for each refrigerant includes: % composition, physical, chemical, environmental properties, temperature glides, typical use applications and lubricant recommendations. The app provides

product information and links to DuPont Refrigerants web site. In addition, the app automatically calculates superheat and subcooling.

The DuPont Refrigerants P/T Calc app is a free app and can be installed from this link: http://itunes.apple.com/us/app/dupont-pt-calc/id480622238?ls=1&mt=8

or scanning this QRCode:

Ref

rig

erat

ion

Page 24: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

111HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

REFRIGERANTS

R-401ASuva MP39 is the recommended alternative for medium and low temper-ature R-12 systems, such as reach-in and walk-in coolers, food and dairydisplay cases, beverage dispensers vending machines, and home refrig-erators.Recommended Evaporator Temperatures -10 deg F & above.

No. Ashrae SUVA Cyl Size Oil Type Replaces09063 R-401A MP39 30 lb. AL; POL R-1209062 R-401A MP39 125 lb. AL; POL R-12

R-401BSuva MP66 is available for R-12 systems operating at low evaporatortemps, below -15 deg F where higher capacity is needed such as somedomestic and commercial freezers and some transport refrigerationequipment. MP66 is also the recommended replacement for existing R-500 systems.Evaporator Temperatures -10 deg F & below.

No. Ashrae SUVA Cyl Size Oil Type Replaces09070 R-401B MP66 30 lb. AL; POL R-12 &

R-500

R-409ASuva 409A is a replacement option for R-12 medium and low tempera-ture refrigeration and air conditioning sytems using positive displacementcompressors with direct expansion evaporators.Evaporator Temperatures -10 deg F & above.

No. Ashrae SUVA Cyl Size Oil Type Replaces09036 R-409A 409A 30 lb. AL; POL R-12

R-134aSuva 134a is the commercially available refrigerant for use as a long-term replacement for R-12 in new equipment and for retrofitting mediumtemperature CFC-12 systems.Evaporator Temperatures 20 deg F & above.

No. Ashrae SUVA Cyl Size Oil Type Replaces09061 R-134a 134a 30 lb. Polyol ester R-1209064 R-134a 134a 125 lb. Polyol ester R-12

R-22Freon R-22 is an HCFC refrigerant and has been commercially availablefor use in various refrigeration, industrial cooling, air conditioning andheat pump applications.

No. Ashrae Freon Cyl Size Oil Type Replaces09020 R-22 R-22 30 lb. M; AL; POL N/A09008 R-22 R-22 50 lb. M; AL; POL N/A09009 R-22 R-22 125 lb. M; AL; POL N/A

R-410ASuva 9100 is being positioned by manufacturers as a replacement forHCFC-22 in residential air conditioners and heat pumps because of op-portunities for improved efficiency versus HCFC-22. Because of thehigher operating pressures of Suva 9100 its application will be in newequipment designed specifically for this new refrigerant.

No. Ashrae SUVA Cyl Size Oil Type Replaces09032 R-410A 9100 25 lb. Polyol ester R-22

R-402ASuva HP80 offers the best combination of properties for most applica-tions. It has discharge temperatures and efficiency comparable to R-502,but with improved capacity. Can be used in walk-in coolers and freezers,frozen food and dairy display cases, ice cream dispensers, beveragevending machines and some transport refrigeration equipment.Temperatures -40 deg F & above.

No. Ashrae SUVA Cyl Size Oil Type Replaces09069 R-402A HP80 30 lb. AL; POL R-502

R-402BSuva HP81 is recommended for applications where an increase in com-pressor discharge temperature of 10 to 20 deg F is acceptable, such asice machines, open drive compressor systems, water cooled condensingunits and compressors operating in low ambient temperatures.

No. Ashrae SUVA Cyl Size Oil Type Replaces09068 R-402B HP81 13 lb. AL; POL R-502

R-408ASuva 408A has lower operating pressures than Suva HP80 and SuvaHP81 with lower capacity and equal or higher discharge temperaturesthan HP81. Suva 408A is suitable for use in older equipment where con-denser size may be limited.

No. Ashrae SUVA Cyl Size Oil Type Replaces09038 R-408A 408A 24 lb. AL; POL R-502

HP62Suva HP62 is the commercially available refrigerant for use as a long-term replacement for R-502 in new equipment and for retrofitting mediumand low temperature R502 applications.HP62 is is comparable to R507.

No. Ashrae SUVA Cyl Size Oil Type Replaces09072 R-404A HP62 24 lb. Polyol ester R-50209071 R-404A HP62 12 lb. Polyol ester R-502

R-508BSUVA 95 is for use in cascade systems. These applications typically op-erate with evaporator temperatures between -40 deg to -150 deg F andinclude environmental test chambers, constant (very low) temperaturefreezers and process cooling.

No. Ashrae SUVA Cyl Size Oil Type Replaces09076 R-508B 95 10 lb. Polyol ester R-50309077 R-508B 95 20 lb. Polyol ester R-13 & R-23

R-414B (Hot Shot)Trade name Hotshot for use as an R-12, R134a and R500 replacementoption for medium and low temperature ranges.

No. Ashrae Name Cyl Size Oil Type Replaces09041 R-414B Hot Shot 30 lb. M; AL; POL R-1209042 R-414B Hot Shot 120 lb. M; AL; POL R500, R134a

Oil TypesM = Mineral AL = Alkylbenzene POL - Polyol ester

All information is for reference only.Contact the refrigerant or the compressor manufacturer for complete retrofit guidelines.Other SUVA refrigerants available direct from Manufacturer. Please call for pricing.

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 25: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

112 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

THERMOSTATIC EXPANSION VALVES

The Factory Authorized Parts Difference

F.A.P. TXVsThermostatic Expansion Valves

Has balanced port design and allows TXV to be independent of high ambient conditions and reduces the risk of oversized valve.

Majority of F.A.P. TXVs have a bleed port (some-times rapid pressure balancer) ranging from 5%to 40%, which in addition to equalization provides5% to 40% extra capacity.

Majority of F.A.P. TXVs are non-adjustable - set tospecial superheat setting to keep evaporator coilcompletely refrigerated under Carrier Corporationdesign conditions.

Proper subcooling is specified for CBP equipmentand usually is a part of data plate and technicalspecifications. Sizing of the valve reflect unit design to provide adequate amount of subcooling.

Very stringent internal leakage and external leakage requirements. Valve to satisfy reliability requirementsper Carrier Reliability Requirement CC14DC511

Always matches CBP system design require-ments. Majority of valves have extended connec-tions which makes brazing much easier.

Presence of built in check valve assures bi-flowcapability.

Preset - no adjustable stems on product

Reduce risk of damaging valve's interior parts andthermostatic element with a torch flame.

100,000 cycles; 15 years.

Aftermarket TXVsThermostatic Expansion Valves

Often have a fixed orifice design for majority of airconditioning valves. Fixed orifice valves are not aseffective at high ambient conditions and may nothandle reduced load.

Aftermarket valves generally do not have bleedports or rapid pressure balancers in their standardoffering. If bleed port option exists, it is often diffi-cult to match correct percentage of bleed to F.A.P.design. Aftermarket valves generally do not havebleed port/rapid pressure balancer feature.

Adjustable valve with "aftermarket" setting cancreate load fluctuations. Factory superheat setting does not normally match the seeting of the F.A.P. valve.

Aftermarket valves generally do not considerspecifics of CBP units design and use "standard"values for pressure drop in valve selections.

Internal valve design for aftermarket valves is according to valve manufacturer's specificationsonly, not according to CBP system design

Generally use only one set of standard connec-tions for different valves. If available, specialconnections are usually non-stock and availablewith additional lead time.

Aftermarket valves usually do not have built incheck valve.

Adjustable stem can add 1"-2" to the height of thevalve which could be a problem in a limited space.

Not all aftermarket valves have extended connections.

