50
894 Networking:Wall-MountCabinets Wall-MountCabinetsProductSelectionGuide PH(763)422-2661•FX(763)422-2588•hoffmanonline.com Subjecttochangewithoutnotice ©2011PentairTechnicalProducts Wall-Mount Cabinets Wall-Mount Cabinets Product Selection Guide Wall-MountCabinetsProductSelectionGuide WALL-MOUNT FAMILY ACCESSPLUS ® II PROTEK ® PROTEK ® DOUBLE-HINGED Description ACCESSPLUS ® II Double-Hinged Wall- Mount provides both security and acces- sibility. Designed to hold multiple pieces of voice data equipment. Perfect where space is at a premium. • Double–hinged wall mount PROTEK ® Wall-Mount Cabinets are ideal for protecting network equipment beyond typical Type 1 enclosures. • Harsh environments • Models with A/C units Offers the flexibility and accessibility of a double-hinged wall-mount and the envi- ronmental protection of the PROTEK Type 4/12 ratings. • Double-hinged wall-mount • Harsh environments • Models with A/C units Construction Mild steel Mild steel Mild steel Application Rating Indoors with built-in ventilation areas Indoors and outdoors. Protects from dust, dirt and splashing water. Protects from dust, dirt and splashing water. DIMENSIONS Rack Units (RU) Range 12–39 RUs 12–26 RUs 7–26 RUs Height 25.00–72.00 in. 24.00–48.00 in. 16.00–48.00 in. Width 24.00 in., 28.00 in. 24.00 in. 24.00 in. Depth 18.00–25.00 in. 12.00–24.00 in. 15.00–25.00 in. RATINGS Loading - Static 250–500 lbs. 100–200 lbs. 100–175 lbs. Certifications and Listings UL 508A, CSA, NEMA, IEC UL 508A, CSA, NEMA, IEC UL 508A, CSA, NEMA, IEC Type / NEMA / IP Rating Type 1, IP40 Type 1, 4, 12, IP55/IP66 Type 1, 4, 12, IP55/IP66 Plenum Rated Yes Yes Yes STRUCTURE Front Door Window or solid Window or solid Window or solid Back Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out Rear mounting studs, panel-ready and wall-mounting provisions Rear mounting studs, panel-ready and wall-mounting provisions Top / Bottom Gland Plate/Cable knock-outs, fan-ready Solid sheet steel construction Solid sheet steel construction Sides Cable knock-outs, fan-ready Solid sheet steel construction Solid sheet steel construction Rack Angles 1 set tapped 10-32 fully adjustable, plated 1 set tapped 10-32 fully adjustable, plated 1 set tapped 10-32 fully adjustable, plated APPLICATIONS Most frequently utilized model for mount- ing network equipment. Gland-plate offer- ing great for retrofit applications. Ideal for remote areas with harsh environ- ments for network equipment. Extra-deep to accommodate rack equipment. Ideal for remote areas with harsh environ- ments for network equipment. Extra-deep to accommodate rack equipment. Unique Features • Single person mounting • Latch-free sides permit flush-mounting to adjacent equipment, enclosures and walls • Safety glass window units • Pole mounting kit available • Reversible hinges (left/right) • Grounding and bonding provisions • Available with T4 A/C units • Extra-deep sizes • Fully vented with foam-in-place gasket • Safety Glass • Rack angle standard • Grounding and bonding provisions • Available with T4 A/C units • Extra deep sizes • Fully vented with foam-in-place gasket • Safety Glass • Rack Angle Standard • Front and Rear Access • Grounding and bonding provisions

Upload: dinhdat

Post on 08-Dec-2016

224 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

894

Networking:Wall-MountCabinets

Wall-MountCabinetsProductSelectionGuide

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Wall-Mount CabinetsWall-Mount Cabinets Product Selection Guide

Wall-MountCabinetsProductSelectionGuide

1Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • hoffmanonline.com © 2009 Hoffman Enclosures Inc.

Networking: Wall-Mount Cabinets

Wall-Mount Cabinets Product Selection Guide

Spec-00449 C

Wall-Mount Cabinets Product Selection Guide

Wall-Mount FaMily ACCESSPLUS® II PROTEK® PROTEK® DOUBLE-HINGED

Description ACCESSPLUS® II Double-Hinged Wall-Mount provides both security and acces-sibility. Designed to hold multiple pieces of voice data equipment. Perfect where space is at a premium.

• Double–hinged wall mount

PROTEK® Wall-Mount Cabinets are ideal for protecting network equipment beyond typical Type 1 enclosures.

• Harsh environments• Models with A/C units

Offers the flexibility and accessibility of a double-hinged wall-mount and the envi-ronmental protection of the PROTEK Type 4/12 ratings.

• Double-hinged wall-mount • Harsh environments • Models with A/C units

Construction Mild steel Mild steel Mild steel

Application Rating Indoors with built-in ventilation areas Indoors and outdoors. Protects from dust, dirt and splashing water.

Protects from dust, dirt and splashing water.

DiMensionsRack Units (RU) Range 12–39 RUs 12–26 RUs 7–26 RUs

Height 25.00–72.00 in. 24.00–48.00 in. 16.00–48.00 in.

Width 24.00 in., 28.00 in. 24.00 in. 24.00 in.

Depth 18.00–25.00 in. 12.00–24.00 in. 15.00–25.00 in.

RatingsLoading - Static 250–500 lbs. 100–200 lbs. 100–175 lbs.

Certifications and Listings UL 508A, CSA, NEMA, IEC UL 508A, CSA, NEMA, IEC UL 508A, CSA, NEMA, IEC

Type / NEMA / IP Rating Type 1, IP40 Type 1, 4, 12, IP55/IP66 Type 1, 4, 12, IP55/IP66

Plenum Rated Yes Yes Yes

stRuctuReFront Door Window or solid Window or solid Window or solid

Back Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out

Rear mounting studs, panel-ready and wall-mounting provisions

Rear mounting studs, panel-ready and wall-mounting provisions

Top / Bottom Gland Plate/Cable knock-outs, fan-ready Solid sheet steel construction Solid sheet steel construction

Sides Cable knock-outs, fan-ready Solid sheet steel construction Solid sheet steel construction

Rack Angles 1 set tapped 10-32 fully adjustable, plated 1 set tapped 10-32 fully adjustable, plated 1 set tapped 10-32 fully adjustable, plated

applicationsMost frequently utilized model for mount-ing network equipment. Gland-plate offer-ing great for retrofit applications.

Ideal for remote areas with harsh environ-ments for network equipment. Extra-deep to accommodate rack equipment.

Ideal for remote areas with harsh environ-ments for network equipment. Extra-deep to accommodate rack equipment.

Unique Features • Single person mounting• Latch-free sides permit flush-mounting to

adjacent equipment, enclosures and walls• Safety glass window units• Pole mounting kit available• Reversible hinges (left/right)• Grounding and bonding provisions

• Available with T4 A/C units • Extra-deep sizes • Fully vented with foam-in-place gasket • Safety Glass • Rack angle standard • Grounding and bonding provisions

• Available with T4 A/C units • Extra deep sizes • Fully vented with foam-in-place gasket • Safety Glass • Rack Angle Standard • Front and Rear Access • Grounding and bonding provisions

Spec-00449.indd 1 10/07/09 9:48:09 AM

Page 2: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

895

Networking:Wall-MountCabinets

Wall-MountCabinetsProductSelectionGuide

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts2 Subject to change without notice PH 763 422 2211 • FX 763 422 2600 • hoffmanonline.com © 2009 Hoffman Enclosures Inc.

Networking: Wall-Mount Cabinets

Wall-Mount Cabinets Product Selection Guide

Spec-00449 C

L-BOX® D-BOX™ WIFI ENCLOSURE—2 MODELS COMLINE®

L-BOX® provides convenient mounting and storage for patch panels in a space-saving design.

• Horizontal cable distribution• Copper to fiber• Consolidation points• Vertical rack angles

D-BOX™ provides convenient mounting and storage for patch panels.

• Horizontal cable distribution• Copper to fiber• Consolidation points• Fixed and rotating rack angles

Provides a secure enclosure for WiFi and other network equipment. Fiberglass does not impede WiFi/WLAN signals.

• Corrosion resistant • Plenum rated • Plywood back panel provided

Lightweight, corrosion-resistant aluminum enclosure provides long-lasting protection for electrical and network components for both indoor and outdoor environments.

• Corrosion-resistant• Outdoor applications (OSP)

Mild steel Mild steel Fiberglass Aluminum

Indoors with built-in ventilation areas. Indoors with built-in ventilation areas. Indoors and outdoors plus hazardous areas. Protects from dust, dirt and splash-ing water.

Indoors and outdoors plus hazardous areas. Protects from dust, dirt and splash-ing water.

6–12 RUs 4–6 RUs Not applicable for smaller model.Optional RU for large model.

Not supplied as standard.Optional 12–26 RUs

24.00–48.00 in. 24.00–48.00 in. 6.00–24.61 in. 11.80–59.10 in.

24.00 in. 24.00 in. 6.00–24.11 in. 11.80–35.40 in.

12.34 in. 8.34–12.34 in. 4.00–12.64 in. 5.90–11.80 in.

75 lbs. 100 lbs. 50–200 lbs. 50–200 lbs.

UL 1863/508A/60905, CSA NEMA, IEC, EIA 310-D

UL 1863/508A/60905, CSA, NEMA, IEC, EIA 310-D

UL 508A, CSA,NEMA, IEC UL 508A, CSA, NEMA, IEC

Type 1, IP40 Type 1, IP40 Type 4, 4X, 12, 13 IP66 Type 3, 3R, 4, 4X, 12, IP66

Yes Yes Yes—Solid door only Not applicable

Vented wrap-around door Solid with vents Solid or window Solid

Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out

Keyhole mounting slots, accessory raised pads, cable tie-down points, large cable knock-out

Wood panel standard Rear mounting studs, panel-ready and wall-mounting provisions

Cable knock-outs, fan-ready Cable knock-outs, fan-ready Solid fiberglass construction Solid aluminum construction

Cable knock-outs, fan-ready Cable knock-outs, fan-ready Solid fiberglass construction Solid aluminum construction

1 set tapped 10-32, plated • 1 set fixed tapped 10-32, plated • 1 set tapped 10-32, fully adjustable

Optional on largest size • Optional based on size• 1 set tapped 10-32, fully adjustable

Vertical equipment mounting provides horizontal cable distribution. Offers a lower-profile installation.

Fixed and rotating rack angles for easy equipment mounting. Offers a lower-profile installation.

Indoors and outdoors: Great for tunnels, marinas, outside walls and rooftops. Ideal for wireless applications; signals pass unimpeded through fiberglass.

Indoors and outdoors: Great for roof-top, pole mount and tower mounting. Lightweight with corrosion resistance.

• Removable door• Quarter-turn latches with keyed lock• Cable tie-down points• Mounting screws provided• Top and bottom knockouts• Cable spool mounting• Complete accessories—fans, shelves and others• Grounding and bonding provisions

• Removable and reversible door• Quarter-turn latches with keyed lock• Cable tie-down points• Mounting screws provided• Grounding and bonding provisions• Top and bottom knockouts• Cable spool mounting• Complete accessories—fans, shelves and others

• Fiberglass is easily punched or drilled• Foam-in-place gasketing• Removable door with stainless steel hinge pins• Window models are scratch-resistant GE Lexan Margard• Small model—screw cover• Large model—key lock knob

• Solar shield provides cooler interior for outdoor applications

• Foam-in-place gasketing• Latching—one- and three-point options• Door stop• Door options—removable and heavy-

duty continuous• Grounding and bonding provisions

Spec-00449.indd 2 10/07/09 9:48:11 AM

Page 3: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

896

Networking:Wall-MountCabinets

ACCESSPLUS®IIDouble-Hinge

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

ACCESSPLUS® II Double-Hinge

ACCESSPLUS®IIDouble-Hinge,Type1

IndustryStandards

UL508A;Type1;FileNo.E61997cULListedperCSAC22.2No.182.4;FileNo.E230874

EIA310-DNEMA/EEMACType1EIC60529IP20PerBICSITDMMTenthedition,Chapter7,TelecommunicationEnclosures(TE)

ApplicationACCESSPLUS®IICabinetsprovidesecurity,equipmentaccess,coolingandsupportfornetworkandother19-in.rack-mountequipment.Thecabinethasthreecomponents:frontdoor,centersectionandwallsection.

