syringe catalog - chromspec series and family definitions see more on page 4 neuroscience animal...

52
The Measure of Excellence ® for your application Syringe Catalog

Upload: vunguyet

Post on 16-Mar-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

The Measure of Excellence® for your application

Syringe Catalog

Page 2: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Hamilton syringes are the finest quality precision fluid measuring devices

available. Top quality materials and skilled workmanship ensure that Hamilton

syringes consistently deliver the highest possible performance for reliable

analyses. For manual uses, our syringes are accurate to within ± 1% of the

nominal volume with a precision of 1% at 80% of the total volume.

Hamilton offers the most complete selection of syringes on the market for

use in various applications including gas chromatography (GC) and high

performance liquid chromatography (HPLC), liquid handling and life sciences.

The present catalog is a tool to help you select the appropriate syringe for your

application. It also provides detailed background and technical information to

help you understand the full functionalities and possibilities for your syringes.

Products manufactured by Hamilton Company are intended for scientific research and laboratory use only and are not intended for human in vivo use.

Unsurpassed Accuracy and Precision

A New Application-Based Catalog

Find the Perfect Syringe OnlineIf you do not find the correct syringe to meet your needs in this catalog, please consult Hamilton’s online syringe selection tool at www.hamiltoncompany.com/syringes or contact customer support using the information on the back of the catalog.

Page 3: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Syringe series and family definitionsSee more on page 4

Neuroscience animal injectionsSee more on page 30

HPLC autosampler syringesSee more on page 20

For more information on the full portfolio of Hamilton syringes, needles and accessories or to order a product, please visit www.hamiltoncompany.com or refer to the back of this catalog for additional contact details.

Table of ContentsFind the Perfect Syringe Online ..............................................2Technical Syringe Information ..................................2

Syringe Technical Illustrations .................................................2Syringe Series ........................................................................4Syringe Terminations ..............................................................4Needle Point Styles ................................................................4

Gas Chromatography Syringes ................................5

Manual Split/Splitless Injection ...............................................6Manual On-Column Injection ................................................10Gas Chromatography Autosampler Syringes ........................ 11

Liquid Chromatography Syringes ..........................16

HPLC Syringes .....................................................................16Thin Layer Chromatography .................................................19HPLC Autosampler Syringes ................................................20

Sample Preparation and Liquid Handling .............26

Syringes For the Hamilton Microlab 600 ...............................27Syringes For Laboratory Syringe Pumps ..............................27Tubing Assemblies ...............................................................27

Life Science Syringes ..............................................29

General Animal Injections .....................................................29Neuroscience Injections .......................................................30Genomics and Biochemistry ................................................34

Product Listing by Features ....................................36

Microliter Syringes ................................................................36Gastight Syringes .................................................................38Needles ................................................................................40

Syringe Care and Use ..............................................44

Part Number Index ...................................................47

About Hamilton Company .......................................49

1

Page 4: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Technical Syringe InformationMicroliter™ Syringes (700 Series)

Microliter syringes are used with liquid only. They feature a stainless steel plunger which is individually fitted to the glass barrel. The result is a liquid tight seal with nearly frictionless movement. These syringes are ideal for organic samples that are not prone to precipitation, crystallization or bonding with glass.

Modified Microliter Syringes (7000 Series)

These syringes are designed to dispense volumes below 5 µL. This requires an extremely small tungsten plunger wire that travels to the tip of the needle. The resulting design has zero dead volume and is accurate below 50 nL.

Fitted plungerBarrel with graduationsNeedle gauge

Point style Termination Flange

Plunger travels inside the needle through to the tip

Tightening the nut applies force to the ferrule

The PTFE ferrule presses into the Knurled Hub to create a seal around the plunger wire

The black sleeve indicates volume and protects the plunger wire

TECHNICAL SYRINGE INFORMATION

Page 5: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gastight® Syringes (1700 and 1000 Series)

Gastight syringes are ideal for dispensing both liquids and gases. They have a polymer plunger tip which creates a leak-free seal. Traditionally the tip is made from PTFE but other materials are used for selected applications. The polymer tip essentially wipes the interior of the syringe barrel free of sample. This feature is useful for aqueous and low volatile organic samples because it reduces the chance a deposit will occur and result in cross-contamination or even a damaged plunger.

Reinforced Plunger Syringes (800 and 1800 Series)

Small volume syringes require extremely small plunger wires. For uses that are prone to bending and breaking these small plungers, it is recommended to use a reinforced plunger syringe. These plungers are available in both Microliter and Gastight versions.

Plunger wire Protective sleeve Friction nut applies pressure to the ferrule which grips the plunger wire and creates resistance

Reinforced plunger adapter

Polymer tip creates a leak-free seal for both liquids and gases

3

TECHNICAL SYRINGE INFORMATION

Page 6: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Syringe Series

Syringe Terminations

Needle Point Styles

Syringe Series Volume Syringe Type Plunger Type

7000 0.5 μL – 5 μL Modified Microliter Tungsten plunger

700 5 μL – 500 μL Microliter Stainless steel fitted plunger

800 5 μL – 250 μL Microliter Reinforced stainless steel fitted plunger

1700 10 μL – 500 μL Gastight Polymer tipped plunger

1800 10 μL – 250 μL Gastight Reinforced polymer tipped plunger

1000 1 mL – 100 mL Gastight Polymer tipped plunger

Super Syringe 0.5 L – 2 L Gastight Plunger with polymer tip with Buna-N seal

Termination Abbreviation Remark Autoclavable

Cemented Needle N For low-volume syringes No

Luer Tip Cemented Needle

LTN For mid-volume syringes No

Removable Needle RN Yes if disassembled

Knurled Hub KHFor Modified Microliter syringes only

Yes if disassembled

Luer Tip LT Yes if disassembled

PTFE Luer Lock TLL Yes if disassembled

SampleLock™ SL Integrated on/off valve No

Fixed Needle FNFound on CTC C-Line and X-Type syringes

No

Cheminert® C1/4"–28 UNF/threaded connection

No

Point Style Description Application

210-12° sharp, beveled, curved non-coring

Gas chromatography, septum piercing

3 Blunt, electro-polishedHigh performance liquid chromatography (HPLC) injection, thin layer chromatography (TLC), general liquid handling, controlled animal injections

3TBlunt, electro-polished, coated with PTFE 19 mm from the tip

Thin layer chromatography (TLC) applications

4 Sharp 10-12° beveled needle Life science/animal injections

5Conical with side port for penetration without coring

Headspace, applications prone to needle clogging, causes minimal septum damage

ASConical, non-coring designed to withstand multiple injections

Autosampler injection, pre-pierced septa

TECHNICAL SYRINGE INFORMATION

Page 7: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gas Chromatography SyringesThe invention of the Microliter syringe by Clark Hamilton in 1947 enabled the development of gas chromatography. “At that time there was no convenient way to introduce microliter (or even smaller) volumes of liquids into a gas chromatograph,” wrote Professor Georges Guiochon, Professor and Distinguished Scientist at University of Tennessee. “In fact, it is not an exaggeration to say that without the Hamilton syringes, gas chromatography could not have become everybody’s technique” [Chromatographia 15(6), 333 (1982)]. Injection into a gas chromatograph may be manual or automatic. In both cases, a microsyringe is required to introduce the sample. The choice of the correct syringe depends on the type of injector used.

5

GAS CHROMATOGRAPHY SYRINGES

Page 8: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Manual Split/Splitless InjectionA split/splitless injector consists of a heated chamber with a glass liner into which the sample is injected through the septum. A microsyringe is used to inject the sample through a rubber septum into a flash vaporizer chamber at the head of the column. The sample vaporizes to form a mixture of carrier gas, vaporized solvent and vaporized analytes. In the split mode, only a proportion of this mixture reaches the column but most exits through the split outlet. This avoids overloading the column. In the splitless mode, the split vent is closed so that the vaporized analyte passes onto the column. This mode is more sensitive and adequate for trace analysis.

Common syringe features for split/splitless injection include:XXXXXX Microliter syringes for liquid samples and Gastight

syringes for gas and liquid samples

XXXXXX Common volume range between 0.5 μL to 50 μL

XXXXXX Needle with point style 2 to pierce the rubber septum

XXXXXX Needle length of 51 mm to reach the middle of the glass liner. Splitless injection of small volumes may be performed with a 70 mm needle to deposit the sample close to the column entrance.

Syringe

Septum

Septum purge outlet

Glass liner

Split outlet

Heated injector block

Capillary column

Needle

Carrier gas inlet

Vaporisation chamber

Illustration of a split/splitless injector

GAS CHROMATOGRAPHY SYRINGES

Page 9: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Syringes For Manual Injection of Liquid Samples

Volume

Model

Gauge

0.5 μL

7000.5

25

1.0 μL

7001

25

2.0 μL

7002

25

5.0 μL

7105

24

Knurled Hub (KH) Syringe (point style 2) 86259 80135 88411 88011

Standard Injection Spacer (25 mm) 86201 86201 86201 86201

Note: Needles are 70 mm

Zero Dead Volume Syringes

Injection of Liquid Samples

Volume

Model

Gauge

5 μL

75

26s

10 μL

701

26s

25 μL

702

22s

50 μL

705

22s

100 μL

710

22s

250 μL

725

22s

500 μL

750

22

Cemented Needle (N) Syringe (point style 2)

8790080300 80366 (6 pk)

80400 80500 80600 80700 80800

Removable Needle (RN) Syringe (point style 2)

8793080330 80336 (6 pk)

80430 80530 80630 80730 80830

Replacement Needle 6 pk (point style 2)

7758-02 7758-02 7758-03 7758-03 7758-03 7779-03 7779-01

Note: Needles are 51 mm

Tech TipChoose a

syringe with a removable needle if working with halogenated solvents.

