solving challenging hvac/r problems is …icpindexing.toddsit.com/userfiles//fast motors...

48
AFTERMARKET MOTOR & ACCESSORIES GUIDE Your FAST ® Parts distributor has a full line of reliable replacement aftermarket motors & accessories at affordable prices. FAST ® Parts – International Comfort Products

Upload: others

Post on 06-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

AFTERMARKET MOTOR & ACCESSORIES GUIDE

SOLVING CHALLENGING HVAC/R PROBLEMS IS YOUR JOB.

HELPING YOU GET THE PARTS, SUPPLIES AND EQUIPMENT YOU NEED IS OURS.

Your FAST® Parts distributor has a full line of reliable replacement

aftermarket motors & accessories at

affordable prices.

FAST® Parts – International Comfort Products

Page 2: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

READY FOR ANYTHING

FAST Parts | International Comfort Products | www.fasthvacrparts.com

WITH OUR UNIVERSAL AFTERMARKET MOTORS & ACCESSORIES YOU’LL BE PREPARED FOR ANY REPLACEMENT JOB

EXTENDED WIRES

Gives contractors flexibility on the

installation

EXTENDED BOLTS

Easy one person installation, more flexibility

to fit most brands

NEW HI TEMP MODELS

Full line-up of 70°C motors, Ideal for high ambient temperatures

BALL BEARINGS

Standard on condenser fans for performance and

longer motor life

OUR FIVE-POINT CERTIFICATION

UNIVERSAL SHELL MOUNTING HOLES

Allows for universal, easy mounting in other brands

Ensures every motor meets uncompromising quality standards. So you can be confident you’re choosing the right motor for any replacement job.

DESIGN LIFEManufactured to precise specs for lifespan of 10+ years with proper installation.

SHIPPING & PACKAGING Tested to ensure minimal vibration and maximum impact resistance during transit.

PERFORMANCE VERIFICATIONRPMs, amps, rotation, temperature rise & capacitor voltage validated.

LOAD RATINGThoroughly tested to ensure reliability under maximum load conditions.

SAFETYUL & CSA certified, all code requirements met.

MOTOR FEATURES

Page 3: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

TABLE OF CONTENTSMOTOR INFORMATION

General Information

Definitions .............................................................................. Page 2

Selection ................................................................................. Page 3

Tips to Identify a Motor

without a Nameplate ................................................. Pages 3-4

FAST® MOTORS

FAST Direct Drive Blower Motors ...................................Pages 5

FAST Condensor Fan Motors ............................................Pages 6

FAST High Temp Condensor Fan Motors ...................Pages 7

DIRECT DRIVE BLOWER MOTORS

Nidec Permanent Split Capacitor Frame 48 ...............Page 8

Nidec Shaded Pole Flex Mount .........................................Page 9

CONDENSER FAN MOTORS

Nidec Permanent Split Capacitor ...................................Page 10

PSC Condensor Fan High

Temp Nidec Mojave Series ...................................................Page 11

Shaded Pole Unit Bearing ....................................................Page 11

Rescue® PSC Condenser Fan Motors .............................Page 12

GENERIC REPLACEMENT MOTORS

Evergreen® Aftermarket EM X13 Replacement .........Page 13

Evergreen® Aftermarket IM PSC Replacement ....... Page 14

Evergreen® Mounting Kits .................................................. Page 14

GENERAL PURPOSE MOTORS

Nidec Double Shaft Fan Motors .......................................Page 15

Nidec General Purpose Single Phase .............................Page 16

Nidec General Purpose Three Phase ..............................Page 16

BELTED BLOWER MOTORS

Nidec Split Phase Belted Fan and Blower ...................Page 17

Nidec Capacitor Start Belted Blower .............................Page 17

OIL BURNER MOTORS

Nidec Oil Burner Motors ......................................................Page 18

COMMERCIAL MOTORS

Nidec Commercial Three-Phase

Condenser Fan Motors ........................................................ Page 19

Baldor® HVAC Integral Motors

General Purpose ODP .........................................................Page 20

Baldor® HVAC Integral Motors

General Purpose TEFC ..........................................................Page 21

Baldor® HVAC Integral Motors

Variable Torque ODP ............................................................Page 22

FAST® FAN BELTS

Fractional HP V-Belts ..................................................Pages 23-24

Multiple V-Belts ..............................................................Pages 25-26

Narrow V-Belts, Cogged .....................................................Page 27

BROWNING BELTS

FHP Belts ....................................................................................Page 28

Super Gripnotch® Belts .......................................................Page 28

Gripnotch® Belts .....................................................................Page 29

"358" Gripbelt® and Gripnotch® Belts ...........................Page30

BROWNING SHEAVES

Cast Iron Browning .......................................................Pages 31-32

FAST® CAPACITORS

Oval Motor Run Capacitors Dual - 370V .....................Page 33

Oval Motor Run Capacitors Dual - 440V ....................Page 33

Oval Motor Run Capacitors Single - 370V .................Page 34

Oval Motor Run Capacitors Single - 440V .................Page 34

Round Motor Run Capacitors Dual - 370V ................Page 35

Round Motor Run Capacitors Dual - 440V ................Page 35

Round Motor Run Capacitors Single - 370V .............Page 36

Round Motor Run Capacitors Single - 440V ............Page 36

PARTS & ACCESSORIES

Motor Diagnostics .........................................................Pages 37-38

Motor Mounting .............................................................Pages 37-38

Bearing Brackets............................................................Pages 38-39

Bearings ............................................................................ Pages 39-45

www.FASTHVACRparts.com | 1

Page 4: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

2 | Aftermarket Motor & Accessories Guide

MO

TO

R IN

FO

RM

AT

ION

MOTOR INFORMATION

SHADED POLE MOTORS Single Phase For use in light-duty appliances because of low efficiency, power factor and starting torque. These motors are only suitable for direct drive fan and blower applications.

PERMANENT-SPLIT CAPACITOR MOTORS Single Phase This type motor is similar to the shaded pole type but has higher efficiency and power factor. Starting torques are relatively low which limits application only for direct drive fan and blower applications.

SPLIT-PHASE MOTORS Single Phase Split-phase motors have moderate starting torque with low starting current. They are used where starting load is moderate and where there is frequent starting with rela-tively long running periods. Reversible.

CAPACITOR-START MOTORS Single Phase This type motor produces greater locked-rotor and ac-celerating torque per amp than the split phase type. With a higher starting torque than the split-phase type it can be used for driving compressors, pumps, air conditioning equipment and many other hard-to-start applications.

POLYPHASE-SQUIRREL CAGE INDUCTION MOTORS Three Phase Polyphase motors have a high starting torque combined with high efficiency and power factor which makes them suitable for use on larger compressors and commercial air conditioning units. Do not require capacitors or starting relays. Reversible.

DEFINITIONS FOR LISTING ON FOLLOWING MOTORS PAGESHP: Horsepower - Power rating of the motor

FLA: Full Load Amps - Amperage drawn by a motor when operating at rated load and voltage. NOTE: RCD may use several motor suppliers for

any given part number. Therefore FLA listed represents maximum rating that could be encountered under a given part number.

RPM: Synchronous speed or full load speed

HZ: Frequency or Hertz

V: Voltage AC

: Rotation Reversible

oC : Ambient Rating

CAP : Capacitor Rating (i.e. 5.0 μF / 370 volts)

A : Amp rating at Full Load (i.e. 1.8A)

DEFINITIONS

PSC : Permanent Split Capacitor motors single phase. This type of motor has high efficiency and power factor with starting torques relatively low, which limits the application only for direct drive fan and blower applications.

TE : Totally Enclosed Motor

OP: Open Enclosure

Speed: 1 : Single Speed Motor

Mounting : Base, Stud, Strap

ROT. : Rotation - Motors rotate in either a clockwise (CW) or counterclockwise (CCW) direction. Rotation listed is per NEMA, as viewed from the end of the motor opposite the shaft. In the case of double shaft motors, the rotation is viewed from the lead end of motor.

SF : Service Factor - A measure of the overload capacity designed into a motor. A 1.15 SF means the motor can deliver 15% more than a rated horsepower without injurious overheating. A 1.0 SF motor should not be overloaded beyond its rated horsepower.

BRGS : Bearings - SLV/BALL

FRAME : An (R), (S) or (T) may appear in this column adjacent to the NEMA frame designation and is defined as follows: (R) - Resilient mounting rings included (S) - Motor is mounted on rigid base (T) - Motor is equipped with extended thru-

bolts required for thru-bolt mounting

DIA : Diameter of motor in inches

SHAFT : Length/Diameter (i.e. 6.5” / 1/2”). First shaft length listed is at lead end of dual shaft motors. NOTE : RCD may use several motor suppliers

for any given part number. Therefore, shaft length(s) listed represent maximum length(s) available under a given part number.

PROTECTOR : Internal Thermally Protected

MOTOR DIMENSIONS:A. Overall length of motor including shaft(s)

B. Diameter of mounting bold circle on motors supplied with mounting ears

C. Shaft height - center of shaft to base on motors sup-plied with mounting base

D. Diameter of mounting hole on motors supplied with mounting lugs

Page 5: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 3

MO

TO

R IN

FO

RM

AT

ION

MOTOR INFORMATION

MOTOR SELECTION

When selecting either an indoor blower motor or outdoor condenser motor, always start with the following:

HP: Always try to use the same horsepower that was in the original equipment application, specifically within that frame size

RPMs: Selected should be in the 10% range

AMPS: Never exceed the full load amps by more than 10%

Voltage: Should always be the same as the equipment

Capacitor: May require a change to reflect the microfarads (μF) required by the motor (i.e. 5μF to 7.5μF)

INSTALLATION TIPS

Before installing motors always measure the approximate propeller fan, or blower wheel location to make sure your final installation ends up in the same area in condenser orifices or blower housings to maintain the same air flow.

Make sure the hubs of the old fans or blower wheels are not stripped and the set screws are tight to the flat of the shaft.

Outdoor propeller fan blades flex during operation. Make sure you have enough clearance so that the fan blades do not contact the mounting screws of the motors on the shaft end. (If necessary, cut the installation screws back to avoid a fan hit.)

Motor must be securely and adequately grounded by wiring per NEC and local codes.

TIPS TO IDENTIFY A MOTOR WITHOUT A NAMEPLATEMotor Diameter: Measure diameter to confirm NEMA (National Electrical Manufacturers Association) frame size. Frame size: 4.9”= 42, 5.6”= 48, 6.5”= 56

Motor Type: Shaded Pole (SP), Permanent Split Capacitor (PSC), Split Phase, Capacitor Start/Capacitor Run, Three Phase, and DC.

Number Of Speeds: • Number Speeds = number of power leads minus 1.

• For SP - Do not count the ground (green) lead.

• For PSC - Do not count the ground (green) lead or the capacitor (brown) lead.

Mechanical Features: • Mounting Definition - Base, Belly band, Lugs, Studs, Face

mount, etc.

• Enclosure - ODP (Open Drip Proof), TE (Totally Enclosed), etc.

• Shaft - Number, Length, Diameter, Flat-Keyway, etc.

• Unique Features - Leads, Conduit Box, Bearings, Brake, Rotation Arrow, Capacitor Cover, Slingers, etc.

Rotation: • Most standard motors (except Single Phase and Threaded

Shaft) are reversible from standstill by electrical reconnection.

• Three phase motors reversed by interchanging any two of the three power leads. Note: Rotation of an unknown motor is often found by

noting attached fan, blower or other device. Dirt accumulates on the side towards which the motor rotates.

Typical Color Schemes (Not a standard): • White - Common lead (115 volt)

• Yellow or Purple - Common lead (230 volt)

• Black - High

• Blue - Medium

• Red - Low

• Brown - Capacitor leads (1 or 2)(PSC Only)

• When replacing PSC a good practice is to replace the capacitor, too.

• Replace based on horsepower not AMP rating.

• Do not replace manual overload with automatic overload motor.

• Motors with similar stator dimensions will have output (other features being equal). i.e. It takes a similar amount of iron and copper (D2L) for torque.

Page 6: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

4 | Aftermarket Motor & Accessories Guide

MOTOR INFORMATION

MO

TO

R IN

FO

RM

AT

ION

TIPS TO IDENTIFY A MOTOR WITHOUT A NAMEPLATE cont.

SPEED: RPM = 120 X HZ / # POLES

@ 60HZ # POLES

FULL LOAD SPEED GENERAL PURPOSESYN SP PSC

2 3600 3000 - 3450

4 1800 1500 1625 1725

6 1200 1050 1075 1140

8 900 - 825 850

HORSEPOWER & STACK LENGTHS:

4 & 6 POLE OPEN MOTORS

8 POLE OPEN MOTORS

HPAPPROX.

