SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci- fi; - PET; - TOF; - calorimetry; - muon counters. ( * ) Pisa, Bari, Bologna, Messina, Perugia, Roma, Trento,Trieste, Udine INFN Aldo Penzo, INFN-Trieste HCAL Working group, CMS Upgrade Workshop FNAL, 19 Nov 2008 Trieste Ljublijana Legnaro Trento Udine

Upload: liliana-goodwin

Post on 29-Jan-2016

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

SIPMs: Italy Team Report

SiPMs development at FBK-irst started in 2005 as collaboration with INFN(*) for: - tracking with sci-fi; - PET; - TOF; - calorimetry; - muon counters.(*) Pisa, Bari, Bologna, Messina, Perugia, Roma, Trento,Trieste, Udine

INFN

Aldo Penzo, INFN-TriesteHCAL Working group, CMS Upgrade Workshop

FNAL, 19 Nov 2008

Trieste

Ljublijana

Legnaro

Trento Udine

Page 2: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Summary of multiple contributions

• http://www.ts.infn.it/eventi/TPDPPC_2008/

• Valter Bonvicini - The INFN R&D FACTOR • Claudio Piemonte - Development of SiPMs at FBK-irst • Arjan Heering - Requirements of SiPMs for CMS HCAL upgrades • Adam Para - Photodectors for dual readout calorimetry:

characterization and testing of SiPMT's • Aldo Penzo - Calorimetry R&D in FACTOR• Dalla Torre - Single photon detectors for Cherenkov Imaging • Valter Bonvicini - Preliminary results on SiPM irradiation tests• Giovanni Pauletta - SiPM characterization and applications; past

and future test activities at FNAL

Page 3: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

FACTOR Project

• Within FBK/irst - INFN agreement, a (3-year) project (FACTOR) aims at establishing SiPMs as choice devices for (dual) readout of (compensating) hadron calorimeters.

• FBK-IRST has long-standing collaboration with INFN in the fields of:

– Radiation-hard Si detectors (for SLHC)– use of oxigen-rich substrates:

• DOFZ substrates• Cz/MCz substrates (Magnetic Czochralski)• Epitaxial substrates

– use of p-type substrates

– Integration of Si detectors and (front-end) circuits on the same substrate

– 3D detectors

[Walter Bonvicini et al.: Messina, Roma, Trieste, Udine + FBK/irst]

Page 4: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

ITC-IRST (Trento)ITC (Now Fondazione Bruno Kessler ) – IRST is a public research and technology Institute, working since 1994 on the development and on the production od semiconductor devices for research and applications. It has a fully equipped Microfabrication Laboratory in which silicon devices are built.

- Ion Implanter- Furnaces- Litho (Mask Aligner )- Dry&Wet Etching- Sputtering &Evaporator- On line inspection- Dicing

Page 5: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Activity of SRD group

Development and production of Si radiation detectors.

Expertise covers the main aspects of the development:

TCAD simulationCAD design

Fabrication Device testing

Page 6: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Previous/current products

• Double-sided strip detectors:– Area:7.5x4.2cm2 – Orthogonal or inclined strips on 2 sides– DC- or AC-coupled– 700 + 800 “in spec” devices fabricated for AMS

and ALICE (2002-2005)

• Pixel detectors: – MEDIPIX (thick 1.5mm), 170x170/55x55 m2

– ALICE (200m) 400x50 m2

Page 7: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

3D Si Detectors

See S. Parker et al., NIM A395 (1997)

Short distance electrodes n e p: low depletion voltage short charge collection distance

column type ncolumn type p

Wafer surface

Substrate type n

extremely fast and radiation resistant

Ionising track

electroelectro

nsns

hole

hole ss

(carriers generated along the track are collected almost simoultaneously)

Electrodes are columns penetrating into the bulk

Page 8: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

3D Si Detector Project

FBK-irst and INFN-Trieste (L. Bosisio et al.)

• Collaboration for tests:– Ljubljana– UC Santa Cruz – INFN-Genova (ATLAS Pixel) – CERN (ALICE Pixel)

• Applications of this technology in other devices:– ‘throughout holes” transfer signals to back face (ex.SiPM) – planar detectors with “active edge’ (ex. imaging X-rays)

n+ diffusion

contact

metal

oxidehole

SEM pictures of 3D devices

Col. depth 180mCol. width 10m

Page 9: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

SiPM IRST technology

• Substrate: p-type epitaxial• 2) Very thin n+ layer • 3) Polysilicon quenching resistance• 4) Anti-reflective coating optimized for ~420nm

13

14

15

16

17

18

19

20

0 0.2 0.4 0.6 0.8 1 1.2 1.4

depth (um)