7

GAS CHROMATOGRAPHY SYRINGES

Page 10: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Reinforced Plunger Syringes

Volume

Model

Gauge

10 μL

1801

26s

25 μL

1802

22s

50 μL

1805

22s

100 μL

1810

22s

250 μL

1825

22s

Removable Needle (RN) Syringe (point style 2)

84877 84880 84883 84886 84889

Replacement Needle, 6 pk (point style 2) 7758-02 7758-03 7758-03 7758-03 7779-03

Note: Needles are 51 mm

Syringes For Manual Injection of Gas and Liquid Samples

Injection of Gas and Liquid Samples

Volume

Model

Gauge

10 μL

1701

26s

25 μL

1702

22s

50 μL

1705

22s

100 μL

1710

22s

250 μL

1725

22s

Cemented Needle (N) Syringe (point style 2) 80000 80200 80900 81000

Cemented Needle (LTN) Syringe (point style 2) 81100

Removable Needle (RN) Syringe (point style 2) 80030 80230 80930 81030 81130

Replacement Needle 6 pk (point style 2) 7758-02 7758-03 7758-03 7758-03 7779-03

Volume

Model

Gauge

500 μL

1750

22

1000 μL

1001

22

2500 μL

1002

22

5000 μL

1005

22

10000 μL

1010

22

Cemented Needle (LTN) Syringe (point style 2) 81217 81317 81417 81517 81617

Removable Needle (RN) Syringe (point style 2) 81230 81330 81430 81530 81630

Replacement Needle 6 pk (point style 2) 7779-01 7779-01 7779-01 7779-01 7779-01

Note: Needles are 51 mm

Reinforced Plunger Syringe

GAS CHROMATOGRAPHY SYRINGES

Page 11: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Volume

Model

10 μL

701/1701

25 μL

702/1702

50 μL

705/1705

100 μL

710/1710

250 μL

725/1725

500 μL

750/1750

Reproducibility (Chaney) Adapter 14700 14725 14725 14725 14725 14725

Adapter For Repeated Manual Injection

Tech TipImprove the

reproducibility of multiple manual injections with the Chaney Adapter (p/n 14700 and 14725).Chaney Adapter

9

GAS CHROMATOGRAPHY SYRINGES

Page 12: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

XXXXXX Small outer diameter needles adjusted to the inner diameter of the column (0.17 mm needle for columns with 0.25 mm inner diameter, 32 gauge for columns with 0.32 mm inner diameter, and 26 gauge for columns with a 0.53 mm inner diameter)

XXXXXX Longer needles tailored to pass through the injector and reach within the capillary column

XXXXXX Point style 3 adapted to the typical septum of the on-column injector

XXXXXX Small volume of 5 μL or 10 μL

Syringes for On-Column Injection For Capillary Columns

Manual On-Column InjectionOn-column injection employs the direct introduction of the liquid sample into the column. This is very useful for the analysis of thermally unstable samples and avoids boiling point discrimination. On-column injection requires special syringes with the following features:

Syringe

Septum

Heated injector block

Capillary column

Needle

Carrier gas inlet

Illustration of an on-column injector

Volume

Model

Gauge

Column I.D.

10 µL

701

0.17 mm

0.25 mm

10 µL

701

32

0.32 mm

10 µL

701

26s

0.53 mm

Fused Silica Needle Syringe (point style 3)

874021 803082 803082

Note: Needles are 100 mm 1) This is an RN needle2) These are stainless steel needles. Please specify gauge, length and point style.

GAS CHROMATOGRAPHY SYRINGES

Page 13: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gas Chromatography Autosampler SyringesAutosamplers enable the automatic introduction of samples into the injector of the gas chromatograph (GC). Automatic injection has become very common as it improves reproducibility and speed.

Hamilton offers a wide range of autosampler syringes. The features of the autosampler syringes are adapted for an exact fit to a specific autosampler. The point style AS (for autosampler) has been specifically designed to withstand repeated penetration through the GC autosampler septa. Syringes for headspace injection usually have a point style 5, which is ideal for large gas volume injection. Autosampler syringes are available in two gauge types depending on the type of injector used.

Gauge Application

23sDurable needle for Merlin MicroSeal™ septa and split/splitless injections

26sVersatile needle for all types of injections including split/splitless and on-column injections

For a full list of all syringes available, visit www.hamiltoncompany.com/syringes

CTC Autosampler

11

GAS CHROMATOGRAPHY SYRINGES

Page 14: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

C-Line Syringes

C-Line syringes incorporate several unique design features that ensure superior performance. The innovative direct attachment design of the needle to the barrel eliminates contact between the sample solvent and adhesive, reducing carryover and ghost peaks. The inert plunger tip polymer provides enhanced solvent compatibility and longer lifetime.

Headspace Syringes for CTC PAL® Combi-xt

Modern GC headspace analysis requires injecting over large temperature ranges. Conventional headspace syringes on the market use a rubber O-ring sealed plunger which has a limited sealing performance at high temperatures due to varying thermal expansion between the different materials. The high dynamic HD-type syringe employs a unique spring in the plunger tip which compensates for the materials’ different expansion coefficients, creating a better seal over a larger temperature range, and it also improves lifetime.

C-Line PAL® COMBI-xt and PAL GC-xt Liquid Injection Syringes

PAL® COMBI-xt Headspace Syringes

CTC PAL® COMBI-xt and PAL® GC-xt Autosampler Syringes

Volume

Model

Gauge

1.2 µL

7701.2

26

5 µL

75

26s

10 µL

701

26s

25 µL

1702

26s

100 µL

1710

26s

250 µL

1725

26

500 µL

1750

26

Fixed Needle (FN) Syringe (point style AS)

2031851 203189203205 2033612 203043 2030763 203078 203080

Note: Needles are 51 mm1) KH Termination2) 23s gauge3) Slimline syringe

Volume

Model

Gauge

1000 µL

1001

26

1000 µL

1001

23

2500 µL

1002

26

2500 µL

1002

23

5000 µL

1005

26

5000 µL

1005

23

Cemented Needle (LTN) Syringe (point style 5)

2031411 2030821 203181 203084 203182 203086

Note: Needles are 51 mm1) FN termination

CTC PAL® autosamplers are one of the most popular sampling devices on the market today for GC and headspace analyses. Customers rely on its ability to sample from many different vial and well types and on its ultimate platform flexibility. The syringe is at the heart of every injection that the GC PAL® system performs and CTC chose Hamilton to provide this critical component.

GAS CHROMATOGRAPHY SYRINGES

Page 15: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Agilent 7693 Autosampler

Agilent 7673, 7683, 7693 and 6850 Autosampler Syringes

Durable Syringes For Merlin Microseal™ Septa and Split/Splitless Injection

Universal Syringes For Split/Splitless and On-Column Injection

Versatile Syringes For All Types of Injections, Including On-Column Injection

Volume

Model

Gauge

0.5 µL

7000.5

23

1 µL

7001

23

5 µL

75

23s

10 µL

701

23s

10 µL

1701

23s

Cemented Needle (N) Syringe (point style AS)

87987 87990 (6 pk)

80387 80390 (6 pk)

80080 80094 (6 pk)

Knurled Hub (KH) Syringe (point style AS)

86276 80176

Note: Needles are 43 mm

Volume

Model

Gauge

5 µL

75

23s–26s

10 µL

701

23s–26s

10 µL

1701

23s–26s

Cemented Needle (N) Syringe (point style AS)

87993 87994 (6 pk)

80393 80391 (6 pk)

80079 80096 (6 pk)

Note: Needles are 43 mm

Volume

Model

Gauge

0.5 µL

7000.5

26

5 µL

75

26s

10 µL

701

26s

Cemented Needle (N) Syringe (point style AS)

862741 87988 87989 (6 pk)

80388 80389 (6 pk)

Note: Needles are 43 mm1) KH termination

13

GAS CHROMATOGRAPHY SYRINGES

Page 16: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Thermo Scientific® Autosampler Syringes

Volume

Model

Gauge

10 μL

701

26s

Cemented Needle (N) Syringe (point style AS)

80318

Note: Needles are 80 mm

AS 800, AS 2000 Syringes Headspace HS 250/500/850 Syringes

AI/AS 3000 Tri Plus Syringes

Varian-Chrompack Autosampler Syringes

Varian CP 8400/8410 CP9019/9050 Syringes

Varian 8100/8200 SyringesVarian-Chrompack 8400 Autosampler

Volume

Model

Gauge

5 µL

75

26s

10 µL

701

26s

Cemented Needle (N) Syringe (point style 2)

87900 80300

Cemented Needle (N) Syringe 6 pk (point style 2)

80366

Note: Needles are 51 mm

Volume

Model

Gauge

5 µL

75

26s

10 µL

701

26s

Cemented Needle (N) Syringe (point style AS)

204051 204052

Cemented Needle (N) Syringe (point style 2)

204000 204001

Note: Needles are 50 mm

Volume

Model

Gauge

2500 μL

1002

22

Cemented Needle (LTN) Syringe (point style 5)

202660

Note: Needles are 56 mm

Volume

Model

Gauge

10 µL

701

0.48 mm

Removable Needle (RN) Syringe (point style 5)

202880

Note: Needles are 50.5 mm

Thermo Scientific® Finnigan AS 2000 Autosampler

GAS CHROMATOGRAPHY SYRINGES

Page 17: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Shimadzu Autosampler Syringes

Shimadzu AOC-9 Syringes

Shimadzu AOC-14/AOC-17/AOC-20 Syringes

Shimadzu AOC-14 Autosampler

Volume

Model

Gauge

5 µL

75

26s

10 µL

701

26s

Removable Needle (RN) Syringe (point style 2)

87930 80330

Note: Needles are 51 mm

Volume

Model

Gauge

5 µL

75

22s

10 µL

701

22s

Removable Needle (RN) Syringe (point style 2)

202630 202640

Note: Needles are 43 mm

15

GAS CHROMATOGRAPHY SYRINGES

Page 18: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Liquid Chromatography SyringesHamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes.

