selectronic™ model numbers proximity ... 9 6 2 5 8 10 fig. 9 fig. 8 5 7 1. insert the side inlet...

13
Installation Instructions Installation Instructions Certified to comply with ASME A112.19.2M © 2009 AS America, Inc. NOTE TO INSTALLER: Please give this manual to the customer after installation. SELECTRONIC™ PROXIMITY CONCEALED URINAL FLUSH VALVE 1.0 & 0.5 GPF Concealed Flushometer for 3/4" Top or Back Spud Urinals CLOG RESISTANT • Self-cleaning piston valve prevents clogging and reduces maintenance. ONE SENSOR FITS ALL • Only 1 sensor for entire Selectronic™ line of faucets, urinals, and ush valves. • Range can be adjusted manually or with optional remote control. • Sensor Features Low Battery Indicator. M968547 REV. 1.3 To learn more about American Standard Faucets visit our website at: www.americanstandard-us.com or U.S. customer's e-mail us at: [email protected] For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369) (In Toronto Area only: 1-905-3061093) 6061.310 6062.310 6063.310 6061.210 6062.210 6063.210 6061.305 6062.305 6063.305 6061.205 6062.205 6063.205 MODEL NUMBERS

Upload: vuhanh

Post on 05-Jul-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

Ins

tall

ati

on

In

str

uc

tio

ns

Ins

tall

ati

on

In

str

uc

tio

ns

(In Toronto Area only: 1-905-3061093)

Certified to comply with ASME A112.19.2M

© 2009 AS America, Inc.

NOTE TO INSTALLER: Please give this manual to the customer after installation.

SELECTRONIC™PROXIMITY CONCEALEDURINAL FLUSH VALVE1.0 & 0.5 GPF

Concealed Flushometerfor 3/4" Top or Back Spud Urinals

CLOG RESISTANT• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and !ush valves.• Range can be adjusted manually or with optional remote control.• Sensor Features Low Battery Indicator.

M968547 REV. 1.3

To learn more about American Standard Faucets visit our website at: www.americanstandard-us.comor U.S. customer's e-mail us at: [email protected]

For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-3061093)

6061.3106062.310 6063.3106061.2106062.210 6063.210

6061.3056062.305 6063.3056061.2056062.205 6063.205

MODEL NUMBERS

Page 2: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

All American Standard Products Are Water Tested At Our Factory. Some Residual Water May Remain In The Valve During Shipping.

Thank you for selecting American-Standard...the benchmark of fine quality for over 100 years. To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

UNPACKING1. Remove the Flush Valve items from the carton. The illustration below shows all items after they have been removed from the carton. Some items may be packaged partially assembled to other items.

9

1

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR ACLOTH WITH A COARSE SURFACE.

CARE INSTRUCTIONS FOR CHROME PLATED ITEMS:

8a. AC Power Supply [Model# 6062]8b. DC Power Supply8c. 10’ Extension Wire for Multi-AC9. Installation Instructions

1. Flush Valve Assembly2. Electrical Box3. Cover Plate with Sensor4. Supply Stop5. Sweat Solder Adapter

6. Manual Override Hoses

7a. Vacuum Breaker Flush Connection (Top Spud)

7b. Vacuum Breaker Flush Connection (Wall-Mount Back Spud)

7a

8a 8b 8c

7b

3

2

4

5

DO NOT REMOVE PROTECTIVE FILM FROM SENSOREYE UNTIL INSTALLATION IS COMPLETE.

T O P

1

6

Ins

tall

ati

on

In

str

uc

tio

ns

Ins

tall

ati

on

In

str

uc

tio

ns

(In Toronto Area only: 1-905-3061093)

Certified to comply with ASME A112.19.2M

© 2009 AS America, Inc.

NOTE TO INSTALLER: Please give this manual to the customer after installation.

SELECTRONIC™PROXIMITY CONCEALEDURINAL FLUSH VALVE1.0 & 0.5 GPF

Concealed Flushometerfor 3/4" Top or Back Spud Urinals

CLOG RESISTANT• Self-cleaning piston valve prevents clogging and reduces maintenance.

