sign surveys north 2015
TRANSCRIPT
signsurveysnorth
CARPHONE WAREHOUSE - BIRKENHEAD SS1553
2174mm
2125mm
2124mm
2130mm
2125mm
2135mm
2125mm
2135mm
2178mm
2132mm
87mm SHORT
162.20
164.20
161.90
161.60
161.60
165.70
160.90
161.70
161.90
SECTION THROUGH FASCIA
TROUGH LIT FOLDED PANELS TO FACETTED TIMBER BACKGROUND
45mm
40mm
45mm
1040mm
50mm
signsurveysnorth
TOYOTA - LEEDS SS2274
1995mm
5250mm
89.7-89.9
89.3-89.6
17785mm
PROPOSED DEMISE LINE
START OF BLANK PANELS
TOYOTA
TOYOTA
HYUNDAI
180mm
NOTE - ALL DIMENSONS ARE FACE SIZES OF EXISTING CLADDINGREQUIRES BESPOKE 650mm HIGH BLANK GREEN PANELS TO MATCHPROPOSED HYUNDAI SIGN HEIGHT
*PM TO CONFIRM WITH HYUNDAI THAT THEY WILL BEALIGNING THE BOTTOM OF THE PANELS TO THE SAME POINT
89.5-89.6
89.5
134.1-134.6
10110mm
133.6-133.9
A
B
B
A
mm676
2
mm528
3
mm556
2
8220mm
2965mm
SECTION THROUGH EXISTING FASCIA A-A PROPOSED FASCIA A-A PROPOSED FASCIA B-B
2000mm
SECTION THROUGH EXISTING FASCIA B-B
B
B
B
B
605mm650mm
new blank panels629mm
27mm
CANOPYOBSTRUCTSBELOW
NOTE - PANEL WITH DOWNSTAND ONLY REQUIRED TOSECTION WITH CANOPY BELOW OVERALL LENGTH3825mm
downstand requiredto install new panels
top of panels to align throughwith rest of fascia - panel height tobe reduced to fit area above canopy& also take into account downstand
20mm50mm
signsurveysnorth
CITROEN - PRESTON SS1129
252mm
EXISTING TOTEM BASE DETAIL
EXISTING COMMERCIAL SIGN BASE DETAIL
NOTE - THE BASE AND STUDWORK HAS BEEN INSTALLED FOR THE COMMERCIAL VEHICLESSIGN HOWEVER ONE OF THE STUDS APPEARS TO BE DAMAGED AND SET AT AN ANGLE
792mm 252mm
200mm
mm691
mm037
mm791
mm791
mm091
202mm 2689mm 190mm
200mm
600mm600mm 2300mm
STUD DAMAGEDSET AT ANGLE
15mm dia
2687mm
22mm dia 22mm dia
252mm 792mm
1800mm
252mm
mm052
mm052
mm052
mm009
signsurveysnorth
TESCO - LIVERPOOL SS1575
SECTION THROUGH PROFILE A - A
*existing sign face dimensions
*canopy drops down in front of thesign obscuring some of the top section
*canopy drops down in front of thesign obscuring some of the top section
SECTION THROUGH PROFILE B - B
Note - fit new sign panelsover existing backtray
roller shutter
*sign fitted at top by hooking over rails
*sign fitted at top by hooking over rails
1210mm
1070mm
1070mm
80mm 22mm
30mm
975mm
156mm
220mm
80mm
60mm
22mm
30mm
A
A
B
B
2980mm 3597mm*11mm short
2605mm 3588mm 2980mm 3875mm12mmshort
12mmshort
975mm 570mm
200mm840mm
145mm
