structural steeljhwilliamsinc.com/wp-content/uploads/2021/04/ep-plans.pdf · 2021. 4. 23. ·...
TRANSCRIPT
X
X
X
Set Issue:
ISSUED FOR BID
STRUCTURAL STEEL
1. ALL STRUCTURAL WORK SHALL CONFORM TO AISC'S "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, 360-16.
2. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOWING DESIGNATIONS:
CHANNELS & PLATES ASTM A36
THREADED RODS ASTM A36
3. WELDING, WELDING ELECTRODES, AND FLUXES SHALL CONFORM TO AWS D1.1-11 "STRUCTURAL WELDING CODE - STEEL".
ELECTRODES SHALL HAVE A MINIMUM TENSILE STRENGTH OF 70 KSI.
4. ALL STEEL SHALL RECEIVE TWO COATS OF FABRICATION STANDARD RUST-INHIBITIVE PRIMER.
CONCRETE MASONRY
1. CONCRETE MASONRY WORK SHALL CONFORM TO "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES", TMS 402-16, AND
"SPECIFICATIONS FOR MASONRY STRUCTURES", TMS 602-16.
2. INJECT OPEN CORES OF WALL WITH GROUT.
3. GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI @ 28 DAYS.
1. Jurisdiction: Edgewater Park Twp.., State of New Jersey
2. Applicable Codes:
A. International Building Code/2018 New Jersey Edition
B. ASHRAE 90.1-2016
C. International Mechanical Code/2018
D. National Electric Code/2017
E. National Standard Plumbing Code/2018
F. N.J.A.C. 5:23-6 Rehabilitation Sub Code
G. N.J.A.C. 5:23-7 Barrier Free Subcode and ICC-ANSI A117.1-2009
3. Use Group/Occupancy: B-Business
4. Construction Classification: Type IIB, Non-Combustible, 1 Story
1. ALL WORK SHALL CONFORM TO THE INTERNATIONAL BUILDING CODE-2018 NEW JERSEY EDITION AND ALL OTHER APPLICABLE CODES, ORDINANCES, ETC. FOR NEW
JERSEY STATE AND THE LOCAL AUTHORITY HAVING JURISDICTION.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR VISITING THE SITE AND FAMILIARIZING HIMSELF WITH THE EXISTING CONDITIONS AND SCOPE OF THE WORK PRIOR TO
SUBMITTING BIDS AND COMMENCING WORK.
3. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL SAFE WORKING CONDITIONS AND SHALL OBSERVE ALL SAFETY REQUIREMENTS ESTABLISHED BY JURISDICTIONAL
AGENCIES AND THE OWNER. WHERE CONFLICTS EXIST, THE MORE STRINGENT REQUIREMENT SHALL APPLY. CARE SHALL BE EXERCISED TO AVOID ENDANGERING
PERSONNEL OR STRUCTURES.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONSTRUCTION METHODS, PROCEDURES AND JOB SITE CONDITIONS INCLUDING SAFETY. CONSTRUCTION SHALL BE
PERFORMED IN SUCH A MANNER TO PROTECT WORKMEN, OCCUPANTS AND THE PUBLIC FROM INJURY AND ADJOINING PROPERTY SHALL BE PROTECTED FROM DAMAGE
BY USE OF SCAFFOLDING, UNDERPINNING OR OTHER APPROVED METHOD. THE CONTRACTOR SHALL REPAIR ANY AND ALL DAMAGE CAUSED DURING OR RESULTING
FROM HIS OPERATIONS IN KIND TO THE SATISFACTION OF THE OWNER AT NO ADDITIONAL COST TO THE OWNER.
5. THE CONTRACTOR SHALL MAINTAIN THE JOB SITE IN A CLEAN, DEBRIS FREE CONDITION. THE DUST RESULTING FROM REMOVALS SHALL BE CONTROLLED SO AS TO
PREVENT ITS SPREAD TO OCCUPIED PORTIONS OF THE BUILDING AND TO AVOID CREATION OF A NUISANCE IN THE SURROUNDING AREA.
