substation clamp - preformed line products€¦ · substation clamp. standard terms and conditions...

26
Product Catalogue Substation Clamp

Upload: others

Post on 21-Oct-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

  • Product Catalogue

    Substation Clamp

  • Standard Terms and Conditions of Business1. Application of ConditionsThese terms and conditions shall govern and control all offers and sales by PREFORMEDTM LINE PRODUCTS (SOUTH AFRICA) (PTY) LTD. (herein called

    “the company”). Unless expressly accepted in writing signed at its head office in Pietermaritzburg by an authorised signatory, any qualification of these

    conditions in a customer’s order or enquiry, or anything contrary to or conflicting with any of these conditions shall be treated as inapplicable and of no effect.

    2. AcceptanceAny tender or quotation by the company only applies for thirty days from date thereof; and no order shall bind the company until the customer shall receive

    written confirmation thereof from the company, duly signed on behalf of the company.

    3. PricesAll prices are nett, F.O.R. Works at Pietermaritz burg and subject to change without notice. Value Added Tax (VAT) is not included and will be added-on where

    applicable.

    4. Financial ResponsibilityThe Buyer’s financial responsibility is at all times subject to approval of the company’s credit department and the company at any time may require payment

    in advance for a satisfactory security or guarantee that invoices will be paid promptly when due. If the Buyer fails to comply with any term of payment, the

    company reserves the right to withhold further deliveries or to termi nate the agreement and any unpaid amount thereupon shall become due immediately.

    5. Terms of PaymentNet 30 days from date of the company’s invoice.

    6. DeliveryThe company will use its best endeavours to deliver the goods by the time fixed for delivery, but if from any cause other than the wilful default of the company

    delivery is delayed, the company will not be responsible for any loss or damage thereby caused to the Buyer. Failure of one delivery shall not vitiate the

    contract as to others. No responsibility is accepted for delays due to loss in manufacturing or for damage and/or other delays due to Act of God, War, Fire,

    Civil Commotion, Accidents, and for other causes beyond control. Offers of delivery from stock are subject to the fitting being unsold on receipt of order.

    7. Delivery ChargesUnless otherwise agreed or stated, delivery charges are for customer’s account.

    8. WarrantyWe warrant all goods manufactured and supplied by us are in accordance with our standard proprietary specifications and designs, and that products are fit for

    the ordinary purposes for which they are manufactured and when installed to our recommended procedures. In the event of product malfunction, our liability

    will be limited to the free replacement only of our defective products provided such malfunction is proved to be directly attributable to defective materials or

    workmanship and subject to a claim in such event being received by us in writing within 90 (ninety) days after receipt of such goods by our customer.

    9. PackingAll goods are packed in our standard corrugated cartons, wooden crates and/or suitable alternatives at the company’s discretion.

    10. Loss or Damage in TransitThe company is not responsible for this risk. In the case where the company has accepted transit risk in terms of clause 1 of these conditions, transit loss or

    damage must be reported by the customer or consignee immediately in writing to the carrier, and also to the company. Documentary evidence, as prescribed

    by the CARRIERS must be given by the consignee to the company within seven days of receipt of the consignment in question.

    11. Testing and InspectionWhen testing and inspection is specified by customers, this shall be carried out at the company’s Works in a suitable area designated by the company.

    12. Deviations in Quantities ManufacturedGoods manufactured are subject to a deviation of plus or minus 10% in quantity.

    13. Standard PacksThe company reserves the right to supply in increments of its standard packs.

    14. CancellationThe Buyer shall not be able to cancel any order for delay in delivery or other cause until written notification of such intention has been received by the company.

    In any event the Buyer shall be obligated to accept and pay for any goods previously despatched to order, and to pay cancellation charges based on expenses

    incurred or commitments made by the company for any goods which are in the process of manufacture.

    15. ReturnsNo materials shall be returned without our prior written authorisation. Only non-obsolete standard items in original cartons may be returned. Carriage must

    be prepaid. Requests for return must be instituted within 90 days of original delivery and returns will be subject to factory inspection before acceptance and

    credit authorisation. We reserve the right to apply a minimum servicing charge of 15% of the invoice amount.

    16. SpecificationsIn pursuance of our policy of continuous research and development we reserve the right to change specifications without prior notice.

