service proportional regulators

40
Pneumatic Division Richland, Michigan USA www.parker.com/pneumatics PROPORTIONAL REGULATOR Bulletin Number Bulletin Description 407659 –––– P3P-R Installation Instructions 2R210 Rev. 2 P3HP Proportional Regulator V630CP Rev. 4 PAR-15 Installation V635P Rev. 1 PAR-15 Level “A” to “B” Solenoid Conversion V633P –––– PAR-15 Repair Tool V632P –––– PAR-15 Replacement Operators V631P –––– PAR-15 Service V634BP Rev. 2 PAR-15 with TE Solenoids Service Safety Guide –––– PDN Safety Guide

Upload: ricardo-gomes

Post on 23-May-2017

234 views

Category:

Documents


1 download

TRANSCRIPT

Pneumatic DivisionRichland, Michigan USAwww.parker.com/pneumatics

PROPORTIONAL REGULATOR Bulletin Number Bulletin Description

407659 –––– P3P-R Installation Instructions

2R210 Rev. 2 P3HP Proportional Regulator

V630CP Rev. 4 PAR-15 Installation

V635P Rev. 1 PAR-15 Level “A” to “B” Solenoid Conversion

V633P –––– PAR-15 Repair Tool

V632P –––– PAR-15 Replacement Operators

V631P –––– PAR-15 Service

V634BP Rev. 2 PAR-15 with TE Solenoids Service

Safety Guide –––– PDN Safety Guide

Pneumatic DivisionRichland, Michigan 49083269-629-5000

IntroductionFollow these instructions when installing, operating, or servicing the product.

Technical InformationThese products are intended for use in general purpose compressed air systems only.

PneumaticsWorking Media: Compressed air or inert gasses, filtered to 40µ.

Operating Pressure: Max. Operating Pressure ...... 2 bar unit ............. 3 bar (43.5 PSI) 10 bar unit ...... 10.5 bar (152 PSI)

Min. Operating Pressure .......... P2 Pressure + 0.5 bar (7.3 PSI)

Pressure Control Range: Available in two pressure ranges, 0-2 bar (0-29 PSI) or 0-10 bar (0-145 PSI). Pressure range can be changed through the software at all times. (parameter 19)

Temperature Range: .....................32°F to 122°F (0°C to 50°C)

Weight: ............................................................................ 10 oz.

Air Consumption: No consumption in stable regulated situation.

Display: The regulator is provided with a digital display, indicating the output pressure, either in PSI or bar. The factory setting is

as indicated on the label, can be changed through the software at all times (parameter 14).

Mounting Position: Preferably vertical, with the cable gland on top.

ElectronicsSupply Voltage: ................................................24 VDC +/- 10%

Power Consumption: ....................................................... 1.1 W

Current Consumption: .................... Max. 200 mA with no load

Control Signals: The electronic pressure regulator can be externally controlled through an analog control signal of 0-10 V, adjustable to 4-20 mA via parameter 4.

Connections: .............................. Central M12 connector 4-pole

The electrical connections are as follows:

Dead Band: The dead band is preset at 1.3% F.S.*, adjustable via parameter 13.

Accuracy: .............................................Linearity: = < 0.3% F.S.*

Proportional Band: The proportional band is preset at 10% F.S.*

Fail-safe Operation: After interrupting the power supply voltage, the present output pressure is maintained at approximately the same level. After switching the power supply on again, the pressure can be adjusted immediately by giving a new control signal.

Full Exhaust: Complete exhaust of the regulator is defined as P2 ≤ 1% F.S.*

Degree of Protection: .........................................................IP65

3

2

1

4

* Full Scale

Installation & Service Instructions 2R21040mm & 60mm Proportional Regulator

ISSUED: September, 2008Supersedes: May, 2005Doc. # 2R210, EN #080690, Rev 2

WARNINGTo avoid unpredictable system behavior that can cause personal injury and property damage:• Disconnect electrical supply (when necessary) before installation,

servicing, or conversion.• Disconnectairsupplyanddepressurizeallairlinesconnectedtothis

product before installation, servicing, or conversion.• Operatewithin themanufacturer’sspecifiedpressure, temperature,

and other conditions listed in these instructions.• Medium must be moisture-free if ambient temperature is below

freezing.• Serviceaccordingtoprocedureslistedintheseinstructions.• Installation, service, and conversion of these products must be

performed by knowledgeable personnel who understand how pneumatic products are to be applied.

• Afterinstallation,servicing,orconversion,airandelectricalsupplies(when necessary) should be connected and the product tested forproper function and leakage. If audible leakage is present, or the product does not operate properly, do not put into use.

• Warningsandspecificationsontheproductshouldnotbecoveredbypaint, etc. If masking is not possible, contact your local representative for replacement labels.

!

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure and review the information concerning the product or systems in the current product catalog. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met.The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

WARNINGProduct rupture can cause serious injury.Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

!

Safety Guide

For more complete information on recommended application guidelines, see the Safety Guide section of Pneumatic Division catalogs or you can download the Pneumatic Division Safety Guide at: www.parker.com/safety

Pin No. Function Description Color

1 24 V Supply Brown

20 to 10 V or 4 to 20mA

Control Signal Ri = 100k W White

3 0 V (GND) Supply Blue

4 24 V Alarm Output Signal Black

40mm & 60mm Proportional Regulator 2R210

Installation1. Place muffler in Port 32. Connect the device to the Air Supply Port 1 and 2.3. Connect Female M12 Connector on the Male Connector of

the device.4. Apply 24V = (10 second time delay for initialization of

unit).5. Air Supply to Port 1.6. Give desired Set Point Signal.7. Secondary Pressure will now be displayed.

How to Change ParametersPressing the Accept key for 3 to 6 seconds, will activate parameter change mode. The user can then select the parameters by pressing up or down key (display will show Pxx). When parameter number is correct, pressing accept again will enter parameter number (display will show parameter value).

2

Back to Factory SettingAfter start up. (Power is on)

Parameter 0 = 3

Entering this value in parameter 0 will store the calibrated factory data into the working parameters. (Default calibration data is used)

Parameter Number 0 – Reset Back to Factory Settings Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal Flashing Decimal Flashing

Description Accesses changeable parameters.

Accesses parameter no. 0.

Displays current parameter value.

Edits parameter. 3 = standard

factory settings. If other than 3, use

Up or Down Arrow and accept 3

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

Set Control SignalThe unit is factory set for 0-10 V control signal. If 4-20 mA control signal is required, change parameter 4.

Parameter Number 4 – Set Control Signal in Volts or Milliamps Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal Flashing Decimal Flashing

DescriptionAccesses

changeable parameters.

Accesses parameter no. 4.

Displays current parameter value.

1 = V, 0 = mA Edits parameter.

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

Pressing the up or down key will change the parameter itself (display will flash indicating parameter editing mode). Pressing the accept key will accept the new parameter value (all digits will flash while being accepted). After releasing all keys, the next parameter number will be presented on the display (you may step to the next parameter). When no key is pressed, after 3 seconds the display will show the actual output pressure.Only parameter numbers 0, 4, 9, 14, 18, 19, 20, 12, 13, and 21 are accessible to edit. All other parameters are fixed.Manual ModeWhen keys DOWN and UP are pressed during startup, (connecting to the 24 V power supply) manual mode is activated. This means that the user is able to in/decrease the output pressure of the regulator, by pressing the UP or DOWN key. During this action the display will blink, indicating that the manual mode is activated.

40mm & 60mm Proportional Regulator 2R210

3

Parameter Number 6 – Set Output Signal Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing DecimalFlashing Decimal (Value 0, 1 or 2) Flashing

Description Accesses changeable parameters.

Accesses parameter no. 6.

Displays current parameter value.

1 = m factory default for P3H with

analog options

Edits parameter.0 = digital

(NPN or PNP) 1 = analog 0..10V

2 = analog 4..20 mA

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

Parameter Number 8 – Adjust Span Analog Output Signal Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads Flashing Decimal

(For 2 bar versions value = 92)

Flashing Decimal (Value between

0 and 130) Flashing

Description Accesses changeable parameters.

Accesses parameter no. 8.

Displays current parameter value. Edits parameter.

Accepts and saves new parameter

setting and implements the new analog signal span.

Sequences to next parameter.

or or

Adjust Digital DisplayIf necessary, adjustments can be made to the digital display when using an external pressure sensor.

ParameterNumber9–AdjustDigitalDisplayValue(PressureCalibration) Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal Flashing Decimal Flashing

DescriptionAccesses

changeable parameters.

Accesses parameter no. 9.

Displays current digital display

Use up or down arrows and accept

to adjust the display value if

using an external pressure sensor.

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

40mm & 60mm Proportional Regulator 2R210

4

Set Pressure ScaleUnits with NPT port threads are supplied with a factory set PSI pressure scale. Use parameter 14 to change scale to bar.

Parameter Number 14 – Set Pressure Scale in PSI or bar Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal Flashing Decimal Flashing

DescriptionAccesses

changeable parameters.

Accesses parameter no. 14.

Displays current parameter value.1 = PSI, 0 = bar Edits parameter.

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

Preset Minimum PressureIf there is a need for a pre-set minimum pressure, use parameter 18. (Note: preset pressure is affected by % P19.)

Parameter Number 18 – Set Minimum Preset Pressure Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Flashing Decimal (value between

0 and 200) Flashing

Description Accesses changeable parameters.

Accesses parameter no.

18.

Displays current parameter value. Incremental value is:

2 bar unit: x 2 mbar x % P19

10 bar unit: x 10 mbar x % P19 Edits parameter.

Accepts and saves new parameter

setting.Sequences to

next parameter.

or or

Set Pressure CorrectionPressure correction allows the user to set a maximum pressure as a percentage of secondary pressure F.S.Example: If F.S. is 10 bar, set parameter 19 to 50 for maximum preset pressure of 5 bar.Pressure correction also affects the minimum preset pressure in parameter 18.Example: If F.S. is 10 bar and parameter 18 is set to a value of 100 (1 bar), and parameter 19 is set to 50%, then the actual minimum preset pressure seen is 0.5 bar.

Parameter Number 19 – Set Maximum Preset Pressure Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Flashing Decimal (value between

0 and 100) Flashing

Description Accesses changeable parameters.

Accesses parameter no. 19.

Displays current parameter value.

Incremental value is: % of F.S. Edits parameter.

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

Parameter Number 20 – Set Behavior Control Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Flashing Decimal (value between 0

and 5) Flashing

Description

Accesses changeable parameters.

Accesses parameter

no. 20.Displays current parameter value.

Edits parameter 0 = custom set*

1 = fastest (narrow proportional band)

2 = fast, 3 = normal,

4 = slow, 5 = slowest

(proportional band is broad)

Accepts and saves new parameter

setting.Sequences to next

parameter.

40mm & 60mm Proportional Regulator 2R210

5

Behavior ControlThe regulation speed of the pressure regulator can be modified by means of one parameter. (P 20)The value in this parameter has a range from 0-5. A higher value indicates slower regulation speed, but will be more stable.

* When the value 0 is entered, you are able to create your own custom settings true parameters 12, 13 and 21.

or or

Set Proportional BandProportional band is used for setting the reaction sensitivity of the regulator. The displayed value is X 10 mbar and has a range between 50 (0.5 bar) and 250 (2.5 bar).

Fine Settings

ParameterNumber12–SetProportionalBand(P20MustbeSetto0)Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Flashing Decimal (value between

50 and 250) Flashing

Description Accesses changeable parameters.

Accesses parameter no. 12.

Displays current parameter value.

Incremental value is:

x 10 mbar Edits parameter.

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

Parameter Number 39 – Displays Current Software Version Step 1 2 3

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Description Accesses changeable parameters.

Accesses parameter no. 39.

Displays current parameter value.XXX = current

software version

40mm & 60mm Proportional Regulator 2R210

6

Set DeadbandDeadband is the minimum limit of accuracy at which the regulator is set for normal operation. The displayed value is X 10 mbar and has a range between 4 (40 mbar) and 40 (400 mbar).

ParameterNumber13–SetDeadband(P20MustbeSetto0)Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Flashing Decimal (value between

4 and 40) Flashing

Description Accesses changeable parameters.

Accesses parameter no. 13.

Displays current parameter value.

Incremental value is

x 10 mbar Edits parameter.

Accepts and saves new parameter

setting.Sequences to next

parameter.

or or

or

ParameterNumber21–SetProportionalEffect(P20MustbeSetto0)Step 1 2 3 4 5

Press

3-6 seconds

Until Display Reads

Flashing Decimal

Flashing Decimal (value between

5 and 100) Flashing

Description Accesses changeable parameters.

Accesses parameter no. 21.

Displays current parameter value.

Edits parameter. 5 = fastest regulation

100 = slowest regulation.

Accepts and saves new parameter

setting.Sequences to next

parameter.

Proportional EffectSets the speed at which the regulator adjusts either filling or exhausting. The displayed value has a range between 5 (fastest regulation) and 100 (slowest regulation).

or or

40mm & 60mm Proportional Regulator 2R210

7

Problem Possible Reason Solution

Display will not light up No 24 volts power supply Check if the wiring is connected according to the schematic wiring diagram

Unit will not, or not correctly respond to given setpoint

Wrong current applied ( I.e. Volt instead of mA or mA instead of Volt

Change setpoint current or re configure the setpoint current through the software by changing parameter 4

Check wiring if the setpoint signal lead is connected to the right pin within the male M12 connector ( should be pin 2)

Setpoint signal is not stable enough Stabilize setpoint signal input

Display shows NoP. Unit detects that required output pressure is higher than the supplied pressure

Adjust the inlet pressure to a higher value, preferably 0,5 bar higher than requested output pressure

Give lower setpoint value which corresponds to a output pressure lower than the inlet pressure

No inlet pressure at all Connect port 1 to the supply pressure

Unit behavior is not considered normal Faulty settings made in the parameters Reset the unit to factory settings by using the green key function under parameter 0

Desired pressure can not be reached Setpoint value to low

Pre-set pressure limit has been changed to a lower max. outlet pressure

Increase setpoint value

Change max. outlet pressure back to required pressure by changing parameter 19

Supply pressure is to low Increase supply pressure

Secondary side stays pressurized Setpoint value is higher than 0,1 Volt

Pre-set pressure has been enabled to a certain pressure

Lower your setpoint value, preferably to 0 Volts

Reset parameter 18 to 0

Display shows unrealistic value Display maybe configured in the wrong value ( bar instead of psi)

Check through parameter 14, if the display value is set on either psi or bar, if necessary change it to the required setting

Unit response time too slow or too quick Volume behind the unit is either too big or too small

Adjust the regulating speed of the unit through parameter 20

Unit gives too much overshoot Relation between volume and response me is out of balance

Adjust response time to a higher value through parameter 20, to achieve more accurate behavior

Unit is adjusting/regulating constantly Air leakage in the system behind the unit

Constant changing volume behind the unit

“Deadband “area is set too small

Resolve leakage

Unit needs to regulate to keep required pres-sure at the same level

Try to minimize the volume changes

Enlarge deadband setting through parameter 13 in the software ( parameter 20 has to be set to 0 before changing parameter 13)

Can not enter software through touchpad Unit is currently working/processing Make sure that the unit is in steady state while activating the software

Activating time is too short Hold the accept button for at least 3 seconds

Display indicates ‘OL’ Wiring not according to diagram (24 volt connected on the setpoint connection pin)

Rewire so that on the setpoint connection pin will be either 0-10v or 4-20mA

Wrong setpoint value given in relation to programmed setpoint value acceptance

Change over setpoint value to either V or mA or Reprogram the unit to the correct setpoint value via parameter 4

Any other problem Please consult factory

40mm & 60mm Proportional Regulator 2R210

Dimensions

Dimensionsareinmm(Inches)

8

0.55(14)

4.49(114)

1.85(47)

1.18(30)

1/4 1/4

1/4

Ø 0.87(22)

0.85(21.5)

0.08(2)

0.35(9)

0.83(21)

0.83(21)

Ø 0.22(5.5)

4 Pin M12 Connector

0.53(13.5)

0.35(9)

2.19(55.5)

80°

4.49(114)

1.85(47)

1/4

1/4

1/4

0.59(15)

1.65(42)

Ø 0.87(22)

0.83(21)

40mm Bottom Exhaust Version

1.83(46.6)

1/4(3x)

1.65(42)

21(0.83)

0.09(2.3)

DIN-RailClamp

4.49(114)

Ø 0.87(22)

0.35(9)

Dimensionsareinmm(Inches)

Foot Bracket

DIN Rail Bracket

4 Pin M12 Connector

0.56(14.3)

6.62(168.1)

2.46(62.6)

4.12(104.6)

2.50(63.5)

1.18(30)

2.95(75)

1.48(37.5)

1/2” Port

1.18(30)

2.36(60)