Features• Double-hingedforeasyequipmentaccess;centersectionprovides

19-in.rackmountingperEIAuniversalspacingandisaccessedthroughthefrontdoororswingthecentersectionawayfromthewallsectionforrearaccess

• Roundcorners;nosharpedges• Frontdoorhaseitherasolidsteelorhardened,tintedsafety-glass

windowdoorforsuperiorscratchresistance• Centersectioneasilyremovedfromrearsection;tool-lessone-

personinstallationpossible• Self-grounding,platedsteelrackanglesfullyadjustablewithin

centersection• Wallsectionprovidescableentryandcablemanagementwith

knockoutsorglandplates• Glandplatemodelprovideseasyretrofitandfastinstallationand

allowsforpre-terminatedcablesorpre-wiredpatchpanels;noneedtore-terminateandtest

• Self-lockingcenter-to-wallsectionlatchesintwolocations• Frontaccesstoalllatches(noexposedsidelatches);cabinetcanbe

installedtightlyincorners• Ventedsidesprovidecrossflowventilationtoimproveheat

dissipation• Verticalcablemanagerincludedin28-in.-widemodels• Afulllineofaccessoriesisavailable

SpecificationsFrontDoor(windoworsolidsteel)• Compositeframe(injectionmoldedtopandbottomwithextruded

compositesides)• 140-degreeopeningdoor• Field-reversible(leftorright)hinge• Quarter-turnkeylock,twokeysincluded• Windowdoorisscratch-resistant1/4-in.tintedsafetyglass• Soliddoorhas16gaugesteelinsertwithmatchingblackfinish

CenterSection• Welded14gaugesteel• Solidtopofcentersectionsprovidesprotectionagainstfalling

debris• Ventilatedsides(towhichfanscanbeadded)• Self-latchingclosureconnectscentersectiontowallsection• Self-alignmentrampsupportscentersectiontowallsection• Heavydutycenter-to-rearsectionhingewithquick-releaseself-

retainedhingepineaseswallinstallationRack-MountingAngles• 12gauge,platedsteel• EIAuniversalspaced19-in.rack-mountingholes• RUmarkedfrombottomtotop• Tapped10-32holes,20mountingscrewsincluded

RearWallSection• Welded14gaugesteel• Radiuscorners;nosharpedges• Availablewithknockoutsorglandplates• Raisedpadsforaccessorymounting• Cabletie-downpointsforcablemanagement• Keyholemountingholesallowwallsectiontobemountedover

fastenersandeasesinstallation• Threecable-entrygrommets

FinishPretreatedsteelcoatedwithRAL9005blacklight-textured,low-glosspolyesterpowderpaint.Otherfinishesavailable—contactHoffmanCustomerService.Bulletin:DWDH1

Page 4: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

897

Networking:Wall-MountCabinets

ACCESSPLUS®IIDouble-Hinge

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct WindowDoorCatalogNumber AxBxCin. AxBxCmm RackUnits AdditionalRackAngles(S=SquareHole)(T=TappedHole)EWMW242418 23.60 x 23.62 x 18.20 600 x 600 x 462 12 EWMR24T or EWMR24SEWMW362418 36.02 x 23.62 x 18.20 915 x 600 x 462 19 EWMR36T or EWMR36SEWMW482418 48.03 x 23.62 x 18.20 1220 x 600 x 462 26 EWMR48T or EWMR48SEWMW602418 60.04 x 23.62 x 18.20 1525 x 600 x 462 32 EWMR60T or EWMR60SEWMW722418 72.05 x 23.62 x 18.20 1830 x 600 x 462 39 EWMR72T or EWMR72SEWMW242425 23.62 x 23.62 x 25.09 600 x 600 x 637 12 EWMR24T or EWMR24SEWMW362425 36.02 x 23.62 x 25.09 915 x 600 x 637 19 EWMR36T or EWMR36SEWMW482425 48.03 x 23.62 x 25.09 1220 x 600 x 637 26 EWMR48T or EWMR48SEWMW602425 60.04 x 23.62 x 25.09 1525 x 600 x 637 32 EWMR60T or EWMR60SEWMW722425 72.05 x 23.62 x 25.09 1830 x 600 x 637 39 EWMR72T or EWMR72SEWMW242430 23.62 x 23.62 x 30.01 600 x 600 x 762 12 EWMR24T or EWMR24SEWMW362430 36.02 x 23.62 x 30.01 915 x 600 x 762 19 EWMR36T or EWMR36SEWMW482430 48.03 x 23.62 x 30.01 1220 x 600 x 762 26 EWMR48T or EWMR48S

B dimension does not include wall-to-center section hinge.

Page 5: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

898

Networking:Wall-MountCabinets

ACCESSPLUS®IIDouble-Hinge

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct SolidDoorCatalogNumber AxBxCin. AxBxCmm RackUnits AdditionalRackAngles(S=SquareHole)(T=TappedHole)EWMS242418 23.62 x 23.62 x 18.20 600 x 600 x 462 12 EWMR24T or EWMR24SEWMS362418 36.02 x 23.62 x 18.20 915 x 600 x 462 19 EWMR36T or EWMR36SEWMS482418 48.03 x 23.62 x 18.20 1220 x 600 x 462 26 EWMR48T or EWMR48SEWMS242425 23.62 x 23.62 x 25.09 600 x 600 x 637 12 EWMR24T or EWMR24SEWMS362425 36.02 x 23.62 x 25.09 915 x 600 x 637 19 EWMR36T or EWMR36SEWMS482425 48.03 x 23.62 x 25.09 1220 x 600 x 637 26 EWMR48T or EWMR48S

B dimension does not include wall-to-center section hinge.

StandardProduct WindowDoorwithCableManagerCatalogNumber AxBxCin. AxBxCmm RackUnits AdditionalRackAngles(S=SquareHole)(T=TappedHole) VerticalCableMgr.CatalogNumbera

EWMW242825 23.62 x 27.56 x 25.09 600 x 700 x 637 12 EWMR24T or EWMR24S EWMC24EWMW362825 36.02 x 27.56 x 25.09 915 x 700 x 637 19 EWMR36T or EWMR36S EWMC36EWMW482825 48.03 x 27.56 x 25.09 1220 x 700 x 637 26 EWMR48T or EWMR48S EWMC48

B dimension does not include wall-to-center section hinge.a For additional rack angles, also order vertical cable manager.

Page 6: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

899

Networking:Wall-MountCabinets

ACCESSPLUS®IIDouble-Hinge

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct WindowDoorwithGlandPlateCatalogNumber AxBxCin. AxBxCmm RackUnits AdditionalRackAngles(S=SquareHole)(T=TappedHole)EWMWG242418 23.62 x 23.62 x 18.20 600 x 600 x 462 12 EWMR24T or EWMR24SEWMWG362418 36.02 x 23.62 x 18.20 915 x 600 x 462 19 EWMR36T or EWMR36SEWMWG482418 48.03 x 23.62 x 18.20 1220 x 600 x 462 26 EWMR48T or EWMR48SEWMWG242425 23.62 x 23.62 x 25.09 600 x 600 x 637 12 EWMR24T or EWMR24SEWMWG362425 36.02 x 23.62 x 25.09 915 x 600 x 637 19 EWMR36T or EWMR36SEWMWG482425 48.03 x 23.62 x 25.09 1220 x 600 x 637 26 EWMR48T or EWMR48S

B dimension does not include wall-to-center section hinge.

LoadRating Height LoadCapacity24 in. 250 lb.36 in. 300 lb.48 in. 350 lb.60 in. 400 lb.72 in. 500 lb.

Page 7: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

900

Networking:Wall-MountCabinets

ACCESSPLUS®IIDouble-Hinge

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

VerticalCableManagersfor28-in.-WideCabinet

UseACCESSPLUSCableManagerswhenorderingadditionalrackanglesfor28-in.-widecabinet.Bulletin:DWDH1

CatalogNumber Description FitsCabinetEWMC24 ACCESSPLUS Vertical Cable Manager 24.00 in. A = 24.00; B = 28.00EWMC36 ACCESSPLUS Vertical Cable Manager 36.00 in. A = 36.00; B = 28.00EWMC48 ACCESSPLUS Vertical Cable Manager 48.00 in. A = 48.00; B = 28.00

VerticalCableManagerCapacity Numberofcablesat60percentfilled

CrossSection(Area) 5e(0.22in.dia.) 6(0.28in.dia.) 6A(0.35in.dia.)24.5 in.2 380 300 208

RackAngles Bulletin:DWDH1

CatalogNumber Description RackUnits FitsCabinetEWMR24T Fits 24-in. tapped 12 A = 24.00EWMR36T Fits 36-in. tapped 19 A = 36.00EWMR48T Fits 48-in. tapped 26 A = 48.00EWMR60T Fits 60-in. tapped 32 A = 60.00EWMR72T Fits 72-in. tapped 39 A = 72.00EWMR24S Fits 24-in. square 12 A = 24.00EWMR36S Fits 36-in. square 19 A = 36.00EWMR48S Fits 48-in. square 26 A = 48.00EWMR60S Fits 60-in. square 32 A = 60.00EWMR72S Fits 72-in. square 39 A = 72.00

FanKits Bulletin:DWDH1

CatalogNumber Description FitsCabinetEWMF1 4-in. fan with plug and blocking plates,

115 VAC, 100 CFM smallFits all C = 18.00

EWMF2 4-in. fan with plug and blocking plates,115 VAC, 100 CFM, large

Fits all C = 25.00 or 30.00

Page 8: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

901

Networking:Wall-MountCabinets

ACCESSPLUS®IIDouble-Hinge

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

DataComWall-MountCabinetwithGlandPlateApplication

1

Networking: Wall-Mount Cabinets

ACCESSPLUS® II Double-Hinged

Spec-00554 D

Subject to change without notice PH 763 422 2661 • FX 763 422 2588 • hoffmanonline.com © 2010 Hoffman Enclosures Inc.

DataCom Wall-Mount Cabinet with Gland Plate Application

This cabinet offers significant advantages in retrofit applications. The gland plate is mounted at the top and the bottom to accommodate cable runs from above, below or both. The gland plate casing can be removed while patch panels and associated wiring are brought to the cabinet.

2. Install the cable gland plate onto the wall section.

4. Install the center section, then mount patch panels on rack angles.

5. Close and lock the door.

1. Once the wall section is installed on the wall, lay in the patch panel.

3. Use wire ties or cable wraps to secure the cable to the cabinet.

Spec-00554.indd 1 10/18/2010 1:19:45 PM

Page 9: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

902

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK® Wall-Mount and Double-Hinge Cabinets

PROTEK®,Single-DoorULandNEMAType4or12

IndustryStandards

UL508AListed;Type4or12;FileNumberE619967cULListedperCSAC22.2No.94;Type4or12;FileNumberE61997

NEMA/EEMACType4or12IEC60529,IP66orIP55

ApplicationPROTEK®Cabinetsareanexcellent,off-the-shelfchoiceformounting19-in.racknetworkequipmentinwetordirtyenvironmentswherefloorspaceisatapremium.Solidorsafetyglasswindowdoormodelsprovideapplicationflexibility.

Features• Soliddoorprovidescompletephysicalandvisualprotection• Windowdoor,madewithscratch-resistantsafetyglass,provides

equipmentmonitoringwithoutopeningthedoortominimizecontamination

• Fullyweldedandgroundbodyanddoorconstructionforlong-termgoodappearanceanddurability

• Foam-in-placeseamlessgasketarounddoorsealsagainstoutdoorairinfiltration;isnon-absorbingandchemicalresistant

• Type12cabinetshavesolidorwindowdoorsandalockingwingknobwithtwokeys.Theyprovidesecurityandconvenienceinindoorapplications.

• Type4cabinetshavesoliddoorsandapadlock-capablequarter-turnlatch.Theyprovideeasyoperationandlockingoptionsinindoorandoutdoorapplications.

• Onesetofadjustable,tappedrackanglesincluded• Optionalsquare-hole(.375in.)rackanglesavailableforequipment

mountingflexibility• Rackanglesareplatedandself-groundingfordurabilityandsafety• Collarstudsprovidedonbackofcabinetformountingaccessory

panels• Accessorypanelsformountingadditionalaccessoriesattheback

ofthecabinetincludetie-downpointsandpre-drilledholes• Plenumratedforuseinairexchangeareas

Specifications• Doorsandbodymadeof14gaugesteel• Convenientstudsprovidedonbothdoorandbodyforbonding

andgrounding• Rackanglestapped10-32perEIAstandards;madeof12gauge

self-groundingplatedsteel• Windowisclear,.25-in.thick,scratch-andimpact-resistantsafety

glass• Optionalpolycarbonatewindow(notplenumrated)canbefield-

orfactory-installed.ContactHoffmanCustomerServiceforfactoryinstallation.