    17. DisclaimerPLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the

    information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 1SublignTM

    SUBSTATION CLAMPSIndexOutline Specifications and Service conditions .................................................................................................................................. SC – 3

    EX .....................................................................................................................................................................................................SC – 4

    EXC .................................................................................................................................................................................................. SC – 5

    EUT ..................................................................................................................................................................................................SC – 6

    ETC ..................................................................................................................................................................................................SC – 7

    EY .....................................................................................................................................................................................................SC – 9

    EYC ................................................................................................................................................................................................SC – 10

    EY 3 ................................................................................................................................................................................................SC – 12

    EYC 3 ............................................................................................................................................................................................. SC – 13

    EPC ................................................................................................................................................................................................SC – 15

    ES (Non-current carrying)............................................................................................................................................................... SC – 16

    ESC (Current carrying) ................................................................................................................................................................... SC – 17

    EXP ................................................................................................................................................................................................SC – 18

    EXCP .............................................................................................................................................................................................. SC – 19

    EYBC .............................................................................................................................................................................................. SC – 20

    EPT.................................................................................................................................................................................................SC – 21

    EPT 2.............................................................................................................................................................................................. SC – 22

    EEPC .............................................................................................................................................................................................. SC – 23

    Jaws for AI Sleeve .......................................................................................................................................................................... SC – 24

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 2 SublignTM

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 3SublignTM

    Outline Specifications and Service conditions

    TYPEDIAMETER

    (mm)LENGTH

    (mm)REMARKS

    Stranded All Aluminium Conductors

    16.25 HORNET

    26.46 CENTIPEDE

    38.34 BULL

    Stranded All Aluminium Alloy Conductors

    6.24 ACACIA

    8.31 35

    10.83 PINE

    13.95 OAK

    17.4 ASH

    22.61 SYCAMORE

    24.71 UPAS

    Stranded Aluminium Conductors Steel Reinforced

    7.08 – 10.98 GOPHER TO MINK

    14.16 – 18.13 HARE TO WOLF

    18.87 CHICKADEE

    23.45 BEAR

    23.90 KINGBIRD

    25.97 GOAT

    27.00 TERN

    28.62 ZEBRA

    35.50 DINOSAUR

    35.58 BERSFORD

    Stems

    26.0 125

    38.0 125

    60.0 125

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 4 SublignTM

    EX

    The EX – type Clamp is a bolted cross clamp and they are capable of making connections that are in-line or at an angle of 90° at either end of the clamp. A is designed to bolt onto a solid stem and B is designed to bolt onto stranded conductor.

    EX – Clamps are generally only to be used in non-current carrying applications e.g. through connections on support post insulators, voltage transformers and surge arresters. Each half clamp is fitted with two independent clamping saddles.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    DIAMETER (mm) (IN)

    RATED CURRENT

    MAXIMUM VOLTAGE

    (UM)

    A B [A rms] [KV rms]

    EX – A K1 26 16.3 457 145

    EX – B K2 26 26.5 833 300

    EX – C K3 38 16.3 457 145

    EX – D K4 38 26.5 833 300

    EX – E K5 38 38.3 1300 420

    EX – F K6 38 19.0 530 300

    EX – G K7 35 26.5 833 300

    EX – H K8 35 38.3 900 420

    EX – J K9 26 19.0 530 300

    EX – K K10 26 21.0 630 300

    • All clamps supplied with M10/12 HDG bolts, nuts and washers

    • Recommended Torque: M10: 30 Nm / M12:45Nm

    NOTES:• Bolted-Bolted cross clamps for making

    bolted connections between solid equipment stems and stranded conductor in low or non-current carrying applications.

    • Fasteners M12 GR. 8.8 HDG to ISO 1461. Torque to 45Nm.

    • (C) Cat No. to be cast on substation body casting.

    • All bolted clamps and conductors surfaces to be cleaned with a stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 5SublignTM

    EXC

    These bolted-compression clamps are designed for making connections between a solid terminal stem and a stranded conductor. The bolted end is intended for bolting to a solid stem, whilst the compression end is designed for crimping onto a stranded conductor. The bolted end is fitted with two independent clamping saddles.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    EQUIPMENT TERMINAL

    (A)

    CONDUCTOR DIAMETER (B) (mm)

    ANGLE OF

    (C) OFFSET

    RATED CURRENT

    [IN] (A rms)

    MAXIMUM VOLTAGE

    [UM] (KV rms)

