squirtle squad - weebly

31
Picture source: SJRWMD and Nintendo ENV4514C | Lab Portfolio | April 17, 2016 Squirtle Squad JOSHUA BENJAMIN, GINA CASSULO, KEVIN KIJANKA, JISOO KIM

Upload: others

Post on 07-Apr-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Picture source: SJRWMD and Nintendo

ENV4514C | Lab Portfolio | April 17, 2016

Squirtle Squad JOSHUA BENJAMIN, GINA CASSULO, KEVIN KIJANKA, JISOO KIM

Executive Summary Gaineslando, Florida, is an up-and-coming city located on the banks of the St Johns River. With an established population of 130,000 people, the city is expected to grow up to 289,000 by the year 2036. Because of these needs, the city has enlisted the services of Squirtle Squad, Inc. to build a large enough drinking water plant to accommodate the water needs of the city for years to come. One goal of this project is to sustain the city’s water use while limiting the impact on the local environment and hydrology. To achieve this, it was determined that the best option for maximizing available water and minimizing impact on environment would be to draw water directly from the St. Johns River. Unlike the majority of cities in Florida that draw their water from the ground, Gaineslando will draw from surface water. Because of this, certain treatment processes will need to be put in place to handle pollutants and pathogens from the St. Johns River. Due to the high turbidity of the water and amount of particulate matter, rapid mix and flocculation will be key first processes in treating influent water. Due to the negative charge of many of the silt and clay particles, it will need to be treated with alum. After a residence time of 30 seconds, the solution will then be deposited into the flocculation basin where the particles will coagulate over a period of 36 minutes. After coagulating, the particles will need time to settle out. It was determined that the size of all 34 sedimentation basins should be 19,200 ft3, resulting in a total volume of 652,800 ft3. This is based on the daily intake rate necessary for the city and the time required for the particles to settle. After settling out, the water will need to pass through a granular media filter. This process will remove any remaining floc, some of the microorganisms including Giardia and Cryptosporidium, algae, and silt from the water. These filters will be backwashed every 24 hours in an order such that only one is offline at any given time. Afterward, the filtered water will pass through reverse osmosis treatment to remove any solutes from the water. All waste from both the backwash and reverse osmosis processes will be placed in a storage lagoon. Unlike the case of groundwater treatment, pathogens such as Cryptosporidium and Giardia must be accounted for. To handle this and other requirements set forth by the EPA, the water will be disinfected by traveling throughout a baffled basin. This stage will consist of nine 11,500 ft3 basins with a residence time of 30 minutes. Each basin will consist of 17 baffles to ensure thorough treatment of the water. Gaineslando has requested the design and construction of a wastewater treatment plant in addition to the water treatment plant. The city has outsourced most of the design to Wartortle Water Solutions, but has given Squirtle Squad, Inc. responsibility for designing the equalization basin. The equalization basin will allow the wastewater plant to take a variable input and convert it into a constant discharge for the rest of the plant.

1 | P A G E

Introduction

With a current population of 130,000, the city of Gaineslando has grown at a rate of 39.9% over the

past ten years, similar to its neighboring city of Sanford (Demographics, 2o1o). If this growth rate

persists, the population will reach 289,000 in the next 20 years. Because of this, the city has

contracted Squirtle Squad, Inc. to design a water treatment plant to treat a flow of 28.9 MGD. The

plant will be composed of rapid mix, flocculation, sedimentation, filtration, reverse osmosis, and

disinfection, with waste handling handled through lagooning. This report also includes the

equalization basin design for the wastewater plant that is currently being designed by Wartortle

Water Solutions.

Rapid mix is a system after ozonation and before flocculation crucial for removing suspended

matter in water. A coagulant helps in removing the unnecessary matter. This system offers a quick

dispersion of the coagulant and the coagulants react with the particles in the water to facilitate the

binding of the particles with each other. This step is important to water treatment because it

reduces the alum concentration to about 80% of the original concentration in raw water.

Flocculation is the process that typically occurs after rapid mix. Typically, a flocculation tank is

separated into multiple stages, where the fluid is gradually slowed down in each tank by horizontal

paddle mixers. It is important to water treatment because it is the process by which fine particles

are caused to clump together into a floc.

Sedimentation is a crucial step in the treatment of drinking water. The key to good sedimentation

is time. By allowing the floc containing water to travel slowly through a large basin, the floc is

allowed to settle out. Also, by moving the water slowly through the basin, floc disruption is

minimal.

Filtration is a key process in drinking water treatment. It is a necessary process because it removes

smaller particles from the water that cannot settle out during the sedimentation stage. Because of

this, filtration follows sedimentation in the drinking water treatment process. The suspended

particles that are removed during filtration can consist of floc, microorganisms including Giardia

and Cryptosporidium, algae, and silt.

Reverse osmosis (RO) membrane filtration is meant to separate dissolved solids from water by

forcing water through a semi-permeable membrane. RO involves the forced passage of water

through a semi-permeable membrane against natural osmotic pressure, and is typically used to

remove dissolvable solutes from the water, such as Na+, Cl-, Ca2+, and Mg2+.

Water disinfection is the removal or inactivation of pathogenic microorganisms. It is usually

considered the most important phase of water treatment because the termination of growth and

reproduction of the microorganisms can prevent infection and illness from drinking untreated

water.

The residuals from the water treatment will be treated using lagooning, as it is an accepted method

for dewatering, thickening, and storage of waste sludge. The lagoon uses the process of air drying,

where the waste is spread out in a shallow area and allowed to dewater through evaporation.

An equalization basin is designed to convert a variable input flow rate into a constant discharge. It

is necessary in a wastewater plant because the input that goes into a wastewater plant can come

from a multitude of sources, whose flow rates can vary both temporally and spatially.

2 | P A G E

Lab 1

Raw Water Source

Population Projection

The city of Gaineslando, Florida, with a current population of 130,000, has grown at a rate of 39.9%

over the past ten years, similar to its neighboring city of Sanford (Demographics, 2o1o). If this

growth rate persists, the population will reach 289,000 in the next 20 years. Since the average water

consumption per person per day is 100 gallons, the projected water demand in 20 years will be 28.9

MGD. The Gaineslando water treatment plant will be designed according to this projected flow.

Why the St. Johns River?

Continual population growth and expanding development in Gaineslando and the rest of Central

Florida brings with it an increasing demand for potable water, which in turn creates greater strain

on the groundwater resources currently in use. The primary motivation for selecting the St. Johns

River (SJR) as a raw water source for this water treatment plant is to reduce reliance on the aquifer,

which otherwise might face irreversible saltwater intrusion if overdrawn.

According to a Water Supply Impact Study of the river, as much as 155 MGD could be drawn from

the SJR with little to no ecological impact. The projected volume per day of this plant (28.9 MGD)

falls well below the study’s threshold for moderate impacts, so the operation of this plant would

more than likely have negligible to minor water level and ecological impacts both locally and

downriver, where salinity and discharge effects would only result from a much higher withdrawal

volume (Lowe, 2012).

The main disadvantages, however, to using a surface water like the SJR lie in the variability of the

flow according to season and in case of drought. Concentrations of many constituents can fluctuate

greatly with seasonal or weather-related changes. Furthermore, in the event of very low flow, there

is a possibility that withdrawal from the SJR could have a more noticeable impact on the river

environment.

3 | P A G E

Constituents of Interest in the Raw Source Water

Table 1.1. Summary of raw water characteristics and primary/secondary drinking water treatment

standards

Constituent Level/Concentration (SJR) EPA Drinking

Standard** Standard

Met?