6. CONTRACTOR SHALL SECURE ALL REQUIRED PERMITS, APPROVALS, ETC. PRIOR TO COMMENCING WORK AND SHALL SECURE CERTIFICATE OF OCCUPANCY UPON
COMPLETION OF WORK.
7. CONTRACTOR SHALL BE RESPONSIBLE TO DISPOSE OF ALL DEMOLISHED MATERIAL OFF SITE IN AN APPROVED MANNER. THE OWNER SHALL BE CONSULTED PRIOR TO
DISPOSAL OF ANY SALVAGED OR EXCESS MATERIALS AT THE COMPLETION OF THE PROJECT. UPON COMPLETION OF WORK, ALL EXCESS MATERIAL, DEBRIS, ETC. SHALL
BE REMOVED AND THE WORK AREA SHALL BE LEFT CLEAN TO THE OWNER'S SATISFACTION.
8. ALL WORK SHALL BE SCHEDULED IN COMPLIANCE WITH THE OWNER'S REQUIREMENTS FOR THE USE OF THE EXISTING FACILITY.
9. CONTRACTOR SHALL FURNISH ALL EQUIPMENT THAT MAY BE REQUIRED TO PERFORM THE WORK INDICATED IN A SAFE AND ORDERLY MANNER.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE RELOCATION AND TEMPORARY SUPPORT OF ANY UTILITIES ENCOUNTERED DURING THE COURSE OF HIS WORK AND
TO ENSURE THE OWNER'S FACILITY TO BE OPERATIONAL.
11. THE CONTRACTOR SHALL REVIEW DRAWINGS AND FIELD VERIFY ALL DIMENSIONS, CONDITIONS AND ELEVATIONS PRIOR TO COMMENCING WORK. THE CONTRACTOR
SHALL REPORT ANY DISCREPANCIES AND ADDRESS ALL QUESTIONS TO ARCHITECT PRIOR TO COMMENCING WORK.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CUTTING, PATCHING, FILLING AND CLEANING UPON COMPLETION OF WORK.
13. THE CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. ALL WRITTEN OR DIMENSIONED INFORMATION TAKES PRECEDENCE OVER THE DRAWING.
14. THE CONTRACTOR SHALL SUBMIT, WHERE REQUIRED, SHOP DRAWINGS TO THE ARCHITECT FOR APPROVAL PRIOR TO THE START OF FABRICATION OF THOSE ITEMS.
REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
15. THE CONTRACTOR SHALL PROVIDE THE OWNER AND ARCHITECT WITH CERTIFICATES OF INSURANCE PRIOR TO STARTING THE WORK.
16. ALL MANUFACTURER'S MATERIALS, COMPONENTS, FASTENERS, ASSEMBLIES, ETC. SHALL BE HANDLED AND INSTALLED IN ACCORDANCE TO WITH MANUFACTURERS
INSTRUCTIONS AND RECOMMENDATIONS. WHERE BRAND NAMES AND MANUFACTURED PRODUCTS ARE CALLED FOR, APPROVED EQUALS WHICH MEET APPLICABLE
STANDARDS AND SPECIFICATIONS MAY BE SUBSTITUTED WITH WRITTEN PERMISSION OF THE ARCHITECT AND THE OWNER. WHENEVER BRAND NAMES OR SPECIFIC
PRODUCT SYSTEMS ARE INDICATED IT SHALL BE CLEARLY UNDERSTOOD THAT SUCH IDENTIFICATION IS FOR THE PURPOSE OF ILLUSTRATING THE TYPE OF PRODUCT AND
DEGREE OF QUALITY DESIRED. SUCH IDENTIFICATION IN NO WAY PRECLUDES THE CONTRACTOR FROM USING PRODUCTS OF OTHER MANUFACTURERS WHICH CAN BE
SHOWN IN ADVANCE TO BE OF LIKE AND OF EQUAL QUALITY.
17. ALL CHANGES SHALL BE REQUESTED IN WRITING AND MAY ONLY BE APPROVED IN WRITING BY THE ARCHITECT AND THE OWNER PRIOR TO ANY CHANGES BEING MADE.