60mm Bottom Exhaust Version

.59(15)

.59(15)

.59(15)

.98(25)

1.18(30)1.42(36)

1.77(45)

L Bracket

.47(12)

2.20(56)

1.02(26)

2.05(52)

1.57(40)

2.05(52)

3.31(84)3.94(100)

Ø .28 (7)

4 Holes

Foot Bracket

Bulletin 407659 Part No 494689

Installation & SettingInstructions

Rev. 0 Page 1/8Date 13.03.1999

P3P-R Pressure Regulator

BSP Series : P3P – RP11C100GP3P – RP11C106DP3P – RP11C107DP3P – RP11C400GP3P – RP11C406DP3P – RP12T100GP3P – RP12T106DP3P – RP12T107DP3P – RP12T400GP3P – RP12T406D

P3P – RJ12C100GP3P – RJ12C106DP3P – RJ12C107DP3P – RJ12C400GP3P – RJ12C406DP3P – RJ14C100GP3P – RJ14C106DP3P – RJ14C107DP3P – RJ14C400GP3P – RJ14C406D

NPT Series : P3P – RP91C100GP3P – RP91C106DP3P – RP91C107DP3P – RP91C400GP3P – RP91C406DP3P – RP92T100GP3P – RP92T106DP3P – RP92T107DP3P – RP92T400GP3P – RP92T406D

P3P – RJ92C100GP3P – RJ92C106DP3P – RJ92C107DP3P – RJ92C400GP3P – RJ92C406DP3P – RJ94C100GP3P – RJ94C106DP3P – RJ94C107DP3P – RJ94C400GP3P – RJ94C406D

494689 P3P-R Pressure Regulator

2

CONNECTION DIAGRAMS

P3P-R…..0G P3P-R…..6D

-

Control signal 0...10V or 4...20mA

Supply voltage 24V

Gnd

Gnd

CTRL

24V+

-

+

1

5

2

4

6+

+-

-Output 0 ...10V

Control signal 0...10V or 4...20mA

Supply voltage 24V

Output 4...20mA

P3P-R…..7D1

5

2

4

6+

+-

-Output 0 ...10V

Control signal 0...10V

Supply voltage 24V

Output alarm 0/24V

1 . POTENTIOMETER P1 2 . POTENTIOMETER P2Set up of calibration Set up of zero offset

P max

(10 bar)

P min.0.2 bar

min. 0.1V

min. 4.3 mA

max. 10 V

max. 20 mA

Controlsignal

min. 1 bar/10V

max.5 V/10 bar

P max

(10 bar)

P min.0.2 bar

min. 0.1V

min. 4.3 mA

max. 10 V

max. 20 mA

Controlsignal

3 bar

3V8.8 mA

P max

(7 bar)

P min.0.2 bar

min. 0.1V

min. 4.3 mA

max. 10 V

max. 20 mA

Controlsignal

min. 1 bar/10V

max.3.5 V/7 bar

P max

(7 bar)

P min.0.2 bar

min. 0.1V

min. 4.3 mA

max. 10 V

max. 20 mA

Controlsignal

3 bar

3V

8.8 mA

max.

min.

Min., max., calibration

Standard factory set up

Zero shifting, min., max.

Rotation of potentiometers

Remark : All special calibrations, even the analog output signal calibration, have to be asked and made by the factory.

P3P-R…C….

P3P-R…T…

494689 P3P-R Pressure Regulator

3

POSITION OF POTENTIOMETERS

P3P-R…..0G

P1P2P3P4P5

24V

GND

GND

CTRL

T1/T HOLD

IN

HYST OFFS CAL

P3P-R…..6D P3P-R…..7D

IN

24V

CTRL

GND

GND

OUTU

OUTIA

P1P2P3P4P5

T1/T HOLD HYST OFFS CAL

IN

24V

CTRL

GND

GND

OUTU

OUTIA

P1P2P3P4P5

T1/T HOLD HYST OFFS CAL

P8

P6

P7

P9

P6

P7

BASE PRINTED BOARD ASSEMBLY

BASE PRINTED BOARD ASSEMBLY

OUTPUT SIGNAL MODULE

494689 P3P-R Pressure Regulator

4

PORT CONNECTIONS RECOMMENDED MOUNTING POSITIONUpright, electronic on the top

PA

R

Inlet pressure max. 12 bar.Inlet pressure must beat least 1 bar higherthan regulated pressure.

Outlet portRegulated pressure.

Exhaust

ELECTRICAL CONNECTIONS SPARE PARTS KITS

P1P2P3P4P5

24V

GND

GND

CTRL

T1/T HOLD

IN

HYST OFFS CAL

24V

GND

GND

CTRL

1 2

3

45

6

6 P +

POWER SUPPLY

27.6

20.4

24

V

DC – Supply 24 V ± 15 %In case of rectified voltage supply (from AC to DC)The residual ripple should be smaller than 1 V.

a

1.4..1.8 Nm

3.5..4 Nm

1.. 1.2 Nm

TORQUES

P3P-R…..00G

P3P-R….06D

P3P-R….07D

b

Max

.1V

494689 P3P-R Pressure Regulator

5

INSTALLATION AND ELECTRICALCONNECTIONS

INSTALLATIONBefore connecting the regulator P3P-R,pay attention to the following instructions:- Connect the regulator as close aspossible to the apparatus which will beregulated (resulting in higher precision andshorter response times);- Piping section of pressure supply shouldbe sufficiently large;- Connect the air filter (25-50µ, Dew point 2°C) upstream from the regulator, and alubrificator if necessary, downstream;- It is recommended to mount the regulatorin a vertical position, electronic on top.With a flat mounting plate or an anglemounting plate (accessories), connect theregulator to the pneumatic network.Connect the pressure supply on the inletport P and the regulation circuit with theoutlet port A.It is recommended to use a silencer in theexhaust R of types P3P-RJ…...

ELECTRICAL CONNECTIONSThe P3P-R program offers two connectionpossibilities:- by means of a cable gland Pg 13.5 andscrew terminals on the printed circuit plate;- by means of a DIN circular plug-inconnector with crimp contacts.A wire section of 0.75 mm2 isrecommended for the 24 V = power supply,a shielded cable for the control signal.

Power supplyDirect current 24V ±15%(details see page 4).

Electrical connection diagramsSee page 2.Ensure that both "supply" and "control"groundings are not interconnected outsidethe P3P-R as they are already connectedinternally.

Wire coloursPole➀ = BK (black, supply voltage - )Pole➁ = YE (yellow, output signalI / alarm +)Pole➂ = RD (red, supply voltage + )Pole➃ = BN (brown, output signal U + )Pole➄=WH (white, control signal - )Pole➅= BU (blue, control signal + )

1.0. Pg 13.5 CABLE GLANDCONNECTION- To access the screw terminals, firstremove the plastic cover by unscrewingboth cross-head tapping screws.- Pass the cable through the cable glandPg 13.5.- Connect the wires on the screw

terminals according to the electricaldiagram.

- Put on the cover and fasten it with thetapping screws. Screw in the first turnof the thread by hand, then with ascrew-driver screw down with a torqueof 1 Nm.

- Position the cable and fasten it by thecable gland screw.- Set up the inlet pressure(max. 12 bar).

1.1. Serie P3P-R…….GSupply voltage 24 V-DC:Pole ( - ) on terminal GndPole ( + ) on terminal 24 VControl signal U or l:Pole ( - ) on terminal GndPole ( + ) on terminal CTRL

2.0. CIRCULAR PLUG-IN CONNECTION(for series P3P-R…….D)- The electrical connection of the pressureregulator is obtained by a 6-pole circularplug-in connector with crimp contacts.- It is not necessary to remove the cover.The P3P-R is equipped with a mountedplug-in connector.- The contact positions are marked with (1)to (6) on the pin socket (6 poles +grounding).- Crimp the pin-contacts and insert them inthe pin socket according to the electricaldiagrams.- Position the cable, fasten it by the cablegland and mount the plug on the regulator.- Set up the inlet pressure (max.12 bar).

2.1. Serie P3P-R……6Dwith output module(0 - 10 V and 4 - 20 mA)Supply voltage 24 V-DC:Pole ( - ) pin ➀Pole ( + ) pin ➂Control signal U or l:Pole (-) pin ➄Pole (+) pin ➅Sensor output signal 0 - 10 V:

Pole ( - ) pin ➄Pole ( + ) pin ➃Sensor output signal 4 - 20 mA:Pole (-) pin ➄Pole (+) pin ➁

2.2. Serie P3P-R……7Dwith output module(0 - 10 V and alarm 0/24 V)Supply voltage 24 V-DC:Pole ( - ) pin ➀Pole (+) pin ➂Control signal U or l:Pole ( - ) pin ➄Pole (+) pin ➅Sensor output signal 0 - 10 V:Pole ( - ) pin ➄Pole (+) pin ➃Alarm output signal 0/24 V-DC:Pole (-) pin ➄Pole (+) pin ➁

Recommended load resistancesSensor output signal 0-10 V:10 kΩ min.Sens. output signal 4-20 mA:500 Ω max.Alarm output signal 0/24 V: 1.2 kΩ min.

P3P-R SETTING INSTRUCTIONS

The P3P-R regulators are fully adjustedand quality controlled at the factory toobtain standard specifications.

Control signal:0 to 10 Volt or 4 to 20 mA corresponding toan output pressure range of 0.2 to 10 bar(1 V resp. 5.6 mA correspondsto 1 bar).

Hysteresis:~ 100 mbar. This value is adjusted in orderto obtain an inaudible correction of the two2-way solenoid pilots when there is nochange of the control signal.

Setting corrections:In case where the original calibration wouldnot fully correspond to the required setting(e.g.: variation due to the temperature), acorrection may be made by the user. Toaccess the base circuit plate and itspotentiometers, first remove the plasticcover.

Base printed board assembly:P1 = Calibration of control signal

0 - 10 V / 4 - 20 mAP2 = Zero pressure offsetP3 = HysteresisSetting up all other sealed potentiometersis strictly forbidden. Any action on thesealed potentiometers would be subject toa loss of warranty. Parker Pneumaticreserves all rights to modify the position ofthe potentiometers on the electronicpackages.

Output signal module:P6 = 0utput signal 0 - 10 V

(correction of amplitude)P7 = 0ffset correction 0 - 10 VP8 = 0ffset shifting correction

for 4 - 20 mAP9 = Alarm setting up 0/24 VThe setting of the output signal module isonly possible within certain limits.

Attention: Take care to set up only theindicated potentiometers on page 3,according to instructions. For carrying outthe set up, it is necessary to have aVoltage and/or Current Multimeter as wellas a precision manometer or a pressuresensor with digital display. The P3P-R.should be pressurized and energizedexcept when setting up the alarm.

494689 P3P-R Pressure Regulator

6

MAINTENANCEThe P3P-R does not need any maintenance. However thequality of used air should be checked periodically. Forrevision use spare parts kits as follows:

Kit P3P-R Type Order N°

a*

P3P-RJ..C….P3P-RP..C…..

481203-193

P3P-RP..T….. 481203-215

b* P3P-J..C…. 481203-194

Before carrying out the replacement of spare parts with the help ofKits "b", please contact the factory for agreement. It needs KnowHow and special test apparatus. Furthermore the warrantyconditions should be re-defined.

See page 4

SET UP METHOD

Modifications of setting up are permitted only for:- hysteresis;- alarm level.However if a correction of the calibration or a zero offsetcorrection cannot be avoided, proceed first to the calibrationset up and then to the pressure offset. Position of set uppotentiometers on the printed circuit plates are as shown onpage 3.All P3P-R base circuit plates are equipped with the samepotentiometers. The following instructions are therefore validfor the ranges P3P-R..00G, 06D and 07D.To access the base circuit plate, first remove the plasticcover by unscrewing off both cross-head screws. For theseries with integrated output module - types P3P-R..06D and07D -first pull out the upper outlet signal plate from its guideslot. The base electronic package is now accessible.Do not displace this printed board assembly during the set upof the potentiometers. The factory set up of the hysteresiscorresponds to approx. 100 mbar. After carrying out the setup, reset the output module in the guide slots and screw onthe plastic cover.

Forced exhaustThe P3P-R regulator is equipped with an electronic safetycircuit which automatically drops the output pressure at 0 barwhen the control signal is below 130 mV ± 30 mV or 4.26 mA± 0.06 mA. Therefore no setting up should be done when thecontrol signal is below the above-mentioned value. Anymodification of zero pressure offset should be doneaccordingly.

Time lag relayTo neutralize the alarm output signal during the control signalchanges, the use of a synchronized time lag relay isnecessary. The duration of the time lag has to be defined bythe customer in function of each pneumatic installation.

Attention: It is compulsory to set the control signal at 0 V or4 mA each time an installation is turned off (during the nightor the weekend) if the inlet pressure is equally shut down.When the installation cannot be fully exhausted, it isnecessary to assure that the deviation between the controlvalue and the inlet pressure remains smaller than 1 bar.

It is recommended to reset the control signal at 0 V or 4 mArespectively before re-connecting the supply voltage(24 VDC).

BASIC CIRCUIT

Start

Apply the maximum control signal

correct pressure? If yesIf no

Adjust P1

Apply a control signal = 0

Apply a control signal = 1 V or 4.5 mA

Correct pressure? If noIf yes Adjust P2

End

This loop should be repeated as many times as necessary (average 5 to 6times)

NEVER TOUCH P4 AND P5

OPTIONS

Start 0-10 V voltage output

Apply the maximum control signal

Is the output voltage correct? If yes)If no

Adjust P6 (calibration

Apply a control signal = 0

Apply a control signal = 1 V or 4.5 mA

Is the output voltage correct ?If yes If no

Adjust P7 (offset)

Alarm output option 4-20 mA output option

Discharge the inlet pressure and vent the circuitin which the P3P-R is installed

Apply a control signal corresponding tothe required alarm level

Adjust P9 to check the alarm signal activation

Reduce the control signal level and slowly increase it againto check the alarm activation at the required level

Correct ? NoYes End

Apply a control signal = 0 V or 4 mA

Adjust P8 (offset of 4-20 mA) to get a correspondingoutput current of 4 mA.

End

494689 P3P-R Pressure Regulator

Parker Hannifin plc Parker Pneumatic DivisionPneumatic Division Richland, Michigan, USAWalkmill Lane, Bridgtown Phone: (616) 629 5000Cannock, Staffs, WS11 3LR Fax: (616) 629 5385Tel: 01543 456000Fax: 01543 456001

InstallationThe valve should be installed with reasonable accessibility for servicewhenever possible – repair service kits are available. Keep pipe ortubing lengths to a minimum with inside clean and free of dirt andchips. Pipe joint compound should be used sparingly and appliedonly to the male pipe – never into the female port. Do not use PTFEtape to seal pipe joints – pieces have a tendency to break off andlodge inside the unit, possibly causing malfunction.

Application LimitsOperating Pressure Range:

kPa psig barMaximum Inlet 1034 150 10.3Minimum Output 42 6 0.4

Ambient Temperature Range: 0°C to 60°C (32°F to 140°F)Voltage Range: +10%, -10% of Rating

MaterialsBody, Bottom and Top Plates ......................................... AluminumDivider ............................................................................. AluminumPiston .................................................................................... Ace ta lPoppet ............................................................................. AluminumPoppet Seal ...............................................................FluorocarbonSeals ...................................................................................... Ni t r i leSpring ..................................................................... Stainless Steel

Standard Operation1. Blow out the pipe line to remove scale, residue and other

contaminants prior to the installation of the unit.

2. Install the supply of air to the 1/2” (other port sizes available) portmarked IN. It is recommended to use a 1/2” filter upstream of thevalve for maximum protection against foreign matter such as rustand scale. Install the filter as close as practical to the valve. Also,if pressure fluctuation is a common problem at your location, aregulator placed upstream of the inlet will eliminate this problem.

3. Install a 1/2” (other port sizes available) muffler in the exhaustport marked EXH to reduce the noise level.

4. Connect the 1/2” (other port sizes available) outlet port markedOUT to the supply side of the system requiring multiple pressures.If desired, a pressure gauge can be installed downstream of theoutlet port. A gauge isolator should be used to protect the gaugefrom pulsating pressures.