GENERAL

pH 8.10 6.5 - 8.5 Yes

Turbidity (NTU) 4.3 1 No

NUTRIENTS

Ammonia (mg/L as N) 0.028 N/A N/A

Chlorophyll-a (algae) (mg/L) 23.6 0.004 No

Total Nitrate (mg/L as N) 0.15 10 Yes

Nitrite (mg/L as N) < 0.01 1 No

Total Phosphorus (mg/L) 0.08 0.04 No

Dissolved Oxygen (DO) (mg/L) 8.186 5 Yes

ORGANIC

Color (CU) 80 15 No

DOC (mg/L) 16.9 See Turbidity/Color No

INORGANIC

Barium (mg/L) 28 2 No

Bromide (DBP) (mg/L) 0.93 0.01 (Bromate DB) No

Calcium (mg/L) 51 N/A N/A

Chloride (mg/L) 287 250 No

Total Iron (mg/L) 0.179 0.3 Yes

Magnesium (mg/L) 23 N/A N/A

Potassium (mg/L) 7.3 N/A N/A

Silica (mg/L) 4.0 N/A N/A

Sodium (mg/L) 186 250 Yes

Strontium (mg/L) 1.156 N/A N/A

Sulfate (mg/L) 78 250 Yes

Sulfide (mg/L) < 1 N/A N/A

Total Dissolved Solids (mg/L) 735 500 No

**Primary standards are highlighted in red and secondary standards are highlighted in blue.

Constituents to be removed to meet standards: turbidity, chlorophyll-a (algae), nitrite,

phosphorus, color, DOC, barium, bromide, and total dissolved solids.

4 | P A G E

Rapid Mix

Rapid mix is a system after ozonation and before flocculation crucial for removing suspended

matter in water. A coagulant helps in removing the unnecessary matter. This system offers a quick

dispersion of the coagulant and the coagulants react with the particles in the water to facilitate the

binding of the particles with each other. This step is important to water treatment because it

reduces the alum concentration to about 80% of the original concentration in raw water.

For this design, the rapid mix basin is a square and has dual flat-blade impellers and stator baffles.

It is assumed to be under the conditions of 1st order kinetics. The design started off with the

recommended parameters: residence time between 10 and 30 seconds, velocity gradient between

600 and 1000 s-1, and volume of the basin to be less than 26.25 ft3. Since the basin has the length to

width ratio of 1:1, the basin is designed to have the length of 4.92 ft to satisfy the volume limit of

26.25 ft3. With the basin length of 4.92 ft, the liquid depth, the baffle length, and the impeller

diameter can be determined using the recommended parameters.

πΏπ‘–π‘žπ‘’π‘–π‘‘ π‘‘π‘’π‘π‘‘β„Ž π‘“π‘œπ‘Ÿ π‘‘π‘’π‘Žπ‘™ π‘–π‘šπ‘π‘’π‘™π‘™π‘’π‘Ÿπ‘  = 4.92 𝑓𝑑 Γ— 1.5 = 7.38 𝑓𝑑

π΅π‘Žπ‘“π‘“π‘™π‘’ π‘™π‘’π‘›π‘”π‘‘β„Ž = 4.92 ft Γ— 10% = 0.492 𝑓𝑑

πΌπ‘šπ‘π‘’π‘™π‘™π‘’π‘Ÿ π‘‘π‘–π‘Žπ‘šπ‘’π‘‘π‘’π‘Ÿ π‘“π‘œπ‘Ÿ π‘‘π‘œπ‘’π‘π‘™π‘’ π‘–π‘šπ‘π‘’π‘™π‘™π‘’π‘Ÿ = 4.92 ft Γ— 0.5 = 2.46 𝑓𝑑

π‘‰π‘œπ‘™π‘’π‘šπ‘’ π‘œπ‘“ 1 π‘π‘Žπ‘ π‘–π‘›, 𝑉1 = π‘™π‘€β„Ž = 4.92 ft Γ— 4.92 ft Γ— (7.38 + 1) 𝑓𝑑 = 202.85 𝑓𝑑3

For the volume of one basin, the height is determined by adding the liquid depth and the

freeboard per tank, which is 1ft. The velocity gradient and the residence time are designed to be 700

s-1 and 30 s, respectively. Then, the mixer power requirements and the flow rate per one basin can

be determined. Here, water is assumed to be at 18Β°C and the dynamic viscosity of the water at the

respective temperature is Β΅ = 0.022 lbfΒ·s/ft2

π‘‰π‘’π‘™π‘œπ‘π‘–π‘‘π‘¦ π‘”π‘Ÿπ‘Žπ‘‘π‘–π‘’π‘›π‘‘, 𝐺 = βˆšπ‘ƒ

πœ‡ βˆ™ 𝑉1

π‘ƒπ‘œπ‘€π‘’π‘Ÿ π‘Ÿπ‘’π‘žπ‘’π‘–π‘Ÿπ‘’π‘‘, 𝑃 = 𝐺2πœ‡π‘‰1 = 7002 π‘ βˆ’2 Γ— 0.022 𝑙𝑏𝑓 βˆ™ 𝑠

𝑓𝑑2Γ— 202.85 𝑓𝑑3 = 2186723

𝑓𝑑 βˆ™ 𝑙𝑏𝑓

𝑠

= 2.18 Γ— 106 𝑓𝑑 βˆ™ 𝑙𝑏𝑓

𝑠

To obtain the flow rate of one basin, the following calculation must be done.

πΉπ‘™π‘œπ‘€ π‘Ÿπ‘Žπ‘‘π‘’ π‘œπ‘“ 1 π‘π‘Žπ‘ π‘–π‘›, 𝑄1 =𝑉1

𝑑=

202.85 𝑓𝑑3

30 𝑠= 6.76

𝑓𝑑3

𝑠

The total flow rate, Q, for the design is 28.9 MGD. The conversion from MGD to m3/s is as follows.

𝑄 =28.9 Γ— 106π‘”π‘Žπ‘™

1 π‘‘π‘Žπ‘¦Γ—

1 π‘‘π‘Žπ‘¦

24 β„Žπ‘ŸΓ—

1 β„Žπ‘Ÿ

60 π‘šπ‘–π‘›Γ—

1 π‘šπ‘–π‘›

60 𝑠×

0.134 𝑓𝑑3

1 π‘”π‘Žπ‘™= 44.82

𝑓𝑑3

𝑠

π‘π‘’π‘šπ‘π‘’π‘Ÿ π‘œπ‘“ π‘‘π‘Žπ‘›π‘˜π‘  =𝑄

𝑄1

=44.82

6.76= 6.63 β‰ˆ 7 π‘‘π‘Žπ‘›π‘˜π‘ 

5 | P A G E

Therefore in total, the rapid mix design requires 7 tanks to satisfy the water required for the

population.

