    SYSTEMM

    ANUAL

    2012

    System planning | Orders | Technical service

    Fon +49 (0) 41 94 / 988 11 88 (German landline)

    Fax +49 (0) 41 94 / 988 11 99

    E-Mail [email protected]

    Order division

    Fon +49 (0) 39 33 / 87 99 500 (German landline)

    Fax +49 (0) 39 33 / 87 99 80

    E-Mail [email protected]

    For further information on techniques, products and applications visit

    www.tcsag.de

    ervice | Orders | Support

    Mit uns knnen Sie sprechen.

    System manual

    of audio and video systems for door and building communication

    Mit uns knnen Sie sprechen.

    04-2012 | Subject to technical changes. | Art. VF9058, Version 1.0

    TCS TrControlSysteme AG

    Geschwister-Scholl-Strae 7

    D-39307 Genthin, Germany

    Fon +49 (0) 39 33 - 87 99 10

    Fax +49 (0) 39 33 - 87 99 11

    E-Mail [email protected]

    Web www.tcsag.de

    TCS sterreich GmbH

    Gewerbepark 21

    A-2821 Lanzenkirchen, Austria

    Fon +43 (0) 26 27 - 45 266 0

    Fax +43 (0) 26 27 - 45 266 20

    E-Mail [email protected]

  • 7/26/2019 Tcs System Manual

    2/47

    TCS AG standard terms and conditions of sale

    Pages Chapter Themes Products

    Chapter 1 General information

    02 | 02 1.1 Introduction Notes on using the system manual

    02 | 02 Used symbols | Terminal labelling | List of abbreviations

    Chapter 2System basics

    03 | 03 2.1 Technology TCS:BUS polarity-free 2-wire BUS

    03 | 04 2.2 Wiring TCS audio system and TCS video system

    04 | 05 2.3 Lines Cable conduit and types of lines

    05 | 05 2.4 Connection conditions Specic connection of the oor push-button

    05 | 06 2.5 Loop resistance TCS audio door communication systems principle and measurement

    07 | 07 TCS video door communication systems principle and measurement

    08 | 08 2.6 Cabling Loop through the video signal

    08 | 08 Rising line structure with video distributor

    09 | 09 Star circuit with video distributor

    0 | 10 2.7 Safety and standards Safety instructions | Cleaning | Information on disposal | Conformity

    Chapter 3 Overview products and functions

    2 | 13 3.1 Audio / video front-door stations

    4 | 15 3.2 Audio / video indoor stations

    6 | 16 3.3 Power supplies

    7 | 17 3.4 Extended functions

    Chapter 4 Examples audio door communication systems

    8 | 19 4.1 Standard systems Audio door communication system with up to 20 indoor stations BVS20-SG

    20 | 21 Modernisation of bell systems with up to 20 indoor stations NBV1000

    22 | 23 4.2 Medium-sized and large systems Audio door communication systems with up to 90 indoor stations VBVS05-SG

    24 | 25 Audio door communication systems with up to 3 x 25 indoor stationsBVS100-SG,NWV1000-0400

    26 | 27 4.3 Large systems Audio door communication systems with up to 90 indoor stationsBVS20-SG,NGV1011-0400

    28 | 29 4.4 Sub systemsAudio door communication system in distributed buildings with subsystems and central main front-door stations

    SK10-SG

    30 | 31 4.5 Special systemsSpecial systems from front-door and indoor stations to door andinternal communication

    PSG01-SG,ASI11010-0000

    Chapter 5 Examples video door communication systems

    32 | 33 5.1 Standard systems Video door communication system with up to 12 Video indoor stations VBVS05-SG

    34 | 35 5.2 Video signal distribution Video door communication system with up to 60 video indoor stationsin star structure

    FVY1200-0400,FVY1200-0600,FVY1400-0400

    36 | 37 5.3 Manage video sourcesVideo door communication system with several video fron t-door stationsresp. cameras

    FVU1210-0600,VSW04-SG

    38 | 39Video door communication system with sevral video fron t-door stationsresp. cameras

    VSW04-SG

    40| 41 Video door communication system with video front-door stations on oorsFVU1200-0600,TOER2-EB

    42 | 43 5.4 Systems with two strands Video door communication system with up to 40 video indoor stationsFVY1200-0400,VSW04-SG

    44 | 47 5.5 Central image buffering | Record video images Image buffering in video door communication systems

    FVM1000-0400,BVS20-SG,NGV1011-0400,VBVS05-SG

    f contents

    appears during the limitation period if the defect existed already at the point of risk trans-

    fer. If the supplementary performance is unsuccessful the buyer is entitled to lower thecompensation or to withdraw from the contract. However, the withdrawal is only possible

    if the buyer has previously announced this to us in expressed written form with another

    period of grant. The period of warranty is 24 months. The buyer is entitled to recourseagainst us according to 438 BGB (German Civil Law) only insofar as the buyer has not

    reached an agreement with his customer exceeding the legal fault claims. The buyer is

    entitled to demand compensation for the expenses required for touch provided the ex-penses

    do not increase because the object of the delivery has been moved to a location differentfrom the original place of delivery, provided the transfer is in accordance with its intended

    use.

    DIN/VDE 0100 is to be observed for our technologically high-quality merchandise. Themerchandise is to be hooked up and installed only by an electrician.

    8.1 Simplifed Processing

    We offer a simplied processing of warranty cases to the electrician as follows:

    There is a limitation period for warranty claims due to faulty products of two years

    starting with the proven installation at the nal customer, however, at least three years

    after the production date.

    If the complaint due to faulty products is made within the said periods the manufacturer

    waives the proof of the initial fault.

    The manufacturer waives the proof that the nal customer is a private consumer.

    In the case of complaints due to faulty products the manufacturer delivers replacement free of charge within short period. It is the responsibility of the electrician to send the

    damaged product back to us beforehand or after the exchange is made. On the other hand, the electrician waives the compensation of all further costs of

    replacement or repairing of faulty products. He has to carry these costs himself.

    9. Claims for damages

    We accept claims for damages and expenditure of the buyer (claims of damages), regard-less of the legal argument, particularly due to neglecting the obligations of the debenture

    and prohibited action, only as far as our legal representatives or our vicars have acted in-

    tentionally or recklessly, or if the neglected obligation is of signicance for reaching the

    contract purpose.

    In case of slightly reckless neglect of our contract obligations our compensation is limitedto damage typical for the contract and foreseeable. Compensation is at most twice the

    invoiced value of the products concerned.

    The exclusion of liability and limited liability does not apply as far as we are conclusivelyaccountable for injuring life, body or health or for damages on privately used items accord-

    ing to the law on product liability or because of other reasons.

    10. Extended retention

    The objects of the delivery (retention merchandise) remain the property of the supplier

    until all rights entitled towards the buyer according to the contract have been fullled. As

    long as the value of the security interest that the supplier is entitled to, does exceed the

    amount of all secured claims by more than 20%, the sup plier will release the according partof the security interests if the buyer requests. As far as there are retentions the buyer is not

    permitted to mortgage or to transfer securities. The resale is only permitted to resellers inthe usual course of business and under the condition that the reseller is paid by his cus-

    tomer and that he sets the precondition that the ownership is transferred the customer

    only when he has met his payment obligation.In case of seizure, sequestration, or other action or incursion of third parties, the buyer

    must inform us immediately.

    In case of breach of duty of the buyer, particularly default of payment we are entitled towithdraw from the contract and to retract after an appropriate period has expired unsuc-

    cessfully. The legal regulations about the dispensability of setting a deadline remain un-touched. The buyer is obliged to hand over the merchandise.

    11. Concluding regulations

    The laws of the Federal Republic of Germany s hall apply to these business relationships and

    any and all legal relationships between the customer and us. The provisions of the UN

    Purchase Law shall not apply.Insofar as the customer is a businessperson, a legal person, a public law entity or a special

    fund under pubic law, our commercial residence ( Stendal) shall be the exclusive jurisdictionfor any and all disputes arising directly or indirectly from this contractual relationship.

    In the event that any provision of these Terms and Conditions or a provision within other

    agreements is or becomes invalid, this shall not affect the validity of the other provisions oragreements.

    Genthin, 30.11.2011

    TCS TrControlSysteme AG

    Geschwister-Scholl-Strae 739307 Genthin, Germany

    Fon: +49 (0) 39 33 / 87 99 10

    1. General

    Our supplies, services and offers take place exclusively on the basis of these Terms and

    Conditions. These shall also apply to all future business relationships, even if they are notexplicitly agreed again. Deviating terms and conditions of the customer only apply insofar

    as we have specically agreed to them. In this case, the burden of proof is on the customer.

    These Terms and Conditions are considered to be accepted at the latest upon receipt of t hegoods or the performance of services. We herby contradict any and all adverse conrma

    ions of customers referring to their terms and conditions and/or conditions of purchase.

    2. Prices

    All prices are dened as net prices ex works exclusive costs of cargo and packaging as well

    as turnover taxes. The prices valid on the day of delivery are always invoiced. Especially for

    customised items and deliveries which are made after 4 months after the conclusion of the

    contract, we are entitled to adjust prices due to changes in raw material costs, labour andmaterial costs and / or overheads.

    3. Shipment

    Shipment takes place from the distribution center in Genthin/Germany. We chose the most

    favorable means of transportation and routes. If the buyer has certain requirements theresulting costs are billed separately. The risk passes to the customer, as soon as the delivery

    has been handed over to the transportation or has left our distribution center. In the event

    that the delivery is delayed upon the customers request, the risk shall pass to the cus-tomer

    when the notice is given that the goods are ready for delivery.We do not accept liability for loss or damage. Delivery times are dened by us in such a

    manner that they can be kept within the framework of an orderly course of business.

    Force majeure such as war, labor disputes, operational disruptions, disruptions during thetransport or delays of our suppliers or other events for which we are not responsible, allow

    us to delay the delivery deadline by the duration of the disruption. Should we cause a delay

    of delivery, the buyer is entitled to x a suitable deadline under the penalty of rejection

    with

    a minimum of two weeks. After its expiration the buyer is entitled to cancel the contract in

    written form. The buyer is entitled to compensation due to non-fulllment only if the delay

    is caused intentionally or by recklessness. The buyer is entitled to compensation due to

    non-fulllment only if the delay is caused intentionally or by recklessness and if it has been

    separately agreed in written beforehand. Furthermore, the liability for compensation is

    limited to the delivery value. Further compensation caused by intention or recklessness ofthe supplier remains unaffected by this.