Different valve manufacturers specify their own design life requirements

FeaturesBalance port/Pressuredrop across valve

Bleed port and /or rapidpressure balancer

Superheat Adjustment

System charging

Internal valve design

Connections

Built-in check valve

Superheat Adjustment

Extended connections

Design life

SystemPerformance

System

Reliability

System

Reliability

Installationand

Serviceability

Safety

Thermostatic Expansion ValvesFactory Authorized Parts Training GuideFactory Authorized Parts are designed to meet exact Carrier® Corporation specifications, ensuring optimum system performance, proven reliability, easy installation and maintenance and safe system operation.

Sales CentersReplacement Components Division • © Carrier Corporation 2011 Printed in the U.S.A. • Edition Date: 04/2011For promotional information visit www.totaline.com and for technical information visit www.hvacpartners.com Lit. No.: 570-941

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 26: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

113HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

EXPANSION VALVES

No. ALCO Tons Ref Each200354A TCLE 3 FC 3 R-12 $216.62200324A TCLE 3 HC 3 R-22 $216.62200325A TCLE 5 HC 5 R-22 $216.62200355A TCLE 6-1/2 FC 6-1/2 R-12 $216.62200356A TCLE 7-1/2HC 7-1/2 R-22 $216.62200330A TCLE 10 HC 10 R-22 $216.62200331A TCLE 12 HC 12 R-22 $216.62200332A TJRE 14 HC 14 R-22 $410.78200363A TJRE 18 HC 18 R-22 $410.78200364A TER 22 HC 22 R-22 $556.92200365A TER 26 HC 26 R-22 $556.92200366A TER 35 HC 35 R-22 $556.92200368A TIR 55 HC 55 R-22 $844.30200369A THR 75 HC 75 R-22 $844.30

(200370 replacement gaskets for all T series valves)

Body Flanges

Flanges for TCL,TCLE, TL & TLE ValvesNo. ALCO Inlet Outlet Style Each200420A C-500-4 3/8 sae 1/2 sae Angle $23.02200421A C-501-4 3/8 ODF 1/2 ODF Angle $23.02200425A 9761-4 1/2 ODF 5/8 ODF Straight $23.02200422A X6346-17 5/8 ODF 7/8 ODF Straight $23.02200423A X6346-34 7/8 ODF 1-1/8 ODF Straight $23.02

Flanges for TER valves200424A 9152 7/8 ODF 1-1/8 ODF Straight $88.42200426A 9153 7/8 ODF 1-1/8 ODF Angle $88.42

Capscrews for flanges200920A PS286-5 Capscrew for TCLE valves $1.06200921A PS250 Capscrew for TER & TJR $2.54

Features, Advantages & Benefits• Take-A-Part construction for easy servicing.• External superheat adjustment.• Interchangeable, replaceable cages for TEV versatility

(1/4 to 100 tons capacity).• Interchangeable body flange for any connection you need.• Interchangeable power heads for R12, R22, & R502 refrigerants.• Contoured, durable power element for long life.• Charges for all applications.• Safe working pressure:450 psig.• Safe working temperature: 250°F

Power Assemblies for T-Series Valves

For TCLE, TJLE and TJRE ValvesNo. ALCO Ref Length Each200400A XB-1019 FC 1 B R-12 5 ft. Cap Tube $160.58200401A XB-1019 HC 1 B R-22 5 ft. Cap Tube $160.58200402A XB-1019 HC 2 B R-22 10 ft. Cap Tube $160.58200403A XB-1019 RC 1 B R-502 5 ft. Cap Tube $160.58

For TER, TIR, and THR Valves200406A XC-726 FC 2 B R-12 10 ft. Cap Tube $477.96200407A XC-726 HC 2 B R-22 10 ft. Cap Tube $477.96200408A XC-726 RC 2 B R-502 10 ft. Cap Tube $477.96

For TLE Valves: Non-Adjustable200405A XB-1033 HC 1 B R-22 5 ft. Cap Tube $149.54

Expansion Valve PartsPart No. Alco No. Description Models used on Each200370A X-13455-1 Gasket Kit T series exp valves $5.26200920A PS286-5 Cap screw ea. TCL, TCLE, TL, TLE $1.37200921A PS259 Cap screw ea. TJR, TER $3.16

Cages for T-Series Valves

For TCLE ValvesR502

No. ALCO R-12 R-134a R-22 R404/R507 R407C Each200413A X22440 B2B 1/2 3/4 1 1/2 1 $46.78200414A X22440 B3B 1 1-1/2 2 1 2 $46.78200415A X22440 B4B 2 2-1/2 3 2 3 $46.78200416A X22440 B5B 3 3-1/2 5 3 5 $46.78200417A X22440 B6B 4 5-1/2 7-1/2 4-1/2 7-1/2 $46.78200418A X22440 B7B 6-1/2 7-1/2 10 7 10 $46.78200419A X22440 B8B 7-1/2 9 12 8 12 $46.78

For TER ValvesR502

No. ALCO R-12 R-134a R-22 R404/R507 R407C Each200409A X-9117-B6B 13 16 22 14 22 $241.14200410A X-9117 B7B 15 19 26 16 28 $241.14200411A X-9117 B8B 20 25 35 21 35 $241.14200412A X-9117 B9B 25 31 45 27 45 $241.14

Interchangeable PowerHeads for R-12, R-22, andR-502 refrigerants.

Interchangeable Cagesfor 1/4 to12 ton capacity.Single port constructionshown here.

Interchangeable BodyFlanges for any connec-tion you need.

T-SERIES Expansion Valves

T-Series valves are sold less flanges and are external equalized.The valves consist of powerhead and cages.

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 27: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

114 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

EXPANSION VALVES

Emerson Expansion Valves

Super HF Balanced Port TXVSuper HF thermostatic expansion valves feature a balanced port con-struction whichprovides stable and accurate superheat controlover a wide range of operating conditions. Whether your application iscommercial refrigeration or HVAC, Emerson's HF will increase your sys-tem’s stability.

R12, R134A, R401A Internal EqualizedNo. Emerson Refg Ton Inlet Outlet Each200300A HF 1/4 FC R-12 1/4 3/8 sae 1/2 sae $114.60200301A HF 1/2 FC R-12 1/2 3/8 sae 1/2 sae $114.60200346A HF 1 FC R-12 1 3/8 sae 1/2 sae $114.60200303A HF 1-1/2 FC R-12 1 1/2 3/8 sae 1/2 sae $114.60

R12, R134A, R401A External EqualizedNo. Emerson Refg Ton Inlet Outlet Each200308A HFE 1/2 FC R-12 1/2 3/8 sae 1/2 sae $124.96200349A HFE 1 FC R-12 1 3/8 sae 1/2 sae $124.96200931A HFE 1-1/2 FC R-12 1 1/2 3/8 sae 1/2 sae $124.96200395A HFE 2 FC R-12 2 3/8 sae 1/2 sae $124.96200311A HFE 3 1/2 FC R-12 3 1/2 3/8 sae 1/2 sae $127.94

R22, R407C, 408A External EqualizedNo. Emerson Refg Ton Inlet Outlet Each200357A HFE 1/2 HC R-22 1/2 3/8 sae 1/2 sae $124.96200358A HFE 1 HC R-22 1 3/8 sae 1/2 sae $124.96200350A HFE 1-1/2 HC R-22 1 1/2 3/8 sae 1/2 sae $124.96200359A HFE 2 HC R-22 2 3/8 sae 1/2 sae $124.96200450A HFE 3 HC R-22 3 3/8 sae 1/2 sae $124.96200313A HFE 5-1/2 HC R-22 5 1/2 3/8 sae 1/2 sae $127.94

R502, R404A, R402A, R507 Internal EqualizedNo. Emerson Refg Ton Inlet Outlet Each200376A HF 1/4 RC R-502 1/4 3/8 sae 1/2 sae $114.60200340A HF 1/2 RC R-502 1/2 3/8 sae 1/2 sae $114.60200348A HF 1 RC R-502 1 3/8 sae 1/2 sae $114.60

R502, R404A, R402A, R507 External EqualizedNo. Emerson Refg Ton Inlet Outlet Each200351A HFE 1 RC R-502 1 3/8 sae 1/2 sae $124.96200396A HFE 2 RC R-502 2 3/8 sae 1/2 sae $124.96200320A HFE 3 1/2 RC R-502 3 3/8 sae 1/2 sae $127.94

With Pressure LimitingNo. Emerson Refg Ton Inlet Outlet Each200472A HFE 1/4 RW45 R-502 1/4 3/8 sae 1/2 sae $124.96200473A HFE 1/2 RW45 R-502 1/2 3/8 sae 1/2 sae $124.96200471A HFE 1 RW45 R-502 1 3/8 sae 1/2 sae $124.96200397A HFE 2 RW45 R-502 2 3/8 sae 1/2 sae $124.96200392A HFE 3 1/2 RW45 R-502 3 1/2 3/8 sae 1/2 sae $127.94HF: Internal Equalized HFE: External Equalized

Evaporator Bulb Charge Code RefrigerantTemperature R-12 R-22 R-502

Med temp (-20 to +50 deg F) FC HC RCLow temp (-50 to +10 deg F) FZ HZ RZMOP low temp (-50 to deg F) FW15 HW35 RW45

MOP med temp (0 to +25 deg F) ____ HW65 RW65

HFE

HFSC has all the features of the HFstylevalve. This sweat valve has a strainer atthe inlet which can be cleaned and or re-placed without removing the valve.

