sentryglas ionoplast interlayer architectural safety … ionoplast interlayer architectural safety...

8
SentryGlas ® ionoplast interlayer Architectural safety glass interlayer MAKE GLASS SAFER. BUILD STRONGER, LIGHTER. TO LEARN MORE ABOUT PUSHING THE LIMITS OF GLASS, VISIT WWW.SENTRYGLAS.COM IONOPLAST INTERLAYER

Upload: phungthien

Post on 20-Mar-2018

231 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

SentryGlas® ionoplast interlayer Architectural safety glass interlayer

MAKE GLASS SAFER. BUILD STRONGER, LIGHTER.

TO LEARN MORE ABOUT PUSHING THE LIMITS OF GLASS, VISIT

WWW.SENTRYGLAS.COM

IONOPLAST INTERLAYER

Page 2: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

5 times tougher, up to 100 times stiffer

Stronger and more rigid than conventional laminating materials, SentryGlas® ionoplast interlayers help create safety glass that protects against bigger storms, larger impacts and more powerful blasts. They become an engineered component within the glass, holding more weight, so the glass can serve as a more active element in the building envelope, increasing framing system design freedom.

All this, plus SentryGlas® improves long-term weather resistance of laminated glass systems.

SentryGlas® structural interlayer performance helps architects and glazed building system manufacturers meet society’s need for greater security,

healthful living, safety and maintenance ease. It helps builders do more with less, creating innovative new spaces, while providing greater protection for occupants.

The strength and open-edge durability of SentryGlas® interlayer enable frameless safety glass balustrades at sports stadiums

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

For glass that’s more than glassOriginally created for specialty markets such as high-security glazing and hurricane windows,

SentryGlas®

or engineers need a material that can make a difference in glass performance.

IONOPLAST INTERLAYER

Page 3: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

Before and After Breakage

SentryGlas® ionoplast interlayer is up to 100 times stiffer and 5 times stronger than traditional interlayers, helping thinner laminates meet

requirements. In many applications laminated glass made with SentryGlas® acts like an engineered composite, with low mechanical strain under loads, and outstanding post-breakage resistance to creep and collapse.

Bolted and Frameless Glass

Laminated glass made with stiff SentryGlas® can tolerate high stress loads. The interlayer becomes a higher performing structural layer in the multilayer composite. This gives architects and framing system engineers greater design freedom, useful in creating innovative new bolted and point-supported systems. Clean, smooth, expansive façades can now be engineered with minimal metal exposure and reduced need for four-sided edge framing.

A New Era For Exposed Edges

Gone are the days when laminated safety glass needed to be edge-framed partly to hide potential edge defects after weathering. Compared with many commonly used interlayers, the advanced polymer used in the SentryGlas® interlayer is less susceptible to moisture intrusion or other weathering effects.

Butt-Joined Freedom, Too

In testing with widely used glazing sealants, butt-joined panels of laminated glass made with SentryGlas® interlayers show excellent compatibility, remaining free of clouding or other edge defects after years of weather exposure and inspection. Butt-joined exterior glazing made with SentryGlas® and installed in buildings around the world continues to show outstanding reliability and freedom from edge defects.

Effortless, Ready Protection

By installing windows, doors, canopies, balustrades or curtain wall systems made with SentryGlas®, building owners get fulltime protection against wind-borne debris, the leading cause of window failure and property loss. And unlike owners who rely on shutters, owners who install glass made with SentryGlas® don’t have to be home to deploy their safety system when weather threatens. Their protection is already in place, guarding their investment in accordance with the world’s most demanding building codes.

(It can help defend against blasts, burglaries and break-ins, too.)

More Daylight, Less Worry

Because SentryGlas® is stiffer and tougher than conventional interlayers, it can withstand greater impacts (stronger winds and larger objects) in materials-saving thin glazing installations. It also can be used in larger panes of storm-protected glazing, increasing the vision are and reducing framing material and installation labor.

The extra stiffness of SentryGlas® also

with low postinstallation warpage.

withstand greater wind forces ... even when dry-glazed.

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

IONOPLAST INTERLAYER

Page 4: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

In post-breakage wind cycle testing required for tough new building codes, hurricane glass made with SentryGlas® lasts longer and maintains building protection long after alternative laminated safety glass has failed and opened the building interior to wind, rain, and the potential devastating effects of over-pressure.