π΅π‘Žπ‘“π‘“π‘™π‘’ π‘£π‘œπ‘™π‘’π‘šπ‘’ = β„Ž Γ— π‘π‘Žπ‘“π‘“π‘™π‘’ π‘™π‘’π‘›π‘”π‘‘β„Ž Γ— 𝑀 = 8.38 Γ— 0.492 Γ— 4.92 𝑓𝑑3 = 20.28 𝑓𝑑3

Table 1.2. Summary of design parameters for rapid mix basins

Parameter Recommended Actual

Total Flow Rate (Q) 44.82 ft3/s

Residence Time (t) Between 10 and 30 seconds 30 s

Velocity Gradient (G) Between 600 – 1000 s-1 700 s-1

Total Volume of basins (V) 1419.74 ft3

Volume per basin Less than 8 m3 202.85 ft3

Number of basins 7

Baffles:

Number of baffles 2 2

Baffle Length Extend 10% of basin width 0.492 ft

Baffle Volume 20.28 ft3

Impellers:

Number of impellers 2 2

Diameter of impellers 0.3 – 0.5 times the basin width 2.46 ft

Volume of impellers 31.08 ft3

Length per basin 4.92 ft

Width per basin 4.92 ft

L:W ratio 1:1 1:1

Height per basin

Liquid depth per tank 1.1 – 1.6 times the basin width 7.38 ft

Freeboard per tank 1 ft 1 ft

6 | P A G E

Figure 1.1. Schematic of rapid mix basin

7 | P A G E

Flocculation

Flocculation is the process that typically occurs after rapid mix. Typically, a flocculation tank is

separated into multiple stages, where the fluid is gradually slowed down in each tank by horizontal

paddle mixers. It is important to water treatment because it is the process by which fine particles are

caused to clump together into a floc. How it works is that it reduces the flow velocity that occurs

after rapid mix, and causes the colloids to stabilize and bind together into flocs. During flocculation,

the chemically treated water is given gentle, slow mixing to build large settleable floc. Once the floc

is formed, the water is moved into the sedimentation basin, where the floc can settle on the bottom

of the basin and be removed from the water.

In this design, the flocculation basin consists of five separate flow lines running in parallel, with each

flow line separated into three basins.

The time was assumed to be 36 seconds due to the ease with which it can be divided into 3, as well

as the increased travel time aiding the flocculation process. Using the time, the volume can be

calculated as:

βˆ€= 𝑑𝑄 = 36π‘šπ‘–π‘› βˆ— 28.9𝑀𝑔𝑑 = 96,815 ft3

This gives the total volume for the entire system, which can then be divided by 15 to find the volume

per basin, which is 6,454.3 ft2. Each basin has a corresponding lower value of G, and is designed to

slow the fluid flow and move it using large horizontal paddles. The power requirements and paddle

velocities were calculated based off of the G values, with CD = 1.8, and ρ = 1.936 slugs/ft3. Each basin

contains four sets of paddles, that each have four arms that contain two paddles each. Paddle

dimensions and spacing were determined by consulting the coagulation and flocculation chapter of

β€œTheory and Practice of Water and Wastewater Treatment” by Ronald L. Droste (Droste, 1994), which

identified the ideal spacing for paddles from the wall as 0.66 ft. and the ideal spacing between paddles

as 0.98 ft.

The reason why the design uses five set separate flow lines is due to the demand for water not being

at peak capacity until year 20, which means that when the plant opens it will not have to run all of

the basins. Furthermore, separate flow lines allows for a degree of redundancy, in that if a line

malfunctions for some reason, the flow will be able to be rerouted to another line while the faulty

line can be replaced.

Note that calculations for design parameters can be found in the sample calculations at the end of

the report.

8 | P A G E

Table 1.3. Summary of design parameters for flocculation basins

Parameter Recommended Actual

Total Flow Rate (Q) - 28.9 Mgd

Residence Time (t) > 30 min 36 mins

Total Volume of basins (V) - 96,815 ft3

Volume per basin - 6,454.3 ft3

Number of basins - 15

Horizontal Flow Velocity Between 0.5 – 1.5 ft/min 1 ft/min

Speed of paddles Between 0.5 to 3.0 ft/s Varies per zone

Total Length - 36 ft

Total Width 0.2 – 0.5 times the paddle diameter

225 ft

L:W ratio 20:1 for flat blades 20:1

Zone 1

Velocity Gradient (G) - 60 s-1

Horizontal Flow Velocity - 1 ft/min

Paddles: Four sets of paddles/basin

Diameter of paddles - 10.68 ft

Length of paddles - 9.93 ft

Width of paddles - .5 ft

Distance between paddles - 1.31 ft

Length per zone - 12 ft

Width per zone - 45 ft

Height per zone - 13.6 ft

Liquid depth per zone - 12 ft

Freeboard per zone 1 ft 1.6 ft

Power requirements - 0.767 hp

Paddle Velocity - 2.9 ft/s

Zone 2

Velocity Gradient (G) - 45 s-1

Horizontal Flow Velocity - 1 ft/min

Paddles: Four sets of paddles/basin

Diameter of paddles - 10.68 ft

Length of paddles - 9.93 ft

9 | P A G E

Width of paddles - .5 ft

Distance between paddles - 1.31 ft

Length per zone - 12 ft

Width per zone - 45 ft

Height per zone - 13.6 ft

Liquid depth per zone - 12 ft

Freeboard per zone 1 ft 1.6 ft

Power requirements - 0.432 hp

Paddle Velocity - 2.39 ft/s

Zone 3

Velocity Gradient (G) - 30 s-1

Horizontal Flow Velocity - 1 ft/min

Paddles: Four sets of paddles/basin

Diameter of paddles - 10.68 ft

Length of paddles - 9.93 ft

Width of paddles - .5 ft

Distance between paddles - 1.31 ft

Length per zone - 12 ft

Width per zone - 45 ft

Height per zone - 13.6 ft

Liquid depth per zone - 12 ft

Freeboard per zone 1 ft 1.6 ft

Power requirements - 0.192 hp

Paddle Velocity 1.83 ft/s

10 | P A G E

Figure 1.2. Schematic of flocculation basin

11 | P A G E

Sedimentation

Sedimentation is a crucial step in the treatment of drinking water. The key to good sedimentation

is time. By allowing the floc containing water to travel slowly through a large basin, the floc is

allowed to settle out. Also, by moving the water slowly through the basin, floc disruption is

minimal.

Particles settle out due to gravity and the time it takes them to settle is based on their settling

velocity. Larger particles will have a greater settling velocity and settle out much quicker than the

smaller particles. By the time the water reaches the end of the basin, many of the large particles will

settle out, leaving a small amount of finer particles which will need to be removed through

filtration processes. Without sedimentation, the floc particles generated during the flocculation

stage would not be removed from the water that is outputted. These floc particles could then

become disrupted and break apart and clog future clarification processes (i.e. filtration).

For the sedimentation basin designs, a rectangular basin was decided upon due to the fact it

minimizes short-circuiting when compared to circular basins. The residence time of each of the

basins was decided to be a total of 4 hours. This value was decided upon because it fell within the

acceptable range. Other values that were decided based on whether or not they fell within the

acceptable range included width, liquid depth, L:W ratio, and freeboard. After deciding that the

width would be 20 feet and L:W would be 6 to 1 it could be determined that the length is 120 feet.

Based on these values the volume of each basin can be determined by multiplying width by height

by depth resulting in 19200 ft3. Once the volume was determined, equation 1 in the sedimentation

section of the sample calculations was used determine the number of basins required based on

values already determined.

Though this number of tanks may appear high, it is necessary based on the other parameters of the

basin. Once the number of basins has been determined, it can be multiplied by the volume of each

basin to determine the total volume of basins.

The surface area can be determined by multiplying the width of each basin by its length. The flow

area can be determined by multiplying the width of a single basin by the height. Once the flow area

has been determined it can be used in the determination of horizontal flow velocity. This is

calculated in equation 2. The overflow velocity can be calculated by using the surface area of a

single sedimentation basin. This is calculated in equation 3. Both the flow velocity and the

overflow velocity fall within the recommended values.