ONE SENSOR FITS ALL• Only 1 sensor for entire Selectronic™ line of faucets, urinals, and !ush valves.• Range can be adjusted manually or with optional remote control.• Sensor Features Low Battery Indicator.

M968547 REV. 1.3

To learn more about American Standard Faucets visit our website at: www.americanstandard-us.comor U.S. customer's e-mail us at: [email protected]

For Parts, Service, Warranty or other Assistance, please call 1-800-442-1902 (In Canada: 1-800-387-0369)

(In Toronto Area only: 1-905-3061093)

6061.3106062.310 6063.3106061.2106062.210 6063.210

6061.3056062.305 6063.3056061.2056062.205 6063.205

MODEL NUMBERS

M968547 REV. 1.3

Page 3: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

RECOMMENDED TOOLS; Fig. 2 Fig. 21.2.3.4.5.6.7.8.9.

10.

Teflon Tape Flat Blade ScrewdriverAdjustable Wrench Tape Measure HacksawTubing CutterFileFor Sweat Connection; Solder and Torch2.5mm Hex Wrench1.5mm Hex Wrench

1 2 3

4

56

7 9 10

8

PRIOR TO INSTALLATIONNote: Prior to installing the Selectronic™Flush Valve the following items must be installed.

1. Urinal

2. Drain line

3. Water supply line

• Flush all water lines prior to operation (See Step 4). Dirt and debris can cause flush valve to run continuously.

• With the exception of Supply Stop Inlet, DO NOT use pipe sealant or plumbing grease on any valve component or coupling!

• Protect the chrome or special finish on chrome plated items.DO NOT USE toothed tools on finished surfaces to install or service these valves. Also see “Care and Cleaning” section of this manual.

• This product contains mechanical and/or electrical components that are subject to normal wear. These components should be checked on a regular basis and replaced as needed to maintain the valve’s performance.

IMPORTANT:• All plumbing must be installed in accordance with applicable codes and regulations.

• Water supply lines must be sized to provide an adequate volume of water for each fixture.

2

Fig. 1Roughing-in Dimensions

GENERAL DESCRIPTION:

10'

Concealed Flushometerfor 3/4" Spud Fixtures

SELECTRONIC™PROXIMITY URINALFLUSH VALVE

60mm(2-3/4) DIA.

25mm(1) MAX.

160mm(6-1/4)

OVERRIDEBUTTON

160mm(6-1/4)

305mm(12) REF.

127X127mm(5X5 CUTOUT

FOR BOX)

FOR LOCATION OF INLETSUPPLY ON BACK INLET FIXTURES,

REFER TO FIXTURE BEING INSTALLEDFOR CORRECT HEIGHT FROM

FINISHED FLOOR

FOR 3/4 TOPSPUD FIXTURE

FINISHED FLOOR

FINISHED WALL

BACK SPUDFIXTURES

TOP SPUDFIXTURES

SENSOR

115mm-134mm(4-1/2 TO 5-1/4)

*Note: The Critical Line (-C-L-) on VacuumBreaker must typically be 6" (152mm) min.above fixture. Consult Codes for details.

-C-L-*

WALL THICKNESS

32mm(1-1/4) DIA.

32mm(1-1/4DIA.)

-C-L-

SUPPLYDN 19mm(3/4) I.P.S. 51mm (2)

+ WALL THICKNESS

114mm(4-1/2) MAX.

73 TO 137mm(2-7/8) MIN. TO5-3/8) MAX.

292mm (11-1/2) MAX.

152mm(6) MIN.

403 TO 441mm(15-7/8) MIN. TO

(17-3/8) MAX.

Exclusive, self cleaning piston-type flush valve with proximity operation and manual override. Operates on DC (batter y)or AC power. Recommended operating pressure 25psi (flowing) to 80 psi (static). Can install left or right-handed. Detection Zone can also be adjusted manually, or with optional remote control.

M968547 REV. 1.3

Page 4: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

Fig. 4

Fig. 3a

Fig. 5

3

INSTALL ELECTRICAL BOXASSEMBLY; Fig. 31. Cut a 127x127mm (5"x 5") opening in finished wall for ELECTRICAL BOX (1) at the deminsion shown in Fig.3.