STACK LENGTHHP

APPROX. STACK LENGTH

1/4 1.25” 1/8 1.13”

1/3 1.50” 1/6 1.25”

1/2 2.25” 1/4 1.62”

3/4 2.50” 1/3 2.25”

4 & 6 POLE OPEN MOTORS

8 POLE CLOSED MOTORS

HPAPPROX. STACK

LENGTHHP

APPROX. STACK LENGTH

1/4 1.25” 1/8 1.25”

1/3 1.75” 1/6 1.38”

1/2 2.50” 1/4 1.75”

3/4 3.00” 1/3 2.50”

VOLTAGE: COMMON VOLTAGE

115 230 DUAL 277 460 575

SP X X - X - -

PSC X X - X X -

SPLIT PH X X - - - -

CAP START X X 115/230 - - -

3 PHASE - X 230/460 - X X

NOTE: Voltage may be difficult to determine. ASK THE CUSTOMER!

COUNT # OF POLES

MEASURE STACK HEIGHT FOR HP

SOME RULES OF THUMB: GENERALLY IF THIS IS...

THE ORIGINALTHIS CAN BE USED

AS A REPLACEMENT

SHADED POLEPERMANENT SPLIT

CAPACITOR BALL BEARING

SLEEVE BEARINGS SLEEVE BEARING TOTALLY

OPEN OR DP ENCLOSED

1 SPEED 1, 2 OR 3 SPEED

2 SPEED 2 OR 3 SPEED

370 VOLT CAPACITOR

370 OR 460 VOLT CAPACITOR

1

23

4

5

6

Page 7: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 5

FAST DIRECT DRIVE BLOWER MOTORS

FAST PARTS DIRECT DRIVE BLOWER MOTORS

• 3 Speeds, Electrically reversible

• Continuous Air Over 40°C

• Ambient Design

• All Angle Sleeve Bearings

• Extended Thru Bolt

• Automatic Reset Thermal Overload Protector

• 2 1/4” Resilient Rings

• Single Phase, 60 HZ

• Class B insulation

• NEMA Frame 48

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3583 1/4 115 3.8 1075/3 SAB 60 9.4 4.3 1/2" X 4" 10/370 F87071003

F257-3585 1/3 115 5.0 1075/3 SAB 60 9.7 4.6 1/2" X 4" 10/370 F87071003

F257-3587 1/2 115 6.0 1075/3 SAB 60 10.2 5.1 1/2" X 4" 10/370 F87071003

F257-3589 3/4 115 9.5 1075/3 SAB 60 10.7 5.6 1/2" X 4" 15/370 F87071503

F257-3584 1/4 208-230 1.6 1075/3 SAB 60 9.4 4.3 1/2" X 4" 10/370 F87071003

F257-3586 1/3 208-230 2.2 1075/3 SAB 60 9.7 4.6 1/2" X 4" 10/370 F87071003

F257-3588 1/2 208-230 2.7 1075/3 SAB 60 10.4 5.3 1/2" X 4" 10/370 F87071003

F257-3590 3/4 208-230 4.0 1075/3 SAB 60 10.7 5.6 1/2" X 4" 15/370 F87071503

FAST Parts Direct Drive Blower Motors are three speed standard efficiency, reversible rotation with extended thru bolts and resilient rings for base mounting. These models have open air enclosures and feature shell mounting holes for universal replacement of non-ventilated motors for exhaust, air circulators, unit heaters, unit coolers, and other air-over applications.

STANDARD EFFICIENCY

MULTI-HORSEPOWER

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3463 1/2-1/6 115 7.3 1075/4 SAB 60 10.4 4.9 1/2" X 5" 10/370 F87071003

F257-3466 3/4-1/5 115 8.1 1075/4 SAB 60 12.2 6.1 1/2" X 5" 20/370 F87072003

F257-3464 1/2-1/6 208-230 3.6 1075/4 SAB 60 10.4 4.9 1/2" X 5" 10/370 F87071003

F257-3467 3/4-1/5 208-230 3.8 1075/4 SAB 60 12.2 6.1 1/2" X 5" 20/370 F87072003

DIR

EC

T D

RIV

E B

LO

WE

R M

OT

OR

S

Page 8: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

1 | Aftermarket Motor & Accesories Guide6 | Aftermarket Motor & Accessories Guide

FAST CONDENSER FAN MOTORS

CO

ND

EN

SO

R F

AN

MO

TO

RS

FAST PARTS CONDENSER FAN MOTORS TOTALLY ENCLOSED - ALL POSITION MOUNTING

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3727 1/6 208-230 1.2 1075/1 BALL 60 10.6 4.1 1/2" X 6" 10/370 F87071003

F257-3728 1/4 208-230 1.4 1075/1 BALL 60 10.9 4.3 1/2" X 6" 5/370 F87070503

F257-3729 1/3 208-230 2.0 1075/1 BALL 60 11.4 4.8 1/2" X 6" 7.5/370 F87070753

F257-3730 1/2 208-230 3.0 1075/1 BALL 60 11.6 5.6 1/2" X 6" 10/370 F87071003

F257-3731 3/4 208-230 3.9 1075/1 BALL 60 12.8 5.8 1/2" X 6" 15/370 F87071503

F257-3203 1/6 208-230 1.0 825/1 BALL 6.0 10.6 4.1 1/2" X 6" 5/370 F87070503

F257-3204 1/4 208-230 2.0 825/1 BALL 60 10.9 4.3 1/2" X 6" 5/370 F87070503

F257-3205 1/3 208-230 2.4 825/1 BALL 60 11.0 4.5 1/2" X 6" 7.5/440 F87070754

F257-3206 1/2 208-230 2.8 825/1 BALL 60 12.4 5.8 1/2" X 6" 10/370 F87071003

FAST Parts Condenser Fan Motors are designed as a universal PSC replacement for vertical shaft- up or shaft-down applications. Shell and end shields are closed for protection against weather. All FAST Parts Condenser Fan Motors feature reversible rotation and thru bolt or band mounting for air conditioning or heat pump applications. • 5.6” Diameter, Totally

Enclosed Air Over TEAO • 60°C (140°F) Ambient

Design• Ball Bearings • Extended Studs,

All Angle Mount • 30” Leads • Rheem shell

mounting holes

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3465 1/3-1/6 208-230 2.6 1075/2 BALL 60 9.6 4.6 1/2" X 5" 5/370 F87070503

F257-3468 1/2-1/5 208-230 3.0 1075/2 BALL 60 10.3 5.3 1/2" X 5" 10/370 F87071003

F257-3469 1/3-1/6 208-230 1.9 825/2 BALL 60 10.3 5.3 1/2" X 5" 7.5/370 F87070753

• Reversible Rotation• Automatic Reset

Thermal Overload Protector

• Continuous Duty • Single Phase, 60 HZ • Class B Insulation • NEMA Frame 48

MULTI-HORSEPOWER

Page 9: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASThvacparts.com® | 1www.FASTHVACRparts.com | 7

FAST CONDENSER FAN MOTORS

FAST PARTS HIGH TEMPERATURE CONDENSER FAN MOTORS 70 °C

• Totally Enclosed Air Over TEAO

• 48” Leads, Extended Studs, 5.6” Diameter

• Drain Holes Both Ends

• Hubless Lead End

• Reversible Rotation

• Automatic Reset Thermal Overload Protector

• Continuous Duty

• Single Phase, 60 HZ

• Class F insulation

• NEMA Frame 48

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3726HS 1/6 208-230 1.0 1075/1 BALL 60 10.4 3.8 1/2" X 6" 5/370 F87070503

F257-3732HS 1/4 208-230 1.5 1075/1 BALL 60 11.6 4.6 1/2" X 6" 5/370 F87070503

F257-3733HS 1/3 208-230 1.8 1075/1 BALL 60 12.1 5.1 1/2" X 6" 7.5/370 F87070753

F257-3734HS 1/2 208-230 3.3 1075/1 BALL 60 12.3 5.8 1/2" X 6" 10/370 F87071003

F257-3735HS 3/4 208-230 4.7 1075/1 BALL 60 12.4 5.8 1/2" X 6" 10/370 F87071003

F257-3204H 1/4 208-230 2.1 825/1 BALL 60 10.9 4.3 1/2" X 6" 5/370 F87070503

F257-3205H 1/3 208-230 2.4 825/1 BALL 60 11.6 5.1 1/2" X 6" 7.5/370 F87070754

FAST Parts High Temperature Condenser Fan Motors feature 70°C (158°F) Ambient Design. All angle mounting position for universal versatility.

MULTI-HORSEPOWER

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3458HS 1/3-1/6 208-230 2.0 1075/1 BALL 60 10.9 4.3 6.0 7.5/370 F87070753

F257-3459HS 1/3-1/5 208-230 2.4 825/1 BALL 60 11.6 5.1 6.0 7.5/440 F87070754

PART HP VOLTAGE AMPS RPM BRGS HZDIM

TOTALDIM

BODYSHAFT DIA & LENGTH (IN)

CAP CAP PART

F257-3736HS 1/4 460 0.8 1075/1 BALL 60 111.1 4.6 6.0 7.5/370 F87070753

F257-3737HS 1/3 460 1.0 1075/1 BALL 60 11.6 5.1 6.0 7.5/370 F87070753

F257-3738HS 1/2 460 1.5 1075/1 BALL 60 12.0 5.3 6.0 10/370 F87071003

F257-3739HS 3/4 460 2.0 1075/1 BALL 60 12.9 6.3 6.0 10/370 F87071003

CO

ND

EN

SO

R F

AN

MO

TO

RS

460V

Page 10: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

8 | Aftermarket Motor & Accessories Guide

DIRECT DRIVE BLOWER MOTORS

NIDEC® PERMANENT SPLIT CAPACITOR DIRECT DRIVE FAN AND BLOWER

FEATURES:• Frame: 48

• Class B Insulation

• 24” Leads

• Continuous Duty, Air Over

• Reversible Rotation

• Suitable for Use with 370V Capacitors

• Automatic Reset Thermal Overload Protector

*Includes Rheem Mount Holes

PART HP RPM VOLTAGE AMPSSHAFT

NBASE

XDSHELL

XITOTAL

CSHIP WT.

LBS.

1390 1/4 1050/3 115 2.8 4.0 4.9 4.3 8.9 13

1863 1/4 1075/3 115 3.5 5.0 4.9 4.3 10.4 12

1971 1/4 1075/3 208-230 1.5 5.0 4.9 4.3 10.4 11

1864 1/3 1075/3 115 5.0 5.0 5.1 4.6 10.7 12

1972 1/3 1075/3 208-230 1.9 5.0 4.9 4.6 10.7 13

1865 1/2 1075/3 115 6.5 4.0 6.0 5.4 10.4 19

1973 1/2 1075/3 208-230 2.9 5.0 5.9 5.3 11.4 19

5460* 1/2 1075/2 115 7.3 5.0 5.4 4.8 9.8 12

5461* 1/2- 1/6 1075/2 208-230 3.6 5.0 5.4 4.8 9.8 15

8904 3/4 1075/3 115 9.5 4.0 6.0 5.4 10.4 19

8905 3/4 1075/3 208-230 4.0 4.0 6.0 5.4 10.4 19

5470 3/4 - 1/5 1075/2 115 8.1 5.0 6.6 6.1 11.6 22

5471 3/4 - 1/5 1075/2 208-230 4.1 5.0 6.6 6.1 11.6 21

5846 3/4 1075/4 208-230 6.1-5.8 5.25 6.65 6.17 13.2 19

DIR

EC

T D

RIV

E B

LO

WE

R M

OTO

RS

Page 11: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

DIR

EC

T D

RIV

E B

LO

WE

R M

OT

OR

S

www.FASTHVACRparts.com | 9

DIRECT DRIVE BLOWER MOTORS

NIDEC PERMANENT SPLIT CAPACITOR DIRECT DRIVE FAN AND BLOWER

FEATURES:• Frame: 42

• 5.0” Diameter Stud or HubRing Mount (2.5”)

• Non-Reversible

• Rotation CCWLE

PART HP RPM VOLTAGE AMPSSHAFT

NBASE

XDSHELL

XITOTAL

CSHIP WT.

LBS.

1342* 1/15 1050/1 115 2.6 2.8 -- 3.8 6.6 10

2166P 1/6 1050/1 115 5.2 3.5 4.5 3.8 8.9 10

1268NM 1/5 1075/4 115 3.4 3.5 4.6 4.1 8.7 10

*Conduit Box on Motor

NIDEC SHADED POLE FLEX MOUNT DIRECT DRIVE FAN AND BLOWER

FEATURES:• Frame: 42

• Class B Insulation

• 5.8” Diameter motorsCWLE Rotation

• Bearings Have AllAngle Thrust System

• Continuous Duty, Air Over

• 24” Leads

PART HP RPM VOLTAGE AMPSSHAFT

NSHAFT

XITOTAL

CSHIP WT.

LBS.

2867P 1/5 1050/1 115 3.0 3.8 4.5 8.300 10

Page 12: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

10 | Aftermarket Motor & Accessories Guide

CONDENSER FAN MOTORS

NIDEC® PERMANENT SPLIT CAPACITOR CONDENSER FAN TOTALLY ENCLOSED AIR OVER

FEATURES:• Frame: 48

• 60˚C Ambient

• Sleeve Bearings

• Class B Insulation

• Extended Studs

• Hubless Lead End

• Drain Holes Both Ends

• Reversible Rotation

• Automatic Reset Thermal Overload Protector

• Continuous Duty

PART HP RPM VOLTAGE AMPSSHAFT

NSHELL

XITOTAL

CSHIP WT.