HPLC SyringesHPLC syringes are especially designed for manual or automatic injection within high pressure ports. The needle is blunt and electro-polished to slide smoothly into the injection port reducing the wear on critical seals. The selection of the appropriate syringe for HPLC applications takes the following three aspects into account: the type of injection valve, the sample properties and the injection volume. The volume of the syringe should be adjusted to the volume of the injection. In partial loop filling, the injection volume should not be greater than half of the loop capacity. In complete loop filling, where the loop size sets the injection volume, the syringe capacity should be greater than twice the loop volume.X

LIQUID CHROMATOGRAPHY SYRINGES

Page 19: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Rheodyne®, Valco®, Beckman Coulter, Altex and SSI Injection Valve Syringes

Gastight Syringes For Aqueous Samples

Microliter Syringes For Volatile Organic Samples

Volume

Model

Gauge

10 µL

701

22s

25 µL

702

22s

50 µL

705

22s

100 µL

710

22s

250 µL

725

22

500 µL

750

22

Cemented Needle (N) Syringe (point style 3)

80365 80465 80565 80665 80765 80865

Note: Needles are 51 mm

Volume

Model

Gauge

10 µL

1701

22s

25 µL

1702

22s

50 µL

1705

22s

100 µL

1710

22s

250 µL

1725

22s

500 µL

1750

22

1000 µL

1001

22

Cemented Needle (N) Syringe (point style 3)

80275 80975 81075

Cemented Needle (LTN) Syringe (point style 3)

81175 81216 81316

Removable Needle (RN) Syringe (point style 3)

80065 80265 80965 81065 811651 81265 81365

Replacement Needle 6 pk (point style 3)

7770-01 7770-01 7770-01 7770-01 7780-03 7780-04 7780-04

Note: Needles are 51 mm1) 22 gauge needle

Tech TipGastight syringes have a polymer tipped

plunger, often PTFE, which essentially wipes the interior of the syringe barrels. This reduces the risk of deposition on the barrel which may cause cross-contamination or plunger seizing.

17

LIQUID CHROMATOGRAPHY SYRINGES

Page 20: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Valco® VISF-1 Injection Valve Syringes

Valco® VISF-1 Valve Syringes

Adapter For Repeated Manual Injection

Hamilton was the first to offer pressure-stable HPLC columns, and the company now features a wide range of column retention selectivities and performance benefits. Hamilton offers 19 different polymer-based HPLC columns for reversed phase, anion exchange, cation exchange and ion exclusion separations. Hamilton’s polymeric HPLC columns combine the inertness and pH stability of polymeric supports with the pressure stability and durability of silica-based columns. Two silica-based C8 and C18 columns are also available for reversed phase separations.

The Power of Polymeric HPLC Columns

Volume

Model

10 µL

701/1701

25 µL

702/1702

50 µL

705/1705

100 µL

710/1710

250 µL

725/1725

500 µL

750/1750

Reproducibility (Chaney) Adapter

14700 14725 14725 14725 14725 14725

Volume

Model

Gauge

25 µL

1702

22s

50 µL

1705

22s

100 µL

1710

22s

250 µL

1725

22s

500 µL

1750

22

1000 µL

1001

22

Removable Needle (RN) Syringe (point style 3)

80231 80931 81031 81131 81231 81331

Replacement Needle 6 pk (point style 3)

7787-01 7787-01 7787-01 7806-021 7787-02 7787-02

Note: Needles are 19 mm1) Please specify length and point style

Tech TipImprove the

reproducibility of multiple manual injections with the Chaney adapter (p/n 14700 and 14725).

LIQUID CHROMATOGRAPHY SYRINGES

Page 21: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Thin Layer ChromatographyThe point of the needle of a thin layer chromatography (TLC) syringe is covered with a PTFE coating (point style 3T). The coating reduces the surface tension between the needle and the liquid making it ideal for reproducible sample spotting.

Thin Layer Chromatography Syringes

Volume

Model

Gauge

10 µL

1701

26s

25 µL

1702

22s

50 µL

1705

22

100 µL

1710

22

Cemented Needle (N) Syringe (point style 3T)

80050 80250 80950 81050

Note: Needles are 51 mm

For a full list of all syringes available, visit www.hamiltoncompany.com/syringes

19

LIQUID CHROMATOGRAPHY SYRINGES

Page 22: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

HPLC Autosampler SyringesHPLC autosamplers enable the automatic introduction of samples into the sample loop as well as a certain amount of sample preparation. Automatic injection has become very common, as it provides improved reproducibility and speed. Hamilton offers a wide range of HPLC autosampler syringes. The features of the autosampler syringes are adapted for an exact fit to a specific autosampler.

CTC PAL® HTC-xt, HTS-xt and HTX-xt Autosampler SyringesCTC PAL® autosamplers are one of the most popular sample processing systems for HPLC analyses. Customers rely on its ability to sample from many different vial and well types and on its ultimate platform flexibility. The syringe is at the heart of every injection that the LC PAL® system performs and CTC chose Hamilton to provide this critical component.

LIQUID CHROMATOGRAPHY SYRINGES

Page 23: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

C-Line Syringes

C-Line syringes incorporate several unique design features that ensure superior performance. The innovative direct attachment design of the needle to the barrel eliminates contact between the sample solvent and adhesive reducing carryover and ghost peaks. The inert plunger tip polymer provides enhanced solvent compatibility and longer lifetime.

C-Line CTC PAL® HTC-xt, HTS-xt and HTX-xt Syringes

Volume

Model

Gauge

10 µL

1701

22s

25 µL

1702

22s

100 µL

1710

22s

250 µL

1725

22

500 µL

1750

22

1000 µL

1001

22

2500 µL

1002

22

5000 µL

1005

22

Fixed Needle (FN) Syringe (point style 3)

2031942 203075 2030771 203079 203349 2030811 2030831 2030851

Note: Needles are 51 mm1) LTN termination2) Slimline syringe

X-Type Syringes For Sensitive Chromatography Applications

X-Type Syringes

Hamilton, together with CTC Analytics, has developed X-Type syringes with near zero carryover and a long-lasting plunger tip to meet the requirement of high-throughput life science analytical syringes for sensitive applications. The syringe glass barrel is polished and sealed for inertness and enhanced lifetime. The needle is deactivated to reduce sample adsorption. Tests with critical samples like phospholipids, basic molecules and peptides have shown that carryover and absorption can be reduced depending on the sample. The plunger’s life cycle is also improved.

Volume

Model

Gauge

25 µL

1702

22s

50 µL

1705

22s

100 µL

1710

22

100 µL

1710

22s

Fixed Needle (FN) Syringe (point style 3)

204475 204379 204400 204452

Note: Needles are 51 mm

A guide to syringe terminations and needle points can be found on page 4.

21

LIQUID CHROMATOGRAPHY SYRINGES

Page 24: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

LIQUID CHROMATOGRAPHY SYRINGES

Page 25: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Agilent/Varian Autosampler Syringes

Agilent 1290 Infinity LC Injector HTC/HTS Syringes

Varian Prostar 410/420/430 Syringes

Thermo Scientific® Autosampler Syringes

AS 100/300 and AS 1000/3000/3500 Syringes

SP 8780/8875/8880 Syringes

Thermo Scientific® AS 3000 Autosampler

Spark Holland Midas Autosampler

Volume

Model

Gauge

10 µL

1701

22s

25 µL

1702

22s

100 µL

1710

22s

250 µL

1725

22

500 µL

1750

22

1000 µL

1001

22

2500 µL

1002

22

5000 µL

1005

22

Fixed Needle (FN) Syringe (point style 3)

2031941 203075 2030771 203079 203349 2030812 2030832 2030852

Note: Needles are 51 mm1) Slimline syringe2) LTN termination

Volume

Model

Gauge

250 µL

1725

No needle

2500 µL

1002

No needle

Cheminert® (C) Syringe

202145 81460

Volume

Model

Gauge

250 µL

1725

No needle

500 µL

1750

No needle

1000 µL

1001

No needle

2500 µL

1002

No needle

5000 µL

1005

No needle

Cheminert® (C) Syringe

202145 202192 81360 81460 81560

Volume

Model

Gauge

25 µL

1702

No needle

100 µL

1710

No needle

250 µL

1725

No needle

500 µL

1750

No needle

1000 µL

1001

No needle

2500 µL

1002

No needle

Cheminert® (C) Syringe

62161-01 54658-01 54659-01 54660-01 54661-01 54662-01

23

LIQUID CHROMATOGRAPHY SYRINGES

Page 26: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Spark Holland Autosampler Syringes

The Hamilton Spark Holland syringe line works with the following manufacturers’ autosamplers:

XXXXXX Spark Holland Midas, Triathlon, Endurance and Alias

XXXXXX Antec AS 100 and AS 110

XXXXXX Dionex ESA Model 542, 540 and 540MT

XXXXXX Beckman Coulter 508

XXXXXX Grace/Alltech Model 580

Spark Holland Endurance Autosampler

Waters® Autosampler Syringes

Waters® 2777 Sample Manager SyringesWaters® 2777 Sample Manager

Waters® 2707 Autosampler Syringes

Volume

Model

Gauge

25 µL

1702

No needle

100 µL

1710

No needle

250 µL

1725

No needle

500 µL

1750

No needle

1000 µL

1001

No needle

2500 µL

1002

No needle

Cheminert® (C) Syringe

62161-01 54658-01 54659-01 54660-01 54661-01 54662-01

Spark Holland Autosampler Syringes

Volume

Model

Gauge

10 µL

1701

22s

25 µL

1702

22s

100 µL

1710

22s

250 µL

1725

22

500 µL

1750

22

1000 µL

1001

22

2500 µL

1002

22

5000 µL

1005

22

Fixed Needle (FN) Syringe (point style 3)

2031941 203075 2030771 203079 203349 2030812 2030832 2030852

Note: Needles are 51 mm1) Slimline syringes2) LTN termination

Volume

Model

Gauge

25 µL

1702

No needle

100 µL

1710

No needle

250 µL

1725

No needle

500 µL

1750

No needle

1000 µL

1001

No needle

2500 µL

1002

No needle

Cheminert® (C) Syringe 62161-01 54658-01 54659-01 54660-01 54661-01 54662-01

LIQUID CHROMATOGRAPHY SYRINGES

Page 27: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

PerkinElmer® Autosampler Syringes

Series 225, Flexar® FX-10/FX-15 Syringes

Series 200 Syringes

Volume

Model

Gauge

50 µL

1705

No needle

250 µL

1725

No needle

500 µL

1750

No needle

1000 µL

1001

No needle

2500 µL

1002

No needle

Cheminert® (C) Syringe

80962 81162 81262 81360 81460

PerkinElmer® Series 225 Autosampler

Volume

Model

Gauge

25 µL

1702

No needle

100 µL

1710

No needle

250 µL

1725

No needle

500 µL

1750

No needle

1000 µL

1001

No needle

2500 µL

1002

No needle

Cheminert® (C) Syringe 62161-01 54658-01 54659-01 54660-01 54661-01 54662-01

25

LIQUID CHROMATOGRAPHY SYRINGES

Page 28: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Sample Preparation and

Syringe pumps are the most accurate and precise tool for liquid handling. For any syringe pump, the key in achieving the most accurate dispenses is the syringe. Hamilton has a 40-year proven history of designing and manufacturing syringe pumps. With the recent launch of the Microlab® 600, Hamilton’s innovation has been brought a step further. The new generation of semi-automated diluters and dispensers are designed for ease of use thanks to the full-color touchscreen interface. The Microlab 600 is used in analytical laboratories performing sample dilution and aliquoting in fields such as pharmaceutical, mining or environmental analysis.