2. Rotate the 4 MOUNTING TABS (2) flat against the electrical box. Holding the MOUNTING TABS (2) in position install the ELECTRICAL BOX (1) into the opening.Make sure the MOUNTING TABS (2) are behind the wall.

3. Tighten the the 4 MOUNTING SCREWS (3) until the ELECTRICAL BOX (1) is almost secure in the wall. Before tighting fully rest a level at the top edge of the ELECTRICAL BOX (1) and make sure the box is level, then tighten fully. Fig. 3a.

4. *Cut a 2" hole for supply to fixture at deminsion shown.

1 Fig.3 (TOP SPUD FIXTURE ILLUSTRATED)

1

3

2

2

1

1

1. Open SUPPLY STOP (1).

3. Turn on water supply to flush line of any debris orsediment.

4. Close SUPPLY STOP (1) and turn off water supply line.

FLUSH OUT SUPPLY LINES; Fig. 53

?mm(?)

*FOR HOLE LOCATION OFSUPPLY ON BACK INLETFIXTURES, REFER TO FIXTUREBEING INSTALLED FOR CORRECTHEIGHT FROM FINISHED FLOOR

127mm(5)

*114mm(4-1-2) MAX.

305mm(12) REF.

127mm(5)

INSTALL SWEAT SOLDERADAPTER; Fig. 4CAUTION Turn water supplies off

before beginning

Note: Control stop inlet is 1" IPS. For optional sweat connection, install Sweat Solder Adapter (1) (Supplied) for 1" copper pipe supply line. Fig. 4.

1. Clean the end of the supply pipe. Push the threaded ADAPTER (1) on until it is seated against the internal stop. Sweat the ADAPTER (1) to the pipe.

2. From behind the wall install the CONTROL STOP (2) to the water supply line with the outlet positioned as required.

3. Support piping as required.

2

T O P

FILEEDGES

CLEAN & SOLDER TO ADAPTER (1)

115mm-134mm(4-1/2 TO 5-1/4)

CONTROL STOPDN 25mm(1" I.P.S.)

CONTROLSTOP

OUTLET

CLOCKWISE CLOSESCONTROL STOP

COUNTER-CLOCKWISEOPENS CONTROL STOP

T O P

T O P

2

M968547 REV. 1.3

Page 5: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

4

Fig. 6

Fig. 6a

Fig. 6b

Fig. 6c

1

23

43/4" TOP SPUD

88a

13 1512

11

6a 7

7a5

69

FLANGE END UP

FLANGE END

10

10

16

14

BACK SPUDINSTALLATION

TOP SPUDINSTALLATION

TOP SPUDINSTALLATION

2

34 INSTALL VACUUM BREAKER ANDFLUSH CONNECTIONS; Fig. 64

1. Place the SPUD FLANGE (1) over the spud on the Fixture. Fig. 6.

2. Thread SPUD COUPLING NUT (2) onto Spud. Make sure SEAL WASHER (4) and FRICTION WASHER (3) are installed. Do not tighten fully. Fig. 6.

3. Remove the COUPLING NUTS (6) from the CHROME ELBOW (5). Make sure there are a RUBBER (7) & FIBER GASKET (8) in each. Fig. 6a.

4. With the flange end up slide the FIBER GASKET (8) and COUPLING NUT (6) onto the DOWN TUBE (9). Place the RUBBER GASKET (7) onto the flange. Now connect the COUPLING NUT (6) to the CHROME ELBOW (5) and tighten fully. Insert the DOWN TUBE (5) with CHROME ELBOW (5) into the SPUD COUPLING NUT (2) and push it down. Do not tighten fully. Fig. 6a. Note: If center line of ELBOW (5) does not line up with hole in wall, then you may cut DOWN TUBE (9).

5. Replace COUPLING NUT (6a), RUBBER (7a) and FIBER GASKET (8a) on CHROME ELBOW (5), do not tighten. Fig. 6a.

6. Measure and cut the HORIZONTAL TUBE (10) to length required. Important: Make sure that there is a minimum of 1-1/4 for engagement with coupling when making your measurement. Assemble the BRASS ELBOW (11) to the HORIZONTAL TUBE (10). Fig. 6b.

