super g3 fax board-q1-pm
DESCRIPTION
serviceTRANSCRIPT
Oct 26 2004
Portable Manual
FAX BoardSuper G3 FAX Board-Q1
ApplicationThis manual has been issued by Canon Inc. for qualified persons to learn technical theory, installation, maintenance, and
repair of products. This manual covers all localities where the products are sold. For this reason, there may be
information in this manual that does not apply to your locality.
CorrectionsThis manual may contain technical inaccuracies or typographical errors due to improvements or changes in products.
When changes occur in applicable products or in the contents of this manual, Canon will release technical information
as the need arises. In the event of major changes in the contents of this manual over a long or short period, Canon will
issue a new edition of this manual.
The following paragraph does not apply to any countries where such provisions are inconsistent with local law.
TrademarksThe product names and company names used in this manual are the registered trademarks of the individual companies.
CopyrightThis manual is copyrighted with all rights reserved. Under the copyright laws, this manual may not be copied,
reproduced or translated into another language, in whole or in part, without the written consent of Canon Inc.
COPYRIGHT © 2001 CANON INC.Printed in Japan
CautionUse of this manual should be strictly supervised to avoid disclosure of confidential information.
Introduction
Symbols Used
This documentation uses the following symbols to indicate special information:
Symbol Description
Indicates an item of a non-specific nature, possibly classified as Note, Caution, or Warning.
Indicates an item requiring care to avoid electric shocks.
Indicates an item requiring care to avoid combustion (fire).
Indicates an item prohibiting disassembly to avoid electric shocks or problems.
Indicates an item requiring disconnection of the power plug from the electric outlet.
Indicates an item intended to provide notes assisting the understanding of the topic in question.
Indicates an item of reference assisting the understanding of the topic in question.
Provides a description of a service mode.
Provides a description of the nature of an error indication.
Memo
REF.
Introduction
The following rules apply throughout this Service Manual:1. Each chapter contains sections explaining the purpose of specific functions and the relationship between electrical
and mechanical systems with reference to the timing of operation.
In the diagrams, represents the path of mechanical drive; where a signal name accompanies the symbol ,the arrow indicates the direction of the electric signal.
The expression "turn on the power" means flipping on the power switch, closing the front door, and closing thedelivery unit door, which results in supplying the machine with power.
2. In the digital circuits, '1'is used to indicate that the voltage level of a given signal is "High", while '0' is used toindicate "Low".(The voltage value, however, differs from circuit to circuit.) In addition, the asterisk (*) as in"DRMD*" indicates that the DRMD signal goes on when '0'.
In practically all cases, the internal mechanisms of a microprocessor cannot be checked in the field. Therefore, theoperations of the microprocessors used in the machines are not discussed: they are explained in terms of fromsensors to the input of the DC controller PCB and from the output of the DC controller PCB to the loads.
The descriptions in this Service Manual are subject to change without notice for product improvement or otherpurposes, and major changes will be communicated in the form of Service Information bulletins.All service persons are expected to have a good understanding of the contents of this Service Manual and all relevantService Information bulletins and be able to identify and isolate faults in the machine."
Contents
Contents
Chapter 1 Error Code
1.1 User Error Code................................................................................................................................................. 1- 11.1.1User Error Code........................................................................................................................................... 1- 1
1.2 Service Error Code ............................................................................................................................................ 1- 21.2.1Service Error Code ...................................................................................................................................... 1- 2
Chapter 2 Service Mode
2.1 Service Mode Table........................................................................................................................................... 2- 12.1.1Setting of Bit Switch (SSSW) ..................................................................................................................... 2- 12.1.2Setting of Menu Switch (MENU) ............................................................................................................... 2- 92.1.3Setting of Numeric Parameter (NUMERIC Param).................................................................................. 2- 112.1.4Setting of Printer Functions (PRINTER) .................................................................................................. 2- 122.1.5Initializing of Set Value (CLEAR)............................................................................................................ 2- 142.1.6Test Mode (TEST)..................................................................................................................................... 2- 152.1.7Service Report (REPORT) ........................................................................................................................ 2- 16
Chapter 3 System Construction
3.1 Basic Construction ............................................................................................................................................ 3- 13.1.1Overview ..................................................................................................................................................... 3- 13.1.2G3 Fax Controll........................................................................................................................................... 3- 1
3.2 Product Specifications....................................................................................................................................... 3- 33.2.1Product Specifications ................................................................................................................................. 3- 3
Chapter 1 Error Code
Contents
Contents
1.1 User Error Code.................................................................................................................................................. 1-11.1.1 User Error Code........................................................................................................................................... 1-1
1.2 Service Error Code ............................................................................................................................................. 1-21.2.1 Service Error Code ...................................................................................................................................... 1-2
Chapter 1
1-1
1.1 User Error Code
1.1.1 User Error Code 0007-6269
T-1-1
No. T/R Description
#001 [T] an original has jammed.
#003 [T/R] tine-out for copying or sending/receiving a single page has occurred.
#005 [T/R] time-out for initial identification (T0/T1) has occurred.
#008 [R] a mismatch of passwords at time of polling transmission has occurred.
#009 [R] recording paper has jammed or is absent.
#012 [T] recording paper is absent at the other party.
#018 [T/R] auto call initiation has failed.
