Spill Containers
517 Series
3 ½ Gallons AST Spill Container
518 Series
7 ½ Gallon AST Spill Container
515 Series
AST Remote Spill Container
Installed on aboveground storage tanks for the
purpose of containing small spills and drips from the
fill nozzle. 3 ½ gallon capacity. Steel construction.
Lockable and white powder coated. Available in 2”
and 4”.
Installed on aboveground storage tanks for the purpose of
containing small spills and drips from the fill nozzle. 7 ½
gallon capacity. Lockable with drain valve and vented lid.
Connects to 4” male (NPT) riser, and is white powder
coated. Female NPT x Female NPT. Available in 2” and 4”.
For use on aboveground storage tanks for the purpose of
containing fuel spillage during remote tank filling
operations. 15 gallon capacity. 12 gauge steel construction.
Lockable lid, and powder coated white for durability. 1”
NPT drain with locking ball valve included. Choice of one or
two fill ports, 2”, 3”, 4” or combination. 2” bung for pump.
Single column base is easily adjustable.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 2
Emergency Vents
Male Threaded Emergency Vents
Product SKU: 244OM
Female Threaded Emergency Vents
Product SKU: 244O
Flanged Emergency Vents
Product SKU: 244OF
Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement that helps prevent the tanks from becoming over-pressurized and rupturing if exposed to fire. Available in 2”, 3”, 4”, 6”, and 8”.
The 244 emergency vent consists of a body and a black powder coated cover (2" not powder coated) that moves up and down on a center pin. Pressure inside the tank forces the cover to lift up off the vent seat, allowing air to exhaust. The center pin guides the movement. When pressure falls the cover lowers back down onto seat and the vent is automatically reset.
Warning: The 244 emergency vent is for “emergency pressure relief only” and must be used in conjunction with a “normal vent” or pressure vacuum vent such as a Morrison Fig. 354, 548, 748 or 749.
Warning: The 244 emergency vent must be properly sized and selected for each specific tank application in order to meet the proper “venting capacity” requirements. See the Morrison Vent Guide for further instructions.
Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement that helps prevent the tanks from becoming over-pressurized and rupturing if exposed to fire. UL and ULC listed.
The 244 emergency vent consists of a body and a black powder coated cover (2" not powder coated) that moves up and down on a center pin. Pressure inside the tank forces the cover to lift up off the vent seat, allowing air to exhaust. The center pin guides the movement. When pressure falls the cover lowers back down onto seat and the vent is automatically reset.
Warning: The 244 emergency vent is for “emergency pressure relief only” and must be used in conjunction with a “normal vent” or pressure vacuum vent such as a Morrison Fig. 354, 548, 748 or 749.
Warning: The 244 emergency vent must be properly sized and selected for each specific tank application in order to meet the proper “venting
capacity” requirements. See the Morrison Vent Guide for further
instructions.
Emergency vent (pressure relief only) used on aboveground storage tanks, as a code requirement that helps prevent the tanks from becoming over-pressurized and rupturing if exposed to fire. UL and ULC listed.
The 244 emergency vent consists of a body and a black powder coated cover (2" not powder coated) that moves up and down on a center pin. Pressure inside the tank forces the cover to lift up off the vent seat, allowing air to exhaust. The center pin guides the movement. When pressure falls the cover lowers back down onto seat and the vent is automatically reset.
Warning: The 244 emergency vent is for “emergency pressure relief only” and must be used in conjunction with a “normal vent” or pressure vacuum vent.
Warning: The 244 emergency vent must be properly sized and selected for each specific tank application in
order to meet the proper “venting capacity” requirements. See the Morrison Vent Guide for further
instructions.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 3
Atmospheric Vents 354 Series
Updraft Vent
155S Series
Double Outlet Vent
Mushroom Vent Caps
Part Number Female NPT
4021 ¾”
4022 1”
4023 1 ¼”
4024 1 ½”
4025 2”
4027 3”
4028 4”
“Open” vent used on underground and aboveground tanks for motor fueling. Vent allows tank to “breathe” during filling/dispensing operations. Available in 1 ½”-4”. Note: Open vents will allow unrestricted evaporation of product. Construction Details Body: Aluminum Cap: Aluminum Screen: 40 Mesh Brass
Aluminum T-style vent used primarily on small fuel oil storage
tanks. Outlet ports on either side of the inlet with 20 mesh
stainless steel screen keeps debris out of the airway. Available
in ¾”-3”.
