solar pv panels - complete system solutions for home · pdf filejoule pulsa pv 260w high...
TRANSCRIPT
Joule Pulsa PV 260Whigh performance ac solar module
AC Advantage
AC system solution
conditions
entire system
Safety
-
Intelligent
-
sis and resolution
management
analytics and automated alerts
safer more secure connection to the module
260W Microinverter
The integrated PV Microinverter, instantly converts
DC to ready to use AC power.
Dimensions (mm)
L W H
1640 992 75
Specifications
Solar cells
6 x 10 pieces in series
Collector height 75mm / 2.95 inch
Collector width 992mm / 39.06 inch
Collector lenght 1640mm / 64.57 inch
Weight (kg) 21.6kg / 47.6lbs
Front glass 3.2mm toughened glass
Frame Anodized aluminium alloy
Cable 0.90m wire (Ø4mm2)
Diodes 6 pieces Schottky by-pass diodes
Junction Box IP65 rated
Output Data (AC) @208 VAC @240 VAC
Maximum Output Power 215W 215W
Nominal output current 1.0A
(arms at nominal
duration)
0.9A
(arms at nominal
duration)
Nominal voltage/range 208V / 183-229V 240V/211-264V
Extended voltage/range 208V/179-232V 240V/206-269V
60.0/59.3-60.5Hz 60.0/59.3-60.5Hz
60.0/59.2-60.6Hz 60.0/59.2-60.6Hz
Power Factor >0.95 >0.95
Maximum units per 20A branch circuit 25 (3 phase) 17 (single phase)
Maximum output fault current 1.05 Arms, over 3 cycles; 25.2 Apeak,
1.74ms duration
Ambient temperature range -40°C to +65°C
NOCT (Nominal Operation Cell Temperature) 45°C ± 2°C
-0.31%/K
+0.07%/K
-0.40%/K
Intensity (W/m2) Impp Vmpp
1000 1 1
800 0.8 0.996
600 0.6 0.99
400 0.4 0.983
200 0.2 0.952
100 0.1 0.921
Note
subjected to change without notice. Additional information can be found on www.
phonosolar.com
measuring system to another.
2. Measurement conditions under irradiance level of Standard Test Conditions
(STC): 1000W/m2, Air mass 1.5 Spectrum, cell temperature of 25°C.
Absolute maximum rating
Intensity (W/m2) Impp
Operating Temperature From -40 to +85°C
Hail Diameter @ 80km/h Up to 25mm
Surface Maximum Load Capacity Up to 5400Pa
Maximum Series Fuse Rating 15A
IEC Application Class (IEC 61215) A
Fire Rating (UL 1703) C
1360
H
860
2-Ø48-9x14 9110
942942
Back s
heet
(bla
ck)
Frame (black)
992
1640
Joule Pulsa PV 260W
85
Pu
lsa
PV
260W Microinverter
The integrated PV Microinverter, instantly converts
DC to ready to use AC power.
The microinverter delivers increased energy harvest
and reduces design and installation complexity
with its all-AC approach. With the M250, the DC
circuit is isolated and insulated from ground, so no
enhances safety, and saves on labor and materials
costs.
Productive
Simple
Specifications
Input Data (DC)
Recommended input power (STC) 210 - 300W
Maximum input DC voltage 48V
Peak power tracking voltage 27V - 39V
Operating range 16V - 48V
Min/Max start voltage 22V / 48V
Max DC short circuit current 15A
Max input current 9.8A
Output Data (AC)
Output Data (AC) @208 VAC @240 VAC
Peak output power 250 W 250 W
Rated (continuous) output
power
240 W 240 W
Nominal output current 1.15 A (A rms
at nominal
duration)
1.0 A (A rms
at nominal
duration)
Nominal voltage/range 208 V / 183-
229 V
240 V / 211-
264 V
60.0 / 57-61
Hz
60.0 / 57-61
Hz
57-62.5 Hz 57-62.5 Hz
Power factor >0.95 >0.95
Maximum units per 20 A
branch circuit
24 (three
phase)
16 (single
phase)
Maximum output fault cur-
rent
850 mA rms
for 6 cycles
850 mA rms
for 6 cycles
96.5%
96.0%
96.5%
reference EN50530)
99.4%
Night time power consumption 65 mW max
Ambient temperature range -40°C to +65°C
Operating temperature range
(internal)
-40°C to +85°C
Dimensions (WxHxD) 171 mm x 173 mm
x 30 mm (without
mounting bracket)
Weight 2.0 kg
Cooling Natural convection -
No fans
Enclosure environmental rating Outdoor - NEMA 6
Features
Compatibility Compatible with 60-
cell PV modules.
Communication Power line
Integrated ground The DC circuit meets
ungrounded PV arrays
-
ment ground is pro-
vided in the Engage
Cable. No additional
GEC or ground is
Monitoring Free lifetime moni-
toring via Enlighten
software
Compliance UL1741/IEEE1547,
FCC Part 15 Class B,
CAN/CSA-C22.2 NO.
0-M91, 0.4-04, and
107.1-01
JOULE IRELAND T +353 1 6237080 F +353 1 626 9337 E [email protected] W www.joule.ie 87
Pu
lsa
PV