1 Electrochemical piezoelectric-excited millimeter-sized cantilever (ePEMC) for simultaneous dual transduction biosensing [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj Mutharasan Department of Chemical and Biological Engineering, Drexel University, Philadelphia, PA 19104 Submitted to: Editor, Analyst *Corresponding author, Tel.: (215) 895-2236. Fax: (215) 895-5837 Email: [email protected] Electronic Supplementary Material (ESI) for Analyst This journal is © The Royal Society of Chemistry 2013

Upload: others

Post on 19-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj ... · Blake N. Johnson and Raj Mutharasan ∗ Department of Chemical and Biological Engineering, Drexel University, Philadelphia,

1

Electrochemical piezoelectric-excited millimeter-sized cantilever (ePEMC) for

simultaneous dual transduction biosensing

[SUPPLEMENTARY MATERIALS]

Blake N. Johnson and Raj Mutharasan∗

Department of Chemical and Biological Engineering,

Drexel University, Philadelphia, PA 19104

Submitted to:

Editor, Analyst

*Corresponding author, Tel.: (215) 895-2236. Fax: (215) 895-5837

Email: [email protected]

Electronic Supplementary Material (ESI) for AnalystThis journal is © The Royal Society of Chemistry 2013

Page 2: [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj ... · Blake N. Johnson and Raj Mutharasan ∗ Department of Chemical and Biological Engineering, Drexel University, Philadelphia,

2

These supplementary materials show photographs comparing the ePEMC sensor and flow

cell with an EQCM. We also provide comparison of equivalent circuit models useful for

examining ePEMC EIS response. Figures S.1 and S.2 compare the sensors, and Figure S.3

compares the flow cells. Figure S.4 shows the EIS spectrum of a representative ePEMC prior to

biosensing with the fits of three equivalent circuit models that facilitate calculation of the charge

transfer resistance parameter (RCT) used to transduce molecular binding in the electrochemical

sensing modality of ePEMC.

Electronic Supplementary Material (ESI) for AnalystThis journal is © The Royal Society of Chemistry 2013

Page 3: [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj ... · Blake N. Johnson and Raj Mutharasan ∗ Department of Chemical and Biological Engineering, Drexel University, Philadelphia,

3

Figure S.1– Comparison of ePEMC with a commercially available electrochemical-quartz crystal

microbalance (EQCM) (Stanford Research Systems, SRS, Sunnyvale, CA).

ePEMCEQCM

Piezo-driving electrodes

Surface electrodes

Sensing electrode

Electronic Supplementary Material (ESI) for AnalystThis journal is © The Royal Society of Chemistry 2013

Page 4: [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj ... · Blake N. Johnson and Raj Mutharasan ∗ Department of Chemical and Biological Engineering, Drexel University, Philadelphia,

4

Figure S-2 – Close-up view of sensor working electrodes. EQCM sensor has working electrode

area ~ cm2; ePEMC sensor has working electrode ~ mm2.

Sensing electrode

Electronic Supplementary Material (ESI) for AnalystThis journal is © The Royal Society of Chemistry 2013

Page 5: [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj ... · Blake N. Johnson and Raj Mutharasan ∗ Department of Chemical and Biological Engineering, Drexel University, Philadelphia,

5

Figure S.3 – (A) Flow cells used for EQCM sensing and ePEMC sensing. Reactor hold-up

volumes were 150 μL and ~300 μL, respectively. Finite element modeling software (COMSOL

Multiphysics, Vers. 3.5a) was used to calculate flow cell velocity profiles in both the

commercially available EQCM (B) and the ePEMC (C) device. Solution was examined in 2-

dimensions (2D) using Lagrange-P2P1 type elements.

EQCMFlow cell

Inlet Outlet

Inlet

OutletePEMCFlow cell

ePEMC

EQCM

B C

A

Electronic Supplementary Material (ESI) for AnalystThis journal is © The Royal Society of Chemistry 2013

Page 6: [SUPPLEMENTARY MATERIALS] Blake N. Johnson and Raj ... · Blake N. Johnson and Raj Mutharasan ∗ Department of Chemical and Biological Engineering, Drexel University, Philadelphia,

6

Figure S.4 – (A) Schematics of equivalent circuit models for ePEMC. (B) Fit of above

equivalent circuit models via the Simplex Method (Gamry Analyst Software) to ePEMC EIS

data. All models accurately capture the biosensing parameter RCT (34, 29, and 35 Ω, respective

to the order shown above). These values compared well with the semicircle distance of 34 Ω.

Best fit was obtained using the modified Randles circuit (right panel of part (A)) which contains

a constant phase element (CPE) in place of the double layer capacitance (CDL). Note both

circuits contain an infinite Warburg element (ZW) in series with the charge transfer resistance

(RCT).

0

10

20

30

40

0 50 100 150

-Im(Z

)

Re(Z)

Mod. Randles(CDL replaced with CPE)

Mod. Randles(ZW added)

Randles

RS

ZW

CDL

RCT

RS

ZW

CPE

RCT

RS

CDL

RCT

Randles Mod. Randles(ZW added)

Mod. Randles (CDLreplaced with CPE)

A

B

Electronic Supplementary Material (ESI) for AnalystThis journal is © The Royal Society of Chemistry 2013