Do

pin

g c

on

c. (

10

^)

[1/c

m^

3]

0E+00

1E+05

2E+05

3E+05

4E+05

5E+05

6E+05

7E+05

E f

ield

(V

/cm

)

Doping

Field

n+ pShallow-Junction SiPM

p+ subst.

epi

n+

Drift regionHigh field region

p

guard region

[C. Piemonte:“A new Silicon Photomultiplier structure for blue light detection” NIMA 568 (2006) 224-232]

Page 10: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Configuration on Si wafer

First production run (2005) • square SiPMs with area: - 1x1mm2,2x2mm2

- 3x3mm2, 4x4mm2

- circular SiPMs- linear arrays of SiPMs: - 1x8, 1x16, 1x32- 4x4 matrix of SiPMs

Main blockWaferSecond production run

Page 11: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Characteristics of FBK-irst SiPMs

Fill factor: 40x40m2 => ~ 40% 50x50m2 => ~ 50% 100x100m2 => ~ 76%

1x1mm2 2x2mm2 3x3mm2 (3600 cells) 4x4mm2 (6400 cells)

Geometries:

Circular: diameter 1.2mm diameter 2.8mm

Page 12: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Tests performed at FBKTests performed at FBK

• I-V measurement

– fast test to verify functionality and uniformity of the properties

• Functional characterization in dark

– for a complete characterization of the output signal and noise properties (signal shape, gain, dark count, optical cross-talk, after-pulse)

• Photo-detection efficiency

C. Piemonte et al. “Characterization of the first prototypes of SiPM fabricated at ITC-irst” IEEE TNS, February 2007

Page 13: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Leakage current: mainly due to surface generation at the micro-diode periphery

Static characteristic (I-V)Static characteristic (I-V)

Matrix 4x4 1-9

1.E-11

1.E-10

1.E-09

1.E-08

1.E-07

1.E-06

1.E-05

0 5 10 15 20 25 30 35Vrev [V]

I [A

]

SiPM4 - W12

Breakdown voltage

Breakdown current: determined by dark events

Very useful fast test. Gives info about:- Device functionality- Breakdown voltage- (Dark rate)x(Gain) uniformity- Quenching resistance (from forward I-V)

Reverse I-V

Performed on several thousands ofdevices at wafer level

Page 14: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Dark signals are exactly equal to photo-generated signals functional measurements in dark give a complete picture of the SiPM functioning

Signal properties – NO amplifierSignal properties – NO amplifier

0.E+00

1.E-03

2.E-03

3.E-03

4.E-03

5.E-03

6.E-03

7.E-03

0.0E+00 1.0E-07 2.0E-07 3.0E-07 4.0E-07

Time (s)

Am

pli

tud

e (V

)

Thanks to the large gain it is possible to connect the SiPM directly to the scope

VBIAS

SiPM

50

DigitalScope

SiPM: 1x1mm2

Cell: 50x50m2

Page 15: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

15

0

100

200

300

400

500

600

700

800

0 20 40 60 80 100 120Charge (a.u.)

Co

un

ts

0.0E+00

5.0E+05

1.0E+06

1.5E+06

2.0E+06

2.5E+06

3.0E+06

3.5E+06

31 32 33 34 35 36

Bias voltage (V)

Ga

in

Pulse gen.

Laser

Pulse area= charge

histogram collection

SiPM

~ns

1p.e. 23

4

pedestal.

Excellent cell uniformity

Lineargain

Signal properties – NO amplifierSignal properties – NO amplifier

Page 16: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

s = singled = double pulsesa = after-pulse

VBIAS

SiPM

50

DigitalScope

Pulses at the scope.

Av100x

Signal properties – with amplifierSignal properties – with amplifier

A voltage amplifier allows an easier characterization,but attention must be paid when determining the gain

Page 17: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Microcell functionality measurementsMicrocell functionality measurements

measurements with RWTH, Aachen and Josef Stefan , Ljublijana

Page 18: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Pencil LED scan

Measurement of the microcells with 5m

Page 19: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Uniformity map

Page 20: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

4x4mm2

0.01

0.10

1.00

10.00

-1.0E-08 5.0E-08 1.1E-07 1.7E-07 2.3E-07Time (s)

Am

plit

ud

e (

a.u

.)