18. THE ARCHITECT HAS THE RIGHT TO REJECT ANY PORTION OF WORK THAT IS POORLY INSTALLED, DOES NOT MEET INDUSTRY STANDARD, UNAUTHORIZED, OR WORK DONE
CONTRARY TO THE THE INTENT OF THE CONTRACT DOCUMENTS. SUCH WORK SHALL BE REPLACED, REPAIRED OR REMOVED AT THE CONTRACTOR'S EXPENSE.
19. THE CONTRACTOR SHALL GUARANTEE ALL THEIR WORK AND THE WORK OF HIS SUBCONTRACTORS FOR A PERIOD OF TWO YEARS AFTER RECEIVING FINAL ACCEPTANCE
AND DO ALL REPAIR WORK AND REPLACEMENT AS NECESSARY DURING THAT PERIOD AT THE CONTRACTOR'S EXPENSE.
20. IN NO EVENT SHALL STRUCTURAL MEMBERS BE CUT OR DRILLED WITHOUT THE WRITTEN APPROVAL OF A LICENSED STRUCTURAL ENGINEER.
21. ALTHOUGH NOT EXPECTED, CONTRACTOR SHALL STOP WORK AND IMMEDIATELY NOTIFY THE OWNER & ARCHITECT SHOULD THEY SUSPECT OR ENCOUNTER ANY
ASBESTOS RELATED MATERIAL.
$
$
$
3
$
3
MAIN OFFICE
01
TAX ASSESSOR
01A
CONFERENCE
02
TOILET
01B
CLOS.
CLOS.
CORRIDOR
C1
WOMENS
--
4'-0"10'-0"
1'-4"2'-4" 3'-4" 1'-8" 1'-4"
1 2 3 4
4'-6"
5
6
7
TYP.
OF (4)
8
9
10 11
12
13
14
AREA NOT IN
SCOPE OF WORK
4
$
MAIN OFFICE
01
TAX ASSESSOR
01A
CONFERENCE
02
TOILET
01B
CORRIDOR
C1
WOMENS
--
3A1.03
D01A
D01B
$
1'-0"
8'-0"1'-0"
±2"
1'-5"
6'-8"
2'-5" ℄ ℄
AREA NOT IN
SCOPE OF WORK
B01
D02
8"
4" M
AX
TYPICAL STUD PARTITION: 5/8" STANDARD
GWB OVER 3-5/8", 20 GA. MTL STUD AT 16" OC
TO MATCH EXISTING ADJACENT WALL
THICKNESS (VIF); PROVIDE MOISTURE
RESISTANT GWB AT TOILET ROOM
5/8" ABUSE RESISTANT, TYPE 'X'
GWB OVER 1-1/2" 20 GA. MTL
FURRING CHANNELS AT 16"OC
HORIZONTAL (TYP BOTH SIDES
WHERE INDICATED)
5/8" ABUSE RESISTANT, TYPE 'X'
GWB OVER (2) 3-5/8" 20 GA. MTL
STUDS AT 16"OC HORIZONTAL
(TYP WHERE INDICATED)
NEW LINTEL
ABOVE - SEE
DETAILS
RELOCATED
WALL-PACK
SIGNAGE LOCATIONS:
· SINGLE LEAF DOORS - LATCH SIDE
· DOUBLE LEAF DOORS - TO RIGHT SIDE OF
RIGHT LEAF
· WHERE NO WALL SPACE IS AVAILABLE -
NEAREST ADJACENT WALL
· THE BASELINE OF THE LOWEST BRAILLE
CHARACTER ON SIGN SHOULD BE MIN. 48"
AFF.
5'-0" M
AX
. T
O T
HE
TO
P O
F T
HE
S
IG
NA
GE
DOOR & FRAME 'F1'
18"
MIN.
HEIGHT & LOCATION OF SIGNAGE
(ICC/ANSI A117.1-2009)
CENTER LINE
OF SIGN
SIGNAGE NOTES:
1. ALL SIGNAGE TO COMPLY WITH ICC A117.1-2009, CHAPTER 7
REQUIREMENTS FOR SIZE, HEIGHT, CONTRAST, FINISH, & RAISED
CHARACTER REQUIREMENTS.
2. ROOM NAME AND NUMBERS ARE SAMPLES ONLY. OBTAIN FINAL
ROOM NAMES AND NUMBERS FROM OWNER PRIOR TO FABRICATION.