7. With the flange end toward the BRASS ELBOW (11) slide the FIBER GASKET (12) and COUPLING NUT (13) onto the HORIZONTAL TUBE (10). Place the RUBBER GASKET (14) between the flange and the BRASS ELBOW (11) and tighten assembly fully. Fig. 6b.

8. From behind the wall install the ELBOW AND TUBE ASSEMBLY (11, 10) through the hole in the wall. Install WALL ESCUTCHEON (15) onto HORIZONTAL TUBE (10). Push the tube into the CHROME ELBOW (5), do not tighten coupling nut fully. Fig. 6b.

For back spud installations: Follow steps #1 and #2 to install the spud coupling kit. Push the HORIZONTAL TUBE (10) into the spud connection on the back of the fixture. Do not tighten fully. If spud coupling kit is not required install HORIZONTAL TUBE (10) into back spud on fixture and hand tighten. Fig. 6b.

10. All installations: If required cut scored VACUUM BREAKER PIPE (16) to fit, leave a minimum of 1-1/4 (32mm) of pipe to ensure engagement with compression coupling. Install VACUUM BREAKER PIPE (16) into BRASS ELBOW (11) and hand tighten coupling nut. Fig. 6c. Note: If cutting VACUUM BREAKER PIPE (16) to size, note that Critical Line (C/L) on Vacuum Breaker must typically be 6" (152mm) above fixture. Consult Code for details.

BACK SPUDINSTALLATION

11

M968547 REV. 1.3

Page 6: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

7

9

6

25

810

Fig. 9

Fig. 8

5

7

1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8.Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape.

INSTALL FLUSH VALVE; Fig. 85

1. Align the FLUSH VALVE (2) (Fig. 9) directly above the VACUUM BREAKER TUBE (7) and VACUUM COUPLING NUT (6). Make sure that GASKET (10) is installed.Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 9.

2. Pull the VACUUM BREAKER TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 9.

3. Lightly tighten the COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten all couplings to make water tight connections. Fig. 9.

4. Secure piping behind wall as required.

CONNECT FLUSH VALVE TOPIPING; Fig. 9

6

3

25

1

4

121mm,+13mm, -6mm(4-3/4)(+1/2, -1/4)

M968547 REV. 1.3

Page 7: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

6

11

6

1. Remove the four COVER SCREWS (1) and COVER from (2) ELECTRICAL BOX (4). Fig. 10.

2. Pull the CIRCUIT BOARD (3) out from ELECTRICAL BOX (4). Fig. 10.

3. Knock out lower blank in ELECTRICAL BOX (4) with flat blade screwdriver. Install from the back of ELECTRICAL BOX (4) the POWER SUPPLY GROMMET (8). Fig. 10a.

4. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown.Feed the Red and Black wires through the back opening in the ELECTRICAL BOX (4). Fig. 10a.

5. From back of ELECTRICAL BOX (4) remove SPLIT PLUG (8a) from POWER SUPPLY GROMMET (8). Insert POWER CORD CONNECTOR (9) through POWER SUPPLY GROMMET (8). Insert POWER CORD (10) into SPLIT PLUG (8a). Push SPLIT PLUG (8a) into POWER SUPPLY GROMMET (8) to seal. Fig. 10b.

6. Insert POWER SUPPLY CONNECTOR (9) into RECEPTOR (11) on CIRCUIT BOARD (3). Install CIRCUIT BOARD (3) into ELECTRICAL BOX (4).Fig. 10b.

7. Install the SENSOR WIRE GROMMET (15) into the COVER (2) as shown. Remove the SPLIT PLUG (15a) from SENSOR WIRE GROMMET (15). Insert SENSOR WIRE CONNECTOR (12) through SENSOR WIRE GROMMET (15). Insert SENSOR WIRE (13) into SPLIT PLUG (15a). Push SPLIT PLUG (15a) into SENSOR WIRE GROMMET (15) to seal. Fig. 10c.