Let’s Make Something Perfectly Clear

For all its strength, SentryGlas® interlayer comes with outstanding clarity. It starts clear, and stays clear ... with a Yellowness Index (YI) starting at 1.5 and lower (versus 6 to 12 for conventional interlayers).

That means extra transparency and more predictable color in laminated glass, more consistent with the glass color selected for the project. And with SentryGlas® interlayer the clarity is permanent; it won’t turn yellow over time. The interlayer stays clear, and requires no added adhesives, laminating aids or plasticizers to perform well in the laminate.Ultra-Clear Low-Iron Laminates

The outstanding clarity of SentryGlas® lets architects and designers realize their ultimate

time, designers can specify low-iron, laminated safety glass... and get the full, natural light transmittance they were looking for.

SentryGlas® interlayer strength and non-yellowing clarity enable use in elegant indoor and outdoor structural ap-

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

SentryGlas® helped create a 45-ft-tall glass facade at the Lincoln Center’s Alice Tully Hall in New York.

IONOPLAST INTERLAYER

Page 5: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

Property Units Metric (English)

Value ASTM Test

Young’s Modulus MPa (kpsi) 300 (43.5) D5026

Tensile Strength MPa (kpsi) 34.5 (5.0) D638

Elongation % 400 D638

Density g/cm3 (lb/in3) 0.95 (0.0343) D792

Flex Modulus 23°C (73 °F) MPa (kpsi) 345 (50) D790

Temperature at 0.46 MPa

°C (°F) 43 (110) D648

Melting Point °C (°F) 94 (201) (DSC)

Thermal Expansion (–20°C to 32°C)

10-5 cm/cm °C(mil/in °C)

10–15(0.10–0.15) D696

Helping builders and owners meet tough new wind storm codes

In areas subject to high winds or coastal storms, building owners who install protective laminated glass doors and windows often qualify for more affordable insurance.

SentryGlas® interlayers have been tested and accepted for use in hundreds of impact-resistant glazing systems meeting some of the toughest building codes in the world.

Protection that stays in place, 24 x 7

At hospitals and in other buildings where emergency preparedness matters most, and where “boarding up”

often choose safety glazing made with SentryGlas® to meet or exceed local building codes

Permanent protection, with a view...that’s how residents and building owners in hurricane- and cyclone-prone areas describe the carefree storm-preparedness of tough, impact-tested safety glass windows made with SentryGlas® interlayer.

Typical Physical Properties of SentryGlas® Interlayer

IONOPLAST INTERLAYER

Page 6: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

IONOPLAST INTERLAYER

IONOPLAST INTERLAYER

SentryGlas®

SPECIFYING AND TECHNICAL DATA

The following information is presented to help you evaluate or order SentryGlas® ionoplast interlayers.SentryGlas® interlayer is available on roll or as sheet and has a Yellowness-Index (YID) of < 2.5.

SHEET DIMENSIONS

Caliper mm (mil)

Width cm (in) Ordered, -0 +10 mm (-0 +0.4 in)

Length m (ft)

0,89 (35) 61-216 (24-85) up to 600 (up to 236)

1,52 (60) 61-216 (24-85) up to 600 (up to 236)

2,28 (90) 61-216 (24-85) up to 600 (up to 236)

2,53 (100) 61-183 (24-72) up to 600 (up to 236)

3,04 (120) 61-183 (24-72) up to 600 (up to 236)

In addition to the standard stock sizes above, SentryGlas®

sheet, which means that none of the material is wasted. In all cases, sheet thickness is 0.89 mm (35 mil), 1.52 mm (60 mil) or 2.28 mm (90 mil). As these custom sizes require special handling/cutting, lead times are longer.

sheet offering feel free to contact us.

ROLL DIMENSIONS

Caliper mm (mil)

Width cm (in) Ordered, -0 +10 mm (-0 +0.4 in)

Length m (ft)

0,76 (30) 122 (48) 200 (656)

0,76 (30) 153 (60) 200 (656)

0,76 (30) 183 (72) 200 (656)

0,76 (30) 153 (60) 50 (164)

0,89 (35) 122 (48) 200 (656)

0,89 (35) 153 (60) 200 (656)

0,89 (35) 183 (72) 200 (656)

0,89 (35) 153 (60) 50 (164)

0,89 (35) 225 (88) 50 (164)

0,89 (35) 225 (88) 200 (656)

0,89 (35) 240 (96) 50 (164)

0,89 (35) 240 (96) 200 (656)

www.sentryglas.com

SentryGlas® Elastic Properties (SG5000)