5. If the valve is solenoid operated verify that the solenoid piloting isthe option desired (internally piloted vs. externally piloted), if notperform one of the following conversions:

CONVERSION FROM INTERNAL SOLENOID PILOT SUPPLY TOEXTERNAL SOLENOID PILOT SUPPLY. Remove the 3/8” pipe plugfrom the bottom of the unit and the 1/8” pipe plug from port X1 or X2.Install 1/8” plug and then 3/8” pipe plug in bottom of unit.CONVERSION FROM EXTERNAL SOLENOID PILOT SUPPLY TOINTERNAL SOLENOID PILOT SUPPLY. Remove the 3/8” pipe plugand 1/8” pipe plug from the bottom of the unit. Install the 1/8” pipeplug in port X1 on units with Normally Closed Solenoid Operators orX2 on units with Normally Open Solenoid Operators.6. Connect the pilot signal/supply as follows:REMOTE PILOT SIGNAL OPERATED VALVES. Connect port 2 of a1/8” or smaller 3-Way valve (normally closed or normally open) toeach remote pilot port on top of the valve (numbered 1, 2, 4, and 8).Skip steps 7 and 8.INTERNALLY PILOTED SOLENOID OPERATED VALVES. Pilot supplyis internal. No additional connections are necessary.EXTERNALLY PILOTED SOLENOID OPERATED VALVES. Connectpilot supply air to port X1 for units with normally closed solenoidoperators or X2 for units with normally open solenoid operators.A filter is recommended upstream of the X port and if pressurefluctuation is a problem a regulator is also recommended.Note: Port C is used with cascading described later in this

bulletin. It must be left unplugged if this feature is not desired.On solenoid operated valves one of the X ports serves as thepilot exhaust and should not be plugged. This is X2 for valveswith normally closed solenoid operators and X1 for valveswith normally open solenoid operators.

7. Select the mode of electrical connection that you ordered –no enclosure, enclosure without 6-Pin receptacle, enclosure with6-Pin receptacle, or enclosure with 6-Pin receptacle and lamps.Follow instructions shown on following page.

Installation & Service InstructionsV-630CP

PAR™-15 Valve

ISSUED: August, 2002Supersedes: May, 2001Doc.# V-630P, ECN# 020330, Rev. 4

Pneumatic DivisionRichland, Michigan 49083

!

! WARNINGTo avoid unpredictable system behavior that can cause personal injuryand property damage:

• Disconnect electrical supply (when necessary) before installation,servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected tothis product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is belowfreezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must beperformed by knowledgeable personnel who understand howpneumatic products are to be applied.

• After installation, servicing, or conversion, air and electricalsupplies (when necessary) should be connected and the producttested for proper function and leakage. If audible leakage is present,or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be coveredby paint, etc. If masking is not possible, contact your localrepresentative for replacement labels.

WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OFTHE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN ORRELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY ANDPROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation,its subsidiaries and authorized distributors provide product and/orsystem options for further investigation by users having technicalexpertise. It is important that you analyze all aspects of your application,including consequences of any failure and review the informationconcerning the product or systems in the current product catalog. Dueto the variety of operating conditions and applications for these productsor systems, the user, through its own analysis and testing, is solelyresponsible for making the final selection of the products and systemsand assuring that all performance, safety and warning requirementsof the application are met.The products described herein, including without limitation, productfeatures, specifications, designs, availability and pricing, are subjectto change by Parker Hannifin Corporation and its subsidiaries at anytime without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FORINCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZETHESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

PAR™-15 Valve V-630CP

UNITS WITH NO ENCLOSUREConnect input and common signals to eachone of the solenoids marked with the binaryinputs 1, 2, 4 and 8, using the 3-Pin femaleconnector kits shown in the catalog. Followthe installation instructions included withthe 3-Pin female connector kits for theproper installation.

If you elect not to use the 3-Pin femaleconnector kits, you may use three femalespade connectors per solenoid and connectthe wires as shown on the figure.

Wiring – Follow all local and national electrical codes.

UNITS WITH ENCLOSURE AND WITHOUT 6-PIN RECEPTACLEConnect input and common signals to the terminal block on thecircuit board labelled TB1. Connect each solenoid input (1, 2, 4, & 8)to the respective label on the circuit board. Connect each common tothe input labelled C on the circuit board.

UNITS WITH ENCLOSURE AND 6-PIN MICRO RECEPTACLEThese units use the following brand names for 6-Pin micro connectors:

ConnectorBrand Name Receptacle w/ 6 Foot Cord

Brad Harrison 7R6006A19A120 706000D02F060Joy 5000127-41 5000127-2

Connection is made as shown in the chart below.

Pin Wire Color Function

1 Red-White Input 1

2 Red Input 2

3 Green Equipment Ground

4 Red-Yellow Common

5 Red-Black Input 8

6 Red-Blue Input 4

UNITS WITH ENCLOSURE AND 6-PIN MINI CONNECTORThese units use either one of the following brand names for 6-Pin miniconnectors:

ConnectorBrand Name Receptacle w/ 6 Foot Cord

Brad Harrison 42605 42602Joy X8987-2 X8987-4

Connection is made as shown in the chart below.

Pin Wire Color Function

1 Orange Input 1

2 Blue Input 2

3 Black Input 4

4 White Common

5 Red Input 8

6 Green Equipment Ground

UNITS WITH ENCLOSURE, 6-PIN CONNECTOR ANDINDICATOR LAMPSEach indicator lamp signals when the corresponding solenoid operatoris actuated. Lamps that fail to light may need to be replaced or acheck made to see if a connection has become loose.

Follow the service kit instructions included with the repair kits forproper installation of replacement lamps.

For units with DC solenoids and indicator lamps red wire is (+)positive black wire is (-) negative.

Caution: DC solenoids with indicator lamps are polaritysensitive. Observe polarities indicated above.

AVAILABLE LAMPS

Description Part Number

Lamp (120/60AC) with spring clip K352428C

Lamp (24VDC) with spring clip K352429C

SOLENOID

(EQUIPMENTGROUND)

2 1

1

2

3

4

5

6

12

3

45

6

2

!

X1 X2C

EXH

IN

2.69(68)

1.69(43)

.69(18)

4.87(124)

C

4.69(119)

4.69(119)

7.68(195)

1.94(49)

3.38(86)

4.34(110)

6.88(175)

1.04(26)

.69(18)

1.86 (47)*

OverallHeight

(See Table)

2.31(59)

1.94(49)

3.94(100)

2.52(64)

1.06(27)

.328 Dia. Thru

.50 Dia. X .31 Dp.C’ Bore-Both Ends(2 Places-Except3/4" Ported Versions)

OUT

1/2"Pipe Port(3 Places)

1/8" Pipe Ports(3 Places)

1.86(47)*

Description Overall Height

Solenoid w/Lamp 7.93 (201)

Solenoid w/o Lamp 7.83 (199)

Remote Pilot 5.85 (149)

* 1.92 (48)with 3/4" Ports

WIRING DIAGRAMS:

8. Reorientation of the 6-Pin electrical connector and cover is possibleby removing the two screws on top of the cover and rotating thecover 180°. See diagram below. Replace the cover and screws.

Narrow Band Control OperationThe valve can also be used to provide a narrower band of outputpressures with the lowest selected pressure greater than zero.

REMOTE PILOT SIGNAL OPERATED VALVES

1. Connect the output of a 1/8” relieving regulator to port 1 of each ofthe four 3-way valves.

2. Connect the output of a 1/8” relieving regulator to port 3 of each ofthe 3-way valves.

SOLENOID OPERATED VALVE

1. Convert the valve to external pilot operation as mentioned aboveunder standard operation. Skip this step if the valve was orderedexternally piloted from the factory.

2. Two 1/8” relieving regulators will be required. If 0 PSIG pressure isneeded then a 3-way normally closed solenoid valve is alsorequired.

3. Connect the output of one regulator to the 1/8” port marked X1.See Narrow Band Control diagram.

NARROW BAND CONTROL DIAGRAM

4. Connect the output of the second regulator to the 1/8” port markedX2. If 0 PSIG pressure is needed then connect the output of thesecond regulator to the inlet of the 3-way normally closed valve,and connect the outlet of the 3-Way normally closed valve to the 1/8” port marked X2. See Narrow Band Control diagram.

5. Do not plug the 1/8” port marked C.

Cascading OperationTwo valves can also be used in conjunction to provide 240 steps(versus 15 steps from one valve), therefore, providing more outputpressures.

INTERNALLY PILOTED SOLENOID OPERATED VALVES ONLY*

1. Follow steps 1, 2 & 3 above under Standard Operation foreach valve.

2. Connect the outlet port marked OUT of the valve upstream toeither of the 1/8” ports marked C of the valve downstream. SeeCascading diagram below. A port/pipe reducer(s) must be used toaccomplish this task. If desired, a pressure gauge can be installedbetween these two points. A gauge isolator should be used toprotect the gauge from pulsating pressures.

CASCADING DIAGRAM

3. Connect the outlet port marked OUT of the valve downstream tothe supply side of the system requiring multiple pressures. If desired,a pressure gauge can be installed downstream of the outlet port.A gauge isolator should be used to protect the gauge from pulsatingpressures.

4. Do not plug the 1/8” ports marked C and X2 on the valve upstreamand X2 on the valve downstream.

5. Follow steps 6 & 7 above under Standard Operation to finish theinstallation.

* For remote pilot operated or solenoid operated with external pilotsupply consult factory.

Life Expectancy – Normal multi-million cycle life expectancy of thesevalves is based on the use of properly filtered air at room temperature.

Lubrication – Although the valve does not require lubrication for anormal service life, use of SAE 10 mineral base oil is recommendedto extend component life. This should be supplied using a 1/2” fullflow lubricator located upstream of the valve inlet port.

Caution: Do not use synthetic, reconstituted, or oils with analcohol content.

Operation and ServiceStandard Operation

1. Select the mode of operation you want to use – remote pilot,internal pilot or external pilot.

REMOTE PILOT SIGNAL OPERATED ONLY

Actuation of each 3-way valve selectively divides any input pressureinto any of 15 equally spaced pressures plus zero. See Truth Table.

INTERNALLY PILOTED SOLENOID OPERATED ONLY

Four solenoids are controlled by on/off signals that selectively divideany input pressure into any of 15 equally spaced pressures plus zero.See the Truth Table.

EXTERNALLY PILOTED SOLENOID OPERATED ONLY

Four solenoids are controlled by on/off signals that selectively divideany input pressure to the X1 port into any of 15 equally spacedpressures plus zero, independent of mainline supply pressure to theIN port so long as the X1 port pressure is set at a pressure below themainline supply pressure. See the Truth Table.

Caution: An interruption of 10 milliseconds or greater tothe power supplied to the solenoid of a solenoid operatedvalve may cause the valve to shift. Provision must be madeto prevent power interruption of this duration to avoidunintended, potentially hazardous, consequences.

PAR™-15 Valve V-630CP

Quadrant 4Quadrant 2

180˚

Upper BandLimit

EXH

X2

X1EXH IN

OUT

Lower BandLimit

IN

IN

EXH

EXH

OUT

OUT

C

DownstreamValve240 Steps

UpstreamValve15 Steps

3

!

!

RED

WHTGRN

SOL 4

ORG

3 64

BLU

BLK

SOL 8

COM

SOL 2

SOL 1

4

RED

BLACK

RED

8

C

2

1 1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

BLACK

RED

BLACK

BLACK

RED

RED-BLU

RED-BLK

RED

GREEN RED-YEL

GRN

SOL 4

RED-WHT

3

2 1

5

2 1

5

2 1

5

64

BLU

SOL 8

COM

SOL 2

SOL 1

4

RED

BLACK

RED

8

C

2

1

BLACK

RED

BLACK

BLACK

RED

RED

WHTGRN

SOL 4

ORG

3 64

BLU

BLK

SOL 8

COM

SOL 2

SOL 1

4

8

C

2

1BLACK

REDBLACK

RED

BLACK

RED

BLACK

RED

BLACK

REDBLACK

RED

BLACK

RED

BLACK

RED

RED-BLU

RED-BLK

RED

GREENRED-YEL

GRN

SOL 4

RED-WHT

3

2 1

56

4

BLU

SOL 8

COM

SOL 2

SOL 1

4

8

C

2

1

120 VAC Mini Connector 120 VAC Micro Connector

24 VDC Mini Connector 24 VDC Micro Connector

L1

L2

L3

L4

(TB2)

(TB1)

CONNECTOR

LIGHTS

1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

L1

L2

L3

L4

(TB2)

(TB1)

LIGHTS

1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

L1

L2

L3

L4

(TB2)

(TB1)

LIGHTS

1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

L1

L2

L3

L4

(TB2)

(TB1)

CONNECTOR

LIGHTS

CONNECTOR

CONNECTOR

2. The valve is available with two types of output pressure regulation:increasing output and decreasing output. Follow the instructionsthat pertain to the type of solenoids that you ordered – normallyclosed or normally open.

NORMALLY CLOSED SOLENOIDS ONLYIn the increasing output pressure regulation type, normally closedsolenoid operators are used to divide the input pressure into15 equal steps, ranging from 0 PSIG (all solenoid operatorsde-energized) to full line pressure (all solenoid operators energized).Continue with step 3.

NORMALLY OPEN SOLENOIDS ONLYIn the decreasing output pressure regulation type, normally opensolenoid operators are used to divide the input pressure into15 equal steps, starting with full line pressure (all solenoid operatorsde-energized) and ending with 0 PSIG (all solenoid operatorsenergized).

Caution: Interruption of the electrical signal to a decreasingoutput pressure regulation type valve will cause full linepressure to be present at the output port.

3. Full flow exhaust permits instant reduction to any lower selectedpressure or zero. High relief capacity quickly vents downstreamoverpressure. The output pressure will begin to change within 20milliseconds after a change in the electrical input to one or more ofthe solenoids. However, the time which elapses until the outputpressure reaches the new level will depend upon the volume of air,the size of the connection from the unit and the magnitude of thepressure change.

4. For reliable performance, adherence to the rated minimum outputpressure is recommended.

Narrow Band Control Operation1. Set the regulator connected to Port 1 of the 3-Way valves (remote

pilot only) or to the X1 port to the upper pressure of the range thatyou have selected.

2. Set the regulator connected to Port 3 of the 3-Way valves (remotepilot only) or to the X2 port to the lower pressure of the range thatyou have selected.

3. A formula can be used to calculate the value of one step.

One Step =Upper Pressure (PSIG) — Lower Pressure (PSIG)

154. If a 3-way normally closed valve was installed as mentioned above

to attain a 0 PSIG reading, then for:

NORMALLY CLOSED SOLENOIDS ONLY

Simultaneously de-energize the 3-way valve and all four solenoids atthe binary valve to exhaust all air supply to the solenoids and get a 0PSIG reading at the output of the binary valve. Energize the 3-wayvalve in order to operate the binary valve at the lower pressure of therange selected.

NORMALLY OPEN SOLENOIDS ONLY

Simultaneously de-energize the 3-way valve and energize all foursolenoids at the binary valve to exhaust all air supply to the solenoidsand get a 0 PSIG reading at the output of the binary valve. Energizethe 3-way valve in order to operate the binary valve at the lowerpressure of the range selected.

Example:

Line pressure in the plant equals 150 PSIG. The customer is interestedin operating the binary valve between 25 PSIG and100 PSIG in order to reduce the value of one step, i.e. at full linepressure one step equals 150/15 or 10 PSIG, and have more flexibilitywithin the range. What is the value of one step between this pressurerange?

Solution:

Set regulator connected to the X1 port to 100 PSIG. Set regulatorconnected to the X2 port to 25 PSIG. One step is now equal to:

One Step =100 – 25

=75

= 5 PSIG15 15

Cascading Operation1. Operation of the valves is the same as mentioned above under the

Standard Operation for internal pilot valves.

2. See Cascading Truth Table for the proper input signal to eachsolenoid, and the resulting proportion of inlet pressure for an outputpressure.

3. A formula can be used to calculate the output pressure of the valvedownstream.

Output Pressure(PSIG)

Line Pressure(PSIG)

15

Binary InputUpstream Valve

16

Binary Input Downstream

Valve+*=

Where:

Line Pressure is the supply pressure to both valves and itmust be equal.

BINARY INPUT UPSTREAM VALVE is the binary number, a numberfrom 0 to 15 depending on which solenoids are energized (normallyclosed solenoids) or de-energized (normally open solenoids) on thevalve upstream.

BINARY INPUT DOWNSTREAM VALVE is the binary number, a numberfrom 0 to 15 depending on which solenoids are energized (normallyclosed solenoids) or de-energized (normally open solenoids) on thevalve downstream.

Example:Assume the line pressure is 120 PSIG, the valve upstream has inputs 1and 2 energized, and the valve downstream has inputs1 and 8 energized. Also, assume normally closed solenoids.What is the output pressure of the valve downstream?