LBS.

1873 1/6 825 208-230 1.00 6 4.1 10.6 12

1859 1/6 1075 208-230 1.0 5 3.8 9.4 11

1874 1/4 1/8 825 208-230 2.0 6 4.3 10.9 13

1875 1/3 1/5 825 208-230 2.4-1.4 6 5.1 11.6 17

1861 1/3 1130 208-230 2.0 5 4.6 10.1 14

1881 1/3 825 460 1.0 6 5.6 12.1 17

1862 1/2 1075 208-230 3.1 6 5.3 11.9 18

1868 3/4 1075 208-230 4.7 5 5.8 10.3 20

3738 1/2 1115 460 1.5 6 5.9 12.4 19

3742 3/4 1075 460 2.0 6 6.4 12.9 22

NIDEC® PERMANENT SPLIT CAPACITOR CONDENSER FAN 5.6” DIAMETER

FEATURES:• 60 Hertz

• Continuous Duty, Air Over

• Water Slinger

• Suitable for use with 370V Capacitor

PART HP RPM VOLTAGE AMPSSHAFT

NBASE

XDSHELL

XITOTAL

CSHIP WT.

LBS.

8666 1/4 825 230 1.9 6.0 5.1 4.6 11.6 14

3851 1/4 1075 208-230 1.7 5.0 4.4 3.8 9.9 14

6880 1/3 1075 208-230 2.5-2.2 5.0 4.9 4.3 9.4 12

3852 1/2 1075 208-230 3.1 5.0 5.4 4.8 10.9 15

• Automatic Reset Thermal Overload Protector

• Reversible Rotation

• Class B Insulation

• 30” Leads

• Double Flats on Shaft

CO

ND

EN

SE

R F

AN

MO

TO

RS

Page 13: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 11

CO

ND

EN

SE

R F

AN

MO

TO

RS

CONDENSER FAN MOTORS

PSC CONDENSER FAN HIGH TEMP NIDEC® MOJAVE SERIES

FEATURES:• 158˚F (70˚C) Ambient Design

• Totally Enclosed Air Over (TEAO)

• Ball Bearings

• Class F Insulation

• Suitable for use with 370V Capacitors

• Extended Studs

• 48” Leads

• 5.6” Diameter

• Hubless Lead End

• Drain Holes Both Ends

• Reversible Rotation

• Automatic Reset Thermal Overlead Protector

• Continuous Duty

PART HP RPM VOLTAGE BEARINGSCAP MFD

AMPSSHAFT

NSHELL

XITOTAL

CSHIP WT.

LBS.

1874H 1/4 - 1/8 825 208-230 BALL 5.0 2.1 6.0 4.4 10.9 13.0

1860H 1/4 1075 208-230 BALL 5.0 1.7 6.0 4.1 10.6 12.0

1861H 1/3 1075 208-230 BALL 7.5 2.1 6.0 4.6 11.1 14.0

1862H 1/2 1075 208-230 BALL 10.0 3.2 6.0 5.3 11.9 18.0

1868H 3/4 1075 208-230 BALL 10.0 4.7 6.0 5.8 12.4 20.0

SHADED POLE UNIT BEARING, TOTALLY ENCLOSED

FEATURES:• Suitable for All Angle Operation

• Cast Iron Housing

• Permanently Lubricated Bearings

• CWLE Rotation

• For Refrigerated Display Cases and Vending Machines

PART HP RPM VOLTAGE AMPSSHAFT DIA.& LENGTH

SHIP WT.LBS.

INDUSTRYNUMBER

2108 9 W 1550 115 0.6 1/4 x 20 THD x 0.5 3 5411

2110 9 W 1550 230 0.3 1/4 x 20 THD x 0.6 5 5421

2125 25 W 1550 115 1.1 1/4 x 20 THD x 0.7 5 ESPL25EM1

Page 14: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

12 | Aftermarket Motor & Accessories Guide

CONDENSER FAN MOTORS

CO

ND

EN

SE

R F

AN

MO

TO

RS

PERMANENT SPLIT CAPACITOR CONDENSER FAN RESCUE® MOTORS

FEATURES:• Frame:48

• 5.6” Diameter, Totally Enclosed, Air Over

• Suitable for Use with 370V Capacitors

• Includes Lead End Mounting Holes for Rheem or Trane Units

• 48” Leads

• Extended Mounting Studs

• Ball Bearings

• Reversible Rotation

• High Efficiency Design

PART HP RPM VOLTAGE AMBIENTCAP MFD @208V

CAP MFD @230V

AMPSSHAFT

NSHELL

XITOTAL

CSHIP

WT. LBS.

5464 1/6-1/3 825 208/230 60°C 10 7.5 1.0-1.9 5 5.3 10.3 18

5464H 1/6-1/3 825 208/230 70°C 10 7.5 1.0-1.9 5 5.3 10.3 18

5462 1/6-1/3 1075 208/230 60°C 7.5 5 1.8-2.6 5 4.6 9.6 15

5462H 1/6-1/3 1075 208/230 70°C 7.5 5 1.8-2.6 5 4.6 9.6 18.10

5465 1/6-1/3 1075 208/230 60°C 12.5 10 1.3-3.0 5 5.3 10.3 19

RESCUE® MOTORS, 48 FRAME CONDENSER FAN MOTORS, 460 VOLT

PART HP RPM VOLTAGE AMBIENTCAP MFD

AMPS SHAFT NSHELL

XITOTAL C

SHIP WT. LBS.

5481H 1/4-3/4 1075 460 70°C 15 0.7-2.2 5 6.3 11.9 22.38

RESCUE® MOTORS 42 FRAME CONDENSER FAN MOTOR

• 5.0” Diameter• Totally Enclosed Air Over

PART HP RPM VOLTAGE AMBIENT AMPS BEARINGSSHIP WT.

LBS.

5440H 1/12-1/8 1075 208-230 70°C 0.8 BALL 10

5441H 1/6-1/4 1075 208-230 60°C 1.5 BALL 10

Page 15: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

GENERIC REPLACEMENT MOTORS

GE

NE

RIC

RE

PL

AC

EM

EN

T M

OT

OR

S

www.FASTHVACRparts.com | 13

FEATURES:• Replaces X13 or Endura Pro• Replaces competitive OEM’s Direct-Drive blower

motors designed with X13 or equivalent competitive model constant torque standard ECM with 24vac speed taps

• Available in 1/3, 1/2, 3/4 and 1HP ratings

• 115V, 208-230V or 277V single phase, 50/60 Hz, 1070rpm

• Pre-Programmed - 5 discrete speeds using 24VAC

• Permanently lubricated ball bearings

• Frame: 48, UL and CSA recognized

• Automatic Dual Rotation

• Two Year Warranty

DOES NOT REPLACE MODELS 2.3, Eon, 2.5, 3.0 or 142®

EVERGREEN® EM X13 AFTERMARKET REPLACEMENT MOTORS

PART HP VOLTAGE MAX CURRENT ROTATION DIM. A DIM. B WEIGHT

6103E 1/3 115 4.8 A CCW/CW 10.17” 5.25” 8.4

6105E 1/2 115 6.8 A CCW/CW 10.67” 5.75” 11.3

6107E 3/4 115 8.4 A CCW/CW 11.42” 6.5” 15.6

6110E 1 115 10.9 A CCW/CW 12.17” 7.25” 19.3

6203E 1/3 208-230 2.8 A CCW/CW 10.17” 5.25” 8.4

6205E 1/2 208-230 4.1 A CCW/CW 10.67” 5.75” 11.3

6207E 3/4 208-230 6.0 A CCW/CW 11.42” 6.5” 15.6

6210E 1 208-230 7.6 A CCW/CW 12.17” 7.25” 19.3

6703 1/3 208-230/277V 2.8 A CCW/CW 9.17” 5.25” 8.3

6705 1/2 208-230/277V 4.1 A CCW/CW 9.67” 5.75” 11.3

6707 3/4 208-230/277V 6.0 A CCW/CW 10.42” 6.5” 15.5

Page 16: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

14 | Aftermarket Motor & Accessories Guide

GENERIC REPLACEMENT MOTORS

GE

NE

RIC

RE

PL

AC

EM

EN

T M

OTO

RS

FEATURES:• Replaces competitive OEM's Direct-Drive Blower motors designed

with a 6-pole 1075rpm rated PSC motor.

• 2 Multi-HP Models Available: 1/2HP (1/5 - 1/2) and 1HP rating (1/2 - 1)

• Dual voltage 115/230V single-phase input, 50/60Hz

• 4 discrete speeds using 24VAC, plus automatic continuous fan speed, efficiency up to 80%

• Frame: 48, UL and CSA recognized

• Automatic Dual Rotation

• Two Year Warranty

DOES NOT REPLACE ANY EXISTING ECM

EVERGREEN® IM AFTERMARKET PSC REPLACEMENT

PART HP VOLT. MAX CURR. ROT. DIM A DIM B WT.

6005 1/2 115/230 6.7/4.0 A CCW/CW 11.26” 6.34” 12

6010 1 115/230 11.0/6.7 A CCW/CW 12.76” 7.84” 20

EVERGREEN® MOUNTING KITS

5K003 10"Kit includes motor support, grommetcenters, grommet

rings, sleeve spacers, bolts, nuts and washers5K004 11"

5K005 13"

Page 17: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 15

GENERAL PURPOSE MOTORS

FEATURES:• 5.6 Diameter

• Open Dripproof, Air Over

• Multi-Speed

• Hub or Stud Mount, Hub Rings are 2 1/4" Diameter, Furnished Detached with ExtraMetal Rings for Adapting to 2 1/2" Diameter

• CCW Rotation Lead End

• 40°C Ambient, 60 HZ

• Class B Insulation

NIDEC® DOUBLE SHAFT FAN MOTORS PERMANENT SPLIT CAPACITOR DOUBLE SHAFT FAN & BLOWER

PART HP VOLTAGE RPM AMPS ROTTHERMAL

OVERLOAD PROTECTOR

SHAFT N

SHAFT XN

SHELL XL

TO-TAL 0

SHIP WT.

NAL1016 1/6 115 1075/3 2.4 CCW LE AUTO 10 6.75 5.625 22.0 10

NA1016 1/6 208-230 1075/3 2.6 CCW LE AUTO 9 6.75 5.625 22.0 9

NA3134 1/4 208-230 1075/3 3.1 CCW LE AUTO 11 6.75 5.625 22.0 11

NA3135 1/3 208-230 1075/3 CCW LE AUTO 14 6.75 5.625 22.0 14

NA3136 1/2 208-230 1075/3 CCW LE 5.25” 16 6.75 5.625 22.0 16

GE

NE

RA

L P

UR

PO

SE

MO

TO

RS

Page 18: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

16 | Aftermarket Motor & Accessories Guide

GE

NE

RA

L P

UR

PO

SE

MO

TO

RS

GENERAL PURPOSE MOTORS

NIDEC® GENERAL PURPOSE SINGLE PHASE

FEATURES:• Frame: 56

• Open Drip Proof (ODP) Split Phase

• 40˚C Ambient

• 60 Hertz

• Reversible Rotation

• Continuous Duty

• Class A or B Insulation

PART HP RPM VOLTAGE BEARINGS AMPSSHAFT DIA.

(IN)LENGTH (IN)

SHIP WT.LBS.

D34B2N9 3/4 1800 115 BALL 11 0.625 11.28 21

3754 1 1800 115/208-230 BALL 16.4/8.2 0.625 11.76 32

NIDEC® GENERAL PURPOSE THREE PHASE

FEATURES:• Class F Insulation

• 40°C Ambient

• Regreasable Bearings

PART HP RPM VOLTAGE FRAMEFULL LOAD

EFFFULL LOAD

AMPSSHIP WT.

LBS.

D2S2AH 2 1800 208-230/460 56H 84.0 6.1-6.2/3.1 35

D3E2D 3 1800 208-230/460 182T 89.5 8.4-7.8/3.9 50

D5E2D 5 1800 208-230/460 184T 89.5 13.8-13/6.5 115

D7E2D 7.5 1800 208-230/460 213T 91.0 20.2-18.5/9.3 105

#D34B2N9 #3754

Page 19: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 17

BELTED BLOWER MOTORS

BE

LTE

D B

LO

WE

R M

OTO

R

NIDEC® SPLIT PHASE BELTED FAN AND BLOWER

FEATURES:• Resilient Base

• Class B Insulation

• Threaded Conduit Hole

• Reversible Rotation

• Automatic Reset Thermal Overload Protector

PART HP RPM VOLTAGE FRAME BEARINGS AMPSSHAFT

NSHAFT

UTOTAL

CSHIP

WT. LBS.