TABLE 1 — LAMINATE PROPERTIES

Property Units Metric (English) Value Test

Haze % < 2 ASTM D1003

Impact test 0,23 kg (0.5 lb) m (ft) > 9.14 (> 30) ANSI Z26.1

Boil test 2 hr – No defects ANSI Z26.1

Bake test 2 hr/100 °C – No defects ANSI Z26.1

TABLE 2 — INTERLAYER TYPICAL PROPERTIES

Property Units Metric (English) Value ASTM Test

Young’s Modulus Mpa (kpsi) 300 (43.5) D5026

Tear Strength MJ/m3 (ft lb/in3) 50 (604) D638

Tensile Strength Mpa (kpsi) 34.5 (5.0) D638

Elongation % (%) 400 (400) D638

Density g/cm3 (lb/in3) 0.95 (0.0343) D792

Flex Modulus 23 °C (73 °F) Mpa (kpsi) 345 (50) D790

(HDT) @ 0.46 MPa °C (°F) 43 (110) D648

Melting Point °C (°F) 94 (201) (DSC)

Coeff. of Thermal Expansion (-20 °C to 32 °C) 10-3 cm/cm °C (mils/in °C) 10 – 15

(0.10 – 0.15) D696

Thermal Conductivity W/M-K (BTU-in/hr-ft2 °F) 0.246 (1.71)

www.sentryglas.com

when double stacking and not intended to be used as a single ply. Single ply use has not been tested to determine perfor-mance against any safety glazing codes or standards. 0,89 mm (35 mil) interlayers typically require high quality tempered

the standard thickness for minimally supported applications.

for anti-intrusion, hurricane and other types of security ap-

plications. Glass producers and laminators require interlayers to be supplied either in sheet form or on rolls. SentryGlas® Ionoplast interlayers are available in both formats. For faster deliveries, SentryGlas® ionoplast interlayer is stocked in standard thicknesses (calipers) of 0.89 mm (35 mil), 1.52 mm (60 mil) and 2.28 mm (90 mil) sheets. SentryGlas® ionoplast interlayer on roll is available in 0,76 mm (30 mil) and 0.89 mm (35 mil) thickness.

Page 7: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

IONOPLAST INTERLAYER

IONOPLAST INTERLAYER

SentryGlas®

SPECIFYING AND TECHNICAL DATA

The following information is presented to help you evaluate or order SentryGlas® ionoplast interlayers.SentryGlas® interlayer is available on roll or as sheet and has a Yellowness-Index (YID) of < 2.5.

SHEET DIMENSIONS

Caliper mm (mil)

Width cm (in) Ordered, -0 +10 mm (-0 +0.4 in)

Length m (ft)

0,89 (35) 61-216 (24-85) up to 600 (up to 236)

1,52 (60) 61-216 (24-85) up to 600 (up to 236)

2,28 (90) 61-216 (24-85) up to 600 (up to 236)

2,53 (100) 61-183 (24-72) up to 600 (up to 236)

3,04 (120) 61-183 (24-72) up to 600 (up to 236)

In addition to the standard stock sizes above, SentryGlas®

sheet, which means that none of the material is wasted. In all cases, sheet thickness is 0.89 mm (35 mil), 1.52 mm (60 mil) or 2.28 mm (90 mil). As these custom sizes require special handling/cutting, lead times are longer.

sheet offering feel free to contact us.

ROLL DIMENSIONS

Caliper mm (mil)

Width cm (in) Ordered, -0 +10 mm (-0 +0.4 in)

Length m (ft)

0,76 (30) 122 (48) 200 (656)

0,76 (30) 153 (60) 200 (656)

0,76 (30) 183 (72) 200 (656)

0,76 (30) 153 (60) 50 (164)

0,89 (35) 122 (48) 200 (656)

0,89 (35) 153 (60) 200 (656)

0,89 (35) 183 (72) 200 (656)

0,89 (35) 153 (60) 50 (164)

0,89 (35) 225 (88) 50 (164)

0,89 (35) 225 (88) 200 (656)

0,89 (35) 240 (96) 50 (164)

0,89 (35) 240 (96) 200 (656)

www.sentryglas.com

SentryGlas® Elastic Properties (SG5000)