• Twenty10-32screwsincluded

FinishPretreatedsteelcoatedwithRAL7035light-grayorRAL9005blacktextured,low-glosspolyesterpowderpaint.Otherfinishesavailable—contactHoffmanCustomerService.Bulletin:DWS12

StandardProduct WindowDoor,NEMA12,IP55

CatalogNumber AxBxCin./mm FinishRackUnits

StandardPanel

AccessoryPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDW242412B 24.00 x 24.00 x 12.00 610 x 610 x 305

Black 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDW242412G 24.00 x 24.00 x 12.00 610 x 610 x 305

Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDW362412B 36.50 x 24.00 x 12.00 927 x 610 x 305

Black 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDW362412G 36.50 x 24.00 x 12.00 927 x 610 x 305

Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDW482412B 48.50 x 24.00 x 12.00 1232 x 610 x 305

Black 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDW482412G 48.50 x 24.00 x 12.00 1232 x 610 x 305

Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDW242424B 24.00 x 24.00 x 24.00 610 x 610 x 610

Black 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDW242424G 24.00 x 24.00 x 24.00 610 x 610 x 610

Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDW362424B 36.50 x 24.00 x 24.00 927 x 610 x 610

Black 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDW362424G 36.50 x 24.00 x 24.00 927 x 610 x 610

Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDW482424B 48.50 x 24.00 x 24.00 1232 x 610 x 610

Black 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDW482424G 48.50 x 24.00 x 24.00 1232 x 610 x 610

Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

Page 10: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

903

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct SolidDoor,NEMA4,IP66

CatalogNumber AxBxCin./mm FinishRackUnits

StandardPanel

AccessoryPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDS242412G4 24.00 x 24.00 x 12.00 610 x 610 x 305

Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDS362412G4 36.50 x 24.00 x 12.00 927 x 610 x 305

Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDS482412G4 48.50 x 24.00 x 12.00 1232 x 610 x 305

Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDS242424G4 24.00 x 24.00 x 24.00 610 x 610 x 610

Gray 12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDS362424G4 36.50 x 24.00 x 24.00 927 x 610 x 610

Gray 19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDS482424G4 48.50 x 24.00 x 24.00 1232 x 610 x 610

Gray 26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

StandardProduct SolidDoor,NEMA12,IP55

CatalogNumber AxBxCin./mmRackUnits

StandardPanel

AccessoryPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDS242412B 24.00 x 24.00 x 12.00 610 x 610 x 305

12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDS242412G 24.00 x 24.00 x 12.00 610 x 610 x 305

12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDS362412B 36.50 x 24.00 x 12.00 92700 x 610 x 305

19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDS362412G 36.50 x 24.00 x 12.00 927 x 610 x 305

19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDS482412B 48.50 x 24.00 x 12.00 1232 x 610 x 305

26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDS482412G 48.50 x 24.00 x 12.00 1232 x 610 x 305

26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDS242424B 24.00 x 24.00 x 24.00 610 x 610 x 610

12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDS242424G 24.00 x 24.00 x 24.00 610 x 610 x 610

12 CP2424 PTP2424A PTRA1924TPL PTRA1924THL

PTDS362424B 36.50 x 24.00 x 24.00 927 x 610 x 610

19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDS362424G 36.50 x 24.00 x 24.00 927 x 610 x 610

19 CP3624 PTP3624A PTRA1936TPL PTRA1936THL

PTDS482424B 48.50 x 24.00 x 24.00 1232 x 610 x 610

26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

PTDS482424G 48.50 x 24.00 x 24.00 1232 x 610 x 610

26 CP4824 PTP4824A PTRA1948TPL PTRA1948THL

Page 11: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

904

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK®Single-DoorFanandFilterThermalPackages,ULandNEMAType1

IndustryStandards

UL508AListed;Type1;FileNumberE619967cULListedperCSAC22.2No.94;Type1;FileNumberE61997

NEMA/EEMAC:Type1IEC60529,IP30

ApplicationPROTEK®FanandFilterPackagesareidealforprotectingsensitive19-in.rackequipmentfromharmfulenvironmentalcontaminantssuchasfallingdirt,dustanddrippingwater.Usewheretheambientaircanbeusedtocooltheinternalequipmentandwhereprotectionfromfallingdirtanddrippingwaterisneeded.Filtersassistinremovingcontaminantsandareeasilyremovedforperiodiccleaningwithoutaccessingthecabinet.Top-mountedfansprovideincreasedairflowandmaximizeheatdissipationofinternallymountedequipment.Bothtop-mountedfansandbottom-mountedintakefiltersarepositionedawayfrom19-in.rack-mountingareas.

Features• Soliddoorprovidescompletephysicalandvisualprotection• Windowdoor,madewithscratch-resistantsafetyglass,provides

equipmentmonitoringwithoutopeningthedoortominimizecontamination

• Fullyweldedandgroundbodyanddoorconstructionforlong-termgoodappearanceanddurability

• Foam-in-placeseamlessgasketarounddoorsealsagainstoutdoorairinfiltration;isnon-absorbingandchemicallyresistant

• Type12cabinetshavewindowdoorsandalockingwingknobwithtwokeys.Theyprovidesecurityandconvenienceinindoorapplications.

• Type4cabinetshavesoliddoorsandapadlock-capable,tamper-resistant,quarter-turnlatch(toolincluded).Theyprovideeasyoperationandlockingoptionsinindoorandoutdoorapplications.

• Onesetofadjustabletappedrackanglesincluded• Optionalsquare-hole(.375-in.)rackanglesavailableforequipment

mountingflexibility• Rackanglesareplatedandself-groundingfordurabilityandsafety• Collarstudsprovidedonbackofcabinetformountingaccessory

panels• Accessorypanelsformountingadditionalaccessoriesattheback

ofthecabinetincludetie-downpointsandpre-drilledholes• Plenumratedforuseinairexchangeareas

Specifications• Doorsmadeof16gaugesteel;bodymadeof14gaugesteel• Convenientstudsprovidedonbothdoorandbodyforbonding

andgrounding• Rackanglestapped10-32perEIAstandards;madeof12gauge

self-groundingplatedsteel• Windowisclear,.25-in.thick,scratch-andimpact-resistantsafety

glass• Optionalpolycarbonatewindow(notplenumrated)canbefield-

orfactory-installed.ContactHoffmanCustomerServiceforfactoryinstallation.

• Twenty10-32screwsincluded• Pagodatop-mounted6-in.fanandbottom-mounted10-in.filter

inlet• Topshroudprotectscabinetandfanfromfallingdebrisand

drippingwater• Bottom-mountedairinletwithoutsideremovableandcleanable

filter• Regularfiltercleaningrequiredforoptimumthermalperformance• Operateson110/115VAC50/60Hzlinevoltage• StandardNEMA15Apluginternaltothecabinet(5-15P)

FinishPretreatedsteelcoatedwithRAL7035lightgraytextured,low-glosspolyesterpowderpaint.Otherpaintfinishesavailable—contactHoffmanCustomerServicefordetails.

LoadRatingWARNING:Thecabinetmustbesafelyandcorrectlymountedtothewalltosupportthetotalweightofthecabinetanditscontents.Duetovariousapplicationsandwallconstructions,consultationwithastructuralengineerandanalysisofthemountingwallisadvised.Bulletin:DWS12

StandardProduct PROTEKSingleWindowDoorULType1FanandFilterPackages

CatalogNumber AxBxCin. AxBxCmmRackUnits

AccessoryPanels

StandardPanels

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDW242424GF 24.00 x 24.00 x 24.00 610 x 610 x 610 12 PTP2424A CP2424 PTRA1924TPL PTRA1924THLPTDW362424GF 36.50 x 24.00 x 24.00 927 x 610 x 610 19 PTP3624A CP3624 PTRA1936TPL PTRA1936THLPTDW482424GF 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 PTP4824A CP4824 PTRA1948TPL PTRA1948THL

TechnicalOperatingInformationFanUnit(6-in.FanwithCord) ReplacementFilterNo.AFLTR10Hz VoltageVAC CFM W@50/60Hz FullLoadAmp@50/60Hz NoiseSIL(db)50/60 115 200/240 36/32 .45/.36 50/56

Page 12: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

905

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

ThermalPerformanceforFanandFilterPackagesPROTEKFanandFilterPackagescalculatedthermalperformanceMax.InternalTemperature:100FVoltage/Hertz:115VAC/60HzFilters:Clean(Regularcleaningrequiredtomaintainairflow)AirVolume:200CFM(ExactCFMdependantonVoltage,Frequency,andfilterefficiency)Max.Elevation:6,000ft.(ContactHoffmanforelevationsabove6,000ft.)

ThermalPerformance PROTEK®FanandFilterPackagesAmbientTemperature(°F) Watts(Heat)Dissipated100 or above Not recommended

Consider PROTEK Air Conditioner Package95 31690 63285 94880 126475 158070 189665 221260 252855 2844

Watts = .316 x CFM x delta T (degrees F) (at sea level)

Delta T = Max internal temperature (degrees F) – Ambient external temperature (degrees F)

Ambient temperature is the air temperature in and around the intake opening of the cabinet. Fan cooling can never cool the equipment below ambient temperature.

Page 13: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

906

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK®Single-DoorThermalACPackage,ULandNEMAType4or12

IndustryStandardsPROTEKAirConditionerPackagesIndoor(Type12)UL508AListed;Type12;FileNumberE619967cULListedperCSAC22.2No.94;Type12;FileNumberE61997

NEMA/EEMAC:Type12IEC60529,IP55PROTEKAirConditionerPackagesOutdoor(Type4)UL508AListed;Type12,4;FileNumberE619967cULListedperCSAC22.2No.94;Type12,4;FileNumberE61997

NEMA/EEMAC:Type12,4IEC60529,IP66

ApplicationThePROTEK®ThermalPackageisanexcellent,off-the-shelfchoiceformounting19-in.racknetworkequipmentinwetordirtyenvironmentswherefiltrationorairconditioningisrequiredandfloorspaceisatapremium.CompleteFanandFilterandAirConditionerPackagesareavailabletomatchapplicationrequirements.

Features• Soliddoorprovidescompletephysicalandvisualprotection• Windowdoor,madewithscratch-resistantsafetyglass,provides

equipmentmonitoringwithoutopeningthedoortominimizecontamination

• Fullyweldedandgroundbodyanddoorconstructionforlong-termgoodappearanceanddurability

• Foam-in-placeseamlessgasketarounddoorsealsagainstoutdoorairinfiltration;isnon-absorbingandchemicallyresistant

• Type12cabinetshavewindowdoorsandalockingwingknobwithtwokeys.Theyprovidesecurityandconvenienceinindoorapplications.

• Type4cabinetshavesoliddoorsandapadlock-capable,tamper-resistant,quarter-turnlatch(toolincluded).Theyprovideeasyoperationandlockingoptionsinindoorandoutdoorapplications.

• Onesetofadjustabletappedrackanglesincluded• Optionalsquare-hole(.375-in.)rackanglesavailableforequipment

mountingflexibility• Rackanglesareplatedandself-groundingfordurabilityandsafety• Collarstudsprovidedonbackofcabinetformountingaccessory

panels• Accessorypanelsformountingadditionalaccessoriesattheback

ofthecabinetincludetie-downpointsandpre-drilledholes• Plenumratedforuseinairexchangeareas• Cabinetshippedwithairconditioneruninstalled

Specifications• Doorsmadeof16gaugesteel;bodymadeof14gaugesteel• Convenientstudsprovidedonbothdoorandbodyforbonding

andgrounding• Rackanglestapped10-32perEIAstandards;madeof12gauge

self-groundingplatedsteel• Windowisclear,.25-in.thick,scratch-andimpact-resistantsafety

glass• Optionalpolycarbonatewindow(notplenumrated)canbefield-

orfactory-installed.ContactHoffmanCustomerServiceforfactoryinstallation.

• Twenty10-32screwsincluded• Right-side-mountedT4LineIndoor/OutdoorAirConditioner• Operateson110/115VAC50/60Hzlinevoltage• StandardNEMA15Apluginternaltothecabinet(5-15P)• Seetablefortechnicaloperatinginformation• Routinemaintenancerequiredforoptimumperformance(see

servicemanual)

FinishPretreatedsteelcoatedwithRAL7035lightgraytextured,low-glosspolyesterpowderpaint.Otherpaintfinishesavailable—contactHoffmanCustomerServicefordetails.

LoadRatingWARNING:Thecabinetmustbesafelyandcorrectlymountedtothewalltosupportthetotalweightofthecabinetanditscontents.Duetovariousapplicationsandwallconstructions,consultationwithastructuralengineerandanalysisofthemountingwallisadvised.Bulletin:DWS12

StandardProduct SingleWindow-DoorULType12AirConditionerPackages

CatalogNumber AxBxCin. AxBxCmmRackUnits

AccessoryPanels

StandardPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDW242424GA 24.00 x 24.00 x 24.00 610 x 610 x 610 12 PTP2424A CP2424 PTRA1924TPL PTRA1924THLPTDW362424GA 36.50 x 24.00 x 24.00 927 x 610 x 610 19 PTP3624A CP3624 PTRA1936TPL PTRA1936THLPTDW482424GA 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 PTP4824A CP4824 PTRA1948TPL PTRA1948THL

StandardProduct SingleSolid-DoorULType4AirConditionerPackages

CatalogNumber AxBxCin. AxBxCmmRackUnits

AccessoryPanels

StandardPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDS242424GA4 24.00 x 24.00 x 24.00 610 x 610 x 610 12 PTP2424A CP2424 PTRA1924TPL PTRA1924THLPTDS362424GA4 36.50 x 24.00 x 24.00 927 x 610 x 610 19 PTP3624A CP3624 PTRA1936TPL PTRA1936THLPTDS482424GA4 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 PTP4824A CP4824 PTRA1948TPL PTRA1948THL

TechnicalOperatingInformationACUnit(T150116G100) ReplacementFilterNo.10100091Hz VoltageVAC Phase BTU/[email protected].(E) FullLoadAmp Max.Amb.Temp.(ºF) Max.Amb.Temp.(ºC) CordandPlug60 (50) 110 - 115 1 800 (235 watts) 3.6 (3.8) 131 (125) 52 (52) 24-in. cord length 5-15PPlug

Page 14: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

907

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

ThermalPerformanceforAirConditionerPackagesPROTEKAirConditionercalculatedthermalperformanceACPerformance:800BTU/houror235wattsVoltage/Hertz:115VAC/60HzMax.AmbientTemperature:131FMin.AmbientTemperature:-40FMax.InternalTemperature:100F(Allowable)

ThermalPerformance PROTEK®AirConditionerPackagesAmbientTemperature(°F)

Watts(Heat)DissipatedCabinetHeight:24in.

Watts(Heat)DissipatedCabinetHeight:36in.

Watts(Heat)DissipatedCabinetHeight:48in.