PD6006 1/2 1725 115/208/231 48Z BALL 8.6/4.2-4.3 1.9 0.500 10.7 20

8000 1/4 1725 115Combo Mounting Holes for 48 & 56

BALL 5.3 1.5 0.500 8.9 13

8100 1/3 1725 115Combo Mounting Holes for 48 & 56

BALL 6.4 1.5 0.500 9.4 15

8200 1/2 1725 115Combo Mounting Holes for 48 & 56

BALL 8.0 1.5 0.500 10.0 18

4242 1 1/2 1725115/208-

23056 BALL 22.4/11.2 1.9 0.625 12.8 35

NIDEC CAPACITOR START BELTED BLOWER OPEN DRIP-PROOF, RESILIENT BASE

FEATURES:• 40°C Ambient

• Class A Insulation

• Reversible Rotation

• Suitable for All Angle

• Automatic Reset Thermal

• Overload Protector

• Threaded Conduit Hole

PART HP VOLTAGE RPM AMPS ROTTHERMAL OVERLOAD

PROTECTORCLASS

SHAFT N

SHAFT U

TOTAL C

SHIP WT.

1790 1/2 115/208-230 1725 2.4 REV AUTO A 1.9 .625 9.3 22

1893 3/4 115/208-230 1725 2.6 REV AUTO A 1.9 .0625 10.8 27

1769 1 115/208-230 1725 3.1 REV AUTO A 1,9 .625 11.8 29

Page 20: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

18 | Aftermarket Motor & Accessories Guide

OIL BURNER MOTORS

OIL

BU

RN

ER

MO

TO

RS

NIDEC OIL BURNER MOTORS (60 HERTZ) SINGLE PHASE

*Motor leads - 21 inches long, 18 gauge. **Motor leads -24” long #18 50 2-conductor out shell at 11 o’clock position.

FEATURES:• 40°C Ambient

• 20" Leads, Located at 3 O'clock Viewed From End Opposite Shaft

• 48M and 48N Flange Are Ventilated

• Bearings Have All Angle Thrust System

• Ball Bearings

• NEMA Frame 48N

PART HP VOLT RPM AMPS ROTTHERMAL

OVERLOAD PROTECTOR

CLASSSHAFT

NSHAFT

UTOTAL

CSHIP WT.

NOTE

3196 1/8 115 1725 2.4 REV MANUAL A 2.0 0.500 7.6 14REMOVABLE FACE PLATE

3083 1/7 115 3450 2.6 REV MANUAL F 2.0 0.500 7.3 11

3252EM 1/6 115 1725 3.1 REV MANUAL B 2.0 0.500 7.6 15

3274 1/7 115 3450 1.7NON-REV

AUTO F 2.0 0.500 7.2 11

3.7" BODY, PSC MOTOR CAPACITOR INCLUDED

Page 21: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 19

COMMERCIAL MOTORS

FEATURES:• Frame: 56

• Automatic Reset Thermal Overload Protector

• Reversible Rotation

• Continuous Duty Air Over

• Double-Sealed Ball Bearings

• Dual Voltage

• Class B Insulation

• 60˚C Ambient Rating

• Shaft Up Mounting

PART HP RPM VOLTAGE AMPSSHAFT

NSHAFT

UTOTAL

CSHIP WT.

LBS.

1818 1 1140 208-230/460 4.0/2.0 6 0.625 16.8 29

1828 1 850 208-230/460 5.0/2.5 6 0.625 17.2 33

1819 1 1/2 1140 208-230/460 6.2/3.1 6 0.625 16.8 36

NIDEC COMMERCIAL THREE-PHASE CONDENSER FAN MOTORS

FEATURES:• Frame: 56

• Open Air Over

• Shaft Up

• 70˚C Ambient

• Rigid Base Mount

• Class F Insulation

PART HP RPM VOLTAGE AMPS SHIP WT.

1820H 1 1140 208-230/460 4.2/2.1 27

CO

MM

ER

CIA

L

MO

TO

RS

Page 22: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

20 | Aftermarket Motor & Accessories Guide

COMMERCIAL MOTORS

F2 MOUNT - FOOT MOUNTED

WITH SHAFT GROUNDING RING INSTALLED INTERNALLY (CLASS H MOTOR)

PART HP VOLTAGE PH RPM ENCL FRAME

EM3116T 1 230, 460 3 1800 ODP 143T

EM3154T 1.5 230, 460 3 1800 ODP 145T

EM3154T-5 1.5 575 3 1800 ODP 145T

EM3157T 2 230, 460 3 1800 ODP 145T

EM3211T 3 230, 460 3 1800 ODP 182T

EM3218T 5 230, 460 3 1800 ODP 184T

EM3218T-8 5 230, 460 3 1800 ODP 184T

EM3311T 7.5 230, 460 3 1800 ODP 213T

EM3311T-8 7.5 200 3 1800 ODP 213T

EM3313T 10 230, 460 3 1800 ODP 215T

EM2513T 15 230, 460 3 1800 ODP 254T

EM2515T 20 230, 460 3 1800 ODP 256T

EM2531T 25 230, 460 3 1800 ODP 284T

EM2535T 30 230, 460 3 1800 ODP 286T

EM2536T 30 230, 460 3 1800 ODP 326T

EM2539T 40 230, 460 3 1800 ODP 324T

BALDOR® HVAC INTEGRAL MOTORS GENERAL PURPOSE, THREE PHASE ODP

PART HP VOLTAGE PH RPM ENCL FRAME

EM3211T-G 3 230, 460 3 1800 ODP 182T

EM3218T-G 5 230, 460 3 1800 ODP 184T

EM2513T-G 15 230, 460 3 1800 ODP 254T

EM2539T-G 40 230, 460 3 1800 ODP 324T

PART HP VOLTAGE PH RPM ENCL FRAME

EFM2513T 15 230/460 3 1800 ODP 254T

EFM2515T 20 230/460 3 1800 ODP 256T

EFM3211T 3 230/460 3 1800 ODP 182T

EFM3218T 5 208-230/460 3 1800 ODP 184T

EFM3311T 7.5 230/460 3 1800 ODP 213T

EFM3313T 10 230/460 3 1800 ODP 215T

FEATURES:• Heavy Gauge Steel Frame Construction • Balanced Rotors for Reduced Vibration and Quiet Operation • Suitable Mounting For Any Position • Available in 1-75 HP - ask us for a quote • Made in USA

CO

MM

ER

CIA

L M

OTO

RS

Page 23: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 21

COMMERCIAL MOTORS

F2 MOUNT - FOOT MOUNTED

WITH SHAFT GROUNDING RING INSTALLED INTERNALLY (CLASS H MOTOR)

PART HP VOLTAGE PH RPM ENCL FRAME

EM3546T 1 230, 460 3 1800 TEFC 143T

EM3554T 1.5 230, 460 3 1800 TEFC 145T

EM3558T 2 230, 460 3 1800 TEFC 145T

EM3611T 3 230, 460 3 1800 TEFC 182T

EM3615T 5 230, 460 3 1800 TEFC 184T

EM3710T 7.5 230, 460 3 1800 TEFC 213T

EM3714T 10 230, 460 3 1800 TEFC 215T

EM2333T 15 230, 460 3 1800 TEFC 254T

EM2334T 20 230, 460 3 1800 TEFC 256T

EM4103T 25 230, 460 3 1800 TEFC 284T

EM4104T 30 230, 460 3 1800 TEFC 286T

EM4110T 40 230, 460 3 1800 TEFC 324T

BALDOR® HVAC INTEGRAL MOTORS GENERAL PURPOSE, THREE PHASE TEFC

FEATURES:• Energy saving applications where continuous operation is required

• Suitable for use with inverter drives for variable torque and constant torque ratings.

• Class F Insulation

• Low-loss electrical grade lamination steel

• Made in USA

PART HP VOLTAGE PH RPM ENCL FRAME

EM3546T-G 1 230, 460 3 1800 TEFC 143T

EM3615T-G 5 230, 460 3 1800 TEFC 184T

PART HP VOLTAGE PH RPM ENCL FRAME

EFM3611T 3 208-230/460 3 1800 TEFC 182T

EFM3615T 5 208-230/460 3 1800 TEFC 184T

EFM3710T 7.5 208-230/460 3 1800 TEFC 213T

CO

MM

ER

CIA

L

MO

TO

RS

Page 24: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

22 | Aftermarket Motor & Accessories Guide

COMMERCIAL MOTORS

PART HP VOLTAGE PH RPM ENCL FRAME

34H777X488 1 230, 460 3 1800 ODP 56

HM9214T 1.5 208-230, 460 3 1800 ODP 145T

HM9218T 2 208-230, 460 3 1800 ODP 145T

HM MODELS MEET EPACT EFFICIENCIES

H3M AND EH3M MOTORS USE LOW PROFILE TOP-MOUNTED CONDUIT BOX

BALDOR® HVAC INTEGRAL MOTORS VARIABLE TORQUE, THREE PHASE, ODP

FEATURES:• Heavy-guage steel frame

construction• Dynamically balanced rotors for

reduced vibration• Suitable for mounting in

any position• HM models meet EPAct

efficiencies• H3M and EH3M motors use low

profile top-mounted conduit box• EHM models are above EPAct

efficiency, but do not meet NEMA Premium efficiencies

• Made in USA

EHM MODELS ARE ABOVE EPACT EFFICIENCY, BUT DO NOT MEET NEMA PREMIUM EFFICIENCIES

PART HP VOLTAGE PH RPM ENCL FRAME

EHM2515T 20 208-230, 460 3 1800 ODP 256T

EHM2523T 15 208-230, 460 3 1800 ODP 254T

EHM3211T 3 208-230, 460 3 1800 ODP 182T

EHM3218T 5 208-230, 460 3 1800 ODP 184T

EHM9214T 1.5 208-230, 460 3 1800 ODP 145T

PART HP VOLTAGE PH RPM ENCL FRAME

H3M9218T 2 208-230, 460 3 1800 ODP 145T

H3M9221T 3 208-230, 460 3 3600 ODP 145T

H3M9122T 3 208-230, 460 3 1800 ODP 182T

H3M9225T 5 208-230, 460 3 3600 ODP 182T

H3M9232T 10 208-230, 460 3 1800 ODP 215T

H3M9135T 15 208-230, 460 3 1800 ODP 254T

H3M9233T 15 208-230, 460 3 3600 ODP 215T

EH3M9214T 1.5 230, 460 3 1800 ODP 145T

EH3M9221T 3 230, 460 3 3600 ODP 145T

EH3M9122T 3 230, 460 3 1800 TEFC 182T

EH3M9125T 5 208-230, 460 3 3600 TEFC 184T

EH3M9126T 5 230, 460 3 1800 TEFC 184T

EH3M9128T 7.5 230, 460 3 3600 TEFC 213Y

EH3M9129T 7.5 230, 460 3 1800 TEFC 213T

EH3M9135T 15 230, 460 3 1800 TEFC 254T

35W928Q056G1 5 230, 460 3 3600 ODP 182T

EH3M9229T 7.5 230, 460 3 3600 ODP 184T

EH3M9229T 7.5 230, 460 3 1800 ODP 213T

EH3M9232T 10 230, 460 3 1800 ODP 215T

EH3M9235T 15 230, 460 3 1760 ODP 254T

CO

MM

ER

CIA

L M

OTO

RS

Page 25: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 23

FR

AC

TIO

NA

L H

P V

-BE

LTS

FAST FAN BELTS

FAST® FHP V-Belts are built for maximum tension control, drive uniformity and long life, with minimum heat build-up and stretching on low horsepower electric motors and gasoline engines. They are designed for high speed operation and drive center distances as short as pulleys will allow.

