O & M
OF220 KV
SUB-STATIONS
-
8/7/2019 switch maintanence
2/33
2
SUB-STATION
SWITCH YARDCONTROL & RELAYPANELS / CIRCUITS
AUXILLARIES
-
8/7/2019 switch maintanence
3/33
3
SWITCH YARD
TRANSFORMER
CIRCUIT BREAKER
CURRENT TRANSFORMER
CAPACITIVE VOLTAGE TRANSFORMER LIGHTNING ARRESTER
ISOLATOR
WAVE TRAP BUS BAR & JUMPERS
STRUCTURES
-
8/7/2019 switch maintanence
4/33
4
TRANSFORMER
BUSHINGS MAIN TANK, INCLUDING PROTECTIVE
DEVICES
TAP CHANGER COOLING SYSTEM
MARSHALLING BOX
WHEELS LOCKING
EARTHING
RTCC
-
8/7/2019 switch maintanence
5/33
5
BUSHINGS
OIL LEVEL OF BUSHINGS / LEAKAGE CLEANLINESS & FREE FROM CRACKS,
CHIPS & GRIME ETC
PERFECTNESS FOR CONNECTIONS
PROPER DISTANCE OF ROD GAPARRESTORS
PROPER EARTHING OF CONDENSOR
UNIT TIGHTNESS OF BUSHING, TERRETS,
TERRET CTs ETC
-
8/7/2019 switch maintanence
6/33
6
MAIN TANK, INCLUDING
PROTECTIVE DEVICES OIL LEVEL / LEAKAGE
PROPER TIGHTENING OF TANK COVER /BELL / PIPINGS / WHEELS / CONSERVATORETC
PROPER MOUNTING OF PRV / SPR /BUCHHOLZ RELAY / WTI CT CHAMBERS /OTI OIL POCKETS / MOG / AIR CELL ETC
PROPER INCLINATION OF AUXILLARYPIPING & MAIN PIPE
PROPER WORKING OF THERMOSYPHON
-
8/7/2019 switch maintanence
7/33
7
TAP CHANGER
OIL LEVEL / LEAKAGE MOUNTING OF OLTC CONSERVATOR
WORKING OF OIL SURGE RELAY
PROPER WORKING OF OLTCMECHANISM
ELECTRICAL & MANUAL OPERATIONS
OF TAP CHANGER
-
8/7/2019 switch maintanence
8/33
8
COOLING SYSTEM
LEAK FREE RADIATORS / HEADERS /PUMPS ETC
THERMAL BEHAVIOUR OF RADIATORS
PROPER FUNCTIONING OF PUMPS /COOLING FANS
BEHAVIOUR OF FLOW METER
FIRMNESS OF SUPPORTINGSTRUCTURE FOR VIBRATION FREEOPERATION OF COOLING SYSTEM
-
8/7/2019 switch maintanence
9/33
9
MARSHALLING BOX PROPER FUNCTIONING OF OTI & WTIs
PROPER WORKING OF COOLING FANSTARTERS, CONTACTORS, OVERLOADRELAYS, SINGLE PHASE PREVENTERS
PROPER FUNCTIONING OF SWITCHES,FUSE, LINKS
KINK LESS / DAMAGE FREE CAPILLIARYTUBES
VERMAIN PROOF CUBICLE
PROPER CABLING & WIRING
-
8/7/2019 switch maintanence
10/33
10
EARTHING
PROPER EARTHING OF ALLNEUTRALS
PROPER EARTHING OF TANK BODY,SUPPORTING STRUCTURES, COOLINGFANS, MARSHALLING BOX, OLTC,
RTCC ETC
-
8/7/2019 switch maintanence
11/33
11
RTCC
PROPER WORKING OF OTI &WTIREPEATERS
PROPER WORKING OF TPI
PROPER WORKING OF ALARMS &INDICATIONS
PROPER WORKING OF COOLINGSYSTEM & TAP CHANGER FROM
REMOTE PARALLEL OPERATION, IF PROVIDED
AVR, IF REQUIRED / FUNCTIONAL
-
8/7/2019 switch maintanence