3. PROVIDE BLANK BACK PANEL TO MATCH SIGN FOR SIGNAGE
INSTALLED ON GLASS
8"
6"
TEXT FONT: HELVETICA 3/4"
BRAILLE: 1/4"
CORNERS: 3/8" RADIUS
SIGN TYPE 01
"ROOM NAME "
"NUMBER"
"BRAILLE"
8"
6"
TEXT FONT: HELVETICA 3/4"
BRAILLE: 1/4"
CORNERS: 3/8" RADIUS
SIGN TYPE 02 (UNISEX BATHROOM)
KEY PLAN
1/32" = 1'-0"
Demolition Plan
1/4" = 1'-0"
1
#
SYMBOL INDICATESDEMO KEY NOTEDemolition Key Notes
1. REMOVE EXISTING DOOR & FRAME IN ITS ENTIRETY KEEPING EXG PRE-CAST LINTEL ABOVE IN TACT; FOLLOWING THE
INSTALLATION OF THE STEEL LINTEL: REMOVE PORTION OF EXISTING 8” CMU LOAD BEARING WALL, INCLUDING
BORROWED LITES, AND 2” FURRING & PANEL AT CORRIDOR SIDE AS INDICATED. DEMO EXISTING LIGHT SWITCH &
ELECTRICAL RECEPTACLE AND TAKE BACK TO NEAREST JUNCTION BOX - SEE NEW WORK PLAN FOR NEW RECEPTACLE
LOCATION; SEE DETAIL THIS SHEET FRO STEEL LINTEL INSTALLATION.
2. REMOVE EXISTING DOOR ACCESS CONTROL FOB ACTUATOR & ASSOCIATED WIRING IN ITS ENTIRETY. TERMINATE BACK
TO NEAREST JUNCTION BOX & MAINTAIN FUNCTIONALITY TO ADJACENT DOOR ACCESS CONTROL AT ADJACENT DOOR.
3. REMOVE & RELOCATE EXISTING SURFACE, WALL MOUNTED EMERGENCY WALL PACK. RELOCATE TO LOCATION
INDICATED ON NEW WORK PLAN - CONCEAL WIRING.
4. REMOVE EXISTING DOOR LEAF AND ASSOCIATED HARDWARE. EXISTING HM FRAME TO REMAIN - PREP FRAME TO
ACCOMMODATE NEW OWNER PROVIDED DOOR & HARDWARE. SEE DOOR SCHEDULE.
5. REMOVE DOOR & FRAME IN THEIR ENTIRETY. PREP OPENING TO RECEIVE NEW METAL STUD WALL INFILL.
6. REMOVE EXISTING MTL STUD FRAMED WALL IN ITS ENTIRETY. PATCH OPENING, FLOORING, AND CEILING TO
ACCOMMODATE NEW WORK.
7. REMOVE & RELOCATE EXISTING TELEPHONE & DATA BANK IN ITS ENTIRETY. COORDINATE NEW LOCATION WITH OWNER.
8. REMOVE EXISTING PLUMBING FIXTURES IN THEIR ENTIRETY; MODIFY & RELOCATE PLUMBING ROUGH INS FOR EACH
FIXTURE TO ACCOMMODATE NEW LAYOUT - SEE NEW WORK PLAN.
9. REMOVE & RELOCATE EXISTING TOILET ROOM ACCESSORIES (TOILET PAPER, SOAP, & PAPER TOWEL DISPENSERS) TO
NEW LOCATION INDICATED ON NEW WORK PLAN.
10. REMOVE EXISTING 3 WAY SWITCHES & WIRING BACK TO NEAREST JUNCTION BOX. MODIFY CIRCUITRY TO PROVIDE (1)
SINGLE POLE SWITCH TO CONTROL NEW OWNER PROVIDED WALL MOUNTED LIGHTING FIXTURE.
11. EXISTING BASE BOARD RADIATOR HEAT TO REMAIN.
12. REMOVE EXISTING VCT FLOORING & BASE IN ITS ENTIRETY. PREP EXISTING CONCRETE FLOOR SLAB TO ACCOMMODATE
NEW FINISH.
