r p p r m - abb group€¦ · this document is issued by means of a computerized system. the...

3
This document is issued by means of a computerized syste The digitally stored original is ele ctronically approved approved document has a date entered in the `Approved'-f A manual signature is not required. The information contained in this document has to kept strictly confidential. Any unautorized use, reproduction, distribution or disclosure to third parties are strictly forbidden. ABB reservs all rights regarding Intellectual Property Rights. © Copyright 2010 ABB. All rights reserved. 6917 028-PA(A4)Rev1 M M R R 255 27 30 50 D 470 600 111 205 C E 195 152 152 152 871 45 126 B 140 225 245 H 490 165 225 165 225 H 8x 1) 18 255 255 98 6 60 390 260 80 C/L Top flange 332 740 24x 15 710 30 C/L Diverter switch 520 165 165 140 A 856 490 P P C/L Tap selector (3) 54920101-5 No. Shts. Document no. 1 5-18 Pos A Sheet no. Order Revision 82 UCGLE,T XXXX/1500/III 2012-04-04 Henrik Sundberg Language Used in product Approved by Tap-Changer UCGL 2012-03-21 Tomas Axelsson Take over department Modified by PPCO/TK 2012-03-09 Tomas Axelsson Title Responsible department Prepared INSULATION380 1050 LEVEL kV 650 750 A 2210 a)2510 a) Dimen- sions in mm B 1354 a)1654 a) C 119 a)c) 119 a) D 240 c) 540 E 30 c) 36 H 580 c) 586 14 Diverter switch terminal T=6 H-2,4..18 V-1,3..17 H-2,4..18 V-1,3..17 1) Holes for mounting of supports for cleats and leads 2) Shielding rings for insulation levels 650, 750 and 1050 only 2) 650 Transformer flange Only for insulation level 1050 kV 18 also at opposite side 1) 2) a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1) c) Not applicable for 380 kV M-M R-R 2x 18 1)

Upload: buidan

Post on 20-Jul-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: R P P R M - ABB Group€¦ · This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

MM

R

R

255

27

30

50

D

470

600

111 205

C

E

195

152152152

871

45

126

B

140

225

245

H

490

165225

165

225

H

8x 1)18

255 255

98

6

60

390

260

80 C/L Top flange

332

740

24x 15

710

30 C/L Diverter switch

520

165 165

140

A

856

490

P P

C/L Tap selector

(3)54920101-5No. Shts.Document no.

15-18 PosA

Sheet no.OrderRevision

82 UCGLE,T XXXX/1500/III2012-04-04Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer UCGL2012-03-21Tomas Axelsson

Take over departmentModified by

PPCO/TK2012-03-09Tomas Axelsson

TitleResponsible departmentPrepared

INSULATION380 1050LEVEL kV 650

750A 2210 a)2510 a)Dimen-

sionsin mm

B 1354 a)1654 a)C 119 a)c)119 a)D 240 c) 540E 30 c) 36H 580 c) 586

14 Diverter switch terminal

T=6

H-2,4..18

V-1,3..17

H-2,4..18

V-1,3..17

1) Holes for mounting of supports for cleats and leads2) Shielding rings for insulation levels 650, 750 and 1050 only

2)

650

Transformer flange

Only for insulation level 1050 kV

18 also at opposite side 1)

2)

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)c) Not applicable for 380 kV

M-M

R-R2x 18 1)

Page 2: R P P R M - ABB Group€¦ · This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

20�$

20�$

100�$

40�$20�$

20�$

100�$

40�$20�$

20�$

100�$

40�$20�$

20�$

60�$

40�$20�$

20�$

20�$

40�$

15

40

13

R282.5

(3)54920101-5No. Shts.Document no.

25-18 PosA

Sheet no.OrderRevision

82 UCGLE,T XXXX/1500/III2012-04-04Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer UCGL2012-03-21Tomas Axelsson

Take over departmentModified by

PPCO/TK2012-03-09Tomas Axelsson

TitleResponsible departmentPrepared

T=14

5 and 6 positions

P-P

12

34

56

Current collectors

7 and 8 positions

P-P

12

34

56

78

P-P

9 and 10 positions

12

34

56

789

10A

P-P

11 and 12 positions

12 3

4

56

78

910

1112

P-P

13 and 14 positions

12

34 5

6

78

910

1112

1314

A

Page 3: R P P R M - ABB Group€¦ · This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

The information contained in this document has to kept strictly

confidential. Any unautorized use, reproduction, distribution

or disclosure to third parties are strictly forbidden.

ABB reservs all rights regarding Intellectual Property Rights.

© Copyright 2010 ABB. All rights reserved.

6917 028-PA(A4)Rev1

20�$

20�$

20�$

40�$

20�$

20�$

20�$

40�$

(3)54920101-5No. Shts.Document no.

35-18 PosA

Sheet no.OrderRevision

82 UCGLE,T XXXX/1500/III2012-04-04Henrik Sundberg

LanguageUsed in productApproved by

Tap-Changer UCGL2012-03-21Tomas Axelsson

Take over departmentModified by

PPCO/TK2012-03-09Tomas Axelsson

TitleResponsible departmentPrepared

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL:54830001-1Motor Drive BUE:54830001-2 or -3External Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1

12

34 5

6

78

910

111213

14

1516

12

345

6

78

910

1112

1314 15

16

1718

P-P

15 and 16 positions

P-P

17 and 18 positions