    4. Repurchase

    Orderly delivered merchandise can only be repurchased with our previous written consent.

    For credits for undamaged goods we deduct 15% of the net invoice amount for administra-

    tion costs, control and new packaging. There will be no credit for damaged merchandiseor merchandise with a net invoice amount of less than 50,00 Euro. Custom-made products

    can not be repurchased.

    5. Special versions

    Special versions are only accepted if all technical details have been agreed upon and ifthere

    is an implementation drawing signed by the customer. The stated delivery period begins torun from the received order, from the time that all relevant documents are complete and

    have been received by the supplier. After the production has commenced a cancellation of

    the order is no longer possible.

    6. Exports

    Some foreign representatives or trade partners enjoy a local protection secured by con-

    tract. Therefore, our products may only be exported with our written consent.

    7. Terms of payment

    Our invoices have to be settled within 10 days with 2% early payment discount or within

    30 days strictly net. Early payment discount is only valid for the net value of the merchan-dise, not for freight and packaging. The buyer is not entitled to hold back payment, unless

    notices of defects have arisen with obvious justication.

    Unless otherwise agreed in writing, Payment terms are thirty (30) days. Unless otherwiseagreed in writing payment has to be secured by an irrevocable letter of credit or a bank

    guarantee acceptable to TCS AG . Where payment is made by letter of credit, all costs ofcollection shall be for Buyers account. Cash discount is only granted on the net value of

    the

    merchandise, not on transportation and packaging. The buyer is not entitled to hold backthe payment provided there is no notication of defects that are evident. A counterbalance

    of the buyer is only allowed if there are indisputable and legal counter demands. If thebuyer does not keep deadlines of payments or circumstances are learned that lower the

    buyers credit rating, we reserve to deliver only with cash in advance or cash on delivery or

    demand securities. We reserve to deliver only with cash advance or cash on delivery ordemand securities, where appropriate, we will stop the supply.

    8. Warranty

    There are no warranty claims possible in case of only insignicant aws. If our delivery and

    performance is imperfect and the buyer therefore complains according to 377 HGB (Ger-man code of commercial law) in time and in written form we will supply or repair at our

    choice. We must be granted an appropriate period of at least 10 work days if the defect

  • 7/26/2019 Tcs System Manual

    3/47

    0101

    Page Chapter Topic Products

    Chapter 6 Extended functions and accessory

    48 | 49 6.1 To extend systems | receive video signals Using the video signal on output devices FVW1001-0600

    50 | 51 6.2 To extend systems | release Multi station operation: for systems with more than one front-door stationFAA1100-0600FAA1200-0400

    52 | 53 6.3 To extend systems | switching lights Switching the staircase lights FNA1000-0400

    54 | 55 6.4 Switching and detecting Switching electrical consumersBRE2-SG,BRE2-EB

    56 | 57 6.5 To extend systems | signalling With the radio signal device FFL1000-0

    58 | 59 With the signal device FIL1101-0140

    60 | 61 6.6 To extend systems | calling With the built-in call relay for indoor stations TRE2-EB

    62 | 64 6.7 Connecting desktop accessory For (video) indoor stations ISx3x30-0140 | series IMM | ecoos| sky ZIT

    Chapter 7 Types of installation

    66| 66 7.1 Installation of the front-door stations Series PES for surface-mount with concealed screws PES

    66 | 66 Series AVE for surface-mount with concealed screws AVE

    67| 67 Series PAK for surface-mount with the win:clipsystem PAK

    67 | 67 Series PUK for ush-mount with the win:clipsystem PUK

    67 | 67 Series AVU for ush-mount with the win:clipsystem AVU

    68 | 68 7.2 Installation of the indoor stations Series ISx3x30-0140 for surface-mount ISx3x30-0140

    68 | 68 Series IMM for surface-mount IMM

    69 | 69 Compact indoor station for surface-mount resp. installation into switch frame ISW4210-014x

    69 | 69 Video indoor station ecoosfor installation on ush-mounted socket IVW2111-0140

    70 | 70 Video indoor station skyfor installation on ush-mounted socket IVW2221-015x

    71 | 71 Video indoor station skylinefor ush- and surface-mount IVW3012-0x10

    Chapter 8 Commissioning

    72 | 72 8.1 Manual commissioning Programming bell buttons

    73 | 73 Programming a 2nd indoor station to a bell button

    73 | 73 Status indication of the built-in door loudspeaker ASI11000

    74 | 74 Delete the programming

    75 | 75 8.2 Commissioning with the Service Device Device overview and functions TCSK-01

    76 | 76 Connecting a front-door station

    76 | 76 Commissioning

    77 | 77 Programming bell buttons

    78 | 80 Meaning of the protocol digits

    81 | 81 8.3 Commissioning with the software congo SKX7000-0

    Chapter 9 Service

    82 | 82 9.1 Measuring points

    82 | 82 9.2 FAQ audio door communication systems

    83 | 83 9.3 FAQ video door communication systems

    Chapter 10 Annex

    84 | 87 10.1 Glossary

  • 7/26/2019 Tcs System Manual

    4/47

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    03

    hapter 1 General information

    03

    1.1 Introduction

    Information on using the system manualThe system manual is a practical tool to understand the TCS:BUSsystem.

    For the planning and installation of TCS systems, this system manual provides detailedinformation on products and functions, schematics and wiring diagrams for audio andvideo door communication systems as well as information on installation types andcommissioning.

    Terminal designations

    a TCS:BUS

    b TCS:BUS

    E connection for oor push button

    R connection for door release relay

    P voltage supply

    M mass

    V1 TCS video BUS

    V2 TCS video BUS

    K1 relay contact

    K2 relay contact

    NC relay contact (normally closed)

    NO relay contact (normally open)

    COM changeover contact (common of a changeover switch)

    G connection for shielding

    H auxiliary terminal

    Abbreviations

    ADR address slave video switch

    AP surface-mount

    AS front-door station

    EB built-in housing

    ET oor push button

    FE extended function

    REG DIN-rail housing

    IntSNr serial number of the indoor station, which is addressed by an internal call

    IR illumination infrared illumination

    IS indoor station

    K number of the video input at the video switch

    LED light diode (light-emitting diode)

    ParSNr serial number of the device to which the newly congured device is to be allocated

    TE (SU) separating unit

    TelSNr serial number of the indoor station which sends the control function

    T door opener

    UP ush-mount

    WE at

    ZielSNr serial number of the indoor station which is to be called

    Used symbols

    i

    NoteThis symbol shows importantadditional notes, which have to beobserved when working.

    Symbol for wiring diagramThis symbol shows a twisted pairof wires.

    Symbol for wiring diagramThis symbol shows a shared cablerouting (twisted pair of wires).

    Symbol for wiring diagramThis symbol shows a shared cablerouting (e.g. the wires a, b, P).

    Symbol for wiring diagramThis symbol shows the functionalgrounding.

    TCS:BUS protocols

    Audio technique

    Video technique

    2-wire and 3-wire technique

    2.1 TechnologyThe BUS technology is a system for data transfer between control components.By connecting BUS devices, the system provides functions, processes and theircombination. BUS devices are sensors (command transmitter) and actuators (commandreceiver).

    Principle: All TCS:BUSdevices are connected over one medium, a twisted two-wirecopper line. With this line, signals for switching, controlling, regulating and monitoringare exchanged.The logical connection of the system components is realised with data protocols on theTCS:BUS(wires a/b) instead of single wiring (1+n).

    Installation advantages: minimum wiring effort with conventional conductor material simple types of systems with a centralised voltage supply systems in the most simple form, consisting of only three components functional mixed systems

    2.2 Wiring

    TCS audio systemConcerning in audio technique, the wire pair a/b does stand for voice transmission,switch and detection protocols as well as voltage supply. The P-wire (optionally) realisesan additional voltage supply.This simple 2-wire technique is used in systems with one front-door station. The 3-wiretechnique is needed for larger systems with several front-door stations and a largenumber of indoor stations.

    TCS video system

    For using the video technique (6-wire technique), two further wire pairs are necessaryin addition to the a/b wire pair. The wires P/M stand for the central voltage supply, thetwisted wire pair V1/V2 is needed for the transmission of the video signal.

    Audio technique Video technique

    2 wires for the communication with theTCS:BUS(a / b)

    (optionally) 1 wire for an additionalvoltage supply (P)

    Versorgungs-und Steuergert

    2 twisted wires for the video signal

    (V1 / V2)

    2 wires for the communication with theTCS:BUS(a / b)

    2 wires for a central voltage supply (P / M)

    The communication between the individual BUS devices is realised by sendingTCS:BUS protocols. These protocols are send into the whole system, but onlyacknowledged by the called device.

    The following illustration shows the principle of the TCS:BUScommunication: Sensorssend TCS:BUSprotocols, e.g. a door call to a front-door station (1).Actuators react on sent TCS:BUS protocols, e.g. establishing a voice connection (2).

    Power supplyand control unit

    Power supplyand control unit

  • 7/26/2019 Tcs System Manual

    5/47

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    5

    hapter 2 System basics

    05

    Individual serial number

    Functional principle of the TCS:BUSSensor-actuator-principle

    SN 02

    SN 01

    SN 03

    SN 01SN 02SN 03

    (1)

    Sensor

    Actuator

    (2)

    Sensor

    Actuator

    The structure of the data block is clearly dened. Thus all TCS:BUSdevices can recordand process data. The identical data protocols provide exibility and extensibility for theapplications.

    Advantages of the TCS technology

    The TCS:BUSconnects all TCS:BUSdevices. All system components havea unique and invariable serial number.

    The voltage supply of the systems is realised centrally by a power supply andcontrol unit.

    TCS:BUS systems consist of only three components in their most simple form:A front-door station, an indoor station and a power supply and control unit.

    2.3 Lines

    Cable routing

    The cable routing is dened by structural conditions and is only limited by its length.We recommend to guide the TCS:BUSfrom device to device. The line is connectedat the connection terminals of each device. You can use already existing lines asTCS:BUS lines.