R-22 Internal Equalized

No. Emerson Refg Ton Inlet Outlet Each200435A HFSC 1/4 HC R-22 1/4 3/8 OD 1/2 OD $150.62200436A HFSC 1/2 HC R-22 1/2 3/8 OD 1/2 OD $150.62200437A HFSC 1 HC R-22 1 3/8 OD 1/2 OD $150.62

R-22 External EqualizedNo. Emerson Refg Ton Inlet Outlet Each200440A HFESC 1/2 HC R-22 1/2 3/8 OD 1/2 OD $168.60200441A HFESC 1 HC R-22 1 3/8 OD 1/2 OD $168.60200442A HFESC 1 1/2 HC R-22 1 1/2 3/8 OD 1/2 OD $168.60200443A HFESC 2 HC R-22 2 3/8 OD 1/2 OD $168.60200444A HFESC 2 1/2 HC R-22 2 1/2 3/8 OD 1/2 OD $168.60200445A HFESC 3 HC R-22 3 3/8 OD 1/2 OD $168.60200446A HFESC 5 1/2 HC R-22 5 1/2 3/8 OD 1/2 OD $168.60

AFA Series Expansion Valve

Emerson's AFA series thermostatic ex-pansion valve is designed for air condi-tioning and commercial refrigerationapplications. The AFA is ideal for thoseapplications requiring compact size com-bined with stable and accurate controlover wide load and evaporator tempera-ture ranges.

R-12 Internal EqualizedNo. Emerson Refg Ton Inlet Outlet Each200344A AFA 1/4 FC R-12 1/4 1/4 sae 3/8 sae $101.94200321A AFA 1/2 FC R-12 1/2 1/4 sae 3/8 sae $101.94200322A AFA 1 FC R-12 1 3/8 sae 3/8 sae $101.94

Automatic Expansion ValvesAutomatic expansion valves are devel-oped for small cooling units where theheat load is reasonably constant. Valvecan be used as a small capacity hotgas by-pass valve. The ACP seriesvalve is ideal for room air conditioners,domestic refrigerators, drink dis-pensers, food dispensers, ice creamcabinets, bottle coolers, home freezers,ice cube makers, ice cream freezersand milk coolers.

Valve is adjustable from 0 to 80 psig.

Tons @ Pressure DropAcross Valve

R134A R407C R404A,R507R-12 R-22 R-502

No. Emerson 60 psi 100 psi 100 psi Inlet Outlet Each200335A ACP 3 .65 .91 .61 1/4 sae 3/8 sae $120.76200336A* ACP B 3 .54 .91 .61 1/4 sae 3/8 sae $120.76

* ACP B 3 has an internal bleed for applications with a small low torquecompressor motors.

HFESC

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 28: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

115HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

CAP TUBE | DRIERS | TXV

Copper Capillary Tubing

This soft copper capillary tubing is precision plugdrawn and has been thoroughly dehydrated,sealed and individually packaged. Available in fivesizes to cover hundreds of applications.

See chart below.

ModelBC 5BC 1BC 2BC 3BC 4

I.D..028.031.040.052.064

Each$15.62$19.94$19.98$20.66$23.42

Spun Copper Liquid Line Filter Drier

Copper tubing of the highestquality and strength. 100%molecular sieve for high ca-pacity of water rentention.

For use with 134a,blends and systems with con-ventional refrigerants. Rec-ommended for use in originalequipment or replacementresidential,air conditioning or refrigera-tion equipment.

EmersonCU-80

CU-619CU-620CU-200

DescriptionStandard DrierAccess ValveAccess Valve

Stepped Fittings

Each$8.36

$16.44$20.50$13.66

No.68064680666049968065

Danfoss Expansion Valves

Broad temperature range -40 to 50 degrees.Applicable for deep freezing, refrigerationand air conditioning. Interchangeable orificeassembly for easier stocking, capacity match-ing and service.

3/8 sae inlet x 1/2 sae outlet

Oil Separators

The 500 series are impingement screen type oilseparators. They work by having the compressedmass flow enter into a larger separator chamberwhich lowers the velocity and then the atomizedoil droplets collect on the impingement screen sur-face. As the oil droplets agglomerate into largerparticles they fall to the bottom of the separator oilreservoir. The 500 series allows accessibility. Re-placement parts can be ordered.

RefrigR 12R 12R 22R 22R 502R 502

TypeTF2

TFE2TX2

TEX2TY2

TEY2

EqualIntExtIntExtIntExt

Each$109.54$134.94$109.54$143.04$109.54$143.04

No.681016810268103681046810568106

Inlet1/4"1/4"5/16"

5/16" ,3/8"

Outlet1/4"CapCap

5/16" ,3/8"

OuterDiameter

3/4"3/4"1"1"

No.68064680666049968065

DescriptionCutterGauge

Each$18.36$46.16

Capillary Tube Accessories

This reference chart capillary tube lengths are av-erage measurements for average conditions.Lengths may have to be adjusted for exact re-placements.

HP Ref Low Med High1/8 12 108" #5 84" #5 48" #5

134a 118" #5 96" #5 58" #51/6 12 120" #1 96" #1 72" #1

134a 132" #1 110" #1 86" #11/5 12 54" #1 36" #1 24" #1

134a 60" #1 41" #1 29" #122 65" #1 43" #1 29" #1

1/4 12 43" #1 90" #2 60" #2134a 47" #1 103" #2 72" #222 52" #1 108" #2 72" #2

1/3 12 93" #2 72" #2 36" #2134a 102" #2 83" #2 43" #222 112" #2 86" #2 43" #2502 122" #2 95" #2 48" #2

1/2 12 96" #3 48" #3 90" #4134a 105" #3 55" #3 108" #422 115" #3 58" #3 108" #4502 127" #3 63" #3 119" #4

3/4 12 60" #3 92" #4 72" #4134a 66" #3 106" #4 86" #422 72" #3 110" #4 86" #4

502 79" #3 121" #4 94" #41 12 132" #4 84" #4 54" #4

134a 144" #4 96" #4 65" #422 48" #3 101" #4 65" #4502 53" #3 119" #4 71" #4

Connections

R134a1/31/33/43/4

R221/21/211

DescriptionStandard DrierAccess ValveAccess Valve

Stepped Fittings

No.68064680666049968065

Recommended Tonnage

Orifice00010203040506

R121/51/41/21

1-1/223

R221/31/21

1-1/22-1/2

35

R5021/51/41/21

1-1/223

Each$13.14$22.30$13.52$13.52$13.52$13.14$13.52

No.68110681116811268113681146811568116

Orifices for Danfoss TXV

Temprite900501502503504506

Line3/81/25/87/8

1-1/81-5/8

R134A2.121.833.665.497.3213

R404A3.2521.85.68.411.223.6

Each$319.24$323.08$330.78$361.54$365.40$688.48

$6.16

No.29328293212932229323293242932628515

Tons at +40 EvapTemperature

Header Gasket for 29321-26

Capillary Tube 10 ft. Lengths

LengthIn Inches

7-3/8"8-7/8"9-1/2"

10-1/2"

Block Style Liquid Line Drier

Economy solid core liquid line filter drier idealfor use with CFC and HCFC refrigerants.