The weir loading was decided to be 20,000 gal/dayβ€’ft. Once this was determined, the total weir

length was calculated through the use of equation 4. The resulting value of 42.5 ft for the total weir

length is appropriate even though it fails to result in a finger weir length of 39.6 ft that is 33% of the

total basin length. The total weir loading is far more important than the finger weir length, which is

only 9.4% of the total basin length. Finger weir length can be calculated based on total weir length

and the width of the basin. This is shown in equation 5. In this equation, the number of fingers is

taken to be two because this results in the maximum finger weir length that follows the weir

loading.

12 | P A G E

Table 1.4. Summary of design parameters for sedimentation basins showing both recommended

and actual values.

Parameter Recommended Actual

Total Flow Rate (Q) 28.9 MGD

Residence Time (t) 4 – 8 hrs. 4 hr

Total Volume of basins (V) 652800 ft3

Volume per basin 19200 ft3

Number of basins 34

Length per basin 120 ft

Width per basin 10 – 20 ft 20 ft

L:W ratio 3:1 to 6:1 6 : 1

Height per basin

Liquid depth per tank 7 – 8 ft 8 ft

Freeboard per tank 1 ft 1 ft

Surface area 2400 ft2

Flow area 160ft2

Horizontal Flow Velocity ≀ 0.5 ft/min .49318 ft /min

Overflow Velocity Between 350 – 800 gal/dayβ€’ft2 354.166 gal/day*ft2

Weirs:

Number of finger weirs 2

Finger Weir Length 33% of total basin length 11.25 ft

Total Weir Length 42.5 ft

Total Weir Loading 20,000 gal/dayβ€’ft 20,000 gal/day*ft

13 | P A G E

Figure 1.3. Schematic of sedimentation basin (side view and top view)

14 | P A G E

Lab 2

Granular Media Filtration

Filtration is a key process in drinking water treatment. It is a necessary process because it removes

smaller particles from the water that cannot settle out during the sedimentation stage. Because of

this, filtration follows sedimentation in the drinking water treatment process. The suspended

particles that are removed during filtration can consist of floc, microorganisms such as Giardia and

Cryptosporidium, algae, and silt.

To remove these particles, overflow from the sedimentation stage is allowed to filter through a

column of granular media. This media generally consists of layered sand and gravel below a top

layer of anthracite coal or a similar substance. The filter media should have a large amount of

surface area relative to its volume. The surface of the media should be course with large pore

openings to retain a large amount of floc and small enough to not let larger particles through. The

depth of the media should be enough to allow for long filter runs. This is because as water passes

through the media, the concentration of useable media decreases and the parts that are useable

become concentrated with particles. As the clean bed depth shrinks, breakthrough can eventually

occur where particles begin to stream into the outflow.

Flow through the filter media is driven by gravity. At the beginning of the filtration process, the

water is able to easily flow through the media. To prevent an excessive flow rate through the media

while the filter is clean, the output velocity is controlled. As the filter media begins to increase in

particle concentration, the resistance in flow increases and the output velocity can be increased

accordingly. Once the filter becomes fully concentrated with particle matter, backwash is

performed to clean the media material.

First, through equation 1, Gaineslando’s flow rate of 28.9 MGD was converted into 20,069.44 gpm.

Assuming a loading rate of 5.97 gpm/ft2 (trial and error calculation showed that this value resulted

in cleaner dimension values), which falls within the recommended range of 3-6 gpm/ft2, the total

necessary filtration surface area was determined to be 3364ft2 by equation 2. This total surface

area was segmented into 16 square-based basins with length and width equaling 14.5 ft.

A common setup of sand topped with anthracite was chosen for the filter media. Having the

anthracite come into contact with the water first allows for greater adsorption of the suspended

particles due to anthracite’s large pore size. This allows fewer particles to reach the sand layer,

which can cause plugs in the filter. The depth of the weir to media was selected to be 3 ft based on

the recommended value and the fact that there should be enough water above the media to keep

the water easily flowing through the media. The depths of sand and anthracite were determined to

be 1 and 2 ft, respectively, based on the recommended values. The depth of the anthracite should be

greater than that of the sand because of its greater pore size and its ability to capture more

particles. It is placed first in the media order to prevent the sand from clogging.

15 | P A G E

Table 2.1. Summary of design parameters for granular-media filtration

Parameter Recommended Actual

Total Flow Rate (Q) 28.9 MGD

Loading Rate 2-10 gpm/ft2; 3-6 gpm/ft2 is common

5.97 gpm/ft2

Total Volume of basins (V) 30276 ft3

Volume per basin 1892.25 ft3

Number of basins 16

L:W ratio 1:1 1:1

Length per basin 14.5 ft

Width per basin 14.5 ft

Height per basin ~10 ft 9 ft

Freeboard per tank ~2 ft 2 ft

Distance from top of media to bottom of weir

~3 ft 3 ft

Depth of underdrain ~1 ft 1 ft

Depth of sand ~1 ft 1 ft

Depth of anthracite coal ~2 ft 2 ft

Figure 2.1. Schematic of Filter Basin (cross-section)

Reverse Osmosis (RO) Membrane Filtration

Reverse osmosis (RO) membrane filtration is meant to separate dissolved solids from water by

forcing water through a semi-permeable membrane. RO involves the forced passage of water

through a semi-permeable membrane against natural osmotic pressure, and is typically used to

remove dissolvable solutes from the water, such as Na+, Cl-, Ca2+, and Mg2+. The dissolved solutes

are then removed from the system and stored as a brine. Next, the brine is sent away for disposal,

which is typically done through either surface water discharge, an evaporation pond, through land

application, deep well injection, sewer discharge, dust control, or for deicing.

RO is important to water treatment because it is the final filtration step before disinfection (the

reason for this is to prevent RO from removing the Cl that is added in the disinfection stage), that

is able to remove solutes. It is important to keep the turbidity below 1 NTU in order to prevent

membrane fouling. If the turbidity is any higher than 1 NTU, too many suspended particles will

settle on the membrane surface, thus blocking feed channels and increasing friction losses across

the system.

For a RO membrane to properly function, the osmotic pressure must be in the range of 350 to 800

psi. The range depends mainly on the solute concentrate of the feed, with higher pressures required

for higher concentrates. The Gaineslando Water Treatment plant will use the Vantage M86 reverse

osmosis and nanofiltration system, Model No. M86R-162. In regard to TDS, the raw water taken

from the St. Johns River has a TDS of 735 ppm. The Vantage M86 is optimized for water chemistries

with 250 ppm ≀ TDS ≀ 2000 ppm, which makes it an ideal solution. This system is a single-pass

filter, which pushes the feed water through a semi-permeable membrane to create a supply of reject

water (brine) and product water. This system has the capacity to remove 97% of TDS and 95% of

naturally occurring organics. The main disadvantage of this system is that it has a high water loss of

20% (assume that the brine is sent to an evaporation pond, where the evaporated water is captured

and sent back into the system for treatment, effectively minimizing the total loss). This is due to

the high pressure that is provided by the pump, which is a 316 SS high pressure pump. The pump

can provide up to 516 psi, which is more than enough for the recommended pressure of 150-300 psi.

In regard to pH, the pH from the St. Johns River is already within the allowable values, at 8.1. For

chlorine, the level that is in the St Johns is 287 ppm. Assuming that the removal rate for TDS

matches the removal rate for chlorine, this gives a final value of 8.43 ppm, which is below the EPA

secondary standard of 250 ppm. This plant will require 21 RO units, which was determined by

dividing the total plant flow (20,069.44 gpm) by the flow per unit (960 gpm) (see Equation 1).