130 15 N/A N/A120 88 73 59110 161 154 146100 234 234 23490 308 315 32280 381 396 41070 454 476 49860 527 557 58650 601 637 67440 674 718 762

N/A = Not applicable and not recommended in these applications

1 BTU = 3.413 watts

Page 15: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

908

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK®DHDouble-Hinge,ULandNEMAType4or12

Self-Closing Latch Type 4 Enclosures

IndustryStandards

UL508AListed;Type4or12;FileNumberE619967cULListedperCSAC22.2No.94;Type4or12;FileNumberE61997

NEMA/EEMAC:Type4or12IEC60529,IP66orIP55

ApplicationPROTEK®DHCabinetsprotectequipmentinwetordirtyenvironmentsandcanbepole-orwall-mounted.Availablewithreversibleleftorrighthinging,thecabinetswingsopentoprovideeasyequipmentserviceandinstallationaccess.

Features• Type12cabinetsavailablewithsolidorwindowdoorsandhave

alockingwingknobwithtwokeys.Theyprovidesecurityandconvenienceinindoorapplications.

• Type4cabinetshavesoliddoorsandapadlock-capablequarter-turnlatch.Theyprovideeasyoperationandlockingoptionsinindoorandoutdoorapplications.

• Soliddoorprovidescompletephysicalandvisualprotection• Windowdoor,madewithscratchresistantsafetyglass,allows

equipmentmonitoringwithoutopeningthedoortominimizecontamination

• Double-hingedforeasyequipmentaccess• Frontaccesstocenterbodyhingingandbacksectionlatches• Exclusivetoollessself-fasteninglatchiseasytoopen,yet

automaticallyclosessecurely• Latchonfrontofdooreliminatesneedtoaccesssidestoopendoor

orbacksectionlatches• Latch-freesidespermitsideofcabinettobeinstalledtightlyintoa

corner• Fullyweldedandgroundbodyanddoorconstructionforlong-

termgoodappearanceanddurability• Foam-in-placeseamlessgasketarounddoorsealsagainstoutdoor

airinfiltration;isnon-absorbingandchemicalresistant• Onesetofadjustabletappedrackanglesincluded• Optionalsquareholerackanglesavailableforequipment

mountingflexibility• Rackanglesareplatedandself-groundingfordurabilityandsafety

• Collarstudsprovidedonbackofcabinetformountingaccessorypanels

• Accessorypanelsformountingadditionalaccessoriesatthebackofthecabinetincludetie-downpointsandpre-drilledholes

• Plenumratedforuseinairexchangeareas• Availablemodificationsincludepaintcolors,holesandcutouts,

andcustomsizes

Specifications• Doorsandbodymadeof14gaugesteel• Convenientstudsprovidedoncentersectionforbondingand

grounding• Rackanglestapped10-32perEIAstandards;madeof12gauge

self-groundingplatedsteel• Windowisclear,.25in.thick,scratchandimpactresistantsafety

glass• Optionalpolycarbonatewindow(notplenumrated)canbefield-

orfactory-installed.ContactHoffmanCustomerServiceforfactoryinstallation.

• Twenty10-32screwsincluded

FinishPretreatedsteelcoatedwithRAL7035lightgraytextured,lowglosspolyesterpowderpaint.Otherfinishesavailable–contactHoffmanCustomerService.

LoadRatingHEIGHT RATING 16.00(in.)100lb.(45.4kg)20.00(in.)100lb.(45.4kg)24.00(in.)100lb.(45.4kg)36.00(in.)125lb.(56.7kg)48.00(in.)175lb.(79.4kg)

OptionsSeetheappropriateoptionformoreinformation.Optionsinclude:

PROTEK®DHType1,4or12Double-HingedWall-MountCabinetAccessoryPanelsPROTEK®PolycarbonateWindowInsertsPROTEK®RackAnglesBulletin:DWS12

Page 16: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

909

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct 

CatalogNumber AxBxCin. AxBxCmm RackUnits DoorStyle UL/NEMAType IPRating AccessoryPanel StandardPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDHS162415G4 16.00 x 24.00 x 15.00 406 x 610 x 381 8 Solid 4 IP66 PTPDH1624A A24P16 PTRA1916TPL PTRA1916THLPTDHS162415G 16.00 x 24.00 x 15.00 406 x 610 x 381 8 Solid 12 IP55 PTPDH1624A A24P16 PTRA1916TPL PTRA1916THLPTDHW162415G 16.00 x 24.00 x 15.00 406 x 610 x 381 8 Window 12 IP55 PTPDH1624A A24P16 PTRA1916TPL PTRA1916THLPTDHS202415G4 20.00 x 24.00 x 15.00 508 x 610 x 381 10 Solid 4 IP66 PTPDH2024A A24P20 PTRA1920TPL PTRA1924THLPTDHS202415G 20.00 x 24.00 x 15.00 508 x 610 x 381 10 Solid 12 IP55 PTPDH2024A A24P20 PTRA1920TPL PTRA1924THLPTDHW202415G 20.00 x 24.00 x 15.00 508 x 610 x 381 10 Window 12 IP55 PTPDH2024A A24P20 PTRA1920TPL PTRA1924THLPTDHS242415G4 24.00 x 24.00 x 15.00 610 x 610 x 381 12 Solid 4 IP66 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHS242415G 24.00 x 24.00 x 15.00 610 x 610 x 381 12 Solid 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHW242415G 24.00 x 24.00 x 15.00 610 x 610 x 381 12 Window 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHS362415G4 36.50 x 24.00 x 15.00 927 x 610 x 381 19 Solid 4 IP66 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHS362415G 36.50 x 24.00 x 15.00 927 x 610 x 381 19 Solid 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHW362415G 36.50 x 24.00 x 15.00 927 x 610 x 381 19 Window 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHS482415G4 48.50 x 24.00 x 15.00 1232 x 610 x 381 26 Solid 4 IP66 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THLPTDHS482415G 48.50 x 24.00 x 15.00 1232 x 610 x 381 26 Solid 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THLPTDHW482415G 48.50 x 24.00 x 15.00 1232 x 610 x 381 26 Window 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THLPTDHS242424G4 24.00 x 24.00 x 24.00 610 x 610 x 610 12 Solid 4 IP66 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHS242424G 24.00 x 24.00 x 24.00 610 x 610 x 610 12 Solid 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHW242424G 24.00 x 24.00 x 24.00 610 x 610 x 610 12 Window 12 IP55 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHS362424G4 36.50 x 24.00 x 24.00 927 x 610 x 610 19 Solid 4 IP66 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHS362424G 36.50 x 24.00 x 24.00 927 x 610 x 610 19 Solid 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHW362424G 36.50 x 24.00 x 24.00 927 x 610 x 610 19 Window 12 IP55 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHS482424G4 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 Solid 4 IP66 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THLPTDHS482424G 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 Solid 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THLPTDHW482424G 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 Window 12 IP55 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL

Page 17: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

910

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK®DHDouble-HingeFanandFilterThermalPackages,ULandNEMAType1

IndustryStandards

UL508AListed;Type1;FileNumberE619967cULListedperCSAC22.2No.94;Type1;FileNumberE61997

NEMA/EEMAC:Type1IEC60529,IP55

ApplicationPROTEK®FanandFilterPackagesareidealforprotectingsensitive19-in.rackequipmentfromharmfulenvironmentalcontaminantssuchasfallingdirt,dustanddrippingwater.Useforapplicationswheretheambientaircanbeusedtocooltheinternalequipmentandwhereprotectionfromfallingdirtanddrippingwaterisneeded.Filtersassistinremovingcontaminantsandareeasilyremovedforperiodiccleaningwithoutaccessingthecabinet.Top-mountedfansprovideincreasedairflowandmaximizeheatdissipationofinternallymountedequipment.Bothtop-mountedfansandbottom-mountedintakefiltersarepositionedawayfrom19-inchrack-mountingareas.

Features• Soliddoorprovidescompletephysicalandvisualprotection• Windowdoor,madewithscratch-resistantsafetyglass,provides

equipmentmonitoringwithoutopeningthedoortominimizecontamination

• Fullyweldedandgroundbodyanddoorconstructionforlong-termgoodappearanceanddurability

• Foam-in-placeseamlessgasketarounddoorsealsagainstoutdoorairinfiltration;isnon-absorbingandchemicallyresistant

• Type1cabinetshavewindowdoorsandalockingwingknobwithtwokeys.Theyprovidesecurityandconvenienceinindoorapplications.

• Onesetofadjustabletappedrackanglesincluded

• Optionalsquarehole(.375in.)rackanglesavailableforequipmentmountingflexibility

• Rackanglesareplatedandself-groundingfordurabilityandsafety• Collarstudsprovidedonbackofcabinetformountingaccessory

panels• Accessorypanelsformountingadditionalaccessoriesattheback

ofthecabinetincludetie-downpointsandpre-drilledholes• Plenumratedforuseinairexchangeareas• Double-hingedforeasyequipmentaccess• Frontaccesstocenterbodyhingingandbacksectionlatches• Exclusivetool-lessself-fasteninglatchiseasytoopen,yet

automaticallyclosessecurely• Latchonfrontofdooreliminatesneedtoaccesssidestoopendoor

orbacksectionlatches• Latch-freesidespermitcabinettobeinstalledtightlyintoacorner

Specifications• Doorsmadeof16gaugesteelandbodymadeof14gaugesteel• Convenientstudsprovidedonbothdoorandbodyforbonding

andgrounding• Rackanglestapped10-32perEIAstandards;madeof12gauge

self-groundingplatedsteel• Windowisclear,.25-in.thick,scratch-andimpact-resistantsafety

glass• Optionalpolycarbonatewindow(notplenumrated)canbefield-

orfactory-installed.ContactHoffmanCustomerServiceforfactoryinstallation.

• Twenty10-32screwsincluded• Pagodatop-mounted6-in.fanandbottom-mounted10-in.filter

inlet• Topfanshroudprotectscabinetandfanfromfallingdebrisand

drippingwater• Bottom-mountedairinletwithoutsideremovableandcleanable

filter• Regularfiltercleaningrequiredforoptimumthermalperformance• Operateson110/115VAC50/60Hzlinevoltage• StandardNEMA15Apluginternaltothecabinet(5-15P)

FinishPretreatedsteelcoatedwithRAL7035light-gray,textured,low-glosspolyesterpowderpaint.Otherpaintfinishesavailable—contactHoffmanCustomerServicefordetails.

LoadRatingWARNING:Thecabinetmustbesafelyandcorrectlymountedtothewalltosupportthetotalweightofthecabinetanditscontents.Duetovariousapplicationsandwallconstructions,consultationwithastructuralengineerandanalysisofthemountingwallisadvised.Bulletin:DWDH2

StandardProduct Double-HingedWindow-DoorType1FanandFilterPackages

CatalogNumber AxBxCin. AxBxCmmRackUnits

AccessoryPanels

StandardPanel

AdditionalOptionalRackAngles(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDHW242424GF 24.00 x 24.00 x 24.00 610 x 610 x 610 12 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHW362424GF 36.50 x 24.00 x 24.00 927 x 610 x 610 19 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHW482424GF 48.50 x 24.00 x 24.00 1232 x 610 x 610 26 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL

 LoadRatings

HeightMax.LoadRackAnglesMountedtoCenterSection

Max.LoadAccessoryPanelMountedRearSectiontoCollarStuds

16 in. 100 lb. 50 lb.20 in. 100 lb. 80 lb.24 in. 100 lb. 100 lb.36 in. 125 lb. 200 lb.48 in. 175 lbs. 300 lb.

Page 18: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

911

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

TechnicalOperatingInformationFanUnit(6-in.FanwithCord) ReplacementFilterNo.AFLTR10Hz VoltageVAC CFM W@50/60Hz FullLoadAmp@50/60Hz NoiseSIL50/60 115 200/240 36/32 .45/.36 50/56 dB

ThermalPerformanceforFanandFilterDHPackagesPROTEKFanandFilterPackagescalculatedthermalperformanceMax.InternalTemperature:100FVoltage/Hertz:115VAC/60HzFilters:Clean(Regularcleaningrequiredtomaintainairflow)AirVolume:200CFM(ExactCFMdependantonVoltage,Frequency,andfilterefficiency)Max.Elevation:6,000ft.(ContactHoffmanforelevationsabove6,000ft.)

ThermalPerformance PROTEK®FanandFilterPackagesAmbientTemperature(°F) Watts(Heat)Dissipated100 or above Not recommended

Consider PROTEK Air conditioner Package95 31690 63285 94880 126475 158070 189665 221260 252855 2844

Watts = .316 x CFM x Delta T (°F) (at sea level)

Delta T = Max internal Temperature (degrees F) – Ambient external Temperature (degrees F)

Ambient temperature is the air temperature in and around the intake opening of the cabinet. Fan cooling can never cool the equipment below ambient temperature.