No. Alco Each200203A ADK-32SVCAP $27.78

ConnectionsInlet Outlet1/4" Cap Out

No.0820661709

No.0820008201082020820308204

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 29: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

116 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

The Factory Authorized Parts DifferenceFilter-DriersFactory Authorized Parts Training GuideFactory Authorized Parts are designed to meet exact Carrier® Corporation specifications, ensuring optimum system performance, proven reliability, easy installation and maintenance and safe system operation.

Sales Centers

F.A.P. Filter-Drier(built for Puron® applications)

100% Molecular Sieve (XH-11) keeps refrig-erant at low water concentrations and helpsprevents freeze-up, rust and acid formation.

The molecular size - XH11 - provides enoughcapacity to absorb all the initial water andwater that migrates over time, but does notco-absorb refrigerant or oils. It also allows forminimal lubricant additive depletion.

Added filter cylinder and exclusive design of flipped filter, baffle plate and 100 meshscreen provide maximum filtration andgreater contaminant catching capacity thancore type driers.

F.A.P. Drier is compatible with Puron refrigerant(minimal absorption and reaction with the R-32 component of Puron refrigerant);Minimizes lubricant breakdown into acids.

Filter design helps avoid hydrolysis of refrigerant and formation of acids, whichhelps product to meet stringent reliability requirements. Must be capable of withstand-ing 500 hours salt spray test per Carrier Engineering Requirement R-203.

Solid copper thin wall extended fittings. The desiccant mechanical property must remain constant (no erosion) for a minimumapplication life of 15 years.

Aftermarket Filter-Drier(built for R-410A applications)

Varying mix of dessicants, often 75% Molecular Sieve and 25% Activated Alumina.

The sizes of aftermarket filter-drier's molecular sieve often do not have enough water capacity and may not solve co-absorption issue.

Generic design of aftermarket filter-drier internal components often does not maximize dirt filtration capability.

R-410A aftermarket filter driers often havetoo little drying agent resulting in much lesswater removing capacity.

Decreased molecular sieve of some aftermarket filter-driers may cause freeze-ups in the capillary tube or expansion valve. Also, hydrolysis of the refrigerant can occur, forming corrosive acids.

Aftermarket driers often have non-extendedconnections which may lead to the damageof internal filter-drier components during soldering/brazing. Some aftermarket driersuse copper plated connections vs solid copper design.

FeaturesDessicant Mix (% of molecular sieve vsactivated alumina)

Molecular size ofdessicant sieve

Dirt filtration capability (dirt, copper/iron oxides, scale, flux, metal chips)

Water capacity

Corrosion resistanceability

Construction

SystemPerformance

SystemReliability

Replacement Components Division • © Carrier Corporation 2011 Printed in the U.S.A. • Edition Date: 04/2011For promotional information visit www.totaline.com and for technical information visit www.hvacpartners.com Lit. No.: 570-940

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 30: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

117HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

FAP DRIERS / MOISTURE LIQUID INDICATORS

Factory Authorized Driers

Puron R410A

Liquid Line Driers

No. Size Cu In. Used On

KH43LG073 3/8" OD 8 cu in. A/C

KH43LG074 3/8" OD 16 cu in A/C

KH43LG075 3/8" OD 30 cu in A/C

KH43LG072 3/8" OD 6.5 cu in. HP

Suction Line Driers

No. Size Cu In. Used On

KH45LG140 3/4" OD 8 cu in. A/C or HPKH45LG141 7/8" OD 15 cu in A/C or HP

Totaline Driers

Liquid Line Driers

No. Size Cu In. Used On

P502C083S 3/8" OD 8 cu in. A/C

P502C163S 3/8" OD 16 cu in A/C

Suction Line Driers

No. Size Cu In. Used On

P503C166S 3/4" OD 16 cu in. A/C

P503C167S 7/8" OD 16 cu in A/CP503C309S 1-1/8" OD 30 cu in A/C

Moisture Liquid Indicators

AMI Moisture Liquid Indicators

ALM Liquid Moisture Indicators

Extended Ends Sweat x Sweat

hcaE.oNoclA.oN

82.24$2TT1-IMAA718002

82.24$3TT1-IMAA818002

24.12$3TT1-MLAA138002

81.44$4TT1-IMAA918002

01.05$5TT1-IMAA028002

27.37$7TT1-IMAA128002

83.67$9TT1-IMAA228002

Male Flare x Female Flare

hcaE.oNoclA.oN

41.03$2MF1-IMAA008002

41.03$3MF1-IMAA108002

85.73$4MF1-IMAA208002

Bushing

hcaE.oNoclA.oN

05.54$11S2-IMAA328002

80.35$31S2-IMAA428002200825A AMI-2S17 $65.60

4 and 5 Tons

Description

1.5 to 3 Tons3.5 to 5 Tons

Description

1.5 to 5 Tons - Bi-Flow

1.5 to 2.5 Tons

1.5 to 5 Tons

Connection Line Size

Connection Line Size

1.5 to 3 Tons

3.5 to 5 Tons3.5 to 5 Tons

Description

1.5 to 5 Tons

1.5 to 5 Tons

Description

5/8 OD (fem.) x 5/8 OD (fem.)

1 3/8 ODM Bushing

1 5/8 ODM Bushing

2 1/8 ODM Bushing

Connection Line Size

3/8 male flare x 3/8 female flare

1/2 male flare x 1/2 female flare

7/8 OD (fem.) x 7/8 OD (fem.)

1 1/8 OD (fem.) x 1 1/8 OD (fem.)

1/4 male flare x 1/4 female flare

Premium moisture indicator with 3% high accuracy moisture indicator for CFC, HCFC and HFC refrigerants including R-410A. Replaceable lens assembly and oring.

Economical hermetic moisture indicator utilizes a 10% relative humidity indicator for CFC, HCFC, and HFC refrigerants.

1/4 OD (fem.) x 1/4 OD (fem.)

3/8 OD (fem.) x 3/8 OD (fem.)

3/8 OD (fem.) x 3/8 OD (fem.)

1/2 OD (fem.) x 1/2 OD (fem.)R

efri

ger

atio

nR

efri

ger

atio

n

Page 31: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

118 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

ALCO Liquid Line Driers

ALCO Extra-Klean filter driers are specifically designed toprotect the refrigerant system from liquid and solid contaminants.They incorporate a desiccant specially formulated and blended formaximum moisture and include advanced materials to removeacid and prevent wax build-up.

EK driers can be used on CFC, HCFC, and HFC refrigerant systems.

Nominal System TonnageConn. Size Overall Refrigeration, Low Temp & Commercial Air Conditioning

Part No. Emerson EK Type Length Installations Field Replacement & Installations EachR-12 / R-134A R-22 / R-410A R-404 R-12 / R-134A R-22 / R-410A

