smoke test at bmta
TRANSCRIPT
-
7/23/2019 Smoke Test at BMTA
1/27
SMOKE TEST REPORT
ECOBURN THAILAND Co., Ltd.
99/102, Moo 20, Soi Boommeesap, Bangplee-Tamru RoaTambon Bangpleeyai, Amphur Bangplee, Samutprakarn 1054
T. 02-382-5302 F. 02-382-530
2014
-
7/23/2019 Smoke Test at BMTA
2/27
INDEX1. DIESEL OPACITY SMOKE TEST INTRODUCTION
1) WHAT IS THE DIESEL OPACITY SMOKE TEST (SNAP ACCELERATION TEST)?
2) MEASURING EQUIPMENT
3) HOW TO MEASURE?
4) TEST
5) TEST GALLERY
2. SMOKE TEST
NON-ADDITIVE ECOBURN, ADDITIVE ECOBURN
3. SMOKE TEST RESULT
ECOBURN THAILAND Co., Ltd.
-
7/23/2019 Smoke Test at BMTA
3/27
1. DIESEL OPACITY SMOKE TEST INTRODUCTION
1) WHAT IS THE DIESEL OPACITY SMOKE TEST (SNAP ACCELERATION TEST) ?
DIESEL OPACITY SMOKE TEST IS WORLDS STANDARD SMOKE TEST FOR DIESEL. THE
MEASUREMENT METHOD IS TO SET THE VEHICLE IN IDLE, PUT THE ENGINE TO FULL
ACCELERATION AND MEASURE THE DENSITY OF SOOT/EXHAUST FUMES THAT DISCHARGE
THROUGH VEHICLE EXHAUST GAS ANALYZER, WHICH MEASURES THE DENSITY OF EXHAUST
GAS BY A LIGHT TRANSMISSION. THE STANDARD OF DIESEL OPACITY TEST (SNAP
ACCELERATION TEST) IS 45% IN THAILAND, 2008. (MINISTRY OF NATURAL RESOURCES AND
ENVIRONMENT, THAILAND)
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
4/27
2) MEASURING EQUIPMENT.
DIESEL OPACITY SMOKE METER
(OPA - 101) MADE IN S.KOREA
USED WORLDWIDE
HTTP://WWW.QROTECH.COM
REGISTERED ISO 9001:2000
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
5/27
3) HOW TO MEASURE?
WARMING UP 30 MINUTES THE VEHICLE BEFORE THE TEST. *APPLIES EQUALLY, BEFORE NON ECOBURN
ADDITIVE TREATED AND AFTER ECOBURN ECOBURN ADDITIVE TREATED.
WHEN THE VEHICLE HAS BEEN WARMED UP, TURN OFF EVERYTHING THAT MAY AFFECT THE
MEASUREMENT SUCH AS AIR-CONDITIONING.
INSERT THE SMOKE METER SAMPLING TUBE INTO THE EXHAUST PIPE. STEP ON THE ACCELERATOR
PEDAL AND LISTEN FOR ANY UNUSUAL NOISES.
FUME OUT EXHAUST GAS BY STEPPING ON THE PEDAL TO FULL ACCELERATION AND KEEP THE ENGINE
AT TOP SPEED (HIGHEST POINT OF RPM) FOR TWO SECONDS WITHIN 4 SECONDS, THEN RETURN AND
STAND BY AT STOP OPERATION STATUS FOR 5~6 SECONDS.
REPEAT STEPS AT LEAST THREE TIMES.
AFTER FUMING UP EXHAUST GAS MORE THAN THREE TIMES, CONNECTED TO A POWER SOURCE AND
TURN ON THE SWITCH ON THE SIDE. WARM-UP NEEDS ABOUT 5~6 MINUTES WITH SOUNDING A BEEP.
WHEN DISPLAYED ON 0.0, READY FOR MEASUREMENT.
INSERT THE SAMPLING TUBE INTO THE VEHICLE EXHAUST PIPE.
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
6/27
PRESS THE HOLD BUTTON ONCE.
FUME OUT EXHAUST GAS BY STEPPING ON THE PEDAL TO FULL ACCELERATION TO THE HIGHEST
RPM WITHIN 4 SECONDS, RELEASE THE PEDAL WHEN YOU REACH THE MAXIMUM RPM. (NO NEED
TO KEEP TWO SECONDS WHEN MAXIMUM RPM, TAKE FOOT OFF WHEN MAXIMUM RPM)
DISPLAY SHOWS THE MEASURED VALUE AUTOMATICALLY AND DATA IS OUTPUT BY PRESSING
THE PRINT BUTTON ONCE. FOR RE-MEASUREMENT, PRESS THE HOLD BUTTON TWICE.
