timoleon specifiers guide

92
Specifier’s Guide L75624 L634 (56.49) X TN 13

Upload: timoleon

Post on 16-Mar-2016

248 views

Category:

Documents


4 download

DESCRIPTION

Underfloor heating, ventilation and solar heating. The total indoor environment.

TRANSCRIPT

Page 1: Timoleon Specifiers Guide

Specifier’s Guide

L75624 L634

(56.49) X

TN 13

Page 2: Timoleon Specifiers Guide
Page 3: Timoleon Specifiers Guide
Page 4: Timoleon Specifiers Guide

Timóleon.Manufacturers, designers and suppliers of energy efficient heating and ventilation systems.

Our Name (tim-oh-leon)

Timóleon is the name of a Greek statesman and general who secured the island of Sicily from the Carthaginians in 340BC.

Sicily is dominated by Mt Etna, Europe’s largest active volcano and archaeological evidence indicates that when Timóleon began the process of reconstruction, the Greeks realised that if they erected buildings on ground below which there were magma flows of energy from Mt Etna, these buildings would always be warm and dry.

Timóleon and his team understood the principles of underfloor heating 300 years before the Romans introduced the hypocaust.

Today Timóleon continues to pioneer innovative heating technologies.

2

Page 5: Timoleon Specifiers Guide

Introductio

n

Considered the most comfortable and energy efficient method of heating. Timóleon has a product for every floor type, all designed and tested to work with renewable technologies.

Controls are essential in creating a comfortable living environment. Aura brings together the heating, ventilation and hot water in a single simple-to-use system.

Whole house ventilation provides a controlled supply of fresh air to bedrooms and living areas and removes stale, damp air from bathrooms and kitchens. The system uses a Heat Recovery Unit to collect and re-use the energy that would otherwise be lost.

Solar thermal energy can be used in the heating system, not just for hot water. Our unique system, using Timóleon’s range of low temperature underfloor heating, enables a significant proportion of the heating demand to come from solar energy.

We have a range of services available from SAP and Code for Sustainable Homes assessment to servicing and commissioning of the underfloor heating or ventilation system.

Combining heating and ventilation technologies together to improve the indoor environment whilst also reducing energy costs.

Page 12. Underfloor Heating

Page 54. Aura Controls

Page 60. Ventilation & Heat Recovery

Page 66. Solar Heating

Page 72. Here to help

Page 6. Total Indoor Environment

3

Page 6: Timoleon Specifiers Guide

Product research and development is the basis on which our company has been built. With a commitment to continuous product development, we make sure that we are always at the forefront of our industry. We take great pride in delivering the highest quality products, systems and customer care.

The range of patented products available from Timóleon have been designed, tested and manufactured in the UK for UK constructions. Our products are all tested at BSRIA and, where appropriate, at TRADA as well. They are manufactured in an environmentally-responsible way, using as far as possible British-made component materials and all work very effectively with sources of renewable energy.

We dedicate an experienced Project Manager to look after every aspect of a project, from initial enquiry through to completion and beyond. Our technical team alongside your Project Manager will be able to help you with your project, always providing a prompt service for quotes, designs and specifications.

Working with Timóleon Guaranteed

Working with TimóleonPages 74-79

Innovative patented products

Experienced technical support

Tried systemsthat are innovative.Tested products designed for the future.Trusted by the UK construction industry.

We will not try to sell you a product which we believe will not work in your building.We maintain Professional Indemnity and Product Liability insurance which independently protects our customer’s systems.

4

Page 7: Timoleon Specifiers Guide

Introductio

n

Timóleon's unique product range is manufactured at its facility in Exeter.

5

Page 8: Timoleon Specifiers Guide

Total Indoor Environment is a concept that is at the core of the Timóleon philosophy – ensuring that the complementary technologies we bring together work effectively to achieve lower costs, both environmental and financial, whilst giving the user the comfort they want when they want.

Any particular technology does not stand alone but is affected and influenced by other devices used in the system. A holistic view of the system is needed to ensure that the benefits of using low carbon technologies are realised.

These technologies must be properly controlled with the ability for the individual to easily alter the comfort conditions to suit. Too often controls are independent, complicated and unintuitive which creates inefficient heating systems that are too hot, too cold or on for too long.

About the Total Indoor Environment

Why is this important?

Timóleon has an independent energy consultancy service, Tonos. Tonos is able to provide SAP and Code for Sustainable Homes assessment as well as Renewable Energy feasibility reports and MCS compliant heat loss calculations.

For more information on Tonos energy consultancy services, please seepage 76.

Tie it all together with Tonos...

Using a whole house ventilation system with heat recovery not

only improves air quality but pre-heats the incoming air using

energy from the extract that would have been otherwise lost. Comfort conditions are

improved especially when combined with a radiant

underfloor heating system.

Fundamental to any efficient system are good controls. The Aura control system brings together the controls for the heating, domestic hot water and ventilation making the home’s controls easier to install and simpler to use.

Whole House Ventilation

Aura Controls

Underfloor Heating

Solar energy can be used for heating. Usually the water collected in spring, autumn and winter is too cool to be used by radiators but using a Timóleon underfloor heating system with intelligent control and storage can double the useful contribution from solar thermal compared to a conventional twin coil cylinder or thermal store.

Comfortable room conditions can be achieved by using

underfloor heating. Timóleon underfloor heating products

work well with low water temperatures increasing the efficiency of the heat source

and facilitating the use of solar heating.

Solar Heating

Total Indoor Environment is the most efficient products & systems working together.

What is TIE?

6

Page 9: Timoleon Specifiers Guide

Total Ind

oo

r Enviro

nment

TIE creates the perfect indoor environment.

Solar thermal, controls & UFH

UFH & MVHR

A radiant heating system is acknowledged as being the most comfortable form of heating however by its nature a radiant system will take longer to warm the air when there are large draughts or high air changes, high incoming volumes of uncontrolled cold air can quickly reduce comfort levels.

This makes MVHR the perfect partner for UFH as it ensures that air coming into the building is “pre-warmed”. The two technologies complement each other to create better overall comfort conditions.

Energy collected using solar thermal can be used for the heating system. However, if the heating system is designed to operate at high water temperatures (as most conventional systems are) then it is difficult to make full use of the energy collected by the solar panels on, for example, a cloudy autumn day. This is because the temperature the energy is collected at is much lower than that needed by the heating system making it necessary to use a boiler to increase the water temperature.

A high performance emitter and renewable energy source can only be effective with good controls. The system must understand when to run the boiler or heat pump and when to use renewables such as solar thermal.

TIE in practice

The calculations were based on a new build 100m2 timber frame house using a heat pump.

SAP Rating 77

By incorporating the technologies into a house the SAP rating is improved.

SAP Rating 84

Timóleon Total Indoor Environment with timber UFH, Solar & MVHR.

7

Page 10: Timoleon Specifiers Guide

Solar energy can be used for heating. Usually the water collected in spring, autumn and winter is too cool to be used by radiators but using a Timóleon underfloor heating system with intelligent control and storage can double the payback compared to a conventional twin coil cylinder or thermal store.

See our Solar Heating section from page 66

Solar Heating

Buildings are becoming increasingly more air tight making the need for controlled mechanical ventilation important. By using a whole house system with heat recovery the incoming fresh air is pre-heated recovering over 90% of the energy that would otherwise have been lost.

See our Ventilation section from page 60

Whole House Ventilation

Recovers up to 90% of heat lost through mechanical ventilation.

Up to 40% of the heating load can be provided by solar thermal energy.

8

Page 11: Timoleon Specifiers Guide

Total Ind

oo

r Enviro

nment

The most crucial part to the TIE system is the Aura control system that brings together the controls for the heating, domestic hot water and ventilation making the home’s controls easier to install and simpler to use.

See our Controls section from page 54

Aura Control System

Easy-to-use, holistic controls are essential for energy efficiency

and comfort.

Underfloor HeatingUnderfloor heating is the most comfortable form of heating. Timóleon systems use low water temperatures to further increase efficiency and complement the solar system by using warm water collected in spring and autumn and even the winter.

See our Underfloor Heating section from page 12

Using Timóleon low temperature UFH systems can save 30% on heating bills.

9

Page 12: Timoleon Specifiers Guide

12345

Tried.Tested.Trusted.

Page 12.Timóleon underfloor products are designed to be energy efficient, have high heat output and fast warm-up time.

Page 54.Aura is an innovative, stylish and holistic control system.

Page 60.Reduce energy consumption and improve the building’s air quality with whole house ventilation and heat recovery.

Page 66.Using solar thermal with Timóleon UFH.

Page 72.Help & Advice.

Underfloor Heating

Aura Controls

Solar Heating

Ventilation & Heat Recovery

Here to Help

10

Page 13: Timoleon Specifiers Guide

Total Ind

oo

r Enviro

nment

13. UFH - What do you need?14. UFH - How does it work?16. Are all UFH systems the same?18. UFH Systems in Timber Floors19. CFSH & UFH Products20. UFH Product Range & Selector22. Suspended Floor Constructions26. Battened Floor Constructions

54. Aura Control System55. How does it work?56. Easy to use touchscreen controls59. Aura Sensor, Wiring Centre & Aura Thermostat

61. What is MVHR & how does it work?62. About Whole House Ventilation62. Semi-Rigid Duct63. The Heat Recovery Unit64. Features of an MVHR System

66. Introduction to Solar Heating68. How does the System work?69. What makes our system different?70. The SunCylinder & System components

74. RIBA CPD & Training76. Energy efficiency with Tonos78. Getting a quote & placing an order80. System Schematic81. Index to our publications85. Contact us

30. Floating Floor Constructions34. Screeded Floor Constructions38. Raised Access Floor Constructions40. Acoustic Floor Constructions42. Surface Cooling44. Ceilings & Walls Heating46. Underfloor Heating Pipe48. Axios Manifold

FAQs:50. Floor Finishes51. Concrete Screeds52. Performance, design & guarantees

11

Page 14: Timoleon Specifiers Guide

Many people want underfloor heating simply because it is the most comfortable form of heating, completely unobtrusive, safer and more hygienic than other forms of heating.

We understand this and part of our mission is to ensure that we supply the easiest and quickest to install, best-value underfloor heating, to suit every form of floor construction used in the UK including all forms of timber floor, and for room-by-room refurbishment projects as well as new-build.

But we go much further.

Our underfloor heating products have also been designed (and extensively tested) to absolutely minimise the amount of energy a building’s heating system requires in order to provide effective heating, and to make it realistic for this energy to come from renewable sources either straight away or at some stage in the future life of the building.

Two crucial aspects to the design of our products make this possible. The first is our products minimise the temperature of the heating system water required in order to provide effective heating. The lower this water temperature can be, the more efficiently a boiler can run and the more likely it is that water at this temperature can come from a truly renewable source.

Timóleon underfloor products are designed to be energy efficient, have high heat output and fast warm-up time.

Radiator heating systems and even some poorer forms of underfloor heating must be supplied with high-temperature (55-85˚C) water. This makes such buildings dependent on having a gas or oil boiler because a boiler is the only reliable way of producing water this hot.

All our underfloor heating products are effective using much cooler water (32-55˚C) which not only enables a gas or oil boiler to run much more efficiently but also maximises utilisation of water heated by renewable energy.

The second is the speed with which our products respond to changes in heating power demand. High thermal mass, pipe-in-screed underfloor heating cannot respond quickly to demand-changes, and can waste energy as a result.

Timóleon products have been designed with low thermal mass and this enables them to respond very quickly and efficiently to changes in heating demand.

Are All Underfloor Heating Systems The Same?

TI 9011

12

Page 15: Timoleon Specifiers Guide

Und

erflo

or H

eating

The emitter consists of pipe set within either a screed or timber floor. It should provide effective heating when covered with commonly-used floor finishes, while using low water temperatures. It should be designed to be effective at transferring energy between the pipe and the floor surface.

Good controls are essential for any heating system. Room temperatures should remain comfortable and the heating system should only be on when needed. Underfloor heating systems do not use thermostatic radiator valves so all temperature control is done by thermostats situated within each room. Using thermostats improves efficiency and comfort conditions.

The manifold distributes water from the primary heating system into the individual underfloor heating circuits. For ease of installation the manifold is best positioned in a central location. Manifolds may be fitted with a water mixing valve and secondary circulator wherever high temperature primary water needs to be reduced to the low water temperature needed by an underfloor heating system.

This supplies the warm water needed. It could be a boiler or any of the renewable energy alternatives. The higher the water temperature required by the emitter, the lower its efficiency will be.

1. The Emitter 3. Controls

2. The Manifold4. Heat source

What do you need?

