sk tech co., ltd.20report/%b9%cc%bb%e7%bf%eb/... · the multi model no. is a trium-sh5004. the...

29

Upload: others

Post on 26-Apr-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 2 of 29

REVISION HISTORY

Rev. # Changes of Content Section Affected Reviewed by Date

0 Original Release All S.H.Yoon Nov. 8, 2010

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 3 of 29

SUMMARY OF TEST RESULT

EMISSION

STANDARD ITEM CLASS/SEVERITY RESULT

AC Power line Conducted Emission Test

Meets Class A limits and minimum passing margin is 20.27 dB at

0.17 MHz.

PASS

ANSI C63.4 / 2009 FCC Part 15 Subpart B

Radiated Emission Test

Meets Class A limits and minimum passing margin is 12.1 dB at

945.01 MHz.

PASS

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 4 of 29

》 Table of Contents 《 ⅰ Cover Page 1 ⅱ Revision History 2 ⅲ Summary of Test Results 3 Ⅳ Table of Contents 4 1. General 5 2. Facilities and Accreditations 5

2.1 Facilities 5 2.2 Accreditations 5 2.3 Test and Measurement Instruments Used 6

3. EUT Description 7 4. EUT Operating Condition 8

4.1 EUT Operating Modes 8 4.2 Ancillary Equipment 8 4.3 Interconnection and I/O cable 9 4.4 Configuration 10 4.5 Uncertainty 11

5. Test Results EMISSION 12 5.1 Conducted Disturbance at mains terminals 12 5.2 Radiated Disturbance 15

Appendices A1 Photographs of the test set-up 18 A2 EUT Photographs 20-29

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 5 of 29

1. General The tests listed in this report have been performed and the results recorded by SK Tech Co., Ltd. in

accordance with the procedures stated in each test requirement and specification. As a result, the

subject product has been verified to comply with each test specification. The test results relate only to

the items tested.

We attest to the accuracy of data. All measurements reported herein were performed by SK TECH

Co., Ltd. and were made under Technical Manager’s supervision. We assume full responsibility for the

completeness of these measurements and vouch for the qualifications of all persons taking them.

2. Facilities and Accreditations

2.1 Facilities All of the measurements described in this report were performed at SK Tech Co., Ltd located in 820-2,

Wolmoon Ri, Wabu-Up, Namyangju-Si, Kyunggi-Do, Korea.

The test site is constructed in conformance with the requirements of ANSI C63.4 and CISPR Publication

22. It complies with the Normalized Site Attenuation requirements given in ANSI/IEEE C63.4. The

measuring equipment conforms to CISPR 16 requirements for Electromagnetic Noise and Field Strength

Instrumentation.

2.2 Accreditations Our testing laboratories are accredited by the following accreditation bodies in accordance with

ISO/IEC 17025 for general requirements for the competence of testing and calibration laboratories.

Korea : KOLAS No.191

Germany : DAKKS DAT-P-076/97-02

USA : NVLAP Lab Code: 200220-0

The laboratories have been also notified to FCC by RRL as a Conformity Assessment Body, and

designated to perform compliance testing on equipment subject to Declaration of Conformity(DOC) and

Certification under Parts 15 and 18 of the FCC Rules.

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 6 of 29

2.3 Test and Measurement Instruments Used

• Conducted Disturbance

Name of Equipment Type S/N Calibrated until

EMI Receiver ESHS10 862970/019 07.2011

Artificial Mains Network ESH2-Z5 834549/011 07.2011

Artificial Mains Network ESH3-Z5 836679/018 07.2011

Impedance Stabilization Network ISN T8 24806 07.2011

• Radiated Disturbance

Name of Equipment Type S/N Calibrated until

EMI Receiver ESVS10 834468/008 07.2011

Amplifier 8447F 3113A05153 07.2011

Trilog-Broadband Antenna VULB9168 9168-230 07.2011

Antenna Turntable Driver 5907 91X518 N/A

Antenna Turntable controller 5906 91X519 N/A

EMI TEST RECEIVER ESPI7 101206 07.2011

Horn Antenna (1G~18G) 3115 00040723 04.2011

Pre-Amplifier AFS44-00101800-25-10P-44 1116321 12.2010

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 7 of 29

3. EUT Description The following information has been supplied by the applicant. The Multi Model No. is a Trium-SH5004. The difference of Multi Model No. is a OEM Model Name.

