site investigation-for section 3.pdf
TRANSCRIPT
![Page 1: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/1.jpg)
Bahir Dar University, Bahir Dar Institute of Technology
Faculty of Civil and Water Resources Engineering
Department of Civil Engineering
Wubete M.
Mar,2016
1
Chapter 1:
Site Exploration
![Page 2: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/2.jpg)
2
Outline
Purpose of Soil Exploration
Different methods
– Test trenches and Pits
– Auger and Wash Boring
– Rotary Drilling
– Soil Sampling (Disturbed and Undisturbed)
– Geophysical Methods
![Page 3: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/3.jpg)
3
Site Exploration
• Investigation of a site for obtaining information about the
subsurface conditions that underlain a proposed structure
• Determination of surface and subsurface soil conditions and
features in an area of proposed construction that may influence
the design and construction and address the expected post
construction problems.
• It consists of determining the profile of the natural soil deposits
at the site, taking the soil samples and determining the
engineering properties of soils. It also includes in-situ testing of
soils.
![Page 4: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/4.jpg)
4
Scope of Exploration
• Simple visual examination of the soil at the surface or from
shallow test pits
• Detailed study of soil and groundwater to a reasonable
depth( influence zone) by sampling from boreholes and in-
situ and laboratory tests
![Page 5: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/5.jpg)
5
Purpose of Exploration
The site exploration provides first hand information for;
• Selection of alternative construction site or choice of
most economical site
• Design of foundations
– to decide the type and depth
– Estimating the load bearing capacity and
probable settlement
• Contractors to quote realistic and competitive
tenders
• Planning construction techniques.
• Groundwater location
![Page 6: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/6.jpg)
6
Purpose of Exploration
• Selection of appropriate construction equipment and
materials (especially for excavation and foundations).
• Study of environmental impacts (EI) of the proposed
construction.
• Selection of the most suitable and economical route for
highways with respect to soil conditions.
• The investigation of the cases where failure has occurred, to
know the causes and design of remedial works
• Need for any suitable soil improvements
![Page 7: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/7.jpg)
7
Common Steps in Site Exploration
Desk Study
Site Reconnaissance
Field Investigations
a) Preliminary Ground Investigation
b) Detailed Ground Investigation
Laboratory Testing
Report Writing
Follow up Investigations during design & construction
Appraisal of performance
![Page 8: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/8.jpg)
Reconnaissance
Its purpose is to estimate the type of soils and rock likely to be
encountered and is accomplished by:
• Collection of data about the project
• Visual inspection of the site condition (topography) and
nearby existing structures
• Geologic study: Geological map, Area Photographs
• Collecting and studying the existing document from
previous experience with similar or adjacent sites.
8
![Page 9: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/9.jpg)
Reconnaissance
Cracks, sticking doors and windows in existing light building
Expansive soils
9
![Page 10: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/10.jpg)
Potential Stability Problems10
![Page 11: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/11.jpg)
11
![Page 12: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/12.jpg)
What can you detect from photo inspection?
12
![Page 13: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/13.jpg)
Preliminary Site Investigation
A few borings or a test pit to establish the stratification,
types of soil to be expected, and possibly the location of the
groundwater level and its fluctuation.
Depth of bed rock , If the initial borings indicate the upper
soil is loose or highly compressible.
Establish subsurface profile (depth, thickness and
composition of subsurface strata).
Estimate of engineering properties of the soil from index
properties
13
![Page 14: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/14.jpg)
Preliminary Site Investigation
Initial selection of foundation possibilities.
This step may be sufficient to establish the foundation criteria
for small projects
14
![Page 15: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/15.jpg)
Detailed Site Investigation
If the preliminary site investigation get feasible, detailed
investigation is undertaken
Additional borings are required
Determine the specific appropriate engineering properties of
the site soil (strength, compressibility and hydraulic
conductivity)
More sounding field tests undertaken to obtain information
which shall be sufficient for final design
15
![Page 16: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/16.jpg)
16
Methods of Site Exploration
The methods to determine the sequence, thickness and lateral
extent of the soil strata and, where appropriate the level of bedrock.
The common methods include
Test pits /trenches
Boring (and sampling) or drilling
Insitu Tests
Laboratory Tests etc
![Page 17: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/17.jpg)
17
• The excavation of test pits is a simple , cheapest and reliable
method.
• The depth is limited to 4-5m only.
• The in-situ conditions are examined visually
• It is easy to take good undisturbed soil samples from a pit
than a bore hole
• Block samples can be cut by hand tools and tube samples
can be taken from the bottom of the pit.
