Solar PV Panels

83

Pu

lsa

PV

Joule Pulsa PV 260Whigh performance ac solar module

AC Advantage

AC system solution

conditions

entire system

Safety

-

Intelligent

-

sis and resolution

management

analytics and automated alerts

safer more secure connection to the module

260W Microinverter

The integrated PV Microinverter, instantly converts

DC to ready to use AC power.

Dimensions (mm)

L W H

1640 992 75

Specifications

Solar cells

6 x 10 pieces in series

Collector height 75mm / 2.95 inch

Collector width 992mm / 39.06 inch

Collector lenght 1640mm / 64.57 inch

Weight (kg) 21.6kg / 47.6lbs

Front glass 3.2mm toughened glass

Frame Anodized aluminium alloy

Cable 0.90m wire (Ø4mm2)

Diodes 6 pieces Schottky by-pass diodes

Junction Box IP65 rated

Output Data (AC) @208 VAC @240 VAC

Maximum Output Power 215W 215W

Nominal output current 1.0A

(arms at nominal

duration)

0.9A

(arms at nominal

duration)

Nominal voltage/range 208V / 183-229V 240V/211-264V

Extended voltage/range 208V/179-232V 240V/206-269V

60.0/59.3-60.5Hz 60.0/59.3-60.5Hz

60.0/59.2-60.6Hz 60.0/59.2-60.6Hz

Power Factor >0.95 >0.95

Maximum units per 20A branch circuit 25 (3 phase) 17 (single phase)

Maximum output fault current 1.05 Arms, over 3 cycles; 25.2 Apeak,

1.74ms duration

Ambient temperature range -40°C to +65°C

NOCT (Nominal Operation Cell Temperature) 45°C ± 2°C

-0.31%/K

+0.07%/K

-0.40%/K

Intensity (W/m2) Impp Vmpp

1000 1 1

800 0.8 0.996

600 0.6 0.99

400 0.4 0.983

200 0.2 0.952

100 0.1 0.921

Note

subjected to change without notice. Additional information can be found on www.

phonosolar.com

measuring system to another.

2. Measurement conditions under irradiance level of Standard Test Conditions

(STC): 1000W/m2, Air mass 1.5 Spectrum, cell temperature of 25°C.

Absolute maximum rating

Intensity (W/m2) Impp

Operating Temperature From -40 to +85°C

Hail Diameter @ 80km/h Up to 25mm

Surface Maximum Load Capacity Up to 5400Pa

Maximum Series Fuse Rating 15A

IEC Application Class (IEC 61215) A

Fire Rating (UL 1703) C

1360

H

860

2-Ø48-9x14 9110

942942

Back s

heet

(bla

ck)

Frame (black)

992

1640

Joule Pulsa PV 260W

85

Pu

lsa

PV

260W Microinverter

The integrated PV Microinverter, instantly converts

DC to ready to use AC power.

The microinverter delivers increased energy harvest

and reduces design and installation complexity

with its all-AC approach. With the M250, the DC

circuit is isolated and insulated from ground, so no

enhances safety, and saves on labor and materials

costs.

Productive

Simple

Specifications

Input Data (DC)

Recommended input power (STC) 210 - 300W

Maximum input DC voltage 48V

Peak power tracking voltage 27V - 39V

Operating range 16V - 48V

Min/Max start voltage 22V / 48V

Max DC short circuit current 15A

Max input current 9.8A

Output Data (AC)

Output Data (AC) @208 VAC @240 VAC

Peak output power 250 W 250 W

Rated (continuous) output

power

240 W 240 W

Nominal output current 1.15 A (A rms

at nominal

duration)

1.0 A (A rms

at nominal

duration)

Nominal voltage/range 208 V / 183-

229 V

240 V / 211-

264 V

60.0 / 57-61

Hz

60.0 / 57-61

Hz

57-62.5 Hz 57-62.5 Hz

Power factor >0.95 >0.95

Maximum units per 20 A

branch circuit

24 (three

phase)

16 (single

phase)

Maximum output fault cur-

rent

850 mA rms

for 6 cycles

850 mA rms

for 6 cycles

96.5%

96.0%

96.5%

reference EN50530)

99.4%

Night time power consumption 65 mW max

Ambient temperature range -40°C to +65°C

Operating temperature range

(internal)

-40°C to +85°C

Dimensions (WxHxD) 171 mm x 173 mm

x 30 mm (without

mounting bracket)

Weight 2.0 kg

Cooling Natural convection -

No fans

Enclosure environmental rating Outdoor - NEMA 6

Features

Compatibility Compatible with 60-

cell PV modules.

Communication Power line

Integrated ground The DC circuit meets

ungrounded PV arrays

-

ment ground is pro-

vided in the Engage

Cable. No additional

GEC or ground is

Monitoring Free lifetime moni-

toring via Enlighten

software

Compliance UL1741/IEEE1547,

FCC Part 15 Class B,

CAN/CSA-C22.2 NO.

0-M91, 0.4-04, and

107.1-01

JOULE IRELAND T +353 1 6237080 F +353 1 626 9337 E [email protected] W www.joule.ie 87