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 8 of 29

4. EUT Operating Conditions During testing, the EUT was powered with, 120 Vac/ 60 Hz. Input 120 Vac/ 60 Hz, Output DC 12V.

The worst case test configuration and mode of operation was used all testing. Unless otherwise noted

elsewhere in this report, this selection will apply to all testing.

4.1 EUT Operation Modes

The EUT was connected to the Color Video Monitor and LCD Monitor.

The Dome Camera’s Image was displayed on the Color Video Monitor and LCD Monitor.

(Internal Clock Frequency 54MHz)

4.2 Ancillary Equipment The EUT was tested while connected to the following representative configuration of ancillary

equipment necessary to exercise the ports during tests.

# Equipment Manufacturer Model No. Serial No.

1 Color Video Monitor HITRON SYSTEMS INC. CVM1054X M5020001

2 LCD Monitor TOP VICTORY

ELECTRONICS (FUJIAN) CO., LTD.

ELM-728 2925BJA021104

3 AC Adaptor (LCD Monitor) TPV Electronics Co., Ltd. ADPC12416BB 12416BG54738591

4 Dome Camera N/A N/A N/A

5 AC Adaptor (Dome Camera)

Suzhou Li Shin Electronic Co., Ltd. LSE0107A1236 A30712036257

6 Mouse(USB) Microsoft Corporation IntelliMouse

Optical USB and PS/2 Compatible

N/A

7 SENSOR Board N/A SENSOR B/D REV.0.02 N/A

8 Memory Stick MEMORIVE N/A N/A

9 AC Adaptor(EUT)SINO-AMERICAN

ELECTRONIC(SuZhou) CO., LTD.

SA142B-12V 00000099

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 9 of 29

4.3 Interconnection and I/O cables

START END Cable #

Name I/O Port Name I/O Port Length(m) Shielded/ Unshielded

1 EUT Power AC Adaptor 1.6 Unshielded

2 “ AC Adaptor AC Line 1.6 Unshielded

3 “ Video In Dome Camera 3.0 Shielded

4 “ Video Out Color Video Monitor 3.0 Shielded

5 “ VGA Out LCD Monitor 1.4 Shielded

6 “ Audio In/Out Color Video Monitor 3.0 Unshielded

7 “ LAN HUB 5.0 Unshielded

8 “ USB Memory Stick - -

9 “ USB Mouse 1.6 Shielded

10 “ Sensor In/ Alarm Out

SENSOR Board 3.0 Unshielded

11 “ Video In(x3) 75Ω Termination - -

12 Dome Camera Power AC Adaptor 1.5 Unshielded

13 “ AC Adaptor AC Line 1.5 Unshielded

14 LCD Monitor Power AC Adaptor 1.0 Unshielded

15 “ AC Adaptor AC Line 1.6 Unshielded

16 Color Video Monitor Power AC Line 1.6 Unshielded

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 10 of 29

4.4 Test Configuration For the actual test configuration, please refer to the related item-photographs of the test setup.

[ System Block Diagram of Test Configuration ]

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 11 of 29

4.5 Uncertainty

1) Radiated disturbances from 30 MHz to 1000 MHz at a distance of 3 m and 10 m Expanded

Uncertainty

U = k * Uc(xi) = 2 * 2.10 = 4.20 dB

The coverage factor k =2 yields approximately a 95% level of confidence. 2) Conducted disturbance from 150 KHz to 30 MHz using a 50 Ω/50 μH AMN Expanded

uncertainty

U= k * Uc(xi) = 2 * 1.57 = 3.14dB

The coverage factor k =2 yields approximately a 95% level of confidence.