13. MODIFY EXISTING SUSPENDED ACOUSTIC CEILING TILE SYSTEM & GRID IN ITS ENTIRETY WITHIN MAIN OFFICE & TOILET
ROOM- EXTEND GRID & TILE TO ACCOMMODATE NEW WORK.
14. REMOVE & RELOCATE EXISTING FIRE ALARM STROBE TO LOCATION INDICATED ON NEW WORK PLAN
Set Issue:
ISSUED FOR BID
New Work Plan
1/4" = 1'-0"
2
MAIN ENTRANCE
SECONDARY
ENTRANCE
AREA OF WORK
FINISH SCHEDULE
ROOM # ROOM NAME FLOORS BASE WALLS ACCENT WALL CEILING CEILING HEIGHT REMARKS
01 MAIN OFFICE CPT-E RB-E, RB-1 GWB-P; ETR -- ACT-E, ACT-1 8'-0" ONLY NEW CONSTRUCTION TORECEIVE PAINT & FINISHES
01A TAX ASSESSOR CPT-E RB-E ETR -- ACT-E 8'-0" --
01B TOILET VCT-1 RB-1 GWB-P -- ACT-1 8'-0" --
02 CONFERENCE CPT-E RB-E ETR -- ACT-E ETR --
'E' = EXISTING; ETR = EXISTING TO REMAIN; CPT = CARPET; GWB = GYPSUM WALL BOARD; ACT = ACOUSTIC CEILING TILE; RB = RUBBER BASE
ACT-1: SUSPENDED ACOUSTIC CEILING TILE SYSTEM BY ARMSTRONG OR APPROVED EQ. TO MATCH EXISTING ADJACENT IN ALL RESPECTS
RB-1: 4" STANDARD COVE RUBBER WALL BASE, ROPPE OR APPROVED EQUAL; COLOR SELECTED BY OWNER.
GWB-P: 5/8" GYPSUM WALL BOARD, PAINTED - COLOR SELECTED BY OWNER
VCT-1: VINYL COMPOSITION TILE, EXCELON BY ARMSTRONG, OWNER TO SELECT STANDARD COLOR
DOOR / OPENING SCHEDULE
DOOR # DOOR TYPE MATERIAL # OF LEAVES HEIGHT WIDTH FRAME TYPE FRAME MAT'L HEAD JAMB SILL GLAZING FIRE RATING HARDWARE SET NOTES
D01A G1A WOOD 1 6'-11 1/2" 3'-0" EXG-F1 EXG-HM -- -- -- BRIG-1 -- 1EXG FRAME TO REMAIN; SIGNAGE TYPE 01
D01B F WOOD 1 7'-0" 3'-0" F1 HM -- -- -- N/A -- 2
SIGNAGE TYPE 02; PROVIDE CARPET TO
VCT REDUCER AT SILL; NEW WELDED
FRAME
D02 G1B WOOD 1 6'-11 1/2" 3'-0" EXG-F1 EXG-HM -- -- -- BRIG-1 -- 1EXG FRAME TO REMAIN; SIGNAGE TYPE 01
B01 N/A N/A N/A 4'-0" 8'-0" -- ALUM -- -- -- BRIG-1 -- N/A
SEE SECTION & OWNER PROVIDED SHOP
DRAWINGS
DOOR HARDWARE SETS (PROCURED BY OWNER, INSTALLED BY CONTRACTOR)1. LOCKSET: SIMPLEX 1000; CLOSER: LSDA DC914BC W/ DROP PLATE; HINGE: SELECT SL1183HD2. PROVIDE ADA-COMPLIANT, BORED CYLINDER, COMMERCIAL GRADE MEDIUM DUTY BATHROOM
LOCKSET BY SARGENT OR APP'D EQ.; COORDINATE HARDWARE WITH OWNER PROVIDED DOOR
PRIOR TO PROCUREMENT.
SIGNAGE TYPES & DETAILS
1-1/2" = 1'-0"
6
DOOR / OPENING SCHEDULE NOTES
1. DOORS, HARDWARE, & TRANSACTION WINDOW SYSTEM SHALL BE PROCURED BY OWNER & INSTALLED BY
CONTRACTOR; OWNER TO PROVIDE APPROVED SHOP DRAWINGS TO CONTRACTOR UPON AWARD - THESE
DOCUMENTS CONVEY INTENT ONLY.
