Superconducting Quantum Interference Device

SQUID

C. P. Sun

Department of Physics

National Sun Yat Sen University

Page 2: Superconducting Quantum Interference Device

Outline

Essential mechanismof SQUID

The way to measure

Temperature controlsystem

Josephson Junction

DC AC RSO

Page 3: Superconducting Quantum Interference Device

Introduction

● Essential Mechanism

A Josephson junction is an superconductor-insulator-superconductor (SIS) layer structure placed between two electrodes

Josephson junction

Page 4: Superconducting Quantum Interference Device

DC Josephson : A dc current flows across the junction in the absence of any electric or magnetic field.

AC Josephson : A dc voltage applied across the junction causes rf current oscillations across the junction. This effect has been utilized in a precision determination of the value of Further, an rf voltage applied with the dc voltage can then cause a dc current across the junction.

e/

Macroscopic long-range quantum interference: A dc magnetic field applied through a superconducting circuit containing two junctions causes the maximum supercurrent to show interference effect as a function of magnetic field intensity. Magnetometer

Page 5: Superconducting Quantum Interference Device

DC Measurement

When the external dc field is applied to the sample, the magnetization changed with temperature will be obtained due to the spin-spin, spin-orbital and orbital-orbital effect interacting with magnetic field.

Page 6: Superconducting Quantum Interference Device

AC Measurement:

An oscillating AC magnetic field is applied to the sample. The change in flux seen by the detection circuitry is caused only by themagnetic moment of the sample as it responses the applied AC field.

Xac= dM/dH obtained from these measurement is described as having both real and imaginary components X’ and X’’ , where the imaginary component is proportional to the energy losses in the sample.

What can be derived from AC Measurement?Structure details of materials, resonance phenomena, electrical conductivity by induced currents, relaxation processes such as flux creep in SC and energy exchange between magnetic spins and the lattice in the paramagnetic materials.

Page 7: Superconducting Quantum Interference Device

Advantage of MPMS AC System

Conventional AC suceptometers measure the voltage induced

in an inductive detection coil by an oscillating AC magnetic moment.

The most common systems use mutual inductance bridge to measure the voltage induced.

These systems measure only signals with frequencies at or very near the applied excitation.

Voltage induced is proportional to the frequencies of the oscillating drive field

High pressure effect

The natural constraint

Page 8: Superconducting Quantum Interference Device

How does MPMS solve it?★ MPMS AC option combining an AC drive field with a SQUID-based detection system.

★The SQUID is an extremely sensitive flux-to-voltage converter that directly measures the change in flux as the sample moves through a superconducting detection coil coupled to the SQUID circuit.

Page 9: Superconducting Quantum Interference Device

RSO Measurement (Reciprocating Sample Option)

RSO measure a sample by moving it rapidly and sinusoidally through the SQUID pickup coil.

The option’s use of a high-quality servo motor and a digital signalprocessor (DSP) allow rapid measurement. The servo motor, unlike the stepper motor performing DC measurements, doesn’t stop sample movement for each data reading. Lock-in techniques that use the DSP reduce the contribution of low-frequency noise to the measurement.

Page 10: Superconducting Quantum Interference Device
Page 11: Superconducting Quantum Interference Device
Page 12: Superconducting Quantum Interference Device

Measure consideration of RSO

☆ Center positionTo ensure absolutely accurate measurements even when temperature drifts.

To oscillate sample through most or all of pickup coils while taking a high number of readings.

☆Maximum slope To take measurements quickly.

To move sample through small section of pickup coils.

To perform hysteresis measurement. sensitive to position

Page 13: Superconducting Quantum Interference Device

Temperature Control system

Heater

Needle Valve

Thermal meter

Page 14: Superconducting Quantum Interference Device

Thank you for attention

Sun 2005.05.18

Page 15: Superconducting Quantum Interference Device
Page 16: Superconducting Quantum Interference Device

Conclusion

Tc [Curie Temperature] Ths phase transition between paramagnetic and ferromagnetic behavior.TN [Neel’ Temperature] Ths phase transition between paramagnetic and Antiferromagnetic behavior.

Page 17: Superconducting Quantum Interference Device

Collect More Data After More Experience

More Experience can help us think more details

Page 18: Superconducting Quantum Interference Device

270 100678.22/2 cmgaussec (CGS)

(SI)215

0 100678.22/2 mteslae

The minimum value of magnetic flux Fluxon

Page 19: Superconducting Quantum Interference Device

Spin Glass Material exhibiting a high magnetic frustration and its magnetic structure is disordered even at low temperature.

Page 20: Superconducting Quantum Interference Device
Page 21: Superconducting Quantum Interference Device

Tc [Curie Temperature] Ths phase transition between paramagnetic and ferromagnetic behavior.TN [Neel’ Temperature] Ths phase transition between paramagnetic and Antiferromagnetic behavior.