This popular style is used in the majority of installations in the United States, Alaska, and Canada . Rust-resistant zinc-plated cast iron design is available in female NPT sizes from 3/4" to 4". Each cap is designed with a 30 mesh screen, to prevent debris from entering the vent pipe.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 4
Fill Caps- Splash Fill
179 Series
179M Hinged Style Fill Cap- Aluminum, Male
178DT Series
Threaded Style Fill Cap- Drop Tube
Loose-seal style cap with hinged cover. For fill port of small
storage tanks. Lockable with a padlock. Aluminum or cast iron.
Also available with male or female threads. Cast iron caps
available painted black. Available 2”.
Tight-seal style threaded cap. For fill port of small storage tanks. Lockable with a padlock. Powder coated black. Body is available in iron (IB) or brass (BB). Cap is available in iron (IC) or brass (BC). Buna-N gasket. Available in 2”-4”.
Made for a drop tube with 2" straight pipe threads and Buna-N gasket.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 5
Fill Caps and Adaptors-Tight Fill
633 AST Series
Tank Inlet Spout Adaptors with Crossbar
1600 Series
Poppeted Kamvalok® Adaptors
Tight fill adaptors for use on remote
aboveground storage tanks. Available in
various materials and various sizes.
Part A
Part F
Fuel Delivery Couplers & Accessories are designed to connect fuel delivery transport truck hoses or nozzles to the fill pipe of an aboveground storage tank. The 633AST Series Adaptors, with a boss installed across the inlet, are designed to prohibit open-fills. Available in 2”.
Fuel Delivery Couplers & Accessories are designed to
connect fuel delivery transport truck hoses or nozzles
to the fill pipe of an aboveground storage tank.
Available in aluminum and stainless steel. Available in
1 ½ “-3”.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 6
Anti-Siphon Devices
Anti-Siphon Valves
Series 600
Solenoid Valve
Model 710
Anti-Siphon Valve with Expansion Relief
EBW’s Anti Siphon Valves are recommended for all above
ground storage applications to prevent fuel from exiting the
storage tank in the event of a broken line or leak. Each valve
has an adjusting mechanism allowing for various liquid head
pressure settings within the valve range. Available in sizes
¾ “-2”.
Installed on pipeline leading from an aboveground tank. This
valve is used to help prevent accidental siphoning of product
from the tank in the event of a fracture in the pipe or other
cause for leak downstream and below the liquid level.
Available in ¾” -3”, Aluminum and stainless steel, and AC or
DC coils.
Anti-Siphon Valve is used on storage tank systems to prevent
the formation of a siphon in the event of a line break or leak. It
will help prevent product loss, environmental contamination
and/or fire hazards. It is available in ¾”-1”.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 7
Overfill Prevention Valves
AST Overfill Prevention Valve
9095A
AST Overfill Prevention Valve
9095C Series
AST Overfill Prevention Valve
9095S Series
Installed at the fill port of an aboveground storage tank.
Used in a tight fill application, the valve terminates flow of
product when the liquid level reaches a preset warning level
(90-95% full). Available in 2” and 3”.
The 9095C Morrison Overfill Prevention Valve is designed
for use on low-profile top-loading aboveground storage
tanks and tanks that require a high level shutoff. The
9095C Overfill Prevention Valve is installed at the fill port
of a tank. Available in 2”.
The ULC listed Morrison Overfill Prevention Valve is
designed for use on low-profile, top-loading storage
tanks that require a high level shutoff. The valve
terminates the fill when the product reaches the
preset level. The valves can be retrofitted on existing
tanks and fits into a 2" opening. Available in 2”.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 8
Overfill Prevention Valves Mechanical Test Mechanism for use with 9095A Series Valves
Overfill Prevention Valve for Used Oil Systems
FMMASO Series
3’ x 4” Overfill Prevention Valve with Audible Alarm
Available in 2” and 3”.