Liquid Handling

SAMPLE PREPARATION AND LIQUID HANDLING

Page 29: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Microlab 600 Syringes

Volume 10 μL 25 μL 50 μL 100 μL 250 μL 500 μL

Bubble Free Prime Syringe 59000-05 59000-10 59000-15 59000-20 59000-25 59000-30

Volume 1 mL 2.5 mL 5 mL 10 mL 25 mL 50 mL

Bubble Free Prime Syringe 59000-35 59000-40 59000-45 59000-50 59000-55 59000-60

SaltLine™ Syringe 208335 208336 208337

Laboratory Syringe Pump Syringes

Volume

Model

50 μL

1705

100 μL

1710

250 μL

1725

500 μL

1750

1 mL

1001

2.5 mL

1002

Luer Lock (TLL) Syringe 80920 81020 81120 81220 81320 81420

SaltLine Luer Lock (TLL) Syringe 203220 203230 203240 203250

Volume

Model

5 mL

1005

10 mL

1010

25 mL

1025

50 mL

1050

100 mL

1100

Luer Lock (TLL) Syringe 81520 81620 82520 85020 86020

SaltLine Luer Lock (TLL) Syringe 203260 203270

Syringes For Laboratory Syringe Pumps

Laboratory syringe pumps, which may be manufactured by companies such as Harvard Apparatus, KD Scientific, Inc., Kent Scientific Corporation, cetoni and others, are common for microfluidics, drug/nutritional infusions, electrospinning, mass spectrometer calibration, cell feeding and many other applications. There are several infusion pump manufacturers, but one thing is consistent—when a precise flow is critical, all manufacturers turn to Hamilton syringes. Our syringes are available in volumes from 0.5 µL to 100 mL and a variety of terminations to serve almost any application. The PTFE Luer Lock (TLL) termination is extremely common as it provides the most flexible options for connection of tubing.

Hub

Length

Material

No hub

Custom

PTFE

1x Female Luer

Custom

PTFE

1x Female Luer

300 mm

PTFE

Gauge 12 20912 90662 90612

Gauge 18 20918 90668 90618

Gauge 22 20922 90672 90622

Gauge 30 20930 90680 90630

Tubing Assemblies For Luer Lock and Luer Tip Syringes

Syringes For the Hamilton Microlab 600

27

SAMPLE PREPARATION AND LIQUID HANDLING

Page 30: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

The Microlab 600 is a highly precise syringe pump that specializes in tasks too small to automate but too large to reliably accomplish by hand, making it invaluable to labs looking to increase efficiency and consistency while reducing cost and wasted buffer. It uses a positive displacement system to provide better than 99% accuracy, independent of a liquid’s viscosity, vapor pressure, and temperature – even with harsh chemicals.

With its simple touchscreen interface, built-in wizards and custom method tool, it helps every laboratory work smarter. The free compliance software package on Advanced models features enhanced security options that adhere to CFR 21 Part 11 and FDA GMP/GLP requirements.

Automate Your Handheld Pipetting

Tech TipSaltLine

syringes have a highly inert and non-corrosive plunger as well as a particularly resistant ultra-high molecular weight poly-ethylene (UHMWPE) plunger tip, which considerably enhances the syringe lifetime with salt and acid solutions. SaltLine syringes are recommended for life science applications with salty buffers, mining applications with acids or trace metal analysis.

For more information on the Microlab 600 benefits your lab, visit www.hamiltoncompany.com/microlab600

SAMPLE PREPARATION AND LIQUID HANDLING

Page 31: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Hamilton Company offers a wide variety of specialized syringes for life science applications. From custom needles to specialized animal injections and gel loading syringes, Hamilton has a solution for your precision liquid handling life science applications.

Life Science Syringes

Custom Stainless Steel Needles

Gauge

O.D. X I.D. (mm)

27

0.41 x 0.21

28

0.36 x 0.18

29

0.34 x 0.18

30

0.31 x 0.16

31

0.26 x 0.13

32

0.24 x 0.11

33

0.21 x 0.11

34

0.16 x 0.05

Small RN Needle

7803-01 7803-02 7803-06 7803-07 7803-03 7803-04 7803-05 2074341

Note: Please specify length and point style when ordering1) This needle should be used with a Gastight syringe

General Animal InjectionsHamilton features a selection of small volume syringes and small gauge needles that can be used for performing injections on lab animals.

Small Hub Removable Needle Syringes and Custom Needles

Animal injections require a variety of different needle lengths and gauges depending on the target of the injection. For this purpose, Hamilton provides a variety of custom needle options between 27 and 34 gauge. These needles are combined with our small volume Removable Needle syringes to create the perfect application specific syringe. The most common point style for animal injection is point style 4 which comes standard with a sharp 12° beveled tip. If the vessel you are targeting is extremely small, it is possible to select a custom bevel between 12° and 60° to best suit the application. If a blunt point is desired, select point style 3. To minimize needle flexing it is recommended to choose the shortest length possible. The ideal length is typically 13 mm and shorter.

General Animal Injection Syringes

Volume

Model

5 µL

75

10 µL

1701

25 µL

1702

50 µL

1705

100 µL

1710

Removable Needle (RN) Syringe (no needle included)

7634-01 7653-01 7654-01 7655-01 7656-01

For a full list of all syringes available, visit www.hamiltoncompany.com/syringes

29

LIFE SCIENCE SYRINGES

Page 32: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Neuros Syringes

Neuroscience InjectionsIntroducing Neuros™ Syringes

Hamilton Neuros syringe technology provides unprecedented functionality for controlled animal injections. The Neuros accurately dispenses volumes between 50 nL to 100 μL through an ultrafine needle with a blunt point (point style 3). Developed specifically for neuroscience applications, the Neuros enables the delivery of microvolumes to an exact location while minimizing injection site damage. Neuros syringes come with two types of protective needle sleeves. The sleeve with a blind stop is perfect for cannulated applications and ensures targeted administration with an adjustable penetration depth. The version without a blind stop works best with stereotaxic holders. Both types provide an adjustable needle exposure of 0 to 20 mm.

The Neuros adapter provides support for the ultrafine gauge needle. Its scale graduations help you set the needle exposure length.

The plunger for the 7000 series Neuros syringe is a tungsten wire that extends the entire length of the needle all the way to the tip, resulting in zero dead volume. The 700 and 1700 series Neuros syringes feature traditional plungers with 33 gauge needles resulting in minimal dead volume.

Each Neuros syringe comes with two needle sleeves—one with a blind stop (shown) for cannulated applications and another without that works best with stereotaxic holders. Both sleeves increase needle rigidity and minimize injection site damage.

The black needle sleeve is easy to see through the barrel and indicates the exposed needle length.

Adjust the needle exposure from 0–20 mm by sliding the needle sleeve in and out by hand. Tighten the nut to secure.

Volume

Model

Gauge

0.5 µL

7000.5

32

1 µL

7001

32

2 µL

7002

30

5 µL

75

33

10 µL

1701

33

25 µL

1702

33

50 µL

1705

33

100 µL

1710

33

Neuros Syringe (point style 3)

65457-01 65458-01 65459-01 65460-02 65460-05 65460-10 65460-15 65460-20

Note: The exposed needle length is adjustable from 0 to 20 mm

For more information on Neuros syringes, visit www.hamiltoncompany.com/neuros

LIFE SCIENCE SYRINGES

Page 33: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Glass Capillary Needles

Glass capillary needles offer several distinct advantages over traditional stainless steel needles. Glass needles can be pulled to form a much finer point, generally smaller than 50 μm. Even with such a small outer diameter, the glass remains rigid and resists dulling. Unlike a beveled needle, the liquid exits out the point of the needle. For several applications these features result in less damage to the animal and an overall better result for the researcher.

To simplify the use of glass capillary needles, Hamilton provides a compression fitting for 1 mm O.D. capillary tubing. When tightened into a small hub Removable Needle syringe, the compression fitting grabs onto the outside of the glass tubing to secure it to the syringe. Next, a priming kit is used to fill the syringe and needle with buffer or mineral oil, and the system is ready for use.

Pulled glass needle p/n 55750-01 RN termination

RN Compression Fitting 1 mm (p/n 55750-01)Adapts a small hub Removable Needle (RN) termination to a 1 mm pulled glass needle.

Compatible Syringes For 1 mm Glass Needle Compression Fittings

Volume

Model

5 μL

75

10 μL

1701

25 μL

1702

50 μL

1705

100 μL

1710

Removable Needle (RN) Syringe (no needle included)

7634-01 7653-01 7654-01 7655-01 7656-01

Compression Fittings (1 mm Glass Needles)

55750-01

Syringe Priming Kit PRMKIT

Note: Hamilton does not sell glass needles

Glass Needle Compression Fittings

31

LIFE SCIENCE SYRINGES

Page 34: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

RN Compression Fitting 1/16 inch (p/n 55751-01)Adapts a small hub Removable Needle (RN) termination to 1/16 inch PEEK tubing.