Solution:

Binary Input valve upstream = 1+2=3Binary Input valve downstream = 1+8=9

Output Pressure =120

153

16+ 9 = 8 * 9.1875 = 73.5 PSIG*

PAR™-15 Valve V-630CP

Truth TableNormallyClosedValves/

Solenoids

NormallyOpen Valves/

Solenoids

Binary Input*8 4 2 1

Pin Number †5 3 2 1

Binary Input*8 4 2 1

Pin Number †5 3 2 1

Proportionof Inlet

Pressure

PSIG Output@ 75 PSIG

Inlet ††

PSIGOutput @ 90

PSIG Inlet

0 0 0 0 1 1 1 1 0 0 0

0 0 0 1 1 1 1 0 1/15 5 6

0 0 1 0 1 1 0 1 2/15 10 12

0 0 1 1 1 1 0 0 3/15 15 18

0 1 0 0 1 0 1 1 4/15 20 24

0 1 0 1 1 0 1 0 5/15 25 30

0 1 1 0 1 0 0 1 6/15 30 36

0 1 1 1 1 0 0 0 7/15 35 42

1 0 0 0 0 1 1 1 8/15 40 48

1 0 0 1 0 1 1 0 9/15 45 54

1 0 1 0 0 1 0 1 10/15 50 60

1 0 1 1 0 1 0 0 11/15 55 66

1 1 0 0 0 0 1 1 12/15 60 72

1 1 0 1 0 0 1 0 13/15 65 78

1 1 1 0 0 0 0 1 14/15 70 84

1 1 1 1 0 0 0 0 15/15 75 90

Table above illustrates available output pressures for inlet pressures of75 PSIG and 90 PSIG. Inlet pressure may be any value between 15 and150 PSIG. Output pressure increment will be 1/15 of inlet pressure.*0 = Voltage “OFF”1 = Voltage “ON”

† Available only on units with 6-Pin connector.†† Shaded output pressures shown are theoretical and are below the

minimum operating range of the valve and should not be used.Please refer to the Engineering Specifications for minimum output.

Maintenance Service KitService Kit K352413

4

!

Cascading Truth TableNormally Closed Solenoids Normally Open SolenoidsDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveBinary Input *

8 4 2 1 8 4 2 1Binary Input *

8 4 2 1 8 4 2 1 Proportion Proportion PSIG Output PSIG OutputStep PIN Number †

5 3 2 1 5 3 2 1PIN Number †

5 3 2 1 5 3 2 1of Inlet

Pressureof Inlet

Pressure@ 60 PSIG

Inlet †† Inlet ††

@ 120 PSIG

0 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0.00 0.001 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 1/240 0.25 0.502 0 0 0 0 0 0 1 0 1 1 1 1 1 1 0 1 0 2/240 0.50 1.003 0 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 3/240 0.75 1.504 0 0 0 0 0 1 0 0 1 1 1 1 1 0 1 1 0 4/240 1.00 2.005 0 0 0 0 0 1 0 1 1 1 1 1 1 0 1 0 0 5/240 1.25 2.506 0 0 0 0 0 1 1 0 1 1 1 1 1 0 0 1 0 6/240 1.50 3.007 0 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 7/240 1.75 3.508 0 0 0 0 1 0 0 0 1 1 1 1 0 1 1 1 0 8/240 2.00 4.009 0 0 0 0 1 0 0 1 1 1 1 1 0 1 1 0 0 9/240 2.25 4.5010 0 0 0 0 1 0 1 0 1 1 1 1 0 1 0 1 0 10/240 2.50 5.0011 0 0 0 0 1 0 1 1 1 1 1 1 0 1 0 0 0 11/240 2.75 5.5012 0 0 0 0 1 1 0 0 1 1 1 1 0 0 1 1 0 12/240 3.00 6.0013 0 0 0 0 1 1 0 1 1 1 1 1 0 0 1 0 0 13/240 3.25 6.5014 0 0 0 0 1 1 1 0 1 1 1 1 0 0 0 1 0 14/240 3.50 7.0015 0 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 15/240 3.75 7.50

16 0 0 0 1 0 0 0 0 1 1 1 0 1 1 1 1 1/15 0 4.00 8.0017 0 0 0 1 0 0 0 1 1 1 1 0 1 1 1 0 1/15 1/240 4.25 8.5018 0 0 0 1 0 0 1 0 1 1 1 0 1 1 0 1 1/15 2/240 4.50 9.0019 0 0 0 1 0 0 1 1 1 1 1 0 1 1 0 0 1/15 3/240 4.75 9.5020 0 0 0 1 0 1 0 0 1 1 1 0 1 0 1 1 1/15 4/240 5.00 10.0021 0 0 0 1 0 1 0 1 1 1 1 0 1 0 1 0 1/15 5/240 5.25 10.5022 0 0 0 1 0 1 1 0 1 1 1 0 1 0 0 1 1/15 6/240 5.50 11.0023 0 0 0 1 0 1 1 1 1 1 1 0 1 0 0 0 1/15 7/240 5.75 11.5024 0 0 0 1 1 0 0 0 1 1 1 0 0 1 1 1 1/15 8/240 6.00 12.0025 0 0 0 1 1 0 0 1 1 1 1 0 0 1 1 0 1/15 9/240 6.25 12.5026 0 0 0 1 1 0 1 0 1 1 1 0 0 1 0 1 1/15 10/240 6.50 13.0027 0 0 0 1 1 0 1 1 1 1 1 0 0 1 0 0 1/15 11/240 6.75 13.5028 0 0 0 1 1 1 0 0 1 1 1 0 0 0 1 1 1/15 12/240 7.00 14.0029 0 0 0 1 1 1 0 1 1 1 1 0 0 0 1 0 1/15 13/240 7.25 14.5030 0 0 0 1 1 1 1 0 1 1 1 0 0 0 0 1 1/15 14/240 7.50 15.0031 0 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 1/15 15/240 7.75 15.50

32 0 0 1 0 0 0 0 0 1 1 0 1 1 1 1 1 2/15 0 8.00 16.0033 0 0 1 0 0 0 0 1 1 1 0 1 1 1 1 0 2/15 1/240 8.25 16.5034 0 0 1 0 0 0 1 0 1 1 0 1 1 1 0 1 2/15 2/240 8.50 17.0035 0 0 1 0 0 0 1 1 1 1 0 1 1 1 0 0 2/15 3/240 8.75 17.5036 0 0 1 0 0 1 0 0 1 1 0 1 1 0 1 1 2/15 4/240 9.00 18.0037 0 0 1 0 0 1 0 1 1 1 0 1 1 0 1 0 2/15 5/240 9.25 18.5038 0 0 1 0 0 1 1 0 1 1 0 1 1 0 0 1 2/15 6/240 9.50 19.0039 0 0 1 0 0 1 1 1 1 1 0 1 1 0 0 0 2/15 7/240 9.75 19.5040 0 0 1 0 1 0 0 0 1 1 0 1 0 1 1 1 2/15 8/240 10.00 20.0041 0 0 1 0 1 0 0 1 1 1 0 1 0 1 1 0 2/15 9/240 10.25 20.5042 0 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 2/15 10/240 10.50 21.0043 0 0 1 0 1 0 1 1 1 1 0 1 0 1 0 0 2/15 11/240 10.75 21.5044 0 0 1 0 1 1 0 0 1 1 0 1 0 0 1 1 2/15 12/240 11.00 22.0045 0 0 1 0 1 1 0 1 1 1 0 1 0 0 1 0 2/15 13/240 11.25 22.5046 0 0 1 0 1 1 1 0 1 1 0 1 0 0 0 1 2/15 14/240 11.50 23.0047 0 0 1 0 1 1 1 1 1 1 0 1 0 0 0 0 2/15 15/240 11.75 23.50

48 0 0 1 1 0 0 0 0 1 1 0 0 1 1 1 1 3/15 0 12.00 24.0049 0 0 1 1 0 0 0 1 1 1 0 0 1 1 1 0 3/15 1/240 12.25 24.5050 0 0 1 1 0 0 1 0 1 1 0 0 1 1 0 1 3/15 2/240 12.50 25.0051 0 0 1 1 0 0 1 1 1 1 0 0 1 1 0 0 3/15 3/240 12.75 25.5052 0 0 1 1 0 1 0 0 1 1 0 0 1 0 1 1 3/15 4/240 13.00 26.0053 0 0 1 1 0 1 0 1 1 1 0 0 1 0 1 0 3/15 5/240 13.25 26.5054 0 0 1 1 0 1 1 0 1 1 0 0 1 0 0 1 3/15 6/240 13.50 27.0055 0 0 1 1 0 1 1 1 1 1 0 0 1 0 0 0 3/15 7/240 13.75 27.5056 0 0 1 1 1 0 0 0 1 1 0 0 0 1 1 1 3/15 8/240 14.00 28.0057 0 0 1 1 1 0 0 1 1 1 0 0 0 1 1 0 3/15 9/240 14.25 28.5058 0 0 1 1 1 0 1 0 1 1 0 0 0 1 0 1 3/15 10/240 14.50 29.0059 0 0 1 1 1 0 1 1 1 1 0 0 0 1 0 0 3/15 11/240 14.75 29.5060 0 0 1 1 1 1 0 0 1 1 0 0 0 0 1 1 3/15 12/240 15.00 30.0061 0 0 1 1 1 1 0 1 1 1 0 0 0 0 1 0 3/15 13/240 15.25 30.5062 0 0 1 1 1 1 1 0 1 1 0 0 0 0 0 1 3/15 14/240 15.50 31.0063 0 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 3/15 15/240 15.75 31.50

+

PAR™-15 Valve V-630CP

5

64 0 1 0 0 0 0 0 0 1 0 1 1 1 1 1 1 4/15 0 16.00 32.0065 0 1 0 0 0 0 0 1 1 0 1 1 1 1 1 0 4/15 1/240 16.25 32.5066 0 1 0 0 0 0 1 0 1 0 1 1 1 1 0 1 4/15 2/240 16.50 33.0067 0 1 0 0 0 0 1 1 1 0 1 1 1 1 0 0 4/15 3/240 16.75 33.5068 0 1 0 0 0 1 0 0 1 0 1 1 1 0 1 1 4/15 4/240 17.00 34.0069 0 1 0 0 0 1 0 1 1 0 1 1 1 0 1 0 4/15 5/240 17.25 34.5070 0 1 0 0 0 1 1 0 1 0 1 1 1 0 0 1 4/15 6/240 17.50 35.0071 0 1 0 0 0 1 1 1 1 0 1 1 1 0 0 0 4/15 7/240 17.75 35.5072 0 1 0 0 1 0 0 0 1 0 1 1 0 1 1 1 4/15 8/240 18.00 36.0073 0 1 0 0 1 0 0 1 1 0 1 1 0 1 1 0 4/15 9/240 18.25 36.5074 0 1 0 0 1 0 1 0 1 0 1 1 0 1 0 1 4/15 10/240 18.50 37.0075 0 1 0 0 1 0 1 1 1 0 1 1 0 1 0 0 4/15 11/240 18.75 37.5076 0 1 0 0 1 1 0 0 1 0 1 1 0 0 1 1 4/15 12/240 19.00 38.0077 0 1 0 0 1 1 0 1 1 0 1 1 0 0 1 0 4/15 13/240 19.25 38.5078 0 1 0 0 1 1 1 0 1 0 1 1 0 0 0 1 4/15 14/240 19.50 39.0079 0 1 0 0 1 1 1 1 1 0 1 1 0 0 0 0 4/15 15/240 19.75 39.50

80 0 1 0 1 0 0 0 0 1 0 1 0 1 1 1 1 5/15 0 20.00 40.0081 0 1 0 1 0 0 0 1 1 0 1 0 1 1 1 0 5/15 1/240 20.25 40.5082 0 1 0 1 0 0 1 0 1 0 1 0 1 1 0 1 5/15 2/240 20.50 41.0083 0 1 0 1 0 0 1 1 1 0 1 0 1 1 0 0 5/15 3/240 20.75 41.5084 0 1 0 1 0 1 0 0 1 0 1 0 1 0 1 1 5/15 4/240 21.00 42.0085 0 1 0 1 0 1 0 1 1 0 1 0 1 0 1 0 5/15 5/240 21.25 42.5086 0 1 0 1 0 1 1 0 1 0 1 0 1 0 0 1 5/15 6/240 21.50 43.0087 0 1 0 1 0 1 1 1 1 0 1 0 1 0 0 0 5/15 7/240 21.75 43.5088 0 1 0 1 1 0 0 0 1 0 1 0 0 1 1 1 5/15 8/240 22.00 44.0089 0 1 0 1 1 0 0 1 1 0 1 0 0 1 1 0 5/15 9/240 22.25 44.5090 0 1 0 1 1 0 1 0 1 0 1 0 0 1 0 1 5/15 10/240 22.50 45.0091 0 1 0 1 1 0 1 1 1 0 1 0 0 1 0 0 5/15 11/240 22.75 45.5092 0 1 0 1 1 1 0 0 1 0 1 0 0 0 1 1 5/15 12/240 23.00 46.0093 0 1 0 1 1 1 0 1 1 0 1 0 0 0 1 0 5/15 13/240 23.25 46.5094 0 1 0 1 1 1 1 0 1 0 1 0 0 0 0 1 5/15 14/240 23.50 47.0095 0 1 0 1 1 1 1 1 1 0 1 0 0 0 0 0 5/15 15/240 23.75 47.50

96 0 1 1 0 0 0 0 0 1 0 0 1 1 1 1 1 6/15 0 24.00 48.0097 0 1 1 0 0 0 0 1 1 0 0 1 1 1 1 0 6/15 1/240 24.25 48.5098 0 1 1 0 0 0 1 0 1 0 0 1 1 1 0 1 6/15 2/240 24.50 49.0099 0 1 1 0 0 0 1 1 1 0 0 1 1 1 0 0 6/15 3/240 24.75 49.50100 0 1 1 0 0 1 0 0 1 0 0 1 1 0 1 1 6/15 4/240 25.00 50.00101 0 1 1 0 0 1 0 1 1 0 0 1 1 0 1 0 6/15 5/240 25.25 50.50102 0 1 1 0 0 1 1 0 1 0 0 1 1 0 0 1 6/15 6/240 25.50 51.00103 0 1 1 0 0 1 1 1 1 0 0 1 1 0 0 0 6/15 7/240 25.75 51.50104 0 1 1 0 1 0 0 0 1 0 0 1 0 1 1 1 6/15 8/240 26.00 52.00105 0 1 1 0 1 0 0 1 1 0 0 1 0 1 1 0 6/15 9/240 26.25 52.50106 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 6/15 10/240 26.50 53.00107 0 1 1 0 1 0 1 1 1 0 0 1 0 1 0 0 6/15 11/240 26.75 53.50108 0 1 1 0 1 1 0 0 1 0 0 1 0 0 1 1 6/15 12/240 27.00 54.00109 0 1 1 0 1 1 0 1 1 0 0 1 0 0 1 0 6/15 13/240 27.25 54.50110 0 1 1 0 1 1 1 0 1 0 0 1 0 0 0 1 6/15 14/240 27.50 55.00111 0 1 1 0 1 1 1 1 1 0 0 1 0 0 0 0 6/15 15/240 27.75 55.50

112 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 1 7/15 0 28.00 56.00113 0 1 1 1 0 0 0 1 1 0 0 0 1 1 1 0 7/15 1/240 28.25 56.50114 0 1 1 1 0 0 1 0 1 0 0 0 1 1 0 1 7/15 2/240 28.50 57.00115 0 1 1 1 0 0 1 1 1 0 0 0 1 1 0 0 7/15 3/240 28.75 57.50116 0 1 1 1 0 1 0 0 1 0 0 0 1 0 1 1 7/15 4/240 29.00 58.00117 0 1 1 1 0 1 0 1 1 0 0 0 1 0 1 0 7/15 5/240 29.25 58.50118 0 1 1 1 0 1 1 0 1 0 0 0 1 0 0 1 7/15 6/240 29.50 59.00119 0 1 1 1 0 1 1 1 1 0 0 0 1 0 0 0 7/15 7/240 29.75 59.50120 0 1 1 1 1 0 0 0 1 0 0 0 0 1 1 1 7/15 8/240 30.00 60.00121 0 1 1 1 1 0 0 1 1 0 0 0 0 1 1 0 7/15 9/240 30.25 60.50122 0 1 1 1 1 0 1 0 1 0 0 0 0 1 0 1 7/15 10/240 30.50 61.00123 0 1 1 1 1 0 1 1 1 0 0 0 0 1 0 0 7/15 11/240 30.75 61.50124 0 1 1 1 1 1 0 0 1 0 0 0 0 0 1 1 7/15 12/240 31.00 62.00125 0 1 1 1 1 1 0 1 1 0 0 0 0 0 1 0 7/15 13/240 31.25 62.50126 0 1 1 1 1 1 1 0 1 0 0 0 0 0 0 1 7/15 14/240 31.50 63.00127 0 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 7/15 15/240 31.75 63.50

Cascading Truth Table (Continued)Normally Closed Solenoids Normally Open SolenoidsDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveBinary Input *