    EXC – A KC1 26 26.5 0° 833 300

    EXC – B KC2 38 26.5 0° 833 300

    EXC – C KC3 38 38.3 0° 1300 420

    EXC – D KC4 38 38.3 45° 1300 420

    EXC – E KC5 38 38.3 90° 1300 420

    EXC – F KC6 38 26.5 45° 833 300

    EXC – G KC7 38 26.5 90° 833 300

    EXC – H KC8 38 18.1 0° 470 245

    EXC – J KC9 35 26.5 0° 833 300

    EXC – K KC10 35 38.3 0° 1100 420

    EXC – L KC11 26 26.5 45° 833 300

    EXC – M KC12 26 18.1 0° 470 245

    EXC – N KC13 40 26.5 0° 833 300

    EXC – P KC14 60 38.3 0° 1300 420

    EXC – Q KC15 60 38.3 45° 1300 420

    EXC – R KC16 60 38.3 90° 1300 420

    * Refer to page SC – 24 for the die size for Alcan Compression Fittings

    • All clamps supplied with M12 HDG, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• To connect a sold stem to a stranded

    conductor by bolting clamp to terminal stem and crimping conductor in compression tube.

    • Fasteners M12 GR 8.8 HDG torque to 45Nm

    • (D) Cat no. to be stamped in the location shown.

    • Compression die and size stamped on tube. 3 crimps required.

    • Tube is pre-greased with conductive grease and sealed with plastic cap.

    • All terminal palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast and Extruded aluminium

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 6 SublignTM

    EUT

    These clamps are of the bolted type clamp suitable for making “Tee” connections off a busbar or line conductor. The “RUN” as well as the “TAP” is fitted with two independent bolted saddles.

    EUT – Type Clamps should only be used in very low or non-current carrying applications.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    DIAMETER (mm)

    RATED CURRENT

    MAXIMUM VOLTAGE

    (IN) (UM) A B [A RMS] [KV RMS]

    EUT – A UT – 1 6 – 11 6 – 11 250 145

    EUT – B UT – 2 12 – 21 12 – 21 500 145

    EUT – C UT – 3 12 – 21 22 – 28 500 145

    EUT – D UT – 4 22 – 28 12 – 21 500 145

    EUT – E UT – 5 22 – 28 22 – 28 600 145

    EUT – F UT – 6 12 – 21 6 – 11 250 145

    • All clamps supplied with M12 Galvanised U-bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• Range taking clamps for making bolted tee

    connections off busbar or line conductor in low or non-current carrying applications.

    • Fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • (C) Cat no. to be cast on substation body component. All bolted clamp and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium

    • Supplied in clear, sealed, heavy duty, uv stabilized plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 7SublignTM

    ETC

    These are bolted “TEE”-compression clamps and are designed to make connections from a stranded conductor “RUN” which is under tension, onto a stranded conductor “TEE” connecting to equipment. The bolted “RUN” section of these clamps are fitted with three independent clamping saddles.

    NOTES:• To connect a stranded conductor “run” under

    tension to a stranded conductor “tap” by bolting palm to run conductor and crimping tap conductor in compression tube.

    • (D) Cat no. to be stamped in the location shown.

    • Material cast and extruded aluminium.

    • Fasteners M12 GR. 8.8 HDG torque to 45Nm

    • Compression die and size stamped on tube. 3 crimps required.

    • Tube is pre-greased with conductive grease and sealed with plastic cap.

    • All bolted joint clamp and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    DIAMETER (mm) (IN)

    RATED CURRENT

    MAXIMUM VOLTAGE (UM)

    A-RUN B-TAP (C) ANGLE [A RMS] [KV RMS]

    ETC – A TC 1 23.5 26.5 0 ° 650 300

    ETC – B TC 2 23.5 38.3 0 ° 650 300

    ETC – C TC 3 26.5 26.5 0 ° 833 300

    ETC – D TC 4 26.5 38.3 0 ° 833 300

    ETC – E TC 5 28.6 26.5 0 ° 833 300

    ETC – F TC 6 28.6 38.3 0 ° 860 300

    ETC – G TC 7 35.6 26.5 0 ° 833 300

    ETC – H TC 8 35.6 38.3 0 ° 1100 420

    ETC – J TC 9 38.3 26.5 0 ° 833 300

    ETC – K TC 10 38.3 38.3 0 ° 1300 420

    ETC – L TC 11 18.1 26.5 0 ° 470 145

    ETC – M TC 12 18.1 18.1 0 ° 470 145

    ETC – N TC 13 26.5 18.1 0 ° 470 145

    ETC – P TC 14 38.3 18.1 0 ° 470 145

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 8 SublignTM

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    DIAMETER (mm) (IN)