Dual Small Hub RN Coupler (p/n 55752-01)Connects any small hub RN connection to another small hub RN connection.

1 mm O.D. glass needle

1/16 inch PEEK tubing

Small hub Removable Needle (RN)

p/n 55752-01 1/16 inch PEEK tubing

1/16 inch PEEK tubing p/n 55751-01 RN termination

Remote Dispensing From a Syringe

There are applications where extending the fluid line between the syringe and needle is required. An example of this is using an infusion pump in combination with a stereotaxic frame. To facilitate this, Hamilton provides compression fittings that are compatible with 1/16 inch PEEK tubing. PEEK tubing is often used for HPLC and was chosen for this purpose because of its high pressure rating. When dispensing extremely small volumes, it is critical to choose tubing that will not flex during the dispense. Flexible tubing has a serious impact on the precision and reproducibility of a dispense.

The compression fitting enables the connection of PEEK tubing to any small hub Removable Needle syringe. Then a small RN coupler connects to the other end of the tubing and to the desired needle. After, the RN coupler can be mounted into the traditional syringe holder for the stereotaxic frame.

LIFE SCIENCE SYRINGES

Page 35: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Compatible Syringes For Remote Injection Compression Fittings

Volume

Model

5 μL

75

10 μL

1701

25 μL

1702

50 μL

1705

100 μL

1710

Removable Needle (RN) Syringe (no needle included)

7634-01 7653-01 7654-01 7655-01 7656-01

Compression Fittings For Remote Injections

Compression Fittings (1 mm Glass Needles) 55750-01

Compression Fittings (1/16 inch PEEK Tubing) 55751-01

Dual RN Coupler 55752-01

Syringe Priming Kit PRMKIT

Note: Hamilton does not sell PEEK tubing or glass needles

Stereotaxic Infusion Pumps

To improve control over injection rate a variety of stereotaxic mounted infusion pumps are available for Hamilton syringes. These pumps typically fit all standard Hamilton syringes from 0.5 µL to 500 µL and can achieve flow rates as low as 3.66 pL/min. These pumps attach to the flange and barrel allowing for the use of almost any needle length and termination including the new Hamilton Neuros Syringes. Check with the manufacturer of your infusion pump for syringe compatibility.

33

LIFE SCIENCE SYRINGES

Page 36: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Genomics and Biochemistry

Gel Loading Syringes

Adjustable Multi-Channel Gel Loading Syringes

Single and Multi-Channel Gel Loading Syringes

Hamilton Single and Multi-channel Gel Loading Syringes easily and accurately transfer up to eight DNA samples to sequencing gels for electrophoresis, to another microwell plate for duplicate analysis, or to nylon membranes for visualization. A single DNA syringe is also available for individual transfers. Three different needle specifications allow either loading of samples into thin sequencing gel wells that are 0.2, 0.3 or 0.4 mm or larger, or directly onto the top of the sequencing gel. The standard needle spacing of 9 mm allows spotting between the gel plates using most square or sharkstooth combs with a microwell format. An adjustable stop collar allows you to pre-set the volume anywhere between 0.2 μL to 10 μL.

Volume

Gel Thickness

Well Spacing

10 µL

0.2 mm

9–10.8 mm

Removable Needle (RN) Eight Channel Syringe (point style 3)

84611

Replacement Needle 4 pk (point style 3)

78633

Volume

Gel Thickness

Well Spacing

10 µL

9 mm

0.2 mm

10 µL

9 mm

0.3 mm

10 µL

9 mm

0.4 mm

Cemented Needle (N) Single Channel Syringe (point style 3)

80081 84505 84504

Cemented Needle (N) Eight Channel Syringe (point style 3)

84511 84503 84502

Cemented Needle (N) Replacement Syringe

80023 80022 80021

Gel Loading Syringe

LIFE SCIENCE SYRINGES

Page 37: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Terasaki Dispenser

The multi-syringe dispenser accurately dispenses six samples simultaneously up to 50 times with the press of a lever. It has been designed for rapid filling of 60 well HLA/Terasaki plates with 6.35 mm well spacing.

Terasaki Dispenser

Micro-Pipetting

The PB600-1 Repeating Dispenser consistently dispenses sample between 200 nL–50 µL, up to 50 times with the push of a button. Typical applications include protein crystallization, serology or cell culture.

Micro-Dispensing

Volume

Model

Volume to Dispense

25 µL

1702

0.5 µL

50 µL

1705

1 µL

100 µL

1710

2 µL

250 µL

1725

5 µL

500 µL

1750

10 µL

Removable Needle (RN) Syringe with Dispenser

201900 201910 201920 201930 201940

Volume

Model

Gauge

Volume Dispensed Per Click

10 µL

1701

26s

0.2 µL

25 µL

1702

22s

0.5 µL

50 µL

1705

22s

1 µL

100 µL

1710

22s

2 µL

250 µL

1725

22s

5 µL

500 µL

1750

22

10 µL

1000 µL

1001

22

20 µL

2000 µL

1002

22

50 µL

Cemented Needle (N) Syringe (point style 3)

80075 80275 80975 81075 811751 812161 813161 814161

PB600-1 Repeating Dispenser (no syringe included): 837002

Note: Needles are 51 mm1) LTN termination2) For all N syringes listed in this table

PB600-1 Repeating Dispenser Terasaki Dispenser

35

LIFE SCIENCE SYRINGES

Page 38: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Product Listing by FeaturesThis section provides feature-based descriptions of Hamilton syringes and needles along with a selection of top items within each category. Product families, series and their components are defined to help you determine the correct item that suits your specific application.

Microliter SyringesMicroliter syringes are for use with liquids only. They incorporate a hand-fitted stainless steel plunger with a finely bored syringe barrel. These syringes are ideal for aqueous and organics samples that are not prone to precipitation, crystallization or bonding with glass.

Volume

Model

Gauge

5 µL

75

26s

10 µL

701

26s

25 µL

702

22s

50 µL

705

22s

100 µL

710

22s

250 µL

725

22s

500 µL

750

22

Cemented Needle (N) Syringe (point style 2)

8790080300 80366 (6 pk)

80400 80500 80600 80700 80800

Cemented Needle (N) Syringe (point style 3)

8791980383 803652 80465 80565 80665 807651 80865

Cemented Needle (N) Syringe (specify needle)

87908 80308 80408 80508 80608 80708 80808

Removable Needle (RN) Syringe (point style 2)

8793080330 80336 (6 pk)

80430 80530 80630 80730 80830

Removable Needle (RN) Syringe (needle sold separately)

7634-01 7635-01 7636-01 7637-01 7638-01 7639-01 7640-01

Luer Tip (LT) Syringe (needle sold separately)

80301 80401 80501 80601 80701 80801

Note: Needles are 51 mm unless user specified 1) 22 gauge2) 22s gauge

A guide to syringe terminations and needle points can be found on page 4.

700 Series

The stainless steel plunger is manufactured to fit the glass barrel with a tolerance held within millionths of an inch, resulting in unsurpassed syringe life.

PRODUCT LISTING BY FEATURES

Page 39: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

800 Series

The 800 series syringes are a reinforced plunger version of the 700 series. A removable blue syringe holder is attached to the flange of the syringe that prevents heat transfer, dispense inaccuracies, plunger blow outs and plunger bending during injection.

Volume

Model

Gauge

5 µL

85

26s

10 µL

801

26s

25 µL

802

22s

50 µL

805

22s

100 µL

810

22s

250 µL

825

22s

Removable Needle (RN) Syringe (point style 2)

84851 84853 84855 84857 84859 84861

Removable Needle (RN) Syringe (needle sold separately)

7641-01 7642-01 7643-01 7644-01 7645-01 7646-01

Note: Needles are 51 mm

Volume

Model

Gauge

0.5 µL

7000.5

32

0.5 µL

7000.5

25

1 µL

7001

25

1 µL

7101

22

2 µL

7002

25

2 µL

7102

23

5 µL

7105

24

Knurled Hub (KH) Syringe (point style 2)

86259 80135 86211 88411 88511 88011

Knurled Hub (KH) Syringe (point style 3)

862571 86250 80100 86200 88400 88500 88000

Note: Needles are 70 mm1) Needle length is 100 mm

For a full list of all syringes available, visit www.hamiltoncompany.com/syringes

7000 Series

The 7000 series syringe is used for dispensing minute liquid volumes and features a Modified Microliter design. The end of the plunger has a tungsten wire extension that fits the entire length of the needle all the way to the tip, resulting in a zero dead volume syringe.

37

PRODUCT LISTING BY FEATURES

Page 40: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gastight SyringesGastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined polymer plunger tip, often PTFE, which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe barrel free of sample. This feature is useful for samples with dissolved or suspended molecules because it reduces the chance a deposit will occur and result in a damaged plunger.

Volume

Model

Gauge

1 mL

1001

22

2.5 mL

1002

22

5 mL

1005

22

10 mL

1010

22

25 mL

1025

22

50 mL

1050

22

100 mL

1100

22

Cemented Needle (LTN) Syringe (point style 2)

81317 81417 81517 81617

Cemented Needle (LTN) Syringe (point style 3)

81316 81416 81516 81616

Cemented Needle (LTN) Syringe (specify needle)

81314 81414 81514 81614

Removable Needle (RN) Syringe (point style 2)

81330 813651 81430 81530 81630

Removable Needle (RN) Syringe (needle sold separately)

7649-01 7650-01 7651-01 7652-01

Luer Tip (LT) Syringe (needle sold separately)

81301 81401 81501 81601

SampleLock (SL) Syringe (point style 2)

81356 81456 81556 81656 86326 86336 86346

PTFE Luer Lock (TLL) Syringe (needle sold separately)

81320 81420 81520 81620 82520 85020 86020

Cheminert® (C) Syringe (no needle available)

81360 81460 81560 81660

Note: Needles are 51 mm unless user specified1) Needle is point style 3

A guide to syringe terminations and needle points can be found on page 4.

1000 Series

The 1000 series syringe is a mid-volume Gastight syringe.