12/33
12
ROUTINE TESTS
MEASUREMENT OF IR - AC / PI
MEGNATISING CURRENT
MEGNATIC BALANCE
TURN RATIO / VOLTAGE RATIO WINDING RESISTANCE
SHORT CIRCUIT TEST
TERRET CT / WTI CT RATIO DC LOGIC TEST
BDV OF OIL
EARTH RESISTANCE
-
8/7/2019 switch maintanence
13/33
13
SPECIAL TEST
OIL
DGA OF INSULATING OIL
MOISTURE CONTENT
INTERFACIAL TENSION TAN DELTA
RESISTIVITY
THERMAL BEHAVIOUR OF TANK & BUSHINGS CAPACITANCE & TAN DELTA MEASUREMENT
OF BUSHINGS AND WINDINGS
-
8/7/2019 switch maintanence
14/33
14
LIFE ASSESSMENT TESTS
FRA
RVM
FURAN / FURFURAL (FFA) ANYLYSIS
PARTIAL DISCHARGE METHOD
THERMOVISION
BUCHHOLZ GAS ANALYSIS
DOMINO
-
8/7/2019 switch maintanence
15/33
15
CIRCUIT BREAKERS
CHECK MEDIUM OF EXTINGUISHING CHAMBER
FOR LEAKAGE & REQUIRED PRESSURE / LEVEL
OIL / GAS / AIR
MEASURE CONTACT RESISTANCE TO ENSURE
HEALTHINESS OF CONTACTS
CHECK TIMINGS FOR PERFECT OPERATION
C O CO
AVOID SLUGISH / DELAYED OPERATIONS
ENSURE PERFECTNESS OF AUXILIARY
CONTACTS AND INTERLOCKS
ENSURE DUTY CYCLE OF CB
-
8/7/2019 switch maintanence
16/33
16
CHECK CLAMPS / CONNECTORS
PERFORM DC LOGIC TEST
INSULATION RESISTANCE MEASUREMENT- MAIN CB
- AUXILIARY WIRING
MEASUREMENT OF EARTH RESISTANCE
SPECIAL TESTS LIKE MEASUREMENT OF( WITH CB ANALYSER ) -
- WIPE / TRAVEL / OVERTRAVEL / BOUNCES
- VELOCITY- OPERATING TIMINGS OF AUXILIARY CONTACTS
- AMPERES TAKEN BY CLOSING / OPENING COILS
DEW POINT MEASUREMENT ( OF GAS ) *
-
8/7/2019 switch maintanence
17/33
17
FOR MOCBS & BOCBS
- OIL LEVEL / LEAKAGES- BDV OF OIL
- SILICA GEL
- AIR VENT / VALVE
- MEASUREMENT OF TRAVEL H
- RESIDUE & SLUDGE
- CONDITION OF GASKETS
-
8/7/2019 switch maintanence
18/33
18
OPERATING MECHANISM
OPERATION OF SPRING CHARGING MOTOR WORKING OF COMPRESSOR AND ITS MOTOR
FUNCTIONING / CALIBRATION OF PRESSURESWITCHES / LIMIT SWITCHES / INTERLOCKS
EMERGENCY TRIP
VERMAIN PROOFING
FIRMNESS / TIGHTNESS
LUBRICATION - OIL, GREASE WORKING OF DAMPING DEVICES
-
8/7/2019 switch maintanence
19/33
19
CURRENT TRANSFORMERS
CHECK FOR OIL LEVEL AND LEAKAGES
TIGHTNESS OF PRIMARY & SECONDARY
TERMINALS
PERFORMANCE OF BELLOW / DIAPHRAGM
/ VENT PLUG
PRESENCE OF NITROGEN
CONDITION OF INSULATORS (Main & Auxiliary) CRACKS IN GASKETS
CLAMPS AND CONNECTORS
-
8/7/2019 switch maintanence
20/33
20
BDV OF OIL
INSULATION RESISTANCE( KEEP A TRACK RECORD )
RATIO TEST
EARTHING
CAUTION : ENSURE THAT
-CT (LIVE) TANK HAS NOT BECOME ,