Timóleon LowBoard is the ideal low build-up underfloor heating system for existing floors.

For more information see page 31.

LowBoard in Floating Floors

13

Page 16: Timoleon Specifiers Guide

Underfloor heating works by circulating warm water through pipe embedded within the floor construction. Heat from the pipe is transferred into the floor and then into the room providing enough warmth to heat the building all year round. This removes the need for radiators making more effective use of the space as well as eliminating any high temperature surfaces - an underfloor heating system generally has a surface temperature between 25°C and 27°C, lower than the palm of your hand. A conventional radiator can be as hot as 75˚C.

How does an underfloor heating system work?

The way in which underfloor heating transfers heat is also different to a radiator. Radiators transfer energy principally by convection, heating the air above and around the radiator causing the air to rise. As the warmed air is more buoyant than the cooler air in the room it will rise to the ceiling. The warmed air, as it crosses the ceiling, will begin to cool and then fall. This motion creates a convective current with higher air temperatures nearer the ceiling than the floor.

An underfloor heating system predominantly transfers radiant energy. Compared to radiators, a room with underfloor heating will have a higher radiant temperature with less temperature stratification, draughts and dust movements. This is why underfloor heating is considered the most comfortable form of heating.

Ideal heating curve

RadiatorSystem

Underfloor Heating System

16˚C 16˚C 16˚C20˚C 20˚C 20˚C24˚C 24˚C 24˚C

14

Page 17: Timoleon Specifiers Guide

Und

erflo

or H

eating

Our systems are designed to work with the latest renewable energy technologies.

It is important that any heating system should be designed with the future in mind. If you install a heating system that depends on high water temperatures it is impractical to change in the future to a heat source such as a heat pump or solar cylinder which provides water at low temperatures.

Every heating system should now be designed to enable the homeowner to retrofit renewable technologies in the future. This means designing the system for the lowest possible water temperature.

Designed to be future proof.

BSRIA tests verify you can reduce your energy use with our underfloor heating systems.

At Timóleon we can draw on years of experience to deliver systems for the most challenging of installations. We know that the design and implementation of the underfloor heating is key to an efficient, energy saving and reliable system. We design all of our systems to deliver the best possible performance no matter what type of construction or building.

Our products are independently tested at BSRIA for heat output. This enables us to accurately compare the output of the underfloor heating system with the heat losses of the building to ensure that the system will work as specified.

With any heating system the larger the area of the emitter the cooler the surface temperature needs to be to achieve the same heating effect. This is why underfloor heating runs at a much lower water temperature compared to radiator systems. The use of lower water temperatures better utilises the condensing mode in boilers and allows heat pumps to have a greater efficiency. Studies have demonstrated that using underfloor heating rather than radiators with a ground source heat pump can make the heating system up to 30% more efficient.

Timóleon systems have been independently tested for performance.

15

Page 18: Timoleon Specifiers Guide

4733kWh

Annual EnergyConsumption:

Oversized Radiators

55˚C

4733kWh

Annual EnergyConsumption:

Competitor Air-Gap UFH

55˚C

INS

ULATIO

N

AIR

GA

P

SU

BFLO

OR

BATTE

N

COMPETITOR

COMPETITOR

4115kWh

Annual EnergyConsumption:

49˚C

COMPETITOR

Competitor Rigid Aluminiumheat diffusers

SU

BFLO

OR

INS

ULATIO

N

RIG

ID A

LUM

IN.

BATTE

N

Are all underfloor heating systems the same?If a heating system has to run at high water temperatures the heat source will be less efficient.

Watertemperature:

Watertemperature:

Watertemperature:

16

Page 19: Timoleon Specifiers Guide

Und

erflo

or H

eating

All Timóleon products are designed to use low water temperatures - saving energy and money.

3789kWh

Annual EnergyConsumption:

490kg CO2 saved per year with Timóleon FoilBoard

730kg of CO2 saved per year with Timóleon ToronFloor

46˚CTimóleon Foilboard

FOILB

OA

RD

SU

BFLO

OR

BATTE

N

3329kWh

Annual EnergyConsumption:

41˚CTimóleon ToronFloor

INS

ULATIO

N

SU

BFLO

OR

BATTE

N

The water temperature stated is that needed to provide the same heat output from each system.

Consumption based on a new build 4 bedroom 200m2 property using a ground source heat pump and heating system as shown.

Our products are perfectly suited to using heat pumps and other renewable energy sources. To be able to work with these technologies a heating system must be able to run at low water temperatures yet still provide sufficient heating to warm the building particularly in timber floors. This is important because a heat pump producing lower temperature water will reduce running costs and carbon emissions.

To ensure good performance at low water temperatures it is crucial that there is a conductive pathway that transfers heat quickly from the pipe to the floor surface. If there is a break in the conductive pathway i.e. an air gap, then the efficiency of this energy transfer is greatly reduced. To overcome this inefficiency the water used in the heating system needs to be much hotter to produce an effective heat output.

Independent tests at BSRIA showed that systems that have an air gap between the pipe and floor deck are less efficient at transferring energy than Timóleon systems. This means they have to use significantly warmer water to produce the same heat output.

22mm

ToronFloor

490kgsaved

730kgsaved

The 730kg of CO2 saved per year with Timóleon ToronFloor is equivalent to driving 5,000 miles in a family car.

Did you know?

Watertemperature:

Watertemperature:

17

Page 20: Timoleon Specifiers Guide

SAP, used to determine the energy rating for Building Regulations, recognises that underfloor heating is energy efficient.

Using underfloor heating with a heat pump improves the SAP rating when compared to using a heat pump with radiators. If underfloor heating is installed within a timber “dry” floor the rating is improved even further as it has a faster warm-up time than an in-screed underfloor heating system.

We always strive to meet individual customer’s needs which is why when standard products don’t dovetail with customer’s requirements we're able to provide bespoke solutions.

We can design and manufacture products to suit the building construction, taking into consideration any acoustic details, loading requirements, services and floor fixtures.

Get the best SAP result with timber underfloor heating.

Bespoke products forindividual projects

Using Timóleon timber underfloor heating systems improvesthe SAP rating.

We make sure our systems work well in every construction, including timber floors.

We draw on years of experience to develop and manufacture systems that are easily installed into timber constructions such as suspended, batten or floating floors.

However getting underfloor heating to work effectively in timber floors is not straightforward. Timber is not naturally a good conductor of heat. This means, for certain types of underfloor heating, using high temperature water is the only way the system will be able to heat the room effectively and as a result the efficiency of the heat pump or boiler will be reduced.

We are specialists in manufacturing UFH products for timber floors and have developed a range that works well at low water temperatures. Our systems are also designed to avoid squeaks and ticking and to maintain or improve the strength and acoustic qualities of the floor.

The calculations were based on a new build 100m2 timber frame house using a heat pump.

SAP Rating 77

Using Timóleon ToronFloor or LowBoard throughout the property

SAP Rating 81

Improve SAP ratings considerably by using ToronFloor and LowBoard.

18

Page 21: Timoleon Specifiers Guide

Und

erflo

or H

eating

The BRE green guide is used to rate the construction dependent on the embodied energy of the materials used. This score is used in Code for Sustainable Homes assessments (domestic) and BREEAM (commercial). Below are examples of the ratings given to constructions in which Timóleon underfloor heating products are used. The Global warming Potential (GWP) of the insulation is based on a scale which promotes insulation having a GWPless than 5.

Code for Sustainable Homes (CFSH) and Timóleon UFH products

MIS3005 provides guidance for calculating the efficiency of the heating system. There are several options for the type of emitter used with the heat source which in turn determines the efficiency of the system. For example, using a screed underfloor heating system with a heat output of 50-80 W/m2 and a flow water temperature of 35˚C provided by a ground source heat pump scores the maximum 6 star rating. By comparison a radiator system using a flow water of 45˚C with a ground source heat pump scores only 4 stars as the higher flow temperature reduces the heat pump efficiency.

UFH and Micro-generation Certification Scheme (MCS) Calculations

*These products can be used in a timber construction increasing the CFSH credits awarded.

All Timóleon insulation based products have a GWP of less than 5 and will achieve the maximum credits for CFSH and BREEAM scoring for the construction element (pollution sections). Timóleon is able to provide full CFSH assessment through its Energy Consultancy service, Tonos.

Timóleon Product

ToronFloor OgeeBoard ToronFloor* FoilBoard*FoilBoard

ECOStaple Sys-

temInterDeck AB Plate

Construction type

Suspended SolidBatten over a concrete floor

Floating or Batten over a concrete floor

Suspended/ Batten

Solid concrete Suspended Batten

Material 16mm Ply

overboardScreed 1200

Timóleon ToronFloor 22mm FSC Chipboard

22mm FSC Chipboard

22mm FSC Chipboard

Screed 120022mm FSC Chipboard

Timóleon AB Plate over acoustic battens

Material 2

Timóleon ToronFloor 22mm FSC Chipboard

Timóleon OgeeBoard

manufactured from Knauf Ecoboard

SW battens

Timóleon FoilBoard

manufactured from Knauf Ecoboard

Timóleon FoilBoard

ECO between joists

Timóleon Staples Knauf

Ecoboard

Timóleon InterDeck

22mm FSC Chipboard

Material 3TJI joist / SW

JoistsDPM DPM DPM

TJI joist / SW Joists

DPMTJI joist / SW

JoistsTJI joist

Material 4100mm

RockwoolBison hollow planked floor

Bison hollow planked floor

Bison hollow planked floor

100mm Rockwool

Bison hollow planked floor

100mm Rockwool

100mm Rockwool

Material 513mm

skimmed plasterboard

- - -13mm

skimmed plasterboard

-13mm

skimmed plasterboard

13mm skimmed

plasterboard

BRE Green Guide rating

A + C C C A+ C A+ A+

CFSH credits (HAT 1)

3 0.5 0.5 0.5 3 0.5 3 3

GWP (insulation only)

< 5 < 5 N/A < 5 < 5 < 5 < 5 < 5

GWP Credits (POL 1)

1 1 N/A 1 1 1 1 1

The ToronFloor system is a structural floor panel and underfloor heating system in one. Made from chipboard or plywood, the ToronFloor system is designed to be very effective with heat pumps.

For more information see page 23.

ToronFloor in Suspended Floors

19

Page 22: Timoleon Specifiers Guide

For more detailed information on the products shown in this guide please refer to the technical publications that can be found in our online technical index atwww.timoleon.co.uk.

Each publication can be downloaded directly from our website, e.g. www.timoleon.co.uk/tx101.pdf

For reference, a detailed index of all our currently available publications is shown on page 81 of this guide.

A batten floor is a conventional way of installing a timber floor over a solid subfloor. This type of construction is frequently used in concrete and suspended separating floors to reduce the transfer of sound. The underfloor heating system within the batten space must be in contact with the floor deck to provide good thermal performance.

A floating floor consists of a floor deck supported on a continuous layer, usually insulation, that is not fixed directly to the subfloor. With any floating floor it is important to use insulation that has the appropriate compressive strength for the intended floor loads.

The use of underfloor heating in screeds is common place. Consideration should be given to moisture content and drying times. It is important that the underfloor heating system is not used to dry the screed.

A raised access floor is used to create a space under the floor so that other services can be easily routed through the building. With this type of construction the underfloor heating must be in direct contact with the raised floor to ensure good performance.

The manifold distributes hot water from the boiler or heat pump into each underfloor heating circuit. The pipe used in the underfloor heating circuit must be resilient, durable and easy to install.

In a separating floor there is a requirement to use a construction that reduces the transfer of sound. There are standard constructions referred to as Robust Details which, when followed exactly, ensure compliance with Part E of the Building Regulations. Our underfloor heating systems can be used as part of Robust Detail constructions.

Timber suspended floors use joists to support the floor deck. The underfloor heating system can either sit between the joists or within the floor deck itself. If an acoustic treatment is laid over the suspended floor then an underfloor heating system for a batten or floating floor should be used.