    Type of lines

    As cable material, the following telecommunication lines can be used:

    telecommunication installation line, e.g. J-Y(St)Y

    data cable, e.g. CAT7

    TCS audio system TCS video system

    Polarity-free connection (a/b). V1 (+) and V2 () are notpolarity-free

    Paired wires are permitted: to keep the max. permittedloop resistance, the cross-section of the wires can bedoubled. That means two lines are used for one wire.The lines have to be twisted.

    Doubling the wiresfor V1 / V2 is not permitted!This would cause image interferences!For the wires a/b/P/M it is permitted to increase thecross-section by doubling the wires.

    Wire pairs have to be used. Per cable only one video line (twisted wire pair V1/V2)can be used.

    Stub lines / branches are possible without additionalcomponents.

    Stub lines / branches are onlypermitted with a videodistributor.

    Optionally, a strand or star shaped wiring is possible.

    Optionally, a strand or star shaped wiring is possible.

    The twisted wire pair (V1/V2) can also be routed in thecable of the shielded lines.

    2.4 Connection conditions

    Specic connection of the oor push button

    Usually, the oor push button is connected to the connection terminals a and E.

    If necessary, the oor push button has to be connected to the terminals b and E, if thea-wire at the device is connected with the b-terminal of the power supply and controlunit (permitted exchange of the a/b-wire).

    Alternatively, the connection between P and E is possible, if the P-wire is connectedand supplied.

    2.5 Loop resistanceThe loop resistance is determined signicantly by the type of the used material and thewire cross-section. The loop resistance is length-depending and increases linear to thecable length. If the loop resistance is too high, TCS:BUSdevices cannot communicatereliably with each other.

  • 7/26/2019 Tcs System Manual

    6/47

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    7

    ap 2 Systemgrundlagen

    Loop resistances in TCS audio door communication systems

    The following table shows the loop resistances depending on the installation type (linelength) and on the used installation material (line diameter).

    Loop resistances in TCS video door communication systems

    The following table shows the loop resistances depending on the installation type (linelength) and on the used installation material (line diameter).

    07

    Procedure when measuring

    Switch off 230 V / 50 Hz of the power supply andcontrol unit.

    Install a/b short-circuit at the power supply and controlunit.

    Other devices do not disturb the measuring, they canstay connected.

    Measure the resistance on a/b at the strand of the lastindoor or front-door station, remove short-circuit.

    To measure the loop resistance at P/M proceed as fora/b.

    le for 20 Ohme distance from the TCS:BUS power supply to therthest front-door station or indoor station c an amountmax. 65 m at a wire diameter of 0.6 mm.

    e distance from the TCS:BUS power supply to therthest front-door station or indoor station c an amountmax. 280 m at a wire diameter of 0.8 mm.

    Observe during the installation that the loop resistance can amount to max.20 Ohm!

    Observe during the installation that the loop resistance a/b and P/M canamount to max. 8 Ohm!

    line length in m line diameter = 0.6 mm line diameter = 0.8 mm

    loop resistance in Ohm

    10 1.28 0.71

    20 2.55 1.43

    30 3.83 2.14

    40 5.10 2.86

    50 6.38 3.57

    60 7.65 4.29

    70 8.93 5.00

    80 10.20 5.71

    90 11.48 6.43

    100 12.76 7.14

    150 19.13 10.71

    200 25.51 14.29

    250 17.86

    300 21.43

    line length

    a/b and P/M in m

    l ine dia me te r = 0. 6 mm l ine di ame te r = 0. 8 m m

    loop resistance in Ohm

    10 1.28 0.71

    20 2.55 1.43

    30 3.83 2.14

    40 5.10 2.86

    50 6.38 3.57

    60 7.65 4.29

    70 5.00

    80 5.71

    90 6.43

    100 7.14

    max.20Ohm

    max.20

    Ohm

    a/b,P/M a/b,P/M

    Indoor station

    Indoor stationFront-door station

    Power suply andcontrol unit

    None of the devices front-door station, indoor station or extended functionshould ever be located more than 20 Ohm away from the power supply andcontrol unit!

    Principle loop resistance

    Measuring loop resistance

    a/Mb/P

    a/b short-circuit here

    Ohm

    Indoor station

    Indoor station

    Power supply andcontrol unit

    Front-door station

    Ohm

    Principle loop resistance

    Measurement loop resistance

    max.8Ohm

    max.8O

    hma/b,P/M a/b,P/M

    Indoor station

    Indoor stationFront-door station

    Power supply andcontrol unit

    a/Mb/P

    short-circuit a/b and P/M here

    Ohm

    Indoor station

    Indoor station

    Power supply andcontrol unit

    Front-door station

    Ohm

    None of the devices front-door station, indoor station or extended functionshould ever be located more than 8 Ohm away from the power supply andcontrol unit!

    To be observedLoop resistance > 8 Ohm:Plan multiple wiring of the strands(double twisted wires).

    Rule for 8 OhmThe distance from the TCS:BUS power supply to the fur-thest front-door station or indoor station can amount tomax. 65 m (at a wire diameter of 0.6 mm).

    The distance from the TCS:BUS power supply to the fur-thest front-door station or indoor station can amount tomax. 115 m (at a wire diameter of 0.8 mm).

    ocedure when measuringSwitch-off 230 V / 50 Hz of the power supply andcontrol unit.

    Install a/b short-circuit at the power supply and controlunit.

    Other devices do not disturb the measuring, they canstay connected.

    Measure the resistance on a/b at the strand of the las tindoor or front-door station.

  • 7/26/2019 Tcs System Manual

    7/47

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    9

    ap 2 System basics

    09

    2.6 Cabling

    leSupply max. 20 video indoor stations with one strand.

    If the video indoor station is the last device in theTCS:BUS line, set matching resistor.

    Do not set the matching resistor at the other videoindoor stations.

    Rule If the video indoor station is the last device in the

    TCS:BUSline, set matching resistor.

    Do not set the matching resistor at the other videoindoor stations.

    Video indoor station

    6 (a, b, P, M, V1, V2)

    Power supply andcontrol unit

    Video front-door station

    6

    6

    6

    6

    6

    Video indoor station

    Video indoor station

    6

    6Video indoor station

    Video indoor station

    Video front-door station

    Power supply andcontrol unit

    66 6

    Video indoor station

    Video indoor station

    Video indoor station

    Video indoor station

    6

    6 6 6 6 6 6 6 6

    Video front-door station

    Power supply andcontrol unit

    Video indoor station

    Video indoor station

    Video indoor station

    Video indoor station

    With the power supply and control unit BVS20-SG and the DC power supplyNGV1011-0400 up to 15video distributors (double) and 60video indoor sta-tions are permitted!

    Advantages Disadvantages

    Compensation of conduction loss possible.

    Increased expenditure for devices. Large system structures can be realised with strand

    structure resp. tree structure.

    With the power supply and control unit BVS20-SG and the DC power supplyNGV1011-0400 up to 8video distributors (quadruple) and 60video indoorstations are permitted!

    Star structure with video distributor (quadruple)

    e.g. in case of stub lines from the distribution into the at

    Rising line structure with video distributor (double)

    e.g. rising line with stub line into the at

    Loop through the video signal

    Without using video distributors, in this type of cabling, the video lines are connectedtogether to the terminals V1 and V2 of the video indoor station (loop through). Thereis no branch.

    leIf the video indoor station is the last device in theTCS:BUS line, set the matching resistor.

    Do not set the matching resistor at the other videoindoor stations.

  • 7/26/2019 Tcs System Manual

    8/47

    11

    ap 2 Systemgrundlagen

    11

    ap 2 System basics

    11

    2.7 Safety and standards

    Safety instructions

    Switch off supply voltages before working at the device.

    When working on systems with a main connection of 230 V alternating voltage, thesafety requirements according to DIN VDE 0100 must be observed.

    When installating TCS:BUS systems, the general safety regulations fortelecommunication systems according to VDE 0800 must be observed:

    Separated cabling of heavy and low current lines.

    Minimum distance of 10 cm for common cabling.

    Use of separators between heavy and low current lines in shared cable ducts.

    Use of standard telecommunication lines, e.g. J-Y (St) Y with 0.8 mm diameter.

    Existing lines (modernisation) with deviating cross-sections can be used in compli-ance with the loop resistance.

    With suitable requirements to protect against lightning, it has to be ensured that avoltage of each 32 V DC is not exceeded at the TCS:BUS .

    Cleaning

    Clean the device with a dry or slightly wet cloth. Remove stronger stains with a mildhousehold cleaner.

    Information on disposal

    The adjoining symbol shows that the device has to be disposed separately fromdomestic waste. The materials used are recycable. Please do help protecting ourenvironment and dispose the device via collection point for electronic scrap.

    Dispose the parts of the packaging in collecting tanks for cardboard and paper resp.

    plastics.

    Conformity

    All TCS devices are CE certicated. Declarations of conformity can be downloadedunter www.tcsag.de\Downloads\Handelsinformationen.

    Warranty

    We offer a simplied processing in case of warranty for electricians. Note ourconditions of sale and delivery, to download under www.tcsag.de\Downloads\Handelsinformationen.

    Mounting, installation, commissioning and repair of electronic devices has tobe carried out only by qualifed electricians!

    Prevent water from entering the device!Do not use any abrasive or strong detergents!

  • 7/26/2019 Tcs System Manual

    9/47

    13

    ap 3 Product and function overview

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    13

    Series AVE for surface-mount with up to 88 bell buttons

    Series AVU for ush-mount with up to 24 bell buttons

    Series AD1 | AD2 for ush-mount with up to 200 call destinations

    eries PAK for surface-mount with up to 8 bell buttons

    eries PES for surface-mount with up to 92 bell buttons

    Bell button extensions for the series PES and AVE

    eries PUK for ush-mount with up to 30 bell buttons

    eries TCU for installation behind loudspeaker covers for up to 208bell buttons

    .1 Audio and video front-door stations

    (Video) Front-door stations

    SeriesPAK

    SeriesPES

    SeriesPUK

    SeriesTCU

    SeriesAVE

    SeriesAVU

    SeriesAD1

    SeriesAD2

    System functions

    Allocations per bell button 2 2 2 2 2 2 2 2

    Wiring technique (number of wires) 3 3 3 3 6 6 3 3/6

    Conguration options

    Automatic call cut-off

    Trigger functions

    Door call

    Switching lights

    Door release

    Triggering door release relay

    Switching

    Functions that can be (de-)activated

    Acknowledgement tone *

    Selection and settings

    Volume voice output

    Volume acknowledgement tone *

    Microphone sensitivity

    Length of call 56 s 56 s 56 s 56 s 56 s 56 s 56 s 56 s

    Door stand-by time 56 s 56 s 56 s 56 s 56 s 56 s 56 s 56 s

    Door release time (adjustable factory setting) 3 s 3 s 3 s 3 s 3 s 3 s 3 s 3 s

    Indications

    Status indication

    Housing and installation

    Type of installation AP AP UP EB AP UP UP UP

    Bell buttonschrome-plated fullmetal

    chrome-plated fullmetal

    chrome-plated fullmetal

    chrome-plated fullmetal

    chrome-plated fullmetal

    aluminium aluminium

    Opening principle win:clipcoveredscrews

    win:clipcoveredscrews

    win:clip

    Storage of the system conguration

    Can be functional extended with FAA1100-.. FAA1100-.. FAA1100-.. FAA1100 FAA1100-.. FAA1100-.. FAA1100-.. FAA1100-..