PARTOUTSIDE LENGTH

(IN)

F14043L150 15

F14043L160 16

F14043L170 17

F14043L180 18

F14043L190 19

F14043L200 20

F14043L210 21

F14043L220 22

F14043L230 23

F14043L240 24

F14043L250 25

F14043L260 26

F14043L270 27

PARTOUTSIDE LENGTH

(IN)

F14044L170 17

F14044L180 18

F14044L190 19

F14044L200 20

F14044L210 21

F14044L220 22

F14044L230 23

F14044L240 24

F14044L250 25

F14044L260 26

F14044L270 27

F14044L280 28

F14044L290 29

F14044L300 30

F14044L310 31

F14044L320 32

F14044L330 33

F14044L340 34

F14044L350 35

F14044L360 36

F14044L370 37

PARTOUTSIDE LENGTH

(IN)

F14044L380 38

F14044L390 39

F14044L400 40

F14044L410 41

F14044L420 42

F14044L430 43

F14044L440 44

F14044L450 45

F14044L460 46

F14044L470 47

F14044L480 48

F14044L490 49

F14044L500 50

F14044L510 51

F14044L520 52

F14044L530 53

F14044L540 54

F14044L550 55

F14044L560 56

F14044L570 57

F14044L580 58

3L SIZES

4L SIZES

PARTOUTSIDE LENGTH

(IN)

F14043L280 28

F14043L290 29

F14043L300 30

F14043L310 31

F14043L320 32

F14043L330 33

F14043L340 34

F14043L350 35

F14043L360 36

F14043L370 37

F14043L380 38

F14043L390 39

PARTOUTSIDE LENGTH

(IN)

F14044L590 59

F14044L600 60

F14044L610 61

F14044L620 62

F14044L630 63

F14044L640 64

F14044L650 65

F14044L660 66

F14044L670 67

F14044L680 68

F14044L690 69

F14044L700 70

F14044L710 71

F14044L720 72

F14044L730 73

F14044L740 74

F14044L750 75

F14044L760 76

F14044L770 77

F14044L780 78

F14044L790 79

PARTOUTSIDE LENGTH

(IN)

F14043L400 40

F14043L410 41

F14043L420 42

F14043L430 43

F14043L440 44

F14043L450 45

F14043L460 46

F14043L470 47

F14043L480 48

F14043L490 49

F14043L500 50

F14043L510 51

PARTOUTSIDE LENGTH

(IN)

F14043L520 52

F14043L530 53

F14043L540 54

F14043L550 55

F14043L560 56

F14043L570 57

F14043L580 58

F14043L590 59

F14043L600 60

F14043L610 61

F14043L620 62

F14043L630 63

PARTOUTSIDE LENGTH

(IN)

F14044L800 80

F14044L810 81

F14044L820 82

F14044L830 83

F14044L840 84

F14044L850 85

F14044L860 86

F14044L870 87

F14044L880 88

F14044L890 89

F14044L900 90

F14044L910 91

F14044L920 92

F14044L930 93

F14044L940 94

F14044L950 95

F14044L960 96

F14044L970 97

F14044L980 98

F14044L990 99

F14044L1000 100

FRACTIONAL HP V-BELTS

Page 26: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

24 | Aftermarket Motor & Accessories Guide

PARTOUTSIDE

LENGTH (IN)

F14045L230 23

F14045L240 24

F14045L250 25

F14045L260 26

F14045L270 27

F14045L280 28

F14045L290 29

F14045L300 30

F14045L310 31

F14045L320 32

F14045L330 33

F14045L340 34

F14045L350 35

F14045L360 36

F14045L370 37

F14045L380 38

F14045L390 39

F14045L400 40

F14045L410 41

F14045L420 42

F14045L430 43

F14045L440 44

F14045L450 45

F14045L460 46

F14045L470 47

F14045L480 48

PARTOUTSIDE

LENGTH (IN)

F14045L490 49

F14045L500 50

F14045L510 51

F14045L520 52

F14045L530 53

F14045L540 54

F14045L550 55

F14045L620 62

F14045L630 63

F14045L640 64

F14045L650 65

F14045L660 66

F14045L670 67

F14045L680 68

F14045L690 69

F14045L700 70

F14045L710 71

F14045L720 72

F14045L730 73

F14045L740 74

F14045L750 75

F14045L760 76

F14045L770 77

F14045L780 78

F14045L790 79

F14045L800 80

5L SIZES

PARTOUTSIDE

LENGTH (IN)

F14045L830 83

F14045L840 84

F14045L850 85

F14045L860 86

F14045L870 87

F14045L880 88

F14045L890 89

F14045L560 56

F14045L570 57

F14045L580 58

F14045L590 59

F14045L910 91

F14045L920 92

F14045L930 93

F14045L940 94

F14045L950 95

F14045L600 60

F14045L610 61

F14045L960 96

F14045L970 97

F14045L980 98

F14045L990 99

F14045L1000 100

F14045L810 81

F14045L820 82

FAST FAN BELTS

FRACTIONAL HP V-BELTS

FR

AC

TIO

NA

L H

P V

-BE

LTS

Page 27: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 25

FAST FAN BELTS

MU

LTIP

LE

V-B

ELT

S

For multiple drive, high speed and high torque operation on light or heavy industrial or automotive machinery, FAST® Multiple V-Belts boast exceptional length, stability, and drive uniformity. Rigorous testing has shown these premium quality belts to have twice the service life or significantly greater transmission capacity than other multiple V-Belts.

PARTOUTSIDE

LENGTH (IN)

F1402A20 22

F1402A21 23

F1402A22 24

F1402A23 25

F1402A24 26

F1402A25 27

F1402A26 28

F1402A27 29

F1402A28 30

F1402A29 31

F1402A30 32

F1402A31 33

F1402A32 34

F1402A33 35

F1402A34 36

F1402A35 37

F1402A36 38

F1402A37 39

F1402A38 40

F1402A39 41

F1402A40 42

F1402A41 43

F1402A42 44

F1402A43 45

F1402A44 46

F1402A45 47

F1402A46 48

F1402A47 49

F1402A48 50

F1402A49 51

PARTOUTSIDE

LENGTH (IN)

F1402A50 52

F1402A51 53

F1402A52 54

F1402A53 55

F1402A54 56

F1402A55 57

F1402A56 58

F1402A57 59

F1402A58 60

F1402A59 61

F1402A60 62

F1402A61 63

F1402A62 64

F1402A63 65

F1402A64 66

F1402A65 67

F1402A66 68

F1402A67 69

F1402A68 70

F1402A69 71

F1402A70 72

F1402A71 73

F1402A72 74

F1402A73 75

F1402A74 76

F1402A75 77

F1402A76 78

F1402A77 79

F1402A78 80

F1402A79 81

A SIZES

PARTOUTSIDE

LENGTH (IN)

F1402A80 82

F1402A81 83

F1402A82 84

F1402A83 85

F1402A84 86

F1402A85 87

F1402A86 88

F1402A87 89

F1402A88 90

F1402A89 91

F1402A90 92

F1402A91 93

F1402A92 94

F1402A93 95

F1402A94 96

F1402A95 97

F1402A96 98

F1402A97 99

F1402A98 100

F1402A105 107

F1402A110 112

F1402A112 114

F1402A120 122

F1402A128 130

F1402A136 138

F1402A144 146

F1402A158 160

F1402A173 175

F1402A180 182

MULTIPLE V-BELTS

Page 28: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

26 | Aftermarket Motor & Accessories Guide

PARTOUTSIDE

LENGTH (IN)

F1402B25 28

F1402B26 29

F1402B27 30

F1402B28 31

F1402B29 32

F1402B30 33

F1402B31 34

F1402B32 35

F1402B33 36

F1402B34 37

F1402B35 38

F1402B36 39

F1402B37 40

F1402B38 41

F1402B39 42

F1402B40 43

F1402B41 44

F1402B42 45

F1402B43 46

F1402B44 47

F1402B45 48

F1402B46 49

F1402B47 50

F1402B48 51

F1402B49 52

PARTOUTSIDE

LENGTH (IN)

F1402B50 53

F1402B51 54

F1402B52 55

F1402B53 56

F1402B54 57

F1402B55 58

F1402B56 59

F1402B57 60

F1402B58 61

F1402B59 62

F1402B60 63

F1402B61 64

F1402B62 65

F1402B63 66

F1402B64 67

F1402B65 68

F1402B66 69

F1402B67 70

F1402B68 71

F1402B69 72

F1402B70 73

F1402B71 74

F1402B72 75

F1402B73 76

F1402B74 77

B SIZES

PARTOUTSIDE

LENGTH (IN)

F1402B75 78

F1402B76 79

F1402B77 80

F1402B78 81

F1402B79 82

F1402B81 84

F1402B82 85

F1402B83 86

F1402B84 87

F1402B85 88

F1402B86 89

F1402B87 90

F1402B88 91

F1402B89 92

F1402B90 93

F1402B91 94

F1402B92 95

F1402B93 96

F1402B94 97

F1402B95 98

F1402B96 99

F1402B97 100

F1402B100 103

F1402B101 104

F1402B103 105

PART OUTSIDE LENGTH (IN)

F1402C51 55

F1402C60 64

F1402C68 72

F1402C75 79

F1402C81 85

F1402C85 89

F1402C90 94

F1402C96 100

F1402C105 109

F1402C109 113

F1402C112 116

F1402C115 119

F1402C120 124

PART OUTSIDE LENGTH (IN)

F1402C128 132

F1402C136 140

F1402C144 148

F1402C150 154

F1402C158 162

F1402C162 166

F1402C173 177

F1402C180 184

F1402C195 199

F1402C210 214

F1402C225 229

F1402C240 244

F1402C255 259

C SIZES

PART OUTSIDE LENGTH (IN)

F1402C270 274

F1402C285 289

F1402C300 304

F1402C315 319

F1402C330 334

F1402C345 349

F1402C360 364

F1402C390 394

F1402C420 424

F1402C450 454

F1402C480 484

PARTOUTSIDE

LENGTH (IN)

F1402B105 108

F1402B108 111

F1402B111 114

F1402B112 115

F1402B120 123

F1402B124 127

F1402B128 131

F1402B133 136

F1402B136 139

F1402B144 147

F1402B158 161

F1402B162 165

F1402B173 176

F1402B180 183

F1402B195 198

F1402B210 213

F1402B225 228

F1402B240 243

F1402B255 258

F1402B270 273

F1402B285 288

F1402B300 303

F1402B315 318

FAST FAN BELTS

MULTIPLE V-BELTS

MU

LTIP

LE

V-B

ELT

S

Page 29: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 27

FAST FAN BELTS

NARROW V-BELTS - COGGED The unique design and superior quality of the FAST® Narrow V-Belt allow you to build or redesign drive systems using smaller pulleys, with shorter center distances (reducing system weight and space) and increased horsepower capacity (exceeding RMA standards by 23.6% average). NOTE: The FAST® Narrow V-Belt in three section sizes is ideal for all applications covered by five section sizes of multiple V-belts. For multiple or single drives, the 3V replaces A, B, and C belts; the 5V replaces C and D belts.

PART OUTSIDE LENGTH (IN)

F14033VX1000 100

F14033VX1060 106

F14033VX1120 112

F14033VX1250 125

F14033VX1320 132

F14033VX1400 140

F14033VX215 21.5

F14033VX250 25

F14033VX265 26.5

F14033VX280 28

F14033VX300 30

F14033VX315 31.5

F14033VX335 33.5

F14033VX355 35.5

F14033VX375 37.5

F14033VX400 40

F14033VX425 42.5

F14033VX450 45

F14033VX475 47.5

F14033VX500 50

F14033VX530 53

F14033VX560 56

F14033VX600 60

F14033VX630 63

F14033VX670 67

F14033VX710 71

F14033VX750 75

F14033VX800 80

F14033VX850 85

F14033VX900 90

F14033VX950 95

3V SIZES

PART OUTSIDE LENGTH (IN)

F14035V2120 212

F14035V2240 224

F14035V2360 236

F14035V2500 250

F14035V2650 265

F14035V2800 280

F14035V3000 300

F14035V3150 315

F14035V3350 335

F14035V3550 355

F14035VX500 50

F14035VX530 53

F14035VX560 56

F14035VX600 60

F14035VX630 63

F14035VX670 67

F14035VX710 71

F14035VX750 75

F14035VX800 80

F14035VX850 85

F14035VX900 90

F14035VX950 95

F14035VX1000 100

F14035VX1120 112

F14035VX1180 118

F14035VX1250 125

F14035VX1320 132

F14035VX1400 140

F14035VX1500 150

F14035VX1600 160

F14035VX1700 170

F14035VX1800 180

F14035VX1900 190

F14035VX2000 200

5V SIZES

NA

RR

OW

V-B

ELT

S -

CO

GG

ED

Page 30: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

28 | Aftermarket Motor & Accessories Guide

BROWNING BELTS

BR

OW

NIN

G B

ELT

S

FHP BELTS

We offer a full line of Browning Products - if you do not see them here, please call us they are available upon request.

FEATURES:• Wrapped construction

provides smooth, quiet operation

• Formulated for maximum flexibility with smaller diameter sheaves

• Oil and heat resistant - static conducting

PARTLENGTH

WT. LBS. OUTSIDE PITCH

3L170 17.0 16.3 .05

3L180 18.0 17.3 .06

3L190 19.0 18.3 .06

3L200 20.0 19.3 .06

3L210 21.0 20.3 .06

3L220 22.0 21.3 0.07

3L230 23.0 22.3 0.07

3L240 24.0 23.3 0.08

3L250 25.0 24.3 0.08

4L170 17.0 16.0 0.10

4L180 18.0 17.0 0.10

4L190 19.0 18.0 0.11

4L200 20.0 19.0 0.11

4L210 21.0 20.0 0.12

4L220 22.0 21.0 0.12

PARTLENGTH

WT. LBS.

OUTSIDE PITCH

A20 22.2 21.3 0.2

A21 23.2 22.3 0.2

A22 24.2 23.3 0.2

A23 25.2 24.3 0.2

A24 26.2 25.3 0.2

A25-C 27.2 26.3 0.2

A26 28.2 27.3 0.2

A27 29.2 28.3 0.2

A28 30.2 29.3 0.2

A29 31.2 30.3 0.2

A30 32.2 31.3 0.2

A31 33.2 32.3 0.21

A32 34.2 33.3 0.2

A33 35.2 34.3 0.2

A34 36.2 35.3 0.2

A35-C 37.2 36.3 0.2

A36 38.2 37.3 0.3

A37 39.2 38.3 0.3

A38 40.2 39.3 0.3

A39 41.2 40.3 0.3

A40 42.2 41.3 0.3

A41 43.2 42.3 0.3

A42-C 44.2 43.3 0.3

A43 45.2 44.3 0.3

A44-C 46.2 45.3 0.3

A45-C 47.2 46.3 0.3

A46 48.2 47.3 0.3

A47 49.2 48.3 0.3

A48 50.2 49.3 0.3

A49-C 51.2 50.3 0.4

A50 52.2 51.3 0.4

A51 53.2 52.3 0.4

A52 54.2 53.3 0.4

A53 55.2 54.3 0.4

A54 56.2 55.3 0.4

A55-C 57.2 56.3 0.4

A56 58.2 57.3 0.4

A57 59.2 58.3 0.4

A58-C 60.2 59.3 0.4

A59 61.2 60.3 0.4

A60 62.2 61.3 0.4

A61 63.2 62.3 0.4

A62 64.2 63.3 0.4

A64 66.2 65.3 0.4

PARTLENGTH

WT. LBS.