#022 [T] call initiation has failed.
#037 [R] image memory overflow at time of reception has occurred.
#080 [T] the other party has no F code reception function/or is not set to receive it.
#081 [T] the other party has no password reception function/or is not to receive it.
#099 [T/R] the Stop key is pressed while a communication is under way.
#102 [T/R] a mismatch of F-code/password has occurred.
#995 [T/R] a memory communication reservation has been cancelled.
Chapter 1
1-2
1.2 Service Error Code
1.2.1 Service Error Code 0007-6271
T-1-2
No. T/R Description
##100 [T] at time of transmission, the procedural signal has been transmitted more
than specified.
##101 [T/R] the modem speed does not match that of the other party.
##102 [T] at time of transmission, fall-back cannot be used.
##103 [R] at time of reception, EOL cannot be detected for 5 sec (15 sec if CBT).
##104 [T] at time of transmission, RTN or PIN is received.
##106 [R] at time of reception, the procedural signal is received for 6 sec while in
wait for the signal.
##107 [R] at time of reception, the transmitting party cannot use fall-back.
##109 [T] at time of transmission, a signal other than DIS, DTC, FTT, CFR, or
CRP is received, and the procedural signal has been sent more than
specified.
##111 [T/R] memory error has occurred.
##114 [R] at time of reception, RTN is transmitted.
##200 [R] at time of reception, no image carrier is detected for 5 sec.
##201 [T/R] DCN is received outside the normal parity procedure.
##204 [T] DTC without transmission data is received.
##220 [T/R] system error (main program out of control) has occurred.
##223 [T/R] while a communication is under way, the line is cut.
##224 [T/R] in G3 communication, an error has occurred in the procedural signal.
##226 [T/R] the stack printer has fallen outside the RAM area.
##229 [R] the recording unit has remained locked for 1 min.
##232 [T] encoding error has occurred.
##237 [R] decoding error has occurred.
##238 [R] the print control unit is out of order.
##261 [T/R] system error has occurred.
##280 [T] at time of transmission, the procedural signal has been transmitted more
than specified.
##281 [T] at time of transmission, the procedural signal has been transmitted more
than specified.
##282 [T] at time of transmission, the procedural signal has been transmitted more
than specified.
##283 [T] at time of transmission, the procedural signal has been transmitted more
than specified.
##284 [T] at time of transmission, DCN is received after transmission of TCF.
##285 [T] at time of transmission, DCN is received after transmission of EOP.
##286 [T] at time of transmission, DCN is received after transmission of EOM.
##287 [T] at time of transmission DCN is received after transmission of MPS.
##288 [T] after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or
RTN has been received.
##289 [T] after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or
RTN has been received.
##290 [T] after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or
RTN has been received.
##670 [T] at time of V.8 late start, the V.8 ability of DIS front the receiving party
is expected to be detected, and the CI signal is expected to be
transmitted in response; however, the procedure fails to advance, and
the line is released because of T1 time-out.
##671 [R] at time of V.8 arrival, procedure fails to move to phase 2 after detection
of CM signal from caller, causing T1 time-out and releasing line
##672 [T] at time of V.34 transmission, a shift in procedure from phase 2 to phase
3 and thereafter stops, causing the machine to release the line and suffer
T1 timeout.
##673 [R] at time of V.34 reception, a shift in procedure from phase 2 to phase 3
and thereafter stops, causing the machine to release the line and suffer
T1 timeout.
##674 [T] at time of V.34 transmission, a shift in procedure from phase 3 and
phase 4 to the control channel and thereafter stops, causing the machine
to release the line and suffer T1 timeout.
##675 [R] at time of V.34 reception, a shift in procedure from phase 3 and phase
4 to the control channel and thereafter stops, causing the machine to
release the line and suffer T1 timeout.
##750 [T] at time of ECM transmission, no meaningful signal is received after
transmission of PPS-NULL, causing the procedural signal to be
transmitted more than specified.
##752 [T] at time of ECM transmission, DCN is received after transmission of
PPS-NULL.
No. T/R Description
##753 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-NULL, or T5
time-out (60 sec) has occurred.
##754 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-NULL.
##755 [T] at time of ECM transmission, no meaningful signal is received after
transmission of PPS-MPS, causing the procedural signal to be
transmitted more than specified.
##757 [T] at time of ECM transmission, DCN is received after retransmission of
PPS-MPS.
##758 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-MPS, or T5
time-out (60 sec) has occurred.
##759 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-MPS.
##760 [T] at time of ECM transmission, no meaningful signal is received after
transmission of PPS-EOM, causing the procedural signal to be
transmitted more than specified.
##762 [T] at time of ECM transmission, DCN is received after transmission of
PPS-EOM.
##763 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-MPS, or T5
time-out (60 sec) has occurred.
##764 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-EOM.
##765 [T] at time of ECM transmission, no meaningful signal is received after
transmission of PPS-EOP, causing the procedural signal to be
transmitted more than specified.
##767 [T] at time of ECM transmission, DCN is received after transmission of
PPS-EOP.
##768 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-EOP, or T5
time-out (60 sec) has occurred.
##769 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of PPS-EOP.
##770 [T] at time of ECM transmission, no meaningful signal is received after
transmission of EOR-NULL, causing the procedural signal to be
transmitted more than specified.