8 4 2 1 8 4 2 1Binary Input *

8 4 2 1 8 4 2 1 Proportion Proportion PSIG Output PSIG OutputStep PIN Number †

5 3 2 1 5 3 2 1PIN Number †

5 3 2 1 5 3 2 1of Inlet

Pressureof Inlet

Pressure@ 60 PSIG

Inlet †† Inlet ††

@ 120 PSIG+

PAR™-15 Valve V-630CP

6

128 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 8/15 0 32.00 64.00129 1 0 0 0 0 0 0 1 0 1 1 1 1 1 1 0 8/15 1/240 32.25 64.50130 1 0 0 0 0 0 1 0 0 1 1 1 1 1 0 1 8/15 2/140 32.50 65.00131 1 0 0 0 0 0 1 1 0 1 1 1 1 1 0 0 8/15 3/240 32.75 65.50132 1 0 0 0 0 1 0 0 0 1 1 1 1 0 1 1 8/15 4/240 33.00 66.00133 1 0 0 0 0 1 0 1 0 1 1 1 1 0 1 0 8/15 5/240 33.25 66.50134 1 0 0 0 0 1 1 0 0 1 1 1 1 0 0 1 8/15 6/240 33.50 67.00135 1 0 0 0 0 1 1 1 0 1 1 1 1 0 0 0 8/15 7/240 33.75 67.50136 1 0 0 0 1 0 0 0 0 1 1 1 0 1 1 1 8/15 8/240 34.00 68.00137 1 0 0 0 1 0 0 1 0 1 1 1 0 1 1 0 8/15 9/240 34.25 68.50138 1 0 0 0 1 0 1 0 0 1 1 1 0 1 0 1 8/15 10/240 34.50 69.00139 1 0 0 0 1 0 1 1 0 1 1 1 0 1 0 0 8/15 11/240 34.75 69.50140 1 0 0 0 1 1 0 0 0 1 1 1 0 0 1 1 8/15 12/240 35.00 70.00141 1 0 0 0 1 1 0 1 0 1 1 1 0 0 1 0 8/15 13/240 35.25 70.50142 1 0 0 0 1 1 1 0 0 1 1 1 0 0 0 1 8/15 14/240 35.50 71.00143 1 0 0 0 1 1 1 1 0 1 1 1 0 0 0 0 8/15 15/240 35.75 71.50

144 1 0 0 1 0 0 0 0 0 1 1 0 1 1 1 1 9/15 0 36.00 72.00145 1 0 0 1 0 0 0 1 0 1 1 0 1 1 1 0 9/15 1/240 36.25 72.50146 1 0 0 1 0 0 1 0 0 1 1 0 1 1 0 1 9/15 2/240 36.50 73.00147 1 0 0 1 0 0 1 1 0 1 1 0 1 1 0 0 9/15 3/240 36.75 73.50148 1 0 0 1 0 1 0 0 0 1 1 0 1 0 1 1 9/15 4/240 37.00 74.00149 1 0 0 1 0 1 0 1 0 1 1 0 1 0 1 0 9/15 5/240 37.25 74.50150 1 0 0 1 0 1 1 0 0 1 1 0 1 0 0 1 9/15 6/240 37.50 75.00151 1 0 0 1 0 1 1 1 0 1 1 0 1 0 0 0 9/15 7/240 37.75 75.50152 1 0 0 1 1 0 0 0 0 1 1 0 0 1 1 1 9/15 8/240 38.00 76.00153 1 0 0 1 1 0 0 1 0 1 1 0 0 1 1 0 9/15 9/240 38.25 76.50154 1 0 0 1 1 0 1 0 0 1 1 0 0 1 0 1 9/15 10/240 38.50 77.00155 1 0 0 1 1 0 1 1 0 1 1 0 0 1 0 0 9/15 11/240 38.75 77.50156 1 0 0 1 1 1 0 0 0 1 1 0 0 0 1 1 9/15 12/240 39.00 78.00157 1 0 0 1 1 1 0 1 0 1 1 0 0 0 1 0 9/15 13/240 39.25 78.50158 1 0 0 1 1 1 1 0 0 1 1 0 0 0 0 1 9/15 14/240 39.50 79.00159 1 0 0 1 1 1 1 1 0 1 1 0 0 0 0 0 9/15 15/240 39.75 79.50

160 1 0 1 0 0 0 0 0 0 1 0 1 1 1 1 1 10/15 0 40.00 80.00161 1 0 1 0 0 0 0 1 0 1 0 1 1 1 1 0 10/15 1/240 40.25 80.50162 1 0 1 0 0 0 1 0 0 1 0 1 1 1 0 1 10/15 2/240 40.50 81.00163 1 0 1 0 0 0 1 1 0 1 0 1 1 1 0 0 10/15 3/240 40.75 81.50164 1 0 1 0 0 1 0 0 0 1 0 1 1 0 1 1 10/15 4/240 41.00 82.00165 1 0 1 0 0 1 0 1 0 1 0 1 1 0 1 0 10/15 5/240 41.25 82.50166 1 0 1 0 0 1 1 0 0 1 0 1 1 0 0 1 10/15 6/240 41.50 83.00167 1 0 1 0 0 1 1 1 0 1 0 1 1 0 0 0 10/15 7/240 41.75 83.50168 1 0 1 0 1 0 0 0 0 1 0 1 0 1 1 1 10/15 8/240 42.00 84.00169 1 0 1 0 1 0 0 1 0 1 0 1 0 1 1 0 10/15 9/240 42.25 84.50170 1 0 1 0 1 0 1 0 0 1 0 1 0 1 0 1 10/15 10/240 42.50 85.00171 1 0 1 0 1 0 1 1 0 1 0 1 0 1 0 0 10/15 11/240 42.75 85.50172 1 0 1 0 1 1 0 0 0 1 0 1 0 0 1 1 10/15 12/240 43.00 86.00173 1 0 1 0 1 1 0 1 0 1 0 1 0 0 1 0 10/15 13/240 43.25 86.50174 1 0 1 0 1 1 1 0 0 1 0 1 0 0 0 1 10/15 14/240 43.50 87.00175 1 0 1 0 1 1 1 1 0 1 0 1 0 0 0 0 10/15 15/240 43.75 87.50

176 1 0 1 1 0 0 0 0 0 1 0 0 1 1 1 1 11/15 0 44.00 88.00177 1 0 1 1 0 0 0 1 0 1 0 0 1 1 1 0 11/15 1/240 44.25 88.50178 1 0 1 1 0 0 1 0 0 1 0 0 1 1 0 1 11/15 2/240 44.50 89.00179 1 0 1 1 0 0 1 1 0 1 0 0 1 1 0 0 11/15 3/240 44.75 89.50180 1 0 1 1 0 1 0 0 0 1 0 0 1 0 1 1 11/15 4/240 45.00 90.00181 1 0 1 1 0 1 0 1 0 1 0 0 1 0 1 0 11/15 5/240 45.25 90.50182 1 0 1 1 0 1 1 0 0 1 0 0 1 0 0 1 11/15 6/240 45.50 91.00183 1 0 1 1 0 1 1 1 0 1 0 0 1 0 0 0 11/15 7/240 45.75 91.50184 1 0 1 1 1 0 0 0 0 1 0 0 0 1 1 1 11/15 8/240 46.00 92.00185 1 0 1 1 1 0 0 1 0 1 0 0 0 1 1 0 11/15 9/240 46.25 92.50186 1 0 1 1 1 0 1 0 0 1 0 0 0 1 0 1 11/15 10/240 46.50 93.00187 1 0 1 1 1 0 1 1 0 1 0 0 0 1 0 0 11/15 11/240 46.75 93.50188 1 0 1 1 1 1 0 0 0 1 0 0 0 0 1 1 11/15 12/240 47.00 94.00189 1 0 1 1 1 1 0 1 0 1 0 0 0 0 1 0 11/15 13/240 47.25 94.50190 1 0 1 1 1 1 1 0 0 1 0 0 0 0 0 1 11/15 14/240 47.50 95.00191 1 0 1 1 1 1 1 1 0 1 0 0 0 0 0 0 11/15 15/240 47.75 95.50

Cascading Truth Table (Continued)Normally Closed Solenoids Normally Open SolenoidsDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveBinary Input *

8 4 2 1 8 4 2 1Binary Input *

8 4 2 1 8 4 2 1 Proportion Proportion PSIG Output PSIG OutputStep PIN Number †

5 3 2 1 5 3 2 1PIN Number †

5 3 2 1 5 3 2 1of Inlet

Pressureof Inlet

Pressure@ 60 PSIG

Inlet †† Inlet ††

@ 120 PSIG+

PAR™-15 Valve V-630CP

7

192 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 1 12/15 0 48.00 96.00193 1 1 0 0 0 0 0 1 0 0 1 1 1 1 1 0 12/15 1/240 48.25 96.50194 1 1 0 0 0 0 1 0 0 0 1 1 1 1 0 1 12/15 2/240 48.50 97.00195 1 1 0 0 0 0 1 1 0 0 1 1 1 1 0 0 12/15 3/240 48.75 97.50196 1 1 0 0 0 1 0 0 0 0 1 1 1 0 1 1 12/15 4/240 49.00 98.00197 1 1 0 0 0 1 0 1 0 0 1 1 1 0 1 0 12/15 5/240 49.25 98.50198 1 1 0 0 0 1 1 0 0 0 1 1 1 0 0 1 12/15 6/240 49.50 99.00199 1 1 0 0 0 1 1 1 0 0 1 1 1 0 0 0 12/15 7/240 49.75 99.50200 1 1 0 0 1 0 0 0 0 0 1 1 0 1 1 1 12/15 8/240 50.00 100.00201 1 1 0 0 1 0 0 1 0 0 1 1 0 1 1 0 12/15 9/240 50.25 100.50202 1 1 0 0 1 0 1 0 0 0 1 1 0 1 0 1 12/15 10/240 50.50 101.00203 1 1 0 0 1 0 1 1 0 0 1 1 0 1 0 0 12/15 11/240 50.75 101.50204 1 1 0 0 1 1 0 0 0 0 1 1 0 0 1 1 12/15 12/240 51.00 102.00205 1 1 0 0 1 1 0 1 0 0 1 1 0 0 1 0 12/15 13/240 51.25 102.50206 1 1 0 0 1 1 1 0 0 0 1 1 0 0 0 1 12/15 14/240 51.50 103.00207 1 1 0 0 1 1 1 1 0 0 1 1 0 0 0 0 12/15 15/240 51.75 103.50

208 1 1 0 1 0 0 0 0 0 0 1 0 1 1 1 1 13/15 0 52.00 104.00209 1 1 0 1 0 0 0 1 0 0 1 0 1 1 1 0 13/15 1/240 52.25 104.50210 1 1 0 1 0 0 1 0 0 0 1 0 1 1 0 1 13/15 2/240 52.50 105.00211 1 1 0 1 0 0 1 1 0 0 1 0 1 1 0 0 13/15 3/240 52.75 105.50212 1 1 0 1 0 1 0 0 0 0 1 0 1 0 1 1 13/15 4/240 53.00 106.00213 1 1 0 1 0 1 0 1 0 0 1 0 1 0 1 0 13/15 5/240 53.25 106.50214 1 1 0 1 0 1 1 0 0 0 1 0 1 0 0 1 13/15 6/240 53.50 107.00215 1 1 0 1 0 1 1 1 0 0 1 0 1 0 0 0 13/15 7/240 53.75 107.50216 1 1 0 1 1 0 0 0 0 0 1 0 0 1 1 1 13/15 8/240 54.00 108.00217 1 1 0 1 1 0 0 1 0 0 1 0 0 1 1 0 13/15 9/240 54.25 108.50218 1 1 0 1 1 0 1 0 0 0 1 0 0 1 0 1 13/15 10/240 54.50 109.00219 1 1 0 1 1 0 1 1 0 0 1 0 0 1 0 0 13/15 11/240 54.75 109.50220 1 1 0 1 1 1 0 0 0 0 1 0 0 0 1 1 13/15 12/240 55.00 110.00221 1 1 0 1 1 1 0 1 0 0 1 0 0 0 1 0 13/15 13/240 55.25 110.50222 1 1 0 1 1 1 1 0 0 0 1 0 0 0 0 1 13/15 14/240 55.50 111.00223 1 1 0 1 1 1 1 1 0 0 1 0 0 0 0 0 13/15 15/240 55.75 111.50

224 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 1 14/15 0 56.00 112.00225 1 1 1 0 0 0 0 1 0 0 0 1 1 1 1 0 14/15 1/240 56.25 112.50226 1 1 1 0 0 0 1 0 0 0 0 1 1 1 0 1 14/15 2/240 56.50 113.00227 1 1 1 0 0 0 1 1 0 0 0 1 1 1 0 0 14/15 3/240 56.75 113.50228 1 1 1 0 0 1 0 0 0 0 0 1 1 0 1 1 14/15 4/240 57.00 114.00229 1 1 1 0 0 1 0 1 0 0 0 1 1 0 1 0 14/15 5/240 57.25 114.50230 1 1 1 0 0 1 1 0 0 0 0 1 1 0 0 1 14/15 6/240 57.50 115.00231 1 1 1 0 0 1 1 1 0 0 0 1 1 0 0 0 14/15 7/240 57.75 115.50232 1 1 1 0 1 0 0 0 0 0 0 1 0 1 1 1 14/15 8/240 58.00 116.00233 1 1 1 0 1 0 0 1 0 0 0 1 0 1 1 0 14/15 9/240 58.25 116.50234 1 1 1 0 1 0 1 0 0 0 0 1 0 1 0 1 14/15 10/240 58.50 117.00235 1 1 1 0 1 0 1 1 0 0 0 1 0 1 0 0 14/15 11/240 58.75 117.50236 1 1 1 0 1 1 0 0 0 0 0 1 0 0 1 1 14/15 12/240 59.00 118.00237 1 1 1 0 1 1 0 1 0 0 0 1 0 0 1 0 14/15 13/240 59.25 118.50238 1 1 1 0 1 1 1 0 0 0 0 1 0 0 0 1 14/15 14/240 59.50 119.00239 1 1 1 0 1 1 1 1 0 0 0 1 0 0 0 0 14/15 15/240 59.75 119.50

240 1 1 1 1 0 0 0 0 0 0 0 0 1 1 1 1 15/15 0 60.00 120.00

Table above illustrates available output pressures for inlet pressures of 75 PSIG and 90 PSIG. Inlet pressure may be any value between15 and 150 PSIG. Output pressure increment will be 1/15 of inlet pressure.*0 = Voltage “OFF”1 = Voltage “ON”

† Available only on units with 6-Pin connector.†† Shaded output pressures shown are theoretical and are below the minimum operating range of the valve and should not be used.

Please refer to the Engineering Specifications for minimum output.

Cascading Truth Table (Continued)Normally Closed Solenoids Normally Open SolenoidsDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveDownstream

ValveUpstream

ValveBinary Input *

8 4 2 1 8 4 2 1Binary Input *

8 4 2 1 8 4 2 1 Proportion Proportion PSIG Output PSIG OutputStep PIN Number †

5 3 2 1 5 3 2 1PIN Number †

5 3 2 1 5 3 2 1of Inlet

Pressureof Inlet

Pressure@ 60 PSIG

Inlet †† Inlet ††

@ 120 PSIG+

PAR™-15 Valve V-630CP

8

! WARNINGTo avoid unpredictable system behavior that can cause personalinjury and property damage:

• Disconnect electrical supply (when necessary) before installation,servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected tothis product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is belowfreezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must beperformed by knowledgeable personnel who understand howpneumatic products are to be applied.

• After installation, servicing, or conversion, air and electricalsupplies (when necessary) should be connected and the producttested for proper function and leakage. If audible leakage is present,or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be coveredby paint, etc. If masking is not possible, contact your localrepresentative for replacement labels.

! WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OFTHE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN ORRELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY ANDPROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation,its subsidiaries and authorized distributors provide product and/orsystem options for further investigation by users having technicalexpertise. It is important that you analyze all aspects of your application,including consequences of any failure and review the informationconcerning the product or systems in the current product catalog. Dueto the variety of operating conditions and applications for these productsor systems, the user, through its own analysis and testing, is solelyresponsible for making the final selection of the products and systemsand assuring that all performance, safety and warning requirementsof the application are met.The products described herein, including without limitation, productfeatures, specifications, designs, availability and pricing, are subjectto change by Parker Hannifin Corporation and its subsidiaries at anytime without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FORINCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZETHESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Pneumatic DivisionRichland, Michigan 49083

Pneumatic

Service Instructions: V-631P

PAR™-15 Regulating Valve

ISSUED: November, 2001Supersedes: August, 1999

ECN# 28397

Introduction:Follow these instructions when installing, operating, or servicingthe product.