1mm2

T = -15C

T = -25C

Signal shape

1mm2 SiPM

0.E+00

1.E+06

2.E+06

3.E+06

4.E+06

5.E+06

6.E+06

7.E+06

28 29 30 31 32 33

Voltage (V)

Da

rk c

ou

nt (

Hz)

16 x Dark Count of 1mm2 SiPM

-15C -25C

0.E+00

1.E+06

2.E+06

3.E+06

28 29 30 31 32 33

Voltage (V)

Ga

in

-15C

-25CGain

Dark count

4x4mm2 SiPM - 50x50m2 cell

Page 21: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

4x4mm2 SiPM - 50x50m2 cell

Same conclusions as for the previous device:

• Excellent cell response uniformity over the entire device (6400 cells) Width of peaks dominated by electronic noise

-5.E-10 2.E-09 4.E-09 6.E-09 8.E-09

Charge (V ns)

28.6V

29.2V

29.6V

12 3

4

5

1

2

34 5 6

12

3

4 5 6 7

8

T=-25C Vbd=27.6VCharge spectra when illuminating the device with short light pulses

Page 22: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

1.0E+02

1.0E+03

1.0E+04

1.0E+05

1.0E+06

-0.70 -0.60 -0.50 -0.40 -0.30 -0.20 -0.10 0.00

Threshold (V)

Cou

nts

DC 28DC 28.5DC 29DC 29.5DC 30DC 30.5DC 31DC 32DC 33

• Each of the above curves represents the dark count rate as a function of the counting discriminator threshold.

• Different curves correspond to different bias voltages. Dark counts were also measured as a function of temperature.

Dark counts vs discrim. threshold

Page 23: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Photo-detection efficiency

Page 24: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

30

40

50

60

70

80

90

100

300 400 500 600 700 800Wavelength (nm)

QE

(%

)

0V

-2V

Simul

Simul ARC

0.00E+00

2.00E+00

4.00E+00

6.00E+00

8.00E+00

1.00E+01

1.20E+01

1.40E+01

1.60E+01

350 400 450 500 550 600 650 700 750 800

Wavelength (nm)

PD

E (

%)

36V

36.5V

37V

37.5V

38V

V=2V

2.5V

3.5V

3V

4V

QE vs Wavelength

long : low PDE becauselow QE

short : low PDE becauseavalanche triggered byholes

Measured on a diode

Reduced bysmall epi thickness

Reduced by ARC

Area efficiency ~ 20%

PDE=QE*Pt*Ae

QE=quantum eff.Pt=avalanche prob.Ae=area eff.

PD

E

350 400 450 500 550 600 650 700 750 800

Page 25: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Comparison of PDE

• From Arjan in Trieste, 3 June 2008

PDE at ~3 volt overvoltage

-5

0

5

10

15

20

25

30

35

300 350 400 450 500 550 600 650 700 750 800

Wavelength

(%)

FBK 5(Ti,34 V)

FBK 11(AU,35 V)

Ham (3x3mm,70V)

CPTA (2.1x2.1mm 36V)

CPTA (3x3mm 22V)

HB,HE,HO

HF

Page 26: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Activities at Trieste-Udine• The FACTOR collaboration is interested in the development of the

device and in its optimization for application to:

• Present application interests:– Calorimetry with fiber-based optical readout– Large – area scintillator – based muon counters– Scintillating fiber – based tracking– future space experiments for detection of UHECR– FEL studies and instrumentation– future large – area, ground – based x-ray telescopes

• Action Plan:– comparative studies for detailed understanding of device characteristics– Application tests– Optimization of properties as a function of application

Page 27: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

First year FACTOR • 2007: mainly dedicated to device characterization and test:

• Comparison of SiPM characteristics produced by different manufacturers;• Measurements of SiPM characteristics as a function of T;• Irradiation of the devices and study of radiation damage effects;• Tests with SiPMs coupled to wls fibers for scintillator read-out.• Energy and time resolution measurements;• Study of optimal packaging, electronics placement, etc.• At the moment, we are performing tests on SiPMs from 3 different• sources:• Forimtech (MRS):

– 1 mm2 in TO18 - P 560 nm - 556 µcells 43x43 µm2• Photonique (MRS):

– “GR sensitive” - 1 mm2 in TO18 - 556 µcells ~ 43x43 µm2– “Blue sensitive” - 1 mm2 in TO18 - 556 µcells ~ 43x43 µm2– “Blue sensitive” - 4.4 mm2 on PCB - 1748 µcells ~ 50x50 µm2– “Blue enhanced” – 9 mm2 in TO5 – 8100 µcells ~ 33x33 µm2

• IRST (polysilicon), 1 mm2 - P 420 nm (devices from 2nd and 3rd batch)– 625 µcells, 40x40 µm2

Page 28: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Fast Amplifier• Amplifier used for fast

characterization of SiPMs:• Agilent ABA-52563 3.5 GHz RFIC

Amplifier• (economic, compact, internally

50-Ω matched, gain ~ 20 dB)

Page 29: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Amplifier Characterization

• Temperature dependence:• Measurements performed with

the DUT in a climatic chamber (with humidity control)

• The amplifier was outside the chamber, connected via a special 18 GHz ft 50 cable.