    Video camera

    Detection angle 90 90 90 90

    Type of camera color color color color

    Swivel and incline range no no no no

    Suitable for day-night use

    IR-illumination | max. distance (IR-illumination) | 1 m

    Image sensor 0.8 cm (1/3 inch) Sony CCD

    Resolution in TVL 420 420 420 420

    Light sensitivity in Lux at F 2.0 0.1 0.1 0.1 0.1

    Focal length f 3.7 mm 3.6 mm 3.6 mm 3.6 mm

    Feature is available resp. can be activated Fixed factory setting Only for product version for hands-free talking

    Note *only for the built-in door loudspeaker ASI11000-0000

  • 7/26/2019 Tcs System Manual

    10/47

    15

    ap 3 Product and function overview

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    15

    Door telephone and hands-free talkingdevice ISx3030-0140 for surface-mount with standard functions

    Door telephone and hands-free talkingdevice ISx3130-0140

    for surface-mount with comfort functions

    Compact indoor station ISW4210-014x for surface-mount with comfort functions

    ndoor stations IMMxxx0-014x for surface-mount with additional functions

    Concierge stations series PFS for set up with concierge functions

    .2 Audio and video indoor stations

    Video indoor stations IMMx30x0-014x for surface-mount with additional functions

    Video indoor stations ecoos for surface-mount with comfort functions

    Video indoor station skyfor installation on ush-mount socket with comfort functions

    Video indoor station skylinefor ush-mount with up to 200 calldestinations

    (Video-) Indoor stations

    ISx3030-

    0140

    ISx3130-

    0140

    ISW42x0-014x

    IMM1100-014x

    IMM2100-014x

    IMM1300-014x

    IMM2300-014x

    ecoos

    sky

    skyline

    Systemfunctions

    Voice transmissionduplex c.hands-

    free

    duplex c.hands-

    free

    hands-free

    talking

    duplexcommuni-

    cation

    hands-free

    talking

    duplexcommuni-

    cation

    hands-free

    talking

    hands-free

    talking

    hands-free

    talking

    hands-free

    talking

    Audio / video privacy function, automatic call cut-off

    Operation central image buffer

    Announcement function

    Trigger

    functions

    Door release

    Switching lights

    Switching

    Internal call

    Selective switching 10 + 1 10 + 1 10 + 1 10 + 1

    Selective internal calls 10 + 1 10 + 1 10 + 1 10 + 1

    Selective calls from front-door station 10 10

    Image activation, camera selection

    Image recording in the central image buffer

    Camera control via PTZ interface

    Functions thatcan be (de-)activated

    Simpelx communication

    Automatic hands-free talking after internal call

    Ring tone mute

    Parallel allocation

    Call diversion

    Door release automatic

    Floor door release function

    Selection andsettings

    Number of selectable ring tones 13 13 13 13 13 13 13 13 13 13

    Number of selectable ring tones per bell button (sub door call) 4 4 4 4

    Number of acoustic call distinctions 4 4 4 4 4 4 4 4 4 4

    Ring tone volume

    Conversation volume

    Color intensity, brightness (contrast)

    Indications

    Ring tone mute

    Indication of a busy line

    Door and internal calls (short-term memory)

    Call diversion resp. door release automatic

    Sensor function (status indication)

    Image storaging (in central image buffer)

    Receive short messages

    Housingand installation

    Material and colorsplastics,white

    plastics,white

    plastics,whitesilver

    plastics,whitesilver

    plastics,whitesilver

    plastics,whitesilver

    plastics,whitesilver

    plastics,white

    aluminium,3-colored

    aluminium,silver | black

    Type of installationSurM,

    desktopSurMP,desktop

    SM | FMswitch fr.

    SurM,desktop

    SurM,desktop

    SurM,desktop

    SurM,desktop

    SurM,desktop

    FM-socketdesktop

    SurM | FM

    Can be functional extended withTRE1-EBFFL1000-0FBI4200-..

    TRE1-EBFFL1000-0FBI4200-..

    FFL1000-0FBI4200-..

    FFL1000-0FBI4200-..

    FFL1000-0FBI4200-..

    FFL1000-0FBI4200-..

    FFL1000-0FBI4200-..

    FFL1000-0FBI4200

    FFL1000-0FBI4200-..

    FFL1000-0FBI4200-..

    Magnetic handset cradle

    Video displayDisplay size in cm (inch) and type of display

    6.0 (2.4),active TFT

    6.0 (2.4),active TFT

    8.9 (3.5),active TFT

    8.9 (3.5),digital TFT

    14.5 (5.7),digital TFT

    Resolution in pixel 320 x 234 320 x 234 320 x 234 320 x 240 640 x 480

    Feature that is available resp. can be activated Fixed factory setting Only product version for hands-free talking

  • 7/26/2019 Tcs System Manual

    11/47

    17

    ap 3 Product and function overview

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    17

    TRE1-EB | TRE2-EB Built-in call relay (for indoor stations)

    FAA1100-0600 | TOER2-EB Built-in door release relay (for front-doorstations)

    FAA1200-0400 Door release relay (for DIN-rail housing)

    BRE2-SG | BRE2-EBCombined device with binary input/output,single

    FBS1100-0900 Sensor with binary input, single

    FNA1000-0400 Staircase light control unit

    BVS20-SGfor audio door communication systems withup to 20 indoor stations

    NBV1000for audio door communication systems withup to 20 indoor stations

    VBVS05-SG for audio door communication systems withup to 90 indoor stations

    BVS100-SGfor audio door communication systems withup to 3 x 25 indoor stations

    .3 Power supplies

    unction overview

    ower supplies and control units

    BVS20-SG

    NBV1000

    VBVS05-SG

    BVS100-SG

    ystem functions

    Number of TCS:BUSconnectors 1 1 1 3

    witching output for door opener

    otential-free switching output foroor opener

    otential-free switching output forutomatic light switch units

    lectrical features

    Max. output current at a-terminal 40 mA 40 mA 60 mA 3 x 60 mA

    Max. output current at P-terminal 60 mA 60 mA 600 mA 100 mA

    witchable voltage to release doors (AC) 12 V 12 V 12 Vswitchedvoltage

    Voltage (DC) (Ua/b

    ) in V 2 4 V 1 V 2 4 V 1 V 2 4 V 1 V 2 4 V 1V

    Voltage (DC) (Ub/P

    ) in V 2 4 V 1 V 2 6 V 1 V 2 6 V 1 V 2 4 V 1V

    Dimensions

    eparating units at DIN-rail 4 SU 2 SU (Trafo) 6 SU 6 SU

    3.4 Extended functions

    FFL1000-0Radio signal device with radio transmitterboard

    NGV1011-0400 DC power supply

    NWV1000-0400 Transformer

    Function overview

    Power supplies

    NGV1011-0400

    NWV1000-0400

    Electrical features

    Output current terminal(s) 2.5 A 2 A

    Input voltage 230 V 230 V

    Output voltage 26 V DC 8 V AC

    Dimensions

    Separating units at DIN-rail 8 SU 2 SU

    FVW2000-0600 Two-wire video transmitter

    FVW1001-0600 Two-wire video receiver

    FVU1210-0600 | VSW04-SG Video switch, double and quadruple

    FVU1200-0600 Floor video switch

    FVY1200-0x00 | FVY1400-0400 Video distributor, double and quadruple

    FVM1000-0400 Central image buffer

    FIL1101-0140 Signal device with LED indication

    Feature that is available resp. can be activated Fixed factory setting Only product version for hands-free talking

    Extended functions

    FFL1000-0

    FIL1101-0140

    TRE1-EB

    TRE2-EB

    FAA1100-0600

    FAA1200-0400

    TOER2-EB

    FNA1000-0400

    SK10-SG

    BRE2-SG

    BRE2-EB

    FBS1100-0900

    FBS1105-0900

    BMN2-EB

    FIS1100-0600

    FVY1200-0400

    FVY1200-0600

    FVY1400-0400

    FVU1210-0600

    VSW04-SG

    FVU1200-0600

    FVM1000-0400

    FVW2000-0600

    FVW1001-0600

    Input current I(a)

    in 2-wire operation, in mA 1.5 0.4 1.2 1.2 1.5 1.3 1.3

    in 3-wire operation, in mA 0.4 0.2 0 .4 0.4 0.4 0.4 0.4 0.4 0.4 0 .4 0.4

    in 6-wire operation, in mA 0 .4 0 .4 0 .4 0 .2

    Input current I(P), stand-by in mA 2 1.3 0.8 1.2 0.8 1.4 2.8 1 1 1.1 5 60 40 90 2 21 0 .4 7 0 17

    Input current I(Pmax), max. in mA 7.5 70 6.5 5.6 16 6.5 30 4.4 1.5 1.5 2.5 12 70 60 120 10 0.0 9 130 300

    Supply voltage in V 230 26 26 26 26 26 26 230 230 26 26 26 26 26 26 26 26 26 26 26 26 26 26 26

    Wiring technique

    (number of wires)

    2

    3

    6

  • 7/26/2019 Tcs System Manual

    12/47

    19

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    4.1 Standard systems

    2 (a,b)

    Floor

    Door opener

    3 (a,b,P)

    2

    3 (a,b,P)

