Sewer Infiltration MonitoringBackground

Widespread seasonal problem for many water companies

‘Unaccounted for Water’ typically caused by groundwaterentering the sewer through aged / defective pipework

Can result in internal & external flooding and pollution

Increased energy costs and wear at Sewage Pumping Stations

Increased vehicle / tanker movements(24/7 in some catchments)

Unhappy customers & stakeholders MP’s, LA’s, EA etc.

Page 3: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringBackground

Thames Water experienced wide scale infiltration eventsduring the winter of 2012/13 and 2013/14

Ongoing commitment to undertake investigations andinvestment in catchments at greatest risk

Investigations include flow monitoring, catchment &groundwater modelling, PS analysis etc.

Existing site investigation techniques – lift & look surveys,CCTV surveys, impermeable area surveys, stoppering etc.

Innovation considered alternative investigation techniques,both linked to temperature monitoring

Page 4: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS

Distributed Temperature Sensing (DTS)

Fibre-optic cable installed in a sewer with laser light pulsedalong the length

Temperature measurement recorded at 2m intervals everyminute.

Temperature differences identify inflows to sewer

Service provided Royal HaskoningDHV with site contractor

manhole manhole

sewer pipe

laser/computerinstrument

fiber-opticcable

container

external power supply

manhole manhole

sewer pipe

laser/computerinstrument

fiber-opticcable battery pack

Page 5: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS Investigations

Hambleden1674m cable

Monitoring Started 8th October 2014

Monitoring Ended 11th November 2014

Cuxham1151m cable

Monitoring Started 16th December 2014

Monitoring Ended 16th February 2015

Page 6: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS – Hambleden Cable Installation

Page 7: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS – Hambleden Cable Installation

Page 8: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS Example of Results

Page 9: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS Example of Results

Page 10: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS Example of Results

Page 11: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS Example of Results

Page 12: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS – Pump run times

Page 13: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringDTS Results

Trial demonstrated the potential of the system andprovided lots of data

Timing of deployment critical to capture infiltrationevent

Deployment required just prior to an eventBut, this is the unknown..

Technique also required jetting & CCTV

Some operational problems – ragging

Costly

Page 14: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Temperature measurement is used to optimise sewagetreatment processes

Considered option to identify infiltration into seweragenetworks?

Reduced temperature could indicate infiltration

Low cost equipment – around £100 per loggerSealed units – wireless data reader

Trial undertaken within a catchment with previoushistory of infiltration: Fencott & Murcott

Trial started September 2013

SLI51-KIT - USB-5Temperature Data Loggers

Page 15: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Comparable recordings from each logger

10

12

14

16

18

20

22

05/02/2015 07/02/2015 09/02/2015 11/02/2015

Deg

rees

C

Date

Temperature Logger Comparison Test

1

2

3

4

5

Page 16: Sewer Infiltration Monitoring

1

4

3

2

5

Sewer Infiltration MonitoringTemperature Loggers

Page 17: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Page 18: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Page 19: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Very good diurnal pattern recorded

Page 20: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Merton

Page 21: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

All sites - seasonal pattern over nearly 2 years

Page 22: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Infiltration Event Captured 2013 – 2014

Page 23: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Event with rainfall

Page 24: Sewer Infiltration Monitoring

1

4

3

2

5

Sewer Infiltration MonitoringTemperature Loggers

Page 25: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Pump run times

Page 26: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Pump run times

Page 27: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringTemperature Loggers

Other catchments – Ramsdell

Page 28: Sewer Infiltration Monitoring

Sewer Infiltration MonitoringSummary

Temperature loggers have provided good results todate

Durable hardware – survived in the sewers

Potential to use in the network to target sources ofinfiltration or unaccounted for water

Cost effective tool for long term measurement ofcatchment performance

No confined space access needed