200000A 032 1/4 sae 4 3/8 1/2 1/21/2 1 1 1/2

$16.98200100A 032S 1/4 OD 3 7/8 $16.98

200001A 052 1/4 sae 4 13/16 3/4 3/4 $21.28200101A 052S 1/4 OD 4 7/16 $21.28

200002A 053 3/8 sae 5 1/81 1/2 2 1 1/2 3 4

$21.28200102A 053S 3/8 OD 4 1/2 $23.22

200003A 082 1/4 sae 5 5/81 1 3/4 1 1/2 2

$29.36200103A 082S 1/4 OD 5 1/4 $29.36

200004A 083 3/8 sae 5 15/162

32

4 5 $26.52200104A 083S 3/8 OD 5 5/16 $26.52

200005A 084 1/2 sae 6 3/16 4 5 7 1/2 $27.70200105A 084S 1/2 OD 5 3/8 $27.70

200006A 162 1/4 sae 6 9/161 1/2 2 1 1 1/2 2

$33.86200106A 162S 1/4 OD 6 3/16 $33.86

200007A 163 3/8 sae 6 7/85

4 5$33.96

200107A 163S 3/8 OD 6 1/4 $35.36

200008A 164 1/2 sae 7 1/16 3 35 10

$36.44200108A 164S 1/2 OD 6 5/16 $36.36

200009A 165 5/8 sae 7 1/27 1/2 7 1/2 12

$38.52200109A 165S 5/8 OD 6 9/16 $38.44

200010A 303 3/8 sae 9 5/84

5 34 6

$61.20200110A 303S 3/8 OD 9 $61.20

200011A 304 1/2 sae 9 7/87 1/2 4 7 1/2 10

$61.20200111A 304S 1/2 OD 9 1/8 $61.20

200012A 305 5/8 sae 10 5/167 1/2 10 5

10 15$61.20

200112A 305S 5/8 OD 9 5/16 $61.20

200113A 307S 7/8 OD 9 7/8 18 24 $66.90

200013A 413 3/8 sae 9 3/4 4 5 5 $87.16

200014A 414 1/2 sae 105 7 1/2 12

$87.16200114A 414S 1/2 OD 9 1/4 $87.16

200015A 415 5/8 sae 10 7/167 1/2 7 1/2

7 1/212 18

$87.16200115A 415S 5/8 sae 9 7/16 $87.16

200117A 417S 7/8 OD 1010

10 18 25 $87.16

200119A 419S 1 1/8 OD 10 5/16 12 10 20 27 $94.46

200120A 757S 7/8 OD 15 7/16 20 25 15 22 30 $126.76

200121A 759S 1 1/8 OD 15 3/4 22 30 20 25 34 $145.04

EMERSON LIQUID LINE DRIERS

Emerson Liquid Line Driers

Emerson Extra-Klean filter driers are specifically designed toprotect the refrigerant system from liquid and solid contaminants.They incorporate a desiccant specially formulated and blended formaximum moisture and include advanced materials to removeacid and prevent wax build-up.

EK driers can be used on CFC, HCFC, and HFC refrigerant systems.

Recovery Machine Drier200016A EK032MF 1/4" FE SAE X 1/4" MALE SAE $17.06

4 5

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 32: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

119HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

EMERSON SUCTION LINE | HEAT PUMP DRIERS

Heat Pump Driers

Emerson's bi-directional filter-drier provides heat pump system protection in heating and coolingcycles summer and winter with one compact unit. Provides effective removal of moisture, acidand solid contaminants. Internal check valves allow flow and filtration in either direction.

Conn. Flow CapacitySize Overall TONS @ 1 PSI

Part No. Emerson BFK Type Length R-22 / R410A Each200941A 083 3/8 sae 6 1/8 4.5 $53.20200940A 083S 3/8 OD 5 7/16 5.1 $53.20200942A 084 1/2 sae 6 1/4 6.4 $54.22200943A 084S 1/2 OD 5 1/2 6.7 $54.22200945A 085S 5/8 OD 5 5/8 8.1 $55.46200951A 163 3/8 sae 6 3/4 4.6 $78.18200950A 163S 3/8 OD 6 1/8 5.2 $78.18200952A 164 1/2 sae 6 15/16 7.7 $79.44200953A 164S 1/2 OD 6 3/16 8.1 $79.44200954A 165 5/8 sae 7 7/16 8.3 $81.32200955A 165S 5/8 OD 6 3/8 8.7 $81.32

Emerson Suction Line Driers

Emerson's ASD and SFD Suction line filter-driers incorporate the protective filter plus a desiccant spe-cially blended for maximum moisture and acid removal. Compressor manufacturers recommend theinstallation of suction line filter driers to protect their equipment from contaminants left in the systemafter a burnout. Emerson driers feature filtration to less than 10 microns. ASD and SFD models arespecially suited for system clean-up after a burnout or when major work has been performed.

ASD Suction Driers Flow Capacity in Tons as listed conditionsR-12 / R-134A R-502 R-404A / R-507 R-22 R-410A

Evaporator Temperature degrees F40 20 0 -20 40 20 0 -20 40 20 0 -20 40 20 0 -20 40 20 0 -20

Conn. Overall Pressure Drop (PSI)No. Emerson ASD Size Length 3 2 1.5 1 3 2 1.5 1 3 2 1.5 1 3 2 1.5 1 3 2 1.5 1 EachKH45LD010 ASD28F3 3/8 sae 1.1 0.62 0.51 0.39 2.1 1.1 0.68 0.45 - - - - 2.3 1.3 0.87 0.64 - - - - $135.54200150A ASD28S3-VV 3/8 OD 5 19/32 1.1 0.6 0.5 0.5 2.2 1.1 0.7 0.5 2.1 1.1 0.7 0.5 2.3 1.3 0.9 0.6 1.6 0.9 0.6 0.4 $76.72

200151A ASD28S4-VV 1/2 OD 5 11/16 1.8 1.2 0.8 0.7 3.7 1.8 1.1 0.7 3.6 1.8 1.1 0.7 3.8 2.1 1.4 1 2.6 1.4 1.0 0.7 $76.72

200160A ASD35F5-VV 5/8 sae 7 9/16 2.1 1.4 1.1 0.9 4.2 2.1 1.3 0.9 4.1 2.1 1.3 0.9 4.4 2.5 1.7 1.2 3.0 1.7 1.2 0.8 $97.80200152A ASD35S5-VV 5/8 OD 6 17/32 2.8 1.9 1.4 1.1 5.6 2.8 1.7 1.1 5.4 2.8 1.7 1.1 5.8 3.2 2.2 1.6 4.0 2.2 1.5 1.1 $94.88

200153A ASD45S6-VV 3/4 OD 7 3/4 3.8 2.5 1.8 1.2 6.6 3.7 2.5 1.5 6.4 3.7 2.5 1.6 7 4.6 3.2 2 4.8 3.2 2.2 1.3 $108.52

200154A ASD45S7-VV 7/8 OD 7 15/16 5.0 3.6 2.3 1.5 7.7 4.8 3.3 1.9 7.5 4.8 3.3 2 9.2 6 4.1 2.6 6.3 4.1 2.8 1.7 $108.52

200155A ASD50S9-VV 1 1/8 OD 8 27/32 7.1 5.0 3.2 1.8 11 6.9 4.6 2.7 11 6.9 4.6 2.8 13.2 8.5 5.7 3.5 9.0 5.8 3.9 2.3 $130.00

200156A ASD75S11-VV 1 3/8 OD 12 1/4 8.6 5.9 3.7 2.0 14 8.4 5.4 3.1 14 8.4 5.4 3.2 16.2 10.2 6.7 4 11 7.0 4.6 2.7 $179.92

200157A ASD75S13-VV 1 5/8 OD 12 5/32 9.0 6.2 3.9 2.1 15 8.9 5.7 3.3 15 8.9 5.7 3.4 17.3 10.7 7 4.2 12 7.3 4.8 2.8 $179.92

SFD Suction Driers Flow Capacity in Tons as listed conditionsR-12 / R-134A R-502 R-404A / R-507 R-22 R-410A

Evaporator Temperature degrees F40 20 0 -20 40 20 0 -20 40 20 0 -20 40 20 0 -20 40 20 0 -20

Conn. Overall Pressure Drop (PSI)

No. Emerson SFD Size Length 3 2 1.5 1 3 2 1.5 1 3 2 1.5 1 3 2 1.5 1 3 2 1.5 1 Each200899A SFD13S3 3/8 sae 4 27/32 0.7 0.4 0.2 0.1 1.3 0.7 0.4 0.2 1.7 0.7 0.4 0.2 1.4 0.8 0.4 0.2 1.0 0.5 0.3 0.1 $58.00200900A SFD13F3 3/8 OD 5 1/2 1.3 0.8 0.5 0.2 2.0 1.1 0.7 0.4 1.9 1.1 0.7 0.4 2.2 1.3 0.8 0.5 1.5 0.9 0.5 0.3 $64.48