    RATED CURRENT

    MAXIMUM VOLTAGE (UM)

    A-RUN B-TAP ANGLE [A RMS] [KV RMS]

    ETC – Q TC 15 38.3 16 0 ° 450 145

    ETC – R TC 16 26.5 16 0 ° 450 145

    ETC – S TC 17 16 16 0 ° 450 145

    ETC – T TC 18 26.5 26.5 45 ° 833 300

    ETC – U TC 19 38.3 26.5 45 ° 833 300

    ETC – V TC 20 38.3 38.3 45 ° 1300 420

    ETC – W TC 21 18.1 16.25 0 ° 470 145

    ETC – X TC 22 26.5 16.25 0 ° 450 145

    ETC – Y TC 23 38.3 16.25 0 ° 450 145

    ETC – Z TC 24 25.97 26.5 0 ° 730 300

    ETC – AA TC 25 25.97 38.3 0 ° 730 300

    ETC – AB TC 26 24.71 26.5 0 ° 718 145

    ETC – AC TC 27 24.71 38.3 0 ° 718 145

    ETC – AD TC 28 22.61 26.5 0° 643 145

    ETC – AE TC 29 22.61 38.3 0 ° 643 145

    * Refer to page SC - 24 for the die size for Alcan Compression Fittings

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    ETC

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 9SublignTM

    EY

    These clamps are of the bolted type clamps and are designed for making a connection onto a single solid terminal stem for a pair of stranded conductors.

    They can be used as a single tap off from a twin conductor bundle.

    They should only be used for non-current carrying purposes e.g. through connections on support post insulators, voltage transformers and surge arresters as applicable.

    “EY” clamps should not be used on end connections. Two clamping saddles shall be provided for each connection.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    CONNECTION TO CONDUCTOR

    STEM DIAMETER

    RATED CURRENT

    [IN]

    MAXIMUM VOLTAGE

    [UM]

    ANGLE DIAMETER (A) (mm) (B) (mm) (A RMS) (KV RMS)

    EY – A Y 1 0° 26.5 38 1300 300

    EY – B Y 2 0° 38.3 38 1300 420

    EY – C Y 3 90° 26.5 38 1300 300

    EY – D Y 4 90° 38.3 38 1300 420

    EY – E Y 5 0° 26.5 26 833 300

    EY – F Y 6 90° 26.5 26 833 300

    EY – G Y 7 90° 38.3 26 833 420

    EY – H Y 8 0° 38.3 26 833 420

    EY – J Y 9 0°/90° 38.3 60 2400 420

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• Bolted-Bolted cross clamps for making a

    bolted connection between a twin stranded conductor bundle and a solid equipment stem can be used for current carrying and non-current carrying applications. Not to be used on end connections.

    • Fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • (C) Cat no. to be stamped in the location shown

    • All bolted clamp and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV Stabilised plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 10 SublignTM

    EYC

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 11SublignTM

    EYC

    These clamps are similar to the bolted “EY” clamps, however on the pair of stranded conductor’s side it has compression connections with 0°, 45°or 90°orientation. Two clamping saddles are provided for the bolted connection.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    EQUIPMENT TERMINAL

    A

    CONDUCTOR DIAMETER (B) (mm)

    ANGLE OF OFF SET (C)

    RATED CURRENT

    [IN] (A rms)

    MAXIMUM VOLTAGE

    [UM] (KV rms)