Application Limits:Operating Pressure Range:

kPa psig barMaximum Inlet 1034 150 10.34Minimum Output 42 6 0.4

Ambient Temperature Range: 0°C to 60°C (32°F to 140°F)Voltage Range: +10 to -10% of Rating

Service Instructions:Disassembly:1. Loosen two Phillips head screws located on top of black

electrical enclosure and remove enclosure from valve (unitswith enclosure only with or without lamps).

2. Remove green lead wire by unscrewing green coloredground screw.

3. Remove wire leads from the four solenoids by sliding theflag receptacles off the solenoid tabs.

4. Remove and set aside the four #10-32 socket head capscrews located at each of the four corners of the valve.

NOTE: Do not remove the #10-32 screws found in the center ofthe valve at this time.

5. Separate top assembly unit from body. This unit will includethe four solenoids, two manifold blocks, adaptor plate,stepped divider, and black piston.

6. Remove and set aside remaining two #10-32 socket headcap screws mentioned in step 4.

7. Separate top assembly into three sub-assembles:a. Solenoid sub-assembly including two manifold bars.b. Adaptor plate.c. Piston and divider sub-assembly.

Solenoid Sub-Assembly –Disassembly and Assembly1. Loosen all four brass screws from manifold block until

manifold separates from solenoids.2. Remove each brass screw from the manifold block

to replace the washer (item #1) and the two o-rings(item #2).

3. Lightly grease the two o-rings and replace the screw inthe bore. Be sure the threaded end of the screw is on thecounterbore side of the manifold block.

4. If replacing solenoids go to step 5, if not go to step 10.5. Remove the two screws holding each solenoid assembly

in place.6. Remove the existing coil, o-ring and plunger.7. Replace with new solenoid assembly. Make sure new

o-ring remains in o-ring groove located on bottom of coil,during assembly.

8. Replace two screws and tighten 0.8 to 1.1 Nm (7 to 10in-lbs).

9. Repeat steps 5 through 8 for each solenoid assembly.10. Replace upper manifold bar, screwing the four brass screws

into the end of each of four solenoids, and tighten to 60 to80 in-oz.

! CAUTION: Be sure the surface with the threadedhole on the manifold block is facing same directionas engraved numbers 1, 2, 4 and 8 on oppositemanifold block.

Adaptor Plate Sub-Assembly – Disassembly1. Remove and replace six small o-rings (item #3) and two

large o-rings (item #4).2. Remove rubber gasket (item #5) and any remaining

adhesive on adaptor plate.3. Peel paper off back of new gasket and place gasket on

adaptor plate, adhesive side down.

PAR™-15 Regulating Valve V-631P

Piston and Divider Sub-Assembly –Disassembly and Assembly1. Remove black piston (item #6) from stepped divider.2. Remove and replace seven o-rings on divider (items #7

through #12).3. Lightly grease (in kit) new o-rings on divider and inside

diameters of new piston (item #6)4. Slide piston over divider, being careful not to let o-rings

roll out of the o-ring grooves.5. Remove and replace six o-rings (item #3), and one rubber

washer (item #13) on top surface of divider. Note thelocation of the rubber washer for either internal or externalpilot supply air, refer to diagram for correct placement.

Top Half Sub-Assembly – Assembly1. Place solenoid sub-assembly on adaptor plate surface

with o-rings. Make sure manifold bar with engravednumbers 1, 2, 4 and 8 is placed over group of five smallo-rings (item #3) on adaptor plate. Align these twosub-assemblies using two #10-32 socket head cap screwslocated in the center of the solenoid sub-assembly.

2. Locate group of five small o-rings on top surface of dividerunder engraved numbers on manifold block as in step 1.Align and attach divider to adaptor plate and solenoidassembly using the two #10-32 screws.

3. Tighten two #10-32 socket head cap screws 3.9 to 4.5Nm (35 to 40 in-lbs).

Bottom Plate – Disassembly and AssemblyIf you have access to the bottom plate and have a specialrepair tool (part number K352412), the poppet and relatedparts can be replaced without removing the valve from itsapplication. Otherwise, it will be necessary to repair the valveat a workbench. In either case, the special repair tool will be avaluable aid.1. Remove bottom plate by removing the three 1/4 - 20 socket

head cap screws.2. Remove poppet guide (item #18), poppet (item #15), and

spring by gripping the inside diameter of the poppet withan expanding tool (such as snap ring pliers) and pull outparts. If you have the special repair tool, depress thehandle button, insert tool fully into inside diameter ofpoppet, release button, and withdraw tool.

3. Place new washer (item #19) on new poppet (item #15).4. Install o-ring (item #14) and quad ring (item # 21) on new

poppet (item #15). Verify that quad ring is not rolled ortwisted in its groove.

5. Install large o-ring (item #16) on new poppet guide (item#18).

6. Lightly grease inside diameter of poppet guide and thetwo seals on this new poppet using the grease provided inthe repair kit.

7. If you do not have the special repair tool:a. Place valve body on workbench with bottom side of

valve facing up.b. Place new poppet with washer in center of 2 inch

bore with rubber side down.c. Place new spring (item #20) on poppet.d. Slide poppet guide into 2 inch bore until flush with

valve body.e. Replace o-ring seal (item #17) on bottom surface.f. Replace bottom plate and tighten three 1/4-20 socket

head cap screws 7.9 to 8.4 Nm (70 to 75 in-lbs).

8. If you have the special repair tool:a. Depress the handle button and stack the new poppet

guide, spring, washer, and poppet onto the tool shankand release the button. Confirm that the poppet willstroke fully by squeezing the poppet and poppet guidetogether and observing that the small end of thepoppet is flush with the end of the poppet guide. If notflush, remove and re-assemble parts.

b. Grasp the tool by the T-handle and insert parts intobody until poppet guide is flush with the body.

c. Depress handle button and withdraw tool.d. Replace o-ring seal (item #17) on bottom surface. If

the valve is mounted vertically, use grease to hold theo-ring in place.

Top Assembly Replacement1. Turn valve over so bottom plate is resting on workbench.2. Put top assembly back on valve body using four #10-32

socket head cap screws to align top assembly to body. Becareful not to roll o-rings out of o-ring grooves on divider.

3. Torque four #10-32 socket head cap screws 3.9 to 4.5 Nm(35 to 40 in-lbs.)

Electrical and Enclosure Assembly(For units with enclosure without lamps)1. Reattach electrical lead wires to solenoids in the following

orientation: one white lead to each of the four solenoids,the red lead wire to solenoid 8, the black lead wire tosolenoid 4, the blue lead wire to solenoid 2, and theorange lead wire to solenoid 1.

2. Reattach green lead wire to manifold block using greenslotted screw.

3. Return electrical enclosure to valve and tighten two Phillipshead screws 0.6 to 1.1 Nm (5 to 10 in-lbs). to secureenclosure to gasket.

Lamp Replacement Instructions:The following instructions are used when replacing one ormore lamps:1. Remove enclosure as described in Disassembly, steps 1

through 3.2. Unscrew wire nut from white lead wiring harness, white

lead from multi-pin connector, and lamp leads (black for120/60 or white for 24VDC). Twist bundle of leads to loosen.

3. Snap open splice connector and pry clip out of splice.Slide lamp lead out of the “blind” side of the spliceconnector, leaving splice connector on lead from multi-pinconnector.

4. Using needle nose pliers press together tangs on thespring clip holding the lamp to the enclosure. Slide springclip off lamp body and lamp leads.

5. Gently pry up lamp and remove from enclosure. Discardlamp and spring clip.

6. Install replacement lamp into enclosure, pressing firmlyto seat.

7. With needle nose pliers depress tangs on the spring clipand slip over lamp leads and down onto lamp body untilfirmly contacting enclosure. Lamp should not be loose.

8. Slide unstripped lamp lead (black for 120/60 or red for24VDC) into “blind” side of splice connector. Replace clipand press flush with top of splice. Snap housing shut.

9. Twist stripped lamp leads, white lead from multi-pinconnector and white lead from wiring harness togetherand cap with wire nut. Screw wire nut down until all leadsare secured and covered.

PAR™-15 Regulating Valve V-631P

10. Reattach electrical lead wires to solenoids as follows: onewhite lead to each of the four solenoids from the wiringharness, the red lead wire to solenoid 8, black lead wireto solenoid 4, the blue lead wire to solenoid 2, and theorange lead wire to solenoid 1.

11. Reattach green lead wire to manifold block using greenslotted screw. See wiring diagrams to assist in reconnectingwiring.

12. Reassemble enclosure in reverse order of assembly.Ensure that all leads are not in a position to be pinched byenclosure. Orient multi-pin connector while looking downfrom the top 90° clockwise from the inlet port. This is thequadrant 2-Position.

For units with DC solenoids and indicator lamps red wire is (+)positive white wire is (-) negative.

! CAUTION: DC solenoids with indicator lamps are polaritysensitive. Observe polarities indicated above.

NOTE: In addition to the above instructions, follow all requirementsfor local and national electrical codes.

Quadrant 2

Inlet Port

Available Lamps:

Description Part NumberLamp (120/60 AC) with spring clip ............................ K352428Lamp (24VDC) with spring clip ................................. K352429

Wiring Diagrams:

L1

L2

L4

L8

WHT(-)

WHT(-)

WHT(-)

WHT(-)RED(+)

RED(+)

RED(+)

RED(+)SOL 1

SOL 2

SOL 4

SOL 8

WHT(-)

RED(+)

GRN

ORG(+)

BLK(+)

BLU(+)

12

3

4 5

6

L1

L2

L4

L8

BLK

BLK

BLK

BLKBLK

BLK

BLK

BLKSOL 1

SOL 2

SOL 4

SOL 8

WHT

RED

GRN

ORG

BLK

BLU

12

3

4 5

6

24VDC

120V/60Hz

White LeadOn WiringHarness

WiringHarness

White LeadFrom Multi-Pin Connector

LampLead

Flag ReceptacleFor Solenoids

Wirenut Ground

Lamp

SpringClip

SpliceConnector

Multi-Pin Connector

PAR™-15 Regulating Valve V-631P

Service Kit:The following components are included in the service kitK352413, please identify all items at this point.

X2CX1

EXH

12

11

6

1514

5

2

1

13

3

3

4

10

9

8

7

19

16 18 2117

20

Section B-B

Section C-C

Section A-A

B BA A

C

C

Install Rubber Isolation PlugHere For Normally Closed Versions

Solenoid

LowerManifoldBar

FlagReceptacle

UpperManifoldBar

(4) Corner#10-32 Screws

(3) 1/4-20Soc Hd CapScrews

(4) Brass Screws

Adaptor Plate

Install Rubber Isolation Plug Here For Normally Open Versions

Divider

Item Qty Description

1 4 Washer

2 8 .176 ID x .070 W O-ring

3 12 .245 ID x .070 W O-ring

4 2 1.301 ID x .070 W O-ring

5 1 Gasket

6 1 Piston

7 1 .551 ID x .070 W O-ring

8 1 1.051 ID x .070 W O-ring

9 1 1.239 ID x .070 W O-ring

10 1 2.175 ID x .103 W O-ring

11 1 2.550 ID x .103 W O-ring

12 2 2.864 ID x .070 W O-ring

13 1 Rubber Plug

14* 1 .926 ID x .070 W O-ring

15* 1 Molded Poppet

16* 1 1.799 ID x .103 W O-ring

17* 1 2.739 ID x .070 W O-ring

18* 1 Poppet Guide

19* 1 Washer

20* 1 Spring

21* 1 .551 ID x .070 W Quad Ring

22* 1 Tube of Grease

Item Qty Description

* Components included in kit K352414

Application LimitsThese products are intended for use in general purpose compressedair systems only.

Operating Pressure Range: kPa psig barMinimum (CN/BW Series)* 172 25 1.72Minimum (W215 Series)* 103 15 1.03Maximum (CN/BW Series 414 60 4.14

1.2 Watt Operator)Maximum (CN Series all others) 689 100 6.89Maximum (W215 Series) 1034 150 10.34

* These values are minimum shift pressures for the valves piloted.

Operating Temperature Range:Minimum 0°C (32°F)Maximum (CN/BW Series)* 52°C (125°F)Maximum (W215 Series)* 60°C (140°F)

* These values are based on maximum recommended temperatures for thevalves piloted.

Voltage Range: +10%, -15% of Rating

SOLENOID

PRYSLOT (EQUIPMENT

GROUND)

MINI PLUG

2 1A

B

BCOIL

1"

1/4"C

F

E

D

C

A

F

E

D

FIGURE 1 FIGURE 2 FIGURE 3

Operator Replacement (CN/BW Series)1. Loosen screw holding cable plug to operator and pull off

connector (plug-in style only).2. Remove the two slotted head screws on top of the operator and

retain. Remove and discard operator.3. Place new operator on top of valve and tighten the screws to

112 to 120 in-ozs.(Make certain o-ring and plunger do notdislodge from bottom of operator.)

4. Reconnect cable plug and tighten screw.

3-Pin Female Connector KitFemale connector and gaskets must be ordered as kits. Electriccable for use with 3-Pin connector should have an outside diameterof .236 to .315 in (6 to 8mm).— Without Indicator Light - Kit# PS2429P— With Indicator Light (12V, 60Hz, 12VDC) - Kit# PS243075P— With Indicator Light (24V, 60Hz, 24VDC) - Kit# PS243079P— With Indicator Light (120V, 60Hz) - Kit# PS243083P— With Indicator Light (240V, 60Hz) - Kit# PS243087P

Wiring Instructions for Cable Plug(CN/BW Series)1. Remove the holding screw (A) from the cable plug and pry the

contact holder (B) from the plug case (C). (Figure 1).2. Remove the gland nut (D), thrust washer (E) and gland (F) from

the plug case and slide each part over the multiconductor cablein the order removed. Insert cable through the plug case.(Figure 2)

3. Strip the cable as shown in Figure 2.4. Insert conductors into contacts in contact holder as shown in the

wiring schematic and securely tighten the contact screws toretain the conductors. (Figure 3)

5. Work contact holder back into the plug case and snap it intoplace.

6. Slide the gland, thrust washer and gland nut into the plug case.Tighten the gland nut to provide strain relief for the conductors.

7. Reinsert the holding screw.8. To connect the cable plug to the solenoid operator, push the

plug onto the male terminals and tighten the holding screw.

Note: In addition to above instructions, follow all requirements forlocal and national electrical codes.

Operator Replacement (W215 Series)1. Loosen two phillips pan head screws (A) and remove cover

assembly (B).2. Pull flag receptacles (C) off of operators (H).3. Remove the three socket head cap screws (D) securing the

exhaust manifold (F).4. Loosen the four exhaust adaptors (E) and remove the exhaust

manifold (F).5. Remove the two slotted head screws (G) securing each operator

and retain.6. Remove and discard operator.7. Clean and seat areas in manifold block (J) with mineral spirits or

equivalent cleaning solution.8. Assemble new operators to manifold block (J) and tighten the

screws to 7 to 10 in-lbs (make certain o-ring and plunger do notdislodge from bottom of operator.)

9. Place exhaust manifold (F) on top of plate, align exhaustadaptors (E) and screw each in 2 to 4 turns. (The four smalldrilled holes must be facing downward.)

Pneumatic Division North AmericaRichland, Michigan 49083

! WARNINGTo avoid unpredictable system behavior that can cause personal injury and propertydamage:

• Disconnect air supply and depressurize all air lines connected to this product beforeinstallation, servicing, or conversion.

• Disconnect electrical supply before installation, servicing, or conversion.• Operate within the manufacturer's specified pressure, temperature, voltage and other

conditions listed in these instructions.• Medium must be moisture-free if ambient temperature is below freezing.• Service according to procedures listed on these instructions.• Installation, service and conversion of these products must be performed by

knowledgeable personnel who understand how pneumatic products are to be applied.• After installation, servicing, or conversion, air and electrical supplies should be connected

and the product tested for proper function and leakage. If audible leakage is present, or theproduct does not operate properly, do not put into use.

• Warnings and specifications on the product should not be covered by paint, etc. If maskingis not possible, contact your local representative for replacement labels.

! WARNINGFAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THEPRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMSCAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, itssubsidiaries and authorized distributors provide product and/or system optionsfor further investigation by users having technical expertise. It is important thatyou analyze all aspects of your application, including consequences of anyfailure, and review the information concerning the product or system in thecurrent product catalog. Due to the variety of operating conditions andapplications for these products or systems, the user, through its own analysisand testing, is solely responsible for making the final selection of the productsand systems and assuring that all performance, safety and warningrequirements of the application are met.

The products described herein, including without limitation, product features,specifications, designs, availability and pricing, are subject to change by ParkerHannifin Corporation and its subsidiaries at any time without notice.