200901A SFD13S4 1/2 OD 4 15/16 2.2 1.5 1.1 0.6 3.1 1.9 1.3 0.8 3 1.9 1.3 0.8 3.5 2.3 1.6 1 2.4 1.6 1.1 0.7 $63.42

200902A SFD27S7 7/8 OD 7 1/2 4.6 3.2 2.0 1.1 6.7 4.1 2.7 1.5 6.5 4.1 2.7 1.6 7.5 4.8 3.2 2 5.1 3.3 2.2 1.3 $94.36

200903A SFD27S9 1 1/8 OD 7 5/8 5.1 3.5 2.1 1.1 7.7 4.6 3.0 1.6 7.5 4.6 3 1.7 8.5 5.4 3.5 2.1 5.8 3.7 2.4 1.4 $100.84

200904A SFD54S11 1 3/8 OD 12 1/4 4.4 2.9 1.8 1.0 6.6 3.9 2.5 1.4 6.4 3.9 2.5 1.5 7.3 4.6 3 1.8 5.0 3.2 2.0 1.2 $153.22

200905A SFD54S13 1 5/8 OD 12 5/32 4.5 3.1 1.9 1.0 6.7 4.0 2.6 1.5 6.5 4 2.6 1.6 7.4 4.7 3.2 2 5.1 3.2 2.2 1.3 $153.66

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 33: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

120 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

SUCTION | SHELL DRIERS

STAS and ADKS Shell DriersPart No. Emerson No. Core Size Conn. Refrigeration, Low Temp Air Conditioning

Size Qty OD & Commercial Installations Field Replacement & InstallationsR-12 / R-134A R-22 R-404 / R-410A R-12 / R-134A R-22 Price

200185A STAS-485T 48 1 5/8 8 10 8 8 10 $319.50200186A STAS-487T 48 1 7/8 10 13 10 10 12 1/2 $319.50200923A STAS-489T 48 1 1 1/8 10 15 10 10 15 $336.84

200187A STAS-967T 48 2 7/8 20 25 15 20 25 $371.84200188A STAS-969T 48 2 1 1/8 25 30 20 25 30 $371.84200924A STAS-9911 48 2 1 3/8 30 35 25 30 35 $421.10

200189A STAS-19211T 48 4 1 3/8 50 70 45 50 70 $546.84200190A STAS-19213T 48 4 1 5/8 60 80 55 60 80 $546.90

200191A ADKS-30013T 100 3 1 5/8 50 65 45 50 65 $1,232.74

200192A ADKS-40021T 100 4 2 5/8 75 100 60 75 100 $1,349.50

Shell Liquid and Suction Line Driers

Replaceable core filter drier for CFC, HCFC, HFC refrigerants for the usein large commercial air conditioning and refrigeration systems.

Features: Full flow fittings for low pressure drop, corrosion resistantepoxy powder paint finish, sturdy steel shells for long life durability, solidcopper fittings.

Filter Cores and Blocks

The F-48 and F-100 filter core are a pleated felt core with filtration capabilities to 10 mi-crons and have optimum surface area designed for suction line service to control solidcontaminants and prevent their entry into the compressor.

The D-48 standard capacity block provides system protection from water and acids inthe majority of general purpose applications.

The H-48 and H-100 are similar to the standard block except with much greater watercapacities for critical applications or where system conditions indicate the presence ofan abnormal amount of water.

The W-48 and W-100 are a filter drier block possessing water capacities comparable tothe standard block and also featuring activated carbon for rapid system clean-up fol-lowing a motor burnout, also provides wax and resin control

Part No. Emerson No. Core Size Description DimensionsA B C Each

200198A F-48 48 Felt Filter Core 5 1/2 2 13/16 3 3/4 $39.16200193A D-48 48 Standard Capacity 5 1/2 1 49/64 3 23/32 $35.40200194A H-48 48 High Capacity 5 1/2 1 49/64 3 23/32 $49.04200195A W-48 48 Burnout Block 5 1/2 1 49/64 3 23/32 $52.58

200200A F-100 100 Felt Filter Core 6 1/2 3 3/4 4 13/16 $86.76200196A H-100 100 High Capacity 6 1/2 2 1/6 4 13/16 $101.38200197A W-100 100 Burnout Block 6 1/2 2 1/6 4 13/16 $122.00

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 34: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

121HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

SOLENOID VALVES / COILS

evlaVdioneloSevlaVdioneloSAR042BR001

hcaEeziStroP.oN03.36$"61/1A10500260.36$"61/1A00700203.36$"61/1A205002

hcaEeziStroP.oN23.561$"2/1A41500206.152$"61/9A51500206.152$"61/9A30700284.253$"4/3A407002A10500284.253$"4/3A507002A00700228.105$"1A615002A205002

21.988$"4/1-1A607002Solenoid Valve200RB

200514A 12.2 14.8 15.6 14.8 10.3 10.1200515A200703A200704A200705A200516A 37.3 55.1 58 55.2 38.3 37.3200706A 58.8 86.8 95.4 90.8 65.7 62

Solenoid Coils

hcaEeziStroP.oN03.36$"8/1A10700282.67$"61/3A20700264.801$"4/1A60500264.801$"4/1A40500264.801$"4/1A505002 Each

02.06$43.821$"61/508A500202.06$43.821$"61/5A70500241.77$43.821$"61/5A90500202.06$43.821$"8/3A21500241.77$43.821$"8/3A01500263.77$43.821$"8/3A115002

200701A 2.3 2.7 3.6 3.4 1.9 1.9200702A 3 3.6 4.8 4.5 2.5 2.6200506A200504A200505A200508A200507A200509A200512A200510A200511A

200547A X-22164 120200539A AMG 480

200538A AMG 120 / 240200535A AMG 208 / 240

200537A AMG 120

21

200536A AMG 24No. Emerson No. Voltage

27.6 33.2 34.9 33.2 23 22.7

24 28.9 30.5 29

240RA20T13M

19.8

240RA8T5M240RA9T7M

240RA12T9M240RA16T11M

5/8" OD7/8" OD

1-1/8" OD

R-22 R-407CR-404 /

507 R-502

240RA9T9M240RA12T7M 7/8" OD

1-1/8" OD1-3/8" OD

1-5/8" OD

9.5 8.9 5 5.1

Emerson No. Conn. Size

Nominal Liquid Capacities (tons)

No. R-12 R-134A

8 7.5 4.2 4.2

8.2 7.7 4.3 4.5

5/8" OD1/2" SAE1/2" OD5/8" OD

6

5.2

5 6

6.2

7.2

200RB6F4200RB6T4200RB6T5

3/8" OD3/8" OD3/8" SAE3/8" OD1/2" OD1/2 SAE1/2" OD

200RB4F3200RB4T3200RB4T4200RB5F4200RB5T4200RB5T5

1/4" OD 3/8" OD1/4" SAE

Nominal Liquid Capacities (tons)

200RB2T3200RB3T3

0.85 0.83

Conn. Size

R-404 /R-507No.

100RB2S2100RB2S3100RB2F2

R-12 R-134A R-22 R-407C

Emerson No. Conn. Size

Emerson No.

R-502

1 1.2 1.27 1.21

Nominal Liquid Capacities (tons)

No. R-12 R-134A R-22 R-407CR-404 /R-507 R-502

R-

The 100RB is a direct-acting, 2-way, normally closed valve. The 100RB valves are used for liquid or discharge gas refrigerant service.

Features- 1 coil fits all valves- Extended ends- Max. fluid temp. 250 deg- Max. working pressure 500 psig- MOPD 300 psig

The 200RB is pilot-operated, 2-way normally closed valve. The 200RB valves are used for liquid, discharge, or suction gas refrigerant service.

Features- 1 coil fits all valves- Extended ends- Max. fluid temp. 250 deg- Max. working pressure 500 psig- Min. operating pressure drop 2 psi- MOPD 300 psig

The 240RA is a 2-way, normally closed diaphragm valve. The 240RA valves are used with liquid, suction, and hot gas service.