    Floor

    Floor

    2-wire technique 3-wire technique

    3 (a,b,P)

    Floor

    Floor

    Floor

    Power supplyand control unitBVS20-SG

    2 (a,b)

    2 (a,b)

    2 (a,b)

    3 (a,b,P)

    3 (a,b,P)

    3 (a,b,P)

    Indoor stations,e.g. door telephone orhands-free talking device

    Power supply-and control unitBVS20-SG

    Front-door station,e.g. series PES

    max. 20 indoor stationspermitted

    ET

    a b P

    b PEa

    ET

    b PEa

    ET

    b PEa

    171615142324 25

    T> 6

    a b

    1 3

    2

    2

    2

    2

    2

    2

    Indoor stations,e.g. door telephone orhands-free talking device

    Indoor stations,e.g. door telephone orhands-free talking device

    Article number

    BVS20-SG Power supply and control unit

    For systems at 1 strand

    1 TCS:BUSconnectorInput voltage: 230 V | 50 / 60 HzPotential-free switching output (closing contact / max. capacityfor automatic light switch units:) 24 V DC / 1 ASwitchable door release voltage 12 V | 50 / 60 Hz, max. 2 AMax. output current a-terminal: I(amax) = 40 mAMax. output current P-terminal: I(Pmax) = 60 mAStrand (a/b) and P-terminal are short-circuit protectedMax. loop resistance: 20 OhmAcceptable ambient temperature: 0 C to +40 CDegree of protection: IP 20Dimensions: H 90 mm x W 72 mm x D 70 mmREG 4 SU according to DIN EN 60715 TH 35 for DIN-railaccording to DIN EN 50022

    pecial case: Connection of the oor push button

    The oor push button is usually connected to the connectionterminals a and E.

    Eventually, the oor push button has to be connected to theterminals b and E, if the a-wire at the device is connected tothe b-terminal of the power supply and control unit (permittedexchange of the a/b-wire).

    Alternatively the connection can be realised between P and E,

    if the P-wire is connected and supplied.

    Audio door communication systems with up to 20 indoor stationswith the power supply and control unit BVS20-SG

    Note In this type of system, all audio front-door stations can be used, except for the series ADx.

    3-wire technique

    2-wire technique

    P

    max. 20 indoor stationspermitted

    Note Max. 20 indoor stations permitted.

    oror or

    8-24 V

    230 V / 50 Hz

  • 7/26/2019 Tcs System Manual

    13/47

    21

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    Modernisation of bell button systems with up to 20 indoor stations with theower supply and control unit device combination NBV1000

    Article number

    NBV1000 Device combination

    For systems at 1 strand, for modernisation

    he device combination can be used to retrot already existing bellutton systems into TCS door communication systems

    There are only 2 wires necessary between the bell transformer inthe control cabinet and the power supply, which is installed nearthe front-door station.Already existing wires of the bell systems can be used.Installing additional lines is not necessary.This combination is advantagous, if only 2 SU for onetransformer are available in the control cabinet.

    ontrol unitFor installation into a deep ush-mount socketInput voltage: 230 V | 50 / 60 HzDoor release voltage 12 V | 50 / 60 Hz, max. 2 AMax. output current a-terminal: I(amax) = 50 mAMax. output current P-terminal: I(Pmax) = 100 mAStrand (a,b) and P-terminal are short-circuit protectedMax. loop resistance: 20 OhmAcceptable ambient temperature: 20 C to +50 CDimensions: H 50 mm x W 50 mm x D 22 mm

    ransformerPower supply for AC voltage 8 V | 50 / 60 HzOutput current terminals: I = 2.0 AInput voltage: 230 V | 50 / 60 HzAcceptable ambient temperature: 0 C to +40 CDimensions: H 93 mm x W 34 mm x D 60 mmREG 2 SU according to DIN EN 60715 TH 35 for DIN-rail

    according to DIN EN 50022

    Note The supply is realised via two bell wires. Max. 20 indoor stations are permitted.

    Indoor station,e.g. door telephone

    Indoor station,e.g. door telephone

    Control unit

    TransformerNWV1000-0400

    Front-door station,e.g. series PUK

    T 21

    51 6

    230 V / 50 Hz8 V AC

    10

    T>6

    a b P

    a b P

    ET

    b PEa

    ET

    b PEa

    Door openerTransformerin the home light distribution

    (230 V / 50 Hz)

    Floor

    2 (8 V AC)

    2 (a,b)

    2

    Control unitat the front-door station

    3 (a,b,P)

    For the remote installation of the power supply,e.g. in the ush-mount box of the front-doorstation

    Particularity:The supply is realised via 2 bell wires

    2 (a,b)

    max. 20indoor stationsare permitted

    2

    8 V AC

  • 7/26/2019 Tcs System Manual

    14/47

    23

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    4.2 Medium-sized and large systems

    Audio door communication systems with up to 90 indoor stationswith the power supply and control unit VBVS05-SG

    2 (a,b)

    2 (a,b)

    2 (a,b)

    Floor Floor

    Door opener

    3 (a,b,P)

    2 (8 V AC)

    3 (a,b,P)

    Floor Floor

    2 (a,b)

    2 (a,b)

    2 (a,b)

    Floor Floor

    2 (a,b)

    or or or

    power supplyand control unitVBVS05-SG

    Front-door station,e.g. series PUK

    Power supply-

    and control unitVBVS05-SG

    2-wire technique: max. 30indoor stations permitted3-wire technique: max. 90indoor stations permitted

    2 2

    22

    2 2

    Indoor stations,

    e.g. door telephone orhands-free talking device

    Indoor stations,e.g. door telephone orhands-free talking device

    Indoor stations,e.g. door telephone orhands-free talking device

    Article number

    VBVS05-SG Power supply and control unit

    For audio and video systems at 1 strand

    1 TCS:BUSconnector1 video connectionPotential-free switching output (closing contact / max. loadcapacity for automatic light switch units): 24 V DC / 1 ASwitchable door release voltage 12 V | 50 / 60 Hz, max. 2 AInput voltage: 230 V | 50 - 60 HzMax. output current a-terminal: I(amax) = 60 mAMax. output current P-terminal: I(Pmax) = 600 mAMax. loop resistance: 20 OhmAcceptable ambient temperature: 0 C to +40 CDegree of protection: IP 20Dimensions: H 90 mm x W 105 mm x D 70 mmREG 6 SU according to DIN EN 60715 TH 35 for DIN-railaccording to DIN EN 50022

    Note In 2-wire technique max. 30indoor stations are permitted. In 3-wire technique max. 90indoor stations are permitted.

    Note For all audio front-door stations, built-in door loudspeaker, bell button extensions are possible.

    19 20 21 22

    a b P

    31Pa b

    T> 6

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    8-24 V

    230 V / 50-60 Hz

  • 7/26/2019 Tcs System Manual

    15/47

    25

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    1 5 6

    230 V AC

    10

    Audio door communication systems with up to 3 x 25 indoor stations with the

    ower supply and control unit BVS100-SG and the transformer NWV1000-0400

    2 (a,b)

    Floor

    Floor

    Floor

    2 (a,b)

    Floor

    Floor

    Floor

    2 (a,b)

    Floor

    Floor

    Floor

    2 (a,b)

    Door opener

    3 (a,b,P)

    or or

    2 (8 V AC)

    2 (a,b)

    TransformerNWV1000-0400

    Indoor station,e.g. door telephone

    Indoor station,e.g. door telephone

    Indoor station,e.g. door telephone

    Power supplyand control unitBVS100-SG

    TransformerNWV1000-0400

    Front-door station,e.g. series PUK

    a ba b

    Power supply and control unitBVS100-SG

    2 2 2

    2 2 2

    2 2 2

    2 (a,b) 2 (a,b) 2 (a,b)

    2 (a,b) 2 (a,b) 2 (a,b)

    2-wire technique: max. 3 x 25indoor stations permitted

    Article number

    BVS100-SG Power supply and control unit

    For systems at 3 strands

    3 TCS:BUSconnectionsInput voltage: 230 V | 50 / 60 HzPotential-free switching output (closing contact / max. loadcapacity): 24 V DC / 1 A for automatic light switch unitsPotential-free switching output (closing contact / max. loadcapacity for door opener): 24 V DC / 1 A; external transformernecessaryMax. output current a-terminals: I(amax) = 3 x 60 mAMax. output current P-terminal: I(Pmax) = 1 x 100 mAMax. loop resistance: 20 OhmAcceptable ambient temperature: 0 C to +40 CDegree of protection: IP 20Dimensions: H 90 mm x W 105 mm x D 70 mmREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Article number

    NWV1000-0400 Transformer

    For supply with AC voltage

    Power supply for AC voltage 8 V | 50 / 60 HzOutput current terminals: I = 2.0 AInput voltage: 230 V | 50 / 60HzAcceptable ambient temperature: 0 C to +40 CDimensions: H 93 mm x W 34 mm x D 60 mmREG 2 SU according to DIN EN 60715 TH 35 for DIN-railaccording to DIN EN 50022

    Note Max. 3 x 25audio indoor stations are permitted.Note In this type of system, up to 3audio front-door stations are permitted, except for display stations. 3-wire technique is not permitted.