• Timing characteristics can be studied

Page 30: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Test Setup at INFN Lab

Page 31: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Present Tasks • SiPM Development

– Comparative device characterization (ISRT, Hamamatsu, Formitech)

– Development (in collaboration with IRST)– Optimization of packaging & (fast!) preamplification

• Irradiation studies (so far on 24 SiPM's) – FBK-irst, Hamamatsu Photonique, Formitech– X-rays @ INFN Legnaro Labs (50 – 500 krad)– neutrons @ IJS reactor, Ljubljana (~4.8 x 101 0 n/cm 2 )

• Application Studies– Large area muon counters (FNAL)– Calorimetry with optical readout (FNAL/CERN/Frascati)– Scintillator-based fine-grained hodoscopes (CERN)

• Preliminary study of Scint. Strips viewed by IRST SiPM at the FNAL test beam (prototype of muon detector/tail catcher for ILC)

Page 32: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Test at Frascati

Electron beam with a Cherenkov calorimeter counting multiplicity

6 cm

6 cm

2.5 cm

Scint. TileSiPM

WLS fiber

Page 33: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Test beam at CERN

• Test beam at CERN (May/June 2008) with the MICE experiment: 8 extruded scintillator bars (1.5x1.9x19 cm3) with wls fibers, read out by SiPMs (IRST and Hamamatsu), all other bars of the MICE calorimeter read out by MAPMT.

• An ad hoc mechanical receptacle was realized to couple and align the fibers with the SiPMs and test them in a 2 GeV positron beam

• Frontend electronics: VA64TAP3.1 +LS64 by Gamma Medica-IDEAS; trigger signals sampled by an Altera with a 320 MHz clock

Page 34: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Mice detector

• A small fraction of the prototype fibers are readout with SiPM. The SiPM receptacle is visible to the right

Page 35: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

The SiPM response

• Correlation MAPMT vs SiPM amplitude

Pulse-height plot of the SiPM obtained selecting good events on the MAPM side

Page 36: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Radiation studies• Systematic campaign this year: study resistance to radiation

effects of SiPMs produced by different manufacturers– Objective: study both surface and bulk damage in the devices– Types of radiation used: X-rays (up to 50 keV) and neutrons– Measurement strategy: I-V characterization, dark count and gain

before and after irradiations, annealing studies– 24 devices from FBK-irst, Photonique (CPTA) and Hamamatsu

irradiated so far; further irradiations are foreseen in the next weeks

• X-rays: INFN National Laboratories of Legnaro (LNL), X-ray tube (W target), Vmax = 50 kV, dose rate measured with calibrated Si p-i-n diodes

• Neutrons: Nuclear Reactor of the Institute Josef Stefan of Ljubljana (Slo), max power ~ 250 kW, very high fluence achievable

X-rays @ INFN Legnaro Labs (50, 100 and 150 krad); X-rays @ INFN Legnaro Labs (300 and 500 krad); neutrons @ IJS reactor, Ljubljana (fluence ~ 4.8 x 1010 n/cm-2);

Page 37: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Irradiation studies (so far on 24 SiPM's) – X-rays @ INFN Legnaro Labs (50 – 500 krad)– neutrons @ IJS reactor, Ljubljana (~4.8 x 1010 n/cm2)– (spectrum ?)

– Very preliminarly:

– With 300 krad X-rays, HPK DC increase by 20 – 25– FBK by 4 - 5 – With 500 krad, HPK by 36-40, FBK by 6 - 8

– With 4.8 x 1010 n/cm2, HPK DC increase by 45-60, FBK by 15 - 20 . (See next page)

Page 38: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Other measurements and estimates

See: T. Matsumura (June 29, 2007) International Workshop on new photon-detectors (PD07)(Kobe University)

Neutron ≈ Proton

Proton ≈ 100 x X-ray

Page 39: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Triga 3 reactor JSL

Page 40: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Magnetic field resistance

• “Investigation of a Solid-state Photodetector”, NIM A 545:727-737 (2005).

• “Effects of a strong magnetic field on LED, extruded scintillator and MRS photodiode”, NIM A553: 438-447 (2005)

• (Vishnu V. Zutshi)

Page 41: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

SiPM for HF?• PMT fake signals in HF: show-stopper?

• SiPM useful but:

• Radiation hard?

• Small dimensions?

• Dinamic range?

• Consider matrix of 4x4 mm2 FBK SiPM– To cover 2.4 cm diameter PMT window

~130 GeV

up to few TeV!

Page 42: SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

SiPM matrix…

…if 1 SiPM costs ≤10$ …

… not out of question?