TABLE 1 — LAMINATE PROPERTIES

Property Units Metric (English) Value Test

Haze % < 2 ASTM D1003

Impact test 0,23 kg (0.5 lb) m (ft) > 9.14 (> 30) ANSI Z26.1

Boil test 2 hr – No defects ANSI Z26.1

Bake test 2 hr/100 °C – No defects ANSI Z26.1

TABLE 2 — INTERLAYER TYPICAL PROPERTIES

Property Units Metric (English) Value ASTM Test

Young’s Modulus Mpa (kpsi) 300 (43.5) D5026

Tear Strength MJ/m3 (ft lb/in3) 50 (604) D638

Tensile Strength Mpa (kpsi) 34.5 (5.0) D638

Elongation % (%) 400 (400) D638

Density g/cm3 (lb/in3) 0.95 (0.0343) D792

Flex Modulus 23 °C (73 °F) Mpa (kpsi) 345 (50) D790

(HDT) @ 0.46 MPa °C (°F) 43 (110) D648

Melting Point °C (°F) 94 (201) (DSC)

Coeff. of Thermal Expansion (-20 °C to 32 °C) 10-3 cm/cm °C (mils/in °C) 10 – 15

(0.10 – 0.15) D696

Thermal Conductivity W/M-K (BTU-in/hr-ft2 °F) 0.246 (1.71)

www.sentryglas.com

when double stacking and not intended to be used as a single ply. Single ply use has not been tested to determine perfor-mance against any safety glazing codes or standards. 0,89 mm (35 mil) interlayers typically require high quality tempered

the standard thickness for minimally supported applications.

for anti-intrusion, hurricane and other types of security ap-

plications. Glass producers and laminators require interlayers to be supplied either in sheet form or on rolls. SentryGlas® Ionoplast interlayers are available in both formats. For faster deliveries, SentryGlas® ionoplast interlayer is stocked in standard thicknesses (calipers) of 0.89 mm (35 mil), 1.52 mm (60 mil) and 2.28 mm (90 mil) sheets. SentryGlas® ionoplast interlayer on roll is available in 0,76 mm (30 mil) and 0.89 mm (35 mil) thickness.

Page 8: SentryGlas ionoplast interlayer Architectural safety … ionoplast interlayer Architectural safety glass interlayer MAKE GLASS ... Originally created for specialty markets such as

Copyright ©2014 Kuraray. All rights reserved. Front Cover Photo: Bolzano (Italy) Museion design by KSV Krüger Schuberth Vandreike; photo by Othmar Seehauser; Background Photo pages 2,3,4 by courtesy of W&W Glass; images pages 3+4 by courtesy of Kuraray; images 1+2 on page 5 by courtesy of Kuraray, image 3 by courtesy of L. Torri; images page 5 by courtesy of DuPont; image page 6 by courtesy of Kuraray.SentryGlas®

license by Kuraray. The information provided herein corresponds to our knowledge on the subject at the date of its publication. This information may be subject to revision as new knowledge and experience becomes available. The data provided fall within the normal range of product

any other materials or additives or in any process, unless expressly indicated otherwise. The data provided should not be used to establish are not intended to substitute for any testing you may need to conduct to r your particular purposes. Since Kuraray cannot anticipate all variations in

actual end-use conditions, Kuraray make no warranties and assume no liability in connection with any use of this information. Nothing in this publication is to be considered as a license to operate under a recommendation to infringe any patent rights. Document Ref. GLS-SG-2014-01

SentryGlas® ionoplast interlayer − Make glass safer. Build stronger, lighter

REGIONAL CONTACT CENTERS Kuraray Co., LTDOte Center Bldg.1-1-3, OtemachiChiyoda-ku, Tokyo, 100-8115, JapanPhone: +81 3 6701 1508

Kuraray Europe GmbHGlass Laminating Solutions Philipp-Reis-Str. 465795 Hattersheim, GermanyPhone: +49 (0) 69 30585300

Kuraray Americas, Inc. 2625 Bay Area Blvd. #600Houston TX 77058, USAPhone: +1.800.423.9762

Kuraray Mexico S.de R.L. de C.V.Homero 206, Polanco V seccion, cp 11570, Mexico City, MexicoPhone: +52 55 5722 1043

For further information about SentryGlas®, please visit

www.sentryglas.com

Available From Leading Laminators And Glazing System InstallersExperienced glass laminators, framing and facade system specialists and glazing contractors are available worldwide to meet the needs of architects and system designers specifying SentryGlas®.

glass roof made with SentryGlas®.

IONOPLAST INTERLAYER