17 | P A G E

Table 2.2. Summary of design parameters for reverse osmosis membrane units

Parameter Recommended Actual

Total Flow Rate (Q) 28.9 MGD

Number of membrane units 21

Operating Pressures 150 – 300 psi (1035 – 2400 kPa) 300 psi

Allowable pH pH 4 – pH 11 8.1

Maximum allowable chlorine 0.1 mg/L 8.43

Maximum allowable turbidity ≀ 1 π‘π‘‡π‘ˆ 1

Water loss percentage 20%

Figure 2.2. Schematic of single reverse osmosis unit

18 | P A G E

Disinfection

Water disinfection is the removal or inactivation of pathogenic microorganisms. It is usually

considered the most important phase of water treatment because the termination of growth and

reproduction of the microorganisms can prevent infection and illness from drinking untreated

water. The disinfection stage includes physical and chemical disinfections. The disinfecting agents

added to water bind or chemically remove the microorganisms and can remain in the water as a

residual to prevent any further growth of the unwanted microorganisms.

Using Equation 1, a total water volume of 80,487 ft3 was determined to be necessary for a

recommended residence time of 30 minutes. This needed water volume can be divided into about 8

10,000 ft3 segments of equal dimensions (100 ft x 10 ft x 10 ft) (Equation 2) before taking into

account baffle volume and freeboard. Each 1oo-foot-long basin will contain 17 baffles (11.5 ft (total

height including freeboard) x 0.5 ft (thickness) x 7 ft (width)), which together take up a

submerged volume of 595 ft3 per basin (Equation 3). The baffles therefore reduce the water

capacity of each basin to 9,405 ft3, which increases the number of total necessary basins to 9

(Equation 4). Adding 1.5 ft of freeboard to the depth each basin structure brings the total volume

per basin to 11,500 ft3.

The EPA requires that surface water be treated to achieve 2-log (99%) removal of Cryptosporidium,

3-log (99.9%) removal of Giardia, and 4-log (99.9%) removal of viruses. Generally, if necessary CT

(chlorine dose x t10 time) is met to achieve 3-log Giardia removal, appropriate removal of

Cryptosporidium and viruses will also be met. Conventionally, 2.5-log removal of Giardia will occur

during filtration, meaning 0.5-log removal is necessary during the disinfection stage. The CT

required for 0.5-log removal of Giardia using free chlorine at a temperature of 20oC and a pH of 8

(raw SJR pH is 8.1) is 14 mg/L*min. The necessary chlorine dose for this plant’s flow can be

determined using this CT value and the t10 time, which is the time it takes for 10% of the water

entering the tank to be discharged. Due to the influence of baffling on the flow, the t10 time must be

determined using a tracer study during peak hourly flow.

19 | P A G E

Table 2.3. Summary of design parameters for disinfection

Parameter Recommended Actual

Total Flow Rate (Q) 28.9 MGD

Residence Time (t) 30 minutes 30 minutes

Total Volume of basins (V) 80,487 ft3

Volume per basin 11,500 ft3 (total)

9,405 ft3 (water)

Number of basins 9

Baffles:

Number of baffles 17

Baffle Length (total, including freeboard)

11.5 ft

Baffle Volume (submerged only)

595 ft3

Length per basin 100 ft

Width per basin 10 ft

L:W ratio 10:1

Height per basin 11.5 ft

Liquid depth per tank 10 ft

Freeboard per tank 1.5 ft

Figure 2.3. Schematic of disinfection basin

20 | P A G E

Water Treatment Residuals/Waste Handling

The water treatment residuals that are present in our system are from sedimentation, granular

media filtration, and reverse osmosis.

The residual that is generated from sedimentation is from colloidal matter removed from the raw

water and chemical flocs that initially pass through this stage. A large component of this waste is

alum, which is the chemical flocculent that was initially injected in the rapid mix phase. The sludge

residuals can be estimated from chemical additions and raw water characteristics, and are

estimated based on Equation 1.

The majority of the sludge solids formed during this stage settle on the bottom of the

sedimentation basin, and the remainder are removed by filtration.

The residual generated by the granular media filtration stage is the filter wash water. This facility’s

filters will be backwashed every 24 hours. They should be backwashed at off-peak hours when the

downtime will not affect the required output flow. Based on information from Hammer and

Hammer, a backwash rate commonly used is 15 gpm/ft2. This backwash rate and the plant’s

filtration surface area of 3364 ft2 would result in a flow of 50,460 gpm (Equation 2). It is generally

recommended that the total amount of water used for backwashing is 2-3% of our total water

output. After 12 minutes, 605,520 gallons would be used to backwash the media which is 2.1% of the

total output (Equation 3). After the filtration media has been properly cleaned, before water

treatment resumes it is important that any water that is filtered through during the first 3-5

minutes be wasted.

Residuals from reverse osmosis are predominately from the brine that is generated from the reject

water. At peak flow rates, the brine can be up to 20% of the feed water, which accounts for

approximately 5.78 MGD.

The residuals from the water treatment will be treated using lagooning, as it is an accepted method

for dewatering, thickening, and storage of waste sludge. The lagoon uses the process of air drying,

where the waste is spread out in a shallow area and allowed to dewater through evaporation. Once

the waste has been properly dewatered, it can then be collected and sent to a dedicated surface

disposal site, with the residuals from the sedimentation basin and granular media filtration sent to

a sludge handling site, and the brine residuals sent up north during the winter to be used for

deicing, or sent to the surface disposal site when deicing is not a viable option.

Table 2.4. Summary of waste handling

Waste Source Volume Handling Method

Sedimentation 99.93 lb/mil gal Lagooning and surface disposal

Granular Media Filtration 0.87 mgd Lagooning and surface disposal

Reverse Osmosis Filtration 5.78 mgd Lagooning and surface disposal, with residuals sent for deicing when appropriate

21 | P A G E

Lab 3

Equalization Basin

An equalization basin is designed to convert a variable input flow rate into a constant discharge. It

is necessary in a wastewater plant because the input that goes into a wastewater plant can come

from a multitude of sources, whose flow rates can vary both temporally and spatially. In a typical

wastewater operation, it is part of the pretreatment phase. It comes after the bar rack and the grit

chamber, and before primary settling. The objective of equalization is to minimize or control

fluctuations in wastewater characteristics in order to provide optimum conditions for subsequent

treatment processes. This system utilizes in-line equalization, as it is an effective method for

leveling out the variations in influent concentration. This is because the entire flow is blended with

the entire contents of the holding tank by the use of diffused air that is pumped into the basin,

which allows for the water to be aerated and begin the wastewater treatment process.

One purpose of an equalization basin is to reduce the mass loading of BOD through mixing and

aeration. Biochemical oxygen demand (BOD) is a parameter that measures how much oxygen

would be consumed by all the bacteria and protozoa if all of the organics were oxidized in a

wastewater sample. It is the quantity of oxygen utilized by a mixed population of microorganisms

in the aerobic oxidation of the organic matter in a sample of wastewater at a temperature of 20 ⁰C ±

1⁰C in an air incubator or water bath. The standard test for BOD is BOD5, which has an incubation

period of 5 days at 20⁰. It is an effective measure to assess the effectiveness of current water

treatment processes, as it provides an empirical measure of the level of degradable organic material

in a body of water. Furthermore, it estimates the relative oxygen consumption of wastewaters,

effluents, and other waters affected by organic pollution.