Features- 1 coil fits all valves- Can be brazed into the line without disassembly

- PTFE diaphragm for high temperature applications

- Extended ends- Max. fluid temp. 250 deg- Max. working pressure 500 psig- MOPD 300 psig

Solenoid Valve Parts

Part No. Emerson Description Models used on Each200668A KS-30116 Repair Kit 200RB -200670A KS-30061 Repair Kit 240RA 8 $103.34200671A KS-30062 Repair Kit 240RA 9 $116.82200672A KS-30063 Repair Kit 240RA 12 $105.02200673A KS-30065 Repair Kit 240RA 16 $110.78200674A KS-30097 Repair Kit 240RA 20 $180.50

200513A LS-30117 Manual Stem 200RB $80.40200675A KS-30014 Coil Retainer $19.02200692A X11981-1 Spanner Wrench $8.96

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 35: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

122 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

REGULATORS | HEAD PRESSURE CONTROL

HEAD PRESSURE CONTROL IPR Upstream Pressure RegulatorInlet Pressure Regulator (Evaporator Regulator)

Features:• A direct acting EPR(V) designed maintains a

predetermined minimum evaporator pressureregardless of load or suction line changes.

• Operates from an inlet pressure signal, opening ona rise in pressure above the valve set point andclosing at any inlet pressure below the set point.

• Supplied with a pressure tap in the inlet connectionas standard.

• Available with an option of adjustment ranges of0-50 PSIG, 30-100 PSIG or 65-225 PSIG.

• Supplied with strainer in the inlet connection as standard.

• Supplied with copper line connections allowing installation with phos copper.

• Safe working pressure of 400 PSIG.

• May be installed in either a horizontal or a vertical refrigeration line.

• Compact design permits minimal space requirements.

• UL listed under file No. SA5312.

No. Emerson SIZE PSIG EACH200558A IPR-6 1/2 SAE 0-50 $264.28200556A IPR-6 7/8 OD 0-50 $264.28

OPR Downstream Pressure Regulators

Outlet Pressure Regulator (Crankcase Regulator)

• A direct acting crankcase pressure regulator designedto prevent overloading of the compressor motor.

• Limits crankcase pressure to a maximumpredetermined pressure.

• Supplied with a pressure tap in the inletconnections standard.

• Supplied with copper line connections allowinginstallation with phos copper.

• SWP 400 PSIG

• May be installed in either a horizontal or a vertical refrigeration line.

• Compact design requires minimal space.

• Supplied with a strainer in the inlet connection as standard.

• Available with an option of adjustment ranges of 0-60 PSIG, 50-130 PSIG,or 100-225 PSIG.

No. Emerson SIZE PSIG EACH200650A OPR-6 5/8 OD 0-60 $229.70

200652A OPR-10 7/8 0-60 $319.28

200654A OPR-10 1/8 OD 0-60 $319.28

200655A OPR-10 1-3/8 OD 0-60 $319.28

General:This application of air cooled condensers for year round operation or duringperiods of low ambient temperatures requires some means of control to main-tain adequate condensing pressures to ensure proper system operation.

It is essential that proper liquid refrigerating pressure to be controlled to:

1. Maintain liquid subcooling and prevent liquid line flash gas.

2. Provide adequate pressure at the inlet side of the Thermo valve to obtainsufficient pressure drop across the valve ports.

3. Properly operate systems without gas defrost or hot gas bypass.

4. Provide adequate pressure for operation of heat reclaim systems.

Without proper control of condensing pressure, serious consequences in theway of poor refrigeration and component damage can occur. The Alco HeadMaster control offers an efficient and economical approach to this commonindustry problem on air-cooled condensers.

The Head Master 3 way head pressure control valve eliminates the need forspecial piping or multiple control valves. As a single unit it simplifies piping andreduces the installation costs.

No. Emerson O.D. REFRIG. EACH200669A HP5T3-B 3/8 R22 $256.08

200662A HP8T7-B 7/8 R22 $268.12

NOMINAL CAPACITY (TONS)PRESSURE DROP-PSI

ALCO REFRIG. 1 2 3 4 5HP-5 R-12 1.7 2.4 3.0 3.4 3.8HP-8 R-12 4.7 6.5 8.0 9.2 10.3HP-5 R-22 2.2 3.2 3.9 4.5 5.0HP-8 R-22 6.0 8.5 10.5 12.0 13.5HP-5 R-502 1.5 2.1 2.6 3.0 3.3HP-8 R-502 3.9 5.5 6.7 7.8 8.7

Developed specifically to maintain proper air cooled condenser pressuresduring periods of low outdoor ambient conditions.

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 36: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

123HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

REPLACEMENT COILS

The Factory Authorized Parts DifferenceReplacement CoilsFactory Authorized Parts Training GuideFactory Authorized Parts are designed to meet exact Carrier® Corporation specifications, ensuring optimum system performance, proven reliability, easy installation and maintenance and safe system operation.

F.A.P. Coils are manufactured to the same specifications asthe OEM coils. They are built to current product designs andenhancements for optimum system performance.

F.A.P. Coils are built with the same coil surfaces as the factory for exact performance. Standard evaporator andcondenser coils have copper or aluminum plate fins mechanically bonded to internally grooved tubes for maximumheat transfer capability. F.A.P. coils are also tested to complywith UL fatigue and burst strength requirements.

Since our F.A.P. coils are consistent in design andperformance with OEM coils, the system performance ensured through the AHRI certification program is maintained.

F.A.P. Coils are made of quality materials and manufacturedto Carrier's rigid quality standards to maintain their durabilityand integrity under design operating conditions.

F.A.P. Coils undergo stringent quality testing, including leak tests at 150 psig (1034 kPA) and pressure tests at 450 psig (3103 kPA). Testing requirements may vary byproduct and refrigerant.

Optional pre-coated, copper-fin and e-coated coils are available depending on the specific application. Coatings arecorrosion tested per Carrier procedures and criteria to ensureproper application selection. Optional e-coated aluminum-fincoils have a flexible epoxy polymer coating uniformly appliedto all coil surface areas without material bridging betweenfins. The e-coating process ensures complete coil encapsulation.

F.A.P. coils are backed by Carrier's Replacement Components warranty, which warrants each F.A.P. coil to befree from defects in material and workmanship for a periodof one year from date of shipment.

F.A.P. coils are UL listed and approved. Every F.A.P. coil is built to comply with internationally recognized safety standards, minimizing the risk of premature failure. UL also conducts ongoing, unannounced audits at the Carrier facility four times a year, ensuring the highest quality standards forour F.A.P. coils.

Aftermarket coil manufacturers do not have access toCarrier drawings and the latest product enhancements.

Aftermarket coil manufacturers do not have the fin diesthat were used in the original coil design and manufacture.These aftermarket manufacturers would be approximatingfactory fin and tube surfaces. This alternate coil surfacedesign may compromise the original equipmentperformance.

Aftermarket coil manufacturers do not participate in Carrier'sAHRI certification programs, therefore, their tube/fin designmay not meet Carrier's certified performance rating.

Aftermarket coil manufacturing quality standards vary bymanufacturer, possibly resulting in greater failure rates.

Aftermarket coil manufacturers leak and pressure test usingtheir own operating procedures. These procedures may notmeet the standards specified in the product UL file.

Aftermarket coil coating and corrosion test procedures andcriteria vary by aftermarket manufacturer, meaning heattransfer efficiency and performance cannot be guaranteed.Coating methods used by aftermarket manufacturers maybe inferior in durability and uniformity.

Many aftermarket manufacturers offer only limited productwarranties.

Aftermarket coils are not listed in the Carrier productUL file. The UL listing on the equipment is voided whenan aftermarket coil is installed.