Suspended Floors Pages 22-25

Battened Floors Pages 26-29

Floating Floors Pages 30-33

Screeded & Concrete Floors Pages 34-37

Raised Access Floors Pages 38-39

Manifold & Pipe Pages 46-49

Acoustic & Resilient Floors Pages 40-41

Underfloor Heating Product Range

20

Page 23: Timoleon Specifiers Guide

Und

erflo

or H

eating

Und

erflo

or H

eatin

g

Pro

duct

Sel

ecto

rTIMBER BATTEN

(PAGES 26-29)

TIMBER SUSPENDED

(PAGES 22-25)

LOW BUILD UP(PAGE 31)

TIMBER FLOATING

(PAGES 30-33)

CONCRETE SCREED

(PAGES 34-37)

CEILINGS & WALLS

(PAGE 44-45)

RAISED ACCESS FLOOR

(PAGE 38-39)

DE

SC

RIP

TIO

N

TOR

ON

FLO

OR

AB

PLA

TE

FOIL

BO

AR

D E

CO

FOIL

BO

AR

D

INTE

RD

EC

K

FOIL

BO

AR

D M

OD

ULA

R

LOW

BO

AR

D

OG

EE

BO

AR

D

CLI

PP

LATE

STA

PLE

RA

F P

LATE

ACOUSTIC BATTEN

(PAGE 29)

ACOUSTIC FLOATING

(PAGE 33)

CONCRETE ACOUSTIC

(PAGES 41)

Str

uctu

ral fl

oor

dec

k an

d h

eatin

g sy

stem

in o

ne

Des

igne

d f

or a

cous

tic a

nd s

pru

ng b

atte

n flo

ors

to e

nsur

e co

mp

lianc

e w

ith P

art

E

Inte

grat

ed w

ood

fib

re in

sula

tion

for

imp

rove

d

acou

stic

per

form

ance

on

sep

arat

ing

floor

s

Inte

grat

ed in

sula

tion

for

imp

rove

d t

herm

al

per

form

ance

in t

imb

er fl

oors

For

inst

alla

tion

of t

he U

FH f

rom

bel

ow w

hen

the

floor

dec

k is

alre

ady

in p

lace

Mod

ular

sys

tem

for

cei

lings

and

su

spen

ded

floo

rs

Insu

latio

n w

ith r

oute

d c

hann

els

to

hold

and

pro

tect

the

pip

e

Use

d in

con

stru

ctio

ns a

nd in

floo

rs w

here

th

ere

is n

o in

sula

tion

to fi

x th

e p

ipe

to

Pip

e fix

ed u

sing

sta

ple

s to

th

e in

sula

tion

Fixe

d t

o th

e p

edes

tal i

n a

rais

ed a

cces

s flo

or t

o cr

eate

an

und

erflo

or h

eatin

g sy

stem

13m

m t

hin

pan

els

enab

le U

FH t

o b

e us

ed in

ve

ry lo

w b

uild

up

con

stru

ctio

ns

21

Page 24: Timoleon Specifiers Guide

ToronFloor

FoilBoard Suspended

InterDeck

Structural floor & heating system in one.

Integrated insulation & heating panel for suspended floors.

For continuous pipe installed from the floor below.

Timber suspended floors use joists to support the floor deck. The underfloor heating system can either sit between the joists or within the floor deck itself. If an acoustic treatment is laid over the suspended floor then an underfloor heating system for a batten or floating floor would be more suitable.

Suspended Floor Constructions

There are three systems available from Timóleon for suspended floors:

22

Page 25: Timoleon Specifiers Guide

Und

erflo

or H

eating

INSULATION

FOIL DIFFUSER

JOIST

TORONFLOOR

6mm PLY OR SRB

ToronFloor

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1011

TI 5009

MOBILE

Resources

Suitable for: Panel thickness 22mm(+6mm covering)

18.9kg/m2

(including 6mm)Weight

All suspended timber floors.

12mm PE-RT PIPE

ToronFloor panels are manufactured from flooring grade chipboard or plywood. The pre-machined panels are routed with a unique pattern to accept 12mm pipe. The design of the panel makes it suitable as a structural floor deck.

The panels are laid and fixed onto the joists in the same way as a normal chipboard floor. The pipe is installed into the grooves with the ends of the circuit dropping into the joist space to then continue to the manifold. Once the foil diffuser is fitted a standard overboard layer, such as 6mm ply, is fully glued on top to complete the floor.

As the pipe is embedded within the surface of the floor deck there is an excellent transfer of heat. This provides a high output even at low water temperatures making the system ideal for use with heat pumps and other renewable energy sources.

The ToronFloor heating system has been independently tested at TRADA for structural performance.

Structural floor & heating system in one.

23

Page 26: Timoleon Specifiers Guide

FoilBoard Suspended is an insulated underfloor heating panel installed between the joists of a suspended floor. To hold the panels in place brackets (or battens) are installed within the joist space to ensure that the system is in direct contact with the floor deck. This ensures an excellent transfer of heat from pipe to the deck.

The panels are manufactured from XPS insulation with a pre-bonded soft temper aluminium heat diffuser, making the panel easy to trim on site. Once brackets or support battens are installed the panels drop into place in exactly the right position.

FoilBoard suspended is available in 50mm & 75mm thicknesses. It is also available in FSC approved recyclable wood fibre board and has good thermal, acoustic and fire retardant properties.

16mm PE-RT PIPE

JOIST

OPTIONAL BRACKETS

FOILBOARD

FoilBoard Suspended

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1007

TI 5005

MOBILE

Resources

Suitable for:Suspended Floors.

Integrated insulation & heating panel for suspended floors.

Panel thickness 50mm or 75mm

0.033 w/m2KInsulation conductivity

30 kg/m3Material density

24

Page 27: Timoleon Specifiers Guide

Und

erflo

or H

eating

12mm PE-RT PIPE

JOIST

INSULATION

INTERDECK

InterDeck

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1017

TI 5016

MOBILE

Resources

Suitable for:Suspended upper floors where the floor deck is already in place.

The InterDeck system is used in a suspended floor when the floor deck is already in place. The InterDeck panels are manufactured with an integral heat diffuser so that they can be fixed to the underside of the floor deck.

Once the panels are in place the pipe is inserted into the pre-routed channels either as a continuous length or by forming small circuits within each joist space connected to a common flow and return. Insulation quilt is then installed directly beneath the panels within the joist space.

InterDeck panels are available for 400mm centre joists (3 pipe channels) or 600mm centre joists (4 pipe channels) but can be easily trimmed to fit other joist centres.

Installed from the floor below.

Panel thickness 16mm

3.8 kg/m2Weight:

25

Page 28: Timoleon Specifiers Guide

ToronFloor

FoilBoard Batten

AB Plate

Structural floor & heating system in one.

Rapid installation with integrated insulation & heat diffuser.

Heat diffuser plates designed for acoustic battens.

A batten floor is a conventional way of installing a timber floor over a solid subfloor or when the ultimate floor deck is to be hardwood planks which must be fixed using nails or screws. This type of construction is frequently used in concrete and suspended separating floors to reduce the transfer of sound. Any underfloor heating system within the batten space must be in firm contact with the underside of the floor deck to provide good thermal transfer.

Batten Floor Constructions

There are three systems available from Timóleon for batten floors:

26

Page 29: Timoleon Specifiers Guide

Und

erflo

or H

eating

INSULATION

FOIL DIFFUSER

BATTEN

TORONFLOOR

12mm PE-RT PIPE

6mm PLY OR SRB

ToronFloor

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1010

TI 5010

MOBILE

Resources

Suitable for:Timber batten floors.

ToronFloor panels are manufactured from flooring grade chipboard or plywood. The pre-machined panels are routed with a unique pattern to accept 12mm pipe. The design of the panel makes it suitable as a structural floor deck.

The panels are laid and fixed onto the battens in the same way as a normal chipboard floor. The pipe is installed into the grooves with the ends of the circuit dropping into the batten space to then continue to the manifold. Once the foil diffuser is fitted a standard overboard layer, such as 6mm ply, is fully glued on top to complete the floor.

As the pipe is embedded within the surface of the floor deck there is an excellent transfer of heat. This provides a high output even at low water temperatures making the system ideal for use with heat pumps and other renewable energy sources.

The ToronFloor heating system has been independently tested at TRADA for structural performance.

Structural floor & heating system in one.

Panel thickness 22mm(+6mm covering)

18.9kg/m2

(including 6mm)Weight

27

Page 30: Timoleon Specifiers Guide

CONCRETE SUBFLOOR

16mm PE-RT PIPE

BATTEN

FOILBOARD

FoilBoard Batten

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1004

TI 5003

MOBILE

Resources

Suitable for:Conventional batten floors.

The Timóleon FoilBoard system can be laid between timber battens. The FoilBoard panels are manufactured from XPS insulation with pre-bonded soft temper aluminium heat diffusers. As no thick rigid plates are used the panels can be easily trimmed on site.

The panels are designed so that when a floor deck is laid over and fixed to the battens it will be in direct contact with the FoilBoard panels, ensuring good thermal transfer. This increases performance considerably compared to systems that rely on rigid diffuser plates, and reduces the risk of creating squeaky floors.

The standard product is available in any thickness from 25mm and for a variety of batten centres.

Faster install with integrated insulation & heat diffuser.

Panel thickness 25mm, 35mm, 50mm or 75mm

0.033 w/m2KInsulation conductivity

30 kg/m3Material density

28

Page 31: Timoleon Specifiers Guide

Und

erflo

or H

eating

16mm PE-RT PIPE

GYPSUM BASED BOARD

AB PLATE

ACOUSTIC BATTEN

AB Plate

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1012

TI 5006

MOBILE

Resources

Suitable for:Acoustic batten floors

The AB Plate system is installed in batten floors used in conjunction with acoustic or resilient floor constructions. The AB Plates are pre-formed diffuser plates with integrated insulation improving the transfer of heat into the floor deck. The “wings” of the module are angled slightly upwards so that when the floor deck is laid there is guaranteed contact between the floor and plate. This is crucial to ensure good performance from the underfloor heating system.

Each AB Plate is fixed over a resilient batten leaving a gap between each plate for the installer to walk. The system complies with the requirements of an underfloor heating system used in a batten floating floor treatment for a Robust Detail construction. Please see our guide to Underfloor Heating with Acoustic floors, TX100, for more information.

Heat diffuser plates designed for acoustic battens.

Weight 8.3 kg/m2

29

Page 32: Timoleon Specifiers Guide

LowBoard

FoilBoard Floating

FoilBoard SRB

Low build-up underfloor heating system for existing floors.

Integrated diffuser & insulation for a fully floating floor.

A low build-up floating floor system with improved acoustic performance.

A floating floor consists of a floor deck supported on a continuous layer, usually insulation, that is not directly fixed to the subfloor. With any floating floor it is important to use insulation that has the appropriate compressive strength for the intended floor loads.

Floating Floor Constructions

There are three systems available from Timóleon for floating floors:

30

Page 33: Timoleon Specifiers Guide

Und

erflo

or H

eating

BONDED HEAT DIFFUSER

OPTIONAL FOAM UNDERLAY

LOWBOARD PANEL

12mm PE-RT PIPE

6mm PLYWOOD OR SRB

LowBoard

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1015

TI 5014

MOBILE

Resources

Suitable for:Low build-up where floor height is restricted. Particularly suitable for refurbishments.

The LowBoard panel enables underfloor heating to be installed where there is minimal height available to build up the floor. The total height of the panel is just 13mm.

The LowBoard panel is a high density wood board with grooves routed to accept the 12mm pipe. The panel has an aluminium layer bonded to the underside that acts to spread the heat through the board and into the floor. The panels are laid as a floating floor over the existing construction with a ply layer or the floor finish laid over to complete the floor.

LowBoard is also available in 22mm thick panels for 16mm pipe. LowBoard 22 is used for larger areas where longer pipe runs are required.

Low build-up underfloor heating system for existing floors.

Panel thickness 13mm or 22mm

11.1kg/m2 (13mm)Weight

31

Page 34: Timoleon Specifiers Guide

CONCRETE SUBFLOOR

16mm PE-RT PIPE

FOILBOARD

FoilBoard Floating

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1005

TI 5004

MOBILE

Resources

Suitable for:Conventional fully floating floors with continuous insulation.

The FoilBoard Floating system is laid over a solid floor. The panels provide the support for the fully floating tongue and groove floor deck that is laid over. Each panel is manufactured from XPS insulation which has a high compressive strength, suitable for floating floor applications.

The heat diffusers are pre-bonded and made from soft temper aluminium. As no thick rigid plates are used the panels are easily trimmed on site.

Once the insulation is laid a tongue and groove floor deck is laid over. The product is available in any thickness from 25mm.

Integrated diffuser & insulation for a fully floating floor.

Panel thickness 25mm, 35mm 50mm

0.033 w/m2KInsulation conductivity

200 kPaCompressive strength

30 kg/m3Material density

32

Page 35: Timoleon Specifiers Guide

Und

erflo

or H

eating

16mm PE-RT PIPE

INSULATION

FOILBOARD ECO

SCREED REPLACEMENT BOARD 23

FLOORDECK

FoilBoard SRB

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1013

TI 5004

MOBILE

Resources

Suitable for:Separating floors where there is a requirement for improved acoustic insulation.