Page 19: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

912

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK®DHDouble-HingeThermalACPackage,ULandNEMAType4or12

Self-Closing Latch Type 4 Enclosures

IndustryStandardsPROTEKAirConditionerPackagesIndoor(Type12)UL508AListed;Type12;FileNumberE619967cULListedperCSAC22.2No.94;Type12;FileNumberE61997

NEMA/EEMAC:Type12IEC60529,IP66PROTEKAirConditionerPackagesOutdoor(Type4)UL508AListed;Type12,4;FileNumberE619967cULListedperCSAC22.2No.94;Type12,4;FileNumberE61997

NEMA/EEMAC:Type12,4IEC60529,IP66

ApplicationPROTEK®DHThermalPackagesareanexcellent,off-the-shelfchoiceformounting19-in.racknetworkequipmentinwetordirtyenvironmentswherefiltrationorairconditioningisrequiredandfloorspaceisatapremium.Thesecompletepackagescanbemountedtoapoleorwallandhingedontheleftorright.Themountedcabinetswingsopentoprovideeasyequipmentserviceandinstallationaccess.CompleteFanandFilterandAirConditionerPackagesareavailabletomatchapplicationrequirements.

Features• Soliddoorprovidescompletephysicalandvisualprotection• Windowdoor,madewithscratch-resistantsafetyglass,provides

equipmentmonitoringwithoutopeningthedoortominimizecontamination

• Fullyweldedandgroundbodyanddoorconstructionforlong-termgoodappearanceanddurability

• Foam-in-placeseamlessgasketarounddoorsealsagainstoutdoorairinfiltration;isnon-absorbingandchemicallyresistant

• Type12cabinetshavewindowdoorsandalockingwingknobwithtwokeys.Theyprovidesecurityandconvenienceinindoorapplications.

• Type4cabinetshavesoliddoorsandapadlock-capable,tamper-resistant,quarter-turnlatch(toolincluded).Theyprovideeasyoperationandlockingoptionsinindoorandoutdoorapplications.

• Onesetofadjustabletappedrackanglesincluded• Optionalsquarehole(.375in.)rackanglesavailableforequipment

mountingflexibility• Rackanglesareplatedandareself-groundingfordurabilityand

safety• Collarstudsprovidedonbackofcabinetformountingaccessory

panels• Accessorypanelsformountingadditionalaccessoriesattheback

ofthecabinetincludetie-downpointsandpre-drilledholes• Plenumratedforuseinairexchangeareas• Double-hingedforeasyequipmentaccess• Frontaccesstocenterbodyhingingandbacksectionlatches• Exclusivetool-lessself-fasteninglatchiseasytoopen,yet

automaticallyclosessecurely• Latchonfrontofdooreliminatesneedtoaccesssidestoopendoor

orbacksectionlatches• Cabinetshippedwithairconditioneruninstalled

Specifications• Doorsmadeof16gaugesteelandbodymadeof14gaugesteel• Convenientstudsprovidedonbothdoorandbodyforbonding

andgrounding• Rackanglestapped10-32perEIAstandards;madeof12gauge

self-groundingplatedsteel• Windowisclear,.25-in.thick,scratch-andimpact-resistantsafety

glass• Optionalpolycarbonatewindow(notplenumrated)canbefield-

orfactory-installed.ContactHoffmanCustomerServiceforfactoryinstallation.

• Twenty10-32screwsincluded• Right-side-mountedT4LineIndoor/OutdoorAirConditioner• Operateson110/115VAC50/60Hzlinevoltage• StandardNEMA15Apluginternaltothecabinet(5-15P)• Seetablefortechnicaloperatinginformation• Routinemaintenancerequiredforoptimumperformance(see

servicemanual)

FinishPretreatedsteelcoatedwithRAL7035light-gray,textured,low-glosspolyesterpowderpaint.Otherpaintfinishesavailable—contactHoffmanCustomerServicefordetails.

LoadRatingWARNING:Thecabinetmustbesafelyandcorrectlymountedtothewalltosupportthetotalweightofthecabinetanditscontents.Duetovariousapplicationsandwallconstructions,consultationwithastructuralengineerandanalysisofthemountingwallisadvised.Bulletin:DWDH2

StandardProduct Double-HingedWindow-DoorType12AirConditionerPackages

CatalogNumber AxBxCin. AxBxCmmRackUnits

AccessoryPanels

StandardPanel

AdditionalOptionalRackAnglesl(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDHW242429GA 24.00 x 24.00 x 29.00 610 x 610 x 737 12 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHW362429GA 36.50 x 24.00 x 29.00 927 x 610 x 737 19 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHW482429GA 48.50 x 24.00 x 29.00 1232 x 610 x 737 26 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL

StandardProduct Double-HingedSolid-DoorType4AirConditionerPackages

CatalogNumber AxBxCin. AxBxCmmRackUnits

AccessoryPanels

StandardPanel

AdditionalOptionalRackAnglesl(TappedHoles)

AdditionalOptionalRackAngles(SquareHoles)

PTDHS242429GA4 24.00 x 24.00 x 29.00 610 x 610 x 737 12 PTPDH2424A A24P24 PTRA1924TPL PTRA1924THLPTDHS362429GA4 36.50 x 24.00 x 29.00 927 x 610 x 737 19 PTPDH3624A A36P24 PTRA1936TPL PTRA1936THLPTDHS482429GA4 48.50 x 24.00 x 29.00 1232 x 610 x 737 26 PTPDH4824A A48P24 PTRA1948TPL PTRA1948THL

Page 20: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

913

Networking:Wall-MountCabinets

PROTEK®Wall-MountandDouble-HingeCabinets

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

 LoadRatings

HeightMax.LoadRackAnglesMountedtoCenterSection

Max.LoadAccessoryPanelMountedRearSectiontoCollarStuds

16 in. 100 lb. 50 lb.20 in. 100 lb. 80 lb.24 in. 100 lb. 100 lb.36 in. 125 lb. 200 lb.48 in. 175 lb. 300 lb.

ThermalPerformanceforAirConditionerDHPackagesPROTEKAirConditionercalculatedthermalperformanceACPerformance:800BTU/houror235WattsVoltage/Hertz:115VAC/60HzMax.AmbientTemperature:131FMin.AmbientTemperature:-40FMax.InternalTemperature:100F(Allowable)

ThermalPerformance PROTEK®AirConditionerAmbientTemperature(°F)

Watts(Heat)DissipatedCabinetHeight:24in.

Watts(Heat)DissipatedCabinetHeight:36in.

Watts(Heat)DissipatedCabinetHeight:48in.

130 N/A N/A N/A120 63 27 N/A110 149 131 105100 234 234 23490 320 338 36480 405 442 49370 491 546 62360 576 649 75250 662 753 88140 747 857 1011

N/A = Not applicable and not recommended in these applications

1 BTU = 3.413 watts

Page 21: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

914

Networking:Wall-MountCabinets

PROTEK®Accessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK® Accessories

PROTEK®Single-DoorType4or12Wall-MountCabinetAccessoryPanelsWhereequipmentmountingspaceislimited,AccessoryPanelsincreasecabinetcapacitybyprovidingamountingsurfacefor19-in.equipmentandaccessoriesatthebackofthecabinet.Thepanelsmountoncollarstudsprovidedinthecabinet.TheyincludetiedownsforVELCRO®CableWrapsandmountingholesforrackanglebrackets,shelvesandotheraccessories.Panelshavewhitepaintfinish.

VELCRO is a trademark of Velcro Industries B.V.Bulletin:DWS12

CatalogNumber AxBin. AxBmm Material FitsCabinetSizePTP2424A 22.20 x 22.20 564 x 564 12 gauge steel 24.00 x 24.00PTP3624A 34.20 x 22.20 869 x 564 12 gauge steel 36.00 x 24.00PTP4824A 46.20 x 22.20 1173 x 564 12 gauge steel 48.00 x 24.00

PROTEK®DHType1,4or12Double-HingedWall-MountCabinetAccessoryPanelsWhereequipmentmountingspaceislimited,AccessoryPanelsincreasecabinetcapacitybyprovidingamountingsurfacefor19-in.equipmentaccessoriesatthebackofthecabinet.Thepanelsmountoncollarstudsprovidedinthecabinet.TheyincludetiedownsforVELCRO®CableWrapsandmountingholesforrackanglebrackets,shelves,andotheraccessories.Panelshaveawhitepaintfinishover12gaugesteel.

VELCRO is a trademark of VELCRO Industries B.V.Bulletin:DWS12

CatalogNumberDin./mm

Ein./mm FitsCabinetSize

PTPDH1624A 21.00533

13.00330

16.00 x 24.00

PTPDH2024A 21.00533

17.00452

20.00 x 24.00

PTPDH2424A 21.00533

21.00533

24.00 x 24.00

PTPDH3624A 33.00838

21.00533

36.00 x 24.00

PTPDH4824A 45.001143

21.00533

48.00 x 24.00

Page 22: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

915

Networking:Wall-MountCabinets

PROTEK®Accessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PROTEK®RackAnglesSquare-andtapped-holerackanglesfitintoPROTEK®single-anddouble-hingedcabinets.

Bulletin:DWS12

CatalogNumber HoleType FitsCabinetHeightRackUnits

PTRA1916TPL Tapped 16.00 7PTRA1916THL Square 16.00 7PTRA1920TPL Tapped 20.00 10PTRA1920THL Square 20.00 10PTRA1924TPL Tapped 24.00 12PTRA1924THL Square 24.00 12PTRA1936TPL Tapped 36.00 19PTRA1936THL Square 36.00 19PTRA1948TPL Tapped 48.00 26PTRA1948THL Square 48.00 26

PROTEK®PolycarbonateWindowInsertsPolycarbonatewindowinsertsprovideadditionalimpactprotection.Theyarefield-installedinplaceofthesafetyglassprovidedwiththeenclosure.Nospecialtoolsarerequired.

Bulletin:DWS12

CatalogNumber AxBin./mm FitsCabinetSize DescriptionPTWR1624POLY 16.00 x 24.00

406 x 61016.00 x 20.00 Clear, 0.23-in. thick

PTWR2024POLY 20.00 x 24.00 508 x 610

20.00 x 24.00 Clear, 0.23-in. thick

PTWR2424POLY 24.00 x 24.00 610 x 610

24.00 x 24.00 Clear, 0.23-in. thick

PTWR3624POLY 36.00 x 24.00 914 x 610

36.00 x 24.00 Clear, 0.23-in. thick

PTWR4824POLY 48.00 x 24.00 1219 x 610

48.00 x 24.00 Clear, 0.23-in. thick

Page 23: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

916

Networking:Wall-MountCabinets

L-BOX®Wall-MountCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

L-BOX® Wall-Mount Cabinet and Accessories

L-BOX®,Type1

IndustryStandards

UL1863Listed;FileNo.E230874UL508AListed;Type1;FileNumberE61997cULListedperCSAC22.2No.182.4;FileNo.E230874VentilationcomplieswithUL60950

DesignedinaccordancewithBICSITDMMTenthedition,Chapter7,TelecommunicationEnclosures(TE)EIA310-DIEC60529,IP30

ApplicationThelow-profile,vertically-orientedL-BOX®wall-mountcabinetisextremelyversatileandcanbeusedinpublicsettingstomount,storeandprotectnetworkequipment,patchpanelsandconnections.Thehinged,L-shapeddoorprovidesfullaccessontwosidestoinstalledequipmentwhilefixedrackanglesaccommodatevaryingequipmentsizes.

Features• Spring-loaded,self-retainedhingepinsallowdoorremoval• 120-degreedooropening• Quarter-turnlatcheswithkeylock(Code333)• Onesetoffixedrackanglesisincludedon24-and36-in.(610-and

914-mm)tallmodelsandtwoon48-in.(1219-mm)tallmodels• Rackangleson36-in.(914-mm)modelscanbepositionedeitherat

thetoporthebottomofthecabinet

• 36-and48-in.(914-and1219-mm)tallmodelshavespaceforpatchpanelorshelfbrackets

• Knockoutsfor4-in.(102-mm)fanontopandbottomofcabinet• Wiringknockouts(7/8in.,1-3/8in.,and3in.)ontopandbottomof

cabinet.Two3-in.cableentryknockoutsonback.• Multiplecabletie-downpointsonbackofcabinet• Keyholemountingslotsspaced16.00in.(406mm)oncenterfor

easycabinetmounting• Includespackageoftwenty10-32mountingscrews

Specifications• Manufacturedfrom14gaugemildsteel• Self-groundingmountinganglesmadeof12gaugeplatedsteel• Bondingprovisionondoor• Groundstudonbody• EIAUniversal5/8-5/8-1/2in.rackanglemountingholepattern

matchesindustrystandards.Holesaretapped10-32.

FinishPretreatedsteelcoatedwithRAL7035light-graytextured,low-glosspolyesterpowderpaint.Otherfinishesavailable—contactHoffmanCustomerService.