Valve with optional alarm for use on used oil
evacuation systems which use an air operated
pump. Available in 2”.
Combination of #1228 C&B 3X4 Overfill Prevention Valve and #1400 Audible Alarm allows for high level alarm and Overfill Prevention of an AST through one opening. The C&B 3X4 is mechanical in operation and reliably shuts off the fuel supply of an AST at a predetermined level. Alarm is battery operated, intrinsically safe, and complies with NEMA requirements. 95 decibel alarm alerts delivery person when fluid in tank reaches the predetermined level.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 9
Overfill Monitors High Level/Interstitial Alarm
Gallon Gauge Alarm
918C
Provides an audible alarm for either a high or low level warning.
Incorporates an alarm box and a single-point level sensor. Contains
a battery powered, intrinsically safe, alarm unit that is mounted
remote from gauge. The single point level sensor is immersed in
the tank through a 2" NPT Female opening and is supported by a
nylon liquid tight cable connector, Teflon tubing and wire. The high
or low activation point is set at the factory. The order length
should be equal to the distance from the top of the 2" tank
opening to the desired activation level. The low level activation
point can be set up to 113". The interstitial monitor level can be set
up to 113" as well. Available with either 0-53" probe or 53"-113"
probe.
The Morrison Model 918C Gallon Gauge is used to
measure the liquid level in an aboveground storage
tank. The Gallon Gauge provides an approximate read
out clearly displayed in gallons, and can easily be read
from 20 feet away! The Morrison Gallon Gauge
eliminates the need to convert feet and inch gauge
readings to gallons. The 918C includes a high level
audible alarm.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 10
Overfill Monitors OPW 444TA AST Four Signal Tank Alarm and
144TA AST Liquid Level Tank Alarm
High/Low level Audible Fill Alarm
Model ATA-Tank Monitor
The OPW AST remote Four Signal Tank Alarm is designed to sense up to four different liquid levels or other signals using just one device. The OPW 144TA Tank Alarm is designed for liquid level sensing.
Our new Audible Fill Alarm can be retrofitted to all of our
most popular tank gauges. It is cost effective and easy to
maintain. This item can provide High Liquid Level Alarms,
Overfill Tank Alarm, Leak Detection Alarm, Low Level Alarm,
and Interstitial Alarms.
An intrinsically safe tank monitor can be used to monitor
high or low levels and/or leak detection. Available in 115
volt. Meets NEMA 4 requirements. One and two channel
panels available.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 11
Tank Gauging Gallon Gauge
818C
Electronic AST Mechanical Tank Gauge
1018
OPW 200 TG AST Mechanical Tank Gauge
The Morrison Model 818C Gallon Gauge is used to
measure the liquid level in an aboveground storage
tank. The Gallon Gauge provides an approximate read
out clearly displayed in gallons, and can easily be read
from 20 feet away! The Morrison Gallon Gauge
eliminates the need to convert feet and inch gauge
readings to gallons.
Monitors 1 to 4 aboveground storage tanks per console. Each gauge can be located up to 1000 ft. from the console. Can measure tanks up to 35 ft. in height, including vertical or horizontal cylindrical tanks and rectangular tanks. Accurate to 0.1”. Choose Feet-Inches, Inches or Gallons. Metric readout can also be selected as an option on the console.
The OPW 200TG Tank Gauge is designed for reading liquid levels in horizontal or vertical aboveground storage tanks. The 200TG Tank Gauge provides an accurate numerical counter readout, eliminating the need for any on-site manual gauging.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 12
Tank Gauging Type-D At-A-Glance Gauge
Type-K Leak Gauge
Type-O Overfill Alert
The At-A-Glance Type D Liquid Level Gauge is a reliable, swing arm type tank gauge used for measuring all types of liquid levels. This sight gauge’s simple mechanical design promotes durability, minimal upkeep, quick installation, and easy/inexpensive repairs.
This liquid level gauge is custom made in house to fit your tank. We can accommodate any size tank from 6 inches to 12 feet in depth, we can also account for double walls and pipe risers, and we offer multiple materials of construction to accommodate nearly any type of liquid.