• Trenches are useful in investigating subsurface conditions
where lateral variations in material conditions are expected
Test Pits and Trenches
![Page 18: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/18.jpg)
** Block Samples
Block samples are cut by hand from material exposed in trial pits
and excavations.
Sample cutting should be done as quickly as possible to prevent
excessive moisture loss, should be protected from rain and direct
sunlight.
Protect the sides with aluminum foil or grease proof paper and
coated with wax and cover with muslin.
18
![Page 19: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/19.jpg)
Sample Labeled, Moisture Control and Transportation
Seal with wax to control
water content of samples
Vertical transportation to prevent
moisture migration
![Page 20: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/20.jpg)
What’s wrong with this sampling?
![Page 21: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/21.jpg)
21
Boring refers to advancing a hole in the ground.
Boring is required for the following:
• To obtain representative soil and rock samples for
laboratory tests.
• To identify the groundwater conditions.
• Performance of in-situ tests to assess appropriate soil
characteristics.
Boring
![Page 22: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/22.jpg)
22
Some of the common types of boring are as follows
Auger boring
Wash boring
Percussion boring
Rotary drilling
Boring
![Page 23: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/23.jpg)
23
![Page 24: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/24.jpg)
24
Hand Auger
It is the simplest method of boring used for small projects in soft
cohesive soils.
For hard soil and soil containing gravels boring with hand auger
becomes difficult.
• It can be used for depths up to 3 to 5m..
• The length of the auger blade varies from 0.3-0.5m.
• The auger is rotated until it is full of soil, then it is withdrawn to
remove the soil and the soil type present at various depths is noted.
24
Hand Auger Mechanical Auger
Auger Boring
![Page 25: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/25.jpg)
25
• The soil samples collected in this manner are disturbed samples and
can be used for classification test.
• Generally, it is suitable for all types of soils above water table but
suitable only for clays below the water table.
• Auger boring may not be possible in very soft clay or coarse
sand because the hole tends to collapse when auger is removed.
• Soils with boulders and cobbles are difficult to investigate.
25
Auger Boring
![Page 26: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/26.jpg)
26
26
Auger Boring
![Page 27: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/27.jpg)
27
Mechanical Auger means power operated augers. The power
required to rotate the auger depends on the type and size of
auger and the type of soil.
Downwards pressure can be applied hydraulically, mechanically
or by dead weight
a
ab
c d
a. Continuous Flight Auger
b. Hollow-stem auger plugged
during advancing bore
c. Plug removed and sampler
inserted
d. Truck mounted auger boring
machine
Mechanical Auger
![Page 28: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/28.jpg)
28
• The most common method is to use continuous flight augers.
Continuous flight augers can be solid stem or hollow stem with
internal diameter of 75-150mm.
• Hollow stem augers are used when undisturbed samples are
required. Plug is withdrawn and sampler is lowered down and driven
in to the soil below the auger.
• If bed rock is reached drilling can also take place through the hollow
stem.
• As the auger acts as a casing it can be used in sand below water
table. The possibility of rising sand in to the stem by hydrostatic
pressure can be avoided by filling the stem with water up to the
water table
![Page 29: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/29.jpg)
There is a possibility that different soil types may become
mixed as they rise to the surface and it may be difficult to
determine the depths of changes of strata. Experienced
driller can however detect the change of strata by the
change of speed and the sound of drilling.
Disadvantages of auger:
• The soil samples a re highly disturbed
• It becomes difficult to locate the change in strata
29
![Page 30: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/30.jpg)
30
Wash boring Water with high pressure pumped through hollow boring rods is
released from narrow holes in a chisel attach to the lower end of the
rods. The soil is loosened and broken by the water jet and the up-
down moment of the chisel.
The soil particles are carried in suspension to the surface between
the rock and the borehole sites.
The rods are raised and drop for chopping action of the chisel by
means of winch.
This method best suits in sandy and clayey soils and not in very hard
soil strata (i.e. boulders) and rocks.
Wash boring can be used in most type of soil but the progress is
slow in coarse gravel strata. 30
![Page 31: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/31.jpg)
31
Wash boring
31
![Page 32: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/32.jpg)
32
• Primarily intended for investigation in rock, but also used in
soils.
• The drilling tool, (cutting bit or a coring bit) is attached to the
lower end of hollow drilling rods
• The coring bit is fixed to the lower end of a core
• Water or drilling fluid is pumped down the hollow rods and
passes under pressure through narrow holes in the bit or
barrel
• The drilling fluid cools and lubricates the drilling tool and
carries the loose debris to the surface between the rods and
the side of the hole.
Rotary Boring/ Drilling
![Page 33: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/33.jpg)
33
Advantages
The advantage of rotary drilling in soils is
• The progress is much faster than with other investigation
methods
• Disturbance of the soil below the borehole is slight.