8. Insert SENSOR WIRE CONNECTOR (12) into CIRCUIT BOARD RECEPTOR (14) slot. Fig. 10c.

9. Replace COVER (2). Tighten COVER SCREWS (1) firmly.

CONNECT FRONT PANEL TOELECTRICAL BOX (AC POWER);Fig. 10

7 Fig. 10

Fig. 10a

Fig. 10b

Fig. 10c

T O P

T O P

1

2

3

4

4

4

6 5

7

3

8

9

11

9

8

15

2

15a

1

12

13

8a10

KNOCK OUTBLANK

BLACK &RED WIRES

14

T O P

8

T O P

7

M968547 REV. 1.3

Page 8: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

7

T O P

1. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 10.

2. Install BATTERY (4) into holder on DC circuit board. Press BATTERY (4) down (contacts facing downward) into position until tabs lock BATTERY (4) into place.

3. Attach the SAFETY CHAIN (5) from the FRONT PANEL (6) to the MOUNTING POST (7) as shown.Feed the Red and Black wires through the back opening in the ELECTRICAL BOX (3). Fig. 11a.

4. Install the SENSOR WIRE GROMMET (11) into the COVER (2) as shown. Remove the SPLIT PLUG (11a) from SENSOR WIRE GROMMET (11). Insert SENSOR WIRE CONNECTOR (8) through SENSOR WIRE GROMMET (11). Insert SENSOR WIRE (9) into SPLIT PLUG (11a). Push SPLIT PLUG (11a) into SENSOR WIRE GROMMET (11) to seal. Fig. 11b.

8. Insert SENSOR WIRE CONNECTOR (8) into CIRCUIT BOARD RECEPTOR (10) slot. Fig. 11b.

9. Replace COVER (2). Tighten COVER SCREWS (1) firmly.

Fig. 11a

Fig. 11b

Fig. 12

1

2

3

4

6

11

211a

8

9

1

CONNECT FRONT PANEL TOELECTRICAL BOX (DC POWERBATTERY); Fig. 11

8 Fig. 11

1. Install the two TABS (1) on the back side of FRONT PANEL (2) into the two SLOTS (3) located on the top edge of the ELECTRICAL BOX (4). Fig. 12.

2. Push on the bottom edge of the FRONT PANEL (2) until it snaps into place. If FRONT PANEL (2) will not snap into place, then loosen the MOUNTING SCREWS (6) on the ELECTRICAL BOX (4) slightley.Fig. 12.

3. To remove FRONT PANEL (2) insert WIRE KEY (5) (supplied) into the two holes located at the bottom of the FRONT PANEL (2). Push the WIRE KEY (5) up until it releases the bottom clips. Pull the bottom edge away and lift the FRONT PANEL (2) off. Fig. 12.

INSTALL FRONT PANEL; Fig. 129

PUSH TOSNAP PANELINTO PLACE

5

6

2

T O P

5

7

BLACK &RED WIRES

T O P

1

23

4

T O P

3

10

M968547 REV. 1.3

Page 9: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

8

1

4

2

5

5

6

BLUEHOSE

BLACKHOSE

1. Push the BLACK HOSE (1) into the BOTTOM HOSE CONNECTOR (2) and the other end into the back of the OVERRIDE SWITCH (3).

2. Push the BLUE HOSE (4) into the TOP HOSE CONNECTOR (5) on the valve and the other end into the BOTTOM CONNECTOR (6) on the OVERRIDE SWITCH (3).

CONNECT OVERRIDE HOSES,AC & DC POWER; Fig. 1310

1. Push the RED WIRE CONNECTOR (1) onto the SOLENOID PIN (2) with Red Stripe. Push the BLACK WIRE CONNECTOR (3) onto the other SOLENOID PIN (4). Push the wire connectors all the way down.