OUTSIDE PITCH

A65 67.2 66.3 0.5

A66 68.2 67.3 0.5

A68 70.2 69.3 0.5

B108 111.0 109.8 1.2

B34 37.0 35.8 0.4

B35 38.0 36.8 0.4

B36 39.0 37.8 0.4

B38 41.0 39.8 0.4

B40 43.0 41.8 0.5

B41 44.0 42.9 0.5

B42 45.0 43.8 0.5

B43 46.0 44.8 0.5

B44 47.0 45.8 0.5

B45 48.0 46.8 0.5

B46 49.0 47.8 0.5

B47 50.0 48.8 0.5

B48 51.0 49.8 0.5

B49 52.0 50.8 0.6

B50 53.0 51.8 0.6

B51 54.0 52.8 0.6

B52 55.0 53.8 0.6

B53 56.0 54.6 0.6

B54 57.0 55.8 0.6

B55 58.0 56.8 0.6

B56 59.0 57.8 0.6

B57 60.0 58.8 0.7

B58 61.0 59.8 0.7

B59 62.0 60.8 0.7

B60 63.0 61.8 0.7

B61 64.0 62.8 0.7

B62-C 65.0 63.8 0.7

B63 66.0 64.8 0.7

B64 67.0 65.8 0.7

B65 68.0 66.8 0.7

B66 69.0 67.8 0.7

B67 70.0 68.8 0.7

B68 71.0 69.8 0.7

B70 73.0 71.8 0.8

B71 74.0 72.8 0.8

B72 75.0 73.8 0.8

B75-C 78.0 76.8 0.8

B81 84.0 82.8 0.9

B85 88.0 86.8 0.9

B90 93.0 91.8 1.0

Note: The -C in the part number is a FAST Parts notation only. There is no difference in the belt part that contains a C, versus one that does not.

SUPER GRIPNOTCH® BELTS

FEATURES: • Static conducting

Page 31: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 29

BROWNING BELTS

PARTLENGTH

WT. LBS.

OUTSIDE PITCH

AX20 22.2 21.3 0.2

AX21 23.2 22.3 0.2

AX22 24.2 23.3 0.2

AX23 25.2 24.3 0.2

AX24 26.2 25.3 0.2

AX25 27.2 26.3 0.2

AX26 28.2 27.3 0.2

AX27 29.2 28.3 0.2

AX28 30.2 29.3 0.2

AX29 31.2 30.3 0.2

AX30 32.2 31.3 0.2

AX31 33.2 32.3 0.2

AX32 34.2 33.3 0.2

AX33 35.2 34.3 0.2

AX34-C 36.2 35.3 0.2

AX35 37.2 36.3 0.2

AX36 38.2 37.3 0.3

AX37 39.2 38.3 0.3

AX38 40.2 39.3 0.3

AX39 41.2 40.3 0.3

AX40 42.2 41.3 0.3

AX41 43.2 42.3 0.3

AX42 44.2 43.3 0.3

AX43 45.2 44.3 0.3

AX44 46.2 45.3 0.3

AX45 47.2 46.3 0.3

AX46 48.2 47.3 0.3

AX47 49.2 48.3 0.3

AX48 50.2 49.3 0.3

AX49 51.2 50.3 0.4

AX50 52.2 51.3 0.4

AX51-C 53.2 52.3 0.4

GRIPNOTCH® BELTS

PARTLENGTH

WT. LBS.

OUTSIDE PITCH

AX52 54.2 53.3 0.4

AX53 55.2 54.3 0.4

AX54 56.2 55.3 0.4

AX55 57.2 56.3 0.4

AX56 58.2 57.3 0.4

AX57 59.2 58.3 0.4

AX58 60.2 59.3 0.4

AX60 62.2 61.3 0.4

AX62 64.2 63.3 0.4

AX64 66.2 65.3 0.4

BX28 31.0 29.8 0.4

BX32 35.0 33.8 0.4

BX34 37.0 35.8 0.4

BX35 38.0 36.8 0.4

BX36 39.0 37.8 0.4

BX38-C 41.0 39.8 0.4

BX40 43.0 41.8 0.5

BX41 44.0 42.8 0.5

BX42 45.0 43.8 0.5

BX43 46.0 44.8 0.5

BX44 47.0 45.8 0.5

BX45 48.0 46.8 0.5

BX46 49.0 47.8 0.5

BX47 50.0 48.8 0.5

BX48 51.0 49.8 0.6

BX49 52.0 50.8 0.6

BX50 53.0 51.8 0.6

BX51-C 54.0 52.8 0.6

BX52 55.0 53.8 0.6

BX53 56.0 54.8 0.6

BX54-C 67.0 55.8 0.6

BX55 58.0 56.8 0.6

FEATURES:• Precision molded raw

edge construction

• More horsepower in less space

• Notches are molded extra deep

• Oil and heat resistant

• Static conducting

Note: The -C in the part number is a FAST Parts notation only. There is no different in the belt part that contains a C, versus one that does not.

PARTLENGTH

WT. LBS.

OUTSIDE PITCH

BX56 59.0 57.8 0.6

BX57 60.0 58.8 0.6

BX58 61.0 59.8 0.6

BX59 62.0 60.8 0.7

BX60 63.0 61.8 0.7

BX61 64.0 62.8 0.7

BX62 65.0 63.8 0.7

BX63-C 66.0 64.8 0.7

BX64 67.0 65.8 0.7

BX65-C 68.0 66.8 0.8

BX66 69.0 67.8 0.8

BX67 70.0 68.8 0.8

BX68 71.0 69.8 0.8

BX70-C 73.0 71.8 0.8

BX71 74.0 72.8 0.8

BX73 76.0 74.8 0.8

BX74 77.0 75.8 0.8

BX75 78.0 76.8 0.9

BX77 80.0 78.8 0.9

BX78 81.0 79.8 0.9

BX80 83.0 81.8 0.9

BX81 84.0 82.8 0.9

BX83 86.0 84.8 1.0

BX85 88.0 86.8 1.0

BX88 91 89.8 1.0

BX90 93.0 91.8 1.1

BX93 94.8 93.0 1.2

BX95 98.0 96.8 1.1

BX96 99.0 97.8 1.1

BX97-C 100.0 98.8 1.1

BX103 106.0 104.8 1.2

BX108 111.0 109.8 1.3

BR

OW

NIN

G B

ELT

S

Page 32: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

30 | Aftermarket Motor & Accessories Guide

BROWNING BELTS

PART TYPEOUTSIDE LENGTH

WT. LBS.

3VX250 NOTCHED TYPE 25 0.1

3VX265 NON-NOTCHED TYPE 26.5 0.1

3VX280 NOTCHED TYPE 28 0.1

3VX300 NON-NOTCHED TYPE 30 0.1

3VX315 NOTCHED TYPE 31.5 0.1

3VX335 NOTCHED TYPE 33.5 0.1

3VX355 NOTCHED TYPE 35.5 0.2

3VX375 NOTCHED TYPE 37.5 0.2

3VX400 NOTCHED TYPE 40 0.2

3VX425 NOTCHED TYPE 42.5 0.2

3VX450 NOTCHED TYPE 45 0.2

3VX475 NOTCHED TYPE 47.5 0.2

3VX500 NOTCHED TYPE 50 0.2

3VX530 NOTCHED TYPE 53 0.2

3VX560 NOTCHED TYPE 56 0.2

3VX600 NOTCHED TYPE 60 0.3

3VX630 NOTCHED TYPE 63 0.3

3VX670 NOTCHED TYPE 67 0.3

3VX710 NOTCHED TYPE 71 0.3

3VX750 NOTCHED TYPE 75 0.3

3VX800 NOTCHED TYPE 80 0.4

3VX850 NOTCHED TYPE 85 0.4

3VX900 NOTCHED TYPE 90 0.4

3VX950 NOTCHED TYPE 95 0.4

5VX450 NOTCHED TYPE 45 0.4

5VX470 NOTCHED TYPE 47 0.5

5VX490 NOTCHED TYPE 49 0.5

5VX500 NON-NOTCHED TYPE 50 0.6

5VX510 NOTCHED TYPE 51 0.6

5VX530 NON-NOTCHED TYPE 53 0.6

"358" GRIPBELT® AND GRIPNOTCH® BELTS

PART TYPEOUTSIDE LENGTH

WT. LBS.

5VX540 NOTCHED TYPE 54 0.6

5VX550 NOTCHED TYPE 55 0.6

5VX560 NON-NOTCHED TYPE 56 0.6

5VX570 NOTCHED TYPE 57 0.6

5VX580 NOTCHED TYPE 58 0.6

5VX590 NOTCHED TYPE 59 0.6

5VX600 NON-NOTCHED TYPE 60 0.7

5VX610 NOTCHED TYPE 61 0.7

5VX630 NOTCHED TYPE 63 0.7

5VX650 NOTCHED TYPE 65 0.7

5VX660 NOTCHED TYPE 66 0.8

5VX670 NOTCHED TYPE 67 0.8

5VX680 NOTCHED TYPE 68 0.8

5VX690 NOTCHED TYPE 69 0.8

5VX710 NOTCHED TYPE 71 0.8

5VX730 NOTCHED TYPE 73 0.8

5VX740 NOTCHED TYPE 74 0.8

5VX750 NOTCHED TYPE 75 0.8

5VX780 NOTCHED TYPE 78 0.8

5VX800 NOTCHED TYPE 80 0.9

5VX810 NOTCHED TYPE 81 0.9

5VX830 NOTCHED TYPE 83 0.9

5VX840 NOTCHED TYPE 84 0.9

5VX850 NOTCHED TYPE 85 0.9

5VX860 NOTCHED TYPE 86 0.9

5VX880 NOTCHED TYPE 88 0.9

5VX900 NOTCHED TYPE 90 1.0

5VX930 NOTCHED TYPE 93 1.0

5VX950 NOTCHED TYPE 95 1.0

5VX960 NOTCHED TYPE 96 1.0

FEATURES:• Oil and heat resistant

• More horsepower in less space

• Static conducting

BR

OW

NIN

G B

ELT

S

Page 33: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

BROWNING SHEAVES

www.FASTHVACRparts.com | 31

1VP CAST IRON SHEAVES Single groove variable pitch sheaves for “3L”, “4L”, “5L”, “A”, “B” and “5V” belts

2VP CAST IRON SHEAVES Single groove variable pitch sheaves for “3L”, “4L”, “5L”, “A”, “B” and “5V” belts

PART DIAMETER BORE (IN.) WT. LBS. (LESS BUSH)

1VP 56 X 1 1/8 5.35 1 1/8 3

1VP40X5/8 3.75 5/8 1.7

1VP40X7/8-C 3.75 7/8 1.7

1VP44X 1 1/8 4.15 1 1/8 2

1VP44X5/8 4.15 5/8 2

1VP44X7/8-C 4.15 7/8 2

1VP50X 1 1/8 4.75 1 1/8 2.9

1VP56X5/8 5.35 5/8 3.4

1VP56X7/8-C 5.35 7/8 3.4

1VP60X-1-1/8-C 6 1 1/8 5.5

1VP62X 1 1/8 5.95 1 1/8 5.7

1VP65X 1 1/8 6.5 1 1/8 5.8

PART DIAMETER BORE (IN.) WT. LBS. (LESS BUSH)

2VP42X 1 1/8 3.95 1 1/8 2.6

2VP42X7/8 3.95 7/8 2.6

2VP50X 1 1/8 4.75 1 1/8 5.4

2VP56X 1 1/8 5.35 1 1/8 6.6

2VP60X 1 1/8 6 1 1/8 10.2

2VP60X 1 3/8 6 1 3/8 10.2

2VP62X 1 3/8 5.95 1 3/8 10.5

BROWNING

We offer a full line of Browning Products - if you do not see them here, please call us they are available upon request.