    1 3

    a b P

    3233 352120 2829 31 30

    Pba

    8-24 V

    18 19

    T> 6

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    8 V AC

    230 V / 50 Hz

  • 7/26/2019 Tcs System Manual

    16/47

    27

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    4.3 Large systems

    Audio door communication systems with up to 90 indoor stations in combination with theower supply and control unit BVS20-SG as well as the DC power supply NGV1011-0400

    3 (a,b,P)

    Floor

    Floor

    Floor

    Floor

    3 (a,b,P)

    Floor

    Floor

    Floor

    Floor

    3 (a,b,P)

    Floor

    Floor

    Floor

    Floor

    3 (a,b,P) 3 (a,b,P)

    Door opener

    3 (a,b,P)

    or or

    3 (a,b,P)

    3-wire technique: max. 90indoor stations are permitted

    3 (a,b,P) 3 (a,b,P) 3 (a,b,P)

    3 (a,b,P) 3 (a,b,P) 3 (a,b,P)

    Power supplyand control unitBVS20-SG

    DC power supplyNGV1011-0400

    (b,P)

    Indoor station,e.g. door telephone

    Indoor station,e.g. door telephone

    Indoor station,e.g. door telephone

    Front-door station,e.g. series PUK

    Externalterminal connection

    Power suppliesand control unitsBVS20-SG andNGV1011-0400

    3 (a,b,P)

    2 2 2

    2 2 2

    2 2 2

    2 2 2

    Article number

    BVS20-SG Power supply and control unit

    For systems at 1 strand

    1 TCS:BUSconnectorInput voltage: 230 V | 50 / 60 HzPotential-free switch output (closing contact / max. load capacityfor automatic light switch units): 24 V DC / 1 ASwitchable door release voltage 12 V | 50 / 60 Hz, max. 2 AMax. output current a-terminal: I(amax) = 40 mAMax. output current P-terminal: I(Pmax) = 60 mAStrand (a/b) and P-terminal are short-circuit protectedMax. loop resitance: 20 OhmAcceptable ambient temperature: 0 C to +40 CDegree of protection: IP 20Dimensions: H 90 mm x W 72 mm x D 70 mmREG with 4 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Article number

    NGV1011-0400 DC power supply

    To supply with DC voltage

    he DC power supply is a switching power supply with a igh degree of efciency to supply the system with voltage.

    Output current terminal 29 (DC out): I(+) = 2.5 AInput voltage: 230 V (196 to 265 V) | 50 / 60 HzOutput voltage: 26 V DC()-terminal is short-circuit protectedDimensions: H 90 mm x W 140 mm x D 77 mmREG with 8 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Note Max. 90indoor stations are permitted. Connect P-terminal at the DC power supply with the P-terminal of the indoor station.

    Note In this type of system, up to 5 video front-door stations of all series can be used, except for the series ADx.

    2 (8 V AC)

    1 3

    230 V / 50 Hz

    a b P

    75

    230 V AC

    +

    BVS20-SG NGV1011-04009

    8-24 V

    14 15 16 17 29

    312324

    P

    T>6

    25

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

  • 7/26/2019 Tcs System Manual

    17/47

    29

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    Wiring diagram

    Audio door communication systems in several buildings with sub systems

    nd central main front-door station with the front-door station coupler SK10-SG

    4.4 Sub systems

    Indoor station,e.g. door telephone

    Indoor station,e.g. door telephone

    Front-door station,e.g. series PES

    Front-door station,e.g. series PES

    Power supplyand control unitBVS20-SG

    Power supplyand control unitBVS20-SG

    Front-door station couplerSK10-SG

    Main front-door station,e.g. series PUK

    4. Building

    3 3 3

    2 or 3 2 or 3

    2

    2 or 3

    Building

    1

    Building

    2

    Building...

    e.g. power supplyand control unitBVS20-SG

    Front-door stationcoupler SK10-SG

    Door opener

    oror

    ba P

    a b P

    1 3

    230 V AC

    1 3

    1 3

    8-24 V

    a b P

    230 V AC

    230 V AC

    20 21

    14 15 16 1724 2523

    P

    P

    2524 23 2726 28 3029 31 32 3 3

    24 2523

    P

    1514 16 17

    T> 6

    T> 6

    T> 6

    a

    a b a b baa b

    b

    ab

    Gate

    ba

    Article number

    SK10-SG Front-door station coupler, quadruple

    To couple front-door stations in sub systems

    he front-door station coupler connects 1 main front-doortation with 1 out of max. 4 sub systems.

    Interconnection with up to 5 SK10-SG is possible(for up to 20 sub systems)Status indication for the active connection with the sub systemInput voltage: 230 V ( 10%) | 50 / 60 HzDoor release function with integrated supply voltage:12 V | 50 / 60 Hz, 2 A (door opener 6 Ohm)Strand and P-terminal are short-circuit protectedMax. loop resistance: 20 OhmAcceptable ambient temperature: 0 C to +40 CDimensions: H 90 mm x W 105 mm x D 70 mmREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Note Connect the main front-door station to SK10-SG via the terminals 23, 24, 25. Do not connect any indoor station to SK10-SG. Max. load capacity of the P-terminal: 150 mA.

    22

    2

    2

    3

    3. Building

    Strand 1 S tr an d 2 S tr an d 3 S tr an d 4

    2 (8 V AC)

    1. Building

    2. Building

    Gate

    Note In this type of system, all audio front-door stations can be used. Set the sender AS-address at the main front-door station with the Service Device TCSK-01.

    ET

    b PEa

    ET

    b PEa

    ET

    b PEa

    8-24 V

  • 7/26/2019 Tcs System Manual

    18/47

    31

    hapter 4 Examples audio systems

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheets

    pecial system of front-door and indoor stations for door and internal communication with theower supply and control unit PSG01-SG and the built-in door loudspeaker ASI11010-0000

    4.5 Special systems

    Power supplyand control unitPSG01-SG

    Concierge stationseries PFS

    Front-door stationNPAK

    Built-in door loudspeakerfor special systemsASI11010-0000

    3+2

    3+2 3

    3+2

    Concierge station,e.g. series PFS

    Front-door statione.g. series NPAK

    Power supplyand control unitPSG01-SG

    for example: barrier systems

    Door opener

    Door opener

    Connection terminals for controls

    Article number

    ASI11010-0000 Built-in door loudspeaker (special sys.)

    For large and special systems with long lineswith 1 strand

    his built-in door loudspeaker is used in systems with alarmnd announcement functions. The device can be installed e.g.ehind loudspeaker covers, front panels, lifts or letter boxes.specially for environments with loud ambient noise, the vo-ume can be adjusted according to the existing requirements.

    Only permitted in conbination with a concierge station forspecial systemsMax. 3 built-in door loudspeakers per strand permittedCan be integrated in multi-storey, lift, medical practices, intercomcashpoint systems as well as behind loudspeaker covers providedby customerInput current: I(a) = 0.1 mA, I(P) = 4 mA (stand-by)Max. input current: I(Pmax) = 80 mAMax. loop resistance: 60 OhmAcceptable ambient temperature: 25 C to +50 CDimensions: H 79 mm x W 112 mm x D 34 mm

    Article number

    PSG01-SG Power supply and control unit

    For large and special systems with long lineswith 1 strand

    Status indication for active connection with the sub systemInput voltage: 230 V ( 10%) | 50 HzOutput current a-terminal: I(a) = 60 mAOutput current P-terminal: I(P) = 600 mAOutput voltage: U(a/b) = 24 V 1 V, U(b/P) = 26 V 1 VDoor release voltage: U(T) = 12 V 2 V, 50 HzDoor release function with integrated supply voltage: 12 V |50 / 60 Hz / 2 A (door opener 6 Ohm)Strand and P-terminal are short-circuit protectedMax. loop resistance: 60 Ohmacceptable ambient temperature: 0 C to +40 CDimensions: H 90 mm x W 105 mm x D 70 mmREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Note Connect max. 3front-door stations of the series NPAK01-EN to one strand. ASI11010 is only permitted in combination with a TCS concierge station for special systems. The combination of ASI11010 and TCKE is not possible.

    2 (8 V AC)

    2 Built-indoor release relayFAA1100-0600

    Built-indoor release relay

    FAA1100-0600

    Built-in door loudspeakerfor special systemsASI11010-0000

    a b P

    a b P

    1 3

    1 2

    20 21 22

    T

    2930 31

    a b R P

    18

    T>6

    H

    T

    8-24 V

    230 V / 50 Hz

    8-12 V

    > 6

    Ta1 Ta1+ S11Ta2+Ta2 S 12 S 21 S 22

    P NC NOCOMR

    Note Concierge station series PFS can only be configured with the s oftware PFS configurator and FBI1200.

  • 7/26/2019 Tcs System Manual

    19/47

    hapter 5 Examples video systems

    33

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Video door communication system with up to 12 video indoor stationswith the power supply and control unit VBVS05-SG

    Door opener

    6 (a,b,P,M,V1,V2)

    2 (8 V AC)

    Floor

    6 (a,b,P,M,V1,V2)

    6 (a,b,P,M,V1,V2)

    6 (a,b,P,M,V1,V2)or or

    Floor

    Floor

    Power supplyand control unitVBVS05-SG

    Place matching resistor at thelast video indoor station!

    Video indoor station,e.g. ecoosTM

    Video indoor station,e.g. ecoosTM

    Video indoor station,e.g. ecoosTM

    Power supplyand control unitVBVS05-SG

    Video front-door station,e.g. series AVE

    ET

    ET

    a b E

    ET

    b Ea

    a b E

    a b P

    8-24 V

    31

    230 V / 50-60 Hz

    M

    P M

    P M

    P M

    G

    19 20 21 2232 33

    V1 V2

    V1 V2

    V1 V2

    V1 V2

    P

    2930 31

    V2V1ba

    T> 6

    2

    2

    2

    6 (a,b,P,M,V1,V2)

    Article number

    VBVS05-SG Power supply and control unit

    For audio and video systems at 1 strand

    1 TCS:BUSconnector1 video connectionPotential-free switching output (closing contact / max. loadcapacity for automatic light switch units): 24 V DC / 1 ASwitchable door release voltage 12 V | 50 / 60 Hz, max. 2 AInput voltage: 230 V | 50 - 60 HzMax. output current a-terminal: I(amax) = 60 mAMax. output current P-terminal: I(Pmax) = 600 mAMax. loop resiatnce: 20 OhmAcceptable ambient temperature: 0 C to +40 CDegree of protection: IP 20Dimensions: H 90 mm x W 105 mm x D 70 mmREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Note Connect the twisted wire pair V1 / V2 of the video front-door station directly to the video indoor station. Connect the wires M and b to the b-terminal of the power supply and control unit VBVS05-SG.

    Note All video front-door stations with video camera can be used, except for display stations. Max. 12video indoor stations are permitted.

    .1 Standard systems

    Max. 12video indoor stations are permitted

  • 7/26/2019 Tcs System Manual

    20/47

    hapter 5 Examples video systems

    35

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Video door communication system with up to 60 video indoor stations in star structurewith the video distributors FVY1200-0400 or FVY1200-0600

    Door opener

    6

    22

    Externalterminal connection

    6

    6 6 6 6 6 6 6

    6

    6

    Max. 20video indoor stations per strand are permitted.

    max.