Limitations
The method is not suitable if the soil contains a high percentage
of gravel/cobbles, as they tend to rotate beneath the bit and are
not broken up.
The natural water content of the material is liable to be
increased due to contact with the drilling fluid
![Page 34: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/34.jpg)
34
No “hard-and-fast rule” exists for determining the number
of borings or the depth to which the test borings are to be
advanced.
For most buildings, at least one boring at each corner and
one at the center should provide a start for investigation in
rock, but also used in soils.
Depending on the uniformity of the subsoil, additional test
borings may be made
Site Exploration Range
![Page 35: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/35.jpg)
How Many Borings?
Conventionally, the number (density) of borings will
increase:
• As soil variability increases
• As the loads increase
• For more critical/significant structures
35
![Page 36: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/36.jpg)
36
Numbers of Borings
Guideline for trial pits and boring layout (Teng)
7.5
![Page 37: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/37.jpg)
How many bore holes?
37
120 m
Proposed site for a multi-story shopping complex
Not enough bore holes; soil profile and properties not well defined..Not enough bore holes; soil profile and properties not well defined..
bore hole
![Page 38: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/38.jpg)
120 m
Too many bore holes and blows the budget.Too many bore holes and blows the budget.
How Many Bore Holes?
38
![Page 39: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/39.jpg)
How many bore holes?
39
120 m
About right?About right?
trial pit
![Page 40: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/40.jpg)
40
According to Tomlinson
i. For widely spaced strip of pad foundation, Boring depth depth(D)
1.5B
ii. For Raft Foundations, depth(D) 1.5B, B-width of foundation
iii. For closely spaced strip or pad foundations where there is
overlapping of the zones of pressure, D 1.5 width of building
iv. For group of piled foundation on soil, D 1.5 width of pile group.
The depth being measured from a depth of two-thirds of the
length of piles
v. For piled foundation on rock, D 3.0m inside bedrock.
Depth of Borings
![Page 41: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/41.jpg)
41
According to EBCS 7,1995
Depth of Borings
b.For structures on footing,
B
D
DBB
D
DB
BH BH
3
c.For structures piled foundation,
D pile length from the surface B m
a.For structures on
mat foundation,
![Page 42: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/42.jpg)
Depth of Investigation Based on Pressure Bulb
42
Must explore to the depth to which the soil
will be significantly stressed (perhaps to
10% of the applied stress). This is of the
order of twice the width of the loaded area.
Isolated footing
Pile group
Stress contours
Soil stressed to greater depth due
to interaction between piles and
due to shaft friction
![Page 43: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/43.jpg)
43
Depth of Investigation-Based on Pressure Bulb
![Page 44: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/44.jpg)
44
Depth of Investigation -Based on Pressure Bulb
Closely spaced strip on pad footings
![Page 45: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/45.jpg)
45
Depth of Investigation -Based on Pressure Bulb
![Page 46: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/46.jpg)
Minimum boring depth, D
ASCE(1972)
1. Determine the net increase in the effective stress Ds’ and the
vertical effective stress s0’
2. Determine D1 when Ds’= q/10
3. Determine D2 when Ds’= s0’ /20
4. Find D = min(D1 and D2)
q
46
![Page 47: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/47.jpg)
Sowers and Sowers(1970)
Rough estimate of min. depth of borings, D( unless bedrock is
encountered) is as follows:
1. D = 3S 0.7 …… for light steel or narrow concrete building
2. D = 6S 0.7 …… for heavy steel or wide concrete building
Where D = approximate depth of boring for preliminary
investigation
S = number of stories
47
![Page 48: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/48.jpg)
Two problems that are common to the drilling of holes
i. Caving of the sides of the hole
Caused by the release of the stresses caused by the
removal of overburden material from the hole
Holes drilled above the water table may not cave in even
in sandy soil due to the presence of apparent cohesion
present between particles
Caving in sandy soils cannot be avoided below the water
table.
Holes drilled in cohesive soil may remain stable even up to
considerable depth below the water table.48
Stabilization of bore Holes
![Page 49: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/49.jpg)
Caving in fine sandy and silty soils below water table can be
minimized to certain extent by use of drilling mud
a. Drilling mud … Bentonite( pure form of thixotropic
clay) mixed with water. i.e. Bentonite Slurry, which has
the following properties
Supports the excavation by exerting hydrostatic pressure
on the wall
Provide almost instantaneously a membrane with low
permeability
b. Use of casing pipe49
Stabilization of bore Holes
![Page 50: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/50.jpg)
Caving of the sides of the hole can be prevented by
a. Drilling mud … Bentonite( pure form of thixotropic
clay) mixed with water. i.e. Bentonite Slurry, which has
the following properties
Supports the excavation by exerting hydrostatic pressure
on the wall
Provide almost instantaneously a membrane with low
permeability
b. Use of casing pipe
50
Stabilization of bore Holes
![Page 51: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/51.jpg)
51
Stabilization of bore Holes
Regained strength of a partially thixotropic material
Heaving of the bottom of the hole can be prevented by
a. Keeping the water table in the hole sufficiently above the
water table outside the hole to counteract the inflow
![Page 52: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/52.jpg)
There are 2 main categories of soil samples:
- Undisturbed samples .