The FoilBoard SRB system has two components, the floating floor panel and the Screed Replacement Board (SRB) overlay. The 35mm floating floor panel is manufactured from FSC approved wood fibre insulation. This has channels to accept 16mm pipe and is pre-bonded with a soft temper aluminium diffuser. The SRB is laid over to complete the fully floating floor.

The FoilBoard panels and SRBs improve the acoustic performance of the floor. The SRB is more conductive than conventional chipboard flooring further improving the heat output making the FoilBoard SRB system suitable for use with heat pumps and other sources of renewable energy.

A floating floor system with improved acoustic performance.

Panel thickness 35mm (+23mm SRB)

0.039 w/m2KInsulation conductivity

50 kPaCompressive strength

37.5 kg/m2

(Including23mm SRB)

Material density

33

Page 36: Timoleon Specifiers Guide

OgeeBoard

ClipPlate

Staple

Underfloor heating panels that replace the floor insulation.

Installation without fixings or staples.

For fixing pipe to insulation.

The use of screeds in underfloor heating systems is common place. The screed that surrounds the pipe is a good conductor of heat making the system very efficient in transferring energy from the pipe to the floor surface. In many ways a heated screed can be treated in the same way as an unheated screed however consideration must be given to the initial warm up procedure and to expansion.

Screeded & Concrete Slab Constructions

There are three systems available from Timóleon for screeded floors:

34

Page 37: Timoleon Specifiers Guide

Und

erflo

or H

eating

VAPOUR CONTROL LAYER

OGEEBOARD

16mm PE-RT PIPE

CONCRETE SCREED

OgeeBoard

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1016

TI 5015

MOBILE

Resources

Suitable for:Conventional screed floors replacing, or adding to, the specified insulation.

OgeeBoard is manufactured from XPS polystyrene insulation and can replace the insulation needed to comply with building regulations. The polystyrene boards are routed with channels into which the pipe is installed. With the pipe installed a screed is laid over.

The OgeeBoard insulation panels are designed to hold the pipe within the thickness of the insulation reducing the possibility of damage from site traffic. No other fixings, staples or plates are needed to hold the underfloor heating pipe in place. The OgeeBoard insulation panels are available in any thickness from 35mm enabling very fast installation of the screed underfloor heating, with assured pipe centres.

Underfloor heating panels that replace the floor insulation.

Panel thickness 35mm, 50mm or 75mm

0.033 w/m2KInsulation conductivity

30 kg/m3Material density

35

Page 38: Timoleon Specifiers Guide

CLIPPLATE*

STRUCTURAL FLOOR

SCREED

16mm PE-RT PIPE

*With integrated insulationClipPlate

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1003

TI 5002

MOBILE

Resources

Suitable for:Acoustic constructions and floors where there is no insulation to fix the pipe to.

The ClipPlate system has been purposely designed to avoid using fixings and staples in the floor.

ClipPlate consists of a series of interlocking sheets with an integrated 10mm expanded polystyrene insulation layer. The castellations in the panel provide grip for the pipe, whilst also providing protection from site traffic and the screed being laid.

The ClipPlate panels can be installed over any subfloor. Where floor build-up is limited the integrated 10mm EPS provides some resistance when the product is laid over an uninsulated floor. The panel is designed to allow pipes to be installed at centres as close as 50mm and at 45° & 90° bends, providing additional flexibility.

Installation without fixings or staples.

Panel thickness 29mm

0.038 w/m2KInsulation conductivity

1.1 kg/m2Weight

36

Page 39: Timoleon Specifiers Guide

Und

erflo

or H

eating

OPTIONAL GRIDDED INSULATION

SUBFLOOR

SCREED

16mm PE-RT PIPE

VAPOUR CONTROL LAYER

Staple

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1001

TI 5001

MOBILE

Resources

Suitable for:Conventional screed floors where insulation is present.

The staple system provides a quick, flexible and simple method of installing underfloor heating into a screeded floor.

The pipe is easily held using staples. The staples have a barbed end which fixes into the insulation. The Timóleon Gridded insulation has a laminated foil surface that provides an even stronger fix than plain insulation alone. The foil also provides a convenient grid guide that can easily help with the layout of the pipe circuits.

For fixing pipe to insulation.

37

Page 40: Timoleon Specifiers Guide

RAF Plate

The Timóleon RAF system is installed over the pedestal to heat the floor deck.

A raised access floor has a floor deck supported on pedestals that can be removed to provide access for services.This type of floor is usually used in commercial applications. The floor deck is supported on pedestals set to the required height with the pedestals set at centres suitable for the floor loadings.

Raised Access Floor Constructions

There is one system available from Timóleon for Raised Access floors:

38

Page 41: Timoleon Specifiers Guide

Und

erflo

or H

eating

RAF PLATE

SUBFLOOR

16mm PE-RT PIPE

RAF Plate

DATASHEET & SPECIFICATION

INSTALL GUIDE

Scan here for downloadable mobile version of the specification.

TI 1018

TI 5018

MOBILE

Resources

Suitable for:Raised access floors with pedestals.

The RAF plates are designed to fit over pedestals used in a raised access floor construction. The plates comprise of a formed diffuser plate with pre-bonded insulation. The RAF plates are designed not to droop or sag, the diffusers are manufactured with a slight upward angle so that when the floor is installed there will be good heat transfer into the floor deck. The plates fix directly to the pedestal heads so there is no requirement for any brackets or separate fixings. The diffusers have a preformed channel for the 16mm pipe and insulation pre-bonded to the underside to ensure good upward transmission of heat. With the plates in place there is space between the panels to be able to access any of the services.

Straightforward installation into a raised access floor.

5.1 kg/m2Weight

39

Page 42: Timoleon Specifiers Guide

Timóleon underfloor heating systems are ideally suited for incorporation into acoustic constructions, both in residential and commercial applications. Part E of the Building Regulations shows how such constructions must provide resistance to the passage of sound. Compliance with the performance standards is demonstrated by passing a pre-completion test (PCT) for each individual construction. However PCTs can be avoided if a Robust Standard Detail (RSD) is adopted. Specific RSDs have been established for each construction and underfloor heating can be incorporated into an RSD construction provided:

Ì That no fixings or staples penetrate or break the separating resilient layer used in a construction.

Ì In a floating floor treatment the underfloor heating does not connect the structural floor with any of the floating floor elements thereby bridging the resilient layer.

There are a variety of RSD constructions and it is important to understand how effective the underfloor heating system will be when used with these constructions. In our guide to underfloor heating and acoustic constructions (TX 100) we show how underfloor heating can be simply incorporated.

Acoustic constructions are commonly found in residential buildings with floors, walls and ceilings that separate living spaces. These constructions are required to provide resistance to the passage of sound allowing occupants to enjoy quiet living conditions without being disturbed by those living in adjacent properties. Such buildings can benefit enormously from underfloor heating, not only to enhance the living environment but also to improve energy efficiency.

What is an Acoustic Floor Construction?

TECHNICAL INDEX TX 100

Resources

Acoustic Floor Constructions

ROOM B

Key to diagram

Airborne sound

Impact sound

Travel of sound/ flanking transmission

Sound

Acoustic insulation in a floor is important to reduce the transfer of sound.

40

Page 43: Timoleon Specifiers Guide

Und

erflo

or H

eating

Batten Floors - AB Plate

Floating Floors - FoilBoard SRB

Screeded Floors - ClipPlate

Our acoustic range of products are ideally suited for both residential & commercial applications.

The AB plate is installed directly over the acoustic battens. The product is designed to allow the installer to walk between plates. The AB plates have a pre-bonded insulation layer which improves the thermal transfer into the floor deck.

The FoilBoard ECO system is manufactured from wood fibre insulation and as such improves the acoustic performance of the floor compared to polystyrene insulation. The FoilBoard ECO is used as a floating floor with a Screed Replacement Board laid over.

The ClipPlate system does not require any fixings or staples. This ensures the acoustic layer isn’t punctured when the pipe is being laid. The ClipPlate product also comes with integrated insulation improving the thermal performance.

Batten systems with a resilient layer can be used in timber and concrete suspended floors. These are termed as floating floor treatments. The batten moves up and down due to the resilient layer so it is important the underfloor heating system moves with the batten to maintain contact with the floor deck.

E-FT-5 and E-FT-6 are Robust Detail constructions for floating floors in which underfloor heating can be installed. Floating Floor Treatments FFT4 and FFT5 cannot have underfloor heating installed within the resilient layer.

Underfloor heating systems used within a screed floor must not penetrate the resilient layer (i.e. using fixings such as staples) and must avoid bridging the screed to the slab.

41

Page 44: Timoleon Specifiers Guide

Cool water can be used in the underfloor heating system to provide room cooling as an alternative to air-conditioning. It is also possible to chill the ceiling or wall to get the same effect. This method of cooling is called Surface Cooling.

Surface cooling

Surface cooling is able to provide comfort cooling to most commercial applications with outputs up to 70W/m2 for a ceiling system and 50W/m2 for a floor system. A surface cooling system will reduce the sensible loads in a space. It may be necessary, in humid conditions, to provide dehumidification. Dehumidifying a space also has the benefit of reducing the dew point (which limits surface temperature and therefore output) and increasing the cooling capability of the system.

Chilled water is provided by either a ground source or air source heat pump. A surface cooling system requires water at a higher temperature than that needed by an air conditioning system. This increases the efficiency of the air source heat pump. Where ground loops are installed the benefits are even greater. During the summer the ground temperature will be around 15°C at a depth of 2 metres. When coupled with a heat exchanger this chilled water can be used directly in the surface cooling system, making it almost free to run, with the benefit of recharging the ground, storing the unwanted heat energy until needed by the heat pump.

Performance

Cool, not cold

A low energy alternative to air conditioning.

TECHNICAL INDEX TX 111

Resources

Our FoilBoard Ceiling system can be used in suspended grid ceiling applications in newly built and existing buildings. It is particularly suited to use in retrofit commercial applications.

The system is modified by having pipe pre-installed into the panel. The modular panel is then installed above a standard 600mm x 600mm ceiling tile.

Once the panels are in place the tails of each module are connected in series to create an underfloor heating circuit.

42

Page 45: Timoleon Specifiers Guide

Und

erflo

or H

eating

Air conditioning is responsible for 10% of the energy used in commercial buildings. Using surface cooling can significantly reduce energy consumption whilst provide a comfortable working environment.

The transfer of energy in a surface cooling system is mostly done by radiant heat exchange, approximately 80%. The absorbing surface, a floor, wall or ceiling is cooled to a temperature lower than the items and occupants within a room. This cooled surface will then absorb energy from within the room. In reducing the radiant temperature the occupants feel more comfortable even though the air temperature has only slightly changed. This effect is analogous to a church or cave where the walls and floor are at a lower temperature than the air making the space feel cooler. Air conditioning works in a different way, mechanically forcing air over cooling elements thereby cooling the air in the room but not significantly reducing the radiant temperature. This results in extremes of radiant and air temperature being created. Big differences between air and radiant temperature creates discomfort, experienced by anyone who sits near both a south facing window and an air-conditioning unit on a hot summer’s day. Surface cooling creates an environment where the air and radiant temperatures are closer together which, with the absence of noise and air movement from an air conditioning unit makes for a more comfortable working environment.

Surface cooling vs air-conditioning

Creating comfortable working environments that save on energy usage when compared with air conditioning.

43

Page 46: Timoleon Specifiers Guide

Ceilings & walls

The same principle that makes underfloor heating work can be applied to walls and ceilings. As long as there is sufficient heating area a room can be satisfactorily warmed with a ceiling or wall heating system giving the same comfortable radiant effect as underfloor heating.

The heat output of ceiling and wall systems tend not to be restricted by floor finishes in the same way as an underfloor heating system and can therefore work at even lower water temperatures with the resulting surface temperature being around 30˚C.

The temperature profile of a ceiling heating system is very similar to an underfloor heating system and therefore creates similar levels of comfort. The surface temperature of the ceiling system should be no more than 30˚C to avoid temperature asymmetry which could reduce comfort levels.

In comparison a warm air system creates significant temperature stratification with high temperatures near the ceiling and low temperatures near the floor, not only does this feel uncomfortable but is inefficient especially in rooms with high ceilings.

Heating in ceilings and walls

A radiant heating system can be installed in the wall or ceiling.

1. Underfloor Heating

3. Radiator Heating

2. Warm air heating

4. Ceiling Heating

16˚C

16˚C 16˚C

16˚C20˚C

20˚C 20˚C

20˚C24˚C

24˚C 24˚C

24˚C 28˚C

44

Page 47: Timoleon Specifiers Guide

Und

erflo

or H

eating

The FoilBoard panels are manufactured from insulation with a pre-bonded aluminium diffuser. The panels are designed to fit between the joists above the ceiling. The panels are easily trimmed to avoid any obstructions and are available in a variety of sizes to suit the construction. Once the panels have been installed the ceiling will be in direct contact with the heating surface improving performance. The panels are either pre-piped as modules or can have the pipe installed on-site in a continuous length.