BR

OW

NIN

G S

HE

AV

ES

Page 34: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

32 | Aftermarket Motor & Accessories Guide

BROWNING SHEAVES

CAST IRON VL VARIABLE PITCH SHEAVES“VL" Sheaves refurnished with standard keyseats and hollow head setscrews

PART DIAMETER BORE (IN.) WT. LBS. (LESS BUSH)

1VL25X1/2 2.5 1/2 0.8

1VL25X5/8 2.5 5/8 0.8

1VL30X1/2 2.87 1/2 0.9

1VL30X5/8 2.87 5/8 0.9

1VL34X1/2 3.15 1/2 1.2

1VL34X5/8 3.15 5/8 1.2

1VL40X1/2 3.75 1/2 1.7

1VL40X5/8 3.75 5/8 1.7

1VL40X7/8-C 3.75 7/8 1.7

1VL44X1/2 4.15 1/2 1.9

1VL44X5/8 4.15 5/8 1.9

1VL44X7/8 4.15 7/8 1.9

1VM50X5/8 4.75 5/8 1.9

1VM50X7/8 4.75 7/8 1.9

BR

OW

NIN

G S

HE

AV

ES

Page 35: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

www.FASTHVACRparts.com | 33

OVAL MOTOR RUN CAPACITORS - SINGLE

PARTMAX CAN HEIGHT

(IN)

MAX HEIGHT WITH QC'S

(IN)

MFD - COMP

MFD - FAN

F87071513 3.23 3.74 15 10

F87071543 3.23 3.74 15 4

F87071553 3.23 3.74 15 5

F87072053 3.23 3.74 20 5

F87072513 3.62 4.13 25 10

F87072543 3.23 3.74 25 4

F87072553 3.23 3.74 25 5

F87072573 3.23 3.74 25 7.5

F87073053 3.62 4.13 30 5

F87073073 3.62 4.13 30 7.5

F87073543 3.62 4.13 35 4

F87073553 3.62 4.13 35 5

F87073573 4.21 4.72 35 7.5

F87074053 4.21 4.72 40 5

F87074073 4.21 4.72 40 7.5

F87074513 4.21 4.72 45 10

F87074553 4.61 5.12 45 5

F87074573 4.21 4.72 45 7.5

F87075053 4.61 5.12 50 5

F87075553 5.20 5.71 55 5

F87076053 4.02 4.53 60 5

F87078013 4.61 5.12 80 10

F87078053 4.61 5.12 80 5

F87078073 4.61 5.12 80 7.5

370 VOLT DUAL OVAL

PARTMAX CAN HEIGHT

(IN)

MAX HEIGHT WITH QC'S

(IN)

MFD - COMP

MFD - FAN

F87071554 3.23 3.74 15 5

F87072054 3.62 4.13 20 5

F87072074 3.62 4.13 20 7.5

F87072554 3.62 4.13 25 5

F87072574 4.21 4.72 25 7.5

F87073014 4.61 5.12 30 10

F87073054 4.21 4.72 30 5

F87073074 4.61 5.12 30 7.5

F87073514 4.61 5.12 35 10

F87073554 4.61 5.12 35 5

F87073574 4.61 5.12 35 7.5

F87074014 4.21 4.72 40 10

F87074054 3.94 4.45 40 5

F87074074 5.20 5.71 40 7.5

F87074554 5.00 5.51 45 5

F87074574 4.21 4.72 45 7.5

F87075014 4.21 4.72 50 10

F87075054 5.00 5.51 50 5

F87075074 4.21 4.72 50 7.5

F87075574 4.21 4.72 55 7.5

F87076014 4.61 5.12 60 10

F87078054 4.61 5.12 80 5

440 VOLT DUAL OVAL

AC CAPACITORS

FOR MOTOR RUN APPLICATIONS

Note: Distributors that have historically stocked 440 volt and 370 volt capacitors round and / or oval designs can standardize inventory to use a 440 volt capacitors as replacement for a 370 volt capacitor provided the capacitance in (Mfd.) stays exactly the same.

Warning Note: Under no circumstances are we recommending usage of a 370 volt capacitor to replace a 440 volt capacitor. Also our capacitor straps are designed to secure and ground the capacitor, so we don’t recommend mixing oval or round capacitor designs.

OV

AL

MO

TO

R R

UN

CA

PA

CIT

OR

S -

SIN

GL

E

Page 36: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

34 | Aftermarket Motor & Accessories Guide

OVAL RUN CAPACITORS - SINGLE

370 VOLT SINGLE OVAL 440 VOLT SINGLE OVAL

PARTMAX CAN HEIGHT

(IN)

MAX HEIGHT WITH QC'S

(IN)

MFD - COMP

F87070303 2.24 2.76 3

F87070403 2.24 2.76 4

F87070503 2.24 2.76 5

F87070603 2.24 2.76 6

F87070753 2.24 2.76 7.5

F87071003 3.03 3.54 10

F87071253 3.03 3.54 12.5

F87071503 3.03 3.54 15

F87071753 3.43 3.94 17.5

F87072003 3.43 3.94 20

F87072503 3.03 3.54 25

F87073003 3.03 3.54 30

F87073503 3.03 3.54 35

F87074003 3.43 3.94 40

F87074503 4.02 4.53 45

F87075003 4.02 4.53 50

F87075503 4.41 4.92 55

F87076003 4.41 4.92 60

F87078003 3.94 4.45 80

PARTMAX CAN HEIGHT

(IN)

MAX HEIGHT WITH QC'S

(IN)

MFD - COMP

F87070304 2.24 2.76 3

F87070404 2.24 2.76 4

F87070504 2.24 2.76 5

F87070754 2.24 2.76 7.5

F87071004 3.03 3.54 10

F87071254 3.03 3.54 12.5

F87071504 3.03 3.54 15

F87071754 3.03 3.54 17.5

F87072004 3.03 3.54 20

F87072504 3.03 3.54 25

F87073004 3.43 3.94 30

F87073504 3.94 4.45 35

F87074004 4.41 4.92 40

F87074504 4.41 4.92 45

F87075004 5.00 5.51 50

F87075504 3.62 4.13 55

F87076004 3.94 4.45 60

F87077004 4.41 4.92 70

F87078004 4.41 4.92 80

OV

AL

MO

TO

R R

UN

CA

PA

CIT

OR

S D

UA

L

Page 37: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

OVAL RUN CAPACITORS - DUAL

www.FASTHVACRparts.com | 35

RO

UN

D M

OTO

R R

UN

CA

PA

CIT

OR

S

PART MAX CAN HEIGHT (IN) MAX HEIGHT WITH QC's (IN) MFD - COMP MFD - FAN

F87071554R 2.64 3.15 15 5

F87072054R 3.03 3.54 20 5

F87072554R 3.43 3.94 25 5

F87073054R 4.02 4.53 30 5

F87073554R 4.02 4.53 35 5

F87073574R 4.02 4.53 35 7.5

F87074054R 4.41 4.92 40 5

F87074074R 4.41 4.92 40 7.5

F87074554R 4.02 4.53 45 5

F87074574R 4.02 4.53 45 7.5

F87075054R 4.02 4.53 50 5

F87075514R 4.02 4.53 55 10

F87075554R 4.02 4.53 55 5

F87075574R 4.02 4.53 55 7.5

F87076054R 4.41 4.92 60 5

F87076074R 4.41 4.92 60 7.5

F87077054R 5.00 5.51 70 5

F87077554R 5.00 5.51 75 5

F87078054R 5.00 5.51 80 5

ROUND MOTOR RUN CAPACITOR - DUAL370 VOLT DUAL ROUND

PART MAX CAN HEIGHT (IN) MAX HEIGHT WITH QC's (IN) MFD - COMP MFD - FAN

F87071553R 2.64 3.15 15 5

F87072053R 2.64 3.15 20 5

F87072553R 3.03 3.54 25 5

F87072573R 3.03 3.54 25 7.5

F87073053R 3.03 3.54 30 5

F87073073R 3.62 4.13 30 7.5

F87073553R 3.43 3.94 35 5

F87073573R 4.21 4.72 35 7.5

F87074053R 3.62 4.13 40 5

F87074073R 3.62 4.13 40 7.5

F87074513R 4.02 4.53 45 10

F87074553R 4.02 4.53 45 5

F87074573R 4.02 4.53 45 7.5

F87075053R 5.00 5.51 50 5

F87075073R 4.41 4.92 50 7.5

F87075553R 5.00 5.51 55 5

F87075573R 4.41 4.92 55 7.5

F87076013R 5.00 5.51 60 10

F87076053R 5.00 5.51 60 5

F87076073R 5.00 5.51 60 7.5

F87077013R 4.02 4.53 70 10

F87077053R 4.02 4.53 70 5

F87077073R 4.02 4.53 70 7.5

F87078013R 5.00 5.51 80 10

F87078053R 4.02 4.53 80 5

F87078073R 4.41 4.92 80 7.5

440 VOLT DUAL ROUND

Page 38: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

ROUND MOTOR RUN CAPACITORS

36 | Aftermarket Motor & Accessories Guide

RO

UN

D M

OTO

R R

UN

CA

PA

CIT

OR

S

ROUND MOTOR RUN CAPACITOR - SINGLE370 VOLT SINGLE ROUND

PART MAX CAN HEIGHT (IN)MAX HEIGHT

WITH QC'S (IN)MFD - COMP

F87070503R 2.24 2.76 5

F87071003R 2.24 2.76 10

F87071503R 2.24 2.76 15

F87072503R 2.64 3.15 25

F87073003R 3.03 3.54 30

F87075003R 4.02 4.53 50

440 VOLT SINGLE ROUND

PART MAX CAN HEIGHT (IN)MAX HEIGHT

WITH QC'S (IN)MFD - COMP

F87071504R 2.64 3.15 15

F87072004R 2.64 3.15 20

F87072504R 3.03 3.54 25

F87073004R 3.43 3.94 30

F87073504R 4.02 4.53 35

F87074004R 4.02 4.53 40

F87074504R 4.41 4.92 45

F87075004R 5.00 5.51 50

F87075504R 4.02 4.53 55

F87076004R 4.02 4.53 60

Page 39: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

www.FASTHVACRparts.com | 37

PA

RT

S &

AC

CE

SS

OR

IES

MOTOR MOUNTING

MOTOR MOUNT KITStamped steel motor mounting kits for 42 and 48 frame direct drive blower motors. Kits contain belly band, mounting arms, rubber isolation grommets and 1/4-20 sleeved bolts and nuts for attaching mount to fan housing.

PART MOTOR DIAMETER BOLT CIRCLE

F83010074 5.3" 11.6"

F83010075 5" 11"

ADJUSTABLE MOTOR MOUNT KITUse when replacing motors which originally had welded on mounting ears. Mounting ears have 5/16" slots and 3/4" knockouts which are adaptable to a wide range of mounting dimensions.

PART

F83010015

TORSION FLEX BRACKET

PARTMOTOR FRAME

BOLT CIRCLE

EMERSON® NO.

F83010010 42 9 9/32" 16

F83010011 48 10" 17

TORSION FLEX BRACKETAn economical alternative to conventional mounts that require rubber grommets.

• Fits 9" or 10" blowers

• Maximum motor weight is 16 lbs

• Used with 5 1/2" diameter direct drive blower motors

PART

F83010073

MOTOR DIAGNOSTICS

• 16-Pin and 4-Pin Connector for diagnostics on Genteq Variable Speed Models

• Works with ECM models: 2.0, 2.3, 2.5, 3,0 and Eon

• Comes with ECM Service Guide

PART

GE-A447

TEC INSPECT

BRACKETS

Page 40: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

38 | Aftermarket Motor & Accessories Guide

FLEXIBLE MOUNT "BELLY" BAND ADAPTERAdapts either to a 5" diameter motor (42-frame), or a 5 5/8" (48-frame) to mount on 9" and 10" blowers.

PART FITS

05407401 5" Motor

05407402 5 5/8" Motor

PA

RT

S &

AC

CE

SS

OR

IES

MOTOR MOUNTING BRACKETSupported from the housing venturi, mounting brackets are adjusted for motors 3 1/2" to 6 1/8" in length and accommodates a 48-frame motor. Adjusts to various wheel widths with the necessary hardware furnished.

PARTBLOWER

SIZE

38251401 9"

38251501 10"

02612601 11"

UNIVERSAL MOTOR MOUNTING BRACKETS

Accomodates 10" and 12" blowers (includes mounting hardware).

PART 42-FRAME MOTORS (5" DIA.)

PART 48-FRAME MOTORS (5 5/8" DIA.)

BLOWER SIZE

02869101 02869201 10"

N/A 05409101 12"

BEARING BRACKETS

Note, 18" version has 2 belt holes on each bracket leg. One piece bracket, sold individually.

PART

BELT DRIVE

BLOWER (1)

A B OD*

00896004 18" 9 5/16" 8 13/16" 2 1/2"

01443102 15" 7 13/16" 7 7/16" 2 1/2"

01573001 12" 6 5/16" 6" 2 1/2"

*OD as measured over rubber cushion

KNOCK DOWN BRACKET KIT

For easier installation. Accommodates bearings that have 1 13/16" O.D. (Fits up to 18 1/2" bolt circle.)