2. Code approved Electrical Outlet provided by others, (120V 50/60 Hz)..

3. Plug AC POWER SUPPLY (5) into Outlet.

CONNECT SOLENOID WIRINGAND POWER SUPPLY; Fig. 1411

Fig. 13

Fig. 14

3

REDWIRE

REDSTRIPE

BLACKWIRE

ELECTRICALOUTLET

1 3

2 4

M968547 REV. 1.3

Page 10: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

9

FOR AC-VERSION(MULTI HOOK-UP); Fig. 15, 15a

Unit #1

Unit #1

Unit #2 Unit #3

1. Remove the COVER SCREWS (1) and COVER (2) from each ELECTRICAL BOX (3).

2. See AC Version Electrical Hook-up for Unit #1 of the Multi hook-up.

3. Install SENSOR WIRE GROMMET (4) and FLUSH VALVE SENSOR WIRE (5) into the COVER (2) of each unit. Insert the flush valve sensor wire connector into the CENTER CIRCUIT BOARD RECEPTOR (6) on each unit. Fig. 15a.

4. Remove the SPLIT PLUG (7a) from the SENSOR WIRE GROMMET (7) on the left side of each ELECTRICAL BOX (3).

5. Take the 10 ft. EXTENSION WIRE (8) from Unit #2 and insert one end of the EXTENSION WIRE CONNECTOR (9) through the SENSOR WIRE GROMMET (7) on left side of Unit #1. Insert EXTENSION WIRE (8) into SPLIT PLUG (7a). Push SPLIT PLUG (7a) into SENSOR WIRE GROMMET (7) to seal. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10). Fig. 15a.

6. Insert other end of EXTENSION WIRE (8) into SENSOR WIRE GROMMET (7) on left side of Unit #2. Insert that EXTENSION WIRE CONNECTOR (9) into the LOWER CIRCUIT BOARD RECEPTOR (10) of Unit #2. Fig. 15b.

7. On Unit #2 ELECTRICAL BOX (3) remove ROUND KNOCK-OUT (11) on the bottom of the box by pressing a flathead screwdriver into the center of the ROUND KNOCK-OUT (11). Fig 15b.

8. Insert additional SENSOR WIRE GROMMET (12) included with Unit #2 into the knock-out opening in the bottom of the ELECTRICAL BOX (3). Take the 10 FT. EXTENSION WIRE (8) from Unit #3 and insert one end into the SENSOR WIRE GROMMET (12) in the bottom of the ELECTRICAL BOX (3) of Unit #2. Insert EXTENSION WIRE CONNECTOR (9a) into TOP CIRCUIT BOARD RECEPTOR (13) on Unit #2 . Fig. 15b.

9. Insert the other end of the EXTENSION WIRE (8) from Unit #3 into the SENSOR WIRE GROMMET (7) on the left side of Unit #3. Insert EXTENSION WIRE CONNECTOR (9) into LOWER CIRCUIT BOARD RECEPTOR (10) on Unit #3.

10. Repeat Steps 7 to 9 as necessary for additional Multi-AC Units.

11. Once all wire connections are made. Install the COVER (2) and COVER SCREWS (1) onto each ELECTRICAL BOX (3).

Fig. 15

Fig. 15a

Fig. 15b

12

T O P T O P T O P

27a

7

8

3

6

1

54

9

T O P

10

SENSOR WIRECONNECTOR

SENSORWIRE

FROM UNIT #2

Unit #2

7a

78

3

9a

T O P

12

7

12

8

8 8 8

1211

109

SENSOR WIRECONNECTOR

FROMUNIT #3

BACK OF BOX (3)

FROM UNIT #1

REMOVE KNOCK-OUT (11),INSERT WIRE GROMMET (12)

1

2

SENSORWIRE

SENSORWIRE

610

7

610

13

7

610

13

13

M968547 REV. 1.3

Page 11: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

10

Fig. 17

CLOCKWISE CLOSESCONTROL STOP

COUNTER-CLOCKWISEOPENS CONTROL STOP1

2

3

57

6

T O P

1. Remove FRONT PANEL. For removing front panel see Step 9 for instructions.

2. Remove the four COVER SCREWS (1) and COVER (2) from ELECTRICAL BOX (3). Fig. 16.

3. Disconnect GREY SENSOR WIRE (4) from CIRCUIT BOARD (5).

4. Remove CIRCUIT BOARD (5) from ELECTRICAL BOX (3). Fig. 16a. 5. With your thumbs, spread the two TABS (6) on battery holder apart and remove the BATTERY (7).