PRODUCT LISTING BY FEATURES

Page 41: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

1800 Series

The 1800 series syringe is the Gastight version of the 800 series syringes.

1700 Series

The 1700 series syringe is the Gastight version of the 700 series syringes.

Volume

Model

Gauge

10 µL

1701

26s

25 µL

1702

22s

50 µL

1705

22s

100 µL

1710

22s

250 µL

1725

22s

500 µL

1750

22

Cemented Needle (N) Syringe (point style 2)

80000 80200 80900 81000 811001 812171

Cemented Needle (N) Syringe (point style 3)

80075 80275 80975 81075 811751 812161

Cemented Needle (N) Syringe (specify needle)

80008 80208 80908 81008 811081 812141

Removable Needle (RN) Syringe (point style 2)

80030 80230 80930 81030 81130 81230

Removable Needle (RN) Syringe (point style 3)

800652 80265 80965 81065 811653 81265

Removable Needle (RN) Syringe (needle sold separately)

7653-01 7654-01 7655-01 7656-01 7657-01 7658-01

Luer Tip (LT) Syringe (needle sold separately)

80001 80201 80901 81001 81101 81201

SampleLock (SL) Syringe (point style 2)

80956 81056 81156 81256

PTFE Luer Lock (TLL) Syringe (needle sold separately)

80920 81020 81120 81220

Cheminert® (C) (no needle available) 80062 80262 80962 81062 81162 81262

Note: Needles are 51 mm unless user specified1) LTN termination2) 22s gauge3) 22 gauge

Volume

Model

Gauge

10 µL

1801

26s

25 µL

1802

22s

50 µL

1805

22s

100 µL

1810

22s

250 µL

1825

22s

Removable Needle (RN) Syringe (point style 2)

84877 84880 84883 84886 84889

Removable Needle (RN) Syringe (needle sold separately)

7659-01 7660-01 7661-01 7662-01 7663-01

Note: Needles are 51 mm unless user specified

39

PRODUCT LISTING BY FEATURES

Page 42: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

NeedlesHamilton Company offers the widest variety of standard and custom needles in the industry. With needle gauges from 10 to 34 and lengths from 0.375 inch (9.53 mm) to more than 12 inches (304.79 mm), almost any needle is possible. Standard needle length is 2 inches (51 mm). All needles are manufactured from 304 stainless steel.

Needle Types

Needle Type Available Gauges Remarks

Small Hub Removable Needle (RN)

27–34 Small hub removable (RN) needles can be used with removable (RN)-style syringes that are 100 μL and smaller. 18–26s

Large Hub Removable Needle (RN)

20–26s

Large hub removable (RN) needles can be used with removable (RN)-style syringes that are 250 μL and larger.

Kel-F Hub Needle (KF) 10–31Kel-F hub (KF) needles can be used with Luer Tip (LT) and PTFE Luer Lock (TLL) syringes and connectors.

Metal Hub Needle (N) 10–33Metal hub (N) (Nickel plated brass) needles can be used with TLL syringes and LT or TLL connectors.

For the first time ever, you can control the needle building process from start to finish, ensuring you get exactly what you need.

The HamiltonNeedleBuilder™

is Here!

Visit www.hamiltoncompany.com/nb to build your custom needle!

PRODUCT LISTING BY FEATURES

Page 43: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gauge O.D. X I.D. (mm) Point Style Small RN Large RN Metal Hub Kel-F Hub

33 0.21 x 0.11 3 7762-061

32 0.24 x 0.11 3 7762-05

31 0.26 x 0.13 3 7762-04

30 0.31 x 0.16 3 7762-03

28 0.36 x 0.18 3 7762-02

27 0.41 x 0.21 3 7762-01

26s 0.47 x 0.13

2 7758-02 7779-02 90039 90139

3 7768-01 7780-01 91039 90539

5 7784-07 7784-03 7729-01 7746-12

26 0.46 x 0.26

2 7758-04 7779-04 90026 90126

3 7768-02 7780-02 91026 90533

5 7784-08 7784-04 7729-03 7746-10

25 0.52 x 0.26

2 90025 90125

3 91025 90525

5 7729-04 7746-09

24 0.57 x 0.31

2 90024 90124

3 91024 90524

5 7729-05 7746-08

23 0.64 x 0.34

2 90023 90123

3 91023 90523

5 7729-06 7746-07

22s 0.72 x 0.17

2 7758-03 7779-03 90038 90138

3 7770-01 7780-03 91038 90534

5 7748-05 7784-01 7729-02 7746-11

22 0.72 x 0.41

2 7758-01 7779-01 90022 90122

3 7770-02 7780-04 91022 90134

5 7784-06 7784-02 7729-07 7746-06

21 0.82 x 0.51

2 90021 90121

3 91021 90521

5 7729-08 7746-05

20 0.91 x 0.60

2 90020 90120

3 91020 90520

5 7729-09 7746-04

Note: All needles come in a six pack and are 51 mm in length1) Length is 38.1 mm

Standard Needles

41

PRODUCT LISTING BY FEATURES

Page 44: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gauge O.D. X I.D. (mm) Point Style Small RN Large RN Metal Hub Kel-F Hub

34 0.16 x 0.05 2, 3 or 4 207434

33 0.21 x 0.11 2, 3 or 4 7803-05 7747-01

32 0.24 x 0.11 2, 3 or 4 7803-04 7747-02

31 0.26 x 0.13 2, 3 or 4 7803-03 7748-17 7750-22

30 0.31 x 0.16 2, 3 or 4 7803-07 7748-16 7750-21

29 0.34 x 0.18 2, 3 or 4 7803-06 7748-15 7750-20

28 0.36 x 0.18 2, 3 or 4 7803-02 7748-14 7750-19

27 0.41 x 0.21 2, 3 or 4 7803-01 7748-13 7750-18

26s 0.47 x 0.132, 3 or 4 7804-04 7806-04 7748-19 7750-24

5 or AS 7731-02 7732-04 7751-19 7752-19

26 0.46 x 0.262, 3 or 4 7804-03 7806-03 7748-12 7750-17

5 or AS 7731-01 7732-03 7751-17 7752-17

25s 0.52 x 0.152, 3 or 4 7804-10 7806-09 7748-21 7750-26

5 or AS 7731-06 7732-09 7751-21 7752-21

25 0.52 x 0.262, 3 or 4 7804-05 7806-07 7748-11 7750-16

5 or AS 7731-05 7732-05 7751-16 7752-16

24 0.57 x 0.312, 3 or 4 7804-08 7806-06 7748-10 7750-15

5 or AS 7731-09 7732-07 7751-15 7752-15

23s 0.64 x 0.122, 3 or 4 7804-09 7806-08 7748-20 7750-25

5 or AS 7731-08 7732-08 7751-20 7752-20

23 0.64 x 0.342, 3 or 4 7804-07 7806-05 7748-09 7750-14

5 or AS 7731-07 7732-06 7751-14 7752-14

22s 0.72 x 0.172, 3 or 4 7804-02 7806-02 7748-18 7750-23

5 or AS 7731-04 7732-02 7751-18 7752-18

22 0.72 x 0.412, 3 or 4 7804-01 7806-01 7748-08 7750-13

5 or AS 7731-03 7732-01 7751-13 7752-13

21 0.82 x 0.512, 3 or 4 7804-12 7806-11 7748-07 7750-12

5 or AS 7731-11 7732-11 7751-12 7752-12

20 0.91 x 0.602, 3 or 4 7804-11 7806-10 7748-06 7750-11

5 or AS 7731-10 7732-10 7751-11 7752-11

Note: All needles come in a six pack. Please specify needle length and point style.

Custom Needles

Point style 2 Point style 3 Point style 4 Point style 5 Point style AS

PRODUCT LISTING BY FEATURES

Page 45: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Gauge O.D. X I.D. (mm) Point Style Small RN Metal Hub Kel-F Hub

19 1.07 x 0.692, 3 or 4 207419 7748-05 7750-10

5 or AS 7751-10 7752-10

18 1.27 x 0.842, 3 or 4 7804-06 7748-04 7750-09

5 or AS 7751-09 7752-09

17 1.47 x 1.072, 3 or 4 7748-03 7750-08

5 or AS 7751-08 7752-08

16 1.65 x 1.192, 3 or 4 7748-02 7750-07

5 or AS 7751-07 7752-07

15 1.83 x 1.372, 3 or 4 7748-01 7750-06

5 or AS 7751-06 7752-06

14 2.11 x 1.602, 3 or 4 7749-05 7750-05

5 or AS 7751-05 7752-05

13 2.41 x 1.802, 3 or 4 7749-04 7750-04

5 or AS 7751-04 7752-04

12 2.77 x 2.162, 3 or 4 7749-03 7750-03

5 or AS 7751-03 7752-03

11 3.05 x 2.392, 3 or 4 7749-02 7750-02

5 or AS 7751-02 7752-02

10 3.40 x 2.702, 3 or 4 7749-01 7750-01

5 or AS 7751-01 7752-01

Note: All needles come in a six pack. Please specify needle length and point style.

Custom Needles continued

Custom needles usually ship within 5–7 business days.

43

PRODUCT LISTING BY FEATURES

Page 46: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

The life of your Hamilton syringe is directly related to its cleanliness and proper care. In general, solvents suitable for routine cleaning include methanol, acetonitrile and acetone. Use solvents of high purity grade. Halogenated hydrocarbons should not be used because they may damage some glue joints.

Syringe Care and Use

Chemical Compatibility

The adhesive used to affix needles and hubs to Hamilton Gastight and Microliter syringes is the most chemically resistant available. However, with prolonged exposure, some solvents may attack and deteriorate this highly resistant adhesive. In particular, caution should be exercised with solvents containing halogenated hydrocarbons such as dichlormethane (methylene chloride). For applications using these solvents, Removable Needle (RN) syringes are recommended because no adhesive is present in the fluid path. Be sure to rinse the syringe thoroughly after each use with a solvent that is known to solubilize your sample followed by a solvent such as acetone to ensure that the glue does not remain in contact with a potentially harmful solvent.