DATASHEET & SPECIFICATION

INSTALL GUIDE

TI 1008

TI 5007

FoilBoard

Scan here for downloadable mobile version of the specification.

MOBILE

Resources

Suitable for:For conventional timber suspended ceilings.

For installation into a suspended ceiling.

PE-RT PIPE

JOIST

FOILBOARD

CEILING

Panel thickness 35mm

0.033 W/m2KInsulation Conductivity

45

Page 48: Timoleon Specifiers Guide

Ì Oxygen-tight with co-extruded EVOH layer in accordance with DIN 4726

Ì Operational range, max. 6 bar, constant temperature 70 °C

Ì Corrosion free Ì Excellent stress crack resistance Ì Suitable for particularly rough laying

conditions due to 5-layer technology Ì Flexible and easy to lay Ì Tight bending radius Ì Resistant to numerous chemicals

(details on request) Ì No incrustation due to smooth inner

pipe wall Ì Low weight

Ì KOMO approval: K14254 Ì SKZ (Southern German Plastics Centre)

monitored (SKZ symbol A236) Ì Properties in accordance with DIN

16833 / 16834

Timóleon uses high quality PE-RT underfloor heating pipes. The five-layer structure achieves a high degree of oxygen tightness and ensures that this is retained even under rough building site conditions. The entire range is backed by decades of experience in plastics processing. A specially modified polyethylene of medium density is used for underfloor heating systems using PE-RT pipe, the molecular structure and composition of which ensures very good thermal stability and a high degree of mechanical strength. The five-layer pipe structure is manufactured by means of extrusion in one single process. The EVOH layer provides a very good oxygen barrier while the outer PE-RT layer protects the entire structure against damage.

Flexible & lightweight Underfloor Heating Pipe from Timóleon.

Our durable & environmentally friendly pipe make it the best choice in today's building trade.

Key advantages of PE-RT pipe Approvals & Standards

PRESSURE TESTING GUIDE

DATASHEET

TI 5012

TI 7002

46

Page 49: Timoleon Specifiers Guide

Und

erflo

or H

eating

Timóleon's high quality PE-RTunderfloor heating pipe

47

Page 50: Timoleon Specifiers Guide

Ì Simple to install Ì “A” rated circulator with pre-wired plug

and lead Ì Auto airvents Ì Mixing valve Ì Patented pipe connections

The manifold distributes the primary warm water into each underfloor heating circuit. The manifold is the central point for the underfloor heating system, bringing together the warm water feed from a heat source (such as a boiler, heat pump or thermal store), the pipe work from the floor and also the thermostat wiring.

A manifold can serve areas up to 200m2 but installation is easier if a manifold is installed in accessible locations on each floor. The size of the manifold depends on the area it is serving.

The Timóleon Axios manifold provides all the functionality stipulated by British Standards (BS1264-4) for an underfloor heating manifold. A mixing valve and circulator can be added to the manifold to reduce the water temperature to that needed by the underfloor heating system. The Axios manifold is available with a pre-assembled mixing valve and “A” rated Grundfos Alpha 2L circulator.

The Axios manifold. Simple installation, reliable performance.

Timóleon Axios Manifold

INSTALL GUIDE

COMMISSIONING & SERVICING

TI 6001

TI 6003

50˚C

40˚CMixingValve

Circulator Underfloorheating flow

Underfloorheating return

75˚C

Flow Return

BoilerPrimaries

Pump & Mixing

Unit2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Port 9 Port

10 Port

11 Port

12 Port

L (mm) 185 180 230 280 330 380 430 480 530 580 630 680

B (mm) 415 365 365 365 365 365 365 365 365 365 365 365

D (mm) 100 90 90 90 90 90 90 90 90 90 90 90

If required, add the dimensions of the pump and mixing unit to the manifold dimensions.

BB

L

D

L

48

Page 51: Timoleon Specifiers Guide

Und

erflo

or H

eating

THE

RM

OS

TATIC M

IXIN

G VA

LVE

MIX

ED

FLOW

WATE

R TE

MP

ER

ATUR

E G

AU

GE

WH

ITE LO

CK

ING

RIN

G W

ITH IS

OLATIN

G VA

LVE

FLOW

ME

TER

WITH

BA

LAN

CIN

G VA

LVE

AC

TUATO

RS

DR

AIN

AN

D FILLIN

G P

OIN

T

AU

TO (G

RE

Y) &

MA

NU

AL (B

LAC

K) A

IRV

EN

T

A-R

ATED

CIR

CU

LATOR

- VAR

IAB

LE &

FIXE

D S

PE

ED

49

Page 52: Timoleon Specifiers Guide

All types of floor finish can be used with underfloor heating providing the resistance of the finish is considered. A highly resistive floor finish will slow the flow of heat into the room. Typical floor finishes such as timber and carpet are regularly used with underfloor heating.

Some finish manufacturers stipulate maximum surface temperatures, underfloor heating will create a floor surface temperature of approximately 26°C for most applications however some systems where the building heat loss is high will have surface temperatures up to 29°C. Underfloor heating systems should not be designed to operate at floor surface temperatures higher than 29°C. If your intended finish is greater than 1.5 Tog then please call us and we will check the performance of the underfloor heating.

It is important to ensure that when laying this product over a concrete subfloor that the subfloor is completely dry otherwise bubbling may occur. The relative humidity of the subfloor should be no more than 75% (measured as specified in BS 8201).

Timóleon has long experience of how good UFH is the best way of caring for a hardwood floor. Timber changes dimension due to changes in its moisture content, and this varies naturally throughout the year. The important issue is to keep the moisture content of the upper and lower surfaces of the timber the same. If they do, the timber floor will stay perfectly flat. If they don’t, it could crown or cup.

The first key is to lay the timber floor with moisture content at 8-10%. The second is to ensure the UFH turns on gradually at the beginning of each heating season, which can be assured by using programmable room thermostats and leaving the heating on. The heating will then run briefly, and only as necessary, allowing time for absorbed moisture to naturally respire into the room.

These materials have a low thermal resistance that makes them very suitable for underfloor heating. Consideration must be given to expansion gaps and the suitability of adhesives used to bond the tiles to the subfloor.

Timber Floors Linoleum & vinyl tiles or sheet

Carpet

Ceramic & Stone

Our general advice is to avoid carpets and underlay having thermal resistance greater than 1.5 Tog. However, tests carried out at BSRIA on 24 different combinations showed that some with higher published resistance than this work well over UFH. Timóleon understands the results of these tests, which measured the difference between Published Tog and Effective Tog, and can advise accordingly.

UFH FAQs:Floor Finishes

The best floor coverings to work with underfloor heating systems are typically those with low thermal resistance.

50

Page 53: Timoleon Specifiers Guide

Und

erflo

or H

eating

BS 8204 part 2 provides details on spacing and positioning of joints within a concrete screed.

The British Standard for underfloor heating, BS 1264 part 4, states that there should be joints in stone and ceramic finished screeds every 40m2, with a maximum length of 8m between joints. A joint must be placed at least every 8m across the floor but as the joint is only one third of the screed thickness it should not interfere with the underfloor heating pipe provided the underfloor heating circuit has been fixed down securely. Only flow and return pipe should pass through movement joints. Where this happens a 300mm piece of conduit should enclose the pipe and span the joint.

Laying screeds in Underfloor Heating

Drying of screeds

There are many different types of screed from the conventional sand/cement screed to proprietary liquid screeds. The screeds that are discussed here are floating screeds i.e. they are not bonded to the concrete subfloor.

Sand/cement screeds – The minimum thickness of a floating screed is 75mm for commercial installations and 65mm for domestic installations. There should be a minimum of 50mm screed over the pipes (BS8204-1).

Calcium sulphate and anhydrite screeds – The benefit of using this type of screed is that the drying time is less than conventional sand/cement screeds and there is less shrinkage. The minimum thickness of a screed in a commercial installation is 40mm and 35mm in a domestic installation. There should be a minimum of 25mm screed over the pipes (BS8204-7).

Pumpable self-smoothing screeds – There are many proprietary screeds on the market. Advice should always be sought from the manufacturer.

As a rule of thumb a 50mm sand/cement screed could be expected to dry in good conditions within 2 months and a 75mm screed around 3 months.

BS 1264-4 states that sand cement screeds should not be heated for at least 21 days after laying and with anhydrite screeds 7 days after laying. The screed manufacturer’s instructions must alwaysbe followed.

Once the screed has dried the system can be turned on but the screed must not get any warmer than 25˚C for the first 3 days or 15˚C above the temperature of the unheated floor.

UFH FAQs:Concrete Screeds

After this period the system can be switched to the maximum temperature and kept there for 4 days. The underfloor heating must never be used to dry the screed.

It is important that the screed must be allowed to cool to room temperature before the final floor finish is laid.

51

Page 54: Timoleon Specifiers Guide

Underfloor heating systems can be designed to react very quickly to heating demands. The warm-up time of the system depends upon several factors.

The time taken for the underfloor heating system to emit heat is dependent on the characteristics of the floor in terms of the construction, pipe centres and the floor finish and also the temperature of the water used in the underfloor heating system. Underfloor heating with pipe embedded in a thick concrete slab will have a longer warm up time than dry construction systems such as those used in suspended, batten or floating floors. This is recognised in SAP with timber floor underfloor heating having a better overall SAP rating than concrete underfloor heating.

The room warm-up time is also dependent on the heat loss of the building. The underfloor heating system must be sized to overcome the heat losses of the building but also have additional capacity to ensure a good response time from cold.

The cost of running an underfloor heating system depends on the heat loss of the house, how often the heating system is running, the cost of the fuel or electricity and the type of heat source. So it is difficult to predict running costs although studies have shown that heating systems using low water temperatures will be the most efficient and have the lowest running costs. Good underfloor heating, as it is a large surface area emitter, will run at the lowest water temperatures.

The underfloor heating heat output is based on a number of variables:

Floor finish - floor finishes have different thermal resistances. Tiles for example are very conductive whilst a combination of carpet and underlay is less conductive. Also, the thicker the material the lower the heat output will be.

Water temperature – the higher the mean water temperature (the average between flow and return temperature) the higher the heat output.

The underfloor heating product and the construction it is put into – Timóleon products are designed to have a strong conductive pathway from pipe to the floor surface. Some competitor's products have an air gap which reduces the heat output.

Timóleon has tested its systems at BSRIA and is able to provide information on the heat output for your specified construction.

Underfloor Heating Performance

Underfloor heating running costs

Underfloor heating heat outputs

Timóleon products are specifically designed to provide the perfect partner for heat pumps and other sources of renewable energy.

UFH FAQs:From performance to design.

52

Page 55: Timoleon Specifiers Guide

Und

erflo

or H

eating

Maintenance of the underfloor heating system is straightforward. There is no specific maintenance required for the heating system other than that needed for the boiler or heat pump. The circulator, actuator valve and mixing valve are the only moving parts and these are designed for continuous operation over many years.

UFH Maintenance

Timóleon has a strict policy of quality control in all aspects of its business from design to product manufacture. We adhere to the British Standards where they apply to the designs, products or systems that Timóleon manufactures and produces. Timóleon systems have been tested for performance with BSRIA and TRADA where appropriate.

Guarantees

For your peace-of-mind our designs, products and systems are backed by £1,000,000 professional indemnity insurance and £5,000,000 product liability insurance.

Insurance

When installing underfloor heating it is important that there is an underfloor heating design showing where the pipe is in the floor, how close the pipe is together and what product is being used as the heat emitter. For simple systems the design can be produced by the installer and does not need to be a formal CAD drawing. However Timóleon provides a full design service for all orders showing where the pipe and product sits in the floor along with the balancing settings for the installer to commission the system.

UFH Design

53

Page 56: Timoleon Specifiers Guide

Introducing the Aura system from Timóleon. Bringing you innovation and style.

Effective controls are essential in creating a comfortable living and working environment. This not only means controlling the temperature in a room but making sure the system runs only when it is needed. To do this the controls not only have to be accurate but easy to use.

The Aura system is flexible, holistic and intuitive to use. It can accurately control the room temperature, program the hot water system and change the ventilation demand through one central touchscreen interface, the ControlPad.