cladding panels1160
360
1130
715
800mm x 400mm standard internallyilluminated projecting sign currently reads ‘24 hr cash’ (in fair condition)
3020mm
existing 320mm externally applied vinyls existing 320mm external vinyls
2960mm 2960mm
1175
*face fixed camera
524mm
790mm
524mm
mm0002
signsurveysnorth
BARBURRITO - LEEDS SS1198
Folded tray panels withpushed though acrylic lettering
Branded seating areaMenu display unit
Externally appliedcontravision graphic
Double sided projecting signLooks to be clear acrylic face panels with vinylbacked up with white opal & black outer edges
Folded tray panels withpushed though acrylic lettering(recessed over doorway)Full backtray to rear
Deep acrylic box with bespokelighting and poster frame
signsurveysnorth
SHELL PFS - BLACKPOOL SS1284
PUMP 9/10DIESEL ONLY
1
2
3
4
5
6
7
8 8
9
10
CO
LLIN
GW
OO
D A
VE
NU
E
CAUNCE STREET
ACCESS ISSUECANOPY CLOSETO SITE BOUNDARY
ACCESS ISSUECANOPY PROJECTSABOVE SHOP ROOF
CAR WASH
JET WASH
CANOPY
SHOP
11
signsurveysnorth
KFC - GLASGOW SS1686
FLEXFACE BOX15740mm x 785mm
ALL BOXES HAVE BLACK CLIP FIXINGS
FLE
XFA
CE
BO
X84
60m
m x
785
mm
FLE
XFA
CE
BO
X59
14m
m x
785
mm
FLEXFACE BOX6770mm x 785mm
NOTE - ACCESS ISSUE TO THIS ELEVATION DUE TO HEAVY SLOPING GROUND & SHRUBBERYSMALL CHERRY PICKER REQUIRED TO WORK FROM PAVEMENT TO ACCESS REAR OF POST SIGN & ALSO ELEVATION ‘B’
FLE
XFA
CE
BO
X62
95m
m x
785
mm
FLE
XFA
CE
BO
X25
05m
m x
175
5mm
FLEXFACE BOX2505mm x 1755mm
FLEXFACE BOX5737mm x 780mm
NOTE - SEPARATE BOXES WITH MITRED JOINT& VELCRO FIXED CORNER TRIMS (MOSTLY MISSING)SEE CLOSE UP PHOTOS
NOTE - ELEVATION G & D END OF BOX SITS ON TOP OF CAPPINGUNCLEAR HOW FLAPS WILL OPEN?
A
B
C
DE
F
G
H
A B C DE FG H
3400mm 3660mm
2600mm
1100mm
*HEAVY SLOPE & SHRUBBERY SEE SITE PHOTOS
signsurveysnorth
TESCO - MANCHESTER SS1542
DENOTES TRAFFIC DIRECTION
DENOTES PHOTO DIRECTION
POST MOUNTEDDIRECTIONAL SIGN2950mm x 990mmPHOTOS 11-18
D/S POST MOUNTEDDIRECTIONAL SIGN1250mm x 1250mm - 60 RadPHOTOS 34-39Photos 81-86 (exit route)
D/S POST MOUNTEDDIRECTIONAL SIGN1250mm x 1250mm - 60 RadPHOTOS 21-31
D/S POST MOUNTEDDIRECTIONAL SIGN1250mm x 1250mm - 60 Rad(REPLICATES 66/67)
D/S POST MOUNTEDDIRECTIONAL SIGN1250mm x 1250mm - 60 RadPHOTOS 66-67
D/S POST MOUNTEDDIRECTIONAL SIGN1250mm x 1250mm - 60 RadPHOTOS 70-76 OPTION TO ADD C&C FOR EXIT ROUTE? OPTION TO ADD C&C FOR EXIT ROUTE?