2. Install NEW BATTERY (7) into holder on DC circuit board. Press BATTERY (7) down (contacts facing downward) into position until TABS (6) lock BATTERY (7) into place.

6. Install CUIRCUIT BOARD (5) and connect GREY SENSOR WIRE (4). 7. Install COVER (2) and SCREWS (1).

8. Replace and FRONT PANEL. See Step 9 for instructions on installing front panel.

HOW TO INSTALL NEW BATTERY;Fig. 1613 Fig. 16

Fig. 16a

1

4

23

5

T O P

14IMPORTANT: To avoid overflowing, the SUPPLY STOP (2) must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture. The fixture must be able to handle a continuous flow in case of a flush valve failure.Valve is designed to provide stated flush volume with a 10 GPM flow rate.

1. After installation is complete, peel off the PROTECTIVE FILM (1) from the sensor. Standing to one side, block the sensor with your hand for 10 seconds. Remove your hand and listen for audible “click” from within the valve.

2. Turn on SUPPLY STOP (2) 1/4 turn to 1/2 turn(CCW) and test for leaks. Note: Unit may flush for approximately 5 to 10 sec. when water is first turned on. If flow persists, turn water off and repeat step #1 above.

3. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor; unit will flush in approximately 3 seconds.

4. Adjust SUPPLY STOP (2) after each flush until the stated flush volume is achieved, no splashing occurs and the fixture is properly cleansed.

ADJUST SUPPLY STOP; Fig. 17

M968547 REV. 1.3

Page 12: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

11

Fig. 19 Fig. 19a

1" - 2" (30mm - 50mm)

BLINKING LED

6

MAXIMUMDETECTION ZONE400mm TO 800mm(15-3/4" TO 31-1/2")

BLINKING LED

6

T O P

Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below.

1. Remove FRONT PANEL (1). See Step 9 for removing front panel instructions.

2. Remove the four COVER SCREWS (2) and COVER (3) from ELECTRICAL BOX (4). Fig. 18.

3. Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6).

4. Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note: You have 5 seconds after connecting cable to begin program process.

5. While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19.

6. When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a.Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor. 7. Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.

8. Replace COVER (3). Tighten COVER SCREWS (2) firmly.

9. Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel.

10. Actuate the FLUSH VALVE: A) Cover sensor with hand for 10 seconds. NOTE: Stand outside of sensor detection aera. B) Remove hand from in front of the sensor, unit will flush in approximately 3 seconds.

HOW TO SET DETECTION RANGE(If Required) ; Fig. 18 & 1915 Fig. 18

1

2

5

34

5

M968547 REV. 1.3

Page 13: SELECTRONIC™ MODEL NUMBERS PROXIMITY ... 9 6 2 5 8 10 Fig. 9 Fig. 8 5 7 1. Insert the side INLET FLANGE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the INLET FLANGE

12

IS S

TOP

VA

LVE

OP

EN

?

LOO

K F

OR

RE

PE

ATE

DD

OU

BLE

FLA

SH

ON

SE

NS

OR

YE

SIN

STA

LL N

EW

BA

TTE

RY

TRY

MA

NU

AL

VALV

E B

UTT

ON

;W

ILL

THE

UN

IT F

LUS

H?

NO

RE

PLA

CE

PIS

TON

KIT

INS

TALL

NE

W B

ATT

ER

Y o

r P

LUG

-INA

C P

OW

ER

SU

PP

LYSE

E ST

EP 1

3, p

age

10 in

man

ual

NO

RE

PLA

CE

SE

NS

OR

NO

YE

S

NO

NO

YE

S

YE

S

OP

EN

VA

LVE

UN

IT W

ILL

ON

LY F

LUS

H M

AN

UA

LLY

LOO

K F

OR

RE

PE

ATE

DD

OU

BLE

FLA

SH

ON

SE

NS

OR

RE

TRY

AU

TOM

ATI

C F

LUS

H.

DO

ES

TH

E U

NIT

FLU

SH

?

RE

TRY

AU

TOM

ATI

C F

LUS

H.