The soil structure, and particle size distribution should be preserved
to its original Insitu stratum.
The water content of the samples are also tried to be
preserved as far as possible, to truly represent site conditions.
These samples are required for carrying out tests in lab.: shear
strength, consolidation, permeability, compressibility, Insitu-
density and water content…
52
Soil Sampling & Sample Disturbance
![Page 53: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/53.jpg)
- Disturbed samples.
The particle size distribution should be preserved to its original Insitu
stratum (representative), though the soil structure may be seriously
disturbed
The water content of the samples may have also changed. If it
is permissible, the water content should also be preserved.
Collected as drilling or digging progress for soil identification
and classification(Index Properties).
Tests that can be conducted: Chemical Analysis, Atterberg’s
Limit, Sieve analysis, Sp.Gravity, compaction etc.
53
Soil Sampling & Sample Disturbance
![Page 54: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/54.jpg)
- Disturbance of samples is due to.
The change in state of stress as the sample is retrieved
from the soil
Resistance against the sides of the sample
During transportation to the laboratory
As the sample is retrieved from sampling tube
Evaporation of moisture from the sample due to improper
sealing
54
Soil Sampling & Sample Disturbance
![Page 55: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/55.jpg)
To reduce side friction onsample as tube is pushed intothe soil
Sample Disturbance
The degree of disturbance can be expressed in terms of area ratio
55
![Page 56: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/56.jpg)
Sample Disturbance
56
Area ratio is the ratio of the volume
of soil displaced to the volume of
collected sample
![Page 57: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/57.jpg)
57
Good quality samples necessary.
AR≤ 10%
sampling tube
soil(%) 100
..
....2
22
DI
DIDOAR
area ratio
Thicker the wall, greater the disturbance.
Soil Sampling & Sample Disturbance
The disturbance is considered negligible
![Page 58: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/58.jpg)
Sample Disturbance
58
The soil sample can be considered undisturbed If the area ratio is less
than or equal to 10% , the disturbance is considered negligible
However , area ratio have to be much more than 10 % for very stiff
or hard clay soils to prevent the edges of the sampling tube from
getting distorted during sampling
Inside clearance allows for elastic expansion of the soil as it enters
the tube, and thus produces disturbance of soil structure and
reduction of density in dense sand .to minimize the expansion and
disturbance of soil sample , inside clearance should not be more than
1 to 3%
Inside clearance reduces frictional drag on the sample from the wall
of the tube and helps to retain the cores
![Page 59: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/59.jpg)
Sample Disturbance
59
The outside clearance should also not be much greater than inside
clearance. It is usually between 0 to 2%.
Outside clearance facilitates the withdrawal of the sample from the
ground
![Page 60: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/60.jpg)
Common types of samplers
i. Split-Spoon- With these sampler-disturbed samples of
soft rock, cohesive and cohesionless soils are obtained.
This sampler is used for making standard penetration.
ii. Thin –wall tube(shelly tube) –for soils sensitive to
disturbance and suitable to take undisturbed sample only
for cohesive soils( clays/silt)
iii. Piston sampler - For very soft silts and clays and
provides best-undisturbed sample of cohesive soils
60
Sampling Methods
![Page 61: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/61.jpg)
For Standard Split-Spoon Sampler Di=1.38in, Do=2in
• AR(%)=111.5%>10%
• disturbed sample
• used for soil tests to obtain soil index properties
For Thin-Walled Tube (Shelby tube) Sampler Di=1.875in, Do=2in
• AR(%)=13.75%>10%
• Relatively undisturbed sample
• used for soil tests to obtain soil engineering properties
This indicates that thesample collected bySplit-spoon is highlydisturbed
61
![Page 62: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/62.jpg)
These test are used to determine the properties of the soil without
disturbing effect of boring and sampling. The most commonly used field
tests are:
Penetration or sounding Test
Vane Shear Test
Plate Loading test
Pile Loading Test
Dutch Cone Penetration
62
In-situ Tests
![Page 63: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/63.jpg)
63In bore holes
VST
SPT
CPT
63
![Page 64: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/64.jpg)
Penetration tests are conducted mainly to get information on
the relative density of soils with little or no cohesion.
The tests are based on the fact that the relative density of a
soil stratum is directly proportional to the resistance of the soil
against the penetration of the drive point.
From this, correlations between values of penetration
resistance versus angle of internal friction ), bearing
pressure, density have been developed.
64
In-situ Tests
![Page 65: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/65.jpg)
Standard Penetration Test
SPT
65
![Page 66: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/66.jpg)
This is the most commonly used in-situ test, especially for
cohesionless soils which cannot be easily sampled.
The test is extremely useful for determining the relative density
and the angle of internal friction of cohesionless soils.
It can also be used to determine the unconfined compressive
strength of soils..
The sampler is driven into the soil by hammer blows to the top
of the drill rod, the number of blows required for the last two
intervals are added to give the standard penetration number, N
66
Standard Penetration Test(SPT)
![Page 67: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/67.jpg)
Standard Penetration Test
The blows required to produce the first 150mm penetration,
termed as seating blows, are usually ignored as it is
assumed that it is disturbed due to drilling process. The test is
refusal and halted if
a. 50 blows are required for any 150-mm increment
b. If a total of 100 blows are obtained to drive the required 300mm
c. 10 successive blows produce no advance
67
![Page 68: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/68.jpg)
Standard Penetration Test
![Page 69: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/69.jpg)
Energy Ratio
It is necessary to standardize SPT to some energy ratio(Er),which
is the ratio of the actual hammer energy to the sampler to input
energy.
Energy ratio (Er) x blow count should be constant for any soil and
can be expressed as
r1 1 r2 2E N =E N
This indicates that the larger values of energy ratio
decreases the blow count linearly
69
100 ar
in
Actual Hammer energy to sampler, EE
Input energy, Ex
![Page 70: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/70.jpg)
Corrections to Measured SPT Value
In the field, the energy can vary from 30% to 90%.
The discrepancies appear to be rise from the ff factors:
Difference in some features of SPT equipment, drilling rig,
hammer and skill of operation
Driving hammer configuration and the way hammer load is
applied
Whether liner is used inside the split barrel sampler… Side
friction increases the driving resistance (N)
70
![Page 71: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/71.jpg)
Corrections to Measured SPT Value
overburden pressure- the bigger the o.b.p the more is N
value for soil of the same density.
Degree of cementation: The more cemented zone the
higher is N value
Length of the drill rod- the shorter the rod the more is N
value
Bore hole diameter - the smaller the size of the hole the
more is N value
71
![Page 72: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/72.jpg)
Corrections to Measured SPT Value
So, the standard practice now is to express the N-value to an
average energy ratio of 60% , i.e. N60 (Skempton 1986)
N60 is used to correlate the soil properties of cohesive soil
( e.g. qu, Su, OCR etc. )
60 N C C C Cm E B S RN
where:
CE: Hammer Energy ratio (Er) factor (efficiency)=actual energy
ratio/Standard energy ratio (60%)
CB: correction for borehole diameter
CS: sampler correction
CR: correction for rod length
Nm: measured SPT N value
72
![Page 73: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/73.jpg)
Skempton 1986
73
![Page 74: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/74.jpg)
Correction for Overburden Pressure
This type of correction is applied only to Cohesionless soils. The
Correction suggested by Liao and Whitman (1986) is as follows:
'60 60N C NN
N
v
95.76C =
σ
where:
CN: Adjustment for effective overburden pressure
s’v(kPa): in-situ effect vertical stress
74
![Page 75: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/75.jpg)
Terzaghi and Peck considered dilatancy correction for N>15,which is
an indication of Dense sand.
In such soil, the fast rate of application of shear through the blows
of hammer, is likely to induce negative pore water pressure in
saturated fine sand under undrained loading condition
Correction for Dilatancy
Corrections to Measured SPT Value
75
![Page 76: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/76.jpg)
Saturated Sands that contain appreciable fine soil particles such as
silty or clayey sands could give abnormally high N values if they
have the a tendency to dilate or abnormally low N Values if they have
tendency to contract during undrained shear conditions associated
with driving SPT.
Silty fine sands and fine sands below the water table develop pore
water pressure which is not easily dissipated. The pore water pressure
increases the resistance of the soil and hence the penetration number
(N).
Correction for Dilatancy
Corrections to Measured SPT Value
76
![Page 77: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/77.jpg)
Terzaghi and peck (1967) recommend the following correction
N'' = 15+ 0.5(N'-15)
where:
N’’= corrected value
N’= Value obtained after overburden correction
Correction for Dilatancy
For N’ >15 …..Terzaghi and Peck
N'' = N' for N' 15.0
Corrections to Measured SPT Value
77
![Page 78: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/78.jpg)
Terzaghi and Peck(1974)
In current practice the correction for water table is ruled out due to
its conservative nature
Correction for Water Table
Corrections to Measured SPT Value
1
DwCw= 0.5
D+B
where:
D = Depth of footing base from surface
Dw=Depth of water table from surface
78
![Page 79: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/79.jpg)
79
N60 cu (kPa) consistency visual identification
0-2 0 - 12 very soft Thumb can penetrate > 25mm
2-4 12-25 soft Thumb can penetrate 25mm
4-8 25-50 medium Thumb penetrates withmoderate effort
8-15 50-100 stiff Thumb will indent 8 mm
15-30 100-200 very stiff Can indent with thumbnail; not thumb
>30 >200 hard Cannot indent even withthumb nail
Use with caution; unreliable.
not corrected for overburden
79
![Page 80: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/80.jpg)
80
(N)60 Dr (%) (deg) consistency
0-4 0-15 <28° very loose
4-10 15-35 28-30° loose
10-30 35-65 30-36° medium
30-50 65-85 36-42° dense
>50 85-100 >42 very dense
not corrected for overburden
80
![Page 81: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/81.jpg)
The relative density is useful to describe the consistency of sand. It
may be determined from SPT data using the following empirical
correlations(Kulhawy and Mayne 1990)
0.18
100
t
1 60
A OCR
50
A
OCR
NDr = X100%
CpC C
Cp = 60 + 25logD
C = 1.2 + 0.05log
C = OCR
where:
Dr= relative density
(N1) 60 = SPT N value corrected for field procedures and overburden stress
Cp=grain-size correction factor
CA= aging correction factor
COCR =overconsolidation correction factor
D50 =grain size at which 50% of the soil is finer(mm)
t= age of soil(time since deposition((years)
OCR=overconsolidation ratio
81
![Page 82: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/82.jpg)
82
![Page 83: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/83.jpg)
Cone Penetration Testing(ASTM D 5778)
Cone Penetration Test is a static in-insitu test used for
subsurface exploration in fine and medium sands, soft silts and
clays without taking soil samples
The test is not well adapted to gravels deposits or to stiff/hard
cohesive deposits.
The corrected total tip resistance can be estimated as:
(1 )t cq = q cu a
where:
qt= corrected total cone resistance
qc = Qc/Ac =cone resistance
Qc=force required to push the cone
Ac= end area of the cone
a=net area ratio
uc =measured pore water pressure immediately behind the cone
83
![Page 84: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/84.jpg)
Cone Penetration Testing(ASTM D 5778)
84
![Page 85: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/85.jpg)
Cone Penetration Testing(ASTM D 5778)
Friction sleeve resistance can be estimated as:
where:
Qs= Force on friction sleeve
As = Area of friction sleeve
Friction Ratio
sf = Qs
As
f = fs
Rqc
85
• The CPT defines the soil profile with much greater resolution than SPT does
• However the CPT has disadvantagesa. No soil sample is recovered . So there is no opportunity to
inspect the soilb. The test is unreliable in soils with significant gravel content
![Page 86: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/86.jpg)
Cone Penetration Testing (ASTM D 5778)
ASTM D 577886
![Page 87: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/87.jpg)
0
5
10
15
20
25
30
35
40
0 10 20 30 40 50
qt (MPa)D
ep
th (
m)
0
5
10
15
20
25
30
35
40
0 100 200 300 400
fs (kPa)
0
5
10
15
20
25
30
35
40
0 1000 2000 3000
u2 (kPa)
Clean
Sand
Clayey Silt
Clay
Sand
87
![Page 88: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/88.jpg)
Cone Penetration Testing
88
![Page 89: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/89.jpg)
The undrained shear strength Friction sleeve resistance can be
estimated as:
Where: po=overburden pressure above the tip of the
cone and it is in the same unit of qc and
same type of pressure
Nk= cone factor(constant for soil)
With adjustment
CPT Correlations for Cohesive soils
cu
qs =
k
Po
N
u
qs = t
kt
Po
N
For normally consolidated clay oflow sensitivity (S<4) and PI <30, avalue of Nk=18 may be used
89
For normally consolidated clay oflow sensitivity (S<4) and PI <30, avalue of Nkt=14 may be used
5.513 2
50 kTN = PI Bowles (1996)
![Page 90: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/90.jpg)
CPT Correlations for Cohesive soils
90
![Page 91: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/91.jpg)
CPT Correlations for Non Cohesive soils
The design friction angle can be estimated as follows
5 c= 29 + q - for silty sand
+ for gravel
91
Bowles (1996)
![Page 92: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/92.jpg)
CPT Correlations
92
![Page 93: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/93.jpg)
Comparisons of SPT and CPT
93
![Page 94: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/94.jpg)
– Core recovery percentage
– Rock Quality Designation (RQD)
Defines the fraction of solid core recovered greater
than 4 inches in length
Calculated as the ratio of the sum of length of core
fragments greater than 4 inches to the total drilled
footage per run, expressed as a percentage
Rock Sampling
94
![Page 95: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/95.jpg)
Rock core drilling is commonly used to advance the borehole and
provide core samples for examination and testing
Core Recovery ,Lr is a measure of determining sample disturbance
and can be expressed as :
Rock Quality Designation(RQD) is an index or measure of the quality
of a rock mass [Stagg and Zienkiewicz(1698)].
Rock Coring
Length of recovered sampleCore recovery(%)= x100
Length of rock cored
Lengths of intact pieces of core>100mmRQD(%)= x100
length of core advance
95
![Page 96: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/96.jpg)
Recovery ratio, Lr is a measure of determining sample
disturbance and can be expressed as :
Lr = 1.0 … a good recovery
Lr > 1.0 indicates swelling in the sample
Lr < 1.0 means the sample is compressed
96
![Page 97: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/97.jpg)
9cm
97
![Page 98: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/98.jpg)
Fairly reliable results for the undrained shear strength, cu (=0
concept), of very soft to medium cohesive soils may be obtained
directly from vane shear tests
Shear vane apparatus.
3/10/201698
Vane Shear Test
![Page 99: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/99.jpg)
(a) resisting moment of shear force ; (b) Assumed variation in shear
strength mobilization3/10/2016
99
Vane Shear Test
![Page 100: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/100.jpg)
Calculation of Undrained Shear strength for Rectangular-Shaped ends Vane
3/10/2016100
Vane Shear Test
dA=rddr
Su
SuSuo
ab
c
d
![Page 101: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/101.jpg)
T = Ms + Me + Me
For calculation of Me, let the distribution of mobilized shear strength
follows triangular and then we can develop an equation for others.
3/10/2016101
Vane Shear Test
Two ends
• The resisting moments can be given as:
21(2 )
2sM RH Su R D HSu
2
00
R
e uo
r
M rS dA
![Page 102: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/102.jpg)
where and
3/10/2016102
Vane Shear Test
dA rd dr uo u
rS S
R
32 2
0 00 0
23
00
42
00
42
0
42
0
=
=4
=4
=4
=
R R
e u u
r r
R
u
r
R
u
r
u
u
r rM rS rd dr S d dr
R R
Sr d dr
R
S rd
R
S Rd
R
S R
R
3
u
πD×S
16
2
uo u
rS S
R
![Page 103: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/103.jpg)
From above equation
3/10/2016103
Vane Shear Test
2
2
2
1 2
2
1
2 8
1
2 4
s eT M M
D HSu
S D H
a
u
3
u
3
3
2 3 2 3
2
TSu
πD×S
16
πD
T T
⇒Su= =D H D D H D
π + π +
=D H D
π
2 8
⇒
+2 4
2
2
2
1 , 2 ,vh
2
s eT M M
D HSu vv3
u
πD×S
16
Anisotropic with respect to shear strength
![Page 104: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/104.jpg)
=1/2 for triangular end shear
= 2/3 for uniform end shear
= 3/5 for parabolic end shear
3/10/2016104
Vane Shear Test
2 3
TSu=
D H Dπ +a
2 4
where a=constant
⇒ For rectangular end vane
2 3
2 6
Su=
T
D H DFor rectangular shaped end
vane and uniform end shear,
both ends of vane are fully
submerged
![Page 105: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/105.jpg)
105
105
The Undrained Shear strength obtained from Vane shear test may
give results that are unsafe( overestimated) for foundation design.
Therefore reduction factor should be used
=1.7-0.54log(PI) ……Bjerrum(1974)
=1.05-0.045(PI)0.5 ……Chandler(1998)
Vane Shear Test
(design) (Vane shear)Su = Su
![Page 106: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/106.jpg)
106
![Page 107: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/107.jpg)
107
General Expression
![Page 108: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/108.jpg)
108
108
Plate Load Test
![Page 109: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/109.jpg)
109
109
It is the most reliable method to determine the bearing
capacity and the settlement at site
Plate Load Test
2
( 0.3)............f
( 0.3)
.....
p
p
b bp
bp b
b
bp
S= or footing rest on sand
S
S= for footing rest on clay
S
where :
S= Settlement of proposed foundation
Sp= settlement of test plate
bp= width(diameter) of plate
b=width of proposed footing(least dimension)
![Page 110: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/110.jpg)
110
110
For a given maximum permissible settlement, Sp can be
calculated using the eqn.
From the load-settlement curve the load intensity under the
plate could be read
The ultimate bearing capacity is determined as follows:
Plate Load Test
,
,
,
,
............
1.0.....
= for footing rest on sand soils
for footing rest on clay soils
u F
u p
u F
u p
q b
q bp
q
q
![Page 111: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/111.jpg)
111
111
Limitation of Plate Load Test
![Page 112: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/112.jpg)
112
112
Seismic Refraction Method
When a shock or impact is made at a point on or in the earth,
the resulting seismic (shock or sound) waves travel through
the surrounding soil at speeds related to their elastic
characteristics
The radiating waves are picked up by detector called
geophones placed at increasing distance from the origin of
shock
Geophysical Method
![Page 113: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/113.jpg)
113
![Page 114: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/114.jpg)
114
![Page 115: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/115.jpg)
115
115
Seismic Method
![Page 116: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/116.jpg)
116
116
Geophysical Method
![Page 117: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/117.jpg)
117
117
Geophysical Method
![Page 118: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/118.jpg)
118
118
Limitations
The basic eqns. Made is based on assumption that P-wave velocity
V1<V2<V3
The methods cannot be used when hard layer overlies a soft layer
The method cannot be used in an area covered by concrete of
pavement
When soil is saturated , the p-wave velocity is deceptive
This methods are used as preliminary or supplementary to others
Geophysical Methods
![Page 119: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/119.jpg)
119
119
![Page 120: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/120.jpg)
120
Establishing the highest and the lowest possible levels of
water during the life of the project is necessary.
In soils with high coefficient of permeability, the level of
water in bore hole will stabilize in a bout 24 hrs after
completion of the bore hole drilling.
The depth of the water table can then be measured
using a chalk coated steel tape.
Groundwater Table Location
![Page 121: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/121.jpg)
121
121
In soils with low K-values, this process may take a
week.
The depth of the water table can then be measured
by installing piezometer
If the seasonal ground water table variation is to be
measured, piezometer may be installed in to bore hole
and the variation is recorded for longer time.
Groundwater Table Location
![Page 122: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/122.jpg)
122
122
Laboratory tests are useful in providing reliable data for
calculating ultimate bearing capacity of soils, stability and
settlement behavior of foundation, and for determining physical
characteristics of soils. Results of laboratory tests should be
used in conjunction with borehole records and results of field
test.
The common laboratory tests that concern the foundation
engineers are
Grain size analysis –ASTM D422
Classification-ASTM D2487
Atterberg limits –ASTM D4318
Natural moisture content –ASTM D2216
Laboratory Tests
![Page 123: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/123.jpg)
123
123
Unit weight
Specific gravity-ASTM D854
Unconfined compression test –ASTM D2166
Direct shear test –ASTM D3080
Triaxial compression test
Unconsolidated Undrained--ASTM D2850
Consolidated Drained--ASTM D7181
Consolidated Undrained--ASTM D4767
Consolidation test—ASTM D2435
Compaction
Standard---ASTM D698
Modified--ASTM D1557
Laboratory Tests
![Page 124: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/124.jpg)
124
124
1. Introduction: - purpose of investigation, type of
investigation carried out.
2. General description of the site: - general configuration and
surface features of the site.
3. General geology of the area:- from available geology
records a summary of the geology and other relevant
conditions of the site are described since these could affect
the scope of the work
4. Details of the field exploration program, indicating the
number of borings, their location and depth.
5. Details of the methods of exploration.
Soil Exploration Report
![Page 125: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/125.jpg)
125
125
6. Description of soil conditions found in bore holes (and test
pits):- A brief summary of the sequence of deposits their
nature, thickness and variability.
7. Discussion of laboratory test results.
8. Discussion of results of investigation in relation to foundation
design and constructions.
9. Recommendations on the type and depth of foundations,
allowable bearing pressure and methods of construction.
10. Conclusion: - The main findings of investigations should be
clearly stated. It should be brief but should mention the salient
points.
Soil Exploration Report
![Page 126: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/126.jpg)
126
![Page 127: Site Investigation-for Section 3.pdf](https://reader031.vdocuments.site/reader031/viewer/2022011720/577c854b1a28abe054bc89a8/html5/thumbnails/127.jpg)
127
127
Why is a geotechnical subsurface exploration conducted?
What are the drilling methods that are commonly used in the
geotechnical subsurface exploration?
Under what soil conditions is mud rotary drilling used?
What are the types of samplers that are commonly used in
sampling soils?
What factors affect the SPT blow count (Nvalue)?
Soil Exploration Report