LoadRating75lb.(34.0kg)Bulletin:DWS1

StandardProduct CatalogNumber AxBxCin. AxBxCmm H(in.) H(mm) RackUnitsDBL242412G 24.00 x 24.00 x 12.34 610 x 610 x 313 22.00 559 6DBL362412G 36.00 x 24.00 x 12.34 915 x 610 x 313 34.00 864 6DBL482412G 48.00 x 24.00 x 12.34 1220 x 610 x 313 46.00 1168 2 sets of 6

Page 24: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

917

Networking:Wall-MountCabinets

L-BOX®Wall-MountCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Page 25: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

918

Networking:Wall-MountCabinets

L-BOX®Wall-MountCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

BondingandGroundingKitProvidesthecableandmountinghardwarerequiredtogroundequipmenttothedoorandthebodyofthecabinet.Bulletin:DWS1

CatalogNumber DescriptionDBGRDK Bonding and Grounding Kit

DuplexOutletKit15Aduplexoutletisfactory-mountedinthree-sided,platedsteelenclosure.Outletenclosuremountsonhingesideofdoorinlowercornerofcabinet.Mountinghardwareprovided.Bulletin:DWS1

CatalogNumber Description CurrentRatingDBDXK Duplex Outlet Kit 15 A

FanFilterandFingerGuardKitLow-densityfilterkitfor4-in.(102-mm)and6-in.(152-mm)fans.Canalsobeusedasvent.Filterisremovableandcanbecleanedandreused.Mountinghardwareincluded.Bulletin:DTHRM,DWS1

CatalogNumber Description FitsAFLTR4LD Fan Filter and Finger Guard Kit 4-in. fansAFLTR6LD Fan Filter and Finger Guard Kit 6-in. fans

PatchPanelRackAnglesSwivelingrackanglesdrop45degreestoprovideconvenientaccesstoequipmentmountedonpatchpanels.Provideadditionalpatchpanellocationin36-and48-in.(914-and1219-mm)highcabinets.Madeofself-grounding,plated12gaugesteel.Mountinghardwareincluded.Setoftwo.Bulletin:DWS1

CatalogNumber Description RackUnitsDBPRA4U Patch Panel Rack Angles 4

Page 26: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

919

Networking:Wall-MountCabinets

L-BOX®Wall-MountCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

ShelvesShelvesprovideadditionalstoragein36-and48-in.(914-and1219-mm)tallcabinets.Madeofself-groundingplated16gaugesteel.75lb.(34.0kg)loadrating.RAL7035polyesterpowdercoatfinish.Bulletin:DWS1

CatalogNumber DescriptionLengthin./mm

Depthin./mm FitsCabinetDepth

DBSHELF8 Steel Shelf 19.05484

7.25184

8 in.

DBSHELF12 Steel Shelf 19.05484

11.08281

8 or 12 in.

StrutWall-MountingKitProvidessecuremountingforcabinet.RAL7035polyesterpowdercoatfinish.Bulletin:DWS1

CatalogNumber DescriptionLengthin./mm

DB24WMTK Strut Wall-Mounting Kit 24.00610

Page 27: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

920

Networking:Wall-MountCabinets

D-BOX™Wall-MountEnclosureandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

D-BOX™ Wall-Mount Enclosure and Accessories

D-BOX™,Type1

IndustryStandards

UL1863Listed;FileNo.E230874UL508AListed;Type1;FileNumberE61997cULListedperCSAC22.2No.182.4;FileNo.E230874VentilationcomplieswithUL60950

TelcordiaNEBSTMRequirements:PhysicalProtection,GR-63-CORE,Zone4.Testedwith100lb.(45.4kg)ofequipmentinstalled.DesignedinaccordancewithBICSITDMMTenthedition,Chapter7,TelecommunicationEnclosures(TE)EIA310-DIEC60529,IP40

ApplicationIdealforretailapplicationswhereitisnecessarytohouse19-in.networkequipmentinapubliclocation,thehorizontally-orientedD-BOX™isalow-profilecabinetwithahingeddoorforconvenientfrontaccessandacombinationoffixedandrotatingrackanglestoaccommodatevaryingequipmentsizes.

Features• Spring-loaded,self-retainedhingepinsallowdoorremoval

• Reversibledoorfitsflushtobodywithnoexposedcorners• Knockoutsfor4-in.fanontopandbottomofenclosure• Wiringknockouts(7/8in.,1-3/8in.,and3in.)ontopandbottomof

enclosure.Two3-in.cableentryknockoutsonback.• 120-degreedooropening• Multiplecabletie-downpointsonbackofenclosure• Quarter-turnlatchwithkeylock• Keyholemountingslotsspaced16.00in.(406mm)oncenterfor

easyenclosuremounting• Bossesprovidedformountingaccessoriessuchascablespools• Self-groundingmountinganglesmadeof12gaugegalvanized

steel• Patchpanelmountinganglesrotatedownforaccess• Flangearounddooropeningprotectsinterior• Bondingprovisionondoor• Groundstudonbody• EIAUniversal5/8-5/8-1/2in.verticalmountingholepattern

matchesindustrystandards.Holesaretapped10-32.• Includespackageoftwenty10-32mountingscrews

Specifications• Doormanufacturedfrom14gaugemildsteel• Bodymanufacturedfrom16gaugemildsteel

FinishPretreatedsteelcoatedwithRAL7035light-graytextured,low-glosspolyesterpowderpaint.Otherfinishesavailable—contactHoffmanCustomerService.

LoadRating100lb.(45.4kg)Bulletin:DWS1

Page 28: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

921

Networking:Wall-MountCabinets

D-BOX™Wall-MountEnclosureandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct CatalogNumber AxBxCin. AxBxCmm H(in.) H(mm) RackUnitsDBS24248G 24.00 x 24.00 x 8.34 610 x 610 x 212 22.00 559 4DBS36248G 36.00 x 24.00 x 8.34 915 x 610 x 212 34.00 864 4DBS48248G 48.00 x 24.00 x 8.34 1220 x 610 x 212 46.00 1168 4DBS242412G 24.00 x 24.00 x 12.34 610 x 610 x 313 22.00 559 6DBS362412G 36.00 x 24.00 x 12.34 915 x 610 x 313 34.00 864 6DBS482412G 48.00 x 24.00 x 12.34 1220 x 610 x 313 46.00 1168 6

Page 29: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

922

Networking:Wall-MountCabinets

D-BOX™Wall-MountEnclosureandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

BondingandGroundingKitProvidesthecableandmountinghardwarerequiredtogroundequipmenttothedoorandthebodyofthecabinet.Bulletin:DWS1

CatalogNumber DescriptionDBGRDK Bonding and Grounding Kit

DuplexOutletKit15Aduplexoutletisfactory-mountedinthree-sided,platedsteelenclosure.Outletenclosuremountsonhingesideofdoorinlowercornerofcabinet.Mountinghardwareprovided.Bulletin:DWS1

CatalogNumber Description CurrentRatingDBDXK Duplex Outlet Kit 15 A

EquipmentRackAnglesFixedrackanglescanbeaddedto36-in.and48-in.tallcabinetsforextra19-inrackequipmentmounting.Madeofsteelwithclearzincplating.EIAspacedholesaretapped10-32.Mountstoraisedpadsoncabinetinsidebackwithprovidedhardware.Bulletin:DWS1

CatalogNumber Description RackUnitsDBERA4U Equipment Rack Angles 4DBERA6U Equipment Rack Angles 6

FanFilterandFingerGuardKitLow-densityfilterkitfor4-in.(102-mm)and6-in.(152-mm)fans.Canalsobeusedasvent.Filterisremovableandcanbecleanedandreused.Mountinghardwareincluded.Bulletin:DTHRM,DWS1

CatalogNumber Description FitsAFLTR4LD Fan Filter and Finger Guard Kit 4-in. fansAFLTR6LD Fan Filter and Finger Guard Kit 6-in. fans

PadlockKitKitincludesfieldinstallablehaspandstaple.Fitspadlockswithmaximum5/16in.(8mm)shacklediameter.Nodrillingorlayoutrequired.Includesmountinghardware.Bulletin:DWS1

CatalogNumber DescriptionDBPDLK Padlocking Kit

Page 30: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

923

Networking:Wall-MountCabinets

D-BOX™Wall-MountEnclosureandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PatchPanelRackAnglesSwivelingrackanglesdrop45degreestoprovideconvenientaccesstoequipmentmountedonpatchpanels.Provideadditionalpatchpanellocationin36-and48-in.(914-and1219-mm)highcabinets.Madeofself-grounding,plated12gaugesteel.Mountinghardwareincluded.Setoftwo.Bulletin:DWS1

CatalogNumber Description RackUnitsDBPRA4U Patch Panel Rack Angles 4

ShelvesShelvesprovideadditionalstoragein36-and48-in.(914-and1219-mm)tallcabinets.Madeofself-groundingplated16gaugesteel.75lb.(34.0kg)loadrating.RAL7035polyesterpowdercoatfinish.Bulletin:DWS1

CatalogNumber DescriptionLengthin./mm

Depthin./mm FitsCabinetDepth

DBSHELF8 Steel Shelf 19.05484

7.25184

8 in.

DBSHELF12 Steel Shelf 19.05484

11.08281

8 or 12 in.

StrutWall-MountingKitProvidessecuremountingforcabinet.RAL7035polyesterpowdercoatfinish.Bulletin:DWS1

CatalogNumber DescriptionLengthin./mm

DB24WMTK Strut Wall-Mounting Kit 24.00610

Page 31: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

924

Networking:Wall-MountCabinets

POLYPRO®WiFi,Type4X

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

POLYPRO® WiFi, Type 4X

POLYPRO®WiFi,Type4X

IndustryStandards

UL508AListed;Type4,4X,12,13;FileNo.E61997cULListedperCSAC22.2No94;Type4,4X,12,13;FileNo.E61997EnclosureflammabilityevaluatedperUL508AWindowflammabilityevaluatedperUL508A

NEMA/EEMACType4,4X,12,13CSAFileNo.42186;Type4,4X,12,13(solidcoversonly)IEC60529,IP66

ApplicationPOLYPRO®WiFienclosuresprovideprotectionforwirelessequipmentinbothindoorandoutdoorlocations.ThepolyesterconstructionandwoodpanelallowWiFiandWLANsignalstopassthroughtheenclosureunimpeded.Theyperformexceptionallywellinapplicationswhereharshchemicals,weatherextremes,acorrosiveenvironmentorflamesdemandtoughnessfromalightweightenclosure.Providingexcellentultravioletprotectionandatightenvironmentalseal,theseversatile,feature-richenclosuresarealsorecyclable.

Features• Non-glass-filledpolyestermaterialofferssuperiorUVresistance;

eliminatesfiberbloomassociatedwithfiberglass• Providesexcellentchemicalresistancetoabroadrangeof

solvents,alkalisandacids• Resistscrackingandprovidesexcellentimpactresistance• Lighter-weightthanfiberglass• Recyclable• Easy,dustlessin-fieldmodificationsusingstandardtools• Overlappingtongue-and-grooveraisedcoverandgasketprovide

secureType4Xseal• Removablesnap-hingecoverallowsforeasyaccesstocoverand

bodyformodifications• Moldedlayoutgridoninsideofbodyandsolidcoversassistswith

componentmounting• Molded-inembossesforrearpanelmounting• Internalrailsystemandadjustablepanelblocksallowforpanel

heightadjustmentandinstallationofmultiplepanels

Specifications• Scratch-resistantpolycarbonatewindows• Standardmodelsincludebodyandcover,twomountingfeet,two

latchassemblieswithoptionalcoverscrewsandhardware,and3/4-in.plywoodpanel

FinishPolyestermaterialisRAL7035light-graytexturedfinishinsideandoutBulletin:DWS12

Page 32: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

925

Networking:Wall-MountCabinets

POLYPRO®WiFi,Type4X

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

StandardProduct 

CatalogNumber AxBxCin./mm DoorType

PanelSizeDxEin./mm

Fin./mm

Gin./mm

Hin./mm

Jin./mm

Lin./mm

Min./mm

Nin./mm

Win./mm

D664WF 6.12 x 6.12 x 4.38 155 x 155 x 111

Solid 4.88 x 2.88124 x 73

4.32110

7.38187

2.5665

3.9199

8.15207

——

——

5.23133

D664WFW 6.12 x 6.12 x 4.38 155 x 155 x 111

Window 4.88 x 2.88124 x 73

4.32110

7.38187

2.5665

3.9199

8.15207

4.25108

2.2557

5.23133

D16148WF 16.12 x 14.01 x 8.35 409 x 356 x 212

Solid 14.75 x 12.88375 x 327

8.27210

17.27439

12.56319

7.91201

18.04458

——

——

15.32389

D16148WFW 16.12 x 14.01 x 8.35 409 x 356 x 212

Window 14.75 x 12.88375 x 327

8.27210

17.27439

12.56319

7.91201

18.04458

14.25362

12.25311

15.32389

Page 33: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

926

Networking:Wall-MountCabinets

POLYPRO®WiFi,Type4X

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

AdjustablePanelBlockKitPanelblocksslideinsidePOLYPROinternalrailsystemforpanelheightadjustmentwithintop5in.ofenclosure.Allowsforinstallationofmultiplepanels.Bulletin:PCRY

CatalogNumber Qty.APNLBLK 4

Includes Allen wrench

PolyesterMountingBracketKitsReplacementPOLYPROmountingbracketsaresoldinsetsoftwoandincludehardwareformountingtoenclosure.Included with standard POLYPRO models.Bulletin:PCRY

CatalogNumber Description(in.) Qty.APOLYFT4 4.00 2APOLYFT6 6.00 2APOLYFT8 8.00 2APOLYFT10 10.00 2APOLYFT12 12.00 2APOLYFT14 14.00 2APOLYFT16 16.00 2

Page 34: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

927

Networking:Wall-MountCabinets

POLYPRO®WiFi,Type4X

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

AluminumSwing-OutPanelsIncludesfourPOLYPROAdjustablePanelBlocks.Noenclosuremodificationisrequiredforinstallation.Bulletin:PCRY

CatalogNumber DxE(in.) DxE(mm)A64PSWPNL 5.00 x 3.62 127 x 92A66PSWPNL 5.00 x 5.62 127 x 143A86PSWPNL 7.00 x 5.62 178 x 143A88PSWPNL 7.00 x 7.62 178 x 194A108PSWPNL 9.00 x 7.62 229 x 194A1010PSWPNL 9.00 x 9.62 229 x 244A1210PSWPNL 11.00 x 9.62 279 x 244A1412PSWPNL 13.00 x 11.62 330 x 295A1614PSWPNL 15.00 x 13.62 381 x 346A1816PSWPNL 17.00 x 15.62 432 x 397

StainlessSteelLatches(Padlockable) StainlessSteelLatchescanberetrofittedonallPOLYPROmodelswithnomodificationordrillingrequired.Hinge/latchconstructedofcorrosion-resistantpolyesterwithaType316Lstainlesssteelbail.IncludedwithstandardPOLYPROmodels.Bulletin:PCRY

CatalogNumber Qty.AQRLSS6 2

HingeRetainers HingeRetainerscanbefield-installedwithoutmodificationtoPOLYPROhingesforapplicationswhereeasycoverremovalisnotdesired.Tworetainersperenclosureisrecommended.Kitincludestenhingeretainers.Bulletin:PCRY

CatalogNumber Description Pkg.Qty.AHGCLP POLYPRO Hinge Retainers 10

Page 35: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

928

Networking:Wall-MountCabinets

FiberglassHinge-CoverType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Fiberglass Hinge-Cover Type 4X WiFi Cabinet and Accessories

Hinge-CoverWiFi,Type4X

IndustryStandards

UL508AListed;Type4,4X,12,13;FileNo.E61997cULListedperCSAC22.2No94;Type4,4X,12,13;FileNo.E61997EnclosureflammabilityratingperUL508

NEMA/EEMACType4,4X,12,and13WindowflammabilityratingperUL508CSAFileNo.LR42186:Type4,4X,12,and13IEC60529,IP66Cabinetswithsoliddoorsareplenumrated.