    200m(

    0.8

    )

    or or or

    6

    DC power supplyNGV1011-0400

    Video distributor,quadrupleFVY1400-0400

    Power supplyand control unitBVS20-SG

    Video indoor station,z. B. ecoosTM

    Power supplyand control unitBVS20-SG,NGV1011-0400

    Video distributorFVY1400-0400

    Video front-door stationsor video cameras

    Video distributorFVY1400-0400

    Video indoor station,e.g. ecoosTM

    Place matchingresistor at thelast video indoorstation!

    Place matchingresistor at thelast video indoorstation!

    Max. 20videoindoor stations

    Max. 20videoindoor stations

    Max. 15video distributorsFVY1400-0400 are permitted.

    Place matching resistor at thelast video distributor!

    914 15 16 171 3

    +

    75

    6 75 9

    ET ET

    V2

    765 9

    INPUT

    ET

    P ME

    ET

    P ME

    OUTPUT 1 OUTPUT 2 OUTPUT 3 + 4

    30 - 35 ... 12 - 17

    T> 6

    2827 2924 252221 2318 19 20 26

    29 3 1

    NL

    2324 25

    2221 2318 19 20 2827 2924 25 26 30 - 35 12 - 17

    4

    4 8

    8

    66

    6 6

    Article number

    VY1200-0400 Video distributor, double

    To supply up to 2 strands with video signals

    his video distributor receives a video signal and distributest to two independent outputs. Depending on the DC powerupply, several video distributors can be operated in oneystem.

    Brightness and contrast per strand can be adjusted: 0 to +12 dBInput current: I(a) = 0.0 mA, I(P) = 60 mAMax. input current: I(Pmax) = 70 mAInput voltage: 26 V DC (from P-wire)Input / output impedance: 100 Ohm balancedAcceptable ambient temperature: 0 C to +40 CREG with 4 SU for DIN-rail mounting according toDIN EN 60715 TH 35

    Article number

    FVY1200-0600 Video distributor, double, ush-mount

    To supply up to 2 strands with video signals

    Alternative to the installation into ush-mount socket andwith performance features as FVY1200-0400,

    eviating from that:Degree of protection: IP 20, installation into ush-mount socketOnly brightness can be adjustedOutput level can be adjusted: 0 to +12 dBInput current: I(a) = 0.0 mAMax. input current: I(Pmax) = 60 mA

    Dimensions: H 52 mm x W 52 mm x D 23 mm

    Article number

    VY1400-0400 Video distributor, quadruple

    To supply up to 4 strands with video signals

    Output level per strand can be adjusted: 3 to +9 dBInput current: I(a) = 0.0 mAMax. input current: I(Pmax) = 120 mAInput voltage: 26 V DC (from P-wire)Input / output impedance: 100 Ohm balancedAcceptable ambient temperature: 0 C to +40 CREG with 6 SU for DIN-rail according to DIN EN 60715 TH 35

    Note Place matching resistor at the last video indoor station. Place matching resistor at the last video distributor.

    Note All (video) front-door stations with video camera can be used. Max. permitted number of video distributors (quadruple):2 (in series circuit), 15 (in parallel circuit). Max. 20video indoor stations per strand are permitted.

    .2 Video signal distribution

    6

    6

    6

    2 (8 V AC)

    Max. 2video distributor in series circuit, 15in parallel circuit are permitted

    OUTPUT 1 OUTPUT 2 OUTPUT 3 + 4

    NGV1011-0400BVS20-SG

    230 V 230 V

    8-24 V

  • 7/26/2019 Tcs System Manual

    21/47

    hapter 5 Examples video systems

    37

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Wiring diagram

    Video door communication systems with several video front-door stations resp.ideo cameras with the video switch FVU1210-0600 or VSW04-SG

    To the voltage supplier and video indoor stations

    Video switch,doubleFVU1210-0600

    6

    6

    6 6

    Video switch,quadrupleVSW04-SG

    6

    6

    Door opener

    DC power supplyNGV1011-0400

    Power supplyand control unitBVS20-SG

    6

    Externalterminal connection

    Video switchFVU1210-0600

    Video front-door stationsor video cameras

    Video indoor station,e.g. ecoosTM

    Video switchVSW04-SG

    Video front-door stationsor video cameras

    ba a

    a b P MG a b P M

    Pb P V1 V2 V1 V2 V1 V2

    V1 V2 V1 V2

    M

    Place matching resistor at thelast video indoor station!

    1567

    V2

    2223 2

    b Ea

    14 15 16 17

    T> 6

    1

    ET

    3

    BVS20-SG

    +

    2 9 31

    NL

    2324 25

    19 202118 2829 25 262724 3435 31 323330 M3 4

    6

    Videoinput 1

    Videoinput 2

    Videooutput

    To the voltage supplierand video indoor stations

    Article number

    VSW04-SG Video switch, quadruple

    For specic selection of 1 out of up to 4 cameras

    his video switch can be used to switch between 4 videoignals to 1 (or several) video indoor station(s). The supply isealised with a DC power supply.

    For specic selection of 1 out of up to 4 camerasInterconnection of up to 5 VSW04-SG is possible(for automatic switch of 1 out of up to 16 cameras)Input current: I(a) = 0.4 mA, I(P) = 21 mA (stand-by)Subscriber identication (AS-address) ex works: 1, 2, 3, 4 /can be adjusted manually and with Service DeviceAcceptable ambient temperature: 0 C to +40 CREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Article number

    VU1210-0600 Video switch, double, ush-mount

    For specic selection of 1 out of up to 2 cameras

    his video switch is used to switch between 2 video signalso 1 (or several) video indoor station(s).

    Degree of protection: IP 20, installation into ush-mount socketInput current: I(a) = 0.4 mA, I(P) = 2.0 mAMax. input current: I(Pmax) = 10 mAInput voltage: 24 V DCSubscriber identication (AS-address) ex works: 1, 2 / can be adjusted manually and with Service DeviceControlling and indicating of the operation modes of the systemAcceptable ambient temperature: 20 C to +50 CDimensions: H 52 mm x W 52 mm x D 23 mm

    Note Camera inputs which are not used can be deactivated. Place matching resistor at the last video indoor station.

    Note All video front-door stations and video indoor stations with video camera can be used. When programming the video front-door stations with the Service Device TCSK-01 or the configurationsoftware configo, set the subscriber identification (AS-address) in the video front-door station.

    Power supplyand control unitBVS20-SG,NGV1011-0400

    .3 Manage video sources

    2 (8 V AC)

    (b,P)

    Auxiliarterminal

    Auxiliarterminal

    Output

    Camera input 3Camera input 2Camera input 1

    230 V

    hold step

    NGV1011-0400

    8-24 V

    230 V

  • 7/26/2019 Tcs System Manual

    22/47

    hapter 5 Examples video systems

    39

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Video door communication system with several video front-door stations resp.ideo cameras with the video switch VSW04-SG

    To the video indoor stations

    6 6 6

    Master

    6 6

    SlaveVideo switch,quadrupleVSW04-SG

    Video switch,quadrupleVSW04-SG

    6 6

    66

    6

    Video switchSlaveVSW04-SG

    Video switchMaster

    VSW04-SG

    Video front-door stationsor video cameras

    Video front-door stationsor video cameras

    Place jumper

    13 1412

    V2

    230 V

    167 2

    V2 a b V2

    567

    24-29 30-35

    30-35...

    2223 19 202118

    2829 25 2627242223 19 2021

    1517 16

    13 1412 1517 1618 3 1 2

    5 3

    Power supply and control unit

    Camera input S1 Camera input S2 Camera input S4

    Note Don't place jumper for master. Set fixed jumper for slave.

    Note All video front-door stations with video camera can be used.

    Article number

    VSW04-SG Video switch, quadruple

    For specic selection of 1 out of up to 4 cameras

    his video switch is used to switch between 4 video signalso 1 (or several) video indoor station(s). The supply is realised

    with a DC power supply.

    For specic selection of 1 out of up to 4 camerasInterconnection of up to 5 VSW04-SG is possible(for automatic switch of 1 out of up to 16 cameras)Input current: I(a) = 0.4 mA, I(P) = 21 mA (stand-by)Subscriber identication (AS-address) ex works: 1, 2, 3, 4 /can be adjusted manually and with Service DeviceAcceptable ambient temperature: 0 C to +40 CREG with 6 SU according to DIN EN 60715 TH 35 for DIN-rail

    mounting according to DIN EN 50022

    Power supplyand control unit

    To the video indoor stations

    Auxiliarterminal

    hold step

    Auxiliarterminal

    hold step

    Camera input S4Camera input S1

    Output

    Output

  • 7/26/2019 Tcs System Manual

    23/47

    hapter 5 Examples video systems

    41

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Wiring diagram

    1. Floor

    Functional diagram

    1. Floor

    Video door communication system with video front-door stations on oorswith the oor video switch FVU1200-0600

    6+2

    Further video distributor, double

    Dooropnener

    6+2

    2

    2

    Externalterminal connection

    or

    2

    6+2

    2

    6

    6

    2

    3+2

    Floordoor opener

    6

    6

    2

    Floordoor opener

    6+2

    6+2

    Built-in doorrelease relayFAA1100-0600

    Power supplyand control unitBVS20-SG

    DC power supplyNGV1011-0400

    Optionally:transformerNWV1000-0400

    Floorvideo switchFVU1200-0600

    Door release relayTOER2-EB

    Video distributor,doubleFVY1200-0600

    Video distributor,doubleFVY1200-0600

    Floor-video switchFVU1200-0600

    Door release relayTOER2-EB

    6+2

    3+2

    Video distributorFVY1200-0600

    Power suppliesand control unitsBVS20-SG, NGV1011-0400,NWV1000-0400

    Video indoor station,e.g. ecoosTM

    Floor video switchFVU1200-0600

    Door release relayTOER2-EB

    Video indoor station,e.g. ecoosTM

    Door release relayTOER2-EB

    Floor videofront-door station,e.g. series PES

    Video distributorFVY1200-0600

    Floor video switchFVU1200-0600

    Video front-door station,e.g. series AVE

    Externalterminal connection

    Floor video front-doorstation,e.g. series PES

    or or

    V2 V1 V1 V2 V1 V2

    V1 V 2 V1 V 2 V1 V 2

    V1 V2 V1 V2 K1 K2

    ET

    T> 6~

    V1 V2

    V 1 V2

    23 25

    T> 6

    ~

    V2 V1 V1 V2 V1 V2

    V1 V 2 V1 V 2 V1 V 2

    V1 V2 V1 V2 K1 K2

    ET

    T> 6

    Pb MEa Mba P ba P

    M

    a a b b P P

    P b a

    Pb MEa Pb Ma Pba

    a a b b P P

    M P b a

    ~ ~Mba P

    8-24 V

    BVS20-SG 914 15 16 171 3 75

    L

    29 31

    a b +

    N

    P

    NGV1011-0400

    230 V230 V

    24

    Auxiliar terminal

    NWV1000-0400 1

    ba

    Video Out1 Video Out2

    FVY1200-0600

    IVW2210 VPDS01 TOER2-EB

    FVY1200-0600

    Video Out1 Video Out2

    FVU1200-0600

    IVW2210 VPDS01 TOER2-EB

    Video IN

    Video IN

    R P M

    P NC NOCOM H

    230 V8 V AC

    5 6 10

    M

    M

    Auxiliarterminal

    Auxiliarterminal

    Note Place matching resistor ... at the last video indoor station the last video floor switch the last video distributor.