    EYC – A YC1 38 26.5 0° 1300 300

    EYC – B YC2 38 38.3 0° 1300 400

    EYC – C YC3 38 26.5 45° 1300 300

    EYC – D YC4 38 38.3 45° 1300 420

    EYC – E YC5 38 26.5 90° 1300 300

    EYC – F YC6 38 38.3 90° 1300 420

    EYC – G YC7 60 38.3 0° 2100 420

    EYC – H YC8 60 38.3 45° 2100 420

    EYC – J YC9 60 38.3 90° 2100 420

    EYC – K YC10 26 26.5 0° 833 300

    EYC – L YC11 26 26.5 45° 833 300

    EYC – M YC12 26 26.5 90° 833 300

    EYC – N YC13 9 Bolt Pad to IEC 60518 38.3 0° 2400 420

    EYC – P YC14 9 Bolt Pad to IEC 60518 38.3 45° 2400 420

    EYC – Q YC15 9 Bolt Pad to IEC 60518 38.3 90° 2400 420

    EYC – R YC16 8 Bolt Pad to IEC 60518 38.3 0° 2600 420

    EYC – S YC17 8 Bolt Pad to IEC 60518 38.3 45° 2600 420

    EYC – T YC18 8 Bolt Pad to IEC 60518 38.3 90° 2600 420

    EYC – U YC19 9 Bolt Pad to IEC 60518 26.5 0° 1660 300

    EYC – V YC20 9 Bolt Pad to IEC 60518 26.5 45° 1660 300

    EYC – W YC21 9 Bolt Pad to IEC 60518 26.5 90° 1660 300

    EYC – X YC22 8 Bolt Pad to IEC 60518 26.5 0° 1660 300

    EYC – Y YC23 8 Bolt Pad to IEC 60518 26.5 45° 1660 300

    EYC – Z YC24 8 Bolt Pad to IEC 60518 26.5 90° 1660 300

    EYC – AA YC25 60 26.5 0° 1660 300

    EYC – AB YC26 60 26.5 45° 1660 300

    EYC – AC YC27 60 26.5 90° 1660 300

    * Refer to page SC - 24 for the die size for Alcan Compression Fittings

    • All clamps supplied with M12 HDG, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• To connect a twin stranded conductor bundle to a solid terminal stem by a bolting clamp to stem

    and crimping conductor in compression tube.

    • Recommended fasteners M12 GR. 8.8 torque to 45 Nm.

    • Compression die and size stamped on tube. 3 crimps required.

    • Cat no. to be stamped on product.

    • Tube is pre-greased with conductive grease and sealed with plastic cap.

    • All terminal, palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast and extruded aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • All palms in accordance with IEC 62271-301.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 12 SublignTM

    EY 3

    These clamps are intended for use in conjunction with post insulators to support phase conductor bundles between items of outdoor high voltage apparatus.

    They are of the bolted type designation for making connections between horizontal triple conductors and a single vertical stem. Provided that the clamp is applied correctly with reference to the current rating, this clamp can be used as a single tap off from a triple conductor bundle. They should generally only be used for non-current carrying purposes, e.g. through connections on support post insulators, voltage transformers and surge arresters as applicable.

    NEW TYPE DESIGNATION CONNECTION TO

    STEM DIAMETER

    RATED CURRENT

    MAXIMUM VOLTAGE

    ANGLE DIAMETER (B) (mm)

    (A) (mm)

    [IN] (A RMS)

    [UM] (KV RMS)

    EY 3 – A 90° 38.3 38 2500 420

    EY 3 – B 90° 38.3 60 3150 420

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• Bolted-Bolted cross clamps for making a

    bolted connection between a triple stranded conductor bundle and a solid equipment stem. Can be used for current carrying and non-current carrying applications. Not be used on end connections.

    • Fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Cat no. to be stamped on product.

    • All bolted clamp and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 13SublignTM

    EYC 3

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 14 SublignTM

    EYC 3

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    EQUIPMENT TERMINAL

    A

    CONDUCTOR DIAMETER (B) (mm)

    ANGLE OF OFF SET (C)

    RATED CURRENT

    [IN] (A RMS)

    MAXIMUM VOLTAGE

    [UM] (KVRMS)

    EYC 3 – A 3YC1 60 38.3 0° 2100 420

    EYC 3 – B 3YC2 9 Bolt Pad 38.3 0° 2400 420

    EYC 3 – C 3YC3 60 38.3 45° 2100 420

    EYC 3 – D 3YC4 9 Bolt Pad 38.3 45° 2400 420

    EYC 3 – E 3YC5 60 38.3 90° 2100 420

    EYC 3 – F 3YC6 9 Bolt Pad 38.3 90° 2400 420

    EYC 3 – G 3YC7 8 Bolt Pad 38.3 0° 2600 420

    EYC 3 – H 3YC8 8 Bolt Pad 38.3 45° 2600 420

    EYC 3 – J 3YC9 8 Bolt Pad 38.3 90° 2600 420

    * Refer to page SC – 24 for the die size for Alcan Compression Fittings

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    These clamps are similar to the bolted “EY” clamps, however on the pair of stranded conductor’s side it has compression connections with 0°, 45°or 90°orientation. Two clamping saddles are provided for the bolted connection.