GANTRY 1
GANTRY 1POSITION
315mm
1855mm
1800mm
1390mm
15
20
24
33 38 51
53
57
59
55
62
64
667174
79
84
86
NOTE SIGN OBSCURRED BY TREELINESUGGEST NEW POSITION ON LEFT OF ROADD/S POST MOUNTEDDIRECTIONAL SIGN1250mm x 1250mm - 60 RadPHOTOS 40-49
signsurveysnorth
MAZDA - LEICESTER SS1559
SECTION THROUGH FASCIA
1905mm
50mm
195mm
2585mm
3272mm 3273mm 2388mm 1800mm 2390mm 3315mm
1675mm
NOTE - ANGLE CAN BE WORKED OUT FROM WIDTHS & HEIGHTS OF GLAZING PROVIDED
FRONT ELEVATION NOTE - THERE IS NO SECONDARY SUPPORT STEELWORK INSIDE THE FACE CAPPING
THE EXISTING STRUCTURE WILL NOT SUPPORT A SUSPENDED SIGN SO THIS MAY REQUIRE ADDITIONAL WORKS BY OTHERS - PM TO CONFIRM OPTIONS
1440mm 1270mm
1142mm 970mm
50mm 50mm 50mm 50mm 50mm 50mm 50mm
195mm
175mm
NOTE - STEELWORK PREVENTS ANY CLEAR ACCESS TO THE REAR OF THE CLADDING
210mm
20mm
50mm
128mm
145mm
220mm 137mm
140mm175mm
170mm
signsurveysnorth
FORD CAT SCAN SURVEY - CASTLETON SS1360
NOTE - DOORS OPEN INWARDS & OUTWARDSHOWEVER THE SLOPING GROUND MEANS THAT IT WOULD NOT SIT UNDER THE FEATURE CROSSBAR
SUGGEST FOLDED ANGLE ‘STOPPER’ AS ABOVE ATPOLAR FORD STOCKPORT SO THE DOOR WILL ONLYOPEN INWARDS*ALSO TEXT TO WINDOW ‘PUSH/PULL’
NOTE - NOTE SUITABLE FOR SIZE 2 UNLESS DOOR ISSUE IS ADDRESSED
PLAN VIEW
*DENOTES LINE, STRENGTH & DEPTH OF CAT SCAN READINGSWHERE APPLICABLE
001 (READINGS AT 33 KHzwith generator on low setting)
022 150 DEPTH 0.75
*ASG PM TO ANALYSE CAT SCAN READINGS & ASSESS SUITABILITY FOR PROPOSED GROUNDWORKS
2210mm
35mm 30mm45mm 45mm
475mm
BLOCKPAVING
TARMAC
1420mm 1420mm
ALIGN TEXT PANEL LEFT
1830mm
SUGGEST STOPPER SO DOORS ONLY OPEN INWARDS
SUGGEST STOPPER SO DOORS ONLY OPEN INWARDS
2150mm
105mm152mm
1210mm
015 050033
033
028016
014 016
019
020
DEPTH <.3
DEPTH <.3
signsurveysnorth
SAFESTORE AUDIT & MAINTENANCE - PRESTON SS1300
FRONT ELEVATION - DIBOND PANELS x2- RUSTED FIXINGS- VANDALISM TO ONE SIDE PAINTED OUT - SEE PHOTOS- CORROSION TO POSTS - SEE PHOTOS
RECEPTION - BOX SIGN WITH OPAL PANELS/VINYL- REQUIRES CLEANING- MAY REQUIRE RE-TUBING- PAINT BUBBLING TO TRIM EDGES - SEE PHOTOS
FRONT ELEVATION - MAIN SIGNAGE ABOVE OFFICES - FLEX FACE SKIN IN VERY POOR REPAIR - FADED- SUGGEST REPLACEMENT SKIN- MAY REQUIRE RE-TUBING 3375mm TO FLAT ROOF LEVEL
RIGHT RETURN ELEVATION LEFT END - 2470mm TO U/S- FLEX FACE SKIN IN VERY POOR REPAIR - FADED- SUGGEST REPLACEMENT SKIN- MAY REQUIRE RE-TUBING- PAINT BUBBLING/PEELING TO BOX EDGES - SEE PHOTOS
FRONT ELEVATION STEP RETURN - FLEX FACE SKIN IN VERY POOR REPAIR - FADED- SUGGEST REPLACEMENT SKIN- MAY REQUIRE RE-TUBING
RIGHT RETURN ELEVATION - RIGHT END- FLEX FACE SKINS (3OFF) IN VERY POOR REPAIR - FADED- SUGGEST REPLACEMENT SKIN- MAY REQUIRE RE-TUBING
REAR ELEVATION - LEFT END- FLEX FACE BOX SIGN (THIS IS NOT IN AS POOR CONDITION AS THE OTHERS)- REQUIRES CLEANING- MAY REQUIRE RE-TUBING
REAR ELEVATION - NON ILLUMIANTED TRAY PANELS - LOOKS OK MAY REQUIRE MINOR CLEANING - 5200mm TO UNDERSIDE
AB
D
E
F
GH
C
A B
C D
E F G H
signsurveysnorth
jamie livesey
07403 414 609
www.signsurveysnorth.co.uk
www.thecreativeartcompany.co.uk
sign surveys north
the creative art company studio
fourteen roseberry road
ashton in makerfield
wigan
greater manchester
wn4 9tb