Cleaning Syringes

Rinse the syringe after use with an appropriate solvent (i.e., a solvent known to be effective in solvating the sample). Preferred cleaning agents are non-alkaline, non-phosphate and non-detergent based. A biodegradable, non-phosphate, organic Cleaning Solution Concentrate is available from Hamilton (p/n 18311). Following the use of a cleaning agent, rinse the syringe with deionized water and finally acetone. Wipe the exterior surfaces of the syringe barrel and needle dry with a lint-free tissue. Make sure that there is no residual cleaning agent in the syringe before using or storing the syringe. Do not soak or submerse the entire syringe in any cleaning agent. Prolonged contact with cleaning agents may damage bonded parts. It is recommended that the syringe be placed into the original packaging after it is properly cleaned.

Needle Cleaning Kit

SYRINGE CARE AND USE

Page 47: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Clogged Needles

Do not attempt to clean clogged needles by forcing liquid or compressed air through the syringe. Excessive pressure will split the glass barrel. Instead, use the Hamilton Needle Cleaning Kit (p/n 76620). Start by using the cleaning wires to dislodge any foreign material. Then flush with the Cleaning Solution Concentrate to further dissolve the clog. Once the clog is removed, rinse the syringe and needle thoroughly with deionized water. Wipe the exterior surfaces of the syringe barrel and needle dry with a lint-free tissue. Make sure that there is no residual cleaning agent in the syringe before using or storing the syringe.

Storage

After Hamilton syringes are cleaned and dried store them in the original packaging or on the syringe rack (p/n 204880) to prevent breakage or damage.

Sterilizing Syringes

Chemical sterilizers are the best means for sterilizing syringes. Hamilton syringes may be sterilized with ethylene oxide. LT, TLL and disassembled RN syringes may be autoclaved at a temperature of up to 115 °C. However, repeated autoclaving will shorten syringe life. When autoclaving is required, remove the plunger from the syringe. Autoclaving cemented needle syringes is not recommended as glass and metal expands at different rates which would compromise the glued connection. If your application only requires disinfection, then Hamilton recommend the use of Microside SQ®.

Lubricating Syringes

A clean syringe does not require any lubricating grease. Grease may lead to a variety of problems including sample contamination, seizing of the plunger and barrel damage. Syringe Rack

45

SYRINGE CARE AND USE

Page 48: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Problem Possible Cause Suggested Solution

Clogged needle

Worn GC septa Replace GC septa

Poor syringe cleaningEnsure proper needle cleaning with Hamilton cleaning wires and cleaning concentrate

Viscous sample Select a larger needle gauge for viscous sample

Bent plunger

Inappropriate handling technique Use syringe with reinforced plunger

Poor storageStore syringes on the syringe rack or in their original packaging

Seized Microliter plunger

Deposits between the glass barrel and the plunger wire

Avoid operating the syringe dry

Ensure proper syringe cleaning, it may be possible to free the plunger using a solvent known to solublize your sample

Low reproducibility Inappropriate handling technique Use Reproducibility (Chaney) Adapter

Air bubbles Insufficient primingFully prime the syringe by inserting the needle into the sample and slowly aspirating and dispensing

Needle leakage Inappropriate sealing of the needleRemount needle checking that the cleaning wire has been removed and there is no damage to the plastic seal

Cemented needle is loose

Solvents have attacked the glue holding the needle

Use RN syringes that have no glue in the fluid path, especially with halogenated solvents

Gastight plunger leakage

Plunger tip damaged due to age Replace plunger

Plunger tip damage due to deposits on the glass

Improve cleaning to eliminate deposits. For some applications SaltLine syringes may provide longer life.

CarryoverInappropriate syringe cleaning Ensure proper syringe and needle cleaning

Inappropriate syringe selection Use a Gastight syringe with aqueous samples

Syringe Troubleshooting

SYRINGE CARE AND USE

Page 49: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Part Number IndexPRMKIT............................ 31, 337634-01 ............... 29, 31, 33, 367635-01 .................................367636-01 .................................367637-01 ..................................367638-01 .................................367639-01 .................................367640-01 .................................367641-01 ..................................377642-01 .................................377643-01 .................................377644-01 .................................377645-01 .................................377646-01 .................................377649-01 .................................387650-01 .................................387651-01 ..................................387652-01 .................................387653-01 ............... 29, 31, 33, 397654-01 ............... 29, 31, 33, 397655-01 ............... 29, 31, 33, 397656-01 ............... 29, 31, 33, 397657-01 ..................................397658-01 .................................397659-01 .................................397660-01 .................................397661-01..................................397662-01 .................................397663-01 .................................397729-01 ................................. 417729-02 ................................. 417729-03 ................................. 417729-04 ................................. 417729-05 ................................. 417729-06 ................................. 417729-07 ................................. 417729-08 ................................. 417729-09 ................................. 417731-01 ..................................427731-02 .................................427731-03 .................................427731-04 .................................427731-05 .................................427731-06 .................................427731-07 ..................................427731-08 .................................427731-09 .................................427731-10 ..................................427731-11 ..................................427732-01 .................................427732-02 .................................427732-03 .................................427732-04 .................................427732-05 .................................427732-06 .................................427732-07 .................................427732-08 .................................427732-09 .................................427732-10 ..................................427732-11 ..................................427746-04 ................................. 417746-05 ................................. 417746-06 ................................. 417746-07 ................................. 417746-08 ................................. 417746-09 ................................. 417746-10 .................................. 417746-11 .................................. 41

7746-12 .................................. 417747-01 ..................................427747-02 ..................................427748-01 .................................437748-02 .................................437748-03 .................................437748-04 .................................437748-05 ........................... 41, 437748-06 .................................427748-07 .................................427748-08 .................................427748-09 .................................427748-10 ..................................427748-11 ..................................427748-12 ..................................427748-13 ..................................427748-14 ..................................427748-15 ..................................427748-16 ..................................427748-17 ..................................427748-18 ..................................427748-19 ..................................427748-20..................................427748-21 ..................................427749-01 .................................437749-02 .................................437749-03 .................................437749-04 .................................437749-05 .................................437750-01 .................................437750-02 .................................437750-03 .................................437750-04 .................................437750-05 .................................437750-06 .................................437750-07 .................................437750-08 .................................437750-09 .................................437750-10 ..................................437750-11 ..................................427750-12 ..................................427750-13 ..................................427750-14 ..................................427750-15 ..................................427750-16 ..................................427750-17 ..................................427750-18 ..................................427750-19 ..................................427750-20 .................................427750-21 .................................427750-22 .................................427750-23 .................................427750-24 .................................427750-25 .................................427750-26 .................................427751-01 ..................................437751-02 ..................................437751-03 ..................................437751-04 ..................................437751-05 ..................................437751-06 ..................................437751-07 ..................................437751-08 ..................................437751-09 ..................................437751-10 ..................................437751-11 ..................................427751-12 ..................................427751-13 ..................................42

7751-14 ..................................427751-15 ..................................427751-16 ..................................427751-17 ..................................427751-18 ..................................427751-19 ..................................427751-20 ..................................427751-21 ..................................427752-01 .................................437752-02 .................................437752-03 .................................437752-04 .................................437752-05 .................................437752-06 .................................437752-07 .................................437752-08 .................................437752-09 .................................437752-10 ..................................437752-11 ..................................427752-12 ..................................427752-13 ..................................427752-14 ..................................427752-15 ..................................427752-16 ..................................427752-17 ..................................427752-18 ..................................427752-19 ..................................427752-20 ..................................427752-21 ..................................427758-01 ................................. 417758-02 ......................... 7, 8, 417758-03 ......................... 7, 8, 417758-04 ................................. 417762-01 ................................. 417762-02 ................................. 417762-03 ................................. 417762-04 ................................. 417762-05 ................................. 417762-06 ................................. 417768-01 ................................. 417768-02 ................................. 417770-01 ............................17, 417770-02 ................................. 417779-01 ......................... 7, 8, 417779-02 ................................. 417779-03 ......................... 7, 8, 417779-04 ................................. 417780-01 ................................. 417780-02 ................................. 417780-03 ............................17, 417780-04 ............................17, 417784-01 ................................. 417784-02 ................................. 417784-03 ................................. 417784-04 ................................. 417784-06 ................................. 417784-07 ................................. 417784-08 ................................. 417787-01 ..................................187787-02 ..................................187803-01 ...........................29, 427803-02 ...........................29, 427803-03 ...........................29, 427803-04 ...........................29, 427803-05 ...........................29, 427803-06 ...........................29, 427803-07 ...........................29, 427804-01 .................................42

7804-02 .................................427804-03 .................................427804-04 .................................427804-05 .................................427804-06 .................................437804-07 .................................427804-08 .................................427804-09 .................................427804-10 ..................................427804-11 ..................................427804-12 ..................................427806-01 .................................427806-02 ........................... 18, 427806-03 .................................427806-04 .................................427806-05 .................................427806-06 .................................427806-07 .................................427806-08 .................................427806-09 .................................427806-10 .................................427806-11 ..................................4214700 ................................. 9, 1814725 ................................. 9, 1818311 .....................................4420912 .....................................2720918 .....................................2720922 ....................................2720930 ....................................2754658-01 ................... 23, 24, 2554659-01 ................... 23, 24, 2554660-01 ................... 23, 24, 2554661-01 ................... 23, 24, 2554662-01 ................... 23, 24, 2555750-01 ......................... 31, 3355751-01 ................................3355752-01 ...............................3359000-05 ...............................2759000-10 ...............................2759000-15 ...............................2759000-20 ...............................2759000-25 ...............................2759000-30 ...............................2759000-35 ...............................2759000-40 ...............................2759000-45 ...............................2759000-50 ...............................2759000-55 ...............................2759000-60 ...............................2762161-01 .................... 23, 24, 2565457-01 ...............................3065458-01 ...............................3065459-01 ...............................3065460-02 ...............................3065460-05 ...............................3065460-10 ...............................3065460-15 ...............................3065460-20 ...............................3076620 .....................................4578633 ....................................3480000 ................................8, 3980001 ....................................3980008 ....................................3980021 ....................................3480022 ....................................3480023 ....................................3480030 ................................8, 3980050 ....................................1980062 ....................................3980065 .............................. 17, 3980075 ...............................35, 39