TES

T S

EN

SO

R. D

ISC

ON

NE

CT

GR

AY F

LAT

WIR

E F

RO

M C

IRC

UIT

BO

AR

D A

ND

RE

-CO

NN

EC

T. S

EN

SO

RS

HO

ULD

FLA

SH

FO

R 5

SE

CO

ND

S.

DO

ES

IT F

LAS

H?

TES

T S

EN

SO

R. D

ISC

ON

NE

CT

GR

AY F

LAT

WIR

E F

RO

MC

IRC

UIT

BO

AR

D A

ND

RE

-CO

NN

EC

T.S

EN

SO

R S

HO

ULD

FLA

SH

FO

R 5

SE

CO

ND

S. D

OE

S IT

FLA

SH

?

CLO

SE

STO

P V

ALV

E,

RE

PLA

CE

SO

LEN

OID

KIT

.R

E-A

SS

EM

BLE

& IN

STA

LL U

NIT

.O

PE

N S

TOP

VA

LVE

.

BA

TTE

RY

LO

W;

RE

PLA

CE

BA

TTE

RY

SEE

STEP

13,

pag

e 10

in m

anua

l

NO

NO

YE

S

DO

ES

TH

E S

EN

SO

R F

LAS

HFO

R T

HE

FIR

ST

5 S

EC

ON

DS

?

NO

RE

PLA

CE

SO

LEN

OID

KIT

RE

TRY

AU

TOM

ATI

C F

LUS

H;

WA

S IT

SU

CC

ES

SFU

L?

YE

S

1. C

OV

ER

SE

NS

OR

FO

R 1

0 S

EC

ON

DS

2. U

NC

OV

ER

SE

NS

OR

FO

R 1

0 S

EC

ON

DS

.

RE

PLA

CE

BA

TTE

RY

SEE

STEP

13,

pag

e 10

in m

anua

l

MA

NU

AL

VALV

EO

BS

TRU

CTE

D.

CLO

SE

STO

P V

ALV

EA

ND

SE

RV

ICE

RE

TRY

AU

TO F

LUS

H

NO

UN

IT IS

CO

NTI

NU

OU

SLY

FLU

SH

ING

PU

SH

MA

NU

AL

FLU

SH

BU

TTO

N; D

OE

S IT

RE

TUR

N?

LOO

K F

OR

RE

PE

ATE

DD

OU

BLE

FLA

SH

ON

SE

NS

OR

NO

NO

YE

S

NO

1. C

OV

ER

SE

NS

OR

FO

R 1

0 S

EC

ON

DS

2. U

NC

OV

ER

SE

NS

OR

FO

R 1

0 S

EC

ON

DS

.

DO

ES

TH

E U

NIT

STO

P F

LUS

HIN

G?

YE

S

INS

TALL

NE

W B

ATT

ER

YSE

E ST

EP 1

3, p

age

10in

man

ual

YE

S

1. C

LOS

E S

TOP

VA

LVE

,2.

RE

PLA

CE

SO

LEN

OID

KIT

.3.

RE

-AS

SE

MB

LE A

ND

INS

TALL

UN

IT.

4. O

PE

N S

TOP

VA

LVE

.

RE

PLA

CE

SE

NS

OR

NO

TROU

BLES

HOOT

ING FL

OW CH

ARTS

UN

IT D

OE

S N

OT

FLU

SH

AT

ALL

HOT

LIN

E FO

R H

ELP

For

toll-fr

ee in

form

atio

n an

d an

swer

s to

you

r qu

estio

ns,

call:

1 (8

00

) 4

42

-19

02

Wee

kday

s 8

:00

a.m

. to

6:0

0 p

.m.

EST

IN C

AN

AD

A

1-8

00

-38

7-0

36

9

(TO

RON

TO 1

-90

5-3

06

-10

93

)W

eekd

ays

8:0

0 a

.m.

to 7

:00

p.m

. ES

T

Pro

duct

nam

es

liste

d h

ere

in a

re t

radem

ark

s of

AS

Am

eri

ca,

Inc.

IN M

EXIC

O

01

-80

0-8

39

-12

-00

M968547 REV. 1.3