The design utilizes a trapezoidal shaped basin. This creates a constant source of head, since the input flow is at the top of the basin and the output flow is at the bottom of the basin. This is important, as it allows the basin to properly drain even when there is a power outage. In order to evaluate the impact of equalization on the mass loading of BODs, the flow rate must be converted to volume in:

π‘‰π‘œπ‘™π‘’π‘šπ‘’ 𝑖𝑛 = π‘“π‘™π‘œπ‘€ Γ— π›₯𝑑 Γ—3600𝑠

1β„Ž[=]π‘š3

With the volume in values for the 24 hours, volume out can be calculated by averaging the volume in:

π‘‰π‘œπ‘™π‘’π‘šπ‘’ π‘œπ‘’π‘‘ =π›΄π‘‰π‘œπ‘™π‘’π‘šπ‘’ 𝑖𝑛

24[=]π‘š3

Then the change in storage for each time period is calculated as follows:

πΆβ„Žπ‘Žπ‘›π‘”π‘’ 𝑖𝑛 π‘ π‘‘π‘œπ‘Ÿπ‘Žπ‘”π‘’, 𝛿𝑆 = π‘‰π‘œπ‘™π‘’π‘šπ‘’ 𝑖𝑛 βˆ’ π‘‰π‘œπ‘™π‘’π‘šπ‘’ π‘œπ‘’π‘‘ [=]π‘š3

The cumulative sum is the addition of the change in storage of the previous term and the change in storage of the term:

πΆπ‘’π‘šπ‘’π‘™π‘Žπ‘‘π‘–π‘£π‘’ π‘†π‘’π‘š, 𝛴𝛿𝑆 = π›΄π›Ώπ‘†π‘‘βˆ’1 βˆ’ 𝛿𝑆𝑑[=]π‘š3

22 | P A G E

The mass of BOD and the storage average are determined with the equations below:

π‘€π‘Žπ‘ π‘  π‘œπ‘“ 𝐡𝑂𝐷𝑠, π‘€π΅π‘‚π·βˆ’π‘–π‘› = π‘‰π‘œπ‘™π‘’π‘šπ‘’ 𝑖𝑛 Γ— 𝐡𝑂𝐷 Γ—1000𝐿

π‘š3Γ—

1𝑔

1000π‘šπ‘”Γ—

1π‘˜π‘”

1000𝑔[=]π‘˜π‘”

π‘†π‘‘π‘œπ‘Ÿπ‘Žπ‘”π‘’ π‘Žπ‘£π‘’π‘Ÿπ‘Žπ‘”π‘’, π‘†π‘Žπ‘£π‘” =(𝑉𝑖)(π‘†π‘œ) + (𝑉𝑠)(π‘†π‘π‘Ÿπ‘’π‘£)

𝑉𝑖 + 𝑉𝑠

[=]π‘šπ‘”

𝐿

Where,

𝑉𝑖= volume inflow during time interval π›₯𝑑 [=]π‘š3

π‘†π‘œ= average BODs concentration during π›₯𝑑 [=]𝑔

π‘š3

𝑉𝑠= volume of wastewater in basin at the end of the previous time interval [=]π‘š3

π‘†π‘π‘Ÿπ‘’π‘£= previous π‘†π‘Žπ‘£π‘”[=]𝑔

π‘š3

π‘€π‘Žπ‘ π‘  π‘œπ‘“ 𝐡𝑂𝐷 π‘œπ‘’π‘‘, π‘€π΅π‘‚π·βˆ’π‘œπ‘’π‘‘ = π‘†π‘Žπ‘£π‘” Γ— π‘‰π‘œπ‘™π‘’π‘šπ‘’ π‘œπ‘’π‘‘ [=]π‘˜π‘”

Figure 3.1. Schematic of equalization basin

23 | P A G E

Discussion/Conclusion

The water treatment facilities in Gainesville have been touted as some of the best water treatment

facilities in Florida. These plants are well designed, and as such are ideal candidates for

comparison. Comparisons will be made with the Murphree Water Treatment Plant for the water

treatment component of our design, and the UF Water Reclamation Facility being compared to the

Wastewater component of our design.

There are several similarities and differences between the Gaineslando Water Treatment Plant and

the Murphree Water Treatment Plant. The Murphree Plant currently treats up to 26 MGD with

permits allowing it to treat up to 30 MGD, while our plant is designed to treat 28.9 MGD. The main

difference between the two plants is that the Murphree plant relies on groundwater, while the

Gaineslando plant relies on surface water. The Murphree plant relies heavily on reducing the

hardness and alkalinity that is naturally found in groundwater. Because of this, it has many

processes that are not found in the Gaineslando Plant, such as lime softening and recarbonation.

Meanwhile, since the Gaineslando plant’s main source of water is surface water, it focuses on

removing suspended matter through rapid mix, flocculation, and reverse osmosis. Since

groundwater is a relatively clean source, the Murphree plant does not have to treat specifically for

Cryptosporidium and Giardia. The Murphree plant utilizes fluorination in order to improve the

dental health of the youth of Gainesville. However, the main demographic in Gaineslando is people

over 55, so we have deemed fluorination as an unnecessary process.

The similarities between the two plants are that both plants utilize some form of solute removal,

with the Murphree plant utilizing clarification, and the Gaineslando plant utilizing flocculation and

sedimentation. Both plants practice disinfection and filtration, with the main disinfection process

being chlorination, and the filters from both plants utilizing a combination of anthracite and sand.

In regards to the wastewater plants, the UF Water reclamation facility is a well-designed plant, and

will be a suitable model for the rest of the wastewater plant that is currently being designed by

Wartortle Water Solutions. However, since the equalization basin is provided in this design, it has

been deemed necessary to compare the attributes to the plant. One comparison that can be made is

that while the UF Water Reclamation facility did not have a designated equalization basin, it did

contain a splitter box leading to the anerobic and aerobic basins, which served the purpose of

equalizing the input flow that came after the pretreatment phase.

Appendix I – Lab 1 Sample Calculations

Population Projection:

𝑃𝑑 = π‘ƒπ‘œπ‘’π‘˜βˆ†π‘‘ = 130,000 π‘π‘’π‘œπ‘π‘™π‘’ βˆ— 𝑒39.9%

10 π‘¦π‘’π‘Žπ‘Ÿπ‘ β„ βˆ—2(10 π‘¦π‘’π‘Žπ‘Ÿπ‘ )= 289,000 π‘π‘’π‘œπ‘π‘™π‘’

Rapid Mix:

πΏπ‘–π‘žπ‘’π‘–π‘‘ π‘‘π‘’π‘π‘‘β„Ž π‘“π‘œπ‘Ÿ π‘‘π‘’π‘Žπ‘™ π‘–π‘šπ‘π‘’π‘™π‘™π‘’π‘Ÿπ‘  = 4.92 𝑓𝑑 Γ— 1.5 = 7.38 𝑓𝑑

π΅π‘Žπ‘“π‘“π‘™π‘’ π‘™π‘’π‘›π‘”π‘‘β„Ž = 4.92 ft Γ— 10% = 0.492 𝑓𝑑

24 | P A G E

πΌπ‘šπ‘π‘’π‘™π‘™π‘’π‘Ÿ π‘‘π‘–π‘Žπ‘šπ‘’π‘‘π‘’π‘Ÿ π‘“π‘œπ‘Ÿ π‘‘π‘œπ‘’π‘π‘™π‘’ π‘–π‘šπ‘π‘’π‘™π‘™π‘’π‘Ÿ = 4.92 ft Γ— 0.5 = 2.46 𝑓𝑑