No. T/R Description
##772 [T] at time of ECM transmission, DCN is received after transmission of
EOR-NULL.
##773 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of EOR-NULL, or
T5 time-out (60 sec) has occurred.
##774 [T] at time of ECM transmission, ERR is received after transmission of
EOR-NULL.
##775 [T] at time of ECM transmission, no meaningful signal is received after
transmission of EOR-MPS, causing the procedural signal to be
transmitted more than specified.
##777 [T] at time of ECM transmission, DCN is received after transmission of
EOR-MPS.
##778 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission EOR-MPS, or T5
time-out (60 sec) has occurred.
##779 [T] at time of ECM transmission, ERR is received after transmission of
EOR-MPS.
##780 [T] at time of ECM transmission, no meaningful signal is received after
transmission of EOR-EOM, causing the procedural signal to be
transmitted more than specified.
##782 [T] at time of ECM transmission, DCN is received after transmission of
EOR-EOM.
##783 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of EOR-EOM, or T5
time-out (60 sec) has occurred.
##784 [T] at time of ECM transmission, ERR is received after transmission of
EOR-EOM.
##785 [T] at time of ECM transmission, no meaningful signal is received after
transmission of EOR-EOP, causing the procedural signal to be
transmitted more than specified.
##787 [T] at time of ECM transmission, DCN is received after transmission of
EOR-EOP.
##788 [T] at time of ECM transmission, the procedural signal has been
transmitted more than specified after transmission of EOR-EOP, or T5
time-out (60 sec) has occurred.
##789 [T] at time of ECM transmission, ERR is received after transmission of
EOR-EOP.
##790 [R] at time of ECM reception, ERR is transmitted after transmission of
EOR-Q.
No. T/R Description
##791 [T/R] while ECM mode procedure is under way, a signal other than a
meaningful signal is received.
##792 [R] at time of ECM reception, PPS-NULL cannot be detected over partial
page processing.
##793 [R] at time of ECM reception, no effective frame is received while high-
speed signal reception is under way, thus causing time-out.
##794 [T] at time of ECM reception, PPR with all 0s is received.
##795 [T/R] a fault has occurred in code processing for communication.
##796 [T/R] a fault has occurred in decoding processing after reception of ECM
No. T/R Description
Chapter 2 Service Mode
Contents
Contents
2.1 Service Mode Table............................................................................................................................................ 2-12.1.1 Setting of Bit Switch (SSSW) ..................................................................................................................... 2-12.1.2 Setting of Menu Switch (MENU) ............................................................................................................... 2-92.1.3 Setting of Numeric Parameter (NUMERIC Param).................................................................................. 2-112.1.4 Setting of Printer Functions (PRINTER) .................................................................................................. 2-122.1.5 Initializing of Set Value (CLEAR)............................................................................................................ 2-142.1.6 Test Mode (TEST)..................................................................................................................................... 2-152.1.7 Service Report (REPORT) ........................................................................................................................ 2-16
Chapter 2
2-1
2.1 Service Mode Table
2.1.1 Setting of Bit Switch (SSSW) 0007-5751
T-2-1
SSS
W-
SW
Bit Function 1 0 Detailed Discussions
1 0 service error codeout
put
not
out
put
Selects whether or not service error
codes are output.
When output is selected, service error
codes are displayed and in reports.
1 error dump listout
put
not
out
put
Selects whether or not error dump lists
are output.
3 1echo protect tone at high-
speed transmission
tra
ns
mit
do
not
tra
ns
mit
Use it to enable/disable transmission of
an echo protect tone for a high-speed
transmission V.29 modem signal
(transmission speed at 9600 or 7200
bps).
If errors occur frequently at time of
transmission because of the condition
of the line, select 'transmit' so that a
non-modulation carrier will be
transmitted as a pre-image
transmission sync signal for about 200
msec.
Memo: Any of the following error
codes may be indicated because of the
line condition at time of transmission
##100, ##104, ##281, ##283, ##750,
##755, ##760, ##765
4
transmission mode:
international transmission
(1)
use
do
not
use
5
transmission mode:
international transmission
(2) or (3)
use
do
not
use
Chapter 2
2-2
Detailed Discussions of Bits 4, 5, and 6Use it to select an appropriate transmission mode: international transmission (1), international transmission (2), orinternational transmission (3).Use the service soft switch or the dial registration function to select the appropriate transmission mode if errors occurfrequently at time of transmission to overseas.Memo: Any of the following error codes may be indicated because of an echo at time of transmission##005, ##100, ##101, ##102, ##104, ##201, ##280, ##281, ##283, ##284, ##750, ##760, ##765, ##774, ##779,##784, ##794Using the Dial Recognition Function (user level):Select 'international transmission (1)' when making an entry in the Address Book. If errors still occur, select'international transmission (2)' and then 'international transmission (3)' in sequence until errors stop. Thetransmission mode selected using the One-Touch Dial function or the Speed Dial function will be give priority overthe setting made by the service soft switch.An international transmission mode may be selected using the keypad if a mode has been selected using this switch;for settings, see the following table:
6 transmission mode
int
ern
ati
on
al
tra
ns
mi
ssi
on
(3)
int
ern
ati
on
al
tra
ns
mi
ssi
on
(2)
7tonal signal before CED
signal transmission
tra
ns
mit
do
not
tra
ns
mit
Use it to enable/disable transmission of
a 1080-Hz tonal signal before
transmission of the CED signal.
Select 'transmit' if errors occur
frequently because of an echo when
reception is from overseas.
Memo: Any of the following error
code may be indicated because of an
echo at time of reception
##005, ##101, ##106, ##107, ##114,
##200, ##201, ##790
SSS
W-
SW
Bit Function 1 0 Detailed Discussions
Chapter 2
2-3
T-2-2
International transmission (1): select it to ignore the first DIS signal from the other party.International transmission (2): select it to transmit a 1850-Hz total signal when transmitting the DIS signal.International transmission (3): select it to transmit a 1650-Hz total signal when transmitting the DIS signal.
T-2-3
Transmission mode Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
International transmission 1 * 0 0 1 0 0 * 0
International transmission 2 * 0 1 0 0 0 * 0
International transmission 3 * 1 1 0 0 0 * 0
SSS
W-
SW
Bi
tFunction 1 0 Detailed Discussions
4 2the number of final flag
sequences of protocol signals2 1
Use it to select the number of last
flag sequences for a protocol
signal (transmission speed at 300
bps). Select '2' if the other party
fails to receive the protocol
signal properly.
Memo: Any of the following
error codes may be indicated at
time of transmission
##100, ##280, ##281, ##750,
##753, ##754, ##755, ##758,
##759, ##760, ##763 ##764,
##765, ##768, ##769,##770,
##773, ##775, ##778, ##780,
##783, ##785, ##788
3Reception mode after CFR
signal transmission
high
spee
d
high
spee
d/
low
spee
d
Use it to select an appropriate
reception mode after
transmission of the CFR signal.
If errors occur frequently at time
of reception because of the
condition of the line, select 'high
speed' for reception mode and, at
the same time, selects 'do not
receive' for 'ECM reception.'
Memo: Any of the following
error codes may be indicated at
time of reception because of line
condition
##107, ##114, ##201
Be sure to change bit 4 before
changing this bit; if errors still
occur, change this bit.
When 'high speed' is selected,
only high-speed signals (images)
will be received after
transmission of the CFR signal.
4
the length of the period of
ignoring low speed signals
after CFR output
1500
ms
700
ms
Use it to select the time length
during which low-speed signals
are ignored after transmission of
the CFR signal.
If the condition of the line is not
good and, therefore, the
reception of image signals is
difficult, select '1500 ms.'
5 1Conversion from mm to inch
(text mode)
conv
ert
do
not
conv
ert
Use it to enable/disable
millimeter/inch conversion in
sub scanning direction for
images read in text mode.
2Conversion from mm to inch
(text/photo mode)
conv
ert
do
not
conv
ert
Use it to enable/disable
millimeter/inch conversion in
sub scanning direction for
images read in text/photo mode
while bit 1 is set to '1'.
SSS
W-
SW
Bi
tFunction 1 0 Detailed Discussions
Chapter 2
2-5
The machine will stop the ongoing communication if the transmission/reception of a single original page takes 32min or more. To use the timer for a purpose other than this function, refer to the tables that follow, and select anappropriate time length.When 'do not enable' is selected using bit 7, the time-out length for a single page for all modes will depend on thesetting of bit 0 and bit 1.
3 end DIS signal bits 33 and overproh
ibit
do
not
proh
ibit
Use it to enable/disable
transmission of bit 33 and
thereafter (DIS signal).
If 'prohibit' is selected, the Super
Fine reception function or
Memory Box function cannot be
used for communications from
non-Canon machines.
4
Recording paper length
availability declared in DIS
signal
A4/
B4
size
any
size
Use it to enable/disable
declaration of the use of cut
sheets (DIS signal).
For reception of an extra-long
original, select 'A4/B4 size' if
division is to be by the other
party.
Memo: Some machines are not
designed to divide extra-long
originals.
12 0Time-out period for one page
upon transmission1 0
1Time-out period for one page
upon transmission1 0
2Time-out period for one page
upon (HT transmission)1 0
3Time-out period for one page
upon (HT transmission)1 0
4Time-out period for one page
upon reception1 0
5Time-out period for one page
upon reception1 0
7
Respective page timer settings
for transmission and for
reception
enab
le
do
not
enab
le
SSS
W-
SW
Bi
tFunction 1 0 Detailed Discussions
T-2-4
Time-Out Length for Transmission/
Reception
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
8 min 0 * * * * * 0 0
16 min 0 * * * * * 0 1
32 min 0 * * * * * 1 0
64 min 0 * * * * * 1 1
Time-Out Length for Transmission (in text
mode)
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
8 min 1 * * * * * 0 0
16 min 1 * * * * * 0 1
32 min 1 * * * * * 1 0
64 min 1 * * * * * 1 1
Time-Out Length for Transmission (image
mode other than text mode)
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
8 min 1 * * * 0 0 * *
16 min 1 * * * 0 1 * *
32 min 1 * * * 1 0 * *
64 min 1 * * * 1 1 * *
Time-Out Length for ReceptionBit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
8 min 1 * 0 0 * * * *
16 min 1 * 0 1 * * * *
32 min 1 * 1 0 * * * *
64 min 1 * 1 1 * * * *
T-2-5
SSS
W-
SW
Bi
tFunction 1 0 Detailed Discussions
14 2direction of scanning for inch/mm
conversion
bot
h
ma
in
an
d
su
b
sca
nni
ng
dir
ect
ion
s
su
b
sca
nni
ng
dir
ect
ion
onl
y
Use it to specify whether to
convert or not convert an inch-
configuration resolution into a
millimeter-configuration
resolution for image read in G3
transmission: either in sub
scanning direction only or in
both main and sub scanning
directions. The setting is valid
only when bit 1 of SW05 of #1
SSSW is set to '1'.
4inch-configuration resolution
declaration
de
cla
re
do
not
de
cla
re
Use it to specify whether to
declare or not declare an inch-
configuration resolution to the
other machine for G3
communication: if 'declare' is
selected, the machine will
indicate that it reads and
records at an inch-
configuration resolution using
the DIS, DCS, or DTC signal.
25 0transmission telephone number
indicated report
oth
er
par
ty'
s
cal
ler'
s
Use it to select the transmission
telephone number indicated on
the report at the end of
transmission.
caller's number: indicates the
telephone number of the caller
on the report.
number of other party:
indicates the telephone number
(CSI signal data) sent from the
other part on the report.
26 2confirmation screen for
broadcasting
dis
pla
y
do
not
dis
pla
y
Use it to enable/disable
indication of a confirmation
message before broadcasting in
consideration of a mistake
during input of addresses.
7error report at time of transmission
suspension
do
not
ge
ner
ate
ge
ner
ate
Use it to enable/disable
generation of an error report in
response to a press on the Stop
key to suspend transmission.
28 0 Caller V.8 protocolN
O
Y
ES
Select whether to use the V.8
protocol when calling. If NO is
selected, the V.8 protocol is
inhibited at calling and the
V.21 protocol is used.
1 Called party V.8 protocolN
O
Y
ES
Select whether to use the V.8
protocol when called. If NO is
selected, the V8 protocol is
inhibited when called and the
V.21 protocol is used.
2 Caller V.8 protocol late startN
O
Y
ES
If ANSam signal is not
received during transmission,
select whether to use the V.8
protocol when the other fax
machine declares the V.8
protocol in DIS signal. If NO is
selected, the CI signal is not
transmitted and the V.8
protocol is not used even if the
DIS that specifies the V.8
protocol is received.
3 Called party V.8 protocol late startN
O
Y
ES
Select whether to declare the
V.8 protocol in DIS signal for
reception. If NO is selected, the
V.8 protocol cannot be used
because it is not declared in
DIS signal.
SSS
W-
SW
Bi
tFunction 1 0 Detailed Discussions
Chapter 2
2-9
2.1.2 Setting of Menu Switch (MENU) 0007-5755
T-2-6
4 V.34 reception fallback
Pr
ohi
bit
ed
No
t
pr
ohi
bit
ed
Select whether the receiver
falls back during V.34
reception. If 'Prohibit' is
selected, the receiver does not
fall back.
5 V.34 transmission fallback
Pr
ohi
bit
ed
No
t
pr
ohi
bit
ed
Select whether the transmitter
falls beck during V.34
transmission. If 'Prohibit' is
selected, teh transmitter does
not fall back.
No
.Function Range of settings
00
5NL equalizer
Use it to enable-disable the NL equalizer.
If errors occur often during
communication because of the condition
of the line, enable (ON) the NL equalizer.
Memo:
Any of the following error codes may be
indicated at time of transmission because
of the line condition
##100, ##101, ##102, ##104, ##201,
##281, ##282, ##283,
##750, ##755, ##765, ##774, ##779,
##784, ##789
Any of the following error codes may be
indicated at time of transmission because
of the line condition
##103, ##107, ##114, ##201, ##790,
##793
1: ON, 0: OFF
SSS
W-
SW
Bi
tFunction 1 0 Detailed Discussions
00
6
telephone line
monitor
Use it to the telephone line monitor
function:
0(DIAL): generate the monitor sound of
the telephone line using the speaker from
the start of transmission to DIS.
1: generate the monitor sound of the
telephone line using the speaker from the
start of communication to the end of it.
3: do not generate the monitor sound of the
telephone line usng the speaker.
from 0 to 3
00
7
transmission level
(ATT)
Use it to set the transmission level (ATT).
Raise the transmission level if errors occur
frequently at time of communication
because of the condition of the line. (It
means close to 8)
Memo:
Any of the following error codes may be
indicated at time of transmission because
of the line condition
##100, ##101, ##102, ##104, ##201,
##280, ##281, ##282,
##283, ##284, ##750, ##752, ##754,
##755, ##757, ##759,
##760, ##762, ##764, ##765, ##767,
##769, ##770, ##772,
##774, ##775, ##777, ##779, ##780,
##782, ##784, ##785,
##787, ##789
Any of the following error codes may be
indicated at time of reception because of
the line condition
##103, ##106, ##107, ##201, ##793
from 8 to 15 (ex:
15= -15 dBm)
00
8
V.34 modulation
speed upper limit
Use it to set an upper limit to the
modulation speed (baud rate) for the V.34
primary channel.
0:3429, 1:3200,
2:3000, 3:2800,
4:2743, 5:2400
00
9
V34 data speed upper
limit
Use to set an upper limit to the data
transmission speed for the V.34 primary
channel between 2.4K and 33.6K bps in
increments of 2400 bps. (0: 2.4K to 13:
33.6K bps).
from 0 to 13
No
.Function Range of settings
Chapter 2
2-11
2.1.3 Setting of Numeric Parameter (NUMERIC Param) 0007-5757
T-2-7
No. FunctionRange of
settings
002RTN transmission
condition (1)
Use it to set RTN signal transmission conditions.
Raise these parameters for more lenient conditions if
errors occur frequently at time of reception because
of transmission of the RTN signal.
Memo:
Any of the following error codes may be indicated at
time of reception because of RTN signal
transmission
##104, ##107, ##114, ##201
RTN signal transmission condition (1) affects the
ratio of error lines to the total number of lines per
single page of received images.
RTN signal transmission condition (2) affects the
standard value (*2) of burst errors (*1).
RTN signal condition (3) affects the number of errors
not reaching the standard value of burst errors.
*1: transmission error occurring cover several lines.
*2: for instance, if '15' is set, a single burst error will
represent an error occurring continuously cover 15
lines.
If any of these lines is detected while an image signal
is being received, the RTN signal will be transmitted
after receiving the protocol signal of the transmitting
party. Higher parameters
1% to 99%
003RTN transmission
condition (2)
2 to 99
times
004RTN transmission
condition (3)
1 to 99
lines
005NCC pause time
(before ID code)
Use it to set the length of the pause automatically
entered between access code and ID code when the
NCC (New Common Carrier) line is used for dialing.
1 to 60 sec
006NCC pause time
(after ID code)
Use it to set the length of the pause automatically
entered between ID code and telephone number of
the other party when the NCC (New Common
Carrier) line is used for dialing.
1 to 60 sec
007pre-pause time at
time of placing call
Use it to set the length of the pause used when placing
a call.
0 to 9999
(x10ms)
Chapter 2
2-12
2.1.4 Setting of Printer Functions (PRINTER) 0007-5758
T-2-8
009
number of
characters in
telephone numbers
between
transmitting and
receiving parties
Use it to set the number of TSI comparison characters
(lower $ characters) for a check on telephone
numbers.
0 to 20
characters
010line connection
identification time
Use it to set the time for identifying the line
connection. Raise this parameter if errors occur
frequently at time of communication because of the
condition of the line.
Memo: Any of the following error codes may be
indicated because of the condition of the line
##005, ##018
The line condition identification time is between
when the dial signal is transmitted and when the line
condition is cut for the transmitting party, while it is
between when the DIS signal is transmitted and when
the line is cut for the receiving party.
0 to 9999
(10ms)
011T.30 T1 timer (for
reception)
Set it so that the T1 time may be varied. (The
regulations governing the T1 timer vary from country
to country (PTT)).
0 to 9999
(10ms)
013 T30. EOL timer
Set it so that the 1-line transmission time is longer for
reception to prevent reception errors caused by a long
data length per line (e.g., computer FAX).
500 to 3000
(10ms)
027
preamble detection
time for V21 low-
speed flag
Use it to detect the time of detection after which
command analysis is started after detecting V.21
low-speed command preambles continuously for a
specific period of time.
20 (x10ms)
SSS
W-
SW
Bi
tFunction 1 0
05 0 priority on LTR placedo not
place
1 priority on LGL placedo not
place
No. FunctionRange of
settings
Chapter 2
2-13
Detailed Discussions of Bits 0 and 1Use it to enable/disable placement of priority on LTR paper when an image that may be printed at 100% or in evendivision on A4, LTR, or LGL is received.The setting of bit 0 and bit 1 affects the order of priority as follows:
T-2-9
However, when priority is on recording in sub scanning direction, the order will be as follows even when bit 1 andbit 0 are set to '0': LTR -> A4 -> LGL.Detailed Discussions of Bit 7Use it to enable/disable placement of priority on recording in sub scanning direction.place: if B4 recording paper and A4 recording paper are set and an A4 extra-long image (*) is received, printing willbe on the B4 recording paper. do not place: if B5 horizontal recording paper and A4 recording paper are set and a B4 image is received, printingwill be by division and on B5 horizontal recording paper. *: Image B4 or shorter and that cannot be printed by division and on A4 recording paper.
7 priority on recording in sub scanning direction placedo not
place
Bit1 Bit0 Priority of recording paper
0 0 A4 -> LTR -> LGL
0 1 LTR -> A4 -> LGL
1 0 LGL -> LTR -> A4
1 1 LTR -> LGL -> A4
SSS
W-
SW
Bi
tFunction 1 0
Chapter 2
2-14
T-2-10
Numerical Parameter Composition
T-2-11
2.1.5 Initializing of Set Value (CLEAR) 0007-5759
You can select and initialize data by making the following selections; as a result, settings and various parametervalues will be reset to the factory settings.
SSS
W-
SW
Bi
tFunction 1 0
Detailed
Discussions
6 5 reduced printing from A4 to B5 enable disable
Use it to force
printing on B5 by
reduction (of A4
received image).
Setting this bit will
cause all A4
reports to be
printed in B5 by
division.
N
o. Function
Setting
range
Initial
settingUnit
01
Missing areas of printing image when receiving image
with longer length than standard
Use it to set the range of the image to be removed from
when printing an extra-length received image.
Lower the parameter to decrease the range if the
trailing edge of the received image must be retained (as
when it is longer than the effective recording length).
0 to 9999 12 1mm
04
Leading edge blank area
Use it to set the leading-edge margin for the effective
recording length.
0 to 9999 3 1mm
05
Trailing edge blank area
Use it to set the trailing-edge margin for the effective
recording length.
0 to 9999 3 1mm
Chapter 2
2-15
T-2-12
*1: If the model is capable of storing addresses other than fax addresses, the telephone number data will not bedeleted upon execution of 'TEL' and 'ALL'. To remove the telephone number data, use the host machine's servicemode: COPIER>FUNCTION>CLEAR>ADRS-BK.*2: When 'ALL' is executed, the values suited to the destination of the machine will be stored under 'TYPE'; in thecase of Japan, 'standard'.
2.1.6 Test Mode (TEST) 0007-5762
T-2-13
Item Data to be initialized
TEL telephone number registration data (*1)
USER SW
user data and data registered under SSSW #1 through #3.
of user data, the memory management data will not be deleted.
image data collected in memory will not be deleted.
SERVICE
SW user data and data in SSSW #1 through #3, #7.
NCU data under SSSW#4.
SERVICE
DATA system dump list data.
REPORT communication control report data.
ALL all settings/registered data (*1) except data under #5 TYPE (*2).
COUNTER number of prints, number of sheets read.
Level 1 Level 2 Super G3 Fax Board present
MODE
MRELAY-1 yes
RELAY-2 no
FREQ yes 'RBT' is not currently supported.
G3TXyes '300-ALL0' through '300-4:1' are not currently
supported.
DTMFTX yes 'SHORT' is not currently supported.
TONERX no
V34G3TX yes
FACU
LTYG34800TX yes
Chapter 2
2-16
Do not use items in the table identified as "no."
2.1.7 Service Report (REPORT) 0007-5764
F-2-1
*1: RX, number of total pages received; TX, number of total pages sent.*2: number of pages sent/received according to original size.*3: number of pages sent/received in connection with different modem speeds (Standard, Fine, Super Fine, UltraFine).*4: number of pages sent/received in connection with different modes.*5: number of pages sent/received in connection with different coding methods.*6: number of transmissions/receptions according to mode.*7: number of occurrences according to error code.
SPEAKER no
LINE DETECT1 no
LINE DETECT2 no
LINE DETECT3 no
VOICETX no
DATA SET no
ISDNMOD no
ISDNMOD2 no
Level 1 Level 2 Super G3 Fax Board present
������ ��
����� �� � ���� ����� �� �����
� ����
�� � ���� �� � �� �� � �� � � � � ��� � �
� � ����
�� � ���� �� � �� �� � �� � � � � ��� � �
����� � � ����� � � ����� � ���� ����� � � ����� � �
����� � � ����� � � ����� � � ����� � � ����� � �
���� � � ���� � � ���� � � ���� � �
����� � �� ����� � � ����� � � ����� � �
����� � � ����� � �
���� � � ���� � � ���� � � ���� � �
� � � �� ���� � ���� ����� � ��� �� �� � ��
! � � � � �� � � � "��� � ���� "��� � �
�� � �� �� � ���� �� � �
###############################
### �$� � �� � ��� ###
###############################
���� ����� �� ����� �� ���
%��� � � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � � � � � �
� � � �� � � � �
� � � � � � � �
%��� � � � � � � �� �
� � � � � � � �
�
%��� � �� � � � �
#�
#�
#�
#�
#�
#�
#�
#�
#�
Chapter 2
2-17
F-2-2
*1: service error code.*2: START TIME, date and time (in 24-hr notation).*3: OTHER PARTY, telephone number sent by the other party.*4: MAKER CODE, manufacturer code.*5: MACHINE CODE, model code.*6: bit 1 through bit 96 of DIS, DCS, or DTC that has been received.*7: bit 1 through bit 96 of DIS, DCS, or DTC that has been transmitted.*8: RX, procedural signal received; TX, procedural signal transmitted.