※ When the measured emission is positioned within the range of the uncertainty of measurement

from the emission limit, the uncertainty of measurement shall be concerned as follow.

Compliance or non-compliance with a disturbance limit shall be determined in the following manner.

If Ulab is less than or equal to Ucispr

- Compliance is deemed to occur if no measured disturbance exceeds the disturbance limit;

- Non-compliance is deemed to occur if any measured disturbance exceeds the disturbance limit.

If Ulab is greater than Ucispr

- Compliance is deemed to occur if no measured disturbance, increased by (Ulab - Ucispr), exceeds

the disturbance limit;

- Non-compliance is deemed to occur if any measured disturbance, increased by (Ulab - Ucispr),

exceeds the disturbance limit.

※ If the measurement value is lower or equal to the limit, the EUT is considered to pass the test.

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 12 of 29

5. Test Results EMISSION 5.1 Conducted Disturbance at mains terminals

Result PASS

Temperature 21 ℃ Test Environment Humidity 24 % R.H.

Test Procedure

The line-conducted facility is located inside a 2.6 m x 3.6 m x 7.0 m shielded room. The shielding effectiveness of the shielded room is in accordance with MIL-Std-285 or NSA 604-05. A wooden table with 80 cm height is placed 40 cm away from the vertical conducting plane and 1.5 m away from the other side of the shielded room. A Line Impedance Stabilization Network(LISN) that provided a 50ohm/ 50µH coupling impedance are bonded to the shielded room. The EUT was connected to the mains power through a LISN that provided a 50 ohm/ 50 µH coupling impedance for the measuring instrument and the ancillary equipment was also connected to the mains power through the LISN that provided a 50 ohm/ 50 µH coupling impedance with 50 ohm termination. The EMI test receiver was set to frequency range from 150 kHz to 30 MHz and bandwidth at 10 kHz and detector as Quasi-Peak or Average. The AC power line conducted emission was measured between each power line and ground at the power terminal. The initial testing identified the frequency that has the highest emission relative to the limits while operating the EUT in typical modes of operation and cable positions in a test setup representative of typical system configuration. The identification of the frequency of highest emission with respect to the limit was found by investigating emissions at a number of significant frequencies. The probable frequency of maximum emission had been found and that the associated cable and EUT configuration and mode of operation had been identified.

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 13 of 29

Conducted Disturbance Test data <Quasi-Peak>

0.170 L 0.14 0.02 57.60 79.00 21.400.220 N 0.10 0.02 49.26 79.00 29.740.230 L 0.13 0.02 48.53 79.00 30.470.340 L 0.12 0.02 44.80 79.00 34.200.460 N 0.12 0.04 43.74 79.00 35.260.550 L 0.13 0.04 41.73 73.00 31.27

43.5841.56

57.4449.1448.3844.66

Frequency(MHz)

ReadingLine C/F

(dB)(dBμV)C/L(dB)

Actual(dBμV)

Limit(dBμV)

Margin(dB)

<Average>

0.170 L 0.14 0.02 45.73 66.00 20.270.220 N 0.10 0.02 33.80 66.00 32.200.230 L 0.13 0.02 36.42 66.00 29.580.340 L 0.12 0.02 33.89 66.00 32.110.460 N 0.12 0.04 32.40 66.00 33.600.550 L 0.13 0.04 29.87 60.00 30.13

32.2429.70

45.5733.6836.2733.75

Frequency(MHz)

ReadingLine C/F

(dB)(dBμV)C/L(dB)

Actual(dBμV)

Limit(dBμV)

Margin(dB)

NOTE

* C/F = Correction Factor

* C/L = Cable Loss

* LINE: L = Line-PE, N = Neutral-PE

* Margin Calculation

Margin (Q.P) = Limit - Actual

[Actual (Q.P) = Reading (Q.P) + C/F + C/L]

hong
hong

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 14 of 29

Spectral Diagram, LINE – PE

Spectral Diagram NEUTRAL – PE

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 15 of 29

5.2 Radiated Disturbance

Result PASS

Temperature 18 ℃ Test Environment Humidity 28 % R.H.