Service Instructions: V-632PReplacement Operators forW215 and CN/BW Series

ISSUED: November, 1998Supersedes: K583-301, June, 1993ECN# 8976

Replacement Operators V-632P

2

10. Reassemble the three socket head cap screws (D) and tighten to35 to 40 in-lbs.

11. Tighten the exhaust adaptors to 30 to 50 in-ozs.12. Refer to the wiring diagram at right and the solenoid numbers

marked on the top of the manifold block (J). Slide the pair of flagreceptacles (C) with the proper colored wires onto the twoparallel tabs on top of each operator (H). The operators are notpolarity sensitive. If unit was purchased without cover and 5-pinplug, refer to Wiring instructions for Cable Plug found on front ofthis sheet.

13. Reassemble the cover assembly (B) and tighten phillips panhead screws (A) 5 to 10 in-lbs.

Wiring Instructions (W215 Series)If unit is equipped with 6-pin male receptacle, convert to femaleconnector (Brad Harrison 42602 or Cam-Lok E2118-625). Wireper following table:

Pin Wire Color Function1 Orange Input 12 Blue Input 23 Black Input 44 White Common5 Red Input 86 Green Equipment

Ground

If unit is not equipped with 6-pin male receptacle, use cable plugs orother similar wiring devices approved by local and national electricalcodes. Wire each solenoid operator per Wiring Instructions for CablePlug found on front of this sheet. Solenoid operator numbers arefound on top of the manifold block (J).

Note: In addition to above instructions, follow all requirements forlocal and national electrical codes.

X2CX1

JH

A

D

E

F

G

B C

With Lamps

L1

L2

L4

L8

WHT(-)

WHT(-)

WHT(-)

WHT(-)RED(+)

RED(+)

RED(+)

RED(+)SOL 1

SOL 2

SOL 4

SOL 8

WHT(-)

RED(+)

GRN

ORG(+)

BLK(+)

BLU(+)

12

3

4 5

6

L1

L2

L4

L8

BLK

BLK

BLK

BLKBLK

BLK

BLK

BLKSOL 1

SOL 2

SOL 4

SOL 8

WHT

RED

GRN

ORG

BLK

BLU

12

3

4 5

6

Caution: DC solenoids with indicator lamps are polaritysensitive. Observe polarities indicated.

Without Lamps

GND

ORN

BLU

SOL 1

SOL 2

GRN

WH

ITE

WH

WHWH

WH

BLK SOL 4

RED SOL 8

Replacement OperatorsVoltage/Hertz

OperatorNormallyClosedPlug-in

OperatorNormallyClosed18” Leads

OperatorNormallyClosed72” Leads

OperatorNormallyOpenPlug-In †

24V/60Hz H172 150 — — H172 155120V/60Hz110V/60Hz

H172 146 H172 161 H172 162 H172 151

240V/60Hz220V/50Hz

H172 149 — — H172 154

12VDC H172 147 — — H172 15224VDC H172 148 H172 159 H172 160 H172 15324VDC(1.2W)

H172 156 — — —

120VDC H172 157 — — H172 158

† Used only with W215 Series.

1

2

3

4

56

1. Depress button and stack parts onto tool as shown.2. Release button to capture parts.3. Depress button to release parts.

FOR FULL SERVICE INSTRUCTIONS SEE V-631P.

BUTTON

! WARNING

To avoid unpredictable system behavior that can cause personal injuryand property damage:

• Disconnect air supply and depressurize all air lines connected to thisproduct before installation, servicing, or conversion.

• Disconnect electrical supply before installation, servicing orconversion.

• Operate within the manufacturer's specified pressure, temperature,voltage and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is belowfreezing.

• Service according to procedures listed on service instructions sheets.• Installation, service and conversion of these products must be

performed by knowledgeable personnel who understand howpneumatic products are to be applied.

• After installation, servicing, or conversion, air and electrical suppliesshould be connected and the product tested for proper function andleakage. If audible leakage is present, or the product does not operateproperly, do not put into use.

• Warnings and specifications on the product should not be covered bypaint, etc. If masking is not possible, contact your local representativefor replacement labels.

Instructions: V-633PRepair Tool K352412 for PAR-15 Valve

ISSUED: November, 1998

SUPERSEDES: K583424, July, 1997ECN #8976

Pneumatic Division North America8676 East M-89Richland, MI 49083

V-633P

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT / MAINTENANCEINSTRUCTION MANUALS THAT UTILIZE THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

WARNING!FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATEDITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system optionsfor further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of anyfailure, and review the information concerning the product or system in the current product catalog. Due to the variety of operating conditions andapplications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of theproducts and systems and assuring that all performance, safety and warning requirements of the application are met.

The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change byParker Hannifin Corporation and its subsidiaries at any time without notice.

! WARNINGTo avoid unpredictable system behavior that can cause personal injuryand property damage:

• Disconnect electrical supply (when necessary) before installation,servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected tothis product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is belowfreezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must beperformed by knowledgeable personnel who understand howpneumatic products are to be applied.

• After installation, servicing, or conversion, air and electricalsupplies (when necessary) should be connected and the producttested for proper function and leakage. If audible leakage is present,or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be coveredby paint, etc. If masking is not possible, contact your localrepresentative for replacement labels.

! WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OFTHE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN ORRELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY ANDPROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation,its subsidiaries and authorized distributors provide product and/orsystem options for further investigation by users having technicalexpertise. It is important that you analyze all aspects of your application,including consequences of any failure and review the informationconcerning the product or systems in the current product catalog. Dueto the variety of operating conditions and applications for these productsor systems, the user, through its own analysis and testing, is solelyresponsible for making the final selection of the products and systemsand assuring that all performance, safety and warning requirementsof the application are met.The products described herein, including without limitation, productfeatures, specifications, designs, availability and pricing, are subjectto change by Parker Hannifin Corporation and its subsidiaries at anytime without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FORINCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZETHESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Pneumatic DivisionRichland, Michigan 49083

Pneumatic

Service Instructions: V-634BP

PAR™-15 Regulating Valve withTelepneumatic Solenoids

ISSUED: August, 2002Supersedes: November, 2001Doc. # V-634P, ECN# 020330, Rev.2

Introduction:Follow these instructions when installing, operating, or servicingthe product.

Application Limits:Operating Pressure Range:

kPa psig barMaximum Inlet 1034 150 10.34Minimum Output 42 6 0.4

Ambient Temperature Range: 0°C to 60°C (32°F to 140°F)Voltage Range: +10 to -10% of Rating

Service Instructions:Disassembly:1. Loosen two Phillips head screws located on top of black

electrical enclosure and remove enclosure from valve (unitswith enclosure only with or without lamps).

2. Remove green lead wire by unscrewing green coloredground screw.

3. Remove wire leads from both terminal blocks by looseningthe wire crimp screws and removing the wires.

4. Remove and set aside the four #10-32 socket head capscrews located at each of the four corners of the valve.

NOTE: Do not remove the #10-32 screws found in the center ofthe valve at this time.

5. Separate top assembly unit from body. This unit will includethe four solenoids, circuit board, adaptor plate, steppeddivider, and black piston.

6. Remove the circuit board from the two solenoids byremoving the two #6-32 screws and lifting the circuit boardoff.

7. Remove the four solenoids by loosening the two screwson each solenoid.

8. Remove and set aside remaining two #10-32 socket headcap screws mentioned in step #4.

9. Separate top assembly into three sub-assembles:a. Four solenoids.b. Adaptor plate.c. Piston and divider sub-assembly.

Adaptor Plate Sub-Assembly – Disassembly1. Remove and replace four gaskets (item #1).2. Remove rubber gasket (item #3) and any remaining

adhesive on adaptor plate.3. Peel paper off back of new gasket and place gasket on

adaptor plate, adhesive side down.

Piston and Divider Sub-Assembly –Disassembly and Assembly1. Remove black piston (item #4) from stepped divider.2. Remove and replace seven o-rings on divider (items #5

through #10).3. Lightly grease (in kit) new o-rings on divider and inside

diameters of new piston (item #4)4. Slide piston over divider, being careful not to let o-rings

roll out of the o-ring grooves.5. Remove and replace six o-rings (item #2), and one rubber

washer (item #11) on top surface of divider. Note thelocation of the rubber washer for either internal or externalpilot supply air, refer to diagram for correct placement.

Top Half Sub-Assembly – Assembly1. Align and attach divider to adapter plate using the center

two #10-32 socket head cap screws 3.9 to 4.5Nm (35 to40 in-lb). The short screw is to be used in the counterboredhole.

2. Attach each of the four solenoids on the adapter platewith the original screws provided. Orient the solenoidswith the pins away from you while reading the 1, 2, 8, 4engraving.

PAR™-15 Regulating Valve with Telepneumatic Solenoids V-634BP3. Align circuit board with the solenoid terminals. Attach the

two #6-32 screws to the side of the circuit board throughthe spacer and into the adapter plate.

Bottom Plate – Disassembly and AssemblyIf you have access to the bottom plate and have a specialrepair tool (part number K352412), the poppet and relatedparts can be replaced without removing the valve from itsapplication. Otherwise, it will be necessary to repair the valveat a workbench. In either case, the special repair tool will be avaluable aid.1. Remove bottom plate by removing the three 1/4 - 20 socket

head cap screws.2. Remove poppet guide (item #16), poppet (item #13), and

spring (item #18) by gripping the inside diameter of thepoppet with an expanding tool (such as snap ring pliers)and pull out parts. If you have the special repair tool,depress the handle button, insert tool fully into insidediameter of poppet, release button, and withdraw tool.

3. Place new washer (item #17) on new poppet (item #13).4. Install new o-ring (item #12) and quad ring (item # 19) on

new poppet (item #13). Verify that quad ring is not rolledor twisted in its groove.

5. Install large o-ring (item #14) on new poppet guide (item#16).

6. Lightly grease inside diameter of poppet guide and thetwo seals on this new poppet using the grease provided inthe repair kit.

7. If you do not have the special repair tool:a. Place valve body on workbench with bottom side of

valve facing up.b. Place new poppet with washer in center of 2 inch

bore with rubber side down.c. Place new spring (item #18) on poppet.d. Slide poppet guide into 2 inch bore until flush with

valve body.e. Replace o-ring seal (item #15) on bottom surface. If

the valve is mounted vertically, use grease to holdthe o-ring in place.

f. Replace bottom plate and tighten three 1/4-20 sockethead cap screws 7.9 to 8.4Nm (70 to 75 in-lb).

8. If you have the special repair tool:a. Depress the handle button and stack the new poppet

guide, spring, washer, and poppet onto the tool shankand release the button. Confirm that the poppet willstroke fully by squeezing the poppet and poppet guidetogether and observing that the small end of thepoppet is flush with the end of the poppet guide. If notflush, remove and re-assemble parts.

b. Grasp the tool by the T-handle and insert parts intobody until poppet guide is flush with the body.

c. Depress handle button and withdraw tool.d. Replace o-ring seal (item #15) on bottom surface. If

the valve is mounted vertically, use grease to holdthe o-ring in place.

e. Replace the bottom plate and tighten three 1/4-20socket head cap screws 7.9 to 8.4Nm (70 to75 in-lb.)

Top Assembly Replacement1. Turn valve over so bottom plate is resting on workbench.2. Put top assembly back on valve body using four #10-32

socket head cap screws to align top assembly to body. Becareful not to roll o-rings out of o-ring grooves on divider.

3. Torque four #10-32 socket head cap screws 3.9 to 4.5Nm(35 to 40 in-lb.)

Electrical and Enclosure Assembly (See WiringDiagram)(For units with enclosure without lamps)1A. With mini receptacle -

Reattach electrical lead wires to terminal block TB1 in thefollowing orientation: the white lead wire to the “C” terminal,the red lead wire to the “8” terminal, the black lead wire tothe “4” terminal, the blue lead wire to the “2”, and theorange lead wire to the “1” terminal.

1B. With micro receptacle -Reattach electrical lead wires to terminal block TB1 in thefollowing orientation: the red/yellow lead wire to the “C”terminal, the red/black lead wire to the “8” terminal, thered/blue lead wire to the “4” terminal, the red lead wire tothe “2”, and the red/white lead wire to the “1” terminal.

2. Reattach green lead wire to manifold block using greenslotted screw.

3. Return electrical enclosure to valve and tighten two Phillipshead screws 0.6 to 1.1Nm (5 to 10 in-lb) to secureenclosure to adapter plate.

Lamp Replacement Instructions (See WiringDiagram)The following instructions are used when replacing one ormore lamps:1. Remove enclosure as described in Disassembly, step 1.2. Remove the two lamp lead wires (red and white for 24VDC

or black and black for 120/60) from the terminal blockTB2.

3. Using needle nose pliers press together tangs on thespring clip holding the lamp to the enclosure. Slide springclip off lamp body and lamp leads.

4. Gently pry up lamp and remove from enclosure. Discardlamp and spring clip.

5. Install replacement lamp into enclosure, pressing firmlyto seat.

6. With needle nose pliers depress tangs on the spring clipand slip over lamp leads and down onto lamp body untilfirmly contacting enclosure. Lamp should not be loose.

7. Insert stripped lamp leads (red and white for 24VDC orblack and black for 120/60) into terminal block TB2(red = (+) and white = (-) for 24VDC).

8. Reassemble enclosure in reverse order of assembly.Ensure that all leads are not in a position to be pinchedby enclosure. Orient multi-pin receptacle while lookingdown from the top either 90° clockwise or 90°counterclockwise from the inlet port. This is the quadrant2 and quadrant 4 position respectively.

For units with DC solenoids and indicator lamps red wire is (+)positive, white wire is (-) negative.

! CAUTION: DC solenoids with indicator lamps are polaritysensitive. Observe polarities indicated above.

NOTE: In addition to the above instructions, follow all requirementsfor local and national electrical codes.

Quadrant 4

Inlet Port

Quadrant 2

180˚

PAR™-15 Regulating Valve with Telepneumatic Solenoids V-634BPAvailable Lamps:

Description Part NumberLamp (120/60 AC) with spring clip ........................ K352428CLamp (24VDC) with spring clip ............................. K352429C

Wiring Diagrams:

RED

WHTGRN

SOL 4

ORG

3 64

BLU

BLK

SOL 8

COM

SOL 2

SOL 1

4

RED

BLACK

RED

8

C

2

1 1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

BLACK

RED

BLACK

BLACK

RED

RED-BLU

RED-BLK

RED

GREENRED-YEL

GRN

SOL 4

RED-WHT

3

2 1

5

2 1

5

2 1

5

64

BLU

SOL 8

COM

SOL 2

SOL 1

4

RED

BLACK

RED

8

C

2

1

BLACK

RED

BLACK

BLACK

RED

RED

WHTGRN

SOL 4

ORG

3 64

BLU

BLK

SOL 8

COM

SOL 2

SOL 1

4

8

C

2

1BLACK

REDBLACK

RED

BLACK

RED

BLACK

RED

BLACK

REDBLACK

RED

BLACK

RED

BLACK

RED

RED-BLU

RED-BLK

RED

GREENRED-YEL

GRN

SOL 4

RED-WHT

3

2 1

56

4

BLU

SOL 8

COM

SOL 2

SOL 1

4

8

C

2

1

120 VAC Mini Connector 120 VAC Micro Connector

24 VDC Mini Connector 24 VDC Micro Connector

L1

L2

L3

L4

(TB2)

(TB1)

CONNECTOR

LIGHTS

1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

L1

L2

L3

L4

(TB2)

(TB1)

LIGHTS

1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

L1

L2

L3

L4

(TB2)

(TB1)

LIGHTS

1 (-)

1 (+)

2 (-)

2 (+)

8 (-)

8 (+)

4 (-)

4 (+)

L1

L2

L3

L4

(TB2)

(TB1)

CONNECTOR

LIGHTS

CONNECTOR

CONNECTOR

PAR™-15 Regulating Valve with Telepneumatic Solenoids V-634BP

Service Kit:The following components are included in the service kitK352413B, please identify all items at this point.

Item Qty Description

1 4 Gasket

2 6 .145 ID x .070 W O-ring

3 1 Gasket

4 1 Piston

5 1 .551 ID x .070 W O-ring

6 1 1.051 ID x .070 W O-ring

7 1 1.239 ID x .070 W O-ring

8 1 2.175 ID x .103 W O-ring

9 1 2.550 ID x .103 W O-ring

10 2 2.864 ID x .070 W O-ring

11 1 Rubber Plug

12* 1 .926 ID x .070 W O-ring

13* 1 Molded Poppet

14* 1 1.799 ID x .103 W O-ring

15* 1 2.739 ID x .070 W O-ring

16* 1 Poppet Guide

17* 1 Washer

18* 1 Spring

19* 1 .551 ID x .070 W Quad Ring

20* 2 Tube of Grease (Not Shown)

Item Qty Description

* Components included in kit K352414

EXH

109

4

1312

3

1

8

7

6

5

17

14 16 1915

18BottomPlate

Section C-C

Section A-A

B B

A A

C

C

Solenoid

Circuit Board

SteppedDivider

Short Screw

(3) 1/4-20Soc Hd CapScrews

12

84

11

2

Section B-B

Install Rubber Isolation PlugHere For Normally Closed Versions

Install Rubber Isolation Plug Here For Normally Open Versions

X1 X2CAdaptor Plate

! WARNINGTo avoid unpredictable system behavior that can cause personalinjury and property damage:

• Disconnect electrical supply (when necessary) before installation,servicing, or conversion.