IF THREE CONSECUTIVE NUMERICAL DEVIATION VALUES ARE BELOW 5%, THE VALUES COULD
BE CALCULATED AS A AVERAGE VALUE. IF CANNOT GET THE VALUES AS MENTIONED, THE 8TH,
9TH, 10TH VALUES MUST BE CALCULATED AS A AVERAGE VALUE.
TO STOP THE MEASUREMENT, PRESS THE HOLD BUTTON ONCE.
WHEN THE MEASUREMENT IS FINISHED, TURN OFF THE SWITCH.
*WHEN REMOVE THE SAMPLING TUBE FROM THE EXHAUST PIPE, MUST BE
CAUTIOUS HOT TEMPERATURE.
*THE MEASUREMENT METHOD OF DIESEL OPACITY SMOKE TEST ABOVE ISDEFINED AS THE REGULATION ENFORCEMENT REGARDING TO CAREFUL
INSPECTION IN USE VEHICLE EMISSIONNOTIFICATION NO. 2010-46 OF THE
MINISTRY OF ENVIRONMENT, SOUTH KOREA, 23 APRIL 2010.
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
7/27
4) TEST
TEST PERIOD : 2014. 04. 01 2014. 04. 20
BMTA
ENGINEER MR. NICOM
MR. LOR
MR. WITTAYA PHUSUDMR. PRAYON PUNGMEE
ECOBURN
CTO MR. LEE (ECOBURN INTERNATIONAL)
CEO MR. ANDREW JOE
CTO MR. HENRY BAE
MANAGER MS. PHUNG
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
8/27
5) GALLERY
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
9/27ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
10/27ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
11/27
2. SMOKE TEST
BMTA SELECTED 5 BUSES
5
40107
5 40113
5 40115
5 40300
5 40312
ECOBURN THAILAND CO., Ltd.
-
7/23/2019 Smoke Test at BMTA
12/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40107
-
7/23/2019 Smoke Test at BMTA
13/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40107
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 4. 7 4. 8 4. 9 4. 10 4. 11 4. 12 4. 13 4. 14 4. 15 4. 16 4. 17 4. 18 4. 19 4. 20
Non-Additive Ecoburn Additiv Ecoburn
-
7/23/2019 Smoke Test at BMTA
14/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40107
DATE
OPACITY PEAK VALUE AVERAGE (%)
REMARK
4. 1 61.9%
Non-additive
Ecoburn
4. 2 93.7%
4. 3 94.7%
4. 4 99.6%
4. 5 99.2%
Average (%)
89.8%
4. 6
Non-Smoke Test
Additive
Ecoburn
4. 7
4. 8
4. 9
4. 10
4. 11 80.8%
4. 12 53.3%
4. 13 74.4%
4. 14 61.4%
4. 15 30.2%
4. 16 Air intake Troble
4. 17
50.2%
4. 18 37.2%
4. 19 30.5%
4. 20 39.1%
Average (%)
35.6% Last 3 days (4.18, 4.19, 4.20) Average
-
7/23/2019 Smoke Test at BMTA
15/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40113
-
7/23/2019 Smoke Test at BMTA
16/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40113
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 4. 7 4. 8 4. 9 4. 10 4. 11 4. 12 4. 13 4. 14 4. 15 4. 16 4. 17 4. 18 4. 19 4. 20
Non-Additive Ecoburn
Additive Ecoburn
-
7/23/2019 Smoke Test at BMTA
17/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40113
DATE
OPACITY PEAK VALUE AVERAGE (%)
REMARK
4. 1 99.8%
Non-additive Ecoburn
4. 2 87.3%
4. 3 83.8%
4. 4 99.0%
4. 5 98.0%
Average (%)
93.6%
4. 6
Non-Smoke Test
Additive
Ecoburn
4. 7
4. 8
4. 9
4. 10
4. 11 57.3%
4. 12 53.7%
4. 13 45.1%
4. 14 44.2%
4. 15 27.3%
4. 16 38.2%
4. 17
54.4%
4. 18 38.9%
4. 19 33.7%
4. 20 31.1%
Average (%)
34.6% Last 3 days (4.18, 4.19, 4.20) Average
-