The Aura thermostat is a discreet, attractive fully programmable room thermostat. It can be used on its own or in conjunction with the ControlPad. The Aura sensor provides the same level of room control without the user interface. The sensors can be located discreetly within each room but collectively controlled by the central ControlPad. This makes controlling the system easier, rooms can be switched off as a whole as well as making the room controls tamper-proof.

Aura is an innovative, stylish and holistic control system.

54

Page 57: Timoleon Specifiers Guide

Aura C

ontro

l System

Whether using room thermostats or sensors the ControlPad gives the user a simple way to control all of the heating zones together. One-touch functions are displayed on the ControlPad that make controlling the whole heating system straightforward and intuitive.

Stylish all in one touchscreen allows complete control from one, simple interface.

The ControlPad brings together the multitude of controls present in a modern day home such as the room thermostats, domestic hot water timer and ventilation boost.

The time settings for the hot water system can be set from the ControlPad removing the need for a separate timer.

The whole house ventilation system uses the boost function to quickly bring in fresh air and remove any odours. The ventilation system also has a summer bypass facility that brings in cool fresh air during the summer.

2. Heating

4. ControlPad1. Hot Water

3. Ventilation

Discreet and unobtrusive, sensors are an alternative to thermostats.

With no thermostat in each room the programming for the heating system is done from the ControlPad.

5. Sensors

55

Page 58: Timoleon Specifiers Guide

The home screen has been designed for simple one-touch control of all the shortcuts and boost functions. There are no complicated programs to activate each function. All of the system settings are accessed through one button on the home screen and if you’re in doubt there is an information page on each screen.

The settings for the one-touch buttons on the home page are set up here. The interface has been designed to be intuitive and simple to use yet without compromising on any of the features that a homeowner might need.

This function enables the user to lock or limit certain thermostats so that they can only be adjusted by a set amount. For example, in a school or nursing home the caretaker using this function can set certain thermostats so that they can only be adjusted by, say, 2˚C or locked altogether. This prevents tampering leading to unnecessary heating.

The user can define the temperatures required throughout the day. This is displayed graphically to show when the rooms are scheduled to get warmer. The heating profiles are then applied to each zone. This simplifies programming as the user can simply change the profile rather than changing the settings for each zone on each separate day.

Settings

Home Screen

Zone Lock Heating Program

Straightforward display that is intuitive to use.

Bringing together the home energy controls in a stylish and holistic user interface.

56

Page 59: Timoleon Specifiers Guide

Aura C

ontro

l System

57

Page 60: Timoleon Specifiers Guide

58

Page 61: Timoleon Specifiers Guide

Aura C

ontro

l System

Discreet sensors that can be used instead of thermostats.

Aura Sensor

We recognise that our customers may not want thermostats in every room. Instead, Aura sensors can be installed. With no thermostats in each room the programming for the heating system is done from the ControlPad.

The sensor is very discreet and can be sited anywhere in the room provided it is not in direct sunlight or near a heat source and, of course, it isn’t covered.

Ì Discreet sensor Ì No thermostat needed Ì All settings changed at the ControlPad

The Aura wiring centre allows all the control wiring to be brought together in one place. LEDs show the status of the underfloor heating zones as well as any additional equipment installed such as the ventilation or hot water system.

Ì Simple, easy-to-follow wiring Ì LED indicators for all connected zones

and systems Ì Robust connectors

Aura Wiring Centre

The Aura TM1 thermostat is discreet and stylish with all the functionality needed from a modern thermostat. Programming is simple. There are four on/off periods simply input the time and temperature for each of these periods. Alternatively, the thermostat can be switched into non-programmable mode for simple temperature adjustment only.

Ì Simple-to-use features Ì Programmable or non-programmable Ì Stylish and unobtrusive design

Aura Thermostat

59

Page 62: Timoleon Specifiers Guide

Reduce energy consumption and improve the air quality with whole house ventilation.

Whole house ventilation provides a controlled way of introducing fresh air into the building removing the need for trickle vents above windows or opening windows at night. The system also extracts the damp stale air from kitchens and bathrooms.

This outgoing air is warm and this energy in a normal mechanical ventilation system would be lost outside. The Heat Recovery Unit has an integrated heat exchanger that transfers the energy from the outgoing air to the cold incoming air thereby minimising the heat loss due to the mechanical ventilation.

60

Page 63: Timoleon Specifiers Guide

Ventilation &

Heat R

ecovery

A Mechanical Ventilation and Heat Recovery (MVHR) system extracts the stale humid air from bathrooms and kitchens in the same way as conventional mechanical ventilation but instead of dumping the warm air outside the air is moved through internal ducting to a central Heat Recovery Unit (HRU) located in the loft or in a cupboard.

The HRU passes the outgoing air through the heat exchanger whilst simultaneously drawing fresh air from outside in the opposite direction. This process recovers up to 90% of the heat that would otherwise be lost whilst supplying fresh air in a controlled way throughout the building.

By extracting the damp air from bathrooms and kitchens condensation problems are reduced as well as mould growth and the build-up of pollutants. In addition the living environment is improved as windows do not need to be left open reducing noise, pollution and security issues.

What is MVHR and how does it work?

The heat recovery unit transfers the energy from the outgoing warm stale air into the incoming cold fresh air.

The heat recovery unit supplies fresh air through ducting into living rooms and bedrooms through valves in the ceiling or wall.

Outside air is drawn into the house through a roof cowl or air brick.

Air is extracted to the outside though a roof cowl or air brick.

2. Transfer through HRU

3. Supply to bedrooms & living areas

1. Outside fresh air

5. Extracted air

Stale humid air is extracted by the heat recovery unit from bathrooms and kitchens through valves in the ceiling or wall.

4. Extraction from bathroomsand kitchens

61

Page 64: Timoleon Specifiers Guide

Create the perfect environment by removing stale air and replacing it with fresh outside air.

Ì Moisture that causes mould growth is removed. Mould growth and other pollutants lead to a poor indoor air quality.

Ì Less condensation on windows Ì Provides better indoor climate Ì A controlled supply of fresh filtered air Ì Windows do not need to be left open

eliminating noise, pollution and security issues

Ì Eliminates noise from extract fans located within bathrooms

Ì Low maintenance Ì Less dust

Introducing fresh air into a house and extracting the stale air is essential to maintain comfort levels, to alleviate the potential build-up of contaminants and to reduce humidity in bathrooms and kitchens. Part F of the building regulations makes it mandatory for new homes to be properly ventilated. Mechanical extracts are usually installed to remove stale and humid air from bathrooms and kitchens. However the energy present in the warm air is lost when extracted outside, the heating system is then needed to reheat the incoming air.

The transfer of energy from the outgoing stale humid air to the incoming fresh air reduces the need for the heating system to re-heat the air. This saves energy and reduces the running costs of the heating system.

Key benefits of MVHR Systems Heat from ventilation loss is the single biggest component of energy loss in a modern building especially in Passivhaus design. This is because, no matter how air tight the building is, fresh air is always required and this needs to be heated. This supply of fresh air is conventionally provided by extracting stale air using mechanical ventilation from bathrooms and kitchens with fresh air coming from window vents in other rooms. The heat loss from mechanical ventilation can be significantly reduced by using MVHR to control and recover the energy that would otherwise be lost.

Our ventilation systems use the latest semi-rigid duct technology removing the need for many of the fittings required in a rigid duct system. As this is smaller and more flexible it is an easier and faster installation that suits both new-build and refurbishment.

By having less fittings and easy push fit joints air leakage is reduced and the single duct run to each room results in significantly less cross talk noise.

Installation is up to 50% faster than conventional rigid duct systems especially in suspended floors.

Semi-Rigid Duct

Ì Uses ‘lip type’ Thermo Plastic Elastomer (TPE) seals

Ì Securing clips grip into outer corrugations to keep joints locked together

Ì No need for silencers Ì Straightforward airflow balancing as

changes to one air valve will have less effect on the flow of air through the other outlets

Ì Less fittings required Ì More flexible, semi-rigid duct

makes it easier to go around obstacles, change direction and fit through joists

Ì Cutting and joining is quick and easy

Ì Flexibility means less accuracy required in measuring

No leaks

No cross talk between rooms

Simple & quick install

Easy to cut & join

62

Page 65: Timoleon Specifiers Guide

Ventilation &

Heat R

ecovery

Mechanical Ventilation and Heat Recovery (MVHR) systems consist of a central Heat Recovery Unit (HRU) located in the loft or in a cupboard with connected duct running to all the rooms in a house.

The HRU has two fans, one to extract the damp, warm air from bathrooms and kitchens and one to bring in fresh filtered air from outside. The HRU passes the outgoing air through the heat exchanger whilst simultaneously drawing fresh air from outside in the opposite direction. The two air streams are isolated from each other as they pass through the heat exchanger with the warm stale air transferring energy to the cooler incoming fresh air which is then supplied to bedrooms and living areas.

The MVHR System & the HRU

Dimensions HxWxD (mm)

HRX HRX-2

Weight (kg)

Max extract volume (l/s)

Max pressure (Pa)

Max sound (dB(A) @ 3m)

Thermally efficient EPP casing

Remote wiring centre

SAP appendix Q listed

SAP data (SFP (W/ls¯¹) / efficiency)

Kitchen + 1 wet room

11.5

72

550

35

755x564x290 600x935x530

20.0

133

450

35

Kitchen+ 7 wet rooms

Options/extras available:

Summer bypass option

Frost protection option

Bespoke condensate kit

Warranty (extended available)

0.58/88%

1.24/84% 0.77/91%

0.53/95%

2 years 2 years

SAP is the Government Standard Assessment Procedure for the energy rating of dwellings.

SAP Appendix Q enables performance of new technologies including MVHR to be used in SAP calculations. Our MVHR appliances easily satisfy the requirements of SAP Appendix Q. To achieve the highest Code for Sustainable Homes level, a SAP heat loss parameter (HLP) of 0.8W/m2K is required. This will not be achievable without MVHR.

Our integrated systems help our customers to achieve higher levels of the Code for Sustainable Homes and the best possible SAP ratings.

Appendix Q & MVHR

Ì Exceeds Parts F & L of the 2010 Building Regulations

Ì SAP appendix Q listed Ì Compact and lightweight Ì Wiring centre is mounted remotely

removing the possibility of moisture damaging the electrics.

Ì Design allows for left or right installation

Ì Summer bypass that efficiently channels air around the heat exchanger

A 15% reduction for intermittent heating at the peak load can be made when using an MVHR system. This is because the MVHR system will be recycling heat energy, preheating the fresh air that is supplied into the building reducing the peak load for a cold start.

MVHR and Micro-generation (MCS) calculations

63

Page 66: Timoleon Specifiers Guide

This is used for passing ductwork through a roof.

The manifold is used as a distribution system receiving air through 150mm duct from the Heat Recovery unit and distributing the air into each room using several smaller 75mm semi-rigid ducts. With inherent insulation and sound attenuation properties, this also helps prevent condensation and limit the escape of heat and noise, reducing the requirement for duct silencers.

Supplied in neatly coiled 50m lengths it is easy to handle, store and transport. Its smooth inner lining and strengthened corrugated outer layer are made from Low Density Polyethylene (LDPE) which makes it flexible in its application but hard wearing on site. It can be easily manipulated to changes in direction reducing the need for connectors and T-pieces and saving time on installation, however where sharper bends are required, there is a 90° bend and straight connector available.

The manifold connector provides an air tight seal for the 75mm semi-rigid duct as it is connected to the manifold. This reduces the need for traditional sealing methods such as mastic. Overall this improves the system performance by reducing air leakage.

This duct to room outlet adaptor moves the air from the ø75mm duct through 90° to a standard air valve connector. This reduces air speed on room entry, eliminating draughts and noise.

The ø150mm duct runs from the Heat Recovery unit to the manifold. Its insulating properties prevent condensation and limit the escape of heat and noise, reducing the requirement for silencers.

Used as a terminal fitting at an external wall.

The Heat Recovery Unit uses fans to extract air from inside the building and also introduce filtered air from outside. The two air flows pass through a high efficiency heat exchanger. Each Heat Recovery Unit has a summer bypass fitted.

1. Roof Cowl

5. Manifold

8. Ø 75mm Semi-Rigid Ducting

6. Manifold Connector

7. Outlet Plenum & Valve

2. Ø 150mm Ducting

3. Double Airbrick & Adaptor

4. Heat Recovery Unit

Timóleon MVHR systems have boost and summer bypass control.

What do you need?

Does the system run all the time,all year round?

Yes, the system constantly runs moving air at a low volume in and out of the building. The system will only operate on “boost” when activated.

What is the running cost of an MVHR system?

The electricity consumed by the MVHR system is very low and this is easily offset by the heat energy saving. The running cost will vary but is in the region of 25p to 30p/day.

