  • Swing Type Hoistway Doors

    Technical Design SpecificationTechnical Design Specification

    Roped Hydraulic Residential Elevator

  • Roped Hydraulic Residential Elevator

    Canton Residential Spec

    Technical Specification

    3

    TABLE OF CONTENTS

    1. General ......................................................................................................................................5

    1.1. Description of Work ..................................................................................................................5

    1.2. Work to be performed by Others .............................................................................................5

    2. References ................................................................................................................................7

    2.1. American National Standards Institute (ANSI).........................................................................7

    2.2. American Society of Mechanical Engineers (ASME A17.1) ....................................................7

    2.3. National Electric Code (NFPA 70) ............................................................................................7

    3. Qualifications ...............................................................................................................................7

    3.1. A company with no less than (5) years of successful experience in the assembly and erection of similar type elevators and who has adequate product liability insurance shall perform the installation. ............................................................................................................7

    4. Regulatory Requirements ...........................................................................................................7

    4.1. The elevator installer shall verify requirements of the local authority having jurisdiction, obtain and pay for necessary municipal and state permits and inspections as required, and make tests as called for by the regulations of such authorities. ......................................7

    5. Submittals ....................................................................................................................................7

    5.1. Product Data .............................................................................................................................7

    5.2. Layout Drawings .......................................................................................................................7

    6. Product.........................................................................................................................................7

    6.1. Manufacturer.............................................................................................................................7

    6.2. Characteristics ..........................................................................................................................7

    7. Equipment ....................................................................................................................................8

    7.1. Operation ..................................................................................................................................8

    7.2. Hydraulic Power Unit ................................................................................................................8

    7.3. Plunger and Cylinder ................................................................................................................8

    7.4. Pipe Rupture Valve ...................................................................................................................8

    7.5. Car Frame Construction ...........................................................................................................9

    7.6. Platform Construction ...............................................................................................................9

    7.7. Suspension ...............................................................................................................................9

    7.8. Guide Rails ...............................................................................................................................9

    7.9. Electric Wiring ...........................................................................................................................9

    7.10. Controller ..................................................................................................................................9

    7.11. Home Park Feature ..................................................................................................................9

    7.12. Emergency Power Lowering and UPS Battery Backup ..........................................................9

  • Roped Hydraulic Residential Elevator

    4

    Technical Specification

    Canton Residential Spec

    7.13. Low Oil Control .......................................................................................................................10

    7.14. Operating Fixtures ..................................................................................................................10

    7.15. Door Interlocks .......................................................................................................................10

    7.16. Hoistway Doors ......................................................................................................................10

    7.17. Cab Enclosure ........................................................................................................................10

    7.18. Car Gate..................................................................................................................................11

    8. Execution ...................................................................................................................................12

    8.1. Examination ............................................................................................................................12

    8.2. Installation ...............................................................................................................................12

    8.3. Operating Instructions ............................................................................................................12

    8.4. Maintenance ...........................................................................................................................12

    8.5. Warranty ..................................................................................................................................12

  • Roped Hydraulic Residential Elevator

    Canton Residential Spec

    Technical Specification

    5

    1. GENERAL

    1.1. Description of Work

    1.1.1. These specifications are intended to cover the complete installation of one (1) CEI-750 or CEI-950 residential elevator. The elevator is to be installed in a first class workmanlike manner and is to include all work and materials in accordance with specifications and installation drawings. The elevator shall be guaranteed for two years against defective manufacturing. It shall be in compliance with the applicable sections of the Safety Code for Elevators and Escalators ASME A17.1 and all local codes having jurisdiction.

    1.2. Work to be performed by Others

    1.2.1. The following preparatory work that must be performed in conjunction with the elevator installation that is to be done by others and is part of the work of other sections.

    1.2.1.1. Hoistway

    1.2.1.1.1. A suitable-fire rated hoistway of proper size and construction conforming to the applicable building codes and elevator construction drawings. Hoistway shall be plumb within 1/2.

    1.2.1.1.2. Provide adequate guide rail supports able to withstand rail forces shown on layout drawings.

    1.2.1.1.3. Provide waterproof pit of adequate design to withstand loads shown on layout drawings.

    1.2.1.1.4. Provide adequate knockouts and sleeves from elevator hoistway to machine room for oil and electrical lines.

    1.2.1.1.5. Provide knockouts for hall stations at each landing.

    1.2.1.1.6. Provide all wall patching, painting and grouting required.

    1.2.1.1.7. Provide finish painting of hoistway doors and frames.

    1.2.1.1.8. Hoistway doors, frames and door hardware by others. (Elevator contractor may furnish).

    1.2.1.2. Machine Room

    1.2.1.2.1. A suitable fire rated machine room of proper size with a lockable door, convenience outlet, and light.

    1.2.1.2.2. Machine room temperature must be maintained between 60 degrees and 100 degrees F, with relative humidity not to exceed 95%.

    1.2.1.2.3. Machine room must be in compliance with ASME A17.1, National EleCode, applicable building codes, and elevator construction drawings.

    1.2.1.2.4. Telephone connection in machine room connected to an outside central exchange where required.

    1.2.1.2.5. Machine room vents as required by local code.

  • Roped Hydraulic Residential Elevator

    6

    Technical Specification

    Canton Residential Spec

    1.2.1.3. Electrical Requirements

    1.2.1.3.1. A 220VAC, single phase service (or optional three phase) with neutral, to a lockable safety disconnect switch, fused with time delay fuses shall be furnished in the machine room in accordance with NFPA 70. A normally open electric interlock contact is required in the switch for