ApplicationThefiberglassWiFiCabinetisasecure,hingedenclosurethatdoesnotimpedeWiFiorWLANsignals.Itisidealforhousingwirelessequipmentinlocationssuchastunnels,floorvaults,marinas,outsidewallsorrooftops.

Features• Fiberglassiseasilypunched,drilled,filedorsawed• Seamlessfoam-in-placegasketassureswatertightanddusttight

seal• Molded-in-placethreadedbrassinsertsandplatedsteelscrewsare

providedformountingoptionalpanelsandterminalblockkits• RemovablehingedcoverattachedtobodywithType316stainless

steelhingepin• ScrewcoverenclosuresaresecuredwithtwocaptivatedType316

stainlesssteelslottedcross-pointcoverscrews• Availablequick-releaselatchesarecorrosion-resistantpolyester

locatedincornerstoprovideunobstructedaccesstoenclosure• Knockoutpadlockprovisionsincludedineachlatch

Specifications• Enclosureanddoormadeofmoldedfiberglasspolyesterthat

resistschemicalsandtemperaturechange• Scratch-resistantGELexanMargard®windowsarepermanently

bondedinplace• Polyestermountingbracketsandstainlesssteelattachmentscrews

areprovidedwitheachenclosure• Hingepinandbailarecorrosion-resistantType316stainlesssteel• Includesa3/4-in.plywoodpanelformountingequipment

FinishFiberglassmaterialislightgrayinsideandout.Bulletin:DWS12

StandardProduct SolidDoor

CatalogNumber AxBxCin./mm Panel

PanelDXEin./mm

MountingGxHin./mm

OverallSizeLxWin./mm

Jin./mm

Kin./mm

Oin./mm

Pin./mm

Qin./mm

Rin./mm

Tin./mm

Uin./mm

D664CHSCFGP 6.00 x 6.00 x 4.00 152 x 152 x 102

A6P6WD 4.88 x 4.88124 x 124

6.94 x 4.00176 x 102

6.50 x 6.50165 x 165

3.2583

1.0025

4.25108

4.25108

5.64143

5.12130

.123

5.64143

D16148CHSCFGP 16.00 x 14.00 x 8.00 407 x 356 x 203

A16P14WD 14.75 x 12.88375 x 327

16.94 x 12.00430 x 305

16.55 x 14.55420 x 370

6.23158

2.0853

12.25311

14.25362

15.56395

15.12384

.154

13.56344

D181610CHSCFGP 18.00 x 16.00 x 10.00 457 x 407 x 254

A18P16WD 16.75 x 14.88425 x 378

18.94 x 14.00481 x 356

18.58 x 16.58472 x 421

7.66195

2.6668

14.25362

16.25413

17.53445

17.12435

.164

15.53394

Wood panels included with enclosure. Optional steel panels must be ordered separately.

StandardProduct WindowDoor

CatalogNumber AxBxCin./mm Panel

PanelDXEin./mm

MountingGxHin./mm

OverallSizeLxWin./mm

Jin./mm

Kin./mm

Oin./mm

Pin./mm

Qin./mm

Rin./mm

Tin./mm

Uin./mm

D664CHSCFGWP 6.00 x 6.00 x 4.00 152 x 152 x 102

A6P6WD 4.88 x 4.88124 x 124

6.94 x 4.00176 x 102

6.50 x 6.50165 x 165

3.2583

1.0025

4.25108

4.25108

5.64143

5.12130

.123

5.64143

D16148CHSCFGWP 16.00 x 14.00 x 8.00 407 x 356 x 203

A16P14WD 14.75 x 12.88375 x 327

16.94 x 12.00430 x 305

16.55 x 14.55420 x 370

6.23158

2.0853

12.25311

14.25362

15.56395

15.12384

.154

13.56344

D181610CHSCFGWP 18.00 x 16.00 x 10.00 457 x 407 x 254

A18P16WD 16.75 x 14.88425 x 378

18.94 x 14.00481 x 356

18.58 x 16.58472 x 421

7.66195

2.6668

14.25362

16.25413

17.53445

17.12435

.164

15.53394

Page 36: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

929

Networking:Wall-MountCabinets

FiberglassHinge-CoverType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Quick-ReleaseLatchKit Twofiberglass-reinforcedgraypolyesterlatcheswith316Lstainlesssteelbailandscrew-holeplugsareincludedineachpackage.SuppliedwithContinuousHinge,Type4XenclosuresandavailableforFiberglassHingedCoverWiFiCabinet,Type4X.Kitconvertsscrew-coverenclosurestoquick-releasewithoutmodification.Notoolsneededtoinstall.Padlockingprovisionisincluded.Bulletin:A48Y

CatalogNumber Description KitQty.AL48 Quick-Release Latch Kit 2

Page 37: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

930

Networking:Wall-MountCabinets

FiberglassHinge-CoverType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

PanelsforWiFiCabinetsandSmallWall-MountEnclosures

Panelsareavailableinbothsteelandwood.Steelpanelsare14gaugesteelwithawhitepolyesterpowderpaintfinish.Woodpanelsare3/4-in.plywoodandareunfinished.WoodpanelsaresuppliedwithFiberglassHinged-CoverandPOLYPRO®Type4XWiFiCabinets.Bulletin:DWS12,PNLJ,PNLWM

CatalogNumber MaterialPanelSizeDxE(in.)

PanelSizeDxE(mm) V(in.) V(mm)

A6P6 Steel 4.88 x 4.88 124 x 124 0.31 8A6P6WD Wood 4.88 x 4.88 124 x 124 0.31 8A16P14 Steel 14.75 x 12.88 375 x 327 0.25 6A16P14WD Wood 14.75 x 12.88 375 x 327 0.25 6A18P16 Steel 16.75 x 14.88 425 x 378 0.25 6A18P16WD Wood 16.75 x 14.88 425 x 378 0.25 6

Page 38: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

931

Networking:Wall-MountCabinets

ULTRX®FiberglassType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

ULTRX® Fiberglass Type 4X WiFi Cabinet and Accessories

ULTRX®WiFi,Type4X

IndustryStandards

UL508AListed;Type4,4X,12,13;FileNo.E61997cULListedperCSAC22.2No94;Type4,4X,12,13;FileNo.E61997EnclosureflammabilityratingperUL508WindowflammabilityratingperUL508

NEMA/EEMACType4,4X,12,13CSAFileNo.LR42186:Type4,4X,12,13IEC60529,IP66Cabinetswithsoliddoorsareplenumrated.

ApplicationIdealforlocationssuchastunnels,floorvaults,marinas,outsidewallsorrooftops,thelightweightULTRX®fiberglassWiFicabinetdoesnotimpedeWiFiorWLANsignalsandhasoptionalrackanglesthatcanbeaddedtosupport19-in.rack-mountequipment.

Features• Fiberglassiseasilypunched,drilled,filedorsawed• Seamlessfoam-in-placegasketassureswatertightanddusttight

seal• Enclosuremayberotated180degreesforleftandrighthinging• Molded-indripshieldsarestandardwitheachenclosure• Dooropens180degrees• Replaceablebreakawayhinges• Keylockinghandlestandard• Molded-inDINbosses• Moldedbossesondoorprovideadditionalmountingprovisions• Integralmountingrailsprovideinfinitepaneladjustmentfrontto

back• Optionaldatapocketishigh-impactthermoplastic

Specifications• Enclosureanddoormadeofmoldedfiberglasspolyesterthat

resistschemicalsandtemperaturechange• Impact-resistantpolycarbonatewindowispermanentlybondedin

place• Fiberglassmountingbracketsandstainlesssteelattachment

screwsareprovidedwitheachenclosure• Includesa3/4-in.plywoodpanelformountingequipment

FinishExteriorsurfacepaintedlight-grayacrylicenamelforenhancedUVprotection.Bulletin:DWS12

StandardProduct 

CatalogNumber AxBxCmm/in. DoorType

InternalDimensionsAxBxCmm/in. Panel

PanelSizeDxEmm/in.

MountingGxHmm/in.

WindowSizeMxNmm/in.

Fmm/in.

Jmm/in.

Kmm/in.

Pmm/in.

Qmm/in.

Rmm/in.

Smm/in.

Tmm/in.

DU606030P 608 x 595 x 321 23.94 x 23.44 x 12.64

Solid 608 x 595 x 32123.94 x 23.44 x 12.64

A24P24WD 533 x 53321.00 x 21.00

555 x 56821.86 x 22.36

498 x 48619.62 x 19.12

28711.31

50019.68

210.81

622.43

682.68

562.21

48919.25

48919.25

DU606030WP 608 x 595 x 321 23.94 x 23.44 x 12.64

Window 608 x 595 x 32123.94 x 23.44 x 12.64

A24P24WD 533 x 53321.00 x 21.00

555 x 56821.86 x 22.36

498 x 48619.62 x 19.12

28711.31

50019.68

210.81

622.43

682.68

562.21

48919.25

48919.25

Wood panel included with enclosure. Optional steel panels must be ordered separately.

Window size applies to window door cabinets only.

Page 39: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

932

Networking:Wall-MountCabinets

ULTRX®FiberglassType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Page 40: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

933

Networking:Wall-MountCabinets

ULTRX®FiberglassType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

ULTRX®Panel

Panelsareavailableinbothsteelandwood.Steelpanelsare14gaugesteelandhaveawhitefinish.Panelshavetwo.75-in.(19-mm)highedgeflanges.TheyrequirethePanelBracketKit,catalognumberUUPB,tomountintheenclosure.Woodpanelsare3/4-in.plywoodandareunfinished.Woodpanelsaresuppliedwiththeenclosures.Bulletin:DWS12,PNLWM

CatalogNumber MaterialDmm/in.

Emm/in.

Vmm/in.

A24P24 Steel 53321.00

53321.00

6.25

A24P24WD Wood 53321.00

53321.00

6.25

Requires UUPB Panel Bracket Kit to mount steel panel in cabinet.

SwingFrame

SwingFrameprovides19-in.rack-mountingcapabilitieswithU-Style(TypeRA)mountingholepattern.Quarter-turnlatchhas100-degreeswing.Adjustablemountingprovision.14gaugeplatedsteel.Includesmountinghardware.SwingframemaintainsenclosureratingifproperlyinstalledinaHoffmanenclosure.Swing Frame will not slide all the way forward in 400-mm-deep enclosures. Consult factory for more information.Bulletin:UX1Y

CatalogNumberFitsAxBmm/in.

Lmm/in.

Wmm/in.

RackUnits

UU6060SF 610 x 61024.00 x 24.00

54021.25

53521.08

11

UU7560SF 762 x 61030.00 x 24.00

68727.05

53521.08

14

Use UU6060SF with DATACOM ULTRX Fiberglass Type 4X WiFi Cabinet.

RackAngles(TypeRA)

Pairsoffull-lengthrack-mountinganglesareavailableformounting1-in.(483-mm)rack-mountedequipment.TypeRAanglesare14gaugesteelwith.281-in.(7-mm)diametermountingholes,spacedperEIAstandardRS-310-D(universalspacing).UseClipNutPackage(AN1032)toprovidetappedholesatdesiredlocations.Anglesandmountinghardwareareplatedsteel.Mountinghardwareisfurnished.Bulletin:UX1Y

CatalogNumber

FitsAxB

mm/in.Lmm/in.

Nmm/in.

RackUnits

Pkg.Qty.

UURA6060 610 x 61024.00 x 24.00

55221.75

10.38

12 2

UURA7560 762 x 61030.00 x 24.00

70527.75

19.75

15 2

Use UURA6060 with DATACOM ULTRX Fiberglass Type 4X WiFi Cabinet.