π‘‰π‘œπ‘™π‘’π‘šπ‘’ π‘œπ‘“ 1 π‘π‘Žπ‘ π‘–π‘›, 𝑉1 = π‘™π‘€β„Ž = 4.92 ft Γ— 4.92 ft Γ— (7.38 + 1) 𝑓𝑑 = 202.85 𝑓𝑑3

π‘‰π‘’π‘™π‘œπ‘π‘–π‘‘π‘¦ π‘”π‘Ÿπ‘Žπ‘‘π‘–π‘’π‘›π‘‘, 𝐺 = βˆšπ‘ƒ

πœ‡ βˆ™ 𝑉1

π‘ƒπ‘œπ‘€π‘’π‘Ÿ π‘Ÿπ‘’π‘žπ‘’π‘–π‘Ÿπ‘’π‘‘, 𝑃 = 𝐺2πœ‡π‘‰1 = 7002 π‘ βˆ’2 Γ— 0.022 𝑙𝑏𝑓 βˆ™ 𝑠

𝑓𝑑2Γ— 202.85 𝑓𝑑3 = 2186723

𝑓𝑑 βˆ™ 𝑙𝑏𝑓

𝑠

= 2.18 Γ— 106 𝑓𝑑 βˆ™ 𝑙𝑏𝑓

𝑠

πΉπ‘™π‘œπ‘€ π‘Ÿπ‘Žπ‘‘π‘’ π‘œπ‘“ 1 π‘π‘Žπ‘ π‘–π‘›, 𝑄1 =𝑉1

𝑑=

202.85 𝑓𝑑3

30 𝑠= 6.76

𝑓𝑑3

𝑠

𝑄 =28.9 Γ— 106π‘”π‘Žπ‘™

1 π‘‘π‘Žπ‘¦Γ—

1 π‘‘π‘Žπ‘¦

24 β„Žπ‘ŸΓ—

1 β„Žπ‘Ÿ

60 π‘šπ‘–π‘›Γ—

1 π‘šπ‘–π‘›

60 𝑠×

0.134 𝑓𝑑3

1 π‘”π‘Žπ‘™= 44.82

𝑓𝑑3

𝑠

π‘π‘’π‘šπ‘π‘’π‘Ÿ π‘œπ‘“ π‘‘π‘Žπ‘›π‘˜π‘  =𝑄

𝑄1

=44.82

6.76= 6.63 β‰ˆ 7 π‘‘π‘Žπ‘›π‘˜π‘ 

π΅π‘Žπ‘“π‘“π‘™π‘’ π‘£π‘œπ‘™π‘’π‘šπ‘’ = β„Ž Γ— π‘π‘Žπ‘“π‘“π‘™π‘’ π‘™π‘’π‘›π‘”π‘‘β„Ž Γ— 𝑀 = 8.38 Γ— 0.492 Γ— 4.92 𝑓𝑑3 = 20.28 𝑓𝑑3

Flocculation:

Equation 1:

βˆ€= 𝑑𝑄 = 36π‘šπ‘–π‘› βˆ— 28.9𝑀𝑔𝑑 = 96,815 ft2

Equation 2: π‘Š =

βˆ€

πΏβ„Ž=

96,815 ft2

36𝑓𝑑 βˆ— 12 𝑓𝑑= 225 𝑓𝑑

Equation 3: 𝐿 = π‘‘π‘‰β„Ž = 36π‘šπ‘–π‘› βˆ— 1

𝑓𝑑𝑠⁄ = 36 𝑓𝑑

Equation 4:

π‘Šπ‘π‘Žπ‘‘π‘‘π‘™π‘’ =πΏπ‘π‘Žπ‘‘π‘‘π‘™π‘’

20=

9.93𝑓𝑑

20= 0.5 𝑓𝑑

Equation 5: 𝑃 = 𝐺2βˆ€πœ‡ = 60 1

𝑠⁄ βˆ— 6,454.3𝑓𝑑2 βˆ— 0.8701𝐸 βˆ’ 3π‘ƒπ‘Ž βˆ— 𝑠 = 0.767β„Žπ‘

Equation 6:

𝑉𝑝 =

√2𝑃

𝐢𝐷 βˆ— 𝐴𝑝 βˆ— 𝜌

3

0.5=

√2 βˆ— 421.85

𝑓𝑑 βˆ— 𝑙𝑏𝑠⁄

1.8 βˆ— 9.93 βˆ— 0.5 βˆ— 1.936𝑠𝑙𝑒𝑔𝑠

𝑓𝑑3⁄

3

0.5= 2.90

𝑓𝑑𝑠⁄

Sedimentation:

Equation 1:

25 | P A G E

𝑑 =𝑉( 24)

𝑄π‘₯ #π‘π‘Žπ‘ π‘–π‘›π‘ 

β†’ π‘₯ =4 β„Žπ‘Ÿ(28.9 βˆ— 106π‘”π‘Žπ‘™)

19200𝑓𝑑3(π‘‘π‘Žπ‘¦)

1π‘‘π‘Žπ‘¦

24β„Žπ‘Ÿ

.133681𝑓𝑑3

1 π‘”π‘Žπ‘™ = 33.54 = 34 π‘π‘Žπ‘ π‘–π‘›π‘ 

Equation 2:

𝑣 =𝑄

𝐴=

28.9 βˆ— 106 π‘”π‘Žπ‘™

160𝑓𝑑2 (π‘‘π‘Žπ‘¦)

.133681 𝑓𝑑3

1 π‘”π‘Žπ‘™

1 π‘‘π‘Žπ‘¦

1440 π‘šπ‘–π‘›

1

34 π‘π‘Žπ‘ π‘–π‘›π‘ = .49318

𝑓𝑑

π‘šπ‘–π‘›

Equation 3:

𝑣 =𝑄

𝐴=

28.9 βˆ— 106 π‘”π‘Žπ‘™

2400 𝑓𝑑2 (π‘‘π‘Žπ‘¦)

1

34 π‘π‘Žπ‘ π‘–π‘›π‘ = 354.167

π‘”π‘Žπ‘™

𝑓𝑑2 (π‘‘π‘Žπ‘¦)

Equation 4:

π‘‡π‘œπ‘‘π‘Žπ‘™ π‘Šπ‘’π‘–π‘Ÿ πΏπ‘’π‘›π‘”π‘‘β„Ž =𝑄

π‘Šπ‘’π‘–π‘Ÿ πΏπ‘œπ‘Žπ‘‘π‘–π‘›π‘”=

28.9 βˆ— 106 π‘”π‘Žπ‘™

20,000 π‘”π‘Žπ‘™

π‘‘π‘Žπ‘¦ βˆ— π‘“π‘‘βˆ— π‘‘π‘Žπ‘¦

1

34 π‘π‘Žπ‘ π‘–π‘›π‘ = 42.5 𝑓𝑑

Equation 5:

πΉπ‘–π‘›π‘”π‘’π‘Ÿ π‘Šπ‘’π‘–π‘Ÿ πΏπ‘’π‘›π‘”π‘‘β„Ž =π‘‡π‘œπ‘‘π‘Žπ‘™ π‘Šπ‘’π‘–π‘Ÿ πΏπ‘’π‘›π‘”π‘‘β„Ž βˆ’ π‘Šπ‘–π‘‘π‘‘β„Ž