    Note All (video) front-door stations with video camera can be used. Set the subscriber identication in the (video) front-door station when programming the TOER2-EB with

    the Service Device TCSK-01 or with the conguration software congo.

    Article number

    TOER2-EB Door release relay for the TCS:BUS

    Specic door release if more than 1 front-door st.

    he door release relay is used for the specic door release,f several front-door stations and door opener are installedwithin one system.

    With own TCS:BUSconnector for location-independentinstallationControlling of additional bells and signal devicesEvaluation of special key functions of the indoor stationDoor release times ex works: 2 seconds / can be conguredwith Service Device or congo

    Degree of protection: IP 20, installation into ush-mount socketInput current (2-wire): I(a) = 1.2 mAInput current (3-wire): I(a) = 0.4 mA, I(P) = 0.8 mAMax. input current (3-wire): I(Pmax) = 6.5 mAMax. line diameter: 0.8 mmAcceptable ambient temperature: 20 C to +50 CDimensions: H 52 mm x W 52 mm x D 23 mm2- as well as 3-wire technique (max. 10 devices are permitted in2-wire technique)

    Article number

    VU1200-0600 Floor video switch

    For specic switching between oor and mainfront-door station

    his video switch is used for the specic switching betweenwo video signals (main front-door station or oor videotation) to one video indoor station.

    One oor video switch is necessary for each at.

    Device is only permitted in combination with a video distributorDegree of protection: IP 20, installation into ush mount socketMax. loop resistance: 20 OhmProgramming with Service Device, with congo , manuallyAcceptable ambient temperature: 0 C to +40 CEMV standard according to EN 50081 and EN 50082-2,Radio interference suppression according to EN 55011Dimensions: H 52 mm x W 52 mm x D 23 mm

    Built-in door release relayFAA1100-0600

    FVU1200-0600

    R

    Video OUTScreen

    Video OUTScreen

  • 7/26/2019 Tcs System Manual

    24/47

    hapter 5 Examples video systems

    43

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Wiring diagram

    Video door communication system with up to 40 video indoor stationswith the video distributor FVY1200-0400 and the video switch VSW04-SG

    Door openerDoor opener

    6 6

    6 6

    6 6

    6 6

    Max. 20video indoor stationsper strand permitted

    6+2

    6+2

    3+23+2

    6+26+2

    22

    Power supplyand control unitBVS20-SG

    DC power supplyNGV1011-0400

    Video switchVSW04-SG

    Video distributorFVY1200-0400

    Place matching resistor at thelast video indoor station!

    Video indoor stations,e.g. ecoosTM

    Video indoor stations,e.g. ecoosTM

    Video indoor stations,e.g. ecoosTM

    Video distributorFVY1200-0400

    Power suppliesand control unitsBVS20-SG,NGV1011-0400

    Video switchVSW04-SG(alternateFVU1200-0600)

    Door release relayTOER2-EB

    Video front-door station,e.g. series AVE

    3-wire connectionactivated!

    Place matching resistor at thelast video distributor!

    P V1Mb V2

    21

    9

    a b P

    5 367 4

    V2V1 V2 a b P V1 V2

    14 15 16 171 3 75

    P V1Mb V2P V1Mb V2

    ET

    Pb V1M V2E

    ET

    Pb V1M V2E

    ET

    Pb V1M V2E

    ET

    Pb V1M V2E

    a b P V2K1 K2 a b P V2K1 K2

    ET

    Pb V1M V2E

    ET

    Pb V1M V2E

    L

    29 312324 25

    2223 1 9 202118

    S1 S2

    2829 25 262724

    V1 V2

    > 6> 6

    M

    a a

    a a

    aa

    a a a

    a b +

    N

    ba

    P

    P

    M M

    V1 V2V1 V2ba P ba P

    OUTPUT 1 OUTPUT 2

    INPUT

    BVS20-SG NGV1011-0400230 V230 V

    hold stepOutput

    Camera input 1 Camera input 2

    8-24 V

    Note Max. 20video indoor stations per strand are permitted. Place matching resistor at the last video indoor station.

    Note Max. 20video indoor stations per strand are permitted.

    Article number

    VY1200-0400 Video distributor, double

    To supply up to 2 strands with video signals

    he video distributor records a video signal and distributest to two independent outputs. Depending on the DC powerupply, several video distributors can be operated wtihin oneystem.

    Brightness and contrast per strand can be adjusted: 0 to +12 dBInput current: I(a) = 0.0 mA, I(P) = 60 mAMax. input current: I(Pmax) = 70 mAInput voltage: 26 V DC (from P-wire)Input / output impedance: 100 Ohm balancedAcceptable ambient temperature: 0 C to +40 CREG with 4 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Article number

    VSW04-SG Video switch, quadruple

    For specic selection of 1 out of up to 4 cameras

    his video switch is used to switch between 4 video signalso 1 (or several) video indoor station(s). The supply is realised

    with a DC power supply.

    For specic selection of 1 out of up to 4 camerasInterconnection of up to 5 VSW04-SG possible(for automatic switch-over of 1 out of up to 16 cameras)Input current: I(a) = 0.4 mA, I(P) = 21 mA (stand-by)AS-addresses ex works: 1, 2, 3, 4 /can be adjusted manually and with the Service DeviceAcceptable ambient temperature: 0 C to +40 CREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    .4 Systems at two strands

    T T

    Max. 20video indoor stationsper strand permitted

    Auxiliar-terminal

  • 7/26/2019 Tcs System Manual

    25/47

    hapter 5 Examples video systems

    45

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Wiring diagram

    System exampleone-family home

    Functional diagram

    System exampleone-family home System exampleexclusive central image buffer

    System exampleLarge systems

    mage storage in video door communication systems

    with the central image buffer FVM1000-0400

    Video indoor station,e.g. ecoosTM

    Central image bufferFVM1000-0400

    Power supplyand control unitVBVS05-SG

    Video front-door station,e.g. series AVE

    Place matching resistor at thelast video indoor station!

    Place matching resistor at thelast central image buffer!

    ET

    b PG

    > 6

    b P

    E PP M

    19 20 21 2230 31 29 32 33

    T

    OUTPUT

    INPUT

    Note Place matching resitor at the last video indoor station. Switch matching resistor J1 to ON at the last central image buffer.

    Note All video front-door stations with video camera can be used.

    Article number

    VM1000-0400 Central image buffer

    For extended functions of video systems

    he central image buffer is a seperated storage to recordingle images and image series of 1 to 4 images.

    Image resolution (color) 720 x 576 pixelImage buffering on SD cardImage buffer for up to 2.048 images (64 per at)Image encoding (can be activated)Acoustic and optical error indicationManual snapshotThree operation modes can be adjusted

    Operation mode: one-family homeConguration of serial numbers is not necessaryOperation via image button and function keyImage buffer for up to 512 imagesConguration with congoor infrared remote controlSnapshot after door call at video indoor stationWithout discretion restriction

    Operation mode: basicMax. number of ats: 32Conguration of serial numbers with congo or infraredremote control necessaryOperation via image button and function keySnapshot after door call at video indoor stationDiscretion restriction: image recording only of door calls whichare addressed to this at

    Operation mode: comfortMax. number of ats: 32LED indication at video indoor stationOperation via OSD menu (video indoor station)

    Conguration with congo

    or infrared remote controlSetting date / time at the video indoor stationAutomatic recording (can be activated / deactivated)Discretion restriction: image recording and reproductiononly of door calls which are addressed to this at

    echnical data:Input current: I(a) = 0.13 mA, I(P) = 67 mA (stand-by)Max. input current: I(Pmax) = 130 mAInput voltage: U(P) 26 V DCInput / output impedance: 100 Ohm2-wire video signal: output level (can be adjusted manually)Acceptable ambient temperature: 0 C to +50 CDimension: H 104 mm x W 90 mm x D 70 mmREG with 6 SU according to DIN EN 60715 TH 35 for DIN-railmounting according to DIN EN 50022

    Video front-door station

    Power supply and control unitVBVS05-SG

    Central image bufferFVM1000-0400

    Video indoor stationwith image buffer function

    Video front-door station

    Video indoor stationwith image buffer function

    Video indoor stationswithout image buffer function

    Central image bufferFVM1000-0400

    Power supply and control unitBVS20-SG

    NGV1011-0400

    Video front-door stations

    Power supplies and control unitsBVS20-SG

    NGV1011-0400

    Video switchVSW04-SG

    Video indoor stationwith image buffer function

    One central image bufferfor each sub system

    FVM1000-0400

    .5 Central image storage | Record video images

    230 V / 50-60 Hz

    8-24 V

  • 7/26/2019 Tcs System Manual

    26/47

    hapter 5 Examples video systems

    47

    Functional diagram Wiring diagram

    Technical hotline

    [email protected]

    www.tcsag.de

    Download product data sheet

    Wiring diagram

    System exampleLarge system

    Functional diagram

    System exampleexclusive central image buffer

    Video indoor station,e.g. SkyTM

    Central image bufferFVM1000-0400

    Video front-door station,e.g. series AVE

    Video indoor station,e.g. ecoosTM

    Video indoor station,e.g. ecoosTM

    Video indoor station,e.g. ecoosTM

    Power supply