    These clamps are similar to the twin-conductor “EYC” clamp, except that it has a higher current rating based on, them having three conductors per stem/pad.

    NOTES:• To connect a triple stranded conductor bundle to a solid terminal stem by bolting clamp to stem and

    crimping conductor in compression tube.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Compression die and size stamped on tube. 3 crimps required.

    • Cat no. to be stamped on the product.

    • Tube is pregreased with conductive grease and sealed with plastic cap.

    • All terminal palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast and Extruded Aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • All palms in accordance with IEC 62271-301.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 15SublignTM

    EPC

    Palm-compression clamps are designed for making connections from flat terminal pads onto single stranded conductors, the palm being bolted directly onto the terminal pad and the conductor end connected with a compression fitting.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    CONDUCTOR DIAMETER (C) (mm)

    PAD/STEM DIMENSIONS

    (A) (mm)ANGLE OF

    OFF SET (B)

    RATED CURRENT

    [IN] (A RMS)

    MAXIMUM VOLTAGE

    [UM] (KVRMS)

    EPC – A SPC 1 26.5 4 X 14 DIA HOLES50 X 50 CENTERS

    0° 833 245

    EPC – B SPC 2 26.5 45° 833 245

    EPC – C SPC 3 26.5 90° 833 245

    EPC – D SPC 4 38.34 X 14 DIA HOLES50 X 50 CENTERS

    0° 1100 300

    EPC – E SPC 5 38.3 45° 1100 300

    EPC – F SPC 6 38.3 90° 1100 300

    EPC – G SPC 7 26.5 4 X 14 DIA HOLES80 X 80 CENTERS

    0° 833 245

    EPC – H SPC 8 26.5 45° 833 245

    EPC – J SPC 9 26.5 90° 833 245

    EPC – K SPC 10 38.34 X 14 DIA HOLES80 X 80 CENTERS

    0° 1300 300

    EPC – L SPC 11 38.3 45° 1300 300

    EPC – M SPC 12 38.3 90° 1300 300

    EPC – N SPC 13 26.5 UNDRILLED 0° 833 245

    EPC – P SPC 14 38.3 UNDRILLED 0° 1300 300

    * Refer to page SC – 24 for the die size for Alcan Compression Fittings

    NOTES:• To connect a flat terminal to a stranded conductor by bolting palm to terminal and crimping

    conductor in compression tube.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Compression die and size stamped on tube. 3 crimps required.

    • Tube is pre-greased with conductive grease and sealed with plastic cap.

    • All terminal, palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast and extruded aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as shown.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 16 SublignTM

    ES (Non-current carrying)

    Spacers are designed to keep standard conductors at specified distances apart and are designed to withstand the forces that occur under short circuit conditions.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    CONDUCTOR DIAMETER (A) (mm)

    SPACING (B) (mm)

    NUMBER OF CONDUCTORS

    3 - SECONDS RATED SHORT

    CIRCUIT CURRENT

    [IF] [KV RMS]

    MAXIMUM VOLTAGE

    [UM] (KV RMS)

    ES – A S1 26.5 150 2 31.5 300

    ES – B S2 38.3 150 2 50 420

    ES – C S3 26.5 330 2 31.5 300

    ES – D S4 38.3 330 2 50 420

    ES – E S5 38.3 165 3 50 420

    • Fittings supplied with HDG M12 bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• Non-current carrying spacers to keep

    standard conductors at specifies distances apart. Able to withstand forces that occur under short circuit condition.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Groove and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as shown .