2. EXG HM FRAMES TO BE PAINTED.
3. BRIG-1 = BULLET RESISTANT IMPACT GLAZING.
4. DOOR TYPE G1A = OWNER PROCURED SOLID WD DOOR W/ (1) GLAZING LITE, INTEGRAL COUNTER, AND TRANSACTION
TRAY; DOOR TYPE G1B = OWNER PROCURED SOLID WD DOOR W/ (1) GLAZING LITE.
(2)MC12x10.6
1'-4"
2
A1.02
B/STEEL
EL +7'-0"
B/DECK
+10'-4"
2'-0
"1
'-4
"
(2)5/8"Ø A307
THREADED RODS
w/ NUTS & WASHERS
(EA END)
2'-0
"1
'-4
"
GROUT EXTG WALL
SOLID
1/2"Ø ADHESIVE ANCHORS
@ 16" o/c
GROUT EXTG WALL
SOLID
A.F.F.
A.F.F.
1'-4"
1'-0"
NEW OPENING AT EXISTING
LOAD BEARING WALL
1'-0" 10'-0" 1'-0"
CMU LOAD BEARING WALL
RECOMMENDED INSTALLATION PROCEDURE:
1. INJECTION GROUT TWO SECTIONS OF WALL 1'-4" x
3'-4" (MIN) SOLID AS SHOWN ON WALL ELEVATION.
2. SAW CUT BED JOINT IN FACE SHELL OF WALL ON ONE
SIDE OF WALL.
3. INSTALL MC12 WITH 1/4" BOTTOM ƒ IN BED OF
NON-SHRINK GROUT.
4. INSTALL 1/2"Ø ADHESIVE ANCHORS AS SHOWN.
5. REPEAT STEPS 3 & 4 FOR OPPOSITE FACE OF WALL.
6. INSTALL TWO 5/8"Ø THREADED RODS AS SHOWN @
EA END OF LINTEL.
7. REMOVE MASONRY WALL BELOW LINTEL
6"
(2)MC12x10.6
LINTEL
ƒ 3"x1/4"
1/2"Ø HILTI HIT-HY 270
ADHESIVE ANCHORS w/
2" EMBEDMENT @ 16" o/c
(EA SIDE)
EXTG 8" CMU
EXTG JOISTS
WALL TO BE REMOVED
3/16" 2 @ 6"
2"2"
2'-0"
4"
MAX
7
3
4
"
2
1
8
"
2'-10" M
AX
4'-0"
1'-0" V
IF
6"
4
1
4
"
1
1 2
"
WALL BEYOND: 5/8" ABUSE
RESISTANT TYPE 'X' GWB OVER
1-1/2" MTL HAT CHANNELS AT 16"
OC (TYP BOTH SIDES)
5/8" PAINTED ABUSE
RESISTANT, TYPE 'X' GWB
OVER 6" 20GA MTL STUD AT
16" OC
5/8" ABOUSE RESISTANT,
TYPE 'X', PAINTED GWB OVER
OWNER PROVIDED 1/2"
KEVLAR 4X8 PANEL
OWNER PROCURED,
CONTRACTOR INSTALLED
BALLISTIC RATED
TRANSACTION WINDOW
SYSTEM, RECESSED TRAY, AND
PLAM COUNTER
GWB OVER STL LINTEL -
SEE DETAIL THIS SHEET
7'-0"
3
1 2
"
(2) 2X12: ANCHOR TOP
2X12 TO STL PLATES
4" RUBBER WALL BASE
(BOTH SIDES)
INFILL VOID AT
UNDERSIDE OF EXG 3'-4"L
PRECAST LINTEL W/ CMU
Set Issue:
ISSUED FOR BID
STRUCTURAL ELEVATION
1/2" = 1'-0"
1
FINISHES NOT SHOWN FOR CLARITY
STRUCTURAL SECTION
1" = 1'-0"
2
FINISHES NOT SHOWN FOR CLARITY
SECTION
3/4" = 1'-0"
3