AFTER REPAIRS , A CONDUCTOR
- UNUSED CORES ARE SHORT CIECUITED- SECONDARY CIRCUITS ARE NOT OPEN CKTD
- BALANCE LOADING OF SECONDARY CIRCUITS
-
8/7/2019 switch maintanence
21/33
21
POTENTIAL TRANSFORMER
OIL LEVEL AND LEAKAGE
PRIMARY AND SECONDARY TERMINALS
GASKETS FOR CRACKS
CLAMPS AND CONNECTORS
VOLTAGE RATIO
BALANCED LOADING OF SECONDARY CKTS
BDV OF OIL
CHECK BURDEN ON SECONDARY CIRCUITS
EARTHING
-
8/7/2019 switch maintanence
22/33
22
CAPACITIVE VOLTAGE
TRANSFORMER OIL LEVEL AND LEAKAGE
PRIMARY AND SECONDARY TERMINALS
GASKETS FOR CRACKS
HARDWARES
VOLTAGE RATIO
BALANCED LOADING OF SECONDARY CKTS
BDV OF OIL
MEASUREMENT OF CAPACITANCE AND TAN DELTA HF TERMINAL
CHECK BURDEN ON SECONDARY CIRCUITS
-
8/7/2019 switch maintanence
23/33
-
8/7/2019 switch maintanence
24/33
24
LIGHTNING ARRESTER
EARTHING
CLAMPS AND CONNECTORS SURGE COUNTER
ENSURE FLOW OF LEAKAGE CURRENT
COMPARATIVE STUDY OF IR
-
8/7/2019 switch maintanence
25/33
25
ISOLATORS
ALIGNMENT OF FIXED AND MOVING
CONTACTS / JAWS
CONTACT RESISTANCE
MECHANICAL AND ELECTRIC INTERLOCKS
EARTH BLADES
SMOOTH OPERATION OF MOVING PARTS
CLAMPS AND CONNECTORS
EARTHING
-
8/7/2019 switch maintanence
26/33
26
ISOLATOR MOM
HEALTHINESS OF GEARS / WHEELS / SHAFT
OPERATION OF LIMIT SWITCHES
WORKING AND ALIGNMENT OF AUXILIARY
CONTACTS
MOTOR
CONTACTOR AND OVERLOAD RELAY
OILING AND GREASING EARTHING
-
8/7/2019 switch maintanence
27/33
27
BUS BAR , SCREEN WIRE ,
HARDWARES & JUMPERS
PROPER COVERAGE BY SCEEN WIRE
DAMAGE TO HARDWARE , CLAMPS ,
CONNECTORS , SPACERS TOO LONG JUMPERS BE PROPERLY
SUPPORTED
BI METALLIC EFFECT
BINDING WIRE
KINKS AND DAMAGED BUS BAR / JUMPERS
-
8/7/2019 switch maintanence
28/33
28
STRUCTURES
PROPER TIGHTNESS
MISSING MEMBERS
EARTHING
NESTS
-
8/7/2019 switch maintanence
29/33
29
CONTROL & RELAY
PANELS / CIRCUITS CONTROL PANELS
RELAY PANELS
COMBINATION OF CONTROL AND RELAYPANELS
CONTROL CABLES
CONTROL AND PROTECTION CIRCUITS TKS
SPACE HATERS
-
8/7/2019 switch maintanence
30/33
30
AUXILLARIES
LOCAL AC NET WORK
DC NETWORK
COMMUNICATION SYSTEM
DG SET CONTROL ROOM BUILDING AND
ASSOCOATED INFRASTRUCTURE
FIRE FIGHTING EQUIPMENTS
SUMP PUMP
BASIC AMENITIES
-
8/7/2019 switch maintanence
31/33
31
PAINTING
OF
EQUIPMENTSAND SUPPORTING
STRUCTURES
-
8/7/2019 switch maintanence
32/33
32
SAY GOOD BYE TO
RUST
DUST
MOISTURE
LOOSECONTACT
BI METALLIC EFFECT
-
8/7/2019 switch maintanence
33/33