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 17SublignTM

    ESC (Current carrying)

    These spacers are designed to equalize the phase conductor bundle drop off points from the busbars where phase dropper conductor bundles of fewer conductors per bundle are used. They keep standard conductors at specified distances apart and are designed to withstand the forces that occur under short circuit conditions.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    CONDUCTOR

    DIAMETER (A) (mm)

    SPACING (B)

    (mm)NUMBER OF

    CONDUCTORS

    3 - SECONDS RATED SHORT CIRCUIT

    CURRENT [IF] [KV RMS]

    RATED CURRENT

    [IN] (A RMS)

    MAXIMUM VOLTAGE [UM] (KV

    RMS)

    ESC – A S10 26.5 150 2 31.5 833 300

    ESC – B S11 38.3 150 2 50 1300 420

    ESC – C S12 26.5 330 2 31.5 833 300

    ESC – D S13 38.3 330 2 50 1300 420

    ESC – E S14 38.3 165 3 50 1300 420

    • Fittings supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• Current carrying spacers to keep standard

    conductors at specifies distances apart. Able to withstand forces that occur under short circuit condition.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Groove and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as shown.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 18 SublignTM

    EXP

    These bolted cross-pad clamps are intended for making connections between stranded conductors/stems and pads. These clamps should not be used as adaptors.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    STEM DIAMETER (A) (mm)

    PALM SIZE (C X D) (mm)

    MAX RATING (A)

    MAXIMUM VOLTAGE

    [UM] (KV RMS)

    EXP – A STP 26 26 100 X 100 833 245

    EXP – B STP 38 38 100 X 100 1300 300

    • All clamps supplied with M12 HDG, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• To connect a flat terminal to a stranded

    conductor by bolting palm to terminal and bolting conductor.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • All terminal, palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as show .

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 19SublignTM

    EXCP

    These pedestal-mounted bolted clamps are intended for making connections between stranded conductors and post insulators.

    NEW TYPE DESIGNATION

    RUN SIZE (mm) A

    (B) PCD (mm)

    RATED CURRENT [IN]

    (A RMS)

    MAXIMUM VOLTAGE [UM]

    (KV RMS)

    EXCP – A 26.5 76 900 145

    EXCP – B 26.5 127 900 145

    EXCP – C 38.3 76 1300 145

    EXCP – D 38.3 127 1300 145

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• Non-current carrying for supporting stranded

    conductor on post insulators.

    • Fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Cat. no. to be stamped as shown.

    • All bolted clamp and conductor surfaces with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 20 SublignTM

    EYBC

    These clamps are designed to equalize the phase conductor bundle drop off points from the busbars where phase dropper conductor bundles of fewer conductors per bundle are used. They keep standard conductors at specified distances apart and are designed to withstand the forces that occur under short circuit conditions.

    NEW TYPE DESIGNATION

    OLD TYPE DESIGNATION

    CONDUCTOR SIZE

    (A) (mm)

    CENTRE SPACING (C) (mm)

    CONDUCTOR SIZE

    (B) (mm)

    RATED CURRENT

    [IN] (A RMS)

    MAXIMUM VOLTAGE [UM] (KV

    RMS)

    EYBC – A YBC26/26/15 2 X 26.5 150 26.5 833 300

    EYBC – B YBC26/28/33 2 X 26.5 330 38.3 1300 420

    EYBC – C YBC38/26/15 2 X 38.3 150 26.5 833 300

    EYBC – D YBC38/38/15 2 X 38.3 150 38.3 1300 420

    EYBC – E YBC38/38/33 2 X 38.3 330 38.3 1300 420

    * Refer to page SC – 24 for the die size for Alcan Compression Fittings

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• To connect stranded conductors by crimping

    conductor in compression tube and by bolting to clamp.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Compression die and size stamped on tube. 3 crimps required.

    • Tube is pre-greased with conductive grease and sealed with plastic cap.

    • Groove and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast and extruded aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as shown.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 21SublignTM

    EPT

    These bolted-type clamps shall be used mainly for connecting single stranded conductors to earth switches with 4-hole pad terminals.

    NEW TYPE DESIGNATION

    CONDUCTOR DIAMETER (A) (mm)

    EQUIPMENT TERMINAL

    RATED CURRENT [IN] (A RMS)

    MAXIMUM VOLTAGE [UM]

    (KV RMS)

    EPT – A 26.5 4 Bolt Pad 900 145

    EPT – B 38.3 4 Bolt Pad 1350 145

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    NOTES:• To connect a flat terminal to a stranded

    conductor by bolting palm to terminal and crimping conductor in compression tube.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • All terminal, palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as shown.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 22 SublignTM

    NOTES:• To connect a flat terminal to a stranded

    conductor by bolting palm to terminal and crimping conductor in compression tube.

    • Recommended fasteners M12 GR. 8.8 HDG torque to 45Nm.

    • Compression die and size stamped on tube. All terminal, palm and conductor surfaces to be cleaned with stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

    • Cat. no. to be stamped as shown.