The Leak Type K Gauge is a reliable, vertical type leak monitor used for detecting leaks in the annular/interstitial space of a double wall above ground containment tank (AST's). Its simple mechanical design promotes durability, minimal upkeep, quick installation, and easy/inexpensive repairs.
This Interstitial Leak Gauge is custom made in house to fit your tank. We can accommodate any size tank from 6 inches to 170 inches in depth.
The Overfill Alert Gauge is a high level visual gauge designed to visually alert you that your AST (tank) is near full. This overfill monitor's simple pop up mechanical design promotes easy installs, maximum durability, and low up-front costs.
Also, by purchasing our Overfill Alarm Accessory, you can turn your visual overfill gauge into an audible overfill alarm.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 13
Tank Gauging
Black Night
Red Fox
Jarhead
Numbers decrease as fluid level lowers indicating how many inches are left until the tank is empty. For use with oil, waste oil, diesel fuel, antifreeze, water and other fluids with a low flash point. Measures from 99”-0”. Available in 2” N.P.T. threads.
Numbers decrease as fluid level rises indicating how many inches are left until the tank is full. For use with oil, waste oil, diesel fuel, antifreeze, water and other fluids with a low flash point. Measures from 99”-0”. Available in 2 inch N.P.T. threads.
For use with oil, waste oil, diesel fuel, antifreeze, water
and other fluids with a low flash point. Available in 1 ½ “-2”
N.P.T threads.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 14
Emergency Valves 272 Series Internal Emergency Valve
External Emergency Valve-Ductile Iron
346 Series
Fire Safety Valves
12000 Series
Used to shut off flow in the event of fire. Fusible link holds
open spring actuated lever. Body mounts at the base of an
aboveground tank with plunger end projecting inside the
tank. Available in Brass and Ductile Iron. Available in 2”, 2 ½”,
3”, and 4” threaded and flanged.
Used to shut off flow in the event of fire. Fusible
link holds open spring actuated lever. Mounts on
external pipeline. Available in 1 ½”, 2”, and 3”.
Fusible Fire Safety Valves are designed to reduce fire
damage by shutting off the flow of oil from the oil tank in
the event of a fire. These valves conform to UL/ULC 842
and are listed in the US and Canada. They are required by
code in residential oil heating installations in conformance
with NFPA 31. Available in 3/8”-1”. FM NPT and Flare.
Available in brass construction.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 15
Emergency Valves Farm Tank Emergency Valve- Angle Type
474 Series
Farm Tank Emergency Valve-Straight Type
574 Series
Quick Opening Gate Valve with External Spring
238 Series
Emergency shutoff in case of fire. Male thread to
tank with plunger inside tank. Angled body to
female threaded outlet. Fusible link holds plunger
open. 5 PSI Maximum. Available 1” x ¾” and
1” x 1”.
Emergency shutoff closes in case of fire. Male
thread to tank with plunger inside tank. Straight
body with male threaded outlet. Fusible link holds
plunger open. 5 PSI Maximum. Available 1” x 1”.
Quick opening gate valves are manually-operated double disc gate valves designed for use where simple lever action opens or closes the valve. The 238 Series has an external spring and will remain closed when not held open. Can be held open with fusible link device. Available in 1 ¼” -3”. Available in brass construction.
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 16
Pumps and Meters
For more information see section: Fuel Pumps and Accessories
T o m l i n C o r p o r a t i o n P h . 2 1 6 - 6 4 1 - 1 8 0 0 F a x . 2 1 6 - 6 4 1 - 5 2 5 0
Page 17
Decals and Placards
Many options available with specific wording and sizes
Please ask us about custom decals
Fuel Identification labels with numerous wording options in stock
Available in different color combinations
Available in 3” x 12”, or 4” x 13 ½”
Diamond placards are available with a variety of preprinted UN numbers
Available as a decal, metal sign, or rigid vinyl material
Two-sided rigid vinyl preprinted placards available
NFPA signs are available in several sizes
Vinyl decals, magnetic or aluminum material
Meets NFPA 704 requirements
Pre-numbered decals are offered for your convenience