Page 41: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

934

Networking:Wall-MountCabinets

ULTRX®FiberglassType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

GroundingDeviceGroundingDeviceprovidesameanstoattachagroundingconductortoanULTRXSwing-OutPanelorSwing-OutFrame.Includesallinstallationhardwareandinstructions.Bulletin:UX1Y

CatalogNumber DescriptionUUGK ULTRX Grounding Device

KeylockKitandPadlockKit

KeylockKitorpushbutton-stylePadlockKitiseasilyinsertedinlatchholetopreventunauthorizedpersonnelfromgainingaccesstoenclosurecontents.Eachkitisfullyassembledforeasyinstallationinthefield.Type316stainlesssteelconstruction.Bulletin:UX1Y

CatalogNumber DescriptionUUHKL Keylock KitUUHPL Padlock Kit

UUHKL: Internal key components are not stainless steel.

UUHPL: Handles maintain UL 508A, Type 3, 4, 4X and 12 when properly installed on a Hoffman enclosure. Set up for 1/4-in. or 3/8-in. padlock.

ULTRX®MountingBracketKitKitisfield-installable.Corrosion-resistantfiberglassmaterial.Type316stainlesssteelmountinghardwareisincluded.Fourmountingbracketsperkit.Bulletin:UX1Y

CatalogNumber Description KitQty.UUMF Mounting Bracket Kit 4

Page 42: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

935

Networking:Wall-MountCabinets

ULTRX®FiberglassType4XWiFiCabinetandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Notes

Page 43: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

936

Networking:Wall-MountCabinets

SecurityWall-MountandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Security Wall-Mount and Accessories

SecurityDVRand19-in.RackEquipmentCabinet,Type1

IndustryStandards

UL508AListed;Type1

CSA;Type1NEMA/EEMAC;Type1IEC60529IP20EIA310-D(19-in.spacingforrackequipment)HoffmanisanISO9001company

ApplicationThesecabinetsprovidephysicalprotectionandaccesscontroltoDVR,19-in.equipmentorotherequipment.Mountthecabinetverticallyorhorizontallyonanysurface.

Features• Houses19-in.orshelf-mountequipment• Topcoverhastool-lessremoval,iscaptivatedbydoorandsecured

bykeylock,providingeasyaccessandinstallation• Solidtopcoverprotectsequipmentfromfallingdebris• Twostandardmodelsare4and6RUhigh• Radiuscornersgivestreamlinedappearanceandeliminatesharp

edges• Solidfrontdoorhas180-degreeopeningcontinuoushinge• Quarter-turnkeylockwithtwokeysondoor(code333)• Ventedsidesdissipateheatfromequipment• Afan-readycutoutisprovidedonleftside

• 14gaugesteelrackanglesareadjustablewithinthecabinetbody• Rackanglemountingsquareholes(.375x.375in.)withEIA

universalholespacing(1/4x5/8x5/8x1/4-in.)• Knockoutsonbottomandsidefordataandpowercables• Rubberfeetprovidesecureplacementandpreventscratches• Fastenersandcagenutsincluded

Specifications• Doorsandbodymadeof18gaugesteel;topcoveris16gauge

steel• Weldedsteelconstruction• OnesetofrackanglesincludedperEIAstandard• Includedinstallationinstructionsshowoptionalaccessories

FinishPretreatedsteelcoatedwithRAL9005black,light-textured,low-glosspolyesterpowderpaint

AccessoriesSee also Accessories.Rack-andPanel-MountPowerDistributionUnit(PDU)ReplacementKeysDualThermostatVELCRO®CableWrapVELCRO is a trademark of Velcro Industries B.V.Bulletin:D85,DACCY,DWS1

StandardProduct 

CatalogNumberAxBxCin./mm RackUnits(RU)

DVR4U 9.45x21.65x18.35240x550x466

4

DVR6U 12.99x21.65x18.35330x550x466

6

GeneralAccessories CatalogNumber Description KeyCodeE333KEY 2 replacement keys (fits all locks) 333A4AXFNGQ Fan, 115 VAC, plus

Page 44: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

937

Networking:Wall-MountCabinets

SecurityWall-MountandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Page 45: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

938

Networking:Wall-MountCabinets

SecurityWall-MountandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

19-in.ElectronicCase,Type1

IndustryStandardsNEMAType1EIA310-D/IEC297-1IEC60529,IP20

ApplicationPrimarilyusedtohouselabelectronics,lightweightElectronicCasesaccommodate19-in.sub-racks,chassisandpanelsinarigidventilatedcasewithintegralhandles.

Features• Aluminumextrusionsattachtofrontandrearframestocreatea

rigidsupportingframework• Sideson3Uand4Utallcasesarealuminumextrusionswith

integralcarryinghandle.6Utallcaseshavesteel(1.5-mm)sideswithrecessedhandles.9Uand12Utallcaseshave1.5-mmaluminumsideswithrecessedhandles.

• Removabletopandbottomcoversattachdirectlytothecaseframework

• Bottomcoverhasmultiplerowsofslotsforventilation• Rearcoverhasventilationlouvers• Coversare1-mmsteelon3U,4U,6Utallcasesand1-mmaluminum

on9Uand12Utallcases.Coversincludegroundingprovisions.• Caseframeworkisassembledwithrearcoverinstalled• Topcover,bottomcover,anti-skidfeetandmountinghardwareare

included• Optionaltip-upfootkit,equipmentguidesandcagenutsare

available

Specifications• Onepiecealuminumdie-castframeonfrontandrear• 19-in.rack-mountingprovisionsonbothfrontandrearframe

complywithEIA310-D/IEC297-1widespacing• 9-mmsquareholesaccommodatecagenutsformounting

FinishFrameworkandrearcoverhaveastone-graytexturedfinish(RAL7030).Topandbottomcoversandmetalsideshavealight-graytexturedfinish(RAL7035).

AccessoriesHardwareKitsSlideRailsTip-UpFootKit

Bulletin:DEC1

StandardProduct CatalogNumber AxBxCmm AxBxCin. F(mm) F(in.)EEC3U5250 166 x 520 x 500 6.50 x 20.50 x 19.70 133 5.24EEC4U5250 210 x 520 x 500 8.30 x 20.50 x 19.70 178 7.01EEC6U5260 299 x 520 x 600 11.80 x 20.50 x 23.60 267 10.51EEC9U5260 433 x 520 x 600 17.00 x 20.50 x 23.60 400 15.75EEC12U5260 566 x 520 x 600 22.30 x 20.50 x 23.60 533 20.98

Page 46: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

939

Networking:Wall-MountCabinets

SecurityWall-MountandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Tip-UpFootKitforElectronicCaseTip-upfeetcanbemountedonthebottomcovertoprovideanimprovedviewingangleforrackmountedequipmentinstalledinanelectroniccase.Intip-upposition,frontofcaseisraised1.38in.(35mm).Feetattachtoholesprovidedinthebottomcoverandincludeananti-skidrubberinsert.Feetaregrayplastic.Bulletin:DEC1

CatalogNumber Description KitIncludesEECFTP Tip-Up Foot Kit 2 tip-up feet, 2 standard feet and mounting hardware

SlideRailsforElectronicCaseSlideRailssupporta19-in.subrackorchassiswheninstalledinanelectroniccase.Railsattachtoprotrusionsontheinsidefrontandbackcastingsofthecaseframework.Theyarepositionableinincrementsof1.75in.(44mm)vertically.Sliderailsarealuminumextrusionswithaclearanodizedfinish.Theysnapintoplace;nomountinghardwareisrequired.Bulletin:DEC1

CatalogNumber FitsCase PackageIncludesEECCR50 500-mm deep 1 railEECCR60 600-mm deep 1 rail

HardwareKitsforElectronicCaseUsetomountElectronicCaseonrackangleswith9-mmsquareholes.Bulletin:DACCY,P20,X20

CatalogNumber Description PackageIncludes PackageQty.ECNSM6 M6 fastener package Pan head Posidrive plated M6 x 16 screws, ABS black plastic cup washers and plated cage nuts 8PM5CN M5 cage nut package M5 plated cage nuts 50ASM5 M5 screw package Pan head combination screws 20

Page 47: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

940

Networking:Wall-MountCabinets

19-in.Rack-Mount/DesktopCaseandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

19-in. Rack-Mount/Desktop Case and Accessories

19-in.Rack-Mount/DesktopCase,Type1

IndustryStandardsNEMAType1IEC60529,IP20ExteriorDimensionsEIA310-D/IEC297-1DIN41494Part1

ApplicationDesktopcaseshousecircuitboardsandotherelectronicequipmentinarigidframeworkwitheasyfrontandrearaccess.Rackcasesare19-in.rackmountablewithintegralmountingprovidedinthefrontbezel.

Features• Removabletopandbottomcoversattachdirectlytocase

frameworkformaintenanceconvenience• Bottomcoverhasmultiplerowsofholesforventilation• Frontbezelincludesmountingprovisionsfor19-in.rackmounting

aswellasmountingforfrontpaneloptionsforapplicationflexibility

• Topandbottomofframeworkhavemountingprovisionsforoptionalsupportrailsforapplicationflexibility.Mountingholesarespacedon10-mmcentersfronttoback.

• Caseframeworkisassembledforquickinstallation.Topcover,bottomcover,anti-skidfeetandmountinghardwareareincluded.

• Mountinghardwareforoptionalfrontandrearpanelsareincludedwithcaseforinstallationconvenience

Specifications• One-piecealuminumdiecastfrontbezelandrearbezelare

connectedfront-to-backwithaluminumextrusionstoformarigidstructuralframework

• Sideson3U-and4U-tallcasesarethealuminumfront-to-backextrusions.The6U-tallcasehastwoaluminumextrusionswithasteelmiddlepaneloneachside.

• Coversare1-mmsteelandhavegroundingprovisions

FinishFrameworkhasanRAL7030stone-graytexturedfinish.TopandbottomcovershaveanRAL7035light-graytexturedfinishontheoutsideandaplatedfinishontheinside.Bulletin:DEC1

StandardProduct 

CatalogNumber AxBxCmm/in.Emm/in.

Fmm/in.

Gmm/in.

Hmm/in. RackUnits

ERC3U4837 133 x 483 x 375 5.20 x 19.00 x 14.80

1315.14

1034.04

572.25

1104.33

3

ERC4U4843 177 x 483 x 435 7.00 x 19.00 x 17.10

1756.89

1475.77

1024.00

1556.08

4

ERC6U4843 266 x 483 x 435 10.50 x 19.00 x 17.10

26410.39

2359.27

1907.50

2439.58

6

Page 48: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

941

Networking:Wall-MountCabinets

19-in.Rack-Mount/DesktopCaseandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

FrontPanelsBlankfrontpanelprovidesameanstoclosefrontorrearofadesktopcase.Thesmoothanodizedsurfaceisidealformountingcontrolsormeters,etc.Thefrontpanelis2.5-mmthickandfitsintothe6-mm(0.24-in.)recessonfront(orrear)ofthecase.Hardwaretomountfrontpanelisfurnishedwithcase.Bulletin:DEC1

CatalogNumberDmm/in.

Hmm/in.

ERCFP3U48 120.54.74

110.04.33

ERCFP4U48 165.06.50

154.56.08

ERCFP6U48 253.89.99

243.49.58

RearPanelsRearpanelsare2.5-mmthickanodizedaluminum.Theyincludearowofventilationslots(vertical)alongtheupperedgeofpanel.6Ucovershavetworowsofslots.Hardwaretomountrearpanelisfurnishedwithcase.Bulletin:DEC1

CatalogNumberDmm/in.

Hmm/in.

Jmm/in.

ERCRP3U48 1214.74

1104.33

25.98

ERCRP4U48 1656.50

1556.08

25.98

ERCRP6U48 2549.99

2439.58

25.98

FrontHandlesHandlesfacilitatemovementofthedesktopcaseandinstallationofthecaseina19-in.rack.Theyaremountedtotherack-mountingflangesonthe19-in.frontbezel.Frontbezelshaveholespartiallydrilledandcountersunkforlocationandmustbedrilledthroughbeforehandleinstallation.Handlesaredie-castaluminumandfinishedinlight-gray(RAL7030).Packageincludestwohandleswithnecessarymountinghardware.Bulletin:DEC1

CatalogNumberERCFH3UERCFH4UERCFH6U

Page 49: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

942

Networking:Wall-MountCabinets

19-in.Rack-Mount/DesktopCaseandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

SupportRailKitSupportrailsarerecommendedformountingandsupportingtheweightofbulkycomponentsinsideadesktopcase.Supportrailshavemountingholesandrectangularslotsformountingcomponents.Railsare1.5-mmsteelwithaplatedfinish.M4nutsareweldedtotherailendsforeasyattachmenttothecase.Mountingholesinthedesktopcasearespacedon10-mmcentersfromfronttoback,allowingavarietyofpositionsforsupportrails.Supportrailkitincludesfrontrail,rearrailandmountinghardware.Bulletin:DEC1

CatalogNumber KitIncludesERCRF48 1 front rail, 1 rear rail and mounting hardware

Page 50: Specifiers Guide Chapter 9: Networking - Wall-Mount Cabinets

943

Networking:Wall-MountCabinets

19-in.Rack-Mount/DesktopCaseandAccessories

PH(763)422-2661•FX(763)422-2588•hoffmanonline.comSubjecttochangewithoutnotice ©2011PentairTechnicalProducts

Notes