Product Design

Fin and Tube Surfaces

AHRI System Performance

Quality Construction

Leak & Pressure Testing

Optional Coil Coatings

Carrier Warranty

UL Approved

SystemPerformance

SystemReliability

yt ef aS

Features F.A.P. Replacement Coils Aftermarket Coil Replacement

Sales CentersReplacement Components Division • © Carrier Corporation 2011 Printed in the U.S.A. • Edition Date: 04/2011For promotional information visit www.totaline.com and for technical information visit www.hvacpartners.com Lit. No.: 570-943

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 37: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

124 HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

HARRIS FILLER METAL SELECTION CHART

sudiuqiLsudiloSsredloS

01F°034F°034®etirB-yatS

8F°535F°0348etirB-yatS

6F°036F°064®tigdirBBridgit Water Soluble

Paste FluxAir-fuel

1178°F 1247°F 7 Flux Coated Air-fuel

1310°F 1475°F 5

1190°F 1500°F 3

1190°F 1465°F 3

1190°F 1425°F 5

1190°F 1480°F 3

01F°034F°034etirB-yatS

8F°535F°0348etirB-yatS

1145°F 1205°F 8

1250°F 1350°F 5

1225°F 1370°F 6.5

1195°F 1265°F 7

01F°034F°034etirB-yatS

8F°535F°0348etirB-yatS

1145°F 1205°F 8

1250°F 1350°F 5

1220°F 1435°F 4.5

1225°F 1370°F 6.5

1195°F 1265°F 7

1220°F 1305°F 7

1220°F 1305°F 7

deriuqeRxulFoNdetartoNF°428---roclA

* Aluminum dissimilar metal joints may subject to galvanic corrision

(1) Can be directly brazed or soldered

(2) Solder directly with Alsolder 500, or coat steel side with aluminum and solder with Alcor or Braze with Albraze 1070

** The higher the fluidity rating the faster the alloy flows within the melting range

NotRecommended

Safety-Silv40Ni2

Safety-Silv 45T

Not Rated

Stay-Clean®Soldering Flux

Safety-Silv® 56

Safety-Silv 40

Safety-Silv 45

Safety-Silv 45T

Copper or Brassto

Steel or Stainless

Stay-Silv WhiteBrazing Flux

Stay-Silv BlackFlux for Stainless

Oxy-acetylene(reducing flame)

Blockade

Stay-Clean Aluminum Soldering Flux

F°284F°193005redloslA

Copper or Brassto

Copper or Brass

Not Rated1080°F1070°FAl-braze 1070

1220°F 1435°F 4.5

Stay-Silv® 5

Air-fuel

Stay-SilvWhite Brazing Flux

Stay-Silv WhiteBrazing Flux

Stay-Silv BlackFlux for Stainless

Stay-Clean®Soldering Flux

No Flux required for copper-to-copper

joints with the phosphorus-bearing

filler metals. Forbrass and other

alloys of copper, use Stay-Silv WhiteBrazing Flux.

Stay-Clean®Soldering Flux

Air-fuel

Oxy-acetylene(neutral flame)

Air-fuel

Oxy-acetylene(slightly

reducing flame)

Safety-Silv 45

Metals to be JoinedMelting Range Fluidity

Rating**Fluxes

Torches & Flames***

Filler Metals

Brazing Filler Metals

Harris 0

Stay-Silv 15

Aluminum to Aluminum (1)

Aluminum toSteel or Stainless (2)*

Aluminum toCopper or Brass (2)*

Dynaflow®

Stay-Silv 6

Safety-Silv® 56

Safety-Silv 40

Air-fuel

*** For best results and strong leak proof bonds, filler metals should be applied to the joint area only after the parts are heated to the proper brazing or soldering temperatures.

Safety-Silv 40Ni2

Steel or Stainlessto

Steel or Stainless

Safety-Silv 50N

Safety-Silv 50N

Steel or Stainlessto

Carbides

Air-fuel

Air-fuelAl-braze 1070 Flux

Ref

rig

erat

ion

Ref

rig

erat

ion

Page 38: TECUMSEH CONDENSING UNITS - Harry Alterharryalter.com/Catalog/HA Catalog - Refrigeration.pdfTECUMSEH CONDENSING UNITS. HARRY ALTER CO. • Your one dependable source for everything

125HARRY ALTER CO. • Your one dependable source for everything in air conditioning, refrigeration, heating parts, supplies and equipment

SOLDER | FLUX

Silicone Brazing Allow Blockade

Flux-coated BLOCKADE brazes copper to brassand brass to brass. Brazes are very strong andductile. Should extra flux be needed, use whiteor black silver brazing flux.

No. Qty Each03147 20 sticks $44.38

Safety Silv 15 and Safety Silv 5

The original alloys used for brazing copper, brass,and bronze to each other or to themselves.

FlatNo. Silver Size Wt. Each03283 15% .05 x 1/8" 1 lb. $299.1803282 15% .05 x 1/8" 1/4 lb. $120.16

Dynaflow Brazing Alloy

Contains 6% silver, 6% phosphorus, and88% copper.

No. Weight Each03220 1/4 lb. $59.1003221 1 lb. $169.04

Safety Silv 56 andSafety Silv 35

Copper, brass, stainlesssolder to themselves oreach other.

Safety-Silv 35%

No. Diam. Weight Length Each03146 1/16" 5 oz. 330" $103.36

Safety-Silv 56%

No. Diam. Weight Length Each03274 1/16" 1 oz. 66" $102.8003249 1/16" 5 oz. 330" $125.40

Flux CoredAluminum Alloy

Use Alcor on heat ex-changers, air condi-tioners, aluminumalloy condensers, andaluminum to alu-minum alloy piping.

No. Diam. Weight Length Each02981 1/12" 1 oz 36" $48.08

Stay-Brite Silver Bearing SolderLow melting point andlow point of 400 deg Favoids copperannealing distortion andthe formation of oxideinside the tube. Usedwith Stay-Clean flux itwill solder copper, brass,and stainless steel to it-self or to each other. Used with Stay-Clean alu-minum flux it will solder aluminum to itselfor to material.

No. Diameter Wt. Each03060 1/8" 1 lb. $141.0603061 1/16" 1 lb. $122.92

Stay-Brite No. 8Silver Bearing SolderNo. Diameter Wt. Each03064 1/8" 1 lb. $164.48

Stay-Silv Brazing FluxFor use with solders and most braz-ing alloys for brazing stainless steel,iron, brass, and copper to them-selves or to each other. It should notbe used on aluminum. Chemicallyactive from 800 deg Fto 1700 deg F.

No. Description Each03047 7 oz. With Brush Cap $7.9403049 1 lb. Jar $11.90

Stay-Clean Soldering Flux

Used with Stay-Brite solder.It will solder copper, brass,stainless steel, or galvanized iron.Used for low temperature solders.

No. Description Each03055 4 oz. Paste $5.8803056 4 oz. Liquid $8.5003057 16 oz. Liquid $14.82

Stay-Silv Aluminum Soldering FluxUse Stay-Brite solder it will solder aluminum toaluminum or to copper, brass, stainless steel, orgalvanized steel.

No. Description Each03059 4 oz. Dispenser $13.48

Lead Free Bridget SolderLead free solder for joiningtight and loose fitting, waterpipe, silver bearing solderalso contains nickel resultingin high strength of a bridgetjoint far excess the pressurepoint at which copper tubing breaks.

No. Diameter Wt. Each03102 1/8" 1 lb. $58.56

95/5 Solid Wire SolderMelting Point 450 deg F (liquid)No. Diameter Wt. Each03100 1/8" 1 lb. $53.64

Brushes for Solder Flux

Handy brushes for applying solder flux to work.

No. Wide Length Pkg Each03152 3/8" 5" 10 $4.50

LA-CO Regular FluxNon-Acid Soldering Paste

Use regular flux with 40/60, 50/50,60/40, or 95/5 wire or bar solder,or any other standard soft solder,including lead free.

No. Weight Each29242 4 oz. $9.9229243 1 lb. $26.96

Low Heat Seal Stick

No. Description Each29217 Low Heat Seal Stick $38.42

LA-CO Fast Flux and Solder

Will solder copper, silver,terne plate, galvanizediron and other metals.

No. Description Each29219 Fast Flux and Solder $38.42

No. Sold only in lots of 12 Each03228 12-Lot—Each $2.56

A non-setting compound made of resins andfinely divided inorganic material that lubricatesand seals threaded joints. Withstands gasoline,oil, propane. Freon, water, steam, acid, brine,etc. Easily applied will not flow and clog smallsize pipe. Joints may be made and remade with-out cleaning. Nontoxic, excellent for food indus-try. For all types of metal or plastic threads.Approximate 1-1/2 oz. stick.

Pipetite-Stik

No. Description Each Stick29230 La-Co Slic-Tite Stick $20.12

Similar to the Slip-tite paste but made into a solidclean white stick saturated with Teflon and otherPTFE resins. In a tough plastic dispenser car-tridge ready for use. Has same properties anduses as the paste.

La-Co-Slic-Tite Stick

Ref

rig

erat

ion