47

INDEX

Page 50: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

80079..................................... 1380080 .................................... 1380081 ....................................3480094 ....................................1380096 .................................... 1380100 .....................................3780135 ................................. 7, 3780176 .....................................1380200 ................................8, 3980201.....................................3980208 ....................................3980230 ................................8, 3980231 .....................................1880250 ....................................1980262 ....................................3980265 .............................. 17, 3980275 ......................... 17, 35, 3980300 .......................... 7, 14, 3680301 ....................................3680308 ..............................10, 3680318 ..................................... 1480330 .......................... 7, 15, 3680336 ................................ 7, 3680365 .............................. 17, 3680366 .......................... 7, 14, 3680383 ....................................3680387 ....................................1380388 ....................................1380389 ....................................1380390 ....................................1380391 .................................... 1380393 ....................................1380400 ................................ 7, 3680401 ....................................3680408 ....................................3680430 ................................ 7, 3680465 .............................. 17, 3680500 ................................ 7, 3680501 ....................................3680508 ....................................3680530 ................................ 7, 3680565 .............................. 17, 3680600 ................................ 7, 3680601 ....................................3680608 ....................................3680630 ................................ 7, 3680665 .............................. 17, 3680700................................. 7, 3680701 .....................................3680708 .....................................3680730 ................................. 7, 3680765 ............................... 17, 3680800 ................................ 7, 3680801 ....................................3680808 ....................................3680830 ................................ 7, 3680865 .............................. 17, 3680900 ................................8, 3980901 ....................................3980908 ....................................3980920 .............................. 27, 3980930 ................................8, 3980931 ....................................1880950 ....................................1980956 ....................................3980962 ..............................25, 3980965 .............................. 17, 3980975 ......................... 17, 35, 3981000 .................................8, 3981001 .....................................39

81008 .....................................3981020 ............................... 27, 3981030 .................................8, 3981031 .....................................1881050 .....................................1981056 .....................................3981062 .....................................3981065 ............................... 17, 3981075 ......................... 17, 35, 3981100 .................................8, 3981101 .....................................3981108 .....................................3981120 ............................... 27, 3981130 .................................8, 3981131 .....................................1881156 .....................................3981162 ...............................25, 3981165 ............................... 17, 3981175 ......................... 17, 35, 3981201 .....................................3981214 .....................................3981216 ......................... 17, 35, 3981217 .................................8, 3981220 ............................... 27, 3981230 .................................8, 3981231 .....................................1881256 .....................................3981262 ...............................25, 3981265 ............................... 17, 3981301 .....................................3881314 .....................................3881316 ......................... 17, 35, 3881317 .................................8, 3881320 ............................... 27, 3881330 .................................8, 3881331 .....................................1881356 .....................................3881360 .........................23, 25, 3881365 ............................... 17, 3881401 .....................................3881414 .....................................3881416 ...............................35, 3881417 .................................8, 3881420 ............................... 27, 3881430 .................................8, 3881456 .....................................3881460 .........................23, 25, 3881501 .....................................3881514 .....................................3881516 .....................................3881517 .................................8, 3881520 ............................... 27, 3881530 .................................8, 3881556 .....................................3881560 ...............................23, 3881601 .....................................3881614 .....................................3881616 .....................................3881617 .................................8, 3881620 ............................... 27, 3881630 .................................8, 3881656 .....................................3881660 .....................................3882520 ............................... 27, 3884502 ....................................3484503 ....................................3484504 ....................................3484505 ....................................3484511 .....................................3484611 .....................................34

84851 .....................................3784853 ....................................3784855 ....................................3784857 ....................................3784859 ....................................3784861 ....................................3784877.................................8, 3984880 ................................8, 3984883 ................................8, 3984886 ................................8, 3984889 ................................8, 3985020 .............................. 27, 3886020 .............................. 27, 3886200 ....................................3786201 .......................................786211 .....................................3786250.....................................3786257 .....................................3786259................................. 7, 3786274 ..................................... 1386276 ..................................... 1386326 ....................................3886336 ....................................3886346 ....................................3887402 .....................................1087900 .......................... 7, 14, 3687908.....................................3687919 .....................................3687930 ........................... 7, 15, 3687987 ..................................... 1387988 .....................................1387989 ..................................... 1387990..................................... 1387993 .....................................1387994 .....................................1388000 ....................................3788011 ................................. 7, 3788400 ....................................3788411 ................................. 7, 3788500 ....................................3788511 .....................................3790020 .................................... 4190021 .................................... 4190022 .................................... 4190023 .................................... 4190024 .................................... 4190025 .................................... 4190026 .................................... 4190038 .................................... 4190039 .................................... 4190120 ..................................... 4190121 ..................................... 4190122 ..................................... 4190123 ..................................... 4190124 ..................................... 4190125 ..................................... 4190126 ..................................... 4190134 ..................................... 4190138 ..................................... 4190139 ..................................... 4190520 .................................... 4190521..................................... 4190523 .................................... 4190524 ..................................... 4190525..................................... 4190533 .................................... 4190534 .................................... 4190539 .................................... 4190612 .....................................2790618 .....................................27

90622 ....................................2790630 ....................................2790662 ....................................2790668 ....................................2790672 ....................................2790680 ....................................2791020 ..................................... 4191021 ..................................... 4191022 ..................................... 4191023 ..................................... 4191024 ..................................... 4191025 ..................................... 4191026 ..................................... 4191038 ..................................... 4191039 ..................................... 41201900 ...................................35201910 ...................................35201920 ...................................35201930 ...................................35201940 ...................................35202145 ...................................23202192 ...................................23202630 .................................. 15202640 .................................. 15202660 .................................. 14202880 .................................. 14203043 .................................. 12203075 ....................... 21, 23, 24203076 ................................... 12203077....................... 21, 23, 24203078 ................................... 12203079 ....................... 21, 23, 24203080 .................................. 12203081 ...................... 21, 23, 24203082 .................................. 12203083 ...................... 21, 23, 24203084 .................................. 12203085 ...................... 21, 23, 24203086 .................................. 12203141 ................................... 12203181 ................................... 12203182 ................................... 12203185 ................................... 12203189 ................................... 12203194 ....................... 21, 23, 24203205 .................................. 12203220...................................27203230 ..................................27203240 ...................................27203250...................................27203260 ..................................27203270 ...................................27203349 ...................... 21, 23, 24203361 .................................. 12204000 .................................. 14204001 .................................. 14204051 ................................... 14204052 .................................. 14204379 ...................................21204400 ..................................21204452 ..................................21204475 ...................................21204880 ..................................45207419 ...................................43207434 .............................29, 42208335 ..................................27208336 ..................................27208337 ..................................27

INDEX

Page 51: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Hamilton Company is a global enterprise with headquarters in Reno, Nevada, Hopkinton, Massachusetts, and Bonaduz, Switzerland and subsidiary offices throughout the world.

We are an industry leader in the design and manufacture of liquid handling, process analytics, robotics and automated storage solutions. For more than 50 years, Hamilton has been satisfying customer needs by combining quality materials with skilled workmanship to ensure the highest level of performance. Hamilton’s lifelong commitment to precision and quality has earned us global ISO 9001 Certification.

Hamilton Company is focused on blending invention and accuracy to deliver customers unparalleled products.

About Hamilton Company

Founded on the technology of analytical Microliter™ and Gastight® syringes, Hamilton has a broad offering of laboratory products including manual and semi-automated precision fluid measuring instruments, chromatography products, process sensors, laboratory electrodes, pipettes and more. Top innovations from these lines include Arc™ pH, DO and conductivity intelligent sensors, the BioLevitator™ and Microlab® 600 diluters/dispensers.

A pioneer in liquid handling equipment and laboratory automation technology, Hamilton Robotics is known for advancing life science and biotechnology industries through reliability, performance and flexibility. Hamilton continues to be the market leader with patented technologies such as Compression-induced O-Ring Expansion (CO-RE), Total Aspiration and Dispensing Monitoring (TADM) and Anti Droplet Control (ADC). Hamilton’s feature platform, Microlab STAR, is the highest selling automated pipetting platform for several years running, while Microlab NIMBUS® is the first in class of compact, high-speed personalized pipetting workstations.

The Hamilton Storage Technologies division offers comprehensive ultra-low temperature automated sample management systems for a broad array of life science processes. Its line of biobanking, compound storage and consumable solutions consists of products such as BiOS™, SAM™ and ASM™, designed for sample integrity, flexibility, and reliability.

Page 52: Syringe Catalog - Chromspec series and family definitions See more on page 4 Neuroscience animal injections See more on page 30 HPLC autosampler syringes See more on page 20

Your Hamilton Representative

Hamilton Americas & Pacific Rim4970 Energy WayReno, Nevada 89502 USATel: +1-775-858-3000Fax: [email protected]

Hamilton Europe, Asia, & AfricaVia Crusch 8CH-7402 Bonaduz, GR, SwitzerlandTel: +41-81-660-60-60Fax: [email protected]

Web: www.hamiltoncompany.comUSA: 800-648-5950Europe: +41-81-660-60-60 To find a representative in your area, please visit hamiltoncompany.com/contacts.

© 2012 Hamilton Company. All rights reserved. Thermo Scientific is a registered trademark of Thermo Fisher Scientific Inc.

Valco® and Cheminert® are registered trademarks of Valco Instruments Co. Inc.

Rheodyne is a registered trademark of Units of IDEX® Corporation.

Waters is a registered trademark of Waters.

PerkinElmer and Flexar are registered trademarks of PerkinElmer, Inc.

Merlin MicroSeal is a trademark of Merlin Instrument Company.

Microside SQ is a registered trademark of Global Biotechnologies, Inc. in the U.S. and/or other countries.

PAL is a registered trademark of CTC Analytics AG, Switzerland.

All other trademarks are owned and/or registered by Hamilton Company in the U.S. and/or other countries.

Lit. No. L20078 — 03/2012