Test Procedure

The EUT was placed on a non-conductive table with 0.8 m height. The turntable

can rotate 360 degree to determine the position of the maximum emission level.

The EUT was set 10 meters away from the receiving antenna that was mounted

on a non-conductive master. The antenna can move up and down between 1 to 4

meters to find out the position of the maximum emission level. The floor of the

Open Area Test Site(OATS) is covered by a conductive metal ground plane and

OATS comply with the Normalized Site Attenuation requirements. The spectrum

was scanned from 30 to 1000 MHz using Trilog-Broadband Antenna. Above 1

GHz, linearly polarized double ridge horn antennas were used.

The initial testing identified the frequency that has the highest emission relative to

the limits while operating the EUT in typical modes of operation and cable

positions in a test setup representative of typical system configuration.

The identification of the frequency of highest emission with respect to the limit was

found by investigating emissions at a number of significant frequencies. The

probable frequency of maximum emission had been found and that the associated

cable and EUT configuration and mode of operation had been identified.

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 16 of 29

Radiated Disturbance Test data – below 1 GHz

Frequency Reading Pol. Height Amp Gain Correction Factor Data Limits Margin

[MHz] [dBμV ] [m] [dB] Antenna Cable [dBμV / m] [dBμV / m] [dB]

283.80 40.8 H 2.3 27.5 12.6 1.7 27.5 46.4 18.9

297.97 39.6 H 2.3 27.5 12.6 1.7 26.4 46.4 20.0

340.50 36.2 H 3.0 27.8 13.2 1.9 23.4 46.4 23.0

354.68 35.8 H 2.8 27.9 13.3 2.0 23.1 46.4 23.3

431.36 32.1 H 2.4 28.4 14.5 2.2 20.4 46.4 26.0

945.01 35.2 H 1.0 28.3 24.1 3.3 34.3 46.4 12.1

NOTES: 1. All other emission are non-significant.

2. Measurements using CISPR Quasi-Peak mode.

(Resolution bandwidth: 120 kHz)

3. H = Horizontal, V = Vertical Polarization.

4. Data = Real Reading – Amp Gain + Correction Factor (Antenna + Cable)

5. Margin = Limits - Data

6. Radiated Measurements at 10-meters.

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 17 of 29

Radiated Disturbance Test data – Above 1 GHz

Frequency Reading Pol. Height Amp Gain Correction Factor Data Limits Margin

[MHz] [dBμV] [m] [dB] Antenna Cable [dBμV / m] [dBμV / m] [dB]

* The test Results were under required limit with 20dB margin or more.

NOTES:

1. All other emission are non-significant.

2. Measurements using peak and average mode.

(Resolution bandwidth: 1 MHz, Video bandwidth: 1 MHz)

3. H = Horizontal, V = Vertical Polarization

4. Data = Real Reading – Amp Gain + Correction Factor (Antenna + Cable)

5. Margin = Limits – Data

6. Radiated Measurements at 10-meters

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 18 of 29

Appendices A1: Photograph of test set-Up A1.1: Conducted Disturbance

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 19 of 29

A1.2: Radiated Disturbance

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 20 of 29

A2: EUT Photographs A2.1: < Front >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 21 of 29

A2.2: < Rear >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 22 of 29

A2.3: < Internal >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 23 of 29

A2.4: < Main Board Front >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 24 of 29

A2.5: < Main Board Rear >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 25 of 29

A2.6: < HDD Front >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 26 of 29

A2.7: < HDD Rear >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 27 of 29

A2.8: < AC Adaptor(EUT) Front >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 28 of 29

A2.8: < AC Adaptor(EUT) Rear >

SK Tech Co., Ltd.

http://www.skemc.co.kr

SKTEFC-101108-109

SK Tech Co., Ltd. 820-2, Wolmoon-Ri, Wabu-Up

Namyangju-Si, Kyunggi-Do, 472-905, Korea Phone: +82-31-576-2204 Fax: +82-31-576-2205

Page 29 of 29

A2.8: < AC Adaptor(EUT) Label >