• Disconnect air supply and depressurize all air lines connected tothis product before installation, servicing, or conversion.

• Operate within the manufacturer’s specified pressure, temperature,and other conditions listed in these instructions.

• Medium must be moisture-free if ambient temperature is belowfreezing.

• Service according to procedures listed in these instructions.

• Installation, service, and conversion of these products must beperformed by knowledgeable personnel who understand howpneumatic products are to be applied.

• After installation, servicing, or conversion, air and electricalsupplies (when necessary) should be connected and the producttested for proper function and leakage. If audible leakage is present,or the product does not operate properly, do not put into use.

• Warnings and specifications on the product should not be coveredby paint, etc. If masking is not possible, contact your localrepresentative for replacement labels.

! WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OFTHE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN ORRELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY ANDPROPERTY DAMAGE.This document and other information from Parker Hannifin Corporation,its subsidiaries and authorized distributors provide product and/orsystem options for further investigation by users having technicalexpertise. It is important that you analyze all aspects of your application,including consequences of any failure and review the informationconcerning the product or systems in the current product catalog. Dueto the variety of operating conditions and applications for these productsor systems, the user, through its own analysis and testing, is solelyresponsible for making the final selection of the products and systemsand assuring that all performance, safety and warning requirementsof the application are met.The products described herein, including without limitation, productfeatures, specifications, designs, availability and pricing, are subjectto change by Parker Hannifin Corporation and its subsidiaries at anytime without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FORINCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZETHESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

Pneumatic Division North AmericaRichland, Michigan 49083

Pneumatic

Conversion Instructions: V-635P

PAR™-15 Regulating ValveLevel “A” Solenoids toLevel “B” Solenoids

ISSUED: December, 2000

REV. 1, NPR 6967

Introduction:Follow these instructions when converting 120V/60Hz normallyopen, old style solenoid operators, to newer designTelepneumatic solenoids. “Mini” connector wiring instructionsare included. Valves with lamps are not covered in thisconversion kit.

Conversion Instructions:Disassembly:1. Remove cover screws located on top of black electrical

enclosure and discard. Remove enclosure from valve.2. Remove green lead wire by unscrewing green colored

ground screw. Discard ground screw.3. Remove wire leads from the four solenoids by sliding the

flag receptacles off the solenoid tabs.NOTE: Flag receptacle are no longer needed.

4. Remove and discard the four #10-32 socket head capscrews located at each of the four corners of the valve.

NOTE: Do not remove the two #10-32 screws found in the centerof the valve at this time.

5. Separate top assembly unit from body. This unit will includethe four solenoids, two manifold blocks, adapter plate,stepped divider, and black piston.

6. Remove and discard remaining two #10-32 socket headcap screws mentioned in step 4.

7. Discard solenoid sub-assembly including two manifold bars,and adapter plate. Set aside piston and divider sub-assembly.

Adapter Plate Sub-Assembly1. Install four gaskets (item #1) (see Section A-A).2. Peel paper off back of gasket (item #3) and place gasket

on adapter plate, adhesive side down.3. Factory installed pipe plugs in ports ‘X2’ and ‘C’ are for

normally open function.

Divider Seals1. Remove and replace six o-rings (item #2), and one rubber

isolation plug (item #17) on top surface of divider. Notethe location of the rubber plug for normally open pilotsupply. Refer to Section B-B for correct placement.

Top Half Sub-Assembly – Assembly1. Align and attach divider to adapter plate using the center

two #10-32 socket head cap screws. The short screw(item #11) is to be used in the counterbored hole. Torquescrews 3.9 to 4.5Nm (35 to 40 in-lb).

2. Put adapter plate assembly back on valve body using four#10-32 socket head cap screws (item #10) to align adapterplate assembly to body. Be careful not to roll o-rings out ofo-ring grooves on divider. Torque screws 3.9 to 4.5Nm (35to 40 in-lb.)

3. Attach each of the four solenoids on the adapter platewith screws (item #6). Torque screws .56 to .70Nm (80 to100 in-oz). Orient the solenoids with the pins away fromyou while reading the 1, 2, 8, 4 engraving.

4. Align circuit board with the solenoid terminals. Attachthe two #6-32 screws (item #8) to the side of the circuitboard through the circuit board spacer (item #7) andinto the adapter plate. Torque screws .68 to .90Nm (96 to128 in-oz).

Electrical and Enclosure Assembly(See Wiring Diagram)1. With mini receptacle -

Attach electrical lead wires to terminal block TB1 in thefollowing orientation: the white lead wire to the “C” terminal,the red lead wire to the “8” terminal, the black lead wire tothe “4” terminal, the blue lead wire to the “2”, and theorange lead wire to the “1” terminal. Replace new wiringdecal (item #15) over old wiring decal inside cover.

2. Attach green lead wire to manifold block using greenslotted screw (item #12). Torque screw 1.1 to 2.3Nm(10 to 20 in-lb).

PAR™-15 Regulating Valve, Level “A” Solenoids to Level “B” Solenoids V-635P

Item Qty Description

1 4 Gasket

2 8 .145 ID x .070 W O-ring

3 1 Gasket

4 1 Circuit Board

5 4 Solenoid Operator

6 8 Screw - Solenoid Operator

7 2 Circuit Board Spacer

8 2 #6-32 x 1-1/4 Long Screw

9 1 Adapter Plate

10 5 #10-32 x 1 Long Screw

11 1 #6-32 x 3/4 Long Screw

12 1 Ground Screw

13 2 #10-32 x 3 Long Screw

14 2 Thread Seal

15 1 Wiring Diagram (120V/60Hz)

16 2 Pipe Plug

17 1 Rubber Isolation Plug

18 1 Instruction Sheet (Not Shown)

Item Qty Description

3. Assemble thread seal (item #14) to #10-32x3" long screws(item #13).

4. Install screws in Electrical Enclosure and apply o-rings(item #2) to ends of screws as shown.

5. Return electrical enclosure to valve and tighten two screws0.6 to 1.1Nm (5 to 10 in-lb) to secure enclosure to adapterplate.

NOTE: In addition to the above instructions, follow all requirementsfor local and national electrical codes.

Conversion Kit:The following components are included in the service kitK322017, please identify all items at this point.

RED

WHTGRN

SOL 4

ORG

3 64

BLU

BLK

SOL 8

COM

SOL 2

SOL 1

4

8

C

2

1

2 1

5

120 VAC Mini Connector

(TB1)

CONNECTOR

3

15

9

5

12

16

4

1

6

Section C-C

Section A-A

B B

A A

C

C

2

1413

Divider

11(ShortScrew)

ElectricalEnclosure

10

12

84 2

Section B-B

17(Install Rubber Isolation Plug Here For Normally Open Versions)

X2X1 C

10

7

8

Wiring Diagram

Pneumatic DivisionRichland, Michigan 49083 269-629-5000

PDNSG-1

Safety Guide For Selecting And Using Pneumatic Division Products And Related AccessoriesWARNING:

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF PNEUMATIC DIVISION PRODUCTS, ASSEMBLIES OR RELATED ITEMS (“PRODUCTS”) CAN CAUSE DEATH, PERSONAL INJURY, AND PROPERTY DAMAGE. POSSIBLE CONSEQUENCES OF FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THESE PRODUCTS INCLUDE BUT ARE NOT LIMITED TO:• Unintended or mistimed cycling or motion of machine members or failure to cycle

• Work pieces or component parts being thrown off at high speeds.

• Failure of a device to function properly for example, failure to clamp or unclamp an associated item or device.

• Explosion

• Suddenly moving or falling objects.

• Release of toxic or otherwise injurious liquids or gasses.

Before selecting or using any of these Products, it is important that you read and follow the instructions below.

1. GENERAL INSTRUCTIONS 1.1. Scope: This safety guide is designed to cover general guidelines on the installation, use, and maintenance of Pneumatic Division

Valves, FRLs (Filters, Pressure Regulators, and Lubricators), Vacuum products and related accessory components. 1.2. Fail-Safe: Valves, FRLs, Vacuum products and their related components can and do fail without warning for many reasons. Design all

systems and equipment in a fail-safe mode, so that failure of associated valves, FRLs or Vacuum products will not endanger persons or property.

1.3 Relevant International Standards: For a good guide to the application of a broad spectrum of pneumatic fluid power devices see: ISO 4414:1998, Pneumatic Fluid Power – General Rules Relating to Systems. See www.iso.org for ordering information.

1.4. Distribution: Provide a copy of this safety guide to each person that is responsible for selection, installation, or use of Valves, FRLs or Vacuum products. Do not select, or use Parker valves, FRLs or vacuum products without thoroughly reading and understanding this safety guide as well as the specific Parker publications for the products considered or selected.

1.5. User Responsibility: Due to the wide variety of operating conditions and applications for valves, FRLs, and vacuum products Parker and its distributors do not represent or warrant that any particular valve, FRL or vacuum product is suitable for any specific end use system. This safety guide does not analyze all technical parameters that must be considered in selecting a product. The user, through its own analysis and testing, is solely responsible for: • Making the final selection of the appropriate valve, FRL, Vacuum component, or accessory.

• Assuring that all user’s performance, endurance, maintenance, safety, and warning requirements are met and that the application presents no health or safety hazards.

• Complying with all existing warning labels and / or providing all appropriate health and safety warnings on the equipment on which the valves, FRLs or Vacuum products are used; and,

• Assuring compliance with all applicable government and industry standards. 1.6. Safety Devices: Safety devices should not be removed, or defeated. 1.7. Warning Labels: Warning labels should not be removed, painted over or otherwise obscured. 1.8. Additional Questions: Call the appropriate Parker technical service department if you have any questions or require any additional

information. See the Parker publication for the product being considered or used, or call 1-800-CPARKER, or go to www.parker.com, for telephone numbers of the appropriate technical service department.

2. PRODUCT SELECTION INSTRUCTIONS 2.1. Flow Rate: The flow rate requirements of a system are frequently the primary consideration when designing any pneumatic system.

System components need to be able to provide adequate flow and pressure for the desired application. 2.2. Pressure Rating: Never exceed the rated pressure of a product. Consult product labeling, Pneumatic Division catalogs or the

instruction sheets supplied for maximum pressure ratings. 2.3. Temperature Rating: Never exceed the temperature rating of a product. Excessive heat can shorten the life expectancy of a product

and result in complete product failure. 2.4. Environment: Many environmental conditions can affect the integrity and suitability of a product for a given application. Pneumatic

Division products are designed for use in general purpose industrial applications. If these products are to be used in unusual circumstances such as direct sunlight and/or corrosive or caustic environments, such use can shorten the useful life and lead to premature failure of a product.

2.5. Lubrication and Compressor Carryover: Some modern synthetic oils can and will attack nitrile seals. If there is any possibility of synthetic oils or greases migrating into the pneumatic components check for compatibility with the seal materials used. Consult the factory or product literature for materials of construction.

2.6. Polycarbonate Bowls and Sight Glasses: To avoid potential polycarbonate bowl failures: • Do not locate polycarbonate bowls or sight glasses in areas where they could be subject to direct sunlight, impact blow, or temperatures outside of the rated range.

• Do not expose or clean polycarbonate bowls with detergents, chlorinated hydro-carbons, keytones, esters or certain alcohols. • Do not use polycarbonate bowls or sight glasses in air systems where compressors are lubricated with fire resistant fluids such as

phosphate ester and di-ester lubricants.

!

PDNSG-1

Pneumatic Division Safety Guide

ISSUED: August 1 , 2006

Supersedes: June 1, 2006

Pneumatic Division Safety Guide

2.7. Chemical Compatibility: For more information on plastic component chemical compatibility see Pneumatic Division technical bulletins Tec-3, Tec-4, and Tec-5

2.8. Product Rupture: Product rupture can cause death, serious personal injury, and property damage. • Do not connect pressure regulators or other Pneumatic Division products to bottled gas cylinders.

• Do not exceed the maximum primary pressure rating of any pressure regulator or any system component. • Consult product labeling or product literature for pressure rating limitations.3. PRODUCT ASSEMBLY AND INSTALLATION INSTRUCTIONS 3.1. Component Inspection: Prior to assembly or installation a careful examination of the valves, FRLs or vacuum products must be

performed. All components must be checked for correct style, size, and catalog number. DO NOT use any component that displays any signs of nonconformance.

3.2. Installation Instructions: Parker published Installation Instructions must be followed for installation of Parker valves, FRLs and vacuum components. These instructions are provided with every Parker valve or FRL sold, or by calling 1-800-CPARKER, or at www.parker.com.

3.3. Air Supply: The air supply or control medium supplied to Valves, FRLs and Vacuum components must be moisture-free if ambient temperature can drop below freezing

4. VALVE AND FRL MAINTENANCE AND REPLACEMENT INSTRUCTIONS 4.1. Maintenance: Even with proper selection and installation, valve, FRL and vacuum products service life may be significantly reduced

without a continuing maintenance program. The severity of the application, risk potential from a component failure, and experience with any known failures in the application or in similar applications should determine the frequency of inspections and the servicing or replacement of Pneumatic Division products so that products are replaced before any failure occurs. A maintenance program must be established and followed by the user and, at minimum, must include instructions 4.2 through 4.10.

4.2. Installation and Service Instructions: Before attempting to service or replace any worn or damaged parts consult the appropriate Service Bulletin for the valve or FRL in question for the appropriate practices to service the unit in question. These Service and Installation Instructions are provided with every Parker valve and FRL sold, or are available by calling 1-800-CPARKER, or by accessing the Parker web site at www.parker.com.

4.3. Lockout / Tagout Procedures: Be sure to follow all required lockout and tagout procedures when servicing equipment. For more information see: OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – (Lockout / Tagout)

4.4. Visual Inspection: Any of the following conditions requires immediate system shut down and replacement of worn or damaged components: • Air leakage: Look and listen to see if there are any signs of visual damage to any of the components in the system. Leakage is an indication of worn or damaged components.

• Damaged or degraded components: Look to see if there are any visible signs of wear or component degradation. • Kinked, crushed, or damaged hoses. Kinked hoses can result in restricted air flow and lead to unpredictable system behavior. • Any observed improper system or component function: Immediately shut down the system and correct malfunction. • Excessive dirt build-up: Dirt and clutter can mask potentially hazardous situations. Caution: Leak detection solutions should be rinsed off after use. 4.5. Routine Maintenance Issues:

• Remove excessive dirt, grime and clutter from work areas. • Make sure all required guards and shields are in place. 4.6. Functional Test: Before initiating automatic operation, operate the system manually to make sure all required functions operate

properly and safely. 4.7. Service or Replacement Intervals: It is the user’s responsibility to establish appropriate service intervals. Valves, FRLs and vacuum

products contain components that age, harden, wear, and otherwise deteriorate over time. Environmental conditions can significantly accelerate this process. Valves, FRLs and vacuum components need to be serviced or replaced on routine intervals. Service intervals need to be established based on: • Previous performance experiences.

• Government and / or industrial standards. • When failures could result in unacceptable down time, equipment damage or personal injury risk. 4.8. Servicing or Replacing of any Worn or Damaged Parts: To avoid unpredictable system behavior that can cause death, personal

injury and property damage: • Follow all government, state and local safety and servicing practices prior to service including but not limited to all OSHA Lockout Tagout procedures (OSHA Standard – 29 CFR, Part 1910.147, Appendix A, The Control of Hazardous Energy – Lockout / Tagout).

• Disconnect electrical supply (when necessary) before installation, servicing, or conversion. • Disconnect air supply and depressurize all air lines connected to system and Pneumatic Division products before installation, service,

or conversion. • Installation, servicing, and / or conversion of these products must be performed by knowledgeable personnel who understand how

pneumatic products are to be applied. • After installation, servicing, or conversions air and electrical supplies (when necessary) should be connected and the product tested

for proper function and leakage. If audible leakage is present, or if the product does not operate properly, do not put product or system into use.

• Warnings and specifications on the product should not be covered or painted over. If masking is not possible, contact your local representative for replacement labels.

4.9. Putting Serviced System Back into Operation: Follow the guidelines above and all relevant Installation and Maintenance Instructions supplied with the valve FRL or vacuum component to insure proper function of the system.