PART (PAIR) O.D. OF RUBBER CUSHION

38269901 1 13/16"

FOR BELTED DRIVE BLOWERS

Page 41: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

www.FASTHVACRparts.com | 39

PA

RT

S &

AC

CE

SS

OR

IES

SLEEVE BEARING BRACKET KIT• Ideal for replacing obsolete pillow

blocks and streamlined bearings

• Can also be used in some evaporative cooler applications

• Specially designed to fit most blowers from 9" to 16" sizes

• Sturdy, compact, 10-guage steel bearing and bracket - completely assembled and ready to mount

• Sintered bronze ball assembly securely held in a spherical rubber isolating liner to assure maximum vibration absorption, quiet operation, constant self-alignment and long life

• Packaged in pairs with shaft and hardware group

• 19.25" overall diameter

PARTSHAFT

DIA.MAXIMUM

HPSHAFT

LENGTH

02917501 3/4" 3/4 HP 20"

02917601 1" 1 HP 25"

BEARINGS

LAU-PAK - SLEEVE SEALED TYPE BEARINGS WITH INSULATORSelf-aligning, factory-packed with a supply of plastic petroleum assuring proper lubrication during the long life of the bearing. Self-aligning, porous bronze sleeve pressed in housing.

NOTE: Temperature range for sleeve bearings: 40° - 135°

PART (PAIR) SHAFT DIA. O.D.*

38244301 5/8" 1 13/16"

38244302 3/4" 1 13/16"

38244303 1" 2 1/2"

SEALED SLEEVE BEARINGS (REPLACES BRUNDAGE)

Self-aligning, factory-packed with a supply of plastic petroleum assuring proper lubrication during life of bearing

NOTE: Temperature range for sleeve bearings: 40° - 135°

PART (PAIR) SHAFT DIA. O.D.*

38269401 3/4" 2 1/16"

38269501 1" 2 1/16"

Page 42: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

40 | Aftermarket Motor & Accessories Guide

PA

RT

S &

AC

CE

SS

OR

IES

For use when operating conditions exceed the limits of sleeve bearings or where repetitive failures occur. These bearings are pre-lubricated at the factory and require no further lubrication or attention. They are equipped with seals for positive grease retention and protection against contaminants.

NOTE: Temperature range for sleeve bearings: 40° - 135°

SEALED TYPE BALL BEARINGS WITH INSULATOR

PART (PAIR)

TEMP. RANGE °F

SHAFT DIA. W/

INTERLOCKING THRUST COLLAR

O.D.*

38258801 -20° +180° 3/4" 1 13/16"

38259001 -20° +180° 1" 2 17/32"

38256201 -20° +180° 1 3/16" 2 17/32"

*O.D. as measured over rubber cushion.

Self-aligning, self-oiling, with bronze bushing held in housing under light, uniform, spring presser, providing uniform distribution of lubricant through pores of bushing. Drive type oil cup.

NOTE: Shipped dry. Lubricate at time of installation with SAE 20 or 30 weight oil.

LAU OIL TYPE - SLEEVE BEARINGS WITH INSULATOR

PART (PAIR)* SHAFT DIA. O.D. *

38240401 5/8" 1 13/16"

38244201 3/4" 1 13/16"

38244202 1" 2 1/2"

*O.D. as measured over rubber cushion.

Self-oiling with sintered bronze bushings and drive type oil cups.

OIL SLEEVE BEARINGS(REPLACES BRUNDAGE)

PART (PAIR)* SHAFT DIA. O.D.*

38269601 3/4" 2 1/16"

38269701 1" 2 1/16"

*O.D. as measured over rubber cushion.

Page 43: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

www.FASTHVACRparts.com | 41

PA

RT

S &

AC

CE

SS

OR

IES

Self-aligning, self-oiling with sintered bronze bushings and drive type oil cups.

NOTE: Re-lubricate with SAE 20 or 30 weight oil. (Due to wicking, may need to oil at time of installation.)

OIL TYPE - SLEEVE BEARINGS WITH INSULATOR

PART (PAIR)* SHAFT DIA. O.D. *

38245001 3/4" 1 27/32"

38244901 1" 1 27/32"

38209401 1" Heavy Duty 2 1/2"

*O.D. as measured over rubber cushion.

This cartridge type bearing has been designed to give you fast, easy, interchangeability. It will fit any "spider type" bracket used on 9", 10" and 12" blowers.

Sintered bronze bushing pressed into steel bearing caps and cushioned in heavy neoprene conducive rubber. Factory-packed with lubricant for many years of quiet, trouble-free service. The cartridge bearing with a journal may permit use of old shaft.

CARTRIDGE TYPE SLEEVE BEARINGS

PART (PAIR)* SHAFT DIA. O.D. *

38209101 3/4" w/thrust & spacer 1 13/16"

38227201 3/4" w/journal 1 13/16"

38209001 1" 1 13/16"

*O.D. as measured over rubber cushion.

• Light duty series• Molded rubber outer liner• Eccentric self-locking collar• Permanently lubricated• Quiet operation• Width: 1"

FAST® BALL BEARING CARTRIDGE UNITS

PARTOUTSIDE

DIA.BORE DIA.

F83012202 2.5" 1/2"

F83012502 2.5" 5/8"

F83012302 1.8" 3/4"

F83012304 2.5" 3/4"

F83012201 1.7" 1/2"

F83012102 2.5" 1"

F83012103 2.5" 1"

F83012901 2.5" 1 3/16"

• Porous bronze sleeve• Sealed type• Self-aligning

FAST® BALL BEARING CARTRIDGE UNITS

PARTOUTSIDE

DIA.BORE DIA.

WIDTH

F83012303 1 13/16" 3/4" 1"

F83012101 2 1/2" 1" 1 3/8"

Page 44: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

42 | Aftermarket Motor & Accessories Guide

PA

RT

S &

AC

CE

SS

OR

IES

PART (PAIR) SHAFT DIA.

38220401 5/8"

38208601 3/4"

38208701 1"

38209301* 1" Heavy Duty

Heavy neoprene cushioned, re-oilable porous bronze bushing in a pressed steel ball unit held firmly in a housing of two-piece interlocking steel.

This high quality self-aligning static-free, pillow block will assure quiet operation and many years of trouble-free performance. Two 1/8" rubber spacers provided for use, if needed.

PILLOW BLOCK SLEEVE BEARINGS

* Dimensions for the heavy duty pillow block are: mounting holes on center 3 1/2", base to shaft center 1 3/16", width 1 1/2"

• Durable cast- iron construction

• Pre-lubricated bearings

• Re-greasable

NOTE: Temperature Range: -30 to 200°F

PILLOW BLOCK BALL BEARINGS

PART (PAIR)

SHAFT DIA.

SPREAD MIN.

MAXHOLE SIZE

O.D.*

38256701 3/4" 3 5/8" 3 7/8"9/16" x 13/32"

3 5/16"

38256801 1" 3 7/8" 4 1/8"9/16" x 13/32"

1 7/16"

38256901 1 3/16" 4 1/2" 4 3/4"3/4" x 9/16"

1 11/16"

38257001 1 7/16" 4 3/5" 5"3/4" x 9/16"

1 7/8"

• Permanently lubricated• Rubber cushion interliner• Eccentric locking collar• Two-piece pressed steel housing• Self-aligning

FAST® PILLOW BLOCK LIGHT DUTY SERIES

PART

BASE TO

SHAFT CENTER

MOUNTING CENTER

DISTANCE

BORE DIA.

TYPE

F83012203 9/16" 2" 1/2" SLV

F83012503 .70" 3" 5/8" SLV

F83012501 1" 3" 5/8" BALL

F83012306 1 1/8" 3 3/8" 3/4" BALL

F83012104 1 5/16" 3 3/4" 1" BALL

F83012904 1 5/16" 3 3/4" 1 3/16" BALL

Page 45: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PARTS & ACCESSORIES

www.FASTHVACRparts.com | 43

PA

RT

S &

AC

CE

SS

OR

IES

• Developed to eliminate end-play on sleeve bearing blowers. Replaces old style spring design. Plastic sleeve with assortment of spacers make adjustment easy on any size blower.

• Easy-to-follow instructions included. Available in 3/4" shaft size only.

THRUST SLEEVE & SPACER KIT

PART (PAIR)* SHAFT DIA.

38220301 3/4"

• Sheet metal thrust collar in 3/4", 5/8" and 1" size. All with hollow head (Allen) setscrews.

• Kit consists of one pair packaged with thrust washers. Order by part number.

THRUST COLLAR KIT

PART (PAIR)*

SHAFT DIA.

38243101 5/8"

38220601 3/4"

38220701 1"

Packaged 12 per bag.

THRUST SPACER KIT

PART (PAIR)* SHAFT DIA.

38249101 5/8"

38249102 3/4"

38249103 1"

Motor attachment and adjustment hardware for 9", 10", 12" and 15" blowers.

MOTOR MOUNTING HARDWARE KIT

PART

38252101

• Porous bronze sleeve• Self-aligning• Spherical bearing cartridge• Quiet operation• Oil cup for re-lubrication

FAST® PILLOW BLOCKBRONZE BEARING

PARTBASE TO SHAFT

CENTER

MOUNTING CENTER

DISTANCE

BORE DIA.

F83012504 1" 3 1/8" 5/8"

F83012305 1" 3 1/8" 3/4"

F83012106 1" 4 1/16" 1"

F83012107 1 3/8" 3 5/16" 1"

Page 46: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PA

RT

S &

AC

CE

SS

OR

IES

PARTS & ACCESSORIES

44 | Aftermarket Motor & Accessories Guide

Tailpiece assembly for proper belt tension adjustment.

MOTOR ADJUSTMENT KIT

PART NO.

38252301

Resilient rubber tips for use with tailpiece assembly to reduce motor vibration and noise.

MOTOR ADJUSTMENT GROMMETS

PART (PACK OF 6)

38252501

Resilient rubber pads snap easily into place. Reduces vibration, wear and noise on blowers, fans, motors, etc. (packaged 12 per bag)

VIBRO-PADS 5/16" HOLE

PART (DOZ)

38220901

• Solid cold-rolled steel• Ground and polished shaft• Universal sizes• Can be cut to proper length

NOTE: When replacing bearings,be sure to replace the shaft.

FAST® BLOWER SHAFTS

PART DIAMETER LENGTH SHAFT

F83014520 5/8" 20" Solid

F83014320 3/4" 20" Solid

F83014335 3/4" 35" Solid

F83014125 1" 25" Solid

F83014135 1" 35" Solid

FAST® STEEL SHAFT BUSHINGS

PARTINSIDE

DIA.OUTSIDE

DIA.LENGTH

F83010062 5/16" 3/8" 1 1/64"

F83010063 5/16" 1/2" 1 1/8"

F83010064 3/8" 1/2" 1 1/8"

F83010076 1/2" 5/8" 1 1/8"

F83010065 1/2" 3/4" 1 1/4"

F83010066 5/8" 3/4" 1 1/4"

F83010067 5/8" 1" 1 1/4"

F83010068 3/4" 1" 1 1/4"

F83010069 1" 1 3/16" 1 1/4"

Page 47: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

PA

RT

S &

AC

CE

SS

OR

IES

PARTS & ACCESSORIES

www.FASTHVACRparts.com | 45

PARTPULLEY

SIZESHAFT

SIZEPITCH DIA.

F13013201 3" 1/2" 1.9 - 2.9"

F13013503 3" 5/8" 1.9 - 2.9"

F13013301 3" 3/4" 1.9 - 2.9"

F13013202 4" 1/2" 2.4 - 3.4"

F13013505 4" 5/8" 2.4 - 3.4"

F13013302 4" 3/4" 2.4 - 3.4"

F13013710 4" 7/8" 2.4 - 3.4"

F13013203 4 1/4" 1/2" 2.8 - 3.8"

F13013507 4 1/4" 5/8" 2.8 - 3.8"

F13013303 4 1/4" 3/4" 2.8 - 3.8"

F13013708 4 1/4" 7/8" 2.8 - 3.8"

F13013204 5" 1/2" 3.4 - 4.4"

F13013504 5" 5/8" 3.4 - 4.4"

F13013304 5" 3/4" 3.4 - 4.4"

F13013706 5" 7/8" 3.4 - 4.4"

• Quality cast iron key way• Designed for long belt life• Corrosion resistant

FAST® ADJUSTABLE MOTOR PULLEYS

PART DIAMETER LENGTH SHAFT

38220501 5/8" 20" Solid

38209601 3/4" 20" Solid

38269301 3/4" 35" Solid

38209501 1" 25" Solid

38249201 1" 35" Solid

When a bearing fails, the shaft is inevitably scored. If not replaced, it will destroy the new bearings. Premium shafting is ground and polished 1018 cold-rolled steel. Excess shaft may be cut off. (Keyways and/or flats are to be added as required in the field.)

NOTE: When replacing bearings, be sure to replace the shaft.

SHAFTS

Page 48: SOLVING CHALLENGING HVAC/R PROBLEMS IS …icpindexing.toddsit.com/userfiles//FAST Motors Catalog...Single Phase For use in light-duty appliances because of low efficiency, power factor

NEW! FREE!FAST® MOBILE TECH APPTHE PARTS STORE THAT’S ALWAYS HANDY.

Download it now at

www.FASTHVACRparts.com

SOLVING CHALLENGING HVAC/R PROBLEMS IS YOUR JOB.

HELPING YOU GET THE PARTS, SUPPLIES AND EQUIPMENT YOU NEED IS OURS.

For the FAST® Parts location nearest you visit www.FASTHVACRparts.com

ICP Part No. 81015600001 Printed 4/17