π‘π‘’π‘šπ‘π‘’π‘Ÿ π‘œπ‘“ πΉπ‘–π‘›π‘”π‘’π‘Ÿπ‘ =

42.5 𝑓𝑑 βˆ’ 20

2= 11.25 𝑓𝑑

Appendix II – Lab 2 Sample Calculations

Granular Media Filtration:

Equation 1:

28.9 MGD Γ—1 day

24 hrΓ—

1 hr

60 min= 20,069.44 gpm

Equation 2:

20069.4 gpm Γ· 5.97gpm

ft2= 3364ft2 total surface area

Reverse Osmosis (RO) Membrane Filtration:

Equation 1:

20,069.44 total gpm Γ· 960 gpm per RO unit = 21 RO units

26 | P A G E

Disinfection:

Equation 1:

ΞΈ = 30 min

28.9 Γ— 106gal

dayΓ—

1 day

1440 minΓ— 30 min = 602,083

gal

30 min

602,083 gal

30 minΓ—

0.133681 ft3

1 gal= 80487.0575

ft3

30 min

Equation 2:

10 ft (width) Γ— 100 ft (length) Γ— 10 ft (depth) = 10,000 ft3

80487.0575 ft3

30 min10,000 ft3

= 8.0487 tanks

Equation 3:

17 Γ— 7 ft Γ— 0.5 ft Γ— 10 ft = 595 ft3

Equation 4:

10,000 ft3 βˆ’ 595 ft3 = 9405 ft3

80487.057 ft3

9405 ft3= 8.5579 tanks β‰… 9 tanks total

Water Treatment Residuals/Waste Handling:

Equation 1:

π‘‡π‘œπ‘‘π‘Žπ‘™ 𝑠𝑙𝑒𝑑𝑔𝑒 π‘ π‘œπ‘™π‘–π‘‘π‘  (𝑙𝑏

π‘šπ‘–π‘™ π‘”π‘Žπ‘™) = 8.34(0.44 Γ— π‘Žπ‘™π‘’π‘š π‘‘π‘œπ‘ π‘Žπ‘”π‘’ + 0.74 Γ— π‘‘π‘’π‘Ÿπ‘π‘–π‘‘π‘–π‘‘π‘¦)

8.34 (0.44 Γ— 20π‘šπ‘”

𝐿+ 0.74 Γ— 4.3 π‘π‘‡π‘ˆ) = 99.93

𝑙𝑏

π‘šπ‘–π‘™ π‘”π‘Žπ‘™

Equation 2:

15π‘”π‘Žπ‘™

𝑓𝑑2π‘šπ‘–π‘›(3364𝑓𝑑2) = 50,460

π‘”π‘Žπ‘™

π‘šπ‘–π‘›

Equation 3:

12 π‘šπ‘–π‘› (50,460π‘”π‘Žπ‘™

π‘šπ‘–π‘›) = 605,520π‘”π‘Žπ‘™

605,520π‘”π‘Žπ‘™

28.9 Γ— 106galΓ— 100% = 2.1% π‘œπ‘“ π‘‘π‘Žπ‘–π‘™π‘¦ π‘“π‘™π‘œπ‘€

27 | P A G E

Appendix III – Lab 3 Tables and Calculations Time

(h) Flow

(m^3/s) Volume in

(m^3) Volume out

(m^3) Change in storage (in-

out)

0 0.0481 173.16 203.66 -30.50

100 0.0359 129.24 203.66 -74.42

200 0.0226 81.36 203.66 -122.30

300 0.0187 67.32 203.66 -136.34

400 0.0187 67.32 203.66 -136.34

500 0.0198 71.28 203.66 -132.38

600 0.0226 81.36 203.66 -122.30

700 0.0359 129.24 203.66 -74.42

800 0.0509 183.24 203.66 -20.42

900 0.0631 227.16 203.66 23.51

1000 0.067 241.2 203.66 37.55

1100 0.0682 245.52 203.66 41.87

1200 0.0718 258.48 203.66 54.83

1300 0.0744 267.84 203.66 64.19

1400 0.075 270 203.66 66.35

1500 0.0781 281.16 203.66 77.51

1600 0.0806 290.16 203.66 86.51

1700 0.0843 303.48 203.66 99.83

1800 0.0854 307.44 203.66 103.79

1900 0.0806 290.16 203.66 86.51

2000 0.0781 281.16 203.66 77.51

2100 0.067 241.2 203.66 37.55

2200 0.0583 209.88 203.66 6.23

2300 0.0526 189.36 203.66 -14.30

Cumulative Sum

BOD (mg/L)

Mass of BOD in (kg)

Storage average (mg/L)

Mass loading (kg)

-30.50 110.00 19.05 120.45 24.53

-104.91 81.00 10.47 97.61 19.88

-227.21 53.00 4.31 70.18 14.29

-363.54 35.00 2.36 44.85 9.13

-499.88 32.00 2.15 33.50 6.82

-632.25 40.00 2.85 36.11 7.35

-754.55 66.00 5.37 53.86 10.97

-828.96 92.00 11.89 81.96 16.69

-849.38 125.00 22.91 111.35 22.68

-825.87 140.00 31.80 133.30 27.15

-788.33 150.00 36.18 145.15 29.56

28 | P A G E

-746.46 155.00 38.06 152.52 31.06

-691.64 160.00 41.36 157.56 32.09

-627.45 150.00 40.18 154.91 31.55

-561.11 140.00 37.80 144.98 29.53

-483.60 135.00 37.96 137.45 27.99

-397.10 130.00 37.72 132.46 26.98

-297.27 120.00 36.42 124.89 25.43

-193.48 125.00 38.43 122.52 24.95

-106.98 150.00 43.52 137.14 27.93

-29.47 200.00 56.23 174.61 35.56

8.07 215.00 51.86 206.93 42.14

14.30 170.00 35.68 194.06 39.52

0.00 130.00 24.62 151.03 30.76

Total Input (m3): 4887.72

Total Output (m3/h): 203.655

Volume of Basin: = |smallest difference| + largest positive difference

= |-136.335|+103.785

= 240.12 *1.25 (it is multiplied by 1.25 to handle excess capacity)

= 300.15 π‘š3

Figure 3.2 Graph comparing equalized and un-equalized flow

0

10

20

30

40

50

60

0 1000 2000 3000

BO

D L

oa

din

g

Hour of Day

Equalized and Unequalized Flow

Unequalized

Equalized

29 | P A G E

References

Alturkmani, Abdulrzzak. "Environmental Engineering - Equalization." Environmental Engineering.

Dr. Eng Abdulrzzak Alturkmani, 2010. Web. 17 Apr. 2016.

"Biochemical Oxygen Demand." Sustainable Development Knowledge Platform. United Nations,

2015. Web.

"Liquid Wastewater Processing." Chalfont New Britain Twp Sewage Authority. Chalfont New Britain

Twp Sewage Authority, 2013. Web.

β€œDemographics.” Sanford, Florida, the Friendly City. City of Sanford, 2010. Web. 14 Feb 2016.

Droste, Ronald L. Theory and Practice of Water and Wastewater Treatment. New York: J. Wiley, 1997. Print.

Hammer, Mark J., and Mark J. Hammer, Jr. Water and Wastewater Technology. Englewood Cliffs,

NJ: Prentice Hall, 2008. Print.

Lowe, Edgar F. et al. β€œSt. Johns River Water Supply Impact Study.” St. Johns River Water

Management District. St. Johns River Water Management District, 2012. Pdf. 14 Feb. 2016.