What will happen if there is no power?

If the MVHR system should not operate over several hours you will begin to notice the room becoming stuffier especially in bathrooms however there is no risk of suffocation.

Is it noisy?

In continuous mode the HRU is barely audible. In boost mode because of the extra volume extracted the noise is increased slightly to 35dB at 3m (a computer is typically 40dB).

Ventilation Systems FAQ

64

Page 67: Timoleon Specifiers Guide

Ventilation &

Heat R

ecovery

Outside air is drawn into the house through a roof cowl or air brick, as shown in the illustration (1 & 3). The heat recovery unit (4) then transfers the energy from the outgoing warm stale air into the incoming cold fresh air.

The air is then extracted to the outside, again though a roof cowl or air brick. Meanwhile, the heat recovery unit supplies fresh air through ducting (8) into living rooms and bedrooms through a valve in the ceiling (7).

Finally, stale humid air is extracted by the heat recovery unit from bathrooms and kitchens through a valve in the ceiling.

Timóleon also supplies rectangular or round rigid duct where appropriate including acoustic silencers, insulated duct and fire brakes.

OU

TLET P

LEN

UM

& VA

LVE

Ø 75M

M S

EM

I-RIG

ID D

UC

TING

HE

AT RE

CO

VE

RY

UN

IT

MA

NIFO

LD C

ON

NE

CTO

R

DO

UB

LE A

IRB

RIC

K &

AD

AP

TOR

RO

OF C

OW

L

MA

NIFO

LD

The MVHR System

1

2

3

4

5

6

7

8

65

Page 68: Timoleon Specifiers Guide

60 years ago, the concept of circulating high temperature water from a boiler through radiators fitted in each room was still new. Since then, it has become the standard way of heating most buildings in the UK. The consequence is that more than 99% of the buildings in the UK are now dependent for their heating on a central boiler which uses a fossil-fuel.

Yet we all know that these fuels are becoming increasingly more expensive. Government figures record that 4 million UK households were already in “fuel poverty” in 2009.

Despite this, we continue to fit new buildings with heating systems that are dependent on high temperature fossil-fuel boilers.

What is the alternative?

The recent big change has been the development of a new generation of high-performance underfloor heating products, for both retrofit and new build, which are able to provide very comfortable and effective heating while using water which is only 35-45˚C. Along with this, a new generation of solar thermal technology has been developed that can more effectively store and use the energy collected from solar thermal even on a winter’s day.

These two developments - low temperature underfloor heating combined with a clever solar thermal storage and control system - mean that up to 40% of the building’s heat load can be satisfied by energy collected from the sun.

Lower bills, faster payback and less reliance on fossil fuels.

Timóleon underfloor heating systems are designed to use low water temperatures, low enough to use the heat collected by a solar thermal panel.

Timóleon SunCylinder. Using solar thermal energy for the heating system.

66

Page 69: Timoleon Specifiers Guide

So

lar Heating

Simply, solar thermal panels during the winter have far less incident solar energy than in the summer. In these conditions the solar panel can still collect a reasonable amount of energy but at a low water temperature which isn’t useable by most heating systems such as radiators.

Solar thermal can be used to contribute to the heating system. There are four dimensions that are crucial to making this work:

1. Heat emitters designed to work at low water temperatures.

2. A control system that recognises when the stored low temperature water can be used for the heating system.

3. A way of storing the water to make best use of it for both the heating and hot water.

4. An efficient and correctly sized solar array.

Timóleon underfloor heating systems are designed to be effective when using low water temperatures. This means that the energy collected and stored by the solar thermal panels during the winter, autumn and spring can be used without the need to automatically run the boiler or heat pump. The SunCylinder system provides the necessary storage and control to make this work.

Why don’t we normally use heat collected from Solar Thermal in our heating systems?

How do we use solar energy in our heating systems?

67

Page 70: Timoleon Specifiers Guide

The SunCylinder system works by making full use of energy collected by the solar thermal panels even when this is stored at relatively low water temperatures.

The SunCylinder system has a unique control that calculates the required heating system water temperature, if this required temperature is lower than the water in the cylinder then it will use this stored energy before firing the boiler.

For example when the weather is very cold, say -3˚C, then the underfloor heating system may need water at 45˚C but when the outside temperature is higher, around 8˚C, the required water temperature will be lower, say 35˚C. If the water in the cylinder is above 35˚C the control system uses the heat stored in the cylinder rather than activate the boiler or heat pump. As soon as the water temperature in the cylinder drops to an unusable level then the boiler or heat pump is used. This method of control makes better use of the solar thermal energy.

A conventional heating system will fire a boiler when there is demand, heating up the thermal store to 60˚C or 70˚C regardless of what temperature is needed by the heating system. When water is stored at this high temperature it is impossible for the solar thermal to be able to store any further energy collected from the panels.

1. Solar Thermal sized for SunCylinder

5. Timóleon low temperature underfloor heating and Aura control system

2. SunCylinder system

How does it work?

3. Control box

4. Pre-assembled jig

1 2

3

4

5

SunCylinder halves the payback time on solar compared to using a thermal store.*

*This is dependent on the type of fuel used, the solar thermal input, the heating system design and how the heating system is used.

68

Page 71: Timoleon Specifiers Guide

So

lar Heating

Of the home energy load from Solar Thermal using conventional technology.

Heating & Hot water using SunCylinder

Hot water from solarTotal House Load

Solar Thermal for DHW The Competition

Using SunCylinderSolar Thermal Using SunCylinder

Total House Load Hot water and heating from Solar

A standard twin coil solar cylinder is expected to provide 60% of the hot water load throughout the year. The hot water load is 25% of the home’s energy load therefore a twin coil cylinder provides 15% of the home’s energy use.

Alternatively, some systems use a three coil thermal store for heating and hot water. However, on demand, the thermal store will have to heat the stored water to a fixed temperature, usually 65˚C or 70˚C. The use of the solar thermal during the spring, autumn and winter becomes limited as storing water at high temperature makes it impossible for the solar thermal to contribute energy collected at low temperature.

What makes our system different?

Compare this to SunCylinder. SunCylinder is primarily designed to be used for heating rather than hot water. The SunCylinder system is designed to contribute up to 40% of the heating load for the year. As the home’s heating load is 75% of the total load then the SunCylinder system can contribute 30% of the home energy PLUS some of the domestic hot water demand especially through the summer months. SunCylinder has a much faster payback as a result, between 6 and 15 years depending on the type of fuel, the solar thermal input and how the heating system is used.

Of the home energy load from SunCylinder technology.

15% Up to

Up to40%

69

Page 72: Timoleon Specifiers Guide

What is the SunCylinder system?

A unique patented cylinder design is used in conjunction with a control system.

The cylinder has two input coils, one coil for solar thermal and a second coil for the auxiliary heat source, this coil is sized so either a boiler or heat pump can be used.

The third output coil supplies the Timóleon underfloor heating system. The cylinder has the same footprint as a conventional cylinder with all the coil and sensor connections located conveniently on one side.

The control system uses a pre-assembled “jig” for simple onsite installation, this includes the necessary valves and circulator. The electronics are contained within the control box and provides an easy way to set up and commission the system as well as providing connection for the sensors and valves.

Patented 3-coil cylinder

Control box

Pre-assembled jig

T&P Valve

Delta “T” Sensor

PRV

Cylinder Sensor

Sensor Pockets

DHW Temperature Sensor

Portable Water Expansion Vessel

Mixed Water Temperature Sensor

2no. Immersion Heaters

External Air Temperature Sensor

Ì Either 382 or 510 litre cylinder Ì Full Unvented Kit for the cylinder including all the below

Ì Weather Compensator & DHW Programmer

Ì Blending Valve Ì Electric head Ì Standard 15/50 pump Ì 22mm Zone Valves

Description

Storage Capacity

Overall Diameter

Overall Diameter incl.

Immersion heaters

Overal height with

expansion vessel on

cold feed supply

Weight when full

Primary flow/

retrun connections

Primary flow/

return connections

Solar coil area

UFH output coil area

Auxillary

heating coil area

Expansion Vessel Size

382 litre with boiler coil

382 litres

580mm

642mm

2100mm

440kg

22mm

28mm

2.0m2

2.0m2

1.2m2

Boiler coil

35 litre

510 litre with boiler coil

510 litres

663mm

725mm

2057mm

570kg

22mm

28mm

2.0m2

2.0m2

1.2m2

Boiler coil

80 litre

382 litre with heat pump coil

382 litres

580mm

642mm

2100mm

440kg

22mm

28mm

2.0m2

2.0m2

3.0m2

Heat Pump coil

35 litre

510 litre with heat pump coil

510 litres

663mm

725mm

2057mm

570kg

22mm

28mm

2.0m2

2.0m2

3.0m2

Heat Pump coil

80 litre

The SunCylinder system and what'sincluded.

70

Page 73: Timoleon Specifiers Guide

So

lar Heating

UNDERFLOOR HEATING OUTPUT COIL

BOILER OR HEAT PUMP INPUT COIL

SOLAR THERMAL INPUT COIL

71

Page 74: Timoleon Specifiers Guide

Information on a range of services we can offer from energy consultancy to training. This section also contains information on a few of our most common technical questions.

We have an extensive technical team that will provide a dedicated Project Manager to work with you through the whole project from the quote to commissioning.

Help & Advice. Designed to help our customers and partners get what they need.

72

Page 75: Timoleon Specifiers Guide

Here to

help

73

Page 76: Timoleon Specifiers Guide

The training addresses the total amount of energy used by UK buildings and how this must reduce. It introduces the European Energy Performance of Buildings Directive, EEPBD, which drives Building Regulations Part L. The training explains the science behind how UFH and radiators work, and how this relates to the new design principles. It describes the constituent elements of any UFH system, how these inter-relate and how these elements differ from the elements of a radiator system. The training goes into some detail, showing how UFH can be incorporated into any form of floor construction, including acoustic floors. Finally, the training considers how UFH works in conjunction with the whole range of different floor finishes, and concludes with its relevance to Renewable Energy.

Our tailored courses are designed so users get the best out of our unique products.

RIBA CPD

Heating Buildings with Renewable Energy

Introduction to Underfloor Heating

Timóleon provides two RIBA approved CPD courses. Learn about underfloor heating, its background and key features, or understand more about heating buildings with renewable energy.

Where we are currently in the UK with regard to Renewable Energy, what are the pressures and consequences of the Government’s national CO2 target and what we have recently learned about how to reduce a building’s CO2 level. The training proposes steps we have to take in order to reduce the amount of energy a building uses in the future, and it’s CO2. The training considers Renewable Energy technologies collectively and then discusses them individually, explaining how they inter-relate. Finally, the training explains which key steps need to be taken first in order that other phases of RE can be more easily added to a building later in its life.

Book your RIBA CPD training today by emailing [email protected].

If you would like to book an installer course, or find out more, call us on 01392 36 36 05.

Booking courses

74

Page 77: Timoleon Specifiers Guide

Here to

help

We provide in-house tuition for underfloor heating and ventilation systems at our training centre in Exeter. We have working systems that give an installer hands on tuition as well as providing the theoretical background. Also, for anyone not familiar with our products we will provide on-site training and support.

Training for installers

Timóleon provides an independent specialist service that commissions, services and troubleshoots any type or make of underfloor heating system.

A properly commissioned and maintained system will reduce energy bills, maximise the life of its components and reduce the property’s carbon footprint.

Our experienced field personnel, together with our technical team can troubleshoot and fix problems where they occur. They can also carry out regular servicing and offer advice on the most effective way to control a system so that it continues to give the very best energy performance.

Servicing & Commissioning

Timóleon trained assessors work closely with architects, specifiers, developers and installers.

75

Page 78: Timoleon Specifiers Guide

Code for Sustainable Homes

The Code for Sustainable Homes is an environmental assessment applicable to new build residential developments. We will allocate an assessor as your single point of contact for all technical matters throughout the code process.

SAP (Standard Assessment Procedure) and SBEM (Simplified Building Energy Model)

We have accredited Domestic Energy and SBEM Assessors who can work closely with developers, architects, specifiers, contractors and end users to provide SAP and SBEM assessments for:

Ì New Build at both the design stage and ‘As Built’ Ì For change of use, extensions, renovations and refurbishments

We can work from a supplied specification whilst also looking at site specific alternatives that could be incorporated to improve the overall efficiency and rating of the building. We can also look at finished projects that have failed at the ‘As built’ stage and work with clients to find the most cost effective solutions for achieving a pass.

Reducing energy consumption is vital. With Tonos, we can help you do it.

Tonos focuses on a whole house approach working closely with clients to provide a strategy to meet their design requirements, from bespoke buildings through to large developments.