7/23/2019 Smoke Test at BMTA
18/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40115
-
7/23/2019 Smoke Test at BMTA
19/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40115
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 4. 7 4. 8 4. 9 4. 10 4. 11 4. 12 4. 13 4. 14 4. 15 4. 16 4. 17 4. 18 4. 19 4. 20
Non-Additive Ecoburn Additive Ecoburn
-
7/23/2019 Smoke Test at BMTA
20/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40115
DATE
OPACITY PEAK VALUE AVERAGE (%)
REMARK
4. 1 100.0%
Non-additive
Ecoburn
4. 2 99.1%
4. 3 99.97%
4. 4 99.97%
4. 5 100.0%
Average (%)
99.8%
4. 6
Non-Smoke Test
Additive
Ecoburn
4. 7
4. 8
4. 9
4. 10
4. 11 97.3%
4. 12 94.7%
4. 13 72.8%
4. 14 69.1%
4. 15 Non-Trip
4. 16 61.1%
4. 17 32.4%
4. 18 19.3%
4. 19 29.1%
4. 20 19.2%
Average (%)
22.5% Last 3 days (4.18, 4.19, 4.20) Average
-
7/23/2019 Smoke Test at BMTA
21/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40300
-
7/23/2019 Smoke Test at BMTA
22/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40300
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 4. 7 4. 8 4. 9 4. 104. 114. 124. 134. 144. 154. 164. 174. 184. 194. 20
Non-Additive Ecoburn
-
7/23/2019 Smoke Test at BMTA
23/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40300
DATE
OPACITY PEAK VALUE AVERAGE (%)
REMARK
4. 1 Axis Differential Troble
Non-additive
Ecoburn
4. 2 79.4%
4. 3 89.9%
4. 4 99.1%
4. 5 99.1%
Average (%)
73.5%
4. 6
Non-Smoke Test
Additive
Ecoburn
4. 7
4. 8
4. 9
4. 10
4. 11 67.7%
4. 12 92.9%
4. 13 42.1%
4. 14 43.0%
4. 15 29.7%
4. 16 50.1%
4. 17
50.6%
4. 18 34.2%
4. 19 24.3%
4. 20 24.6%
Average (%)
27.7% Last 3 days (4.18, 4.19, 4.20) Average
-
7/23/2019 Smoke Test at BMTA
24/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40312
-
7/23/2019 Smoke Test at BMTA
25/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40312
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4. 1 4. 2 4. 3 4. 4 4. 5 4. 6 4. 7 4. 8 4. 9 4. 10 4. 11 4. 12 4. 13 4. 14 4. 15 4. 16 4. 17 4. 18 4. 19 4. 20
Non-additive Ecoburn Additive Ecoburn
-
7/23/2019 Smoke Test at BMTA
26/27
ECOBURN THAILAND CO., Ltd.
Car Number : BMTA 5 - 40312
DATE
OPACITY PEAK VALUE AVERAGE (%)
REMARK
4. 1 79.3%
Non-additive
Ecoburn
4. 2 74.9%
4. 3 78.3%
4. 4 87.5%
4. 5 97.2%
Average (%)
83.4%
4. 6
Non-Smoke Test
Additive
Ecoburn
4. 7
4. 8
4. 9
4. 10
4. 11 49.3%
4. 12 28.7%
4. 13 47.5%
4. 14 14.6%
4. 15 32.0%
4. 16 35.3%
4. 17
33.5%
4. 18 37.4%
4. 19 14.2%
4. 20 28.6%
Average (%)
26.7% Last 3 days (4.18, 4.19, 4.20) Average
-
7/23/2019 Smoke Test at BMTA
27/27
3. SMOKE TEST RESULT
ECOBURN INDUCES FULL COMBUSTION FOR ALL KIND OF FUEL, FIRSTLY
TAKING OUT CARBON DEPOSIT WITH POWER UP AND THEN LEADS TO FUEL
EFFICIENCY WITH REDUCTION OF SMOKES.
THE SMOKES OF 5 BUSES WERE REDUCED TO AROUND 60% AT THIS TEST.
ALL BUSES PARTICIPATED IN THE TEST WERE MADE 30 YEARS AGO.
ALL 5 BUSES PASSED THE FORMAL EMISSION TEST OF THAI GOVERNMENT
ON 20THAPRIL 2014.
ECOBURN THAILAND CO., Ltd.