��
��
��
������
��
��
�� ��� �� ��� ���
�� �� �� ��� �
� � �� ����� ��� ��� � ��� ��� �� ��������� ����� �!�� ��� �� ��"� �!�� �� � � # #$� ������ � �� �� !� � �� � ���%�� �� �� ���� &'()� !� � �� ��� ��� &*+ ,#$ ��-� � �#� ��!� ��"� � ��� �% �!��� � ��� �� �%�� � ��� �� ��%��
� �. � / &01 � 2� � ������ ������ ��� � ���� � / &01 �� 2� / &01 �� 2� � � � / &01 �� 2� . � / &01 � 2� �� ����� �� � � � / &01 �� 2� / &01 �� 2� � � � / &01 �� 2
�
�. � "�� �� !�� �� � � � �
. � "�� �� ! � ���3��� ���3"�� ���3��� ���3"�� ���3��� ���3"��
�. � � � � � � �
. � ���3��� ���3"�� ���3��� ���3��� ! "
������ �
� � �� ����� ��� ���� � ��� ��� �� ��������� ����� �!�� ��� �� ��"� �!�� �� � � # #$� ������ � �� �� !� � �� � ���%�� �� �� ���� &'()� !� � �� ��� ��� &*+ ,#$ ��-� � �#� ��!� ��"� � ��� �% �!��� � ��� �� �%�� � ��� �� ��%��
� �. � / &01 � 2� � ������ ������ ��� � ���� � / &01 �� 2� / &01 �� 2� � � � / &01 �� 2� . � / &01 � 2� �� ����� �� � � � / &01 �� 2� / &01 �� 2� � � � / &01 �� 2
�. � "�� �� !�� �� � � � �
. � "�� �� ! � ���3��� ���3"�� ���3��� ���3"�� ���3��� ���3"��
�. � � � � � � �
. � ���3��� ���3"�� ���3��� ���3��� ! "
�� ��!�� ��� �
� � �� ����� ��� ��� � ��� ��� �� ��������� ����� �!�� ��� �� ��"� �!�� �� � � # #$� ������ � �� �� !� � �� � ���%�� �� �� ���� &'()� !� � �� ��� ��� &*+ ,#$ ��-� � �#� ��!� ��"� � ��� �% �!��� � ��� �� �%�� � ��� �� ��%��
��
Chapter 3 System Construction
Contents
Contents
3.1 Basic Construction ............................................................................................................................................. 3-13.1.1 Overview ..................................................................................................................................................... 3-13.1.2 G3 Fax Controll........................................................................................................................................... 3-1
3.2 Product Specifications........................................................................................................................................ 3-33.2.1 Product Specifications ................................................................................................................................. 3-3
Chapter 3
3-1
3.1 Basic Construction
3.1.1 Overview 0007-5876
The board is designed to enable a digital copier to serve as a high-performance multi-functional machine (imageprocessing functions and communication functions over the telephone line).It is capable of communicating at a maximum rate of 33.6 kbps, thanks to the presence of a V.34-compliant modem(ITU-T).
F-3-1
[1] Super G3 Fax Board-Q1[2] Speaker unit
3.1.2 G3 Fax Controll 0007-6207
FAX modem control is done by the controller in this model while it is done by the FAX board in the existing models.
[1]
[2]
F-3-2
MODEM NCU
Fax controlprogram
LINE
Controller
Chapter 3
3-3
3.2 Product Specifications
3.2.1 Product Specifications 0007-6045
T-3-1
Item Description
Communication G3
Line type Subscriber line (PSTN)
Modulation <G3 image signal>
ITU-T V.27ter (2.4Kbps, 4.8Kbps)
ITU-T V.29 (7.2Kbps, 9.6Kbps)
ITU-T V.17 (TC 7.2Kbps, TC 9.6Kbps, 12Kbps, 14.4Kbps)
ITU-T V.34 (2.4Kbps, 4.8Kbps, 7.2Kbps, 9.6Kbps, 12Kbps, 14.4Kbps, 16.8Kbps, 19.2Kbps, 21.6Kbps, 24Kbps, 26.4Kbps, 28.8Kbps, 31.2Kbps, 33.6Kbps)
<G3 procedure signal>
ITU-T V.21 No.2 (300bps)
ITU-T V.8, V.34 (300bps)
Transmission speed 33.6Kbps, 31.2Kbps, 28.8Kbps, 23.4Kbps, 24Kbps, 21.6Kbps, 19.2Kbps, 16.8Kbps, 14.4Kbps, 12Kbps, TC 9.6Kbps, TC7.2Kbps, 9.6Kbps, 7.2Kbps, 4.8Kbps, 2.4Kbps
auto fallback function
Coding method JBIG, MMR, MR, MH
G3-specific abridged procedure
no
Dial Tone Detection yes
Modem IC conexant FM336 Plus
Error correction ITU-T ECM
Transmission original size
A3, A4, A4R, A5, A5R, B4, B5, B5R, LTR, LTRR, LGL, 11x17, STMT, STMTR
ADF: double-sided originals accepted
Scanning line density Standard (200 x 100 dpi): 8 dots/mm x 3.85 lines/mm
Fine (200 x 200 dpi):8 dots/mm x 7.7 lines/mm
Super Fine (300 x 300 dpi): 8 dots/mm x 15.4 lines/mm
Ultra Fine (400 x 400 dpi): 16 dots/mm x 15.4 lines/mm
Halftone 256 gradations
Recording unit maximum reception size: A3 (297mm x 420mm)
scanning line density: 600dpi x 600dpi
Memory image memory: 3700 prints (Canon Fax Standard Chart No. 1)
memory type: hard disk (image area of 6.4 GB)
storage: JBIG
Extension telephone connection
no
Answering machine connection
no
Fax/Tel switch-over no
Quick Direct Transmission
yes
Divided Transmission yes
Transmission Header(Add Remote Name on Header SW)
yes
Remote reception no
Polling (F code) no
Memory box yes
Password reception yes
Machine telephone No. transmission
yes
Item Description
User abbreviation transmission
yes
Dual access 64 (maximum number of reservations)
Broadcasting 256 targets (maximum number of targets)
64 target(maximum number of targets by 10 key dialing)
Item Description
Oct 26 2004