tap-changer vucgde,t - abb group · this document is issued by means of a computerized system. the...

3
This document is issued by means of a computerized syste The digitally stored original is ele ctronically approved approved document has a date entered in the `Approved'-f A manual signature is not required. The information contained in this document has to kept strictly confidential. Any unautorized use, reproduction, distribution or disclosure to third parties are strictly forbidden. ABB reservs all rights regarding Intellectual Property Rights. © Copyright 2010 ABB. All rights reserved. 6917 028-PA(A4)Rev1 255 27 30 50 D 470 600 111 205 C 740 710 220 220 98 6 289 110 739 A B 45 39 80 C/L Top flange 332 60 30 C/L Diverter switch 24x 15 E 110 110 F 55 55 F F C/L Tap selector (3) 1ZSC004163-AAG No. Shts. Document no. 1 16-35 Pos A Sheet no. Order Revision 82 XXXX/700-800/C 2012-04-03 Henrik Sundberg Language Used in product Approved by Tap-Changer VUCGDE,T 2012-03-01 Tomas Axelsson Take over department Modified by PPCO/TK 2011-11-23 Tomas Axelsson Title Responsible department Prepared INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A1931 a)2231 a)1711 a)2011 a) Dimen- sions in mm B 1192 a)1492 a)972 a)1272 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 Positions E F 16-27 18 37 28-35 56 56 14 (Diverter switch terminal) a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capac Please refer to Technical Guide c) Not applicable for 380 kV V-2,4..18 V-2,4..18 H-1,3..17 Same potential as the diverter switch terminal Shielding rings for insulation levels 650, 750 and 1050 only Only for insulation level 1050 kV Transformer flange 650 Contact 5 at 16-19 pos. Contact 7 at 20-31 pos. Contact 9 at 32-35 pos. 21,22 21,22 20 20 Extra contacts: 10 at 18-19 Pos 12 at 22-23 Pos 14 at 26-27 Pos 16 at 30-31 Pos 18 at 32-35 Pos H-1,3..17

Upload: ngotram

Post on 01-Dec-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

255

27

30

50

D

470

600

111 205

C

740

710

220 220

98

6289

110

739

A

B

4539

80 C/L Top flange

332

60

30 C/L Diverter switch

24x 15

E

110

110

F

55

55

F

F

C/L Tap selector

(3)1ZSC004163-AAGNo. Shts.Document no.

116-35 PosA

Sheet no.OrderRevision

82 XXXX/700-800/C2012-04-03Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer VUCGDE,T2012-03-01Tomas Axelsson

Take over departmentModified by

PPCO/TK2011-11-23Tomas Axelsson

TitleResponsible departmentPrepared

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050

A 1931 a)2231 a)1711 a)2011 a)Dimen-sionsin mm

B 1192 a)1492 a)972 a) 1272 a)

C 119 a)c)119 a) 119 a)c)119 a)

D 240 c) 540 240 c) 540

Positions E F

16-27 18 37

28-35 56 56

14 (Diverter switch terminal)

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity.Please refer to Technical Guidec) Not applicable for 380 kV

V-2,4..18

V-2,4..18

H-1,3..17

Same potential as thediverter switch terminal

Shielding rings forinsulation levels 650,750 and 1050 only

Only for insulation level 1050 kV

Transformer flange

650

Contact 5 at 16-19 pos.Contact 7 at 20-31 pos.Contact 9 at 32-35 pos.

21,22

21,2220

20

Extra contacts: 10 at 18-19 Pos 12 at 22-23 Pos 14 at 26-27 Pos 16 at 30-31 Pos 18 at 32-35 Pos

H-1,3..17

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

36�$

72�$

36�$

25,7�$

25,7�$

51,5�$

25,7�$

86

41

R200

232

41

86 84�$

48�$

R200

60�$

60�$

30�$

86

41

86

41

86

41

86

41

36�$

36�$

72�$

60�$

60�$

30�$

25,7�$

25,7�$

51,5�$

25,7�$

(3)1ZSC004163-AAGNo. Shts.Document no.

216-35 PosA

Sheet no.OrderRevision

82 XXXX/700-800/C2012-04-03Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer VUCGDE,T2012-03-01Tomas Axelsson

Take over departmentModified by

PPCO/TK2011-11-23Tomas Axelsson

TitleResponsible departmentPrepared

16-17 positions

P-P

381

6

94 7

2

5

Current collector

Current collector

2010

22

21

P-P

24-25 positions

18

310

9211

4

136

512

7

2014

22

21

20-21 positions

P-P

16

38

510

2012

22

217

92

114

P-P

381

6

94 7

2

510

20

22

21

18-19 positions

P-P

16

38

510

20

22

21712

92

114

22-23 positions

18

310

9211

4

136

512

714

20

22

21

26-27 positions

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

20�$

20�$

40�$

20�$20�$

100

100

45�$

45�$ 22,5�$

45�$

100

100

45�$

45�$ 22,5�$

45�$

20�$

20�$

40�$

20�$20�$

2210

26

11

(3)1ZSC004163-AAGNo. Shts.Document no.

316-35 PosA

Sheet no.OrderRevision

82 XXXX/700-800/C2012-04-03Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer VUCGDE,T2012-03-01Tomas Axelsson

Take over departmentModified by

PPCO/TK2011-11-23Tomas Axelsson

TitleResponsible departmentPrepared

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

P-P

32-33 positions

312 5

14716

11213

4

156

110

178 9

2018

22

21

P-P

28-29 positions

110

158

136

114

92

721

22

20165

14

312

T=9

P-P

110

158

136

114

92

716 21

22

20514

312

30-31 positions

A

P-P

312 5

14 716

11213

4

156

110

178

918

20

22

21

34-35 positions

A