We provide a number of energy consultancy services to help you specify the right system for your project.

[email protected]

MCS (Microgeneration Certification Scheme) Heatlosses

We provide heatlosses for all project types and technologies, including biomass, gas and all types of heat pumps. It is now a requirement for heatpump technologies to provide compliant heatloss calculations in accordance with MIS3005. This standard requires that specific criteria for the heat loss calculations are met and assesses whether the heat pump and heating emitters (UFH and radiators) meet the room by room calculations. As part of the Renewable Heat incentive (RHI) it will be necessary to confirm that the heat pump and emitters meet 100% of the heating load.

As part of our report we will provide information on the energy consumption and potential running costs. Tonos also provides comparative running costs set against other renewable technologies and fuel types. We can also provide;

Ì U value calculations Ì Site surveys/ thermal imaging Ì Recommendations/ advisory notes for improvements to the building

Renewable Feasibility and strategy

Tonos will assess the project, site and surrounding area to provide a balanced report that details all the renewable energy options that are practical and financially viable. We will provide bespoke and impartial information which will guide your decision making, providing detail on recommended technologies with informed considerations for installation. Our reports also provide information on potential payments through the Renewable Heat Incentive (RHI), Feed in Tariffs (FITS) and payback periods for your investment. Tonos understand concepts for low carbon developments, promoting low embodied energy materials and sustainable design concepts.

We are Tonos

76

Page 79: Timoleon Specifiers Guide

Here to

help

77

Page 80: Timoleon Specifiers Guide

Placing an order

Getting a quote and specification

Orders can be placed through your local merchant. They will need to know when the goods are required and the site address (unless it is being delivered to the branch) and a copy of your quote. The merchant will then call the Project Manager to organise delivery.

From order we will provide a comprehensive underfloor heating design for your approval. Once agreed the materials will be dispatched and sent to site or the branch as required. Depending on design approval the process will take up to 10 working days.

To get a quote simply email your plans to [email protected] or use the online facility at timoleon.co.uk. We have provided a quote request form at the back of this brochure should you wish to fax or post your plans.

When sending in your plans please provide details of the floor construction, the floor finishes and the type of heat source. We would also like to know the insulation levels and glazing type. If it is a new build then simply state “built to current regs”.

There are product specifications on all of our published datasheets. However, if you would like to discuss your project with us then please call the project team.

At Timóleon, we are committed to providing the highest quality service, with dedicated project managers assigned to your project from quote to install.

Timóleon provides a comprehensive quoting and specification service. However, we appreciate that sometimes a quick price is needed without the specification and detail.

Simply send your plans to us with details of the floor construction and we will get a price back to you within 24 hours. If you need a more thorough room-by-room quotation and specification then please allow a bit longer.

When we receive an order our standard procedure is to produce a detailed design and issue for approval before we then dispatch the materials. However if materials are needed in a hurry then Express Delivery offers a quick but simple way of getting standard products to site with a design for projects under a 100m2.

Once we have received the order from the merchant we will aim to have the materials on site within 48 hours. We will produce the underfloor heating design as normal but rather than issue for approval we will dispatch the plans with the materials. As there is no time for design approval any on-site changes have to be met by the materials sent.

Quick Quote

Express Delivery

78

Page 81: Timoleon Specifiers Guide

Here to

help

79

Page 82: Timoleon Specifiers Guide

System

Schem

atic

1

2

12

3

4

5

6

7

811

9

10

1314

1. Boiler

2. Hot w

ater switch

3. Hot w

ater cylinder and

thermostat

4. Hot w

ater valve5. R

adiator sw

itch6. R

adiator

7. Rad

iator valve8. A

ura thermostats and

sensors9. W

iring centre10. U

nderfloor heating m

anifold11. A

ura touch screen central control12. H

eat Recovery U

nit13. B

oost switch

14. Sum

mer b

ypass sw

itch

80

Page 83: Timoleon Specifiers Guide

Here to

help

General Information

TN 03 Introducing StreamlineTN 04 Introducing TonosTN 06 Guarantees & Warranty Information

TECHNICAL INDEXES Overview of Constructions, Systems & Processes

TX 100 Acoustic ConstructionsTX 101 Domestic Ceiling ConstructionsTX 102 Commercial Ceiling ConstructionsTX 103 Ceiling Cooling SystemsTX 104 Floor CoveringsTX 105 Battened FloorsTX 106 Screeded FloorsTX 107 Floating FloorsTX 108 Suspended FloorsTX 109 Energy SourcesTX 110 Thermostats & ControlsTX 111 Underfloor heating & surface coolingTX 112 Heat Recovery & Ventilation systems

To access documents in our technical index, simply type in 'www.timoleon.co.uk' into your browser followed by the name of the document you wish to view. For example, 'www.timoleon.co.uk/tx100.pdf'

Alternatively, call the project team on 01392 36 36 05 to request printed copies of all the documents mentioned here.

Index of our publications

TECHNICAL INFORMATIONDetailed Technical Specification & Supplied Data

TI 1001 StaplesTI 1003 ClipPlateTI 1004 FoilBoard BattenTI 1005 FoilBoard FloatingTI 1007 FoilBoard SuspendedTI 1008 FoilBoard for Domestic CeilingsTI 1009 FoilBoard Modular GridTI 1010 ToronFloor BattenTI 1011 ToronFloor SuspendedTI 1012 AB PlateTI 1013 FoilBoard SRBTI 1014 FoilBoard Modular SuspendedTI 1015 LowBoardTI 1016 OgeeBoard InsulationTI 1017 InterDeckTI 1018 RAF Plate

TI 5001 Staple installation guideTI 5002 ClipPlate installation guideTI 5003 FoilBoard Batten installation guideTI 5004 FoilBoard Floating installation guideTI 5005 FoilBoard ECO Suspended installation guideTI 5006 AB Plate installation guideTI 5007 FoilBoard Timber Suspended ceiling installation guideTI 5008 FoilBoard Modular Grid ceiling installation guideTI 5009 ToronFloor Suspended installation guideTI 5010 ToronFloor Batten installation guideTI 5013 FoilBoard Modular Suspended installation guideTI 5014 LowBoard installation guideTI 5015 OgeeBoard Insulation installation guideTI 5016 InterDeck installation guideTI 5018 RAF Plate installation guide

TI 6001 Underfloor Heating Manifold installation guideTI 6003 Underfloor heating commissioning and servicing

TI 7001 Wiring diagrams

TI 8001 MVHR Maintenance and Servicing

TI 9003 Underfloor heating and Part LTI 9004 Underfloor heating and BS1264TI 9005 Energy Performance of Buidlings DirectiveTI 9006 Underfloor heating and Warm-up timesTI 9007 Underfloor heating outputs and flow ratesTI 9008 Underfloor heating and Heat LossTI 9009 Weather Compensation and Optimisation

Useful tip

81

Page 84: Timoleon Specifiers Guide

Name

Company

Address

Post Code

Telephone

Mobile

Email

Project Name

Site Address& Postcode

Overview of Requirements

What is your role in the project?

Architect/Specifier

Underfloor Heating Solar Heating

Developer

Contractor

Plumber/Installer

Ventilation & Heat Recovery

Self-Builder

Other

Please estimate the delivery date required for the systems:

D D M M Y Y

What is the type of project?

New build Refurbishment

Other

Extension

Commercial Conversion

What are the floor constructions (if you know them)?

Screeded Floor

Floating Floor

Floating Floor (Acoustic)

Battened Floor

Battened Floor (Acoustic)

Joisted Floor

Joisted Floor (I-Beam/Pozi)

B G 1 2 3 5

What are the intended heat sources:

Condensing Boiler Biomass

Ground Source Heat Pump

Solar

Air to Water Heat Pump Other (Please specify)

4 6 7

D D M M Y YDate

Building Fabric Properties - Presumed air changes and room temperatures based on building regulations.

Single Glazing

Exisiting Double Glazing

New Double Glazing

Triple Glazing

Or state U-Value W/m2k

Soild (uninsulated)

Solid (dry lined)

Cavity (unfilled)

Cavity (filled)

Or state U-Value W/m2k

Pitched (uninsulated)

Pitched (insulated)

Flat

Or state U-Value W/m2k

To current regulations

Glazing: Walls: Roof Construction:

To current regulations

To current regulations

Specification Form // Please choose:

For a quick quotation, you can fax this document along with floor plans to us on 01392 364871 or scan and email to [email protected]. Alternatively, send by post to: Timóleon, Unit 18 Apple Lane, Sidmouth Road, Exeter, Devon, EX2 5GL

Area (m2)

Page 85: Timoleon Specifiers Guide

Here to

help

Notes

Quick guide to Floor Surface Temperatures

Room Temperature (˚C)

Heat Output (W/m²)

Floor Surface Temperature (˚C)

40 W/m² 60 W/m²50 W/m² 70 W/m² 80 W/m²

18˚C 18˚C18˚C 18˚C 18˚C20˚C 20˚C20˚C 20˚C 20˚C22˚C 22˚C22˚C 22˚C 22˚C

23.5˚C 26.2˚C24.8˚C 27.6˚C 28.9°C25.5˚C 28.2˚C26.8˚C 29.6˚C 30.9°C27.5˚C 30.2˚C28.8˚C 31.6˚C 32.9°C

83

Page 86: Timoleon Specifiers Guide

Underfloor heating systems are often considered the most comfortable way of heating a building. However, the performance of an underfloor heating system is often unknown as there are several factors that influence the heat output i.e. the construction, the method of transferring heat from the pipe into the floor, the floor finish and the water temperature.

Timóleon has developed this application to enable specifiers and installers to understand how well systems work with certain floor finishes and water temperatures. This can then be used to compare with the building heat losses.

It is important to know that using a different floor finish won’t make the underfloor heating system ineffective. Equally, will the heat output from the underfloor heating be enough if a heat pump is installed working at low water temperatures?

With the Timóleon app you will be able to tell what the floor surface temperature will be at certain heat outputs, making it a vital tool for specifiers and installers alike.

The free Timóleon application is simple to use and produces accurate algorithms for your underfloor heating project.

The data provided by this app is indicative and applies only to Timóleon systems and products. Please contact Timóleon for project specific data.

Timóleon's pioneering free underfloor heating app updated with our latest range of underfloor heating products for all types of floor constructions.

Search the App Store for 'Timóleon' or visit timoleon.co.uk/iphone-application.html

Download

84

Page 87: Timoleon Specifiers Guide

Here to

help

Here to help with product maintenance, project management or general queries.

Call us on 01392 363605, email us at [email protected] or visit usonline at www.timoleon.co.uk

Alternatively, why not visit us in Exeter? Our premises have a surface heating and cooling system installed in the offices and an underfloor heating system in the structural floor of our warehouse. The building consumes 75% less energy than a building of its size using normal heating methods.

TimóleonUnit 18 Apple LaneTrade CityExeterDevonEX2 5GL

T 01392 363605F 01392 364871E [email protected] www.timoleon.co.uk

Send us your project drawings today & get a specification & quote.

Call for a quick quote and we'll get a price back same day, guaranteed.

If you need materials to site quickly, we'll get them delivered in 48 hours with design plans.

See page 78 for details.

General queries

If you require a RIBA CPD Presentation please call us on 01392 36 36 05 or email us at [email protected]

RIBA CPD

85

Page 88: Timoleon Specifiers Guide

Ì All products and materials sourced from reputable companies who adhere to ISO14001 standards where possible.

Ì All wood products are sourced from FSC or PEFC compliant chain of custody for sustainability.

Ì All insulation products have a low GWP (below 5) and meet the criteria set out for Code compliant insulation in the Pollution and Material sections.

Ì We try to minimise transportation of materials for collection and delivery and where possible source from local suppliers.

Ì Timóleon encourage car share, and provide safe bicycle storage to encourage cycling to work.

Ì We promote renewable technology and energy conservation as one of the primary objectives for the company.

Ì We have a strict in-house recycling policy for all materials used within the building.

Ì All paper used for documentation is made from recycled paper where possible.

Environmental Policy

86

Page 89: Timoleon Specifiers Guide

Here to

helpTN 13 © Timóleon Limited 2013. Information correct at time of going to press.Timóleon, the Timóleon logo and the Timóleon Laurel device are trademarks of Timóleon Limited. All rights reserved.

87

Page 90: Timoleon Specifiers Guide
Page 91: Timoleon Specifiers Guide
Page 92: Timoleon Specifiers Guide

TimóleonUnit 18 Apple LaneTrade CityExeterDevonEX2 5GL

T 01392 363605F 01392 364871E [email protected] www.timoleon.co.uk