    EPT 2

    These bolted-type clamps shall be used mainly for connecting twin stranded conductors to earth switches with 8-hole pad terminals.

    NEW TYPE DESIGNATION

    CONDUCTOR DIAMETER

    (mm) (A)

    CONDUCTOR SPACING

    (mm)EQUIPMENT TERMINAL

    RATED CURRENT

    [IN] (A RMS)

    MAXIMUM VOLTAGE

    [UM] (KV RMS)

    EPT2 – A 2 x 26.5 150 8 Bolt Pad 1700 145

    EPT2 – B 2 x 38.3 150 8 Bolt Pad 2700 420

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 23SublignTM

    EEPC

    NEW TYPE DESIGNATION

    CONDUCTOR DIAMETER

    (mm) (A)

    CONDUCTOR DIAMETER

    (mm) (D)

    RATED CURRENT

    [IN] (A RMS)

    MAXIMUM VOLTAGE

    [UM] (KV RMS)

    EEPC – A 26.5 26 900 300

    EEPC – B 38.3 26 900 420

    EEPC – C 16.3 26 900 145

    • All clamps supplied with M12 HDG bolts, nuts and washers

    • Recommended Torque: 45 Nm

    EEPC clamps are used for connecting portable earthing to stranded conductors

    NOTES:• Bolted earthing peg clamps for making a

    bolted connection between single stranded conductor and earthing peg

    • Fasteners M12 GR. 8.8 HDG. Torque to 45Nm.

    • Cat No. should be stamped in location shown.

    • All bolted clamps and conductors surfaces to be cleaned with a stainless steel wire brush and a suitable conductive grease applied before use.

    • Material: Cast aluminium.

    • Supplied in clear, sealed, heavy duty, UV stabilized plastic bag.

  • tel +27 (0)33 397 5800 ı [email protected] ı www.preformedsa.co.za © 2017 Preformed Line Products South Africa

    Disclaimer: PLP reserves the right to make changes to the data presented in this brochure when required. Every effort has been made to ensure the accuracy of the information in this brochure. PLP disclaims responsibility for any liabilities, claims, damages, and costs arising from the incorrect use of this information.

    SC – 24 SublignTM

    Jaws for AI Sleeve

    DRAWING NO 1 DIMENSIONS (mm)

    CONDUCTOR DIAMETER

    ALKAN NO’S CAT NO MARKINGS S L R

    MASS (kg)

    16,0-16,3 K-32 60860-26 30-26/30 A 26 47 3 3,70

    18,1 A-8 60860-28 30-28/32 A 28 47 3 3,75

    26,5 A-10 60860-36 30-36/42,5 A 36 42 5 3,55

    38,3 A13 60860-49 30-49/58 A 49 40 5 3,35

    DRAWING NO 2 DIMENSIONS (mm)

    CONDUCTOR DIAMETER

    ALKAN NO’S CAT NO MARKINGS S L R

    MASS (kg)

    16,0-16,3 K-32 60120-26 100-26/30 A 26 70 3 4,50

    18,1 A-8 60120-28 100-28/32 A 28 70 3 4,40

    26,5 A-10 60120-36 100-36/42,5 A 36 70 5 4,10

    Material: Toughened alloy steel

    Application: These jaws are mating parts with the GPH-300 (1) or GPH-1000 (2) head

    Notes: One set consists of two jaws marked with the same catalogue number.

    Outline Specifications and Service conditionsEXEXCEUTETCEYEYCEY 3EYC 3EPCES (Non current carrying)ESC(Current carrying)EXPEXCPEYBCEPTEPT 2EEPCJaws for AI Sleevesubstation clampsIndex

    Button 3: Page 1: Page 31: Page 52: Page 73: Page 94: Page 115: Page 136: Page 157: Page 178: Page 199: Page 2110: Page 2311:

    Button 5: Page 1: Page 31: Page 52: Page 73: Page 94: Page 115: Page 136: Page 157: Page 178: Page 199: Page 2110: Page 2311:

    Button 1: Page 2: Page 41: Page 62: Page 83: Page 104: Page 125: Page 146: Page 167: Page 188: Page 209: Page 2210: Page 2411:

    Button 6: Page 2: Page 41: Page 62: Page 83: Page 104: Page 125: Page 146: Page